Nokia 8310 User Manual To The F5d063ee 317a 4a4e 943e 14bb9797b71c
User Manual: Nokia 8310 to the manual
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
INSTALLATION INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS! 8˝ Round Fan MODEL: 8310 IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. B. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. CAUTION: For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. INSTALLATION INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. B. Sufficient air is needed for proper combusition and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. D. Ducted fans must always be vented to the outdoors. E. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application. F. NEVER place a switch where it can be reached from a tub or shower. • Do not mount over tub or in shower enclosure. • Suitable for use with solid-state speed controls. If the installation presents a problem that is not explained here or if any parts of these instructions are not clear, consult a professional installer. If you are not familiar with methods of installing electrical wiring, or if you are not certain as to the correctness of any step or procedure described, secure the services of a qualified electrician. INSTALLING THE HOUSING • Cutout dimension: 9" diameter • Blade Size: 8" • Grille Diameter: 101⁄2" MPORTANT: Remove shipping tape that secures louver. 1. Slide hanger bars (adjustable for 24" O.C. joists) through tabs in housing. Nail one hanger bar to joist and slide ventilator to desired position. Nail second hanger bar to joist: cocking it slightly to clamp fan into place. MAKING CONNECTIONS IMPORTANT: Prior to making wiring connections, disconnect electrical power at the main source and leave it off until the installation is complete. All wiring must comply with electrical codes. 1. Refer to Figure 1. Place wiring into the outlet box. Secure the connections with approved wire connectors and replace the cover plate. 2. Refer to Figure 2. Run 120vAC wiring (with ground) from main source through wall switch to the fan location. 3. Using wire nuts, connect supply wires to fan wires as follows: black to black, white to white. Connect ground wire to green ground screw. 4. Use electrical tape to insulate all wire nut connections. 5. Replace junction box cover and secure with screw. 6. Refer to Figure 3. Install outside wall cap with flange against outside of brick or sheathing, allowing sufficient room around flange for caulking. Connect discharge opening in fan housing to outside wall cap with standard 31⁄2" x 10" duct. 7. Refer to Figure 4. For vertical discharge installations, use elbow and 31⁄4" x 10" ductwork extended into roof cap. FAN JUNCTION BOX BLACK HOT WHITE COMMON GREEN GROUND 120vAC 60 Hz FIGURE 2 90° ELBOW WALL VENT WALL FAN BLACK HOT WHITE COMMON FIGURE 3 GREEN GROUND ROOF VENT GROUND SCREW 90° ELBOW FIGURE 1 FAN EAVE VENT FIGURE 4 FINAL ASSEMBLY INSTRUCTIONS 1. Check louvers in fan housing and outside wall cap to see that they are not damaged or binding. Louvre can be readily removed by depressing spring bearings on end of hinge pins. Refer to Figure 5. Install motor and blade assembly into housing. Be sure motor leads are toward receptacle. Plug motor lead into receptacle. Spin blade to be sure it turns freely. 2. Fasten grille in place with thumbscrew (furnished.) BE SURE UNIT AND SWITCHES ARE PROPERLY GROUNDED AND ALL WIRING COMPLIES WITH LOCAL CODE REQUIREMENTS. MAINTENANCE AND CLEANING FILTER To clean the filter (optional,) soak in hot, sudsy water. Rinse thoroughly and allow to dry. GRILLE Use only a mild soap and water solution to clean the grille. Do not use abrasive cleaners. FIGURE 5 One Year Limited Warranty WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one (1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by NuTone), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. WARRANTY SERVICE: To qualify for warranty service, you must (a) notify NuTone at the address stated below or telephone 1/800-543-8687, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. Date of Installation Builder or Installer Model No. and Product Description IF YOU NEED ASSISTANCE OR SERVICE: For the location of your nearest NuTone Independent Authorized Service Center: Residents of the contiguous United States Dial Free 1-800-543-8687 Please be prepared to provide: Product model number • Date and Proof of purchase • The nature of the difficulty Residents of Alaska or Hawaii should write to: NuTone Inc. Attn: Department of National Field Service, 4820 Red Bank Road, Cincinnati Ohio 45227-1599. Residents of Canada should write to: Broan-NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9. Rev. 03/2001 Product specifications subject to change without notice. 4820 Red Bank Road, Cincinnati, Ohio 45227 Printed in U.S.A., Rev. 4/01, Part No. 15851
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : Yes Create Date : 2001:04:24 11:00:13 Producer : Acrobat Distiller 4.0 for Macintosh Modify Date : 2001:04:24 11:00:24Z Page Count : 4EXIF Metadata provided by EXIF.tools