Nokia Solutions and Networks T6DY1 SC4812T-MC 1X/1X-DO @ 1.9GHz User Manual 1
Nokia Solutions and Networks SC4812T-MC 1X/1X-DO @ 1.9GHz 1
Contents
- 1. Manual A
- 2. Manual B
Manual A
The manual included is presently being edited and is a preliminary version representative of the SC4812T-MC 1X/1X-EVDO @ 1.9 GHz CDMA BTS Optimization Manual Technical Information 1X SC4812T–MC BTS OPTIMIZATION/ATP SOFTWARE RELEASE 2.16.4.X 800 MHZ & 1.9 GHZ CDMA2000 1X DRAFT ENGLISH 5/21/04 68P09260A64–B SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Notice While reasonable efforts have been made to assure the accuracy of this document, Motorola, Inc. assumes no liability resulting from any inaccuracies or omissions in this document, or from use of the information obtained herein. The information in this document has been carefully checked and is believed to be entirely reliable. However, no responsibility is assumed for inaccuracies or omissions. Motorola, Inc. reserves the right to make changes to any products described herein and reserves the right to revise this document and to make changes from time to time in content hereof with no obligation to notify any person of revisions or changes. Motorola, Inc. does not assume any liability arising out of the application or use of any product, software, or circuit described herein; neither does it convey license under its patent rights or the rights of others. It is possible that this publication may contain references to, or information about Motorola products (machines and programs), programming, or services that are not announced in your country. Such references or information must not be construed to mean that Motorola intends to announce such Motorola products, programming, or services in your country. Copyrights This instruction manual, and the Motorola products described in this instruction manual may be, include or describe copyrighted Motorola material, such as computer programs stored in semiconductor memories or other media. Laws in the United States and other countries preserve for Motorola and its licensors certain exclusive rights for copyrighted material, including the exclusive right to copy, reproduce in any form, distribute and make derivative works of the copyrighted material. Accordingly, any copyrighted material of Motorola and its licensors contained herein or in the Motorola products described in this instruction manual may not be copied, reproduced, distributed, merged or modified in any manner without the express written permission of Motorola. Furthermore, the purchase of Motorola products shall not be deemed to grant either directly or by implication, estoppel, or otherwise, any license under the copyrights, patents or patent applications of Motorola, as arises by operation of law in the sale of a product. Usage and Disclosure Restrictions License Agreement The software described in this document is the property of Motorola, Inc and its licensors. It is furnished by express license agreement only and may be used only in accordance with the terms of such an agreement. Copyrighted Materials Software and documentation are copyrighted materials. Making unauthorized copies is prohibited by law. No part of the software or documentation may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, without prior written permission of Motorola, Inc. High Risk Activities Components, units, or third–party products used in the product described herein are NOT fault–tolerant and are NOT designed, manufactured, or intended for use as on–line control equipment in the following hazardous environments requiring fail–safe controls: the operation of Nuclear Facilities, Aircraft Navigation or Aircraft Communication Systems, Air Traffic Control, Life Support, or Weapons Systems (“High Risk Activities”). Motorola and its supplier(s) specifically disclaim any expressed or implied warranty of fitness for such High Risk Activities. Trademarks MOTOROLA and the Stylized M Logo are registered in the US Patent & Trademark Office. All other product or service names are the property of their respective owners. © Copyright 2004 Motorola, Inc. Javat Technology and/or J2MEt: Java and all other Java–based marks are trademarks or registered trademarks of Sun Microsystems, Inc. in the U.S. and other countries. UNIXR: UNIX is a registered trademark of The Open Group in the United States and other countries. REV091302 DRAFT Table of Contents 1X SC4812T–MC BTS Optimization/ATP Software Release 2.16.4.x 5/21/04 1X SC4812T–MC BTS Optimization/ATP DRAFT List of Figures 1X SC4812T–MC BTS Optimization/ATP Software Release 2.16.4.x ii 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 List of Tables 1X SC4812T–MC BTS Optimization/ATP Software Release 2.16.4.x 5/21/04 1X SC4812T–MC BTS Optimization/ATP DRAFT iii Foreword Scope of manual This manual is intended for use by cellular telephone system craftspersons in the day-to-day operation of Motorola cellular system equipment and ancillary devices. This manual is not intended to replace the system and equipment training offered by Motorola, although it can be used to supplement or enhance the knowledge gained through such training. Obtaining manuals To view, download, or order manuals (original or revised), visit the Motorola Lifecycles Customer web page at https://mynetworksupport.motorola.com/, or contact your Motorola account representative. If Motorola changes the content of a manual after the original printing date, Motorola publishes a new version with the same part number but a different revision character. Text conventions The following special paragraphs are used in this manual to point out information that must be read. This information may be set-off from the surrounding text, but is always preceded by a bold title in capital letters. The four categories of these special paragraphs are: NOTE Presents additional, helpful, non-critical information that you can use. IMPORTANT Presents information to help you avoid an undesirable situation or provides additional information to help you understand a topic or concept. CAUTION Presents information to identify a situation in which damage to software, stored data, or equipment could occur, thus avoiding the damage. WARNING Presents information to warn you of a potentially hazardous situation in which there is a possibility of personal injury. iv 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 Foreword – continued The following typographical conventions are used for the presentation of software information: S In text, sans serif BOLDFACE CAPITAL characters (a type style without angular strokes: for example, SERIF versus SANS SERIF) are used to name a command. S In text, typewriter style characters represent prompts and the system output as displayed on an operator terminal or printer. S In command definitions, sans serif boldface characters represent those parts of the command string that must be entered exactly as shown and typewriter style characters represent command output responses as displayed on an operator terminal or printer. S In the command format of the command definition, typewriter style characters represent the command parameters. Reporting manual errors To report a documentation error, call the CNRC (Customer Network Resolution Center) and provide the following information to enable CNRC to open an SR (Service Request): – the document type – the manual title, part number, and revision character – the page number(s) with the error – a detailed description of the error and if possible the proposed solution Motorola appreciates feedback from the users of our manuals. Contact us Send questions and comments regarding user documentation to the email address below: cdma.documentation@motorola.com Motorola appreciates feedback from the users of our information. Manual banner definitions A banner (oversized text on the bottom of the page, for example, PRELIMINARY) indicates that some information contained in the manual is not yet approved for general customer use. 24-hour support service If you have problems regarding the operation of your equipment, please contact the Customer Network Resolution Center (CNRC) for immediate assistance. The 24 hour telephone numbers are: North America Europe, Middle East, Africa Asia Pacific Japan & Korea . . . . . . . . . . . +1–800–433–5202 +44– (0) 1793–565444 +86–10–88417733 +81–3–5463–3550 For further CNRC contact information, contact your Motorola account representative. 5/21/04 1X SC4812T–MC BTS Optimization/ATP DRAFT General Safety Remember! . . . Safety depends on you!! The following general safety precautions must be observed during all phases of operation, service, and repair of the equipment described in this manual. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the equipment. Motorola, Inc. assumes no liability for the customer’s failure to comply with these requirements. The safety precautions listed below represent warnings of certain dangers of which we are aware. You, as the user of this product, should follow these warnings and all other safety precautions necessary for the safe operation of the equipment in your operating environment. Ground the instrument To minimize shock hazard, the equipment chassis and enclosure must be connected to an electrical ground. If the equipment is supplied with a three-conductor ac power cable, the power cable must be either plugged into an approved three-contact electrical outlet or used with a three-contact to two-contact adapter. The three-contact to two-contact adapter must have the grounding wire (green) firmly connected to an electrical ground (safety ground) at the power outlet. The power jack and mating plug of the power cable must meet International Electrotechnical Commission (IEC) safety standards. NOTE Refer to Grounding Guideline for Cellular Radio Installations – 68P81150E62. Do not operate in an explosive atmosphere Do not operate the equipment in the presence of flammable gases or fumes. Operation of any electrical equipment in such an environment constitutes a definite safety hazard. Keep away from live circuits Operating personnel must: S not remove equipment covers. Only Factory Authorized Service Personnel or other qualified maintenance personnel may remove equipment covers for internal subassembly, or component replacement, or any internal adjustment. S not replace components with power cable connected. Under certain conditions, dangerous voltages may exist even with the power cable removed. S always disconnect power and discharge circuits before touching them. vi 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 General Safety – continued Do not service or adjust alone Do not attempt internal service or adjustment, unless another person, capable of rendering first aid and resuscitation, is present. Use caution when exposing or handling the CRT Breakage of the Cathode–Ray Tube (CRT) causes a high-velocity scattering of glass fragments (implosion). To prevent CRT implosion, avoid rough handling or jarring of the equipment. The CRT should be handled only by qualified maintenance personnel, using approved safety mask and gloves. Do not substitute parts or modify equipment Because of the danger of introducing additional hazards, do not install substitute parts or perform any unauthorized modification of equipment. Contact Motorola Warranty and Repair for service and repair to ensure that safety features are maintained. Dangerous procedure warnings Warnings, such as the example below, precede potentially dangerous procedures throughout this manual. Instructions contained in the warnings must be followed. You should also employ all other safety precautions that you deem necessary for the operation of the equipment in your operating environment. WARNING Dangerous voltages, capable of causing death, are present in this equipment. Use extreme caution when handling, testing, and adjusting . 5/21/04 1X SC4812T–MC BTS Optimization/ATP DRAFT vii Revision History Manual Number 68P09260A64–B Manual Title 1X SC4812T–MC BTS Optimization/ATP Software Release 2.16.4.x Version Information The following table lists the manual version, date of version, and remarks on the version. Version Level Date of Issue MAY 2004 viii Remarks Upissue to include 1.9 GHz information 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 1 Chapter 1: Introduction Table of Contents 5/21/04 Guide Book . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–2 Document Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . What Is In This Guide? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–2 1–2 Book Catalogs and Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Book Directory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Special Catalogs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–3 1–3 1–5 Physical Page Layouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A/A4 Page and Margin Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A/A4 Page Text Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A/A4 Page Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–6 1–6 1–7 1–9 Frame and Table Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Frames With Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flow Charts and Block Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Line Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Table Types In This Template . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Item/Description Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Step Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Step/Check Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–10 1–10 1–10 1–11 1–12 1–12 1–13 1–14 Component Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–15 Conclusions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–16 Map Title Goes Here lkjsfdg Sfdkgj Msfd N lkas K lkjsdfl kB lkj fgcb . . . . . . Block Label Goes Here . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Block Label Goes Here . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Block Label Goes Here . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Block Label Goes Here . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–17 1–17 1–17 1–18 1–19 Map Title Goes Here . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–22 1X SC4812T–MC BTS Optimization/ATP DRAFT 1 Table of Contents – continued Notes 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 Read Me First: SCE4812T–MC to SCE4812T Comparison Physical Differences This Read-me-first document describes a summary of changes between the existing SC4812T 800MHz BTS and the SC4812T-MC (Multicarrier) BTS. The SC4812T-MC is based on the existing SC 4812T platform and employs similar hardware and architecture. The differences between these products are briefly described and illustrated below. This section is not intended to replace the SC4812T-MC manual set. This information applies generally to both 800 MHz +27V and –48V frames, although only +27V illustrations are shown. Multicarrier provides the capability for all PAs in all quadrants to provide trunked power across all sector/carriers. This differs from the previous architecture in which PA modules within a quadrant provided trunked power to only one carrier. Furthermore, in SC4812T-MC, adjacent channels can be combined onto one antenna versus being transmitted on separate antennas in SC4812T. An overview of the BTS differences is illustrated in the following table and in illustrations on the following pages (Figure 1-1 thru Figure 1-4). Description SC4812T ti-CDMA-WP-00098-v01-ildoc-ftw 5/21/04 Description 3x3 DC Power Input (see Figure 1-1) 2x2 DC Power Input (see Figure 1-1) I/O Plate supporting 3x3 DC Power Input (see Figure 1-2) I/O Plate supporting 2x2 DC Power Input (see Figure 1-2) C–CCP Fan Tray C–CCP Speed– Controlled Fan Tray C-CCP Cage: S CIO (3- or 6-Sector) S BBX-1X S Switch C-CCP Cage: S MCIO (3- or 6-Sector) S High Power BBX-1X S High Power Switch PA Shelves: S SC 4812T LPA S 4x4 TX Backplane S PA Location and Mapping (see Figure 1-3) S Shelf Qty: 1 for up to 2 carriers; 2 for 3 or more carriers. PA Shelves: S SC 4812T CLPA S Multicarrier module S (Switched) Parallel Linear amplifier Combiner S Enhanced Trunking Module S LPA/PLC Filler Panel S PA Location and Mapping (see Figure 1-3) S Shelf Qty: 2 for all configurations 2:1 or 4:1 Combiners or Dual Bandpass TX Filters TX Filters and/or TX Output Terminator PA Breaker Mapping (see Figure 1-4) PA Breaker Mapping (see Figure 1-4) 1X SC4812T–MC BTS Optimization/ATP DRAFT SC4812T-MC ti-CDMA-WP-00196-v01-ildoc-ftw 1-1 Read Me First: SCE4812T–MC to SCE4812T Comparison – continued Figure 1-1: DC Power Input Connector Comparison SC 4812T SC 4812T–MC CABLE LUG COVER (1509789V01) DC CABLE (–) GROMMET (0509591Y02) (+) DC CABLE DC CONTACT DC CONTACT DC Connector Housing M10 NUT (0210971A09) M10 LOCK WASHER (0410985A02) (–) Input Connector/ DC Filter M10 FLAT WASHER (0410983B28) CRIMP LUG POWER INPUT STUD (+) FEED COVER (DO NOT REMOVE) ENCLOSURE BASE ti-CDMA-WP-00024-v01-ildoc-ftw ti-CDMA-WP-00074-v01-ildoc-ftw Figure 1-2: I/O Plate Comparison SC 4812T SC 4812T–MC RECEIVE ANTENNA CONNECTORS SPAN I/O SITE I/O SPAN I/O REMOTE GPS DISTRIBUTION (RGD) MODULE – USED ONLY IF EXPANSION FRAME(S) INSTALLED ÄÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄÄ PACKET BACKHAUL PORTS SPAN I/O LOW FREQUENCY RECEIVER / HSO RF EXPANSION PORT (TO ANOTHER BTS) ALARM CONNECTORS TRANSMIT ANTENNA CONNECTORS POWER INPUT ESM SPAN I/O SITE I/O RECEIVE ANTENNA CONNECTORS LAN CONNECTIONS ÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄ ETHERNET ROUTER (IF USED; OTHERWISE, FILLER PLATE) ti-CDMA-WP-00101-v01-ildoc-ftw EXP IN FILLER PLATE GPS IN HSO/LFR FILLER PLATE INPUT CONNECTOR/ DC FILTER 3 to 6 TX ANTENNA CONNECTORS (depending on configuration) 2 to 3 TX ANTENNA FILLER PLATES (depending on configuration) RF EXPANSION PORT TO ANOTHER BTS (USED ONLY IF EXPANSION FRAME INSTALLED; OTHERWISE, FILLER PLATE INSTALLED) ti-CDMA-WP-00188-v01-ildoc-ftw 1-2 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 Read Me First: SCE4812T–MC to SCE4812T Comparison – continued Figure 1-3: PA Location Comparison SC 4812T SC 4812T–MC Sector Numbering 3 Sector (6 Sector) Sector Numbering 3 Sector (6 Sector) 2 to 1 Combiner 3 Sector or 6 Sector LPA 2B LPA 1B 3 Sector and 6 Sector C2, S1–3 (C2, S1–3) LPA 2C LPA 1C LPA 2D LPA 1D CLPA 1A CLPA 2A CLPA 3A CLPA 2C LPA 4B LPA 3B C4, S1–3 (C2, S4–6) LPA 4C LPA 3C MCM CLPA 3C S6 CLPA 4C FW00297 REF. S4 50 50 50 2B 50 4B 50 2C 50 4C 50 2D 3D 4D 1A 3A 1B 3B 1C 3C 1D 2A 30 2B 4C 30 4D 50 50 50 50 CIRCUIT BREAKER PANEL 50 2C 30 2D 4A 30 4B 4A 50 1C 30 1D 2A 50 1A 30 1B 3C 30 3D CLPA 3B CLPA 4B CLPA 1D CLPA 2D CLPA 3D CLPA 4D SC4812T–MC SC 4812T 3A 30 3B CLPA 2B NOTES: ti-CDMA-WP-00197-v01-ildoc-ftw MCM CAN BE EITHER 3.3 OR 4X4 MCM2 IS REQUIRED ONLY IN A 6–SECTOR CONFIGURATION LOWER RIGHT QUADRANT WILL ONLY HAVE CLPAS IN IT IN A 4.4 CONFIGURATION Figure 1-4: PA Breaker Mapping Comparison CLPA 1B S5 LPA 4D LPA 3D S3 S1 CLPA 1C LPA 4A LPA 3A MCM S2 CLPA 4A C3, S1–3 (C1, S4–6) Carrier Numbering 3 Sector (6 Sector) LPA 2A LPA 1A C1, S1–3 (C1, S1–3) Carrier Numbering 3 Sector (6 Sector) ti-CDMA-WP-00224-v01-ildoc-ftw FW00380 REF. CAUTION Each breaker controls a pair of PAs. In an SC4812T–MC, opening (pulling) a PA breaker while the BTS is operating will degrade the TX Output power of ALL sector–carriers, not just a specific carrier as in an SC4812T. 5/21/04 1X SC4812T–MC BTS Optimization/ATP DRAFT 1-3 Read Me First SCE4812T–MC to SCE4812T Optimization/ATP General Test Procedural Changes for SC 4812T-MC NOTE The GENERAL information herein summarizes procedural changes introduced with the SC 4812T–MC BTS. Detailed procedures are provided in the Optimization and ATP sections. NOTE 1. During the execution of any TX tests or calibration procedures, ALL Power Amplifiers (PA) must be in service (INS). 2. When logging into a BTS with a system release earlier than 2.16.4.x, be sure to set BTS type to MultiCarrier in the dialog box which will appear when logging into the BTS. Transmit (TX) Bay Level Offset (BLO) Specifications – SC4812T–MC TX BLO specifications for different BTS sector configurations are as follows: S 800 MHz Three–sector BTS: – Single–sided BLO: >35dB – Double–sided BLO: 40dB +/– 5dB S 800 MHz Six–sector BTS – Single–sided BLO: >38dB – Double–sided BLO: 43dB +/– 5dB S 1.9 GHz Three–sector BTS: – Single–sided BLO: >30dB – Double–sided BLO: 35dB +/– 5dB S 1.9 GHz Six–sector BTS – Single–sided BLO: >33dB – Double–sided BLO: 38dB +/– 5dB Verifying Pilot Power Setting with a Wide Band RF Power Meter The SC4812T–MC requires all equipped PAs be enabled during TX test. With a “tuned” RF power meter, such as the Agilent VSA E4406A, all sectors–carriers can be enabled simultaneously and each sector–carrier power level setting can be measured. The following work–around procedures are suggested when using a wide band RF power meter and the BTS is under OMC–R control. 1-4 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 Read Me First SCE4812T–MC to SCE4812T Optimization/ATP – continued NOTE This workaround is only required before system release 2.16.4.x. After release 2.16.4.x, any one BBX keyed will enable all the CLPA modules. 1–carrier configuration (requires 3 measurements) – The 1-carrier procedure is identical to the current SC4812T, which is to enable all three sector BBXs, then measure with each sector with the RF power meter. 2–carrier configuration (requires 6 measurements) – The procedure below allows taking measurements with both carriers enabled and more than one carrier on same sector. Sector Carrier 1 BBX-1 BBX-2 Carrier 2 Sector BBX-9 Carrier 1 Carrier 2 BBX-7 BBX-8 BBX-3 Procedure: 1. Enable BBX-1 (C1–S1), BBX-2 (C1–S2), and 4. Enable BBX-3 (C1–S3), BBX-7 (C2–S1), and BBX-9 (C2–S3). BBX-8 (C2–S2). 2. Measure TX power from each of all 3 sectors. 5. Measure TX power from each of all 3 sectors. 3. Disable BBX-1, BBX-2, and BBX-9. 6. Disable BBX-3, BBX-7, and BBX-8. 3–carrier configuration (requires 9 measurements) – The procedure below allows taking measurements with all 3 carriers enabled and more than one carrier on same sector. Sector Carrier BBX-1 Carrier Carrier BBX-8 BBX-6 1. Enable BBX-1 (C1–S1), BBX8 (C2–S2), and BBX6 (C3–S3) 2. Measure TX power from each of all 3 sectors 3. Disable BBX1, BBX8, and BBX6 5/21/04 Sector Carrier Carrier Carrier BBX-4 BBX-2 BBX-9 Procedure: 4. Enable BBX-2 (C1–S2), BBX-9 (C2–S3), and BBX-4 (C3–S1) 5. Measure TX power from each of all 3 sectors 6. Disable BBX-2, BBX-9, and BBX-4 1X SC4812T–MC BTS Optimization/ATP DRAFT Sector Carrier Carrier BBX-7 Carrier BBX-5 BBX-3 7. Enable BBX-3 (C1–S3), BBX-7 (C2–S1), and BBX-5 (C3–S2) 8. Measure TX power from each of all 3 sectors 9. Disable BBX-3, BBX-7, and BBX-5 1-5 Read Me First SCE4812T–MC to SCE4812T Optimization/ATP – continued 4–carrier configuration (requires 12 measurements) – Use this procedure to take measurements with all 4 carriers enabled. The sector with 2 carriers active will not be measured. Sector Carrier 1 BBX-1 Carrier 2 Carrier 3 Carrier 4 BBX-6 BBX-12 BBX-8 Sector Carrier 1 Carrier 2 Carrier 3 BBX-4 Carrier 4 BBX-10 BBX-2 BBX-9 Procedure: 1. Enable BBX-1, BBX-8, BBX-6, and BBX-12. 4. Enable BBX-2, BBX-9, BBX-4, and BBX-10. 2. Measure TX power from at sector 1 carrier 1 5. Measure TX power of C1-S2 and C2-S3. (C1-S1) and sector 2 carrier 2 (C2-S2). 6. Disable BBX-2, BBX-9, BBX-4, and BBX-10. 3. Disable BBX-1, BBX-8, BBX-6, and BBX-12. Sector Carrier 1 Carrier 2 BBX-7 Carrier 3 Carrier 4 BBX-5 BBX-11 BBX-3 Sector Carrier 1 BBX-1 Carrier 2 BBX-7 Carrier 3 Carrier 4 BBX-5 BBX-12 Procedure: 7. Enable BBX-3, BBX-7, BBX-5, and BBX-11. 10.Enable BBX-1, BBX-7, BBX-5, and BBX-12. 8. Measure TX power of C1-S3 and C2-S1. 11. Measure TX power of C3-S2 and C4-S3. 9. Disable BBX-3, BBX-7, BBX-5, and BBX-11. 12.Disable BBX-1, BBX-7, BBX-5, and BBX-12. Sector Carrier 1 BBX-2 Carrier 2 Carrier 3 Carrier 4 Sector BBX-10 BBX-8 BBX-6 Carrier 1 Carrier 2 Carrier 3 Carrier 4 BBX-4 BBX-11 BBX-3 BBX-9 Procedure: 13.Enable BBX-2, BBX-8, BBX-6, and BBX-10. 16.Enable BBX-3, BBX-9, BBX-4, and BBX-11. 14.Measure TX power of C3-S3 and C4-S1. 17.Measure TX power C3-S1 and C4-S2. 15.Disable BBX-2, BBX-8, BBX-6, and BBX-10. 18.Disable BBX-3, BBX-9, BBX-4, and BBX-11. 1-6 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 Read Me First SCE4812T–MC to SCE4812T Optimization/ATP – continued 2–carrier, 6–sector configuration (requires 12 measurements) – Use this procedure to take measurements with both carriers enabled. Sector Carrier 1 BBX-1 BBX-2 Carrier 2 Sector BBX-9 BBX-4 BBX1–11 BBX1–12 1. Enable the following BBXs: – BBX-1 (C1–S1) – BBX-2 (C1–S2) – BBX-4 (C1-S4) – BBX-9 (C2–S3) – BBX-11 (C2-S5) – BBX-12 (C2-S6) 2. Measure TX power from each of all 6 sectors. 3. Disable BBXs. 5/21/04 Carrier 1 Carrier 2 BBX-7 BBX-8 BBX-3 BBX-10 BBX-5 BBX-6 Procedure: 4. Enable the following BBXs: – BBX-3 (C1–S3) – BBX-5 (C1-S5) – BBX-6 (C1-S6) – BBX-7 (C2–S1) – BBX-8 (C2–S2) – BBX-10 (C2-S4) 5. Measure TX power from each of all 6 sectors. 6. Disable BBXs. 1X SC4812T–MC BTS Optimization/ATP DRAFT 1-7 1 Scope, Assumptions, and Audience CAUTION 1. Procedures in this manual apply to an SC4812T–MC BTS operating with Dynamic Multi–Carrier PA Control under Motorola Software Release 2.16.4.1 and later. These procedures will not work for an SC4812T–MC BTS operating with Motorola Software Release 2.16.4.0 and earlier. 2. Procedures in this manual require the use of Local Maintenance Facility (LMF) application software version 2.16.4.0.09 or later. Scope This publication provides information pertaining to the optimization and acceptance tests of the SC™4812T–Multi–Carrier Base Transceiver Subsystem (1X SC4812T–MC BTS). The following models equipped with trunked Power Amplifiers (PA) and their associated internal and external interfaces are covered: S 800 MHz models ST1407/ST1408 S 1.9 GHz models ST1426/ST1428 Circuit and Packet BTS Support Information in this publication supports optimization and calibration of the following types of BTS sites operating with Motorola Software Release 2.16.4.1 and later: S 1X circuit BTS S 1X packet BTS The cdma2000 1X (1X) packet BTS has a packet backhaul network interface provided through BTS routers operating with a Third–generation Group Line Interface (GLI3) card that can support voice (IS-95A/B, 1X) and data (IS-95B, 1X). This BTS equipment may be configured with all 1X cards (BBX–1X and MCC–1X) or a mix of 1X cards and non–1X cards (BBX2 and MCC8E/24E). This configuration is compliant with all applicable 1X specifications. It provides the forward link and reverse link RF functions to support Second Generation (2G) features and Third Generation (3G) 1X features; that is, high capacity voice and high bit–rate data. The 1X circuit BTS is capable of using a split or mixed backhaul (circuit/packet pipe) network interface that can handle circuit–based voice (IS-95A/B, 1X) and data (IS-95B) as well as “packetized” data (1X). 1-8 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 Scope, Assumptions, and Audience – continued Assumptions This document assumes that the BTS frames and cabling have been installed according to the following manuals: S SC Product Family Frame Mounting Guide, which covers the physical “bolt down” of all SC series equipment frames S 1X SC 4812T-MC BTS Hardware Installation , which covers BTS specific cabling configurations for Packet Backhaul and the addition of carriers to the BTS Audience Motorola Technical Information Products and Services (TIPS) has attempted to incorporate into this document the many customer suggestions and inputs received since the inception of the SC product line. At the same time, TIPS has tried to ensure that the scope of the document targets both the novice and expert site technician and engineer with the information required to successfully perform the task at hand. If, in some areas, the manual seems to cover the subject in too much or not enough detail, please keep this in mind. Intended Reader Profile The information in this manual set is intended for use by the cellular communications craftsperson(s) in the initial installation and configuration, as well as the day-to-day operation and maintenance of a BTS. The user of this information has a general understanding of telephony, as used in the operation of the Public Switched Telephone Network (PSTN), and is familiar with these concepts as they are applied in the cellular and maintenance mobile/portable radiotelephone environment. The user also needs a working knowledge of MSr Windows® 98$or Windows 2000™. 5/21/04 1X SC4812T–MC BTS Optimization/ATP DRAFT 1-9 1 Content Summary Publication Composition This publication covers the following areas. S Introduction: preliminary background information (such as component and subassembly locations and frame layouts) to be considered by the Cellular Field Engineer (CFE) before optimization or tests are performed. S Preliminary Operations: jumper configuration of BTS sub–assemblies, pre–power up tests, initial power application and power–up tests for the BTS equipment frame after installation, and download of all BTS processor boards and PAs. S Optimization/Calibration: downloading all BTS processor boards, test equipment set–up and calibration, PA verification, radio frequency (RF) path verification, Bay Level Offset (BLO) calibration, Cellular Radio Monitoring System (CRMS), and Radio Frequency Diagnostic System (RFDS) functions and calibration. S Acceptance Test Procedures (ATP): automated ATP scripts executed by the LMF and used to verify all major transmit (TX) and receive (RX) performance characteristics on all BTS equipment. Includes generating an ATP report. S Prepare to Leave the Site: site turnover process after ATP is completed. S Basic Troubleshooting: procedures to perform when an ATP fails, as well as when incorrect results are obtained during logon, test equipment operation, calibration, and Global Positioning System (GPS) operation. These tests are typically used to isolate faults down to the module level. Also provided is additional information necessary to better understand equipment operation. S Appendices that contain pertinent data sheets that are filled out manually by the CFE at the site, Pseudorandom Noise (PN) Offset information, an optimization/ATP matrix , output power data tables, CDMA operating frequency programming information, manual test setup information, procedures for verifying that the Voltage Standing Wave Ratio (VSWR) of all antennas and associated feed lines fall within acceptable limits, and procedures for downloading ROM and RAM code. 1-10 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 Purpose of Optimization Why Optimize? Proper optimization and calibration ensures that: S Accurate downlink RF power levels are transmitted from the site. S Accurate uplink signal strength determinations are made by the site. What Is Optimization? Optimization compensates for the site-specific cabling and normal equipment variations. Site optimization guarantees that the combined losses of the cables and the gain/loss characteristics and built-in tolerances of each BTS frame do not accumulate and cause improper site operation. What Happens During Optimization? Overview – During optimization, the accumulated path loss or gain is first determined for each RF transmit path in the BTS. These transmit path loss or gain values are then stored in a database along with RF receive path default values. RF path defintions – For definitions of the BTS transmit (TX) and receive (RX) paths, see “What is Bay Level Offset Calibration?” in the Bay Level Offset Calibration section of Chapter 3. NOTE In this publication, all models of the Broad Band Transceiver (BBX) board usable in this BTS, are generically identified as BBX, unless otherwise specified. Also, all models of the Multi–Channel CDMA (MCC) cards usable in this BTS, are generically identified as MCC, unless otherwise specified. RF paths and transceiver optimization – Twelve of the BBX boards in each Combined–CDMA Channel Processor (C–CCP) shelf are optimized to specific RX and TX antenna connectors. The last BBX board provides redundancy for BBX boards 1 through 12, and is optimized to all antenna connectors. A single optimization value is generated for each complete path. This eliminates the accumulation of error that would occur from individually measuring and summing the gain and loss of each element in the path. Using RF path gain/loss values – BTS equipment factors in the derived optimization values internally to adjust transceiver power levels, leaving only site–specific antenna feedline loss and antenna gain characteristics to be factored in by the CFE when determining required site Effective Radiated Power (ERP) output power levels. 5/21/04 1X SC4812T–MC BTS Optimization/ATP DRAFT 1-11 1 When to Optimize New Installations The following operations and optimization/test actions should be accomplished for a new BTS or frame installation: 1. After the initial site installation, the BTS must be prepared for operation. This preparation includes verifying hardware installation, initial power–up, downloading of operating code, verifying GPS operation, and verifying transmit and receive paths. 2. Next, the optimization is performed. Optimization includes performance verification and calibration of all transmit and receive RF paths, and download of accumulated calibration data. 3. A calibration audit of all RF transmit paths may be performed any time after optimization to verify BTS calibration. 4. After optimization, a series of manual pre–Acceptance Test Procedure (ATP) verification tests are performed to verify alarm/redundancy performance. 5. After manual pre–ATP verification tests, an ATP is performed to verify BTS performance. An ATP is also required to demonstrate regulation compliance before the site can be placed in service. Site Expansion Optimization is also required after expansion of a site with additional BTS frames. Periodic Optimization Periodic optimization of a site may also be required, depending on the requirements of the overall system. Repaired Sites Refer to Appendix C for a detailed FRU Optimization/ATP Test Matrix outlining the minimum tests that must be performed any time a BTS RF subassembly or cable associated with an RF path is replaced. 1-12 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 Test Equipment Selection, Calibration, and General Operation Requirememnts Policy General Requirements – To ensure consistent, reliable, and repeatable optimization test results, test equipment and software meeting the following technical criteria should be used to optimize the BTS equipment. Test equipment substitution – Test equipment can, of course, be substituted with other test equipment models but those models must meet the same technical specifications. All test equipment models selected for use in BTS calibration and acceptance testing must be supported by the LMF.. Measurement variances and test equipment substitution – It is the responsibility of the customer to account for any measurement variances and/or additional losses/inaccuracies that can be introduced as a result of test equipment model substitutions. Before beginning optimization or troubleshooting, make sure that the test equipment needed is on–hand and operating properly. Test Equipment Calibration Optimum system performance and capacity depend on regular equipment service and calibration prior to BTS optimization. Follow the original equipment manufacturer (OEM) recommended maintenance and calibration schedules closely. Test Cable Calibration On–site cable calibration – Test cables can make critical differences in optimization accuracy. It is recommended that cable calibration be run at every BTS with the complete test equipment set. This method compensates for test cable insertion loss within the test equipment set itself. No other allowance for test cable insertion loss needs to be made during the performance of BTS calibration or acceptance tests. In–shop cable characterization – Another method to account for cable loss is by entering it into the LMF during the optimization procedure. This method requires accurate test cable characterization using shop test equipment. Characterized cables should be tagged with the characterization information, and the measured losses entered into the LMF before field optimization. Equipment Warm–up After arriving at the a site, the test equipment should be plugged in and turned on to allow warm up and stabilization to occur for as long as possible. The following pieces of test equipment must be warmed–up for a minimum of 60 minutes prior to using for BTS optimization procedures. S Communications Test Set S Power Meter 5/21/04 1X SC4812T–MC BTS Optimization/ATP DRAFT 1-13 1 Required Test Equipment and Software Overview Test equipment and software described in this section is required for the optimization and acceptance testing procedures. Common tools such as screwdrivers and frame keys are also needed. Read the operators manual for all test equipment items to understand their individual operation before using them for optimization or acceptance testing. LMF Computer and Software LMF Hardware Requirements An LMF computer platform that meets the following requirements (or better) is recommended: NOTE Notebook computer 266 MHz (32–bit CPU) Pentium processor Windows 98 Second Edition (SE) or Windows 2000 operating system 4 GB internal hard disk drive SVGA 12.1–inch active matrix color display with 1024 x 768 (recommended) or 800 x 600 pixel resolution and capability to display more than 265 colors If 800 x 600 pixel resolution is used, the LMF window must be maximized after it is displayed. S Memory requirements: – Minimum required RAM: 96 MB – Recommended RAM: –– 128 MB for Windows 98 SE –– 256 MB for Windows 2000 1-14 20X CD ROM drive 3 1/2 inch floppy drive 56kbps V.90 modem Serial port (COM 1) Parallel port (LPT 1) PCMCIA Ethernet interface card (for example, 3COM Etherlink III) with a 10Base–T–to–coax adapter 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 Required Test Equipment and Software – continued LMF Software The Local Maintenance Facility (LMF) application program is a graphical user interface (GUI)–based software tool. This product is specifically designed to provide cellular communications field personnel with the capability to support the following CDMA BTS operations: S Installation S Maintenance S Calibration S Optimization Ethernet LAN Transceiver S PCMCIA Ethernet Adpater + Ethernet UTP Adapter: 3COM Model – Etherlink III 3C589B 10BaseT/10Base2 Converter S Transition Engineering Model E–CX–TBT–03 10BaseT/10Base2 Converter NOTE Xircom Model PE3–10B2 or equivalent can also be used to interface the LMF Ethernet connection to the frame. 3C–PC–COMBO CBL S Connects to the 3COM PCMCIA card and eliminates the need for a 10BaseT/10base2 Converter. RS–232 to GPIB Interface S National Instruments GPIB–232–CT with Motorola CGDSEDN04X RS232 serial null modem cable or equivalent; used to interface the LMF to the test equipment. S Standard RS–232 cable can be used with the following modifications (see Figure 1-5): – This solution passes only the 3 minimum electrical connections between the LMF and the General Purpose Information Bus (GPIB) interface. The control signals are jumpered as enabled on both ends of the RS–232 cable (9–pin D). TX and RX signals are crossed as Null Modem effect. Pin 5 is the ground reference. – Short pins 7 and 8 together, and short pins 1, 4, and 6 together on each connector. Figure 1-5: Null Modem Cable Detail 9–PIN D–FEMALE GND RX TX RTS CTS RSD/DCD DTR DSR 5/21/04 9–PIN D–FEMALE ON BOTH CONNECTORS: SHORT PINS 7 and 8; SHORT PINS 1, 4, and 6 1X SC4812T–MC BTS Optimization/ATP DRAFT GND TX RX RTS CTS RSD/DCD DTR DSR FW00362 1-15 1 Required Test Equipment and Software – continued MMI Interface Motorola cable part number CGDSMMICABLE219112 or a cable locally fabricated as described in Appendix J is used to connect the LMF to the BTS. Communications System Analyzer CDMA/analog Table 1-1: CDMA LMF Test Equipment Support Table Item Description Test Capability Test Sets Hewlett Packard, model HP 8921A (with 83203B) Communications analyzer (includes 83203B CDMA interface option) IS–95A/B only Hewlett Packard, model HP 83236A PCS interface for PCS band IS–95A/B only Motorola CyberTest Communications analyzer IS–95A/B only Advantest R3465 (with 3561L) Communications analyzer (with 3561 CDMA option) IS–95A/B only Agilent E4406A (with E4432B) Communications analyzer (with Generator) IS–95A/B and CDMA 2000 testing Advantest R3267 Analyzer (with R3562) Communications Analyzer with Advantest R3562 Generator IS–95A/B and CDMA 2000 testing Agilent 8935 series E6380A (formerly HP 8935) with option 200 or R2K Communications test set IS–95A/B and CDMA 2000 testing Agilent E7495A Communications test set IS–95A/B and CDMA 2000 testing Power Meters Gigatronix 8541C Power meter HP437B (with HP8481A sensor) Power meter with sensor – capable of measuring –30 dBm to 20 dBm A combination of test equipment supported by the LMF may also be used during optimization and testing of the RF communications portion of BTS equipment when the communications system analyzer does not perform all of the following functions: S Frequency counter Deviation meter RF power meter (average and code domain) RF signal generator (capable of DSAT/CDMA modulation) Audio signal generator AC voltmeter (with 600–ohm balanced audio input and high impedance input mode) S Noise measurement meter 1-16 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 Required Test Equipment and Software – continued S C–Message filter S Spectrum analyzer S CDMA code domain analyzer GPIB Cables S Hewlett Packard 10833A or equivalent; 1 to 2 meters (3 to 6 feet) long used to interconnect test equipment and LMF terminal. Timing Reference Cables S Two BNC-male to BNC-male RG316 cables; 3.05 m (10 ft.) long. Used to connect the communications analyzer to the front timing reference of the CSM cards in the BTS frame. Digital Multimeter S Fluke Model 8062A with Y8134 test lead kit or equivalent; used for precision dc and ac measurements, requiring 4–1/2 digits. Directional Coupler S Narda Model 30445 30 dB (Motorola Part No. 58D09643T01 ) 800 MHz coupler terminated with two Narda Model 375BN–M loads, or equivalent. RF Terminations/Loads S At least three 100–Watt (or larger) non–radiating RF terminations/loads. Miscellaneous RF Adapters, Loads, etc S As required to interface test cables and BTS equipment and for various test set ups. Should include at least two 50 Ohm loads (type N) for calibration and one RF short, two N–Type Female–to–Female Adapters. LAN Cable S BNC–to BNC 50 ohm coaxial cable [.91 m (3 ft) maximum] with an F–to–F adapter, used to connect the 10BaseT–to–coaxial adapter to the BTS LAN connector. High–impedance Conductive Wrist Strap S Motorola Model 42–80385A59; used to prevent damage from Electrostatic Discharge (ESD) when handling or working with modules. 5/21/04 1X SC4812T–MC BTS Optimization/ATP DRAFT 1-17 1 Required Test Equipment and Software – continued Optional Equipment NOTE Not all optional equipment specified here will be supported by the LMF in automated tests or when executing various measure type command line interface (CLI) commands. It is meant to serve as a list of additional equipment that might be required during maintenance and troubleshooting operations. Frequency Counter S Stanford Research Systems SR620 or equivalent. If direct measurement of the 3 MHz or 19.6608 MHz references is required. Spectrum Analyzer S Spectrum Analyzer (HP8594E with CDMA personality card) or equivalent; required for manual tests. Local Area Network (LAN) Tester S Model NETcat 800 LAN troubleshooter (or equivalent); used to supplement LAN tests using the ohmmeter. Span Line (T1/E1) Verification Equipment S As required for local application Oscilloscope S Tektronics Model 2445 or equivalent; for waveform viewing, timing, and measurements or during general troubleshooting procedure. 2–way Splitter S Mini–Circuits Model ZFSC–2–2500 or equivalent; provides the diversity receive input to the BTS High Stability 10 MHz Rubidium Standard S Stanford Research Systems SR625 or equivalent – required for CSM and Low Frequency Receiver/High Stability Oscillator (LFR/HSO) frequency verification. Itasca Alarms Test Box S Itasca CGDSCMIS00014 – This test box may be used as a tool to assist in the testing of customer alarms. 1-18 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 Required Documents and Related Publications Required Documents The following documents are required to perform optimization of the cell site equipment: S Site Document (generated by Motorola Systems Engineering), which includes: – General site information – Floor plan – RF power levels – Frequency plan (includes Site PN and operating frequencies) – Channel allocation (paging, traffic, etc.) – Board placement – Site wiring list – Site–specific CDF file S Demarcation Document (Scope of Work Agreement) S Equipment manuals for non-Motorola test equipment Related Publications Additional, detailed information about the installation, operation, and maintenance of the 1X SCt4812T–MC BTS and its components is included in the following publications: LMF Help function on–line documentation 1X SC 4812T-MC BTS Hardware Installation – 68P09260A38 1X SC 4812T-MC BTS FRU Guide – 68P09260A87 1X SC 4812T/ET/ET Lite/MC/T Lite BTS Troubleshooting Manual ; 68P09258A73 (packet) and 68P09258A74 (circuit) S LMF On-Line Help, Software Release 2.16.4.x – 68P09260A45 S LMF CDMA CLI Reference, Software Release 2.16.4.x – 68P09260A67 S MWR1900 Wireless Mobile Edge Router Hardware Installation Guide; part number 78–13982–01 S MWR1900 Wireless Mobile Edge Router Software Configuration Guide; part number 78–13983–01 S MWR1941–DC Mobile Wireless Edge Router Hardware Installation Guide; part number 78–15827–01 5/21/04 1X SC4812T–MC BTS Optimization/ATP DRAFT 1-19 1 Terms and Abbreviations Standard and Non–standard Terms and Abbreviations Standard terms and abbreviations used in this manual are defined in Glossary of Cellular Terms; 68P09213A95 and Cellular Acronyms; 68P09301A61. Any non–standard terms or abbreviations included in this manual are listed in Table 1-2. Table 1-2: Non–Standard Terms and Abbreviations Term or Abbreviation Definition 1X One of two bandwidths currently defined in the IS–2000 CDMA specification, which extends the capability of the IS–95A and B specifications. 1X bandwidth provides wireless packet voice and data transmission capability at up to 144 Mbps. BPR BTS Packet Router. Markings on GLI3 Fast Ethernet connectors and SC4812T Fast Ethernet interface housing. AR As Required BSS Base Station Subsystem (BSS). The BSS consists of a Radio Access Network (RAN), at least one Access Node (AN), and a pair of core routers. It may also include a Digital Access Crossconnect System (DACS) to support split backhaul and, under Software Release 2.16.1.x and higher, a Selector Distribution Unit (SDU). BTSRTR BTSRTRGRP BTS router BTS router group cage canned configuration C–CCP CEPT CF CNEOMI BTS RouTeR (see BTS router) BTS RouTeR GRouP (see BTS router group) One of the routers in a BTS router group. The single non–redundant router or redundant router pair required for network interface when a BTS is operating on packet backhaul. Used interchangeably with “shelf” in SC4812T/ET/ET Lite BTSs, as in Combined CDMA Channel Processor shelf. See minimum standard configuration. Combined–CDMA Channel Processor. CDMA cage type used by SC4812T and SC4812ET BTSs where assemblies previously mounted in a BTS distribution shelf are combined into the CCP cage. Conference of European Postal and Telecommunications Administrators Compact Flash. Type of flash memory card used in the BTS router to store the Internetwork Operating System and configuration files. Common Network Element Operation & Maintenance Interface table continued on next page 1-20 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 Terms and Abbreviations – continued Table 1-2: Non–Standard Terms and Abbreviations Term or Abbreviation CRMS circuit backhaul duplex router ESM Definition Cellular Radio Monitoring System Conventional, non–Internet Protocol (IP) backhaul between the BTS and the Central Base Station Controller (CBSC) transcoder (XC) which carries IS–95A/B traffic. See redundant router Ethernet Surge Module external BTS router MWR 1900 or MWR 1941 BTS routers mounted outside the C–CCP or SCCP cage of a packet BTS. FE Fast Ethernet. 100base–T mode of 10/100base–T Ethernet used for transmitting packetized control and bearer traffic between the BTS router group and GLI3 cards in the BTS. GLI3 high availability BTS router IBR Integrated BTS Router IOS minimum standard configuration mixed backhaul Third generation Group Line Interface card. Replaces GLI2 cards in a BTS when upgrading to packet backhaul capability under Software Release 2.16.1.x. Provides all the functionality of GLI2 cards plus additional capabilities needed for packet backhaul. GLI3 cards may only be installed in BSSs operating with Software Release 2.16.1.x software. See redundant router. Integrated BTS Router; see integrated BTS router A GLI3 card loaded with bootROM code which allows the card’s controller for Concentration Interface Highway (CHI) bus 2 to function as a router for packet traffic for the BTS. Employing IBRs permits converting a BTS to packet backhaul operation without using an external BTS router group. IBRs can operate as non–redundant or redundant BTS routers, but their employment limits BTS span capacity to one span as opposed to four spans for external BTS routers. Internetwork Operating System. Operating system software used by the external BTS routers. The initial minimum configuration data which must be loaded into a BTS router to enable it to communicate on the network. This standard “canned configuration” is generated by a script included in the R16.1 software load for the OMC–R/CBSC. Separate configuration files for the primary BTS router on each FE LAN at a site is created by the script and can be copied to the Compact Flash (CF) memory card containing the IOS for BTS routers. Once the CF card with the IOS and minimum standard configuration is installed, the BTS router can communicate with the OMC–IP and the full, site–specific router configuration file can be downloaded from the Mobile Wireless Center to the router. Different configuration files are required for circuit and packet backhaul operation. See split backhaul. table continued on next page 5/21/04 1X SC4812T–MC BTS Optimization/ATP DRAFT 1-21 1 Terms and Abbreviations – continued Table 1-2: Non–Standard Terms and Abbreviations Term or Abbreviation Definition MWC Mobile Wireless Center. One element of the OMC–IP which provides management and control for the MWR 1900 or MWR 1941 BTS routers installed in BTSs operating on packet backhaul. non–redundant router A BTS router group consisting of a single router without redundancy used as a cost–reduced network interface for a BTS operating on packet backhaul. original design frame +27 Vdc and –48 Vdc BTS frames in produced during early production of the product including starter and expansion frames. The FE Housing present on these frames is not located in the front middle of the top I/O panel, but located in different locations towards the rear of the unit, or on the right front side of the unit. +27 Vdc frames are 1800mm, –48 Vdc frames are 2100mm. Refer to the +27 Vdc or –48 Vdc Differences sections for a visual explanation of original production frames. packet backhaul IP–based backhaul between the BTS and the the network. Packet backhaul capability is implemented in Software Release 2.16.1.x and requires equipping a BTS with BTS routers and GLI3 cards. With the packet backhaul upgrade, a BTS can be configured for circuit operation with the capability to switch to packet backhaul or for packet–only operation. packet BTS A BTS operating on packet backhaul pBTS Packet BTS R15.x Motorola Software Release 2.15.0.39.10 or later. The version of the software which must be installed on BSS equipment to allow upgrading to Software Release 2.16.0.x. R16.0 Motorola Software Release 2.16.0.x. The version of the software which must be loaded on BSS equipment to upgrade it to software release 2.16.1.x. R16.1 Motorola Software Release 2.16.1.x. The earliest software release supporting packet backhaul. redundant router A BTS router group consisting of two MWR 1900 or MWR 1941 routers with Hot Standby Router Protocol (HSRP) to provide redundancy. SC4812TX C–CCP ROMmon simplex router An expansion frame version of the SC4812T–series BTS equipped with trunked RF power amplifiers and no receiver antenna ports. Combined – CDMA Channel Processor Low–level operating system used in MWR 1900 or MWR 1941 routers along with the IOS See non–redundant router. table continued on next page 1-22 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 Terms and Abbreviations – continued Table 1-2: Non–Standard Terms and Abbreviations Term or Abbreviation Definition split backhaul Backhaul serving a network in which IS–95A/B traffic and 1X data traffic are mixed on circuit backhaul from CDMA2000 1X BTSs. 1X data traffic is “split” from IS–95A/B on a single span by being transported on DS0 time slots dedicated to a “packet pipe.” IS–95A/B traffic is transported on the remaining DS0 time slots. Split backhaul on a single span must be connected to a Digital Access and Cross–connect System (DACS) which directs IS–95A/B traffic to the CBSC XC and 1X data traffic to the Access Node (AN), as required. If a DACS is not used, a CDMA2000 1X BTS must be equipped with separate spans for 1X data packet and IS–95A/B voice/data traffic, respectively. The 1X data packet–dedicated span would connect directly to the AN. The IS–95A/B–only span would connect directly to the CBSC XC. tftp updated design frame 5/21/04 trivial file transfer protocol +27 Vdc and –48 Vdc BTS frames that contain enhancements of the BTS product and include starter and expansion frames. The FE Housing present on these frames is located in the front middle of the top I/O panel. Both the +27 Vdc and the –48Vdc frames are 1800mm (original –48 Vdc frames are 2100mm).Another visual reference that helps determine the frame at the site is the location of the circuit breakers. The updated design frame provides the cage circuit breakers in the middle right section of the frame. Refer to the +27 Vdc or –48 Vdc Differences sections for a visual explanation of original production frames. Var. Variable WIC WAN Interface Card (also VWIC) 1X SC4812T–MC BTS Optimization/ATP DRAFT 1-23 1 BTS Equipment Identification Equipment Overview The BTS can consist of the following equipment frames: S At least one BTS starter frame – –48 V configuration shown in Figure 1-6 +27 V configuration shown in Figure 1-7 S Ancillary equipment frame (or wall mounted equipment) S One or more Expansion frames (see Figure 1-8 and Figure 1-9). Expansion frames are essentially the same as starter frames but incorporate unique components on the I/O (Interconnect) panel. NOTE I/O panel detail is provided for Starter Frame in Figure 1-12 and Expansion Frame in Figure 1-13 C–CCP cage details are provided in Figure 1-14 Logical BTS The BTS software implements the logical BTS capability. Previously, all BTS frames co–located at a single site had to be identified in the network with separate and distinct BTS ID numbers. In the Logical BTS feature, all frames located at a single BTS site are identified with unique Frame ID numbers (Frame ID Numbers 1, 101, 201, 301) under a single (site) BTS ID number. A logical BTS can consist of up to four frames. When the LMF is connected to frame 1 of a logical BTS, you can access all devices in all of the frames that make up the logical BTS. A logical BTS requires a CDF file that includes equipage information for all of the logical BTS frames and their devices and a CBSC file that includes channel data for all of the logical BTS fames. Logical BTS Numbering The first frame of a logical BTS has a –1 suffix (e.g., BTS–812–1). Other frames of the logical BTS are numbered with suffixes, –101, –201, and –301 (e. g. BTS–812–201). When you log into a BTS, a FRAME tab is displayed for each frame. If there is only one frame for the BTS, there is only one tab (e.g., FRAME–282–1) for BTS–282. If a logical BTS has more than one frame, there is a separate FRAME tab for each frame (e.g. FRAME–438–1, FRAME–438–101, and FRAME–438–201 for a BTS–438 that has three frames). Actions (e.g., ATP tests) can be initiated for selected devices in one or more frames of a logical BTS. Refer to the Select devices help screen for information on how to select devices. C–CCP Shelf Card/Module Device ID Numbers All cards/modules/boards in the frames at a single site, assigned to a single BTS number, are also identified with unique Device ID numbers dependent upon the Frame ID number in which they are located. Refer to Table 1-3 and Table 1-4 for specific C–CCP Shelf Device ID numbers. 1-24 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 BTS Equipment Identification – continued Table 1-3: C–CCP Shelf/Cage Card/Module Device ID Numbers (Top Shelf) Frame Card/Module ID Number (Left to Right) Power Power Power AMR GLI– (PS–1) (PS–2) (PS–3) –1 MCC BBX BBX– MPC/ EMPC –1 – – – R1 – 101 – – – 101 101 101 102 103 104 105 106 101 102 103 104 105 106 R101 – 201 – – – 201 201 201 202 203 204 205 206 201 202 203 204 205 206 R201 – 301 – – – 301 301 301 302 303 304 305 306 301 302 303 304 305 306 R301 – Table 1-4: C–CCP Shelf/Cage Card/Module Device ID Numbers (Bottom Shelf) Frame Card/Module ID Number (Left to Right) HSO/ CSM CSM CCD CCD LFR –1 –2 AMR GLI–2 –2 MCC 10 11 12 10 11 12 – – – – – 101 – 101 102 – – – 102 102 107 108 109 110 111 112 107 108 109 110 111 112 – – 201 – 201 202 – – – 202 202 207 208 209 210 211 212 207 208 209 210 211 212 – – 301 – 301 302 – – – 302 302 307 308 309 310 311 312 307 308 309 310 311 312 – – DRAFT MPC/ EMPC –2 – 1X SC4812T–MC BTS Optimization/ATP SW 5/21/04 BBX 1-25 1 BTS Equipment Identification – continued Figure 1-6: BTS Starter Frame (–48V) PHYSICAL APPEARANCE OF FRAMES: The physical appearance of the frame, especially the location of the MCM, Power Amplifier cage, and Power Distribution/Combiner cage, and the particular I/O plate FE Connector used, may differ on frames converted from early version SC4812T BTSs. Functionally however, and for the purpose of optimization and acceptance testing, those frames are identical. RGD Module (Installed when site is expanded) ÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂ ESM Fan Module Cable Channel Cover I/O Interconnect Plate (See NO TAG) C–CCP Cage Air Plenum Power Supply Modules C–CCP Cage and PA Breakers Power Supply Modules PA Cage Enhanced Trunking Module TX Filter or TX Terminators Power Alarms Card TX Filter Multi–Carrier Module (MCM) detail 1-26 For clarity, doors are not shown. ti-CDMA-WP-00320-v01-ildoc-ftw 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 BTS Equipment Identification – continued Figure 1-7: BTS Starter Frame (+27V) PHYSICAL APPEARANCE OF FRAMES: The physical appearance of the frame, especially the location of the MCM, Power Amplifier cage, and Power Distribution/Combiner cage, and the particular I/O plate used, may differ on frames converted from early version SC4812T BTSs. Functionally however, and for the purpose of optimization and acceptance testing, those frames are identical. FE Connector ÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂ ESM Fan Module RGD Module (Installed when site is expanded) I/O Interconnect Plate (See Figure 1-12) Cable Channel Cover C–CCP Cage C–CCP Cage and PA Breakers PA Cage Enhanced Trunking Module TX Filter or TX Terminators TX Filter Multi–Carrier Module (MCM) detail 5/21/04 For clarity, doors are not shown. ti-CDMA-WP-00317-v01-ildoc-ftw 1X SC4812T–MC BTS Optimization/ATP DRAFT 1-27 1 BTS Equipment Identification – continued Figure 1-8: BTS Expansion Frame (–48V) PHYSICAL APPEARANCE OF FRAMES: The physical appearance of the frame, especially the location of the MCM, Power Amplifier cage, and Power Distribution/Combiner cage, and the particular I/O plate Alarms used, may differ on frames converted from early version Span I/O A FE SC4812T BTSs. Functionally however, and for the purpose Connector of optimization and acceptance testing, those frames are Site I/O identical. Span I/O B ESM Exhaust Region Cable Channel Cover Fan Module ÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂ C–CCP Cage Filler Plate Input Connector/ DC Filter Expansion I/O Housing Air Plenum Power Supply Modules C–CCP Cage and PA Breakers Power Supply Modules PA Cage Power Alarms Card Enhanced Trunking Module TX Filter or TX Terminators TX Filter Multi–Carrier Module (MCM) detail 1-28 For clarity, doors are not shown. ti-CDMA-WP-00318-v01-ildoc-ftw 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 BTS Equipment Identification – continued Figure 1-9: BTS Expansion Frame (+27V) PHYSICAL APPEARANCE OF FRAMES: The physical appearance of the frame, especially the location of the MCM, Power Amplifier cage, and Power Distribution/Combiner cage, and the particular I/O plate used, may differ on frames converted from early version SC4812T BTSs. Functionally however, and for the purpose FE Connector of optimization and acceptance testing, those frames are identical. ESM Fan Module Cable Channel Cover ÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂ ÂÂÂÂÂÂÂÂÂÂÂ C–CCP Cage Air Plenum C–CCP Cage and PA Breakers PA Cage Enhanced Trunking Module TX Filter or TX Terminators TX Filter Multi–Carrier Module (MCM) detail For clarity, doors are not shown. ti-CDMA-WP-00319-v01-ildoc-ftw 5/21/04 1X SC4812T–MC BTS Optimization/ATP DRAFT 1-29 1 BTS Equipment Identification – continued Figure 1-10: BTS Multi–Carrier Frame 3 Sector PA Cage Configuration (+27V) PHYSICAL APPEARANCE OF FRAMES: The physical appearance of the frame, especially the location of the MCM, Power Amplifier cage, and Power Distribution/Combiner cage, and the particular I/O plate used, may differ on frames converted from early version SC4812T BTSs. Functionally however, and for the purpose of optimization and acceptance testing, those frames are identical. NOTE: The fourth PA quadrant (quadrant D– see Figure 1-15) is populated with CLPAs only whe the 4x4 ETM is used. For an SC4812T BTS frame which has been converted to multicarrier capability, a fourth three–sector carrier, using BBX–10 through BBX–12, is supported in R16.4 and later software releases. In a converted multicarrier frame, PA slot 4 in all PA quadrants should never be populated. PA Cage Enhanced Trunking Module TX Filters (one per sector) PA Cage ti-CDMA-WP-00210-v01-ildoc-ftw REF 1-30 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 BTS Equipment Identification – continued Figure 1-11: BTS Multi–Carrier Frame 6–Sector PA Cage Configuration (+27V) NOTE: The fourth PA quadrant (quadrant D – (see Figure 1-15) is populated with CLPAs only when the 4x4 ETM is used. Enhanced Trunking Module PA Cage TX Filters (one per sector) Enhanced Trunking Module PA Cage TX Filters (one per sector) ti-CDMA-WP-00196-v01-ildoc-ftw REF BTS Frame Description The BTS is the interface between the span lines to/from the Centralized Base Station Controller (CBSC) and the site antennas. This frame is described in three sections: S The top interconnect panel where all connections are made. S The upper portion of the frame which contains circuit breakers, cooling fans, and the C–CCP shelf. S The lower portion of the frame which contains the PAs and PA fans, Parallel Linear amplifier Combiners (PLC), Enhanced Trunking Module(s) (ETM), and TX filters. 5/21/04 1X SC4812T–MC BTS Optimization/ATP DRAFT 1-31 1 BTS Equipment Identification – continued Top Interconnect (I/O) Panel All cabling to and from the BTS equipment frames is accomplished at the I/O panel (seeFigure 1-12and Figure 1-13) on top of each frame. The I/O panel layout is identical for +27V and –48V frames starter and expansion frames with the exception that the power input label is voltage–specific and the RX Expansion port location changes as shown inFigure 1-12and Figure 1-13. Connections at the I/O panel include: 1-32 Span lines RGPS Distribution (RGD) card RX antennas TX antenna Alarm connections Power input LAN connections RF GPS input or Remote Global Positioning System (RGPS) on the Site I/O Board Expansion frame connection Ground connections ESM 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 BTS Equipment Identification – continued Figure 1-12: Starter Frame I/O Panel REMOTE GPS DISTRIBUTION (RGD) MODULE USED ONLY IF EXPANSION FRAME(S) INSTALLED AND RGPS IS USED. SPAN I/O SITE I/O SPAN I/O RGPS REAR RECEIVE LAN ANTENNA CONNECTORS CONNECTIONS SITE I/O SPAN I/O B ALARM CONNECTORS SPAN I/O A RX ALARM B ALARM A GND 1A 4A 2A 5A 3A 6A 1B 4B RF GPS IN HSO/LFR SPAN I/O B 2B 5B 3B 6B DC FILTER 2 SITE I/O DC FILTER 1 SPAN I/O A RX 5/21/04 FAST ETHERNET INTERFACE HOUSING (IF USED; OTHERWISE, FILLER PLATE USED ON ETHERNET ROUTER OPENING) EXP IN FILLER PLATE INPUT CONNECTOR/ DC FILTER POWER INPUT LABEL WILL BE VOLTAGE SPECIFIC 3 TO 6 TRANSMIT ANTENNA CONNECTORS (DEPENDING ON CONFIGURATION) 2 TO 3 TRANSMIT ANTENNA FILLER PLATES (DEPENDING ON CONFIGURATION) FRONT ESM FILLER PLATE RF EXPANSION PORT TO ANOTHER BTS (USED ONLY IF EXPANSION FRAME INSTALLED; OTHERWISE, FILLER PLATE INSTALLED) ti-CDMA-WP-00188-v02-ildoc-ftw 1X SC4812T–MC BTS Optimization/ATP DRAFT 1-33 BTS Equipment Identification – continued Figure 1-13: Expansion Frame I/O Panel SPAN I/O SITE I/O SPAN I/O REAR SITE I/O LAN CONNECTIONS SPAN I/O A RX ALARM B ALARM A SITE I/O 1A 4A 2A 5A GPS IN HSO/LFR SPAN I/O B 3A 6A 1B 4B 2B 5B 3B 6B DC FILTER 2 SPAN I/O A GND DC FILTER 1 ALARM CONNECTORS RECEIVE ANTENNA COVERS SPAN I/O B RX FRONT FAST ETHERNET INTERFACE HOUSING EXP OUT (IF USED; OTHERWISE, FILLER PLATE FILLER PLATE USED ON ETHERNET ROUTER OPENING) 1-34 RF EXPANSION PORT FROM STARTER BTS 1X SC4812T–MC BTS Optimization/ATP DRAFT FILLER PLATE INPUT CONNECTOR/ DC FILTER 3 to 6 TX ANTENNA CONNECTORS (depending on configuration) 2 to 3 TX ANTENNA FILLER PLATES (depending on configuration) ti-CDMA-WP-00188-V03-ildoc-ftw 5/21/04 BTS Equipment Identification – continued C–CCP Shelf The upper portion of the frame houses circuit breakers, cooling fans, and the Combined–CDMA Channel Processor (C–CCP) shelf (see Figure 1-14). The C–CCP shelf includes: S C–CCP backplane and cage S C–CCP power supplies S CDMA Clock Distribution (CCD) cards S CSM and HSO/LFR cards S Alarm Monitoring and Reporting (AMR) cards S GLI cards S Multcoupler Preselector Card (MPC) (starter frame)/Expansion MPC (EMPC) (expansion frame) cards S Switch card S MCC cards S BBX cards S MCIO cards MPC/EMPC–1 MPC/EMPC–2 Switch BBX–12 BBX–11 BBX–10 BBX–9 BBX–8 BBX–7 MCC–12 MCC–11 MCC–10 MCC–9 MCC–8 MCC–7 GLI–2 NOTE: MCCs may be MCC24Es, MCC8Es, or MCC–1Xs. GLIs may be GLI2s or GLI3s. AMR–2 38 mm Filler Panel CCD–2 CSM–2 CSM–1 HSO/LFR CCD–1 MCIO BBX–6 BBX–R BBX–5 BBX–4 BBX–3 BBX–2 BBX–1 MCC–6 MCC–5 MCC–4 MCC–3 MCC–2 GLI–1 MCC–1 AMR–1 PS–3 PS–2 PS–1 19 mm Filler Panel Figure 1-14: C–CCP Shelf ti-CDMA-WP-00037-v01-ildoc-ftw REF 5/21/04 1X SC4812T–MC BTS Optimization/ATP DRAFT 1-35 1 BTS Equipment Identification – continued NOTE For an SC4812T BTS frame which has been converted to multicarrier capability, a fourth three–sector carrier, using BBX–10 through BBX–12, is supported in R16.4 and later software releases. In a converted multicarrier frame, PA slot 4 in all PA quadrants should never be populated. PA Shelves The lower shelves house the PA cages which include: S PA modules, PA fans, and Parallel Linear amplifier Combiners (PLCs) S Multi–Carrier Module (MCM) which includes the Enhanced Trunking Modules (ETMs), and TX filters Location Nomenclature Figure 1-15 presents standardized nomenclature for locations within the PA cages. Figure 1-15: PA Cage Location Nomenclature (Original Equipment Manufacture (OEM) SC4812T–MC 3–Sector Shown) PA Slot 1 Quadrant A PA Slot 2 CLPA 1A MCM CLPA 2A CLPA 3A PA Slot 3 CLPA 1B CLPA 2B S3 CLPA 3B Quadrant B S2 PA Slot 4 CLPA 4A S1 CLPA 1C Quadrant C CLPA 2C CLPA 3C CLPA 4C CLPA 4B CLPA 1D CLPA 2D CLPA 3D Quadrant D CLPA 4D PAs and Carriers With changes in the network software for R16.4.1, PA allocation to carriers in the SC4812T–MC changes significantly. The quantity of PAs required is no longer dependant on the number of carriers equipped in the frame. Implementation of the change differs between six sector BTSs and BTSs equipped for omni, two–sector, and three–sector operation. Additional details for each BTS sector configuration are provided in the following paragraphs and Figure 1-20, Figure 1-21, and Figure 1-22. Omni, two–sector, and three–sector multicarrier BTS – Up to four carriers can be supported on an omni, two–, or three–sector BTS with one PA set. If additional power output is required, additional PA sets can be added up to the maximum of four sets. PAs must be added as complete sets; that is, three PA modules for a 3x3 system and four PA modules for a 4x4 system. (Refer to Figure 1-20 and Figure 1-21) 1-36 1X SC4812T–MC BTS Optimization/ATP DRAFT 5/21/04 BTS Equipment Identification – continued Six–sector BTS – Six–sector operation is only supported in OEM multicarrier frames. For a six–sector BTS, up to two carriers can be supported with a minmum of two PA sets: six PA modules for a 3x3 system and eight PA modules for a 4x4 system. If additional power is required, two additional PA sets can be added for the maximum available capacity. (Refer to Figure 1-22). Equipment Configurations The various components of the PA cages may be configured differently depending upon customer requirements. Table 1-5 provides BTS carrier/sector/BBX mapping, TX Filter requirements, and PA quantities and configurations needed to provide the required BTS output power for all carriers. Figure 1-16 illustrates which BBXs are used for omni and two–sector operation. Figure 1-20, Figure 1-21, and Figure 1-22 illustrate the minimum and maximum power PA configurations for omni, two–, and three–sector OEM and converted multicarrier frames and for six–sector OEM multicarrier frames, respectively. Table 1-5: BTS Carrier/Sector/BBX Mapping and ETM/PA Quantities and Power Configurations Sec – Car– tors riers BBXs TX Assigned ETM (MCM) Filter to Qty Qty Carrier 3x3 ETM (Standard Power) PA Qty Required 4x4 ETM (High Power) PLC Qty PA Qty Required 1,2,3 Minimum power configuration: 1 PA set in slot 1 of quadrants A g C ((total of 3 CLPAs). through Minimum power configuration: 1 PA set in slot 1 of quadrants A g D ((total of 4 CLPAs). through 7,8,9 Additionally required power: achieved by adding additional PA sets to a maximum of: Additionally required power: achieved by adding additional PA sets to a maximum of: 4,5,6 – OEM multicarrier frames: 4 sets in quadrants A through C ((total of 12 CLPAs)) 10,11,12 – Converted multicarrier frames: 3 sets in quadrants A through C (total of 9 CLPAs) – OEM multicarrier frames: 4 sets in quadrants A through D ((total of 16 CLPAs)) PLC Qty – Converted multicarrier frames: 3 sets in quadrants A through D (total of 12 CLPAs) NOTE Six–sector operation is not available in converted multicarrier frames. Minimum power configuration: two PA sets, one in slot 1 and one in slot 3 of quadrants A through C (total of 6 CLPAs) (OEM multicarrier frames only). 1,2,3, 4,5,6 5/21/04 7,8,9, 10,11,12 Additionally required power: achieved by adding two additional PA sets, one in slot 2 and one in slot 4 of quadrants A through C (total of 12 CLPAs) (OEM multicarrier frames only). Minimum power configuration: two PA sets, one in slot 1 and one in slot 3 of quadrants A through D (total of 8 CLPAs) (OEM multicarrier frames only). Additionally required power: achieved by adding two additional PA sets, one in slot 2 and one in slot 4 of quadrants A through D (total of 16 CLPAs) (OEM multicarrier frames only). 1X SC4812T–MC BTS Optimization/ATP DRAFT 1-37
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Modify Date : 2004:06:01 10:18:37-05:00 Create Date : 2004:06:01 10:18:23-05:00 Title : Document1 Author : WLMV00 Creator : Document1 - Microsoft Word Producer : Acrobat PDFWriter 4.05 for Windows NT Page Count : 50 Mod Date : 2004:06:01 10:18:37-05:00 Creation Date : 2004:06:01 10:18:23-05:00 Metadata Date : 2004:06:01 10:18:37-05:00EXIF Metadata provided by EXIF.tools