Nikon If Not Then MA100 MA200

User Manual: Nikon If not then Manual: ://www.nikoninstruments.com/images/stories/PDFs/MA100-MA200

Open the PDF directly: View PDF PDF.
Page Count: 6

DownloadNikon  If Not Then MA100-MA200
Open PDF In BrowserView PDF
Inverted Metallographic Microscopes ECLIPSE MA200/MA100

Specifications (MA200)
Main body
Focusing mechanism
Illumination

Light Distribution
Optics
Image orientation
Observation method
Revolving nosepieces
Stage
Trinocular eyepiece
Power input
Electric power consumption
Maximum electric power consumption
Weight Approximately

Focusing nosepiece (Fixed stage) Coaxial coarse/fine adjustment knob (torque adjustable)
Coarse adjustment of 4.0mm per rotation, fine adjustment of 0.2mm per rotation
With flare prevention, Built in UV cut filter
Field diaphragm: dialing continuous variable (centerable), Aperture diaphragm: dialing continuous variable (centerable)
Filter: Double turret (ND16, ND4/GIF, NCB, Additional option available), Polarizing block (Selectable with or without 1/4λPlate)
Fluorescence filter blocks: B/G/V/BV, Built in 12V50W halogen lamp, C-HGFI HG Fiber Illuminator
Eyepiece tube/Back port: 100/0, 55/45
CFI60 Optics
Erect
Bright/Darkfield/Simple Polarizing/DIC/Epi-Fluorescence
MA2-NUI5: Bright/Darkfield/DIC 5 position nosepiece, LV-NU5A: Motorized Bright/Darkfield/DIC 5 position nosepiece
D-NID6: Bright/Darkfield 6 position nosepiece (Intelligent), D-NI7: Brightfield 7 position nosepiece (Intelligent)
MA2-SR Mechanical Stage (X/Y flexible handle)
Dimension: 295x215mm, Stroke: 50mmx50mm (with distance graduation), Standard accessory:φ22 universal specimen holder (with sample clip)
Seidentopf, Interpupillary Distance Adjustment 50-75mm
100-240V, 50-60Hz
1.2A 50/60Hz
1.2A 75W
26kg

Option
Intermediate magnification
Scale

Turret (1x, 1.5x, 2x), Status detection (Output magnification information to main unit)
MA2-GR Grain Reticle (ASTM E112-63 grain sizing numbers 1 to 8), Grid Reticle(20 lines, 0.5mm)
MA2-MR Scale Reticle (compatible with 5-100x, Read in um, Dialing System)

Specifications (MA100)
Optics
Observation image
Observation method
Focusing
Nosepiece revolver
Stage

Illuminator
Binocular body
with photo tube
Electrical specification
Lamp
External dimensions
Weight

CFI60 LU system
Upright reversed image
Brightfield and polarization (with MA P/A simple polarizer/analyzer set)
Focusing nosepiece (fixed stage)
Coaxial coarse/fine adjustment knob with 8.5-mm stroke (Coarse adjustment of 37.7mm per turn, fine adjustment of 0.2mm per turn)
Brightfield 5-position nosepiece
MA-SP Plain Stage: 170 x 230mm - Includes two stage inserts (1) clear acrylic stage insert with φ30mm opening, (2) clear acrylic stage insert with crescent opening
(width 30mm) to allow clearance for rotation of high magnification objectives
Optional stage inserts: MA-SRSH1 Specimen Holder 1 with 15mm opening or MA-SH3 Specimen Holder 3 with 2mm to 32mm adjustable opening
Accepts Attachable Mechanical Stage TI-SM
TI-SM Attachable Mechanical Stage CH for use with Plain Stage: 126mm x 80mm stroke, handle can be attached on the right or left side of the plain stage
Optional Specimen Holders to fit Attachable Mechanical stage: MA-SH1 Specimen Holder 1 (φ15mm opening)
MA-SH2 Specimen Holder 2 (φ30mm opening), or C-HU Universal Holder (30mm to 65mm adjustable opening)
MA-SR Rectangular 3-plate Stage: 50 x 50 mm stroke (includes two stage inserts (φ20mm and 40mm opening) and coaxial control handle on the right side
The 3-plate design allows entire top surface to move. Optional Stage inserts: MA-SRSH1 Specimen Holder 1 with (φ15mm opening or MA-SH3 Specimen Holder 3
with 2mm to 32mm adjustable opening
Internal power supply 6V 30W Halogen Lamp (long-life type)
Condenser built-in (lever operated) φ25mm filter (includes NCB11 and ND4) can be inserted
Built-in Siedentopf binocular
45° inclination angle and 50 to 75-mm interpupillary adjustment; photo tube accepts ISO type CCTV/Digital Camera "C" mount adapters
Light path knob switches between 100% visual and 20% visual: 80% photo
Input: 100v/110v/120v, 220v/230v/240v 50-60Hz; Output: 1.5v to 6v; Max. power consumption: 96VA
6V 30W Halogen
228 x 663 x 382 mm (W x D x H)
Approx. 9kg

Specifications and equipment are subject to change without any notice or obligation on the part of the manufacturer. October 2008 ©2006/2007/2008 NIKON CORPORATION
The products detailed in the brochure are controlled by the Japanese Foreign Exchange and Foreign Trade Law and the International Export Control Regime. If there is a possibility that they may be utilized
for the development of weapons of mass destruction, etc., they shall not be exported without authorization from the government.

NIKON CORPORATION
6-3, Nishiohi 1-chome, Shinagawa-ku,
Tokyo 140-8601, Japan
phone: +81-3-3773-9026 fax: +81-3-3773-9062
http://nikon.com/products/instruments/index.htm

NIKON INSTRUMENTS INC.
1300 Walt Whitman Road, Melville, N.Y. 11747-3064, U.S.A.
phone: +1-631-547-8500; +1-800-52-NIKON (within the U.S.A. only)
fax: +1-631-547-0306
http://www.nikoninstruments.com/
NIKON INSTRUMENTS EUROPE B.V.
Laan van Kronenburg 2, 1183 AS, Amstelveen, The Netherlands
phone: +31-20-44-96-222 fax: +31-20-44-96-298
http://www.nikoninstruments.eu/
NIKON INSTRUMENTS (SHANGHAI) CO., LTD.
CHINA phone: +86-21-5836-0050 fax: +86-21-5836-0030
(Beijing branch) phone: +86-10-5869-2255 fax: +86-10-5869-2277
(Guangzhou branch) phone: +86-20-3882-0552 fax: +86-20-3882-0580

Printed in Japan (0810-10) Am/M

NIKON SINGAPORE PTE LTD.
SINGAPORE phone: +65-6559-3618 fax: +65-6559-3668
NIKON MALAYSIA SDN. BHD.
MALAYSIA phone: +60-3-78763887 fax: +60-3-78763387
NIKON INSTRUMENTS KOREA CO., LTD.
KOREA phone: +82-2-2186-8410 fax: +82-2-555-4415
NIKON CANADA INC.
CANADA phone: +1-905-625-9910 fax: +1-905-625-0103
NIKON FRANCE S.A.S.
FRANCE phone: +33-1-45-16-45-16 fax: +33-1-45-16-00-33
NIKON GMBH
GERMANY phone: +49-211-9414-0 fax: +49-211-9414-322
NIKON INSTRUMENTS S.p.A.
ITALY phone: +39-55-3009601 fax: +39-55-300993
NIKON AG
SWITZERLAND phone: +41-43-277-2860 fax: +41-43-277-2861

Code No. 2CE-KGSH-1

NIKON UK LTD.
UNITED KINGDOM phone: +44-20-8541-4440 fax: +44-20-8541-4584
NIKON GMBH AUSTRIA
AUSTRIA phone: +43-1-972-6111-00 fax: +43-1-972-6111-40
NIKON BELUX
BELGIUM phone: +32-2-705-56-65 fax: +32-2-726-66-45

Inverted Metallographic Microscopes

Front Operation
All controls are on the front of the instrument.
Delivers ease-of-use by placing all important controls on the front.
Quick Status Check
1
Optical path changeover lever
(vertical tube/binocular tube)

2

Single-action operation

Nosepiece
Aperture diaphragm dial

3

Field diaphragm dial

4

10

6
7

5
Operation port for the
polarizer/analyzer unit
and the fluorescent unit

Analyzer/polarizer interlock mechanism

8

Brightness control dial

BD field changeover lever

9

Scale slider slot
Flexible handle stage

Display

Automatically detects the
address of the objective lens
currently in use and displays
it on the main unit front panel.

Compact built-in design
Employs internal turrets that keep dust off the illumination
filters, maintaining bright uniform illumination. Also, the
power supply is built in to save space.

Links the attachment/release of the analyzer/polarizer.

Brightfield/Darkfield auto-aperture switching
The field stop and aperture stop automatically open when switched
from brightfield to darkfield. When returning to brightfield observation,
the previous field and aperture stop settings are reproduced.

Brightfield

Darkfield

Aperture settings
are kept

Aperture opens
simultaneously

Flash prevention mechanism
Reflection flashes when switching objective lenses are automatically
prevented.

Box Structure

600

Smaller footprint than conventional models:
Three times free spaces left!
Improved durability thanks to the unique box structure.
597

341

Compact structure with a depth of 315 mm
A box shaped microscope, not only the width but also the depth is reduced
dramatically: The foot print is only one-third of the conventional model!

High stability/durability

315

New solution from Nikon: An ideal new microscope

The observation position of the objective lens and sample can be
checked easily from the microscope’s front panel.

TME300

Vibration during high-power observation is reduced. Extremely high rigidity.

(Conventional model)

High Performance
Basic performance dramatically improved. Provides a more ergonomic and clear image observation.
Super-wide field of view
The ultra wide field of view eyepiece and
with the combination of the newly
developed 1x objective lens, a sample of
25mm diameter can be observed in an
one field of view.

Even Illumination
ø25mm

Improved uniformity of illumination delivers clear images, especially
for digital imaging

ø13.3mm
Combine up to eight images
with the stitching feature
Conventional model’s field

MA200's field

Combine up to eight images with
the stitching feature. Get natural
looking images with uniform
lighting and no seams.

CFI60 optics
Nikon’s world-class CFI60 optics, which provide clear, high-contrast
brightfield images and darkfield images with three times the
brightness of conventional models. New 1x and 40x objective
lenses have been added to the line up.

2

Energy saving
The 50W halogen light source realizes the same brightness as the
previous 100W light source with only about half the power
consumption.

3

Introducing a durable, user-friendly Inverted
Microscope with, superior image quality,
a small footprint, and great cost performance

Cost-effective microscopy, now simpler than ever

The ECLIPSE MA100 is a compact inverted microscope specially designed to meet the needs of reflected light
observations requiring either brightfield or simple polarization illumination techniques. Its small foot-print,
durable construction, simple operation, and superior Nikon optics, make it an ideal bench-top solution for:
metallurgical samples, electronic components, failure analysis, materials science and quality control/quality
assurance applications.

Stage

CFI60

Stable control even with heavy samples
A newly developed stage boasting superior durability

Sharp, clear images using CFI60 optics

Nikon developed the new MA-SR Rectangular Stage especially
for the MA100. The three-plate structure gives the microscope
superior control and durability for observation of heavy samples,
such as a grinder resin
mounted samples.

Nikon’s proprietary CFI60 System optics provide high Numerical
aperture and longer working distance. CFI60 LU optics deliver
bright, high-resolution images with superior contrast. The built-in
photo port, makes the MA100 ideally suited for digital image
capture. The built-in nosepiece
turret mounts up to five
objective lenses for a complete
range of magnifications.

Aperture Diaphragm

Mirror

Aperture diaphragm comes standard

Identify objective magnification at a glance

The epi illuminator comes standard with a variable aperture
diaphragm to control image contrast and depth of field.

The ECLIPSE MA100 incorporates a unique feature, a mirror to
check under the stage. Now users can verify what objective lens
is being used as well as the
position of the sample without
having to look beneath the
stage.

Polarizer/Analyzer
Simple polarization with a single-action polarizer/analyzer mechanism
The MA-P/A Pol Set makes reflected polarized light observation simple. It takes just a single
action to slide the polarizer and analyzer in the light path. The polarizer can rotate 360°
degrees, allowing users to set a polarization direction suited for the sample being observed.
Samples typically observed under polarized light include: plastics, thin-films, metals,
contaminants, chemicals, strain-tested materials, glasses and other materials etc.

4

5

Image Capture
Status Display

DS-L2 camera control unit
Stand-alone type

The calibration data is automatically
changed when the objective magnification
is changed. This feature makes it easy to
use the measurement function in the
DS-L2. Quantitative illumination adjustment
can be made manually by viewing the
voltage value. This is crucial when
acquiring the optimum settings for
observation and image capture.

The built-in, high-definition, large 8.4-inch XGA LCD screen lets you
view & discuss the sample without the need to look in the eyepieces.

Easily save/print data

The ultimate imaging that only Nikon can offer.

MA200 only

Captured images can be saved to USB memory or a CF card. In
addition to printing directly via a PictBridge-compatible printer, you
can save data onto a server over a LAN.

1
2
3
4
1 Objective lens information
2 Nosepiece information
3 Intermediate
magnification information
4 Halogen illumination
information

Image Analysis
DS-U2 camera control unit
PC-controlled type

Imaging software NIS-Elements
Control software
DS-U2 and NIS-Elements allow the user to
perform everything from basic image capture
to the measurement, analysis, and
management of captured images.
*See the NIS-Elements catalog for more information.

Status Display

MA200 only

The calibration data is automatically changed when the
1
objective magnification is changed. This feature makes
the measurement function and other optional software
modules such as grain sizing and cast iron analysis
2
in the NIS-Elements easy to use.
Quantitative illumination adjustment which is crucial when
acquiring the optimum settings for observation, image
capture and especially large image stitching, can be
made via PC control.

1 Objective lens/nosepiece information
2 Illumination information
(halogen lamp/Intensilight)
(Also displays intermediate variable power)

Stitching
Adjacent images can be put together to create
an image with a wide field. It is now possible
to capture even more vivid images due to the
improved uniformity of the illumination.

Grain Size analysis

Option

Detects and measures grains in one and two
phase samples according to JIS G0551or
ASTM E112-96/E1382-97 standards.

Cast Iron analysis

Option

Detects, measures and classifies graphite
content as well as ferrite content in graphitecorrected samples according to JIS G5502
or ASTM A247-06 standards.

Original image

Measurement results include:

Main applications

· G grain size · Grain size by area and/or intercepts
· Number of grains · Anisotropy index
· Other basic grain size statistics

· Graphite shape and size classification
· Nodularity
· Graphite, Ferrite, Pearlite fractions
· Other basic iron analysis statistics
· Customizable functionality includes image masks,
size restrictions and nodule shape classification.

Customizable measurement techniques provided:
Images combined by stitching

· Planimetric

· Linear

· Circular

· Abrams

Camera heads suited to specific applications
Cooled high-definition color camera head
1.27-megapixel 2/3-inch color CCD

6

High-definition color camera head
5-megapixel 2/3-inch color CCD

High-speed color camera head
2-megapixel 1/1.8-inch color CCD

7

Accessories
Holders

Diascopic Unit

Digital Sight Series

Stage+Holders A

We offer a full lineup of
holders.

Accessory required for transmitted
illumination observation.

A flexible system that enables various configurations
consisting of a camera head and a control unit to suit the
needs of each sample or application.

A simple fixed stage.

1
2
3
4

1

1 MA2-DP 100W Pillar

MA2-SRSH Holder Set
MA2-SRSH 10 Holder
MA2-SRSH 40 Holder
MA2-SRSH 25-40 Holder

1

2

3

4

1
2
3
4
5

MA-SP Plain Stage
Acrylic Sample Holder (standard accessory/φ30mm aperture)
MA-SH3 Specimen Holder 3
MA-SRSH1 Universal Specimen Holder
Acrylic Sample Holder
3
(standard accessory/
1
crescent aperture)
4
2

Stage

5

The holder comes with a stage clip that enable sample
rotation. This flexible handle stage delivers high durability
needed to support heavy samples.

Stage+Holders B

1 MA-2 SR Stage

A dual-platform stage.
1 TI-SM Mechanical Stage CH
2 C-HU Universal Holder
3 MA-SH1 Specimen Holder 1
4 MA-SH2 Specimen Holder 2

1

1
2

3
4

Polarizing
Accessory required for
simple polarizing observation.

Stage+Holders C
A triple-platform stage structure lets you use heavy samples.

1 MA2-PA Unit
2 MA2-UPA Unit*
3 MA2-λP λPlate

1 MA-SR Rectangular Stage
2 Specimen Holder (standard
accessory/φ20mm aperture)
3 MA-SH3 Specimen Holder 3
4 MA-SRSH1 Universal
Specimen Holder
5 Specimen Holder (standard
accessory/φ40mm aperture)

*It is suitable for inspecting aluminium sample.

2

1

3

Nosepiece & Magnification Module
Enables communication of objective lens position,
magnification and intermediate magnification module
information with the DS-L2 control unit and NIS-Elements
image software.

DIC
Accessory required for DIC
observation.

Grain Size Reticle
The class of grain size in a sample can be easily
distinguished while observing its image.
1 MA100-EPRGS Grain Size Reticle

1

1

4

2

5

Simple Polarizing
An accessory necessary for simple
polarization observation.

1 MA2-MC Magnification Module
2 MA2-NUI5 Universal Intelligent Quintuple Nosepiece

1 MA2-PA Unit
2 L-DIHC DIC Prism (High Contrast)
3 L-DIC DIC Prism

1

3

1 MA-P/A Simple Polarizer

1

2

1

Objective Lenses

2

CFI60 optics that provide uniform and clear images with both high NA and long working distance.

3

Grain Size Reticle & Scale

Fluorescence

Overlays a pattern onto the observed image. MA2-GR
Grain Size Reticle is used for grain size analysis which is
compliant to JIS G0551 and ASTM E112 standards.
The MA2-MR Scale is used for scale display for each
objective magnification.

Accessory required for fluorescence observation.
1
2
3
4

MA2-FL FL G
MA2-FL FL B
MA2-FL FL BV
MA2-FL FL V

2
1

Type
CFI L Plan EPI

CFI LU Plan Fluor EPI

1
CFI LU Plan EPI ELWD

1 MA2-GR Grain Size Reticle
2 MA2-MR Scale
4
3

8

1 CFI L Plan EPI 1x, 40x

1

2

CFI L Plan EPI SLWD

Power Numerical aperture (NA) Working distance (W.D.)(mm)
1x*
0.03
3.8
2.5x
0.075
8.8
40x
0.65
1.0
5x
0.15
23.5
10x
0.30
17.5
20x
0.45
4.5
50x
0.80
1.0
100x
0.90
1.0
20xA
0.40
13.0
50xA
0.55
10.1
100xA
0.80
3.5
20x
0.35
24.0
50x
0.45
17.0
100x
0.70
6.5

Type
CFI LU Plan Apo EPI
CFI LU Plan Fluor BD

CFI LU Plan BD ELWD

CFI LU Plan Apo BD

Power Numerical aperture (NA) Working distance (W.D.)(mm)
100x
0.95
0.4
150x
0.95
0.3
5x
0.15
18.0
10x
0.30
15.0
20x
0.45
4.5
50x
0.80
1.0
100xA
0.90
1.0
20xA
0.40
13.0
50xA
0.55
9.8
100xA
0.80
3.5
100x
0.90
0.51
150x
0.90
0.4

*When using CFI L Plan EPI 1x with MA100 and MA200, the following accessories
are required. "MA2-PA Unit" when using with MA200 and "MA-P/A Simple
Polarizing Set" when using with MA100. (Sales will start in January 2009)

9

System Diagram (MA200)
ENG-mount CCD Camera

ENGmount
Adapter
0.45x
0.6x

ENGmount
Adapter

C-mount CCD Camera
C-mount
Adapter
0.35x
C-mount
C-mount 0.45x
0.6x
TV Adapter A
Adapter
0.7x

C-mount
Zoom

ENGmount
Zoom

TV Zoom
Lens

Relay
Lens 1x

System Diagram (MA100)
Digital Camera System for Microscopy
Digital Sight Series

TI-SM
Mechanical Stage CH
C-mount
Adapter
0.7x

Filter φ45mm

MA-SH1
Specimen Holder 2

Filter 45mm GFI
Filter 45mm NCB11

Relay
Lens
1x

MA-SRSH1
Universal
Specimen Holder

Filter 45mm ND2 A
Filter 45mm ND16 A

MA-SH3
Specimen
Holder 3
C-Mount
TV Adapter A

12V100W
Lamp
C-mount
Adapter
VM4x

C-mount
Adapter
VM2.5x

V-T Photo
Adapter

T-P2
DIC Polarizer

MA-SH2
Specimen Holder 2
D-LH/LC
Lamphouse W/LC

C-mount
Adapter
0.55x

LV-TV
TV Adapter

MA100-EPRGS
Grain Size Reticle

TI-PS 100W
PS100-240

Y-TB
Binocular Tube

CFI
CFI
CFI
CFI
10xM 10xCM 12.5x 15x

C-CT
Centering
Telescope

C-W15x
DS-L2

TI-C
Condenser
Turret

Measurement
Telescope
CFI
UW
10xM

CFI
UW
10x

TI-C-LWD
LWD Lens

Adapter

F

LU Plan Fluor EPI
Objective Lens

TE-C
ELWD-S
Condenser

LU Plan EPI
Objective Lens
ELWD, APO

MA2-MP
Monitor Pillar
(Interface cable
included)

GIF Filter

L Plan EPI
Objective Lens
1x*1, 2.5x, 40x,
SLWD, CR

MC TMD2
ELWD Lens

6V30W
Halogen Lamp

LV-HL50W
12V-50W-LL Lamp

A

MA2-UPA Unit
(Polarizer + Analyzer +
1/4 λPlate)

●100V/120V
●230V

LV-LH50PC
12V50W
Lamphouse

B

MA2-FL Unit
(G,B,BV,V Excitation)

C

C

MA2-MC
Magnification Module

*1: When using CFI L Plan EPI 1x with MA100 and MA200, the following accessories are required.
"MA2-PA Unit" when using with MA200 and "MA-P/A Simple Polarizing Set" when using with MA100. (Sales will start in January 2009)

C-LHGFI
HG Lamp

D
LV-HGFA
HG Fiber
Adapter

C-HGFIF
HG Fiber (1.5m/3m)

MA2-GR Grain Size

D

MA-P/A
Simple Polarizing Set

Inverted Metallurgical Microscope

E

C-ER
Eyelevel Riser

MA2-PA Unit
(Polarizer + Analyzer)

C-W10xB

(Includes two
specimen holders)

C-HU
Universal Holder

MA2-TI3
Trinocular
Tube TI3

MA-TT2
Tilting Trinocular Tube*1

CFI
10x

(Includes two holders
for acrylic samples)

E
F
E
F

MA-SR
Rectangular Stage

MA-SP Plain Stage

MA2-DP
100W Pillar

F

C-Mount
Adapter 0.7x

C-HGFI
Fiber Light Sourse
(Manual)

Dimensions

C-HGFIE
Fiber Light Sourse
(Motorized)

MA2-MR Scale

MA2-λP λPlate

50

118

210

118

210

MA-SRSH1
Holder

MA2-SR
Stage

MA-SRSH
25-40 Holder

118

MA-SRSH 10
Holder

124

228

MA-SRSH 40
Holder

MA2-SRSH Holder Set (Guide type)

521

Standard
Holder φ22
(Comes standard)

φ36
(φ39)
for 1 1/2"

φ30
(φ33)
for 1 1/4"

170

493

φ23
(φ26)
for 1"

LU Plan EPI
Objective Lens
ELWD, APO

LV-DIHC Slider
(High Contrast)
Position A&B

W

W

L-DIC
DIC Prism
318

LV-NCNT2
Nosepiece
Controller

*1: Built to order.
*2: When using CFI L Plan EPI 1x with MA100 and MA200, the following accessories are required.
"MA2-PA Unit" when using with MA200 and "MA-P/A Simple Polarizing Set" when using with MA100. (Sales will start in January 2009)

205
123

A

10

673

57

341

15.5

315

188

167

W

LV-NU5A
Universal
Motorized
Quintuple
Nosepeice

309

V

MA2-NUI5
Universal
Intelligent
Quintupule
Nosepeice

L-DIHC
DIC Prism
High Contrast

308

U

D-NI7
Intelligent
Septuple
Nosepiece

4

V

D-DA
DIC Analyzer

S

3

D-LPλ Plate

D-NID6
Intelligent
Sextuple
DIC Nosepiece

2

U

174
230

90

LU Plan BD
Objective Lens
ELWD, APO

400

LU Nosepiece
Adapter
M32-25

LV-DIC Slider
Position A&B

228

B
LU Plan
Fluor BD
Objective Lens

120

S

LU Plan
Fluor EPI
Objective Lens

226

L PLAN EPI
Objective Lens
1x*2, 2.5x, 40x,
SLWD, CR

124

45

110

231

11



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : 3.1-702
About                           : uuid:f9519bbc-90ea-11dd-b0c7-000a95a109b6
Producer                        : Acrobat Distiller 4.0 for Macintosh
Modify Date                     : 2008:10:10 10:34:33-04:00
Create Date                     : 2008:10:03 10:20:57Z
Metadata Date                   : 2008:10:10 10:34:33-04:00
Document ID                     : uuid:c4dc7931-90ea-11dd-b0c7-000a95a109b6
Instance ID                     : uuid:c50359b8-19d9-429d-bec3-cac307e2edb6
Format                          : application/pdf
Page Count                      : 6
EXIF Metadata provided by EXIF.tools