NexusData GA0002 User Manual Installation and

NexusData Ltd. Installation and

Installation and User Manual

Nexus Data Industrial AMR UnitInstallation and Initialization ManualGeneralIn order to comply with FCC RF Exposure requirements, the AMR unitmust be installed in such a way that there is a 20 c”m separation distancebetween it and all persons during normal operation.Assembly1. Break seals.2. Dismantle index cover, from meter (releasing 2 screws).3. Dismantle old index, from meter (releasing 2 screws).4. Dispose all old screws.5. Connect index to AMR unit with 2 short screws, aligning the AMRunit’s shaft to the index’s shaft.6. Place the AMR unit on the meter top, its label facing the front, andalign its shaft with the meter shaft. By slightly rotating the shaft of theindex, check that motion is transferred and that shafts are not stuck.7. Holding the AMR unit’s position, place the index cover on top andassemble 2 long screws in index cover. The screws should fit throughthe AMR unit and into meter.8. Tighten screws and seal with the red plastic seals.9. Initialize the AMR unit using the MINT (handheld programmer):9.1. Press 1 for WO (work order) by route to initializing the first AMRunit.1. WO by route2. Add WO3. Read TX4. Program TX
9.2.  Select the Work Order and verify the details. Then key ENTER.   9.3. Select ‘4. CCF Reading’ and enter the number appearing on theindex.    9.4. Press on the program key to initialize the AMR unit.WO: nnn/xxx >    (APP)Loc: [decodedMeterLocation]Address: [first 63characters of address]Meter: xxxyyyzzz 1. No. of Dials: 4 2. Index Drive: 1 3. Index Pressure: LP 4. CCF Reading: _