Nihon Kohden ZM-930PA WMTS TRANSMITTER User Manual Cover2 ZM920PA 930PA OM A pmd
Nihon Kohden Corporation WMTS TRANSMITTER Cover2 ZM920PA 930PA OM A pmd
Contents
- 1. Users Manual
- 2. User Manual
User Manual
TRANSMITTER ZM-920PA/930PA If you have any comments or suggestions on this manual, please contact us at: www.nihonkohden.com 0614-007205A Contents GENERAL HANDLING PRECAUTIONS ......................................... i WARRANTY POLICY .................................................................... iii EMC RELATED CAUTION ............................................................. v Conventions Used in this Manual and Instrument ....................... vii Warnings, Cautions and Notes ............................................... vii Explanations of the Symbols in this Manual and Instrument viii Introduction ......................................................................................... 1 Panel Description ............................................................................... 3 Top Panel ...................................................................................... 3 Front Panel .................................................................................... 4 ZM-920PA ................................................................................ 4 ZM-930PA ................................................................................ 5 Important Safety Information .............................................................. 6 General ......................................................................................... 6 Battery ........................................................................................... 8 Transmitter Channel Management ............................................... 8 For Patients Using Implantable Pacemaker ................................. 9 Output Signal ................................................................................ 9 ECG Monitoring .......................................................................... 10 SpO2 Monitoring .......................................................................... 10 Maintenance ............................................................................... 13 Preparation ....................................................................................... 14 Installing (Replacing) Batteries .................................................. 14 Procedure .............................................................................. 15 WARNING and CAUTION for Battery Handling .......................... 15 Situations Requiring Battery Replacement ................................ 16 Attaching a Strap to the Transmitter ............................................ 16 Turning On/Off the Transmitter .................................................... 17 Check Items Before Turning On the Power ........................... 17 Turning On/Off the Power ...................................................... 17 Operator's Manual ZM-920PA/930PA Check Items After Turning On the Power ............................... 17 Check Items After the Power Off ............................................ 18 ECG Monitoring ................................................................................ 19 ECG Measurement Procedure ................................................... 20 Selecting Electrode Lead and Disposable Electrode ................ 21 Option .................................................................................... 21 Connecting the Electrode Lead to the Transmitter ..................... 22 Selecting the Electrode Position ................................................. 22 Six Electrodes ....................................................................... 23 When Using 4 to 6 DIN Type Leads to Monitor 6 Lead ECG 24 Three Electrodes ................................................................... 25 Connecting the Electrode Lead and Disposable Electrodes ..... 26 Preparing the Patient Skin .................................................... 26 Attaching Electrodes to the Patient ....................................... 26 Detection and Display of Measurement Condition .................... 27 Electrode Detachment .......................................................... 27 Respiration Monitoring ..................................................................... 28 Respiration Measurement Procedure ........................................ 29 Electrode Position for Respiration Monitoring ............................ 29 Electrode Position Examples ................................................ 29 SpO2 Monitoring ............................................................................... 31 Measurement Procedure ............................................................ 33 Selecting SpO2 Probe ................................................................. 33 Reusable Probes .................................................................. 34 Disposable Probes ................................................................ 35 Connecting SpO2 Probe to the Transmitter ................................. 38 Attaching the Probe to the Patient .............................................. 39 Starting Measurement ................................................................ 40 Turning SpO2 Data and Pulse Level Bar Graph Display On/Off . 41 Detecting and Displaying Measurement Condition ................... 41 External Light Noise Alarm ................................................... 41 Insufficient Light Alarm .......................................................... 42 Probe Malfunction Alarm ....................................................... 42 When Measurement Condition is Unstable .......................... 42 Alarm List .......................................................................................... 43 Troubleshooting ................................................................................ 45 ii Operator's Manual ZM-920PA/930PA Changing the Transmitter Channel .................................................. 47 Lifetime and Disposal ....................................................................... 48 Disposing of Used Batteries ....................................................... 48 Replacement ......................................................................... 48 Disposal ................................................................................ 48 Disposing of Electrodes and SpO2 Probes ................................. 48 Cleaning, Disinfection and Sterilization ........................................... 49 Transmitter and Electrode Lead ................................................. 49 Cleaning ................................................................................ 49 Disinfection ............................................................................ 49 SpO2 Probe ................................................................................. 50 Replacing the Battery Case Cover ................................................... 51 Repair Parts Availability Policy ......................................................... 51 Specifications ................................................................................... 52 ECG measurement ................................................................ 52 Respiration measurement .................................................... 52 SpO2 measurement ............................................................... 52 Transmitter ............................................................................. 52 Safety standards ................................................................... 53 Water resistance ................................................................... 54 Power requirements .............................................................. 54 Environment .......................................................................... 54 Dimension and Weight .......................................................... 54 Standard Accessories ...................................................................... 55 Options ............................................................................................. 56 ECG/RESP ............................................................................ 56 SpO2 ...................................................................................... 57 Operator's Manual ZM-920PA/930PA iii GENERAL HANDLING PRECAUTIONS This device is intended for use only by qualified medical personnel. Use only Nihon Kohden approved products with this device. Use of non-approved products or in a non-approved manner may affect the performance specifications of the device. This includes, but is not limited to, batteries, recording paper, pens, extension cables, electrode leads, input boxes and AC power. Please read these precautions thoroughly before attempting to operate the instrument. 1. To safely and effectively use the instrument, its operation must be fully understood. 2. When installing or storing the instrument, take the following precautions: (1) Avoid moisture or contact with water, extreme atmospheric pressure, excessive humidity and temperatures, poorly ventilated areas, and dust, saline or sulphuric air. (2) Place the instrument on an even, level floor. Avoid vibration and mechanical shock, even during transport. (3) Avoid placing in an area where chemicals are stored or where there is danger of gas leakage. (4) The power line source to be applied to the instrument must correspond in frequency and voltage to product specifications, and have sufficient current capacity. (5) Choose a room where a proper grounding facility is available. 3. Before Operation (1) Check that the instrument is in perfect operating order. (2) Check that the instrument is grounded properly. (3) Check that all cords are connected properly. (4) Pay extra attention when the instrument is in combination with other instruments to avoid misdiagnosis or other problems. Operator's Manual ZM-920PA/930PA (5) All circuitry used for direct patient connection must be doubly checked. (6) Check that battery level is acceptable and battery condition is good when using battery-operated models. 4. During Operation (1) Both the instrument and the patient must receive continual, careful attention. (2) Turn power off or remove electrodes and/or transducers when necessary to assure the patient’s safety. (3) Avoid direct contact between the instrument housing and the patient. 5. To Shutdown After Use (1) Turn power off with all controls returned to their original positions. (2) Remove the cords gently; do not use force to remove them. (3) Clean the instrument together with all accessories for their next use. 6. The instrument must receive expert, professional attention for maintenance and repairs. When the instrument is not functioning properly, it should be clearly marked to avoid operation while it is out of order. 7. The instrument must not be altered or modified in any way. 8. Maintenance and Inspection: (1) The instrument and parts must undergo regular maintenance inspection at least every 6 months. (2) If stored for extended periods without being used, make sure prior to operation that the instrument is in perfect operating condition. (3) Technical information such as parts list, descriptions, calibration instructions or other information is available for qualified user technical personnel upon request from your Nihon Kohden representative. ii Operator's Manual ZM-920PA/930PA 9. When the instrument is used with an electrosurgical instrument, pay careful attention to the application and/or location of electrodes and/or transducers to avoid possible burn to the patient. 10. When the instrument is used with a defibrillator, make sure that the instrument is protected against defibrillator discharge. If not, remove patient cables and/or transducers from the instrument to avoid possible damage. WARRANTY POLICY Nihon Kohden Corporation (NKC) shall warrant its products against all defects in materials and workmanship for one year from the date of delivery. However, consumable materials such as recording paper, ink, stylus and battery are excluded from the warranty. NKC or its authorized agents will repair or replace any products which prove to be defective during the warranty period, provided these products are used as prescribed by the operating instructions given in the operator’s and service manuals. No other party is authorized to make any warranty or assume liability for NKC’s products. NKC will not recognize any other warranty, either implied or in writing. In addition, service, technical modification or any other product change performed by someone other than NKC or its authorized agents without prior consent of NKC may be cause for voiding this warranty. Defective products or parts must be returned to NKC or its authorized agents, along with an explanation of the failure. Shipping costs must be prepaid. This warranty does not apply to products that have been modified, disassembled, reinstalled or repaired without Nihon Kohden approval or which have been subjected to neglect or accident, damage due to accident, Operator's Manual ZM-920PA/930PA iii fire, lightning, vandalism, water or other casualty, improper installation or application, or on which the original identification marks have been removed. In the USA and Canada other warranty policies may apply. CAUTION United States law restricts this device to sale by or on the order of a physician. Equipment Authorization Requirement Operation of this equipment requires the prior coordination with a frequency coordinator designated by the FCC for the Wireless Medical Telemetry Service. iv Operator's Manual ZM-920PA/930PA EMC RELATED CAUTION This equipment and/or system complies with the International Standard IEC60601-1-2 for electromagnetic compatibility for medical electrical equipment and/or system. However, an electromagnetic environment that exceeds the limits or levels stipulated in the IEC60601-1-2, can cause harmful interference to the equipment and/or system or cause the equipment and/or system to fail to perform its intended function or degrade its intended performance. Therefore, during the operation of the equipment and/or system, if there is any undesired deviation from its intended operational performance, you must avoid, identify and resolve the adverse electromagnetic effect before continuing to use the equipment and/or system. The following describes some common interference sources and remedial actions: 1. Strong electromagnetic interference from a nearby emitter source such as an authorized radio station or cellular phone: Install the equipment and/or system at another location if it is interfered with by an emitter source such as an authorized radio station. Keep the emitter source such as cellular phone away from the equipment and/or system. 2.Effect of direct or indirect electrostatic discharge: Make sure all users and patients in contact with the equipment and/or system are free from direct or indirect electrostatic energy before using it. A humid room can help lessen this problem. 3.Electromagnetic interference with any radio wave receiver such as radio or television: If the equipment and/or system interferes with any radio wave receiver, locate the equipment and/or system as far as possible from the radio wave receiver. Operator's Manual ZM-920PA/930PA If the above suggested remedial actions do not solve the problem, consult your Nihon Kohden representative for additional suggestions. vi Operator's Manual ZM-920PA/930PA Conventions Used in this Manual and Instrument Warnings, Cautions and Notes Warnings, cautions and notes are used in this manual to alert or signal the reader to specific information. WARNING A warning alerts the user to the possible injury or death associated with the use or misuse of the instrument. CAUTION A caution alerts the user to possible injury or problems with the instrument associated with its use or misuse such as instrument malfunction, instrument failure, damage to the instrument, or damage to other property. NOTE A note provides specific information, in the form of recommendations, prerequirements, alternative methods or supplemental information. Operator's Manual ZM-920PA/930PA vii Explanations of the Symbols in this Manual and Instrument The following symbols found in this manual/instrument bear the respective descriptions as given. Symbol Description Power On Symbol Description Attention, consult operator’s manual Power Off Nurse call Defibrillation proof type BF applied part Replace battery Defibrillation proof type CF applied part Check electrode Direct current viii Operator's Manual ZM-920PA/930PA Introduction The ZM-920PA/930PA transmitter transmits ECG and other data from a patient to a Nihon Kohden monitor for continuous monitoring. Available parameters and functions vary between the models. Read the operator’s manual for the monitor before operation. Model Parameters ZM-920PA • ECG • Impedance respiration ZM-930PA • ECG • Impedance respiration • SpO2 Functions The following information is indicated by LED. • Check ECG electrodes • Replace batteries The following information is indicated on LCD. • SpO2 value • Pulse wave amplitude • Replace batteries The following information is indicated by LED. • Check ECG electrodes The transmitter channel can be changed by the QI-901PK Channel Writer. To change the channel number, refer to the channel writer manual. WARNING The following actions must be taken to properly receive the transmitter signal of the correct patient on the receiving instrument, otherwise, there may be signal loss or signals may mix causing a serious accident, such as monitoring a different patient. • Assign a channel administrator in the hospital and only he or she should manage channel assignments. • The channel administrator must manage the channels in the facility so that there is no signal interference. • When the transmitter channel is changed, the channel administrator must check that the channel on the receiving monitor is also changed and the signal is properly received. Operator's Manual ZM-920PA/930PA • The channel administrator must replace the channel number label on the transmitter with the new one after changing the channel. CAUTION • Do not use the same channel for different patients. If the same channel is used for two patients, the two patients’ data will be lost due to mutual modulation interference, or another patient’s data may appear on the receiving monitor screen. • Do not use transmitters of adjacent channels in a hospital. If a transmitter of an adjacent channel is used, radio waves from one transmitter affects the receiver of the adjacent channel’s transmitter and there may be interference. • Do not use the same transmitter on more than one patient at the same time. Do not connect different sensors on different patients to the same transmitter. NOTE • To prevent interference between channels, assign a channel administrator in the hospital and only he or she should manage channel assignment. • Use Nihon Kohden parts and accessories to assure maximum performance from your instrument. • For stable signal reception, it is recommended to use a diversity antenna system on the receiving monitor. Otherwise, spike noise from transient fading of electric field strength (for example, people moving) may interfere with the transmitter signal and may be mistaken as an arrhythmia on the receiving monitor. • For details on the receiving monitor and upgrade information, contact your Nihon Kohden representative. Operator's Manual ZM-920PA/930PA Panel Description Top Panel For attaching a strap ZM-930PA only SpO2 socket Connects to the SpO2 probe. Refer to the warnings below Refer to the symbol page Refer to the symbol page Refer to the warnings below ECG/RESP socket Connects to the electrode lead for measuring ECG and/or respiration by the impedance method. WARNING • Before defibrillation, check that the electrode leads and SpO2 probe attached to the patient are properly connected to the transmitter. Touching the metal parts of disconnected leads and probes may cause electrical shock or injury by discharged energy. • When performing defibrillation, discharge as far as possible from electrodes, patches and any gel, cream or medicine on the chest of the patient. If there is a possibility that the defibrillator paddle could touch these materials, remove them from the patient. If the defibrillator paddle directly contacts these materials, the discharged energy may cause skin burn to the patient. • Before defibrillation, all persons must keep clear of the bed and must not touch the patient or any equipment connected to the patient. Failure to follow this warning may cause electrical shock or injury. Operator's Manual ZM-920PA/930PA Front Panel ZM-920PA Power switch Turns transmitter power on or off. Replace batteries LED Lights when the batteries need replacement. RA LA LL Va Vb Check electrodes LED Lights when the electrode is detached from the patient. USAch 9002 608.025 MHz CALL key When this key is pressed, a "peep" sounds at the transmitter, and "CALL" message appears at the monitor. Depending on the settings on the monitor, an ECG waveform is recorded when this key is pressed. Channel lable Refer to the warning below. Battery case Contains two 1.5 V dry cell batteries (AA). WARNING Close the battery case cover during operation. If the transmitter is used with the battery case cover open, anyone who touches the opened battery case may receive an electrical shock when defibrillation is performed. Touching the opened battery case may cause electrostatic discharge and intermittently interfere with the waveform or data. CAUTION Only use your finger to press the CALL key. Do not press the key with a sharp object, otherwise the key may be damaged. Operator's Manual ZM-920PA/930PA ZM-930PA For the descriptions except for the LCD, refer to the “ZM-920PA” section on the previous page. RA LA LL Va Vb USAch 9002 608.025 MHz LCD Battery replacement mark: Appears when the batteries are weak. Immediately replace the batteries when this appears. %SpO2: Displayed when the power is turned on. This indication is not displayed when SpO2 display is turned off. Pulse level bar graph: Displays pulse level in 7 steps. SpO2 data: Displays SpO2 data. When SpO2 is 41 to 100%, the value is displayed. (ex. ) When SpO2 is under 40%, “ ” is displayed. When the detected pulse is too small to measure, “ ” is displayed. Operator's Manual ZM-920PA/930PA Important Safety Information General WARNING • Never use the transmitter in the presence of any flammable anesthetic gas or high concentration oxygen atmosphere. Failure to follow this warning may cause explosion or fire. • Never use the transmitter in a hyperbaric oxygen chamber. Failure to follow this warning may cause explosion or fire. • Never take this transmitter into an MRI test room. • When performing MRI test, remove all electrodes from the patient which are connected to this instrument. Failure to follow this warning may cause skin burn on the patient. For details, refer to the MRI manual. • Before defibrillation, check that the electrode leads and SpO2 probe attached to the patient are properly connected to the transmitter. Touching the metal parts of disconnected leads and probes may cause electrical shock or injury by discharged energy. • When performing defibrillation, discharge as far as possible from electrodes, patches and any gel, cream or medicine on the chest of the patient. If there is a possibility that the defibrillator paddle could touch these materials, remove them from the patient. If the defibrillator paddle directly contacts these materials, the discharged energy may cause skin burn to the patient. • Before defibrillation, all persons must keep clear of the bed and must not touch the patient or any equipment connected to the patient. Failure to follow this warning may cause electrical shock or injury. • When the transmitter is used with an electrosurgical unit (ESU), firmly attach the entire area of the ESU return plate. Otherwise, the current from the ESU flows into the electrodes of the transmitter, causing electrical burn where the electrodes are attached. For details, refer to the ESU manual. Operator's Manual ZM-920PA/930PA • Close the battery case cover during operation. If the transmitter is used with the battery case cover open, anyone who touches the opened battery case may receive an electrical shock when defibrillation is performed. Touching the opened battery case may cause electrostatic discharge and intermittently interfere with the waveform or data. CAUTION • Only use Nihon Kohden specified electrodes, electrode leads and SpO2 probes. Otherwise, the maximum performance from the instrument cannot be guaranteed. • Do not reuse disposable items. • Do not shake or swing the transmitter while holding the leads or cables connected to the transmitter. The transmitter may come off and injure someone or damage surrounding instruments. • Attach a strap to the transmitter to prevent the transmitter from falling. • Turn off the power of mobile phones, small wireless devices and other devices which produce strong electromagnetic interference around a patient (except for devices allowed by the hospital administrator). Radio waves from devices such as mobile phones or small wireless devices may be mistaken as respiration or pulse waves and the displayed data may be incorrect. • Do not use the same channel for different patients. If the same channel is used for two patients, the two patients’ data will be lost due to mutual modulation interference, or another patient’s data may appear on the receiving monitor screen. • Do not use transmitters of adjacent channels in a hospital. If a transmitter of an adjacent channel is used, radio waves from one transmitter affects the receiver of the adjacent channel’s transmitter and there may be interference. Operator's Manual ZM-920PA/930PA Battery WARNING • Keep the battery pack away from fire. It may explode. • Do not damage, disassemble, drop or give impact to the battery. If the battery is damaged and substance inside the battery contacts the skin or clothes, wash immediately and thoroughly with water. • Never short-circuit the + and – terminals on the battery. It may cause overheating and fire. • Take care that the patient does not swallow batteries. CAUTION • Battery replacement must be performed by the operator. When replacing batteries of the transmitter currently used for a patient, disconnect electrode leads from the transmitter before replacing batteries or do not touch the patient during replacement. • The battery charger must be used outside the patient environment. • Refer to the battery and battery charger manuals for details on handling the batteries. Transmitter Channel Management WARNING The following actions must be taken to properly receive the transmitter signal of the correct patient on the receiving instrument, otherwise, there may be signal loss or signals may mix causing a serious accident, such as monitoring a different patient. • Assign a channel administrator in the hospital and only he or she should manage channel assignments. • The channel administrator must manage the channels in the facility so that there is no signal interference. • When the transmitter channel is changed, the channel administrator must check that the channel on the receiving monitor is also changed and the signal is properly received. Operator's Manual ZM-920PA/930PA • The channel administrator must replace the channel number label on the transmitter with the new one after changing the channel. For Patients Using Implantable Pacemaker WARNING Interaction Between Minute Ventilation Rate-Adaptive Pacemakers and Cardiac Monitoring and Diagnostic Equipment. The bioelectric impedance measurement sensor of a minute ventilation rate-adaptive implantable pacemaker, may be affected by the transmitter which is connected to the same patient. If this occurs, the pacemaker may pace at its maximum rate and the transmitter may give incorrect data to the monitor. If this occurs, disconnect the electrode leads from the patient or change the setting on the pacemaker by referring to the pacemaker’s manual. For more details, contact your pacemaker distributor or Nihon Kohden representative. Output Signal CAUTION Do not use the output signal from the receiving monitor as the synchronization signal for other equipment such as IABP, MRI, echocardiography or defibrillator, there may be time delay between the monitor and the other equipment caused by waveform transmission delay and spike noise may interfere on the output signal and be mistaken as a trigger. Operator's Manual ZM-920PA/930PA ECG Monitoring CAUTION • Only use Nihon Kohden specified electrodes and electrode leads. When other type of electrodes or electrode leads are used, the “CHECK ELECTRODE” message may be displayed and monitoring may stop. • When the “ELECTRODE OFF” or “CHECK ELECTRODE” message is displayed on the receiving monitor, ECG is not monitored properly and the ECG alarm does not function. Check the electrode and electrode leads, and if necessary, replace with new ones. SpO2 Monitoring WARNING • SpO2 measurement may be incorrect in the following cases. • When the patient’s carboxyhemoglobin or methemoglobin increases abnormally. • When dye is injected in the blood. • When using an electrosurgical unit. • During CPR. • When measuring at a site with venous pulse. • When there is body movement. • When the pulse wave is small (insufficient peripheral circulation). • Check the circulation condition by observing the skin color of the measuring site and pulse waveform. Change the measuring site every 8 hours for disposable probes and every 4 hours for reusable probes. The skin temperature may increase at the attached site by 2 or 3°C (4 or 5°F) and cause a burn or pressure necrosis. When using the probe on the following patients, take extreme care and change the measurement site more frequently according to symptoms and degree. • A patient with a fever 10 Operator's Manual ZM-920PA/930PA • A patient with peripheral circulation insufficiency • Neonate or low birth weight infant with delicate skin • When not monitoring SpO2, disconnect the SpO2 cable from the transmitter. Otherwise, noise from the probe sensor may interfere and incorrect data is displayed on the screen. • When using the TL-201T finger probe, do not fasten the probe and cable to the finger by wrapping with tape. This may cause burn, congestion or pressure necrosis from poor blood circulation. • When using probes other than the TL-201T finger probe, to avoid poor circulation, do not wrap the tape too tight. Check the blood circulation condition by observing the skin color and congestion at the skin peripheral to the probe attachment site. Even for shortterm monitoring, there may be burn or pressure necrosis from poor blood circulation, especially on neonates or low birth weight infants whose skin is delicate. Accurate measurement cannot be performed on a site with poor peripheral circulation. CAUTION • NIBP and SpO2 can be measured on the same limb, but the SpO2 monitoring may not be accurate during NIBP measurement. Be careful when reading the SpO2 values. • While a patient is on medication which causes vasodilation, the pulse waveform may change and in rare cases the SpO2 value may not be displayed. • Normal external light does not affect monitoring but strong light such as a surgical light or sunlight may affect monitoring. If affected, cover the measuring site with a blanket. • If the attachment site is dirty with blood or bodily fluids, clean the attachment site before attaching the probe. If there is nail polish on the attachment site, remove the polish. Otherwise, the amount of transmitted light decreases, and measured value may be incorrect or measurement cannot be performed. • The disposable probe is not sterilized. Use the disposable probe only for a single patient. Never reuse the disposable probe for another patient because it causes cross infection. Operator's Manual ZM-920PA/930PA 11 • Do not use a probe that is deteriorated by aging. Accurate measurement cannot be performed. • Do not use damaged or disassembled probe. It causes incorrect measurement and may injure the patient. • If the skin gets irritated or redness appears on the skin from the probe, change the attachment site or stop using the probe. Take extreme care for the patients with delicate skin. • Do not pull or bend the probe cable, and do not put caster feet on the probe cable. Do not immerse the probe cable in chemical solutions or water. Failure to follow these instructions may cause cable discontinuity, short circuit, skin burn on the patient and incorrect measurement data. Replace any broken probe with a new one. • When the probe is attached on an appropriate site with sufficient circulation and the error message confirming the probe attachment repeatedly appears, the probe may be deteriorated. Replace it with a new one. • When a message indicates a faulty SpO2 probe, stop monitoring and replace the probe with a new one. • When removing a probe that is taped to the skin, do not pull the probe cable because this can damage the cable. • Neonatal skin is delicate. Remove the probe and tape carefully and slowly. • Do not immerse the disposable probe in detergents or water. If the probe adhesive surface gets wet, adhesiveness becomes weak and the probe cannot be attached to the skin. • Before using the TL-260T multi-site Y probe, be sure to attach the probe to the sponge attachment tape S or L. Do not use the probe without the sponge attachment tape attached. Using the probe without the sponge attachment tape causes incorrect measurement and may injure the skin at the attachment site. • When fixing the TL-260T multi-site Y probe with the sponge attachment tape, confirm that the adhesive part of the tape is not on the skin. The adhesive may cause oversensitive symptoms on the skin such as redness or itch. If the adhesive touches the skin, remove it carefully and slowly because neonatal skin is very delicate. 12 Operator's Manual ZM-920PA/930PA • Do not use a dirty sponge attachment tape. The measurement value may be incorrect. • When removing the probe from the attachment tape, do not pull the sensor cable because this can damage the cable. • Use the sponge attachment tape S and L only with the specified products. • Refer to the probe instruction manual for details. • When any of the following occurs, the probe may be broken. Replace it with a new one and check the probe. • The transmitter generates “pip” sound every 0.25 seconds. • SpO2 data is 85% and blinking. Maintenance WARNING If detergents or dirty liquid spills into the transmitter, clean it and dry it completely before use. If the wet transmitter is used, the patient or anyone in contact with the transmitter may receive an electric shock. CAUTION Never disassemble or repair the transmitter. When there is any problem with the transmitter after maintenance and inspection, contact your Nihon Kohden representative. Operator's Manual ZM-920PA/930PA 13 Preparation Installing (Replacing) Batteries Use two AA(R6) type alkaline dry cell batteries, manganese dry cell batteries, NiCd rechargeable batteries or NiMH batteries. With new alkaline batteries, the transmitter can continuously measure ECG, respiration and SpO2 for approximately 3 days or ECG and respiration for approximately 4 days. Operation time depends on the thickness of SpO2 probe attachment site. NOTE The capacity of manganese, NiCd and NiMH batteries is less than that of alkaline batteries, therefore the lifetime of the battery is shorter. Type Manganese NiCd NiMH Lifetime About 1/2 of alkaline batteries About 1/3 of alkaline batteries (when fully charged) About 1/2 of alkaline batteries (when fully charged) CAUTION Battery replacement must be performed by the operator. When replacing batteries of the transmitter currently used for a patient, disconnect electrode leads from the transmitter before replacing batteries, or do not touch the patient during replacement. If electrode leads are attached to the patient and the person replacing the batteries touches the patient, the patient leakage current over the amount allowed may occur. CAUTION • Replace both batteries at the same time. • Do not use different types of batteries together. 14 Operator's Manual ZM-920PA/930PA NOTE + and − Insert the batteries with the correct polarity (+ −). Procedure 1. Open the battery case cover. 2. Insert two dry cell batteries (LR6) into the battery case observing the correct polarity. 3. Close the cover and press it gently until it clicks. WARNING and CAUTION for Battery Handling WARNING • Keep the battery pack away from fire. It may explode. • Do not damage, disassemble, drop or give impact to the battery. If the battery is damaged and substance inside the battery contacts the skin or clothes, wash immediately and thoroughly with water. • Never short-circuit the + and – terminals on the battery. It may cause overheating and fire. • Take care that the patient does not swallow batteries. CAUTION When the transmitter is not in use, remove batteries or turn the power OFF. With the power ON, battery power is consumed even if measurement is not performed. The batteries may become unusable from overdischarge, and leakage from the battery may damage the transmitter. Operator's Manual ZM-920PA/930PA 15 NOTE • When using rechargeable NiCd batteries or NiMH batteries, shallow charging/discharging shortens battery capacity. For details, refer to the battery operator’s manual. • Remove the batteries from the transmitter before disposing of the transmitter. Situations Requiring Battery Replacement Replace the batteries when any of the following occurs. • The “ ” LED lights (ZM-920PA) or the “ ” mark is displayed on the LCD (ZM-930PA) on the transmitter. • The transmitter generates a constant alarm (continuous “peep” sound). • The monitor displays the battery replacement message on the screen. • When the power of the LCD transmitter is turned on, no message or icon is displayed. (Only the ZM-930PA). Attaching a Strap to the Transmitter To open the clip, firmly pull out the tab in direction of the arrow. NOTE • Attach a strap to the transmitter to prevent the transmitter from falling. • Do not attach the clip to hard objects such as thick cloths or zippers, or the clip may break. Attach a strap to the transmitter and fasten the clip to the patients’ clothes or bed sheets. If the transmitter falls off, the battery cover may be opened. If the patient touches the terminals of the batteries, patient leakage current over the allowable amount can occur. 16 Operator's Manual ZM-920PA/930PA Turning On/Off the Transmitter Check Items Before Turning On the Power To use the instrument in a safe and optimum condition, before turning on the transmitter power switch, check the following. Appearance • There is no damage or dirt on the outside of the transmitter. (Power switch, LED, LCD, CALL key, junction, battery case cover, battery case, etc.) • The transmitter is completely dry. • The electrode lead is not broken. • There is no damage or dirt on the SpO2 probe or on the disposable electrodes. Battery • The battery polarity is correct. • The battery case spring is firmly fixed and the battery is not loose. • The battery case cover is firmly closed. Channel Setting • The transmitter channel corresponds to those of the receiving monitor. • The same channel is not being used on a different transmitter in the surrounding area. Turning On/Off the Power ON To turn on the power, turn the power switch to the right. After a “peep” sound for about one second, the power is turned on. (There is no “peep” sound when the “ ” LED light or the “ ” are blinking on the LCD). OFF To turn off the power, turn the power switch to the left. Check Items After Turning On the Power After turning on the power, check the following items. Power On • The power switch is not damaged. • The transmitter generates a “peep” sound for about one second. Operator's Manual ZM-920PA/930PA 17 • • • • • All LEDs light and values are displayed on the LCD for about one second. The transmitter does not generate a continuous “pip” sound. The transmitter does not liberate excessive heat. The “ ” LED does not light or the “ ” mark is not displayed on the LCD. The transmitter does not interfere with the operation of medical instruments used near it. Basic Operation • The “signal loss” message is not displayed on the monitor when the transmitter is inside the receiving range of the monitor. • A “peep” sounds at the transmitter and “CALL” message appears at the receiving monitor when the CALL key is pressed and the transmitter is inside the receiving range of the monitor. • The battery replacement message is not displayed on the monitor. Check Items After the Power Off • ECG electrode leads and SpO2 probe are cleaned and disinfected. • When the transmitter gets wet, liquid is wiped off and the transmitter is thoroughly dried. • There are enough consumables, such as disposable electrodes. • The power is turned off. • The batteries are removed from the transmitter when it will not be used for a long time. • Dead batteries are disposed of properly. 18 Operator's Manual ZM-920PA/930PA ECG Monitoring When 6 leads are used on this transmitter, up to 8 lead (I, II, III, aVR, aVL, aVF, Va and Vb) of ECG waveforms can be displayed on the receiving monitor. The heart rate is also measured. When 3 leads are used, one channel ECG waveform of lead II can be displayed on the receiving monitor. Refer to the operator’s manual of the monitor for details. WARNING Interaction Between Minute Ventilation Rate-Adaptive Pacemakers and Cardiac Monitoring and Diagnostic Equipment* The bioelectric impedance measurement sensor of a minute ventilation rate-adaptive implantable pacemaker may be affected by the transmitter which is connected to the same patient. If this occurs, the pacemaker may pace at its maximum rate and the transmitter may give incorrect data to the monitor. If this occurs, disconnect the electrode leads from the patient or change the setting on the pacemaker by referring to the pacemaker’s manual. For more details, contact your pacemaker distributor or Nihon Kohden representative. * Minute ventilation is sensed in rate-adaptive pacemakers by a technology known as bioelectric impedance measurement (BIM). Many medical devices in addition to pacemakers use this technology. When one of these devices is used on a patient with an active, minute ventilation rate-adaptive pacemaker, the pacemaker may erroneously interpret the mixture of BIM signals created in the patient, resulting in an elevated pacing rate. For more information, see the FDA web site. http://www.fda.gov/cdrh/safety.html Operator's Manual ZM-920PA/930PA 19 WARNING When the transmitter is used with an electrosurgical unit (ESU), firmly attach the entire area of the ESU return plate. Otherwise, the current from the ESU flows into the electrodes of the transmitter, causing electrical burn where the electrodes are attached. For details, refer to the ESU manual NOTE • This transmitter is not protected against noise generated from an electrosurgery unit. • If an electric blanket is used and incorrect heart rate is displayed on the monitor, turn off the pacing pulse detection on the monitor. ECG Measurement Procedure 1. Select the type of electrode lead and disposable electrode according to the purpose. 2. Connect the electrode lead to the ECG/RESP socket. 3. Connect disposable electrodes to the electrode lead and attach electrodes to the patient. After steps 1 to 3 are finished, ECG monitoring automatically starts. 20 Operator's Manual ZM-920PA/930PA Selecting Electrode Lead and Disposable Electrode CAUTION Only Use Nihon Kohden specified electrodes and electrode leads. When other type of electrodes or electrode leads are used, the CHECK ELECTRODE message may be displayed and monitoring may stop. Option Electrode lead BR-916PA BR-906PA 6 electrodes, snap type BR-913PA 6 electrodes, clip type BR-903PA 3 electrodes, snap type 3 electrodes, clip type Operator's Manual ZM-920PA/930PA 21 Connecting the Electrode Lead to the Transmitter Connect the electrode lead to the ECG/RESP socket on the transmitter. CAUTION • Do not shake or swing the transmitter holding the leads or cables connected to the transmitter. The transmitter may come off and injure someone or damage surrounding instruments. • Hold the connector of the electrode lead when connecting/ disconnecting the electrode lead. If you disconnect the electrode lead by pulling the lead, it damages the electrode lead. Selecting the Electrode Position Follow the physician’s instructions for electrode placement when available. For ECG monitoring, electrodes are attached only on the chest to allow patient movement and obtain continuous stable ECG. Following leads are examples. When also monitoring respiration, refer to the “Electrode Position for Respiration Monitoring” section. NOTE The optimum electrode positions for ECG measurement of a patient are not always optimum for respiration measurement of the patient. Select positions suitable for both ECG and respiration measurements, or positions which have priority for one measurement. 22 Operator's Manual ZM-920PA/930PA Six Electrodes Electrode Position The 6-electrode method with lead II and lead V5 is effective for monitoring myocardial ischemia. You can improve monitoring accuracy considerably by adding lead V4 to this combination. Va and Vb can be at any position of the standard 12 leads V1 to V6, but V4 and V5 are most appropriate for myocardial ischemic monitoring. LA RA Va N (RL) Symbol Vb LL Lead Color (Clip Color) Electrode Position RA White (White) Right infraclavicular fossa LA Black (Black) Left infraclavicular fossa LL Red (Red) N (RL) Green (Green) Va Brown (Brown) (BR-906PA) Brown-blue (BR-916PA) Vb Brown (Brown) (BR-906PA) Brown-orange (BR-916PA) Operator's Manual ZM-920PA/930PA Lowest rib on the left anterior axillary line Right anterior axillary line at the same level as LL Fifth intercostal space on the left midclavicular line. (V4 position of standard 12 leads) Left anterior axillary line at the same level as Va. (V5 position of standard 12 leads) 23 Lead Position Standard limb leads Lead I RA Lead II LA Lead III RA LL N (RL) Monopolar limb leads aVR lead N (RL) aVL lead aVF lead RA LA RA LA N (RL) LA LL LL LL N (RL) LA LL LL N (RL) RA RA LA N (RL) Monopolar chest leads V1 to V6 leads to RA LA LL N (RL) When Using 4 to 6 DIN Type Leads to Monitor 6 Lead ECG When the BR-906PA/916PA electrode ON leads are not used, the transmitter is fixed to 3 lead ECG monitoring. To monitor 6 lead ECG using 4 to 6 DIN type leads, the transmitter must be fixed to 6 lead monitoring. To fix transmitter to the 6 lead ECG monitoring, turn off the transmitter CALL key power, press and hold the CALL key and turn on the transmitter power. 9002 RA LA LL Va Vb USAch 608.025 MHz When the transmitter power is turned off and on again, the monitoring mode returns to the original mode. 24 Operator's Manual ZM-920PA/930PA Three Electrodes By using the optional BR-913PA/903PA electrode lead, 3 lead ECG monitoring is available. Electrode Position • Lead MII, which is similar to standard lead II, used when ECG measurement has priority Electrode Position Symbol Lead Color Left infraclavicular fossa LA (N) Black Right infraclavicular fossa White RA (−) Below lowest rib on the LL (+) Red left anterior axillary line • Lead MI, which is similar to standard lead I Change LL and LA of the lead MII. • Lead MIII, which is similar to standard lead III Change RA and LA of the lead MII. If the electrode position shown above is not available due to chest surgery, attach the electrodes to the root of the limbs or below the clavicles for stable ECG monitoring. Operator's Manual ZM-920PA/930PA 25 Connecting the Electrode Lead and Disposable Electrodes Preparing the Patient Skin Shave off excessive body hair. To reduce skin impedance, clean the electrode site with cream or with a cotton pad moistened with the electrode site with cream or with a cotton pad moistened with alcohol. Thoroughly dry the skin with a clean cotton pad. NOTE • For a patient with frequent body movement, rub the sites with Skinpure skin preparation gel. However, do not use Skinpure skin preparation gel for sensitive skin. • Do not place electrodes on a wound or on an inflamed, wrinkled or uneven skin surface. Attaching Electrodes to the Patient CAUTION Do not reuse disposable items. NOTE • To maintain good contact between the electrode and skin, check that the paste of the disposable electrode is not dry. • When contact between the disposable electrode and skin becomes poor, replace electrodes with new ones immediately. Otherwise, contact impedance between the skin and the electrode increases and the correct ECG cannot be obtained. Refer to the electrode operator’s manual for details. 1. 26 Connect the electrode lead to the electrode. Operator's Manual ZM-920PA/930PA 2. Carefully remove the backing paper from the electrode. Avoid touching the adhesive surface. 3. Place the electrode on the previously cleaned skin. Pay attention to the electrode lead color and symbol. 4. Fasten the electrode lead wire with surgical tape with an extra length of wire between the tape and the electrode. This lessens the movement of electrode leads by body movement and helps stable monitoring. Detection and Display of Measurement Condition Electrode Detachment The “ ” LED lights on the transmitter or the “CHECK ELECTRODE” message is displayed on the screen of the monitor in the following cases. • Electrode is detached from skin. • Electrode lead is disconnected from the electrode. • Polarization voltage between the electrode and skin is excessively high. In these cases, check the cause and if necessary, replace electrodes with new ones. CAUTION When the “ELECTRODE OFF” or “CHECK ELECTRODE” message is displayed on the receiving monitor, ECG is not monitored properly and the ECG alarm dose not function. Check the electrode and electrode leads, and if necessary, replace with new ones. Operator's Manual ZM-920PA/930PA 27 Respiration Monitoring Respiration is monitored by measuring changes in impedance between the RA and LL ECG electrodes. This transmitter sends the changes in impedance to the monitor as a respiration waveform. The monitor displays the respiration waveform and calculates respiration rate. Refer to the operator’s manual of the monitor for details. WARNING Interaction Between Minute Ventilation Rate-Adaptive Pacemakers and Cardiac Monitoring and Diagnostic Equipment* The bioelectric impedance measurement sensor of a minute ventilation rate-adaptive implantable pacemaker may be affected by the transmitter which is connected to the same patient. If this occurs, the pacemaker may pace at its maximum rate and the transmitter may give incorrect data to the monitor. If this occurs, disconnect the electrode leads from the patient or change the setting on the pacemaker by referring to the pacemaker’s manual. For more details, contact your pacemaker distributor or Nihon Kohden representative. * Minute ventilation is sensed in rate-adaptive pacemakers by a technology known as bioelectric impedance measurement (BIM). Many medical devices in addition to pacemakers use this technology. When one of these devices is used on a patient with an active, minute ventilation rate-adaptive pacemaker, the pacemaker may erroneously interpret the mixture of BIM signals created in the patient, resulting in an elevated pacing rate. For more information, see the FDA web site. http://www.fda.gov/cdrh/safety.html 28 Operator's Manual ZM-920PA/930PA Respiration Measurement Procedure 1. Select the electrode lead and disposable electrodes. 2. Connect the electrode lead to the ECG/RESP socket. 3. Connect disposable electrodes to the electrode lead and attach electrodes to the patient. After steps 1 to 3 are finished, respiration monitoring automatically starts. Electrode Position for Respiration Monitoring Place the RA and LL electrodes so that the lungs are between the electrodes. NOTE The optimum electrode positions for ECG measurement of a patient are not always optimum for respiration measurement of the patient. Select positions suitable for both ECG and respiration measurements, or positions which have priority for one measurement. Electrode Position Examples NOTE The following examples are when monitoring with 3 electrodes. ECG cannot be monitored correctly when electrodes are attached as the following examples when monitoring with 6 electrodes. Position 1 In this position, respiration measurement is available; however, there is a difference in amplitude between different patients. RA LL Right infraclavicular fossa Fifth intercostal space on the left midclavicular line, V4 Operator's Manual ZM-920PA/930PA 29 Position 2 In this position, the waveform amplitude is usually large and the ECG lead is similar to Lead MII. This position can be generally recommended. RA LL Right infraclavicular fossa Fifth intercostal space on the left midaxillary line, V6 Position 3 In this position, the respiration waveform is optimum, but the ECG lead is unusual. RA LL Right midaxillary at the horizontal level of V4 Fifth intercostal space on the left midaxillary line, V6 Position 4 In this position, the respiration measurement is influenced by the impedance variation of the abdomen, so the cardiac pulse wave included in the respiration wave is reduced. Note that the waveform is inverted in phase compared with the chest movement (the waveform goes down during inspiration). It is difficult to measure the ECG at the same time. RA LL Lowest rib on the right anterior axillary line 30 Lowest rib on the left anterior axillary line Operator's Manual ZM-920PA/930PA SpO2 Monitoring The SpO2 monitoring is only available on the ZM-930PA transmitter. This transmitter sends SpO2 and pulse waveform to the monitor and displays SpO2 data and pulse level bar graph on the LCD. Refer to the operator’s manual of the monitor for details. WARNING • SpO2 measurement may be incorrect in the following cases. • When the patient’s carboxyhemoglobin or methemoglobin increases abnormally. • When dye is injected in the blood. • When using an electrosurgical unit. • During CPR. • When measuring at a site with venous pulse. • When there is body movement. • When the pulse wave is small (insufficient peripheral circulation). • Check the circulation condition by observing the skin color of the measuring site and pulse waveform. Change the measuring site every 8 hours for disposable probes and every 4 hours for reusable probes. The skin temperature may increase at the attached site by 2 or 3°C (4 or 5°F) and cause a burn or pressure necrosis. When using the probe on the following patients, take extreme care and change the measurement site more frequently according to symptoms and degree. • A patient with a fever • A patient with peripheral circulation insufficiency • Neonate or low birth weight infant with delicate skin • When not monitoring SpO2, disconnect the SpO2 cable from the transmitter. Otherwise, noise from the probe sensor may interfere and incorrect data is displayed on the screen. Operator's Manual ZM-920PA/930PA 31 CAUTION • Turn off the power of mobile phones, small wireless devices and other devices which produce strong electromagnetic interference around a patient (except for devices allowed by the hospital administrator). Radio waves from devices such as mobile phones or small wireless devices may be mistaken as respiration or pulse waves and the displayed data may be incorrect. • Normal external light does not affect monitoring but strong light such as a surgical light or sunlight may affect monitoring. If affected, cover the measuring site with a blanket. • Do not pull or bend the probe cable, and do not put caster feet on the probe cable. Do not immerse the probe cable in chemical solutions or water. Failure to follow these instructions may cause cable discontinuity, short circuit, skin burn on the patient and incorrect measurement data. Replace any broken probe with a new one. • When the probe is attached on an appropriate site with sufficient circulation and the error message confirming the probe attachment repeatedly appears, the probe may be deteriorated. Replace it with a new one. • While a patient is on medication which causes vasodilation, the pulse waveform may change and in rare cases the SpO2 value may not be displayed. NOTE When monitoring SpO2, monitor ECG at the same time. The ECG electrode lead works as an antenna for transmitting data from the transmitter to the receiving monitor. If ECG is not measured, the telemetry signal may not be received. 32 Operator's Manual ZM-920PA/930PA Measurement Procedure 1. Select the SpO2 probe. 2. Connect the SpO2 probe to the SpO2 socket. 3. Attach the SpO2 probe to the patient. After steps 1 to 3 are finished, SpO2 monitoring automatically starts. Selecting SpO2 Probe Select an appropriate probe for the patient. CAUTION • Only use Nihon Kohden specified electrodes, electrode lead, SpO2 probe. Otherwise, the maximum performance from the instrument cannot be guaranteed. • Do not use damaged or disassembled probe. It causes incorrect measurement and may injure tha patient. Operator's Manual ZM-920PA/930PA 33 Reusable Probes Model Finger Probe TL-201T Subject (Weight) Attachment Site Adults, children Finger (Weight more than 20 kg) Multi-site probe TL-220T Adult or Infant Finger or toe 3 kg or more Attachment tape Neonate Instep and sole 3 kg or less 34 Operator's Manual ZM-920PA/930PA Disposable Probes CAUTION The disposable probe is not sterilized. Use the disposable probe only for a single patient. Never reuse the disposable probe for another patient because it causes cross infection. Model TL-251T Subject (Weight) Attachment Site Adults Finger or toe (Weight more than 30 kg) TL-252T Children Finger or toe (Weight from 3 to 40 kg) TL-253T Neonates Instep and sole (Weight less than 3 kg) TL-260T Adults, children Finger or toe (Weight more than 3 kg) Neonates Instep and sole (Weight less than 3 kg) Operator's Manual ZM-920PA/930PA 35 Model TL-051S/052S Subject (Weight) Attachment Site Adults Finger (Weight more than 50 kg) Neonates Cable length TL-051S: 80 cm TL-052S: 160 cm TL-061S/062S Instep and sole (Weight less than 3 kg) Adults, children Finger (Weight from 15 to 50 kg) Children, infants Cable length TL-061S: 80 cm TL-062S: 160 cm 36 Toe (Weight from 3 to 15 kg) Operator's Manual ZM-920PA/930PA Model TL-271T/271T3 Cable length TL-271T: 0.8 m TL-271T3: 1.6 m TL-272T/272T3 Cable length TL-272T: 0.8 m TL-272T3: 1.6 m TL-273T/273T3 Subject (Weight) Adult 30 kg or more Child 10 to 50 kg Neonate 3 kg or less Attachment Site Finger or toe Instep Adult 40 kg or more Cable length TL-273T: 0.8 m TL-273T3: 1.6 m TL-274T/274T3 Infant 3 to 20 kg Finger or toe Cable length TL-274T: 0.8 m TL-274T3: 1.6 m Operator's Manual ZM-920PA/930PA 37 Connecting SpO2 Probe to the Transmitter Connect the probe to the SpO2 socket on the transmitter. CAUTION • Do not shake or swing the transmitter while holding the cables connected to the transmitter. The transmitter may come off and injure someone or damage surrounding instruments. • Hold the connector when connecting/disconnecting the probe. If you disconnect the SpO2 probe pulling the cable, it damages the cable. Attaching the Probe to the Patient For details, refer to the operator’s manual of each probe. WARNING • When using the TL-201T finger probe, do not fasten the probe and cable to the finger by wrapping with tape. This may cause burn, congestion or pressure necrosis from poor blood circulation. • When using probes other than the TL-201T finger probe, to avoid poor circulation, do not wrap the tape too tight. Check the blood circulation condition by observing the skin color and congestion at the skin peripheral to the probe attachment site. Even for shortterm monitoring, there may be burn or pressure necrosis from poor blood circulation, especially on neonates or low birth weight infants whose skin is delicate. Accurate measurement cannot be performed on a site with poor peripheral circulation. 38 Operator's Manual ZM-920PA/930PA • Check the circulation condition by observing the skin color of the measuring site and pulse waveform. Change the measuring site every 8 hours for disposable probes and every 4 hours for reusable probes. The skin temperature may increase at the attached site by 2 or 3°C (4 or 5°F) and cause a burn or pressure necrosis. When using the probe on the following patients, take extreme care and change the measurement site more frequently according to symptoms and degree. • A patient with a fever • A patient with peripheral circulation insufficiency • Neonate or low birth weight infant with delicate skin CAUTION • NIBP and SpO2 can be measured on the same limb, but the SpO2 monitoring may not be accurate during NIBP measurement. Be careful when reading the SpO2 values. • If the attachment site is dirty with blood or bodily fluids, clean the attachment site before attaching the probe. If there is nail polish on the attachment site, remove the polish. Otherwise, the amount of transmitted light decreases, and measured value may be incorrect or measurement cannot be performed. • If the skin gets irritated or redness appears on the skin from the probe, change the attachment site or stop using the probe. Take extreme care for the patients with delicate skin. • When the probe is attached on an appropriate site with sufficient circulation and the error message confirming the probe attachment repeatedly appears, the probe may be deteriorated. Replace it with a new one. • Do not use a probe that is deteriorated by aging. Accurate measurement cannot be performed. • Neonatal skin is delicate. Remove the probe and tape carefully and slowly. • When removing a probe that is taped to the skin, do not pull the probe cable because this can damage the cable. • When removing the probe from the attachment tape, do not pull the Operator's Manual ZM-920PA/930PA 39 sensor cable because this can damage the cable. • Do not immerse the disposable probe in detergents or water. If the probe adhesive surface gets wet, adhesiveness becomes weak and the probe cannot be attached to the skin. • Before using the TL-260T multi-site Y probe, be sure to attach the probe to the sponge attachment tape S or L. Do not use the probe without the sponge attachment tape attached. Using the probe without the sponge attachment tape causes incorrect measurement and may injure the skin at the attachment site. • When fixing the TL-260T multi-site Y probe with the sponge attachment tape, confirm that the adhesive part of the tape is not on the skin. The adhesive may cause oversensitive symptoms on the skin such as redness or itch. If the adhesive touches the skin, remove it carefully and slowly because neonatal skin is very delicate. • Do not use a dirty sponge attachment tape. The measurement value may be incorrect. • Use the sponge attachment tape S and L only with the specified products. • Refer to the probe instruction manual for details. Starting Measurement When monitoring starts, SpO2 and pulse waveform are sent to the monitors and SpO2 data and pulse level bar graph are displayed on the transmitter LCD. You can turn off the display of SpO2 data and pulse level bar graph on the LCD. Refer to the “Turning SpO2 Data and Pulse Level Bar Graph Display On/Off” section. CAUTION When the probe is attached on an appropriate site with sufficient circulation and the error message confirming the probe attachment repeatedly appears, the probe may be deteriorated. Replace it with a new one. 40 Operator's Manual ZM-920PA/930PA Turning SpO2 Data and Pulse Level Bar Graph Display On/Off You can turn off the display of SpO2 data and pulse level bar graph on the LCD. SpO2 display off Press the CALL key for more than 3 seconds within 10 seconds after turning transmitter power on (after a “peep” sound). CALL key RA LA LL Va Vb “%SpO2” is not displayed. When SpO2 monitoring starts, SpO2 data and pulse level bar graph are not displayed on the LCD. USAch 9002 608.025 MHz To turn SpO2 display on, turn the transmitter power off and turn the power on again. Detecting and Displaying Measurement Condition External Light Noise Alarm CAUTION When measuring under strong light (surgical light, bilirubin light, sunlight, etc.), cover the probe with a blanket or cloth. Otherwise, noise may interfere. Strong external light (surgical light or inverter type fluorescent lamp, etc.), may affect SpO2 monitoring. When external light is too strong to correctly measure SpO2, the transmitter generates an alarm tone (“pip” sound every 0.5 seconds). Cover the probe attachment site with blanket or cloth. Operator's Manual ZM-920PA/930PA 41 Insufficient Light Alarm When sufficient light cannot be obtained from the photo emitter of the probe, the transmitter generates the following sound and indication. (4) (1) “peep” sound (every 1 second) (2) (2) pulse level bar graph is maximum (all bars are lit.) (3) SpO2 data is displayed as “ ” (4) %SpO2 is blinking. (3) In this case, change the attachment site to the appropriate site. Refer to the operator’s manual of the SpO2 probe. Probe Malfunction Alarm CAUTION When any of the following occurs, the probe may be broken. Replace it with a new one and check the probe. • The transmitter generates “pip” sound every 0.25 seconds. • SpO2 data is 85% and blinking. When Measurement Condition is Unstable SpO2 data blinks every 1 second when SpO2 signal stability decreases and the transmitter cannot detect correct pulse waveform because of patient body movement, poor attachment condition or poor circulation condition at the probe attachment site. CAUTION SpO2 data blinking every second indicates an unstable pulse waveform and displayed SpO2 value may be inaccurate. The displayed data may not reflect sudden SpO2 changes. 42 Operator's Manual ZM-920PA/930PA Alarm List (5) %SpO2 indication (1) Displayed as LED on ZM-920PA (4) pulse level bar graph (2) Sound Single “peep” sound for 4 s --- (1) Continuous “peep” sound All lights are off --- Intermittent “pip” sound every 0.5 s Display --- (2) RA LA LL Va Vb (3) SpO2 data Cause Countermeasure The CALL key is pressed. The sound lasts while the key is pressed. The battery voltage decreases and battery charge is almost zero. Battery is completely discharged. Electrode lead is disconnected from the electrode. Electrode lead is disconnected from the transmitter. Electrode lead discontinuity --- Electrode is not firmly attached to the skin. Polarization voltage is abnormally high. SpO2 measurement site is under fluorescent light, surgical light, sunlight, etc. Operator's Manual ZM-920PA/930PA Replace the batteries with new ones. Replace the batteries with new ones. To stop the sound, turn off the power. Firmly connect the electrode lead to the electrode. Firmly connect the electrode lead to the transmitter. Replace the electrode lead with a new one. Replace the electrode with a new one. Cover the measurement site with a blanket or cloth. 43 Sound Intermittent “peep” sound every 1 s Display (3) (4) all lit (5) blinking Cause Cannot receive sufficient light from the probe photo emitter. Intermittent “pip” sound every 0.25 s --- (3) 85%, blinking Broken probe (3) blinking Patient body movement Probe is not attached securely. 44 Countermeasure Attach probe to a site with 6 to 14 mm thickness where sufficient light can be received. Replace the probe with a new one. Remove the cause by checking the patient condition and changing the attachment site. Securely attach the probe. Operator's Manual ZM-920PA/930PA Troubleshooting If the problem still remains after checking the following, contact your Nihon Kohden distributor. Problem The power cannot be turned on. Nothing is displayed on the LCD after turning the power on. (ZM-930PA only) Nothing is displayed on the monitor after turning the transmitter power on. Signal receiving condition is poor. Cause Batteries are not installed correctly. The battery polarity is wrong. Batteries are completely discharged. SpO2 display is turned off. The channel of the transmitter and monitor does not match. Electrode lead is not connected to the transmitter. Another transmitter of the same channel is used near by. Signals are mixing. The transmitter is damaged. Operator's Manual ZM-920PA/930PA Countermeasure Install the batteries correctly. Replace the batteries with new ones. Turn off the power, and turn on the power again. Set the correct channel on the monitor. Connect the electrode lead to the transmitter. ECG electrode lead works as an antenna for transmitting data to the receiving monitor. If ECG is not measured, the signal may not be received. Turn the transmitter power off. If the monitor still receives a signal, there is a high probability that another transmitter of the same channel is used nearby. Follow the instruction of your channel administrator and use another transmitter of a different channel. Follow the instruction of your channel administrator and use another transmitter of a different channel. Contact your Nihon Kohden distributor. 45 Problem 3 electrode leads are properly attached to the patient but LEDs light. Heart rate of the patient who is using an electric blanket cannot be monitored on the receiving monitor. ECG baseline is thick. (Hum is overlapping) Respiration waveform measurement is unstable. SpO2 data is unstable and not reliable. Cause The transmitter is fixed to 6 lead monitoring. Countermeasure Turn off and on the transmitter power. Pacing pulse detection is set to ON on the monitor. Turn off the pacing pulse detection. The gel on the electrode is dried out. The gel on the electrode is coming off. Electric blanket is used. Replace the electrode with a new one. Hum filter is set to OFF on the monitor The gel on the electrode is dried out. The gel on the electrode is coming off. The probe size is not appropriate for the patient. Probe is attached to the same limb that is used for NIBP measurement. Probe attachment condition is poor. Probe is about to detach from the skin. External light gets in. Measurement site is dirty. Patient is wearing nail polish. 46 Cover the blanket with a shield cover. Set the filter to ON. Replace the electrode with a new one. Use the appropriate probe for the patient. Attach the probe to the opposite limb. Avoid a site where blood circulation condition changes greatly. Firmly attach the probe according to the procedure in the probe operator’s manual. Remove dirt and nail polish. Operator's Manual ZM-920PA/930PA Changing the Transmitter Channel The transmitter channel can be changed by the QI-901PK Channel Writer. To change the channel number, refer to the channel writer manual. WARNING The following actions must be taken to properly receive the transmitter signal of the correct patient on the receiving instrument. Otherwise, there may be signal loss or signals may mix causing a serious accident, such as monitoring a different patient. • Assign a channel administrator in the hospital and only he or she should manage channel assignments. • The channel administrator must manage the channels in the facility so that there is no signal interference. • When the transmitter channel is changed, the channel administrator must check that the channel on the receiving monitor is also changed and the signal is properly received. • The channel administrator must replace the channel number label on the transmitter with the new one after changing the channel. Operator's Manual ZM-920PA/930PA 47 Lifetime and Disposal Disposing of Used Batteries Replacement When the “ ” LED is lit or the “ ” is displayed on the LCD during operation, the batteries are running out. Replace the batteries with new ones. When using rechargeable batteries, recharge them. Disposal Before disposing of the batteries, check with your local solid waste officials for details in your area for proper disposal. It may be illegal to dispose of these batteries in the municipal waste stream. Disposing of Electrodes and SpO2 Probes Refer to the manual of each item. 48 Operator's Manual ZM-920PA/930PA Cleaning, Disinfection and Sterilization Transmitter and Electrode Lead WARNING If detergents or dirty liquid spills into the transmitter, clean it and dry it completely before use. If the wet transmitter is used, the patient or anyone in contact with the transmitter may receive an electric shock. CAUTION • Before cleaning or disinfecting the transmitter, remove the batteries from the transmitter. • The transmitter cannot be sterilized. Cleaning Wipe the transmitter and electrode leads with a soft cloth moistened with disinfecting alcohol or neutral detergent diluted with water. After cleaning, dry them completely. Disinfection CAUTION • Do not immerse the electrode lead connector in liquid. • Do not disinfect with hypochlorous acid. • Use the recommended concentration. Wipe the outside surface of the transmitter and electrode lead with a non-abrasive cloth moistened with any of the disinfectants listed on the next page. Use the recommended concentration. Operator's Manual ZM-920PA/930PA 49 Disinfectant Glutaraldehyde solution Alkyldiaminoethylglycine hydrochloride Benzalkonium chloride Benzethonium chloride solution Chlorohexidine gluconate solution Concentration (%) 2.0 0.5 0.2 0.2 0.5 SpO2 Probe Refer to the probe manual. 50 Operator's Manual ZM-920PA/930PA Replacing the Battery Case Cover When the battery case cover is damaged, replace it with a new one. Battery case cover, code no. 6113-046365C. Other than the battery case cover, there are no serviceable parts for the transmitter. Repair Parts Availability Policy Nihon Kohden Corporation (NKC) shall stock repair parts (parts necessary to maintain the performance of the instrument) for a period of 6 years after NKC announces discontinuation of the instrument. In that period, NKC or its distributors will repair the instrument. This period may be shorter than 6 years if the necessary board or part is not available. For discontinuation announcements, contact your Nihon Kohden distributor or representative. Operator's Manual ZM-920PA/930PA 51 Specifications ECG measurement Channels: Input range: DC offset: Input impedance: Pacing pulse detection: Respiration measurement Measuring method: Impedance range: SpO2 measurement Measuring range: Measuring accuracy When the measuring accuracy of the SpO2 probe is not considered: ±5 mV or more ±500 mV or more 5 MΩ or more (5 Hz) ANSI/AAMI EC13 Based upon Pacemaker pulse rejection Capability Impedance method 0 to 2 kΩ 0 to 100%, in 1% steps ±1 digit (80% ≤ SpO2 ≤ 100%) ±2 digit (50% ≤ SpO2 ≤ 80%) Less than 50% is not specified. When the measuring accuracy of the SpO2 probe is considered: ±2 digit (80% ≤ SpO2 ≤ 100%) ±3 digit (70% ≤ SpO2 ≤ 80%) Less than 70% is not specified. Transmitter FCC regulation: Field strength limits: Undesired emission: 52 FCC part 95 Subpart-H Wireless Medical Telemetry Service (WMTS) <200 mV/m (at 3 m) below 960 MHz: 200 μV/m (at 3 m) above 960 MHz: 500 μV/m (at 3 m) Operator's Manual ZM-920PA/930PA Antenna: Transmission channel: Transmission frequency range: Channel spacing: Modulation scheme: Occupied bandwidth: Effective radiated power: Safety standards Safety standard: According to the type of protection against electrical shock: ECG electrode lead indicated on the transmitter 608.0250 to 613.9750 MHz 50 kHz or 37.5 kHz (12.5 kHz when interleaved) FSK (Frequency Shift Keying) <20 kHz 1.0 mW (conducted) CSA C22.2 No. 601-1 M90: 1994 IEC 60601-1: 1988 IEC 60601-1 Amendment 1: 1991 IEC 60601-1 Amendment 2: 1995 IEC 60601-1-2: 1993 IEC 60601-2-27: 1994 INTERNALLY POWERED EQUIPMENT According to the degree of protection against electrical shock: ECG/impedance method respiration: DEFIBRILLATION-PROOF TYPE CF APPLIED PART SpO2: DEFIBRILLATION-PROOF TYPE BF APPLIED PART According to the degree of protection against harmful ingress of water: IPX0 (Ordinary equipment) According to the degree of safety of application in the presence of a FLAMMABLE ANAESTHETIC MIXTURE WITH AIR, OR WITH OXYGEN OR NITROUS OXIDE: Equipment not suitable for use in the presence of FLAMMABLE ANAESTHETIC MIXTURE WITH AIR, OR WITH OXYGEN OR NITROUS OXIDE According to the mode of operation: CONTINUOUS OPERATION Operator's Manual ZM-920PA/930PA 53 Water resistance Water does not get inside the transmitter except for the battery case when immersed in water up to 30 cm deep for 3 minutes. Power requirements Battery type: Battery lifetime: ZM-930PA: ZM-920PA: two AA type alkaline dry cell batteries, manganese dry cell batteries, NiCd rechargeable batteries, NiMH batteries approximately 3 days (with alkaline batteries, measuring ECG, respiration and SpO2 of approximately 60 kg weight adult male patient at the pointing finger) approximately 4 days (with alkaline batteries, measuring ECG and respiration only) approximately 4 days Environment Operating environment Operating temperature: Operating humidity: Operating atmospheric pressure: Operating voltage: 5 to 40°C, 41 to 104°F 30 to 85% (non-condensing) 70 to 106 kPa 1.6 to 3.2 V Storage environment Storage temperature: Storage humidity: Storage atmospheric pressure: Dimension and Weight Dimension: Weight (without batteries): 54 −20 to 65°C, −4 to 149°F 15 to 95% (non-condensing) 70 to 106 kPa 78 W × 122 H × 26 D (mm) ZM-930PA: about 180 g ZM-920PA: about 165 g Operator's Manual ZM-920PA/930PA Standard Accessories Name Strap Operator's Manual ZM-920PA/930PA Q’ty Supply code Y233 55 Options CAUTION Use only Nihon Kohden electrodes, electrode leads and SpO2 probes to assure maximum performance from your instrument. ECG/RESP 56 Name Application Electrode lead 3 electrodes, clip type, lead length 80 cm 3 electrodes, snap type, lead length 80 cm 6 electrodes, clip type, lead length 80 cm 6 electrodes, snap type, lead length 80 cm Model Q’ty Supply code BR-903PA K911A BR-913PA K910B BR-906PA K912A BR-916PA K915A Operator's Manual ZM-920PA/930PA SpO2 Name Finger probe (reusable) Multi-site probe (reusable) SpO2 probe (for adult, disposable) SpO2 probe (for child, disposable) SpO2 probe (for neonate, disposable) Multi-site Y probe (for low birth weight infant/child/ neonate, disposable) SpO2 probe (for adult, disposable) SpO2 probe (for child, disposable) SpO2 probe (for neonate/adult, disposable) SpO2 probe (for child/infant, disposable) SpO2 probe (for adult/neonate, disposable) SpO2 probe (for child/infant, disposable) COTTONY tape Foam tape for TL-051S/052S/ 061S/062S Attachment tape for TL-220T/ 251T/252T/253T Attachment tape S for TL-260T Attachment tape L for TL-260T Cable length Model/ Code No. 0.6 m 1.6 m TL-201T Q’ty Supply Code No. P225H P225F TL-220T P225G TL-251T P201A TL-252T P201B 1.6 m TL-253T 0.8 m 1.6 m 0.8 m 1.6 m 0.8 m 1.6 m 0.8 m 1.6 m 0.8 m 1.6 m 0.8 m 1.6 m Operator's Manual ZM-920PA/930PA P201C TL-260T P205A TL-271T TL-271T3 TL-272T TL-272T3 TL-273T TL-273T3 TL-274T TL-274T3 TL-051S TL-052S TL-061S TL-062S 340703 P203A P203E P203B P203F P203C P203G P203D P203H P228A P228B P229A P229B P259 24 20 4 × 25 packages P260 3 × 30 packages P263 P260A 24 P260B 57
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Create Date : 2007:08:10 11:09:35+09:00 Creator Tool : PageMaker 7.0J Modify Date : 2007:08:10 11:11:54+09:00 Metadata Date : 2007:08:10 11:11:54+09:00 Format : application/pdf Title : Cover2 ZM920PA-930PA OM-A.pmd Creator : tk3225 Document ID : uuid:d3d4d873-2b0e-44b5-adae-88423206d254 Instance ID : uuid:a4bbb24b-9154-40d8-937c-b564924cd934 Has XFA : No Page Count : 70 Author : tk3225EXIF Metadata provided by EXIF.tools