Nikon If Not Then MA100
User Manual: Nikon If not then Manual: ://www.nikoninstruments.com/images/stories/PDFs/MA100
Open the PDF directly: View PDF
.
Page Count: 4
| Download | |
| Open PDF In Browser | View PDF |
Specifications Optics Observation image Observation method Focusing section Nosepiece Stage Illuminator Eyepiece tube Max. power consumption External dimensions Weight CFI60 optics Upright back image Brightfield and simple polarizing (when using MA-P/A Simple Polarizing Set) Vertical action revolver (fixed stage) Single-axis coarse/fine adjustment handle with 8.5mm stroke (coarse adjustment of 37.7mm per turn, fine adjustment of 0.2mm per turn) Brightfield 5-position nosepiece MA-SP Plain Stage: 170 x 230mm (includes two holders for acrylic samples φ30mm aperture, crescent aperture) Can be combined with MA-SRSH1 Universal Specimen Holder or MA-SH3 Specimen Holder 3. TI-SM Mechanical Stage CH: 126 x 80mm stroke; Handle can be attached on the right or left side of the stage Can be combined with MA-SH1 Specimen Holder 1, MA-SH2 Specimen Holder 2, or C-HU Universal Holder. MA-SR Rectangular Stage: 50 x 50mm stroke (includes two sample holders at φ20mm and 40mm apertures) and handle fixed on right side. Can be combined with MA-SRSH1 Universal Specimen Holder or MA-SH3 Specimen Holder 3. Internal power supply 6V 30W Halogen Lamp (long-life type) Condenser built-in (lever operated) φ25mm filter (includes NCB11 and ND4) can be inserted. Built-in mirror type, 45° depression angle and 50 to 75mm interpupillary adjustment 96VA 228 x 663 x 382 mm (W x D x H) Approx. 9kg Dimensions (mm) 118 210 188 167 205 123 318 673 400 228 226 174 230 90 210 118 124 170 118 228 50 45 110 231 Specifications and equipment are subject to change without any notice or obligation on the part of the manufacturer. October 2006 ©2006 NIKON CORPORATION The products detailed in the brochure are controlled by the Japanese Foreign Exchange and Foreign Trade Law and the International Export Control Regime. If there is a possibility that they may be utilized for the development of weapons of mass destruction, etc., they shall not be exported without authorization from the government. NIKON CORPORATION Parale Mitsui Bldg., 8, Higashida-cho, Kawasaki-ku, Kawasaki, Kanagawa 210-0005, Japan phone: +81-44-223-2175 fax: +81-44-223-2182 ISO 9001 http://www.nikon-instruments.jp/eng/ NIKON INSTRUMENTS INC. 1300 Walt Whitman Road, Melville, N.Y. 11747-3064, U.S.A. phone: +1-631-547-8500; +1-800-52-NIKON (within the U.S.A.only) fax: +1-631-547-0306 http://www.nikonusa.com/ NIKON INSTRUMENTS EUROPE B.V. P.O. Box 222, 1170 AE Badhoevedorp, The Netherlands phone: +31-20-44-96-222 fax: +31-20-44-96-298 http://www.nikon-instruments.com/ NIKON INSTRUMENTS (SHANGHAI) CO., LTD. CHINA phone: +86-21-5836-0050 fax: +86-21-5836-0030 (Beijing office) phone: +86-10-5869-2255 fax: +86-10-5869-2277 (Guangzhou office) phone: +86-20-3882-0552 fax: +86-20-3882-0580 Printed in Japan (0610-05) Am/M Accredited by the Dutch Council for Accreditation ISO 9001 Certified NIKON CORPORATION Instruments Company NIKON SINGAPORE PTE LTD SINGAPORE phone: +65-6559-3618 fax: +65-6559-3668 NIKON MALAYSIA SDN. BHD. MALAYSIA phone: +60-3-78763887 fax: +60-3-78763387 NIKON INSTRUMENTS KOREA CO., LTD. KOREA phone: +82-2-2186-8410 fax: +82-2-555-4415 NIKON CANADA INC. CANADA phone: +1-905-625-9910 fax: +1-905-625-0103 NIKON FRANCE S.A.S. FRANCE phone: +33-1-45-16-45-16 fax: +33-1-45-16-00-33 NIKON GMBH GERMANY phone: +49-211-9414-0 fax: +49-211-9414-322 NIKON INSTRUMENTS S.p.A. ITALY phone: +39-55-3009601 fax: +39-55-300993 NIKON AG SWITZERLAND phone: +41-43-277-2860 fax: +41-43-277-2861 Code No. 2CE-KVNH-1 ISO 14001 ISO 14001 Certified NIKON CORPORATION Yokohama Plant NIKON UK LTD. UNITED KINGDOM phone: +44-20-8541-4440 fax: +44-20-8541-4584 NIKON GMBH AUSTRIA AUSTRIA phone: +43-1-972-6111-00 fax: +43-1-972-6111-40 NIKON BELUX BELGIUM phone: +32-2-705-56-65 fax: +32-2-726-66-45 Inverted Metallographic Microscope Introducing a d u with a small f rable, user-friendly micr ootprint, supe oscope rior image qu ality, and grea t cost perform ance e g ta S r ro ir e ur rt gm e p ra A ph ia D M 0 I6 F C er iz ar zer l o P aly n A / The ECLIPSE MA100 is a compact-size inverted microscope specially designed for reflected illumination. This instrument was developed for brightfield observation and simple polarizing observation. Thanks to its compact, durable design, simple operation, and high-contrast observation and image capture, it is excellent for metallographic and electronic components as well as use at product sites in the materials field and quality control departments. Aperture Diaphragm Comes standard with a condenser The epi illuminator comes standard with a condenser which enables users to control image contrast and depth of field of the sample. Stage Stable control even with heavy samples A newly developed stage boasting superior durability Nikon developed the all-new MA-SR Rectangular Stage especially for the MA100. The three-plate structure gives the microscope stable control and superior durability and enables observation of heavy samples, including embedded samples , that are still mounted on a grinder s holder. CFI60 Mirror Identify objective magnification at a glance with an adjustable mirror. The ECLIPSE MA100 ships complete with a mirror for checking objective lenses, which makes observation much more efficient. Now users can verify what objective lens is being used as well as the observation position of the sample in a comfortable position, without having to look beneath the stage. Sharp, clear images using CFI60 optics , Nikon s proprietary CFI60 optics provide high NA and a longer working distance. CFI60 optics deliver bright, high-resolution images. Up to five objective lenses can be mounted. Polarizer/Analyzer 2 Simple polarization observation with a single-action polarizer/analyzer mechanism. This device makes possible simple polarizing observation, which is effective for samples such as polymer materials. It takes just a single action to engage the polarizer and analyzer in the light path. The polarizer can rotate 360˚ degrees, allowing users to set a polarization direction suited to the sample being observed. 3 Digital Sight Series A flexible system that enables various configurations consisting of a camera head and a control unit to suit the needs of each sample or application. of newly developed image integration software The NIS-Elements series is used for the control software. This software allows the user to perform everything from basic image capture to the measurement, analysis, and management of captured images. Users can add a wide array of the plug-ins to basic packages according to their intended use. S: Standard O: Optional Main functions of each package F NIS-Elements F Package Free bundle This package enables display of a scale over a live image, switching to fullscreen display, and other functions. It allows the user to easily capture images with a simple intuitive control screen. D NIS-Elements Documentation Standard set This package provides functions for performing measurements and creating reports. Use it for general microimage capture in the industrial field. Expandability is also possible by adding plug-ins, such as EDF and databases. Br NIS-Elements Basic Research Camera Heads Option In addition to the measurement function and report-generating function of NISElements Documentation, this package enables automatic object measurement by creating a binary image. Expandability is also possible by adding plug-ins, such as EDF and databases. High-difinition color camera head Image sensor 5-megapixel 2/3-inch color CCD Max. recordable pixels 2,560 x 1.920 Cooling None Display speed 5.9 to 23 fps Sensitivity Equivalent to ISO 64 The DS-Fi1 features a 5-megapixel CCD that can faithfully capture 2,560 x 1,920-pixel high-resolution images. This camera head features frame rates far beyond conventional models with improved image quality and ease of use, including a refined IR cut filter. Advanced functionality and high cost performance are the hallmarks of the DS-Fi1. Operating environment The following PC environment is recommended for maximizing the performance of NIS-Elements. CPU 3.2GHz Intel Pentium IV processor or better RAM 1GB or more OS Microsoft Windows XP SP2 (English version) Hard disk space 600MB or more required for installation Display 1280 x 1024 or better (TrueColor mode) High-speed color camera head Image sensor 2-megapixel 1/1.8-inch color CCD Max. recordable pixels 1,600 x 1,200 Cooling None Display speed 5.0 to 30 fps Sensitivity Equivalent to ISO 100 Application window F (There is no organizer window.) D Br Freely select the window layout according to the purpose at hand. F Enlarge/reduce, full screen, and magnifying glass Capture thumbnail Scale, annotation, and profile Grid LUT, histogram, and sequence replay 3D surface model Auto-capture Image capture Multi-dimensional support Time lapse Z series and multi-point Large image Live compare BMP, TIFF, JPEG, and JPEG2000 Data formats GIF, PNG, ICS/IDS, and original format White balance and tone Image processing LUT and shading correction Contrast and hue/saturation correction Edge enhancement, averaging, and smoothing EDF and realtime EDF Crop Image editing Image overlay Cut, copy, paste, rotate, invert, and resize Component extraction Pseudo-color Calibration (length) Image analysis Manual measurement (count, length, area, angle, circle, and ellipse) Auto-measurement (digitization and object extraction) 3D measurement (EDF) Time measurement Microscope control Peripheral device control Control of other companies' devices Organizer layout Screen control Layout manager Customize Printing, PDF output, mail transmission Other Optical configuration Report generator Macros Databases Window style Image display S S S (live) S S S S S 3 (RGB) S S SDI D Br S S S S S S S S S S O O S S 4D 3D Multi Individual S S S S O S S S S S S S S S S S S S O S S S 4 (RGB+α) Multi-channel S S S S S S S S S S O S O O O S S O O S S S S O O S S S S S S S S S O SDI(Japanese) MDI fps*1 The DS-2Mv features a 2-megapixel CCD that displays SXGA video at a high frame rate of 15 (max. 30fps). This camera head enables the smooth display of live images and the capture of crystal-clear still images with a high sensitivity. With the exceptionally high frame rates it can even be used for live monitoring. Databases *1) When using DS-L2 and outputting to an external monitor. * In addition to these camera heads, Nikon also has a variety of other models, such as the DS-5Mc high-definition camera head with a built-in cooling mechanism. Full-screen window Plug-in D Br Users can easily create a variety of databases, file types and store images with a simple click of the mouse. Image categorization is easier than ever before. Camera Control Unit PC-Based Control Unit The DS-U2 controls everything from live image display and capture to advanced image processing and analysis on a computer. It supports a wide range of applications. Docked controls window Measurement Organizer window D (Manual only) Br EDF (Extended Depth of Focus) Plug-in D Br Create reports containing images, database descriptions, and measured data. PDF files can be created directly from NIS-Elements. Measure quantity, length, radius, angle, area, and pixel intensity profile. 4 Simple connection via high-speed USB 2.0 The U2 control unit employs a USB 2.0 interface for connecting with a PC. It makes operation with a PC seamless and improves transfer speed up to 1.6 faster than previous models. Report generator D Br Create reports containing images, database descriptions, and measured data. PDF files can be created directly from NIS-Elements. 5 Digital Sight Series (2) System Diagram Stand-alone Control Unit The DS-L2 features a large high-definition LCD and a host of features. There is no need for a PC and monitor, which allows the system to be used with a flick of a switch. Large, high-definition monitor MA-SH1 Specimen Holder 2 The unit has a built-in 8.4-inch TFT LCD monitor with 1,024 x 786 pixels, a brightness of Handy save/print features The unit enables data to be saved on USB memory sticks, as well as on CF cards and microdrives, transferred through a network path. In addition, it comes standard with direct printing to PictBridge printers. It also features “ Real 10 ”modes that make it possible to set and adjust print scaling. 350cd/m2, Frequently used features are displayed as toolbar buttons. This enables control without hampering the display of the image to be captured. It is also possible to customize the buttons. Scene mode: optimal image capture with a single button The unit features three scene modes for industrial samples. These modes all offer capture conditions optimized for the particular sample type. Users can also register up to seven freely configurable custom modes. Scene modes for industrial samples Mode for metal, ceramics, and plastics Mode for circuit boards MA-SH3 Specimen Holder 3 C-Mount Direct CCTV Adapter An extensive array of tool functions Users can measure captured images and enter line contrast and other settings using the overlay. Users can also save data in image files and output measurement data. MA100-EPRGS Grain Size Reticle MA-SR Rectangular Stage MA-SP Plain Stage Scale display/alignment functions C-Mount Adapter A 0.7x MA-SH2 Specimen Holder 2 and alignment function Measurement and alignment is possible by standard-length calibration (up to seven types can be registered). (Includes two holders for acrylic samples) C-W10xA (Includes two specimen holders) C-HU Universal Holder C-W15x Scale Example of toolbar buttons (Left: Short/Right: Large) MA-SRSH1 Universal Specimen Holder and 400:1 contrast. ●Measurement Easy-to-use toolbar Mode for wafers and IC chips Digital Camera System for Microscopy Digital Sight Series TI-SM Mechanical Stage CH XY scale Screen pattern Grid lines XY measurement LU Plan Fluor EPI 5x Measurement functions Distance between Point-to-line two points distance ●Drawing LU Plan Fluor EPI 10x θ Angle circumference/ diameter Area Distance between circle center Pitch functions LU Plan Fluor EPI 20x Users can input and display lines, comments, and other useful elements. • Straight lines (Arrows can be set.) • Curves • Count markers • Text entry • Superimposition 6V30W Halogen Lamp LU Plan Fluor EPI 50x Inverted Metallurgical Microscope LU Plan Fluor EPI 100x ●100V/120V ●230V MA-P/A Simple Polarizing Set (semitransparent image overlay for comparative purposes) Accessory (→P.4∼5) Stages + Holders Objective Lenses Universal-type AC power adapter 3 1 1 MA-SP Plain Stage 2 Acrylic Sample Holder (standard accessory/φ30mm aperture) 3 MA-SH3 Specimen Holder 3 4 MA-SRSH1 2 4 5 Universal Specimen Holder USB (D) CFI60 optics objective lens Type CFI L Plan EPI CFI LU Plan Fluor EPI 5 Acrylic Sample Holder (standard accessory/crescent aperture) 1 CFI LU Plan EPI ELWD CFI L Plan EPI SLWD 2 1 2 3 4 3 * Use in combination with the MA-SP Plain Stage. 4 6 TI-SM Mechanical Stage CH C-HU Universal Holder MA-SH1 Specimen Holder 1 MA-SH2 Specimen Holder 2 3 CFI LU Plan Apo EPI CFI L Plan Apo EPI WI Simple polarizer Power 2.5x 5x 10x 20x 50x 100x 20xA 50xA 100xA 20x 50x 100x 100x 150x 150x PC (Windows XP) Numerical aperture(NA) Working distance (W.D.)(mm) 0.075 8.8 0.15 23.5 0.30 17.5 0.45 4.5 0.80 1.0 0.90 1.0 0.40 13.0 0.55 10.1 0.80 3.5 0.35 24.0 0.45 17.0 0.70 6.5 0.95 0.4 0.95 0.3 1.25 0.25 Dedicated camera cable (3m) (→P.6) Standard set Network server PC Pict bridge printer (WEB、FTP、telnet) (Mass storage class) (Direct printing) DVI-I LAN (Ethernet) USB (D) USB (H) USB (H) Grain Size Reticle USB Memory Stick Compact flash card, microdrive 2 4 Option Projector Large screen monitor (External output) (External output) 1 4 Camera head DS series Camera control unit USB Mouse Dedicated remote controller/ strobe, etc. 1 MA-SR Rectangular Stage 2 Specimen Holder (standard accessory/φ20mm aperture) 3 MA-SH3 Specimen Holder 3 4 MA-SRSH1 5 Specimen Holder (standard accessory/φ40mm aperture) Universal-type AC power adapter Camera control unit Dedicated camera cable (3m) USB Keyboard Camera head DS series 7
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2006:10:25 13:24:01 Producer : Acrobat Distiller 4.0 for Macintosh Modify Date : 2006:10:26 13:49:51+09:00 Page Count : 4EXIF Metadata provided by EXIF.tools