Ningbo EverFlourish Smart Technology 200ULRF Remote control transmitter User Manual

Everflourish Electrical Co., Ltd. Remote control transmitter Users Manual

Users Manual

Download: Ningbo EverFlourish Smart Technology 200ULRF Remote control transmitter User Manual
Mirror Download [FCC.gov]Ningbo EverFlourish Smart Technology 200ULRF Remote control transmitter User Manual
Document ID1089602
Application IDKTjzZbI2B2LsCaK4aQOyAQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize2.29kB (28588 bits)
Date Submitted2009-04-02 00:00:00
Date Available2009-04-03 00:00:00
Creation Date2009-03-30 16:33:04
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2009-03-30 16:33:04
Document TitleMicrosoft Word - EMW200R-UL _fit with transmitter EMW200T_ manual-Eng.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: wakeyouw

Instruction Manual for
RF Remote Control Socket and Transmitter
EMW200R-UL, the remote control socket
EMW200T, the hand held transmitter
As always follow electrical safety precautions, do not use with unattended appliances or those involving
heating elements.
Function
1. The remote control socket (EMW200R-UL) turns on and off the connected lighting or appliance by a wireless
transmitter (EMW200T) using radio frequency up to 25 meters away.
2. It is ideal for controlling lighting for the purposes of home automation and energy saving.
3. Each transmitter controls up to 3 channels. Each channel can command up to 3 receivers.
Operation
1. Check the group setting at the back of the transmitter, A, B, C or D. If the transmitter is in group A, then, the
commanded receiver has to be in the same group setting.
2. Check the group setting at the back of the receiver is same as transmitter and the channel no, eg. A1, A2 or A3
3. Connect the remote control socket to the mains power supply.
4. Press the corresponding “ON”, “OFF” buttons on the transmitter to switch on and off the connected appliance by
remote control. (eg. on/off buttons 1 controls receiver A1, 2 controls receiver A2, 3 controls A3)
5. The indicator on the receiver blink once for every reception of power on/off
Caution
1. For safety reason, always switch off your appliance before connection.
2. Appliances to be connected to the remote control socket MUST NOT exceed the voltage and frequency ratings
as in “Specifications”.
3. User can adjust the channel group on the transmitter and socket receiver at any time. And to change the group
setting, eg. From A1 to A2, or to A3, in order to change the control button position on the transmitter.
4. To adjust the channel or the groups, always use a big screw driver with the same diameter as the adjustment
arrow at the back of the socket and receiver. A small screw driver will deform the plastic housing during
adjustment.
Specifications
EMW200R-UK
1. Power Rating : 125V~, 8A, 1000W resistive, 625W tungsten
2. Frequency: : 433.92 MHz,
3. Distance:
: 25 meters max. (open area)
EMW200T
1. Battery
2. Frequency
3. Distance
: 23A 3L R50 12V
: 433.92 MHz
: 25 meters max. (open area)
Radio Frequency Interference Statement
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference and
(2) this device must accept any interference received, including interference that might cause undesired operation.
Changes or modifications not expressly approved by the manufacturer could void the user’s authority to
operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
—Consult the dealer or an experienced radio/TV technician for help.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : wakeyouw
Create Date                     : 2009:03:30 16:33:04+08:00
Modify Date                     : 2009:03:30 16:33:04+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Title                           : Microsoft Word - EMW200R-UL _fit with transmitter EMW200T_ manual-Eng.doc
Creator                         : wakeyouw
Document ID                     : uuid:aec6de11-ff31-4699-91aa-f99825b079a2
Instance ID                     : uuid:7f18e0c9-91f3-4896-9a44-64957ee9f785
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: VBA-200ULRF

Navigation menu