Nortek Security and Control 2GIG PAD1345 Wireless Security Remote Key Fob User Manual

2GIG Technologies, Inc. Wireless Security Remote Key Fob

User manual

Download: Nortek Security and Control 2GIG PAD1345 Wireless Security Remote Key Fob User Manual
Mirror Download [FCC.gov]Nortek Security and Control 2GIG PAD1345 Wireless Security Remote Key Fob User Manual
Document ID1160970
Application ID/BMB2PJmCd1syvio/flIpQ==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize20.88kB (261026 bits)
Date Submitted2009-08-28 00:00:00
Date Available2009-08-28 00:00:00
Creation Date2009-05-19 20:35:16
Producing SoftwareMicrosoft® Office Publisher 2007
Document Lastmod2009-05-19 20:35:16
Document TitleUser manual
Document CreatorMicrosoft® Office Publisher 2007
Document Author: dglassman

Wireless Keypad
grammed for voice annunciation.
2GIG-PAD1-345
•
•
•
•
Operating Instructions
Press INSERT to place a word from the vocabulary into the data entry field.
Use the ← or → arrows to scroll through the words, or enter the word’s 3-digit index number.
Press INSERT again for the next word. Up to five words are allowed.
To remove a word, press DELETE.
The 2GIG-PAD1-345 is a Wireless Keypad with stay and away arming options as well as fire and panic emergency functions.
Battery Installation & Replacement
Installation & Mounting Guidelines
To install or replace the battery, do the following:
1.
Remove keypad from mounting plate (see Installation & Mounting Guidelines).
2.
Place a small flathead screwdriver in the slot between the metal clip (see Figure 2) and the battery and twist the screwdriver
slightly while holding back one of the black plastic edges holding the battery.
3.
Insert the replacement battery with the + sign facing out. (see Figure 2)
4.
Verify programming and RF communication with the panel. (see Programming).
1.
2.
3.
4.
Use only the recommended replacement batteries (see Specifications).
Simultaneously press both tabs on top of the keypad to separate
mounting plate from main keypad.
Place mounting plate in desired location and ensure the plate is level
(see Figure 1).
Secure the mounting plate with 4 screws in the provided holes (see
Figure 1).
Reattach main keypad by inserting bottom portion first, folding upward
and snapping into place (see Figure 2).
WARNING! The polarity of the battery must be observed, as shown (see Figure 2). Improper handling of lithium
batteries may result in heat generation, explosion or fire, which may lead to personal injuries. Replace only with the
same or equivalent type of battery as recommended by the manufacturer. (see Specifications)
Batteries must not be recharged, disassembled or disposed of in fire. Disposal of used batteries must be made in accordance with the waste recovery and recycling regulations in your area.
Keep away from small children. If batteries are swallowed, promptly see a doctor.
California Only: This Perchlorate warning applies only to Manganese Dioxide Lithium cells sold or distributed ONLY in California,
USA. Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate.
Specifications
Figure 2
Figure 1
Programming
Select RF keypad # (1-4)
Up to four wireless keypads can be used with each Control Panel. The options for each sensor are programmed
with sub-option questions.
• Begin by entering the RF keypad number or select it using the ← or → arrows.
• Use the ↑ and ↓ arrows to select the sub-options.
Select RF keypad (#) used (0-1)
RF keypads can be used with the Control Panel or not.
DEFAULT: Unused (0)
• The default (0) sets all RF keypads as unused.
• To enable programming for this RF keypad, select used (1).
Enter RF keypad (#) serial number (7 digits)
DEFAULT: F000000
RF keypad serial numbers can be manually entered or learned from the RF keypad.
• For manual entry, enter the RF keypad number that was logged for the RF keypad being pro
grammed. Use the SHIFT button to access alpha characters.
• For automatic entry press SHIFT then press LEARN.
Wireless Signal Range
Code Outputs
Transmitter Frequency
Transmitter Frequency Tolerance
Transmitter Bandwidth
Modulation Type
Unique ID Codes
Supervisory Interval
Peak Field Strength
Dimensions (WxHxD)
Weight (including battery & bracket)
Housing Material
Color
Operating Temperature
Relative Humidity
Battery (installed)
Battery Life
Regulatory Listing(s)
Warranty*
Included Accessories
750 ft., open air, with 2GIG Wireless Alarm Control Panel
Key press 0-9; *; #; STAY; AWAY; FIRE; POLICE
345.000 MHz (crystal controlled)
± 10 kHz
24 kHz
Amplitude Shift Keying—On/Off Keying (ASK-OOK)
Over one (1) million different code combinations
70 minutes
Typical 50,000 uV/m at 3m
5.73 x 4.25 x 1.00 in. (14.6 x 0.8 x 2.5 cm)
7.75 oz. (219.7 g)
ABS plastic and poly-carbonate
White with gray trim
32° to 120°F (0° to 49°C)
5-95% Non-Condensing
Two (2) Panasonic CR2032, 3VDC, 225 mAh or equivalent Lithium coin batteries
5 years
ETL, FCC Part 15, Industry Canada
Two (2) years
Four (4) Phillip’s head screws, four (4) plastic wall anchors
FCC COMPLIANCE STATEMENT*
This device complies with FCC Rules and Regulations as Part 15 devices, as well as Industry Canada Rules and Regulations.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.
Note: Changes or modifications to the device may void FCC compliance.
FCC ID: WDQ-PAD1345
Industry Canada ID: 7794A-PAD1345
*For more warranty and compliance information, visit our website (www.2gig.com).
The Control Panel will wait for a RF keypad transmission. Trigger the RF keypad being programmed and the
Control Panel will learn the RF keypad’s serial number.
Select RF keypad (#) equipment age (0-1)
DEFAULT: New (0)
The Control Panel can be used with new or existing RF keypads.
• If this RF keypad is new for the installation, leave the default of new (0)
• If this RF keypad is already installed, select existing (1).
Select RF keypad (#) emergency key (0-1)
DEFAULT: Disabled (0)
RF keypads have 24-hour emergency buttons labeled FIRE and POLICE.
• The default (0) disables this RF keypad’s emergency keys.
• To use this RF keypad’s emergency keys, select enable (1).
Construct RF keypad (#) voice descriptor
DEFAULT: No default
The voice descriptor is the words the Control Panel will announce for this RF keypad if this RF keypad is pro-
Technical Support:
1-866-670-1591
www.2gig.com
05/19/09
©2009

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 1
Language                        : en-US
Tagged PDF                      : Yes
Author                          : dglassman
Create Date                     : 2009:05:19 20:35:16
Modify Date                     : 2009:05:19 20:35:16
Producer                        : Microsoft® Office Publisher 2007
Creator                         : Microsoft® Office Publisher 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: WDQ-PAD1345

Navigation menu