Nokia Solutions and Networks CPE25725 WiMAX CPE User Manual CPEi25725UM
Nokia Solutions and Networks WiMAX CPE CPEi25725UM
User Manual
Table of Contents Contents Chapter 1: Desktop CPEi 725 User Guide Overview . . . . . . . . . . . . . . . . . . . . Powerful Features in a Single Unit Front of the CPE . . . . . . . . . . . . . . . Back of the CPE . . . . . . . . . . . . . . . Operating Information . . . . . . . . . . .... .... .... .... .... .... .... .... .... .... ... ... ... ... ... ................................. ................................. ................................. ................................. ................................. 1-1 1-1 1-2 1-2 1-3 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Before you Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Easy Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Advanced Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Procedure to Log into the CPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setup Wizard and Authentication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2-1 2-1 2-2 2-2 2-3 Chapter 2: Installation Chapter 3: Basic Configuration Personalize Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Password Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Device Time Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Device Name Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Restore Factory Settings Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internet Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WiMAX Security Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Firewall Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dynamic DNS Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Status Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Telephony Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3-2 3-2 3-2 3-3 3-3 3-4 3-4 3-5 3-5 3-6 Chapter 4: Advanced Configuration Port Forwarding Menu Forwarding Tab . . . . . Local Address Menu . . DHCP Server Tab . . . . Lease Status Tab . . . . Lease Reservation Tab Control Panel . . . . . . . Software Tab . . . . . . . Certificate Tab . . . . . . System Tab . . . . . . . . . ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... 4-1 4-2 4-2 4-3 4-4 4-4 4-5 4-6 4-6 4-6 About Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Chapter 5: Configuring TCP/IP Configuring TCP/IP in Windows 2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 Configuring TCP/IP in Windows XP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5 Chapter 6: Troubleshooting Power LED is Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Computer Cannot Log On to the CPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cannot Connect to the Internet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Additional Troubleshooting Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 6-1 6-1 6-1 This Product complies with the following RF energy exposure standards and guidelines: . . RF Exposure Compliance and Guidelines Operating Instructions . . . . . . . . . . . . . . . . . . . . . FCC Regulatory Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Industry Canada Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EU Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Caring for the Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Disposal of Motorola Equipment in EU Countries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Disposal of Motorola Networks Equipment in Non-EU countries . . . . . . . . . . . . . . . . . . . . . CMM Disclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Copyrights and Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Copyrights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Usage and Disclosure Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 7-1 7-1 7-2 7-3 7-3 7-4 7-4 7-4 7-5 7-5 7-5 Chapter 7: Important Safety and Legal Information Desktop CPEi 725 User Guide Chapter 1: Desktop CPEi 725 User Guide Overview Uibol!zpv!gps!qvsdibtjoh!uif! Npupspmb!DQF!Joepps!)DQFj*! 836!eftlupq!efwjdf/!Uif! Eftlupq!DQFj!bmmpxt!zpv!up!dpoofdu!up!uif!xjsfmftt!xpsme!fbtjmz!boe!tfbnmfttmz! xjuipvu!dpnqmjdbufe!jotubmmbuj po!boe!tfuvq!qspdfevsft/!Jo! beejujpo-!ju!pggfst!zpv!uif! bcjmjuz!up!nblf!Wpjdf!pwfs!Joufsofu!Qspupdpm!)WpJQ*!dbmmt/ Uif!Eftlupq!DQF!joepps!)DQFj* !efwjdf!qspwjeft!uif!vtfs; Ǹ Dpowfojfodf!.!xjui!fbtz!qmvh!boe! qmbz!gvodujpobmjuz/!Dpnqbdu!eftjho/ Ǹ Dpouspm!.!sfnpuf!nbobhfnfou!dbqbcjmjuz!bmmpxt!fbtz!efufdujpo!boe!bvuifoujdbujpo! podf!uif!voju!jt!tfu!vq/! Ǹ WpJQ!.! Pof!SK22!qpsut!bmmpx!gps!Wpjdf!pwfs!JQ!dbmmt!vtjoh!zpvs!DQFj!836/ Uif!gfbuvsft!boe!uif!qiztjdbm !bqqfbsbodf!pg!zpvs!Eftlup q!DQFj!efwjdf!nbz!ejggfs! tmjhiumz!gspn!uif!jmmvtusbujpo/! Gjhvsf!2.2;! DQFj 836 Gps!uif!nptu!sfdfou!epdvnfoubujpo-!wj xxx/npupspmb/dpn/ tju!uif!Qspevdu!Epdvnfoubujpo!qbhf!po! Powerful Features in a Single Unit Uif!DQF!efwjdf!qspwjeft!uif!gpmmpxjoh!gfbuvsft; Ǹ XjNBY!Bvuifoujdbujpo Ǹ XBO!EIDQ!Dmjfou Ǹ MBO!EIDQ!Tfswfs Ǹ Ipnf!Hbufxbz!Gvodujpot Ǹ Gjsfxbmm!Qspufdujpo Ǹ Qpsu!Gpsxbsejoh 1-1 1 Desktop CPEi 725 User Guide Front of the CPE The front of the CPE unit contains LED Link/Activity indicators. The LEDs provide the status of the unit and signal strength indicators for easy adjustment during setup. Table 1-1 LED Indicator Interface LED Status Signal Strength Full WiMAX Signal Strength is detected when all WiMAX Signal Strength LEDs are lit. • All WiMAX Signal Strength LEDs are off - very low signal detected. • One to two WiMAX Signal Strength LEDs are lit - low signal detected. • Three to five WiMAX Signal Strength LEDs are lit - high signal detected. WAN WiMAX While acquiring access to the WiMAX Network: • All WiMAX Signal Strength LEDs vary between ON, OFF and/or BLINKING status. CAUTION If all five WiMAX Signal Strength LEDs are blinking, then a software upgrade is in progress. Do NOT remove power to the CPE. Back of the CPE The back of the CPE unit contains the reset switch, AC Power Connector, Ethernet connector, Ethernet LED and telephone 1-2 port. Desktop CPEi 725 User Guide Gjhvsf!2.3;! DQF!Qpsut!boe!Dpoofdujpot Qipof!2!)WpJQ* Fuifsofu Dpoofdups Bebqufs Dpnqvufs BD!Qpxfs Dpoofdups DQF j836 Table 1-2 Port Descriptions Port Port Description Fuifsofu Fuifsofu!Qpsu Qpxfs BD!Qpxfs!Dpoofdups Sftfu Ibsexbsf!Sftfu!Cvuupo!)B!qbqfsdmjq!jt! sfdpnnfoefe!gps!bddfttjoh!uijt!cvuupo*/ Qipof!Mjof! SK.22!qpsu!gps!vtf!xjui!WpJQ/ Operating Information Pqfsbujoh!ufnqfsbuvsf!gps!uijt!voju!jt!1.51 °D!)43.215 1-3 °G*/ 1 1-4 Desktop CPEi 725 User Guide Installation Chapter 2: Installation Overview To install the Desktop CPEi • • 725 Series, review the following sections: Before You Begin Easy Setup Before you Begin Before you begin installation, check that you have received the following items with your Desktop CPEi 725: Table 2-1 In the box with your CPE, you should have Item Description AC Adapter Power adapter and cord connects the Desktop CPE to an AC electrical outlet. Ethernet Cable The Ethernet cable connects the Internet port on your Desktop CPE to your PC or laptop computer. Desktop CPEi 725 Quick Start Guide Desktop CPEi 725 Quick Start Guide In addition, you need: • A computer • An RJ-11 telephone cable (optional). Two RJ-11 telephone cables are required if your service provider has supplied you with two telephone numbers. Easy Setup The CPE is easily set up in your home. Basic installation equipment needed are the power adapter and cord, Ethernet cable, a PC or laptop computer and the CPE device. If you want to use the VoIP functionality, you need an RJ-11 phone cable and a telephone. Perform the following tasks before attaching the power cord or powering up the unit: • Stand the CPE on a flat surface. • Plug the power adapter into the power connector on the back of the unit. • Plug the AC power cord into an AC outlet. • Plug one end of the Ethernet cable into the Ethernet connector on the back of the unit. • Plug the other end of the Ethernet cable into the Ethernet connector of your computer. • To use VoIP functionality of the phone, plug one end of the phone line into the activated phone connector on the back of the unit. Phone line activation is dependent upon your service contract. • Plug the other end of the phone line into the phone line connector of your telephone. 2-1 2 Installation Advanced Setup The CPE can also be used to connect to a multi-port switch (hub) - purchased separately from the CPE. Connecting the CPE device to a hub allows you to connect more than one computer to your CPE device. Procedure to Log into the CPE Before you Begin Configuration Some settings on your computer need to be verified or changed to ensure that your computer configuration can support the Desktop CPE. Verify that the IP addresses and DNS settings are automatically generated in your Local Area connection of your Internet Protocol (TCP/IP) properties. Refer to the chapter titled “Configuring TCP/IP” for additional information. Logging in to the CPE Use the following procedure to log into the Desktop CPE: 1. On a computer that is connected to the Desktop CPE, open a web browser. 2. In the Address or Location field, type http://mywimax. and press ENTER to display the login screen. Include the period (.) after http://mywimax. in order to access the login screen. NOTE Enter the IP address: http://192.168.15.1 into Address field in order to gain access to your CPE. If you cannot access the CPE, refer to the chapter titled: Configuring TCP/IP for more information. 3. 2-2 The Welcome to Motorola WiMAX CPE screen is displayed and prompts you for a password. Installation Figure 2-1: Login Screen 4. 5. 6. 7. In the Password field, type the password (default is motorola). Click Login. First time users see a pop-up box that states: “The Wizard application will guide you through for the first time configuration”. Click OK button to continue. Click the OK button to launch the wizard application. Setup Wizard and Authentication Step 1 - Change Password Once you have launched the setup wizard, you are prompted to change your password. Motorola recommends using a password to protect your home network and CPE device. Passwords are case sensitive. To change your password: • Ensure the “Enable Login Password Protection” box is checked. • Enter a New Login Password in the box. Passwords can be no more than 20 characters in length. • Re-type your new password in the Confirm New Login Password box. • Click Next. If you forget your password, you can reset it back to the default (motorola) password. To reset the password, press and hold the reset button on the back of your CPE for 5 or more seconds. Before resetting the CPE, ensure that the power is ON. Step 2 - Device Time This screen allows you to set the time zone and to enable Daylight Savings Time (when applicable) for your location. • Select the appropriate time zone for your location from the drop-down box. 2-3 2 Installation • • Check the box that is called “Auto Adjust for Daylight Savings Time” if you live in a region that observes Daylight Savings Time. This box is checked by default. Click the Next button. Step 3 - WiMAX Security The WiMAX Security tab contains your authentication method. Check with your service provider to determine if they require a user name and password for authentication purposes. • If the Authentication Method is EAP-TLS, no User Name and Password are required. Enter the Realm information supplied by your service provider. Click the Next button. • If the Authentication Method is EAP-TTLS/MS-CHAPv2, enter a User Name and Password, and Realm information supplied by your Service Provider. Once you have entered the User Name/Password/Realm information, click the Next button. • If you are unsure of the Authentication Method, select EAP-TLS (which is the default) and click the Next button. Step 4 - Account The Account tab allows you to manage Voice over IP (VoIP) related services. Please consult with your telephony service provider for these settings. Click the Apply button when finished. Congratulations! You have now completed the setup of your WiMAX connection. Click OK on the Congratulations! dialog box. A status screen appears that shows Network status and telephony status. The Network Status screen provides any status associated with your WiMAX Wireless Broadband connection. The Telephony Status screen provides status of your telephony service. • The Restart button is used to restart the device. The restart button is available on every screen. • The Wizard button starts the set-up wizard over again. • The Refresh button refreshes the screen with the current status. • The Auto Refresh button allows the web browser to automatically refresh at the interval determined in the Control Panel menu. 2-4 Installation Figure 2-2: Status Screen Restart Button Figure 2-3: Restart Button 2-5 2 2-6 Installation 68P09292A81-B JUN 2008 Basic Configuration Chapter 3: Basic Configuration Once the CPE setup has been completed, you can log in to your CPE from any computer on your home network. To log in type the device name in the address bar on your computer. The default device name is mywimax. This section describes the PERSONALIZE, INTERNET, and STATUS Menus that are available. Personalize Menu The Personalize menu provides the following tabs: • Password • Device Time • Device Name • Restore Factory Settings Figure 3-1: Personalize Menu 3-1 3 Basic Configuration Password Tab The password tab allows you to enable/disable password protection. You can also change your password here. Be sure to click the Apply button when finished Table 3-1 Password Tab Field or Button Description Enable Login Password Protection Checking this box requires login password protection. New Login Password Enter your new password here. Maximum 20 characters. Passwords are case sensitive. Confirm New Login Password Re-enter your new password here, exactly as entered in the previous step. Device Time Tab The Device Time tab allows you to establish the time zone for your location. It also allows you to automatically adjust for Daylight Savings Time if necessary. Be sure to click the Apply button when finished. Table 3-2 Device Time Tab Field or Button Description Current Local Time Current Local Time Time Zone Select your local time zone from the dropdown box. Auto Adjust for Daylight Saving Time Check this box if your location observes Daylight Savings Time. (Default is checked) Device Name Tab The Device Name tab allows you to rename your CPE device. The Device Name is the name you enter on an internet browser address bar to access your CPE device. Be sure to click the Apply button when finished. Table 3-3 Device Name Tab 3-2 Field or Button Description New Device Name Enter the new name for the CPE device. Maximum 20 characters. Basic Configuration Restore Factory Settings Tab The Restore Factory Settings Tab resets your CPE to the manufacturers default settings. Be sure to click the Apply button if you are sure that you want to reset factory settings. Table 3-4 Restore Factory Settings Tab Field or Button Description Restore Factory Settings Checking this box restores the CPE to factory default settings. The device restarts when you click Apply. Internet Menu The Internet menu provides the following tabs: • WiMAX Security • Internet Protocol • Firewall • Dynamic DNS Figure 3-2: Internet Menu 3-3 3 Basic Configuration WiMAX Security Tab The WiMAX Security tab contains your authentication method. Check with your service provider to determine a user name and password are required for authentication purposes. Table 3-5 WiMAX Security Tab Field or Button Description Authentication Method Drop down box allows you to select either EAP-TLS (default) or EAP-TTLS/MSCHAPv2. User Name (EAP-TTLS/MS-CHAPv2 only) Enter the User Name supplied by your service provider. Password (EAP-TTLS/MS-CHAPv2 only) Enter the Password supplied by your service provider. Realm Supplied by your service provider. If your authentication method is EAP-TLS, then a User Name and Password are not necessary. Click the Apply button. Internet Protocol Tab Please check with your service provider for these settings. If you are unsure of the settings, leave the default values set and click the Apply button. If your service provider has instructed you to change any of these settings, be sure to click the Apply button when you are finished. Firewall Tab A firewall helps to protect your home network from unauthorized access. It also helps to manage authorized access from the internet to your CPE. Table 3-6 Firewall Tab 3-4 Field or Button Description Enable Firewall Check this box to enable the firewall for your home network. Enable Web Login from Internet (Grayed out if Enable Firewall is not selected). Check this box to enables you to access your CPE device from a network other than your own. Web Login Port from Internet Choose a port number to connect to when logging in from a network other than your own. The default is 8080. Basic Configuration Table 3-6 Firewall Tab Field or Button Description Enable ping from Internet Enables the CPE to respond to a ping from the Internet. This option would be enabled to allow testing only. Do not leave this enabled. Be sure to click the Apply button once you are finished. Dynamic DNS Tab Dynamic Domain Name Service (DDNS) allows a user with a non-static IP address to keep their domain name associated with an ever changing IP address. As an example, DDNS is used when you are hosting your own website. Table 3-7 Dynamic DNS Tab Field or Button Description Enable DDNS Check this box to Enable DDNS (default is unchecked). DDNS Service Provider Select DDNS Service Provider that you belong to from the drop-down box. DDNS User Name Only valid if Enable DDNS is checked. Enter your DDNS account user name. DDNS Password Only valid if Enable DDNS is checked. Enter your DDNS account password. DDNS Host Name Only valid if Enable DDNS is checked. Enter the DDNS Host Name. This is assigned by the DDNS service. Be sure to click the Apply button once you are finished. Status Menu The Status menu provides the following tabs: • Network • Telephony 3-5 3 Basic Configuration Figure 3-3: Status Menu Network Tab The Network tab provides any status associated with your WiMAX Wireless Broadband connection. Telephony Tab The Telephony tab provides any status associated with your telephony connection. Telephony Menu The telephony menu allows you to manage your Voice over Internet Protocol (VoIP) services. NOTE Contact your service provider to obtain VoIP service, if you do not already have this service. The Telephony menu provides the following tabs: • Account • Ring Tone • Caller ID • Call Forwarding • Voice Mail • Special Numbers 3-6 Basic Configuration Figure 3-4: Telephony Menu Account Tab Please consult with your service provider for these settings. The Account Tab contains the following settings: Table 3-8 Account Tab Field or Button Description Line 1 User Name If Line 1 is an active VoIP, enter the User Name as provided by your service provider. Line 1 Password Enter the Line 1 password as provided by your service provider. Passwords are case sensitive. Confirm Line 1 Password Reenter your Line 1 password exactly as entered in the field from the previous step. Line 2 User Name If Line 2 is an active VoIP, enter the User Name as provided by your service provider. Line 2 Password Enter the Line 2 password as provided by your service provider. Passwords are case sensitive. Confirm Line 2 Password Re-enter your Line 2 password exactly as entered in the field from the previous step. Be sure to click the Apply button once you have made changes. 3-7 3 Basic Configuration Ring Tone Tab The Ring Tone tab allows you to customize ring tones for your telephone(s). NOTE You need a phone connected to your CPE to hear ring tones. Table 3-9 Ring Tone Tab Field or Button Description Default Line 1 Ring Type Use the drop-down box to select a ring tone for Line 1. The default is ringtone R0. Test Click to hear how the selected ring tone sounds. Default Line 2 Ring Type Use the drop-down box to select a ring tone for Line 2. The default is ringtone R0. Test Click to hear how the selected ring tone sounds. Be sure to click the Apply button once you have made changes. Caller ID Tab The Caller ID tab allows you to manage the Caller ID functions for your telephones: Table 3-10 Caller ID Tab 3-8 Field or Button Description Enable Line 1 Anonymous Incoming Call Rejection If Line 1 is your active telephone port, check this box if you would like to reject telephone calls from anonymous incoming callers. The default is checked. Enable Line 1 Permanent Anonymous Outgoing Call If Line 1 is your active telephone port, check this box if you would like to permanently block your telephone number from appearing on others’ Caller ID. The default is unchecked. Enable Line 2 Anonymous Incoming Call Rejection If Line 2 is your active telephone port, check this box if you would like to reject telephone calls from anonymous incoming callers. The default is checked. Basic Configuration Table 3-10 Caller ID Tab Field or Button Description Enable Line 2 Permanent Anonymous Outgoing Call If Line 2 is your active telephone port, check this box if you would like to permanently block your telephone number from appearing on others’ Caller ID. The default is unchecked. Be sure to click the Apply button once you have made changes. Call Forwarding Tab The Call Forwarding tab allows you to manage the call forwarding features for your telephone(s). The Call Forwarding tab contains the following: Table 3-11 Call Forwarding Tab Field or Button Description Enable Line 1 Basic Forwarding Check this box to enable basic call forwarding on Line 1. The default is unchecked. Line 1 Basic Forwarding to Number If “Enable Line 1 Basic Forwarding” is checked, enter the telephone number you would like to forward calls to. Enable Line 1 Forwarding on No Answer Check this box to forward calls received on Line 1 if there is no answer. This function is not available if “Enable Line 1 Basic Forwarding” is checked. Line 1 No Answer Forwarding to Number If “Line 1 No Answer Forwarding to Number” is checked, enter the telephone number you would like to forward calls to when there is no answer on Line 1. This function is not available if “Enable Line 1 Basic Forwarding” is checked. Line 1 No Answer Forwarding Ring Count Enter the number of rings allowed before the call forwards to the number identified above. The default is six rings. 3-9 Enable Line 1 Forwarding on Busy Check this box to forward calls received while Line 1 is in use. Line 1 Busy Forwarding To Number If “Enable Line 1 Forwarding on Busy” is checked, enter the telephone number you would like calls forwarded to when Line 1 is in use. Enable Line 2 Basic Forwarding Check this box to enable basic call forwarding on Line 2. The default is unchecked. Line 2 Basic Forwarding to Number If “Enable Line 2 Basic Forwarding” is checked, enter the telephone number you would like to forward calls to. 3 Basic Configuration Table 3-11 Call Forwarding Tab Field or Button Description Enable Line 2 Forwarding on No Answer Check this box to forward calls received on Line 2 if there is no answer. This function is not available if “Enable Line 2 Basic Forwarding” is checked. Line 2 No Answer Forwarding to Number If “Line 2 No Answer Forwarding to Number” is checked, enter the telephone number you would like to forward calls to when there is no answer on Line 2. This function is not available if “Enable Line 2 Basic Forwarding” is checked. Line 2 No Answer Forwarding Ring Count Enter the number of rings allowed before the call forwards to the number identified above. The default is six rings. Enable Line 2 Forwarding on Busy Check this box to forward calls received while Line 2 is in use. Line 2 Busy Forwarding To Number If “Enable Line 2 Forwarding on Busy” is checked, enter the telephone number you would like calls forwarded to when Line 2 is in use. Be sure to click the Apply button once you have made changes. Voice Mail Tab The voice mail tab allows you to see the status of your voice mail. Please contact your service provider to activate the voice mail feature if it is not already active. The Voice Mail Tab contains the following: Table 3-12 Voice Mail Tab Field or Button Description Line 1 Server Based Voice Mail Status Shows the status of Line 1 voice mail as either enabled or disabled. Line 1 Number of New Voice Mails Shows the number of new, unheard voice mails on Line 1. Line 1 Number of Old Voice Mails Shows the number of previously heard voice mails on Line 1. Line 2 Server Based Voice Mail Status Shows the status of Line 2 voice mail as either enabled or disabled. Line 2 Number of New Voice Mails Shows the number of new, unheard voice mails on Line 2. Line 2 Number of Old Voice Mails Shows the number of previously heard voice mails on Line 2. Be sure to click the Apply button once you have made changes. 3-10 Basic Configuration Special Number Tab The Special Number tab provides a list of special dialing numbers for your VoIP Phone Service. The Special Number Tab contains the following: Table 3-13 Special Number Tab 68P09292A81-B JUN 2008 Field or Button Description Service Provider Contact Number Use this number to contact customer service for your service provider. Emergency Number Dial this number to reach local emergency services. Redial Dial this number to redial the last number called. Blind Call Transfer Dial this number to transfer a call directly to a third party. Consultation Call Transfer Dial this number to speak with the third party before you transfer the call to them. Call Hold Dial this number to place your current call on hold. Automatic Recall Activate Dial this number to call back the number of the last incoming call. Automatic Recall Deactivate Dial this number to automatically call back the last number dialed when that number becomes available. Call Forwarding Activate Dial this number to forward your calls to a different number. Call Forwarding Deactivate Dial this number to deactivate call forwarding. Call Forwarding Busy Activate Dial this number to forward calls to a different number when the line is busy. Call Forwarding Busy Deactivate Dial this number to de-activate calls from forwarding to a different number when the line is busy. Call Forwarding Busy Change Number Dial this number to change the phone number to which calls will be forwarded when the line is busy. Call Forwarding No Answer Activate Dial this number to forward calls to a different number when there is no answer on Line 1 or Line 2. Call Forwarding No Answer Deactivate Dial this number to de-activate calls from forwarding to a different number when there is no answer on Line 1 or Line 2. Call Forwarding No Answer Change Number Dial this number to change the phone number to which calls will be forwarded when there is no answer on Line 1 or Line 2. 3-11 3 Basic Configuration Table 3-13 Special Number Tab 3-12 Field or Button Description Automatic Callback Activate Dial this number to hear the most recent call you missed and to return the call. If the number is busy, you can hang up. When the number is available, your phone will ring. Pick up your phone and the call will be connected. Automatic Callback Deactivate Dial this number to de-activate automatic callback. Do Not Disturb Activate Dial this number to have calls automatically routed to voice mail. Do Not Disturb Deactivate Dial this number to cancel automatic call routing to voice mail. Calling Number Delivery Blocking Dial this number to block your number from appearing on the Caller ID of the people you call. Your calls may appear as “Private” or “Anonymous”. Line Blocking Deactivate Dial this number to unblock your telephone number from appearing on Caller ID. Call Waiting Toggle Dial this number to toggle between call waiting ON and call waiting OFF. Anonymous Call Rejection Activate Dial this number to have anonymous calls rejected. Anonymous Call Rejection Deactivate Dial this number to allow anonymous calls to go through. Advanced Configuration Chapter 4: Advanced Configuration The Advanced Configuration section describes the Port Forwarding, Local Address, and Control Panel menus. Port Forwarding Menu Port forwarding enables you to direct incoming traffic to specific LAN hosts (computers on your network) based on the protocol and port number. It is used to play Internet games or provide local services (such as web hosting) for a LAN group. The Port Forwarding menu provides the following tabs: • Basic • Forwarding Figure 4-1: Port Forwarding Table 4-1 Port Forwarding Menu Field or Button Description Enable UPnP IGD Enables the Universal Plug and Play (UPnP) Internet Gateway Device (IGD) profile to allow certain Windows applications to set up the port forwarding rule dynamically when NAT is enabled on this device. DMZ (DeMilitarized Zone) IP Address Enter the DMZ IP Address. Be sure to click the Apply button once you have made changes. 4-1 4 Advanced Configuration Forwarding Tab Click the ADD button to create additional Port Forwarding rules. The Forwarding tab contains the following selections: Table 4-2 Forwarding Tab Field or Button Description Select Select a box when you want to delete the specific row. Protocol Select TCP (Transmission Control Protocol) or UDP (User Datagram Protocol). WAN Port Start Enter the beginning port range for external network access. WAN Port End Enter the ending port range for external network access. LAN IP Address Enter the IP address to host the service. LAN Port Start Enter the beginning port range for internal network access. LAN Port End Enter the ending port range for internal network access. Enabled Check to enable specific port forwarding. Be sure to click the Apply button once you have made changes. Local Address Menu The Local Address menu allows you to configure your Local Area Network (LAN) connections. The Local Address menu provides the following tabs: • DHCP Server • Lease Status • Lease Reservation 4-2 Advanced Configuration Figure 4-2: Local Address Menu DHCP Server Tab The DHCP Server tab enables Dynamic Host Configuration Protocol (DHCP) server functionality on the LAN, allowing the router to dynamically assign lease IP addresses to clients that connect to it from the local network. The DHCP Server Tab contains the following selections: Table 4-3 DHCP Server Tab 4-3 Field or Button Description Enable DHCP Server If selected, the DHCP server on the gateway assigns IP addresses to the computers and other hosts on your network if they have DHCP enabled. By default, the gateway server is enabled. If there is another DHCP server running on your network (on another router), disable one of the DHCP servers. DHCP Server IP Address Enter the default port forwarding LAN Client IP Address. DHCP Starting IP Address Sets the first IP address assigned by the DHCP server, in dotted-decimal format. It must be greater than the IP address value of the gateway. For example, if the IP address of the gateway is 192.168.15.1 (default), the starting IP address must be 192.168.15.2 (or higher). 4 Advanced Configuration Table 4-3 DHCP Server Tab Field or Button Description DHCP Ending IP Address Sets the final IP address assigned by the DHCP server. If the DHCP server runs out of DHCP addresses, users cannot access network resources. If this happens, increase the Ending IP or reduce the Lease Time. DHCP Lease Time Sets the time, in seconds, that a network computer remains connected to the gateway using its current assigned IP address. At the end of this time, the DHCP server renews the lease or assigns the computer a new IP address. The default is 3600 seconds (one hour). The maximum is 999999 seconds (about 278 hours). Be sure to click the Apply button once you have made changes. Lease Status Tab The Lease Status tab in the Local Address menu displays the active DHCP leases since the last reboot. The Lease Status Tab contains the following selections: Table 4-4 Lease Status Tab Field or Button Description Client Host Name Displays the client host name. The Name field is limited to 20 characters (only 5 appear in display). MAC Address Media Access Control (MAC) address. IP Address Shows the IP Address for each active lease. Remaining Lease Duration Shows the amount of time, in seconds, remaining in the lease. Be sure to click the Apply button once you have made changes. Lease Reservation Tab This tab allows you to manage the lease reservation so that the same client receives the same IP address each time. The Lease Reservation Tab contains the following selections: 4-4 Advanced Configuration Table 4-5 Lease Reservation Tab Field or Button Description Select Select this box if you want to delete an established lease reservation. Be sure to click the Delete button once you have selected the exception to be deleted. Client Host Name Enter the client host name. The Name field is limited to 20 characters (only 5 appear in display) MAC Address Media Access Control (MAC) address. Enter the MAC address of the device. IP Address Enter the IP address that you want assigned to the MAC Address. Enabled Clicking this box enables the lease reservation. Be sure to click the Apply button once you have made changes. Control Panel The Control Panel sections allows you to view/update your software information. The Control menu provides the following tabs: • Software • Certificate • System • About 4-5 4 Advanced Configuration Figure 4-3: Control Panel Menu Software Tab The Software tab manages the software on your CPE device. It is also where you can upgrade device software. Use the BROWSE button to browse your computer for additional software packages. Once you have located the software package/update you would like to add to your device, click the Upgrade button. You should see the available software updates in the “Available Software Packages” table. If you cannot see the list, click the View button. Select the software you would like to install and click the Install button. If you would like to remove software, select the software package you would like to remove and click Uninstall. Certificate Tab The Certificate tab is where you manage the certificates that are stored on the device. Use the BROWSE button to locate the certificate file on your computer, and then click the IMPORT button. Use the REMOVE button to remove any selected certificate(s). System Tab This tab allows you to manage additional features of your CPE device 4-6 Advanced Configuration Table 4-6 System Tab Field or Button Description Language Used in User Interface Select the desired language for the user interface. The default language is English. Enable WiMAX Radio Interface Check this box to enable the WiMAX Radio Interface. Enable LED Check this box to enable the LEDs on the front of your CPE device. Auto Refresh Interval Enter, in seconds, the interval for status Auto Refresh. Valid range is 2 seconds 9999 seconds. The default value is 3 seconds. Rebootstrap EMS Check this box to reconnect the device with the EMS. Only perform this function under the supervision of a Customer Support Representative. About Tab The About Tab displays basic properties of your CPE device such as: Product Name, Model ID, Hardware Version, Serial Number, and the WiMAX MAC Address. 4-7 4 4-8 Advanced Configuration Configuring TCP/IP Chapter 5: Configuring TCP/IP This section contains two examples of configuring TCP/IP in a Windows environment. Most computers already have the TCP/IP configuration enabled. Use the following procedures to verify that the configuration is set up. Configure all client computers on your network for TCP/IP (the protocol that controls communication among computers). Two examples are provided in this document: • Configuring TCP/IP in Windows 2000 • Configuring TCP/IP in Windows XP NOTE Follow the instructions in your computer user manual for other Operating Systems. Configuring TCP/IP in Windows 2000 1. 2. On the Windows Desktop, click Start. Select Settings and then Control Panel from the pop-up menus to display the Control Panel window: Figure 5-1: Windows Control Panel 3. 5-1 Double-click the Network and Dial-up Connections icon to display the Network and Dial-up Connections window: 5 Configuring TCP/IP Figure 5-2: Network and Dial-up Connections In the steps that follow, a connection number like 1, 2, 3, etc., is a reference that is displayed on computers with multiple network interfaces. Computers with only one network interface may only see the label: Local Area Connection. 4. Click Local Area Connection number. The value of number varies from system to system. The Local Area Connection number Status window is displayed: Figure 5-3: Local Area Connection 5. 5-2 Click Properties. Information like the following window is displayed: Configuring TCP/IP Figure 5-4: Properties 6. If Internet Protocol (TCP/IP) is in the list of components, TCP/IP is installed. You can skip to Step 10. Figure 5-5: Select Network Connection Type If Internet Protocol (TCP/IP) is not in the list, click Install. The Select Network Component Type window is displayed: 7. Click Protocol on the Select Network Component Type window and click Add. The Select Network Protocol window is displayed: 5-3 5 Configuring TCP/IP Figure 5-6: Select Network Protocol NOTE You might have to use the scroll bar to locate the Internet Protocol (TCP/ IP) setting. 8. 9. 10. 11. Click Internet Protocol (TCP/IP). Click OK. The Local Area Connection number Properties window is re-displayed. Be sure the box next to Internet Protocol (TCP/IP) is checked. Click Properties. The Internet Protocol (TCP/IP) Properties window is displayed: Figure 5-7: Internet Protocol (TCP/IP) Properties 12. Be sure Obtain IP address automatically and Obtain DNS server address automatically are selected. 5-4 Configuring TCP/IP 13. 14. 15. 16. Click OK to accept the TCP/IP settings. Click Close to close the Local Area Connection number Properties window. Click OK. If prompted to restart the computer and click OK again. Configuring TCP/IP in Windows XP 1. On the Windows desktop, click Start to display the Start window: Figure 5-8: Windows XP Start Window 2. Click Control Panel to display the Control Panel window. The display varies, depending on your Windows XP view options. If the display is a Category view as shown in Figure 5-9, continue with Step 3. Otherwise, skip to Step 5. Figure 5-9: Control Panel 3. 5-5 Click Network and Internet Connections to display the Network and Internet Connections window: 5 Configuring TCP/IP Figure 5-10: Network and Internet Connections 4. 5. Click Network Connections. Skip to Step 6. If a classic view like Figure 5-11 is displayed, double-click Network Connections to display the LAN or High-speed Internet connections. Figure 5-11: Control Panel Classic View 6. 5-6 Right-click the Local Area Connection. If more than one connection is displayed, be sure to select the one for your network interface. Configuring TCP/IP Figure 5-12: Network Connections 7. Select Properties from the pop-up menu to display the Local Area Connection Properties window: Figure 5-13: Local Area Connection Properties 8. 9. 5-7 On the Local Area Connection Properties window, select Internet Protocol (TCP/ IP) if it is not selected. Click Properties to display the Internet Protocol (TCP/IP) Properties window. 5 Configuring TCP/IP Figure 5-14: Internet Protocol (TCP/IP) Properties 10. Be sure Obtain IP address automatically and Obtain DNS server address automatically are selected. 11. Click OK to close the TCP/IP Properties window. 5-8 Troubleshooting Chapter 6: Troubleshooting Power • • Check that the AC power adapter is properly plugged into the electrical outlet and into the Desktop CPE. Check that the electrical outlet is working. A Computer Cannot Log On to the CPE Check that the Ethernet cable is properly connected to the Desktop CPE unit and the computer. Cannot Connect to the Internet • • Check the Desktop CPE connection status from the Web Interface, refer to the Connection Status section to verify the connection status. If the Desktop CPE connection is down, and the gateway has not received an IP for 5 minutes to 10 minutes: - Re-Run the Setup Wizard. - If the Setup Wizard does not help, then reset the Desktop CPE using the reset button. Additional Troubleshooting Help Contact your service provider for additional help. 6-1 6 6-2 Troubleshooting Important Safety and Legal Information Chapter 7: Important Safety and Legal Information Your Motorola WiMAX Wireless Broadband Gateway is designed and tested to comply with a number of national and international standards and guidelines (listed below) regarding human exposure to RF electromagnetic energy. This Product complies with the following RF energy exposure standards and guidelines: • • • • • • • United States Federal Communications Commission, Code of Federal Regulations; 47CFR part 2 sub-part J American National Standards Institute (ANSI)/ Institute of Electrical and Electronic Engineers (IEEE) C95 1-2005 Institute of Electrical and Electronic Engineers (IEEE) C95.1-1999 Edition International Commission on Non-Ionizing Radiation Protection (ICNIRP) 1998 Ministry of Health (Canada) Safety Code 6. Limits of Human Exposure to Radio frequency Electromagnetic Fields in the Frequency Range from 3 kHz to 300 GHz, 1999 Australian Communications Authority Radiocommunications (Electromagnetic Radiation - Human Exposure) Standard, 2003 ANATEL ANNEX to Resolution No. 303 of July 2, 2002 “Regulation of Limitation of Exposure to Electrical, Magnetic, and Electromagnetic Fields in the Radio Frequency Range Between 9 kHz and 300 GHz” and “Attachment to Resolution #303 from July 2, 2002” RF Exposure Compliance and Guidelines Operating Instructions To comply with FCC RF energy exposure requirements, this Gateway desktop transmitter should be operated at a minimum separation distance of 20 cm from all persons. For additional information on exposure requirements or other training information, visit http://www.motorola.com/rfhealth FCC Regulatory Information The 2.5GHz WiMAX device (Model Name: CPEi25725) complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received; including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that interference will not occur in a particular installation, which can be determined by turning the equipment off and on, the user is encouraged to try to connect the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. 7-1 C Important Safety and Legal Information • • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This Gateway desktop transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. Industry Canada Statement 2.5GHz WiMAX device (Model Name: CPEi25725) complied with RSS-Gen and RSS193 of the Industry Canada Rules. Operation is subject to the following two conditions: • This device may not cause interference and • This device must accept any interference, including interference that may cause undesired operation of the device. This device has been designed to operate with an antenna having a maximum gain of 7 dBi. Antenna having a higher gain is strictly prohibited per regulations of Industry Canada. The required antenna impedance is 50 ohms. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (E.I.R.P) is not more than that permitted for successful communications. This Class B digital apparatus complies with Canadian ICES-003. Cet appariel numérique de la class B est conforme à la norme NMB-003 du Canada. Radiation Exposure Statemen IMPORTANT This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and you. 7-2 Important Safety and Legal Information Caring for the Environment The following information is provided to enable regulatory compliance with the European Union (EU) Directive 2002/96/EC Waste Electrical and Electronic Equipment (WEEE) when using Motorola Networks equipment in EU countries. 7-3 7 Important Safety and Legal Information Disposal of Motorola Equipment in EU Countries This product is compliant with the requirements of the European Union Restriction of Hazardous Substances (EU RoHS) directive. Please do not dispose of Motorola Networks equipment in landfill sites. In the EU, Motorola Networks in conjunction with a recycling partner will ensure that equipment is collected and recycled according to the requirements of EU environmental law. Disposal of Motorola Networks Equipment in Non-EU countries In non-EU countries, dispose of Motorola Networks equipment in accordance with national and regional regulations. CMM Disclosure The China Management Methods (CMM) Disclosure Table is intended only to communicate compliance with China requirements; it is not intended to communicate compliance with EU RoHS or any other environmental requirements. 7-4 Important Safety and Legal Information Copyrights and Trademarks Notice While reasonable efforts have been made to assure the accuracy of this document, Motorola, Inc. assumes no liability resulting from any inaccuracies or omissions in this document, or from use of the information obtained herein. The information in this document has been carefully checked and is believed to be entirely reliable. However, no responsibility is assumed for inaccuracies or omissions. Motorola, Inc. reserves the right to make changes to any products described herein and reserves the right to revise this document and to make changes from time to time in content hereof with no obligation to notify any person of revisions or changes. Motorola, Inc. does not assume any liability arising out of the application or use of any product, software, or circuit described herein; neither does it convey license under its patent rights or the rights of others. It is possible that this publication may contain references to, or information about Motorola products (machines and programs), programming, or services that are not announced in your country. Such references or information must not be construed to mean that Motorola intends to announce such Motorola products, programming, or services in your country. Copyrights This instruction manual, and the Motorola products described in this instruction manual may be, include or describe copyrighted Motorola material, such as computer programs stored in semiconductor memories or other media. Laws in the United States and other countries preserve for Motorola and its licensors certain exclusive rights for copyrighted material, including the exclusive right to copy, reproduce in any form, distribute and make derivative works of the copyrighted material. Accordingly, any copyrighted material of Motorola and its licensors contained herein or in the Motorola products described in this instruction manual may not be copied, reproduced, distributed, merged or modified in any manner without the express written permission of Motorola. Furthermore, the purchase of Motorola products shall not be deemed to grant either directly or by implication, estoppel, or otherwise, any license under the copyrights, patents or patent applications of Motorola, as arises by operation of law in the sale of a product. Usage and Disclosure Restrictions License Agreements The software described in this document is the property of Motorola, Inc. and its licensors. It is furnished by express license agreement only and may be used only in accordance with the terms of such an agreement. Copyrighted Materials Software and documentation are copyrighted materials. Making unauthorized copies is prohibited by law. No part of the software or documentation may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, without prior written permission of Motorola, Inc. 7-5 7 Important Safety and Legal Information High Risk Materials Components, units, or third-party products used in the product described herein are NOT fault-tolerant and are NOT designed, manufactured, or intended for use as online control equipment in the following hazardous environments requiring fail-safe controls: the operation of Nuclear Facilities, Aircraft Navigation or Aircraft Communication Systems, Air Traffic Control, Life Support, or Weapons Systems (High Risk Activities). Motorola and its supplier(s) specifically disclaim any expressed or implied warranty of fitness for such High Risk Activities. Trademarks MOTOROLA and the Stylized M Logo are registered in the US Patent & Trademark Office. All other product or service names are the property of their respective owners. © Motorola, Inc., 7-6 2009
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Copy, Extract, Print high-res XMP Toolkit : 3.1-701 Create Date : 2009:10:20 10:33:11+08:00 Creator Tool : Adobe Illustrator CS2 Modify Date : 2009:10:20 16:03+08:00 Metadata Date : 2009:10:20 16:03+08:00 Thumbnail Width : 184 Thumbnail Height : 256 Thumbnail Format : JPEG Thumbnail Image : (Binary data 10555 bytes, use -b option to extract) Producer : Acrobat Distiller 8.0.0 (Windows) Format : application/pdf Creator : eden Title : CPEi25725UM.pdf Instance ID : uuid:48687187-233a-407b-b467-823f7466c204 Document ID : uuid:79eda710-b6ed-4f49-bb31-919fe07ac045 Page Count : 48 Author : edenEXIF Metadata provided by EXIF.tools