Nexus Data Industrial AMR UnitInstallation and Initialization ManualGeneralIn order to comply with FCC RF Exposure requirements, the AMR unitmust be installed in such a way that there is a 20 c”m separation distancebetween it and all persons during normal operation.Installation Tasks1. Remove index from gas meter.2. Mount AMR transmitter on gas meter.3. Install index onto AMR transmitter.4. Initialize AMR transmitter with HHT.Assembly1. Break seals.2. Dismantle index (releasing 4 screws).3. Dispose all old screws.4. Attached index to AMR, aligning the AMR unit’s shaft to the index’sshaft.5. Place the AMR unit on the meter top, its label facing the front, andalign its shaft with the meter shaft. By slightly rotating the shaft of theindex, check that motion is transferred and that shafts are not stuck.6. Holding the AMR unit’s position, assemble 4 long screws in index.The screws should fit through the AMR unit and into meter.7. Tighten screws and seal with the red plastic seals.
8. Initialize the AMR unit using the MINT (handheld programmer):8.1. Press 1 for WO (work order) by route to initializing the first AMRunit.8.2.  Select the Work Order and verify the details. Then key ENTER.   8.3. Select ‘4. CCF Reading’ and enter the number appearing on theindex.    8.4. Press on the program key to initialize the AMR unit.1. WO by route2. Add WO3. Read TX4. Program TXWO: nnn/xxx >    (APP)Loc: [decodedMeterLocation]Address: [first 63characters of address]Meter: xxxyyyzzz 1. No. of Dials: 4 2. Index Drive: 1 3. Index Pressure: LP 4. CCF Reading: _