Nortek Security and Control 2GIG SMO1345 Wireless Smoke Sensor User Manual 229910A indd
2GIG Technologies, Inc. Wireless Smoke Sensor 229910A indd
User manual
PRINTERS INSTRUCTIONS INSTR,INSTL,2GIG-SMKE1-345 - P/N: 229910 X3 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - SIDE 1 of 2 PRODUCT DESCRIPTION 2GIG-SMKE1-345 The 2GIG-SMKE1-345 is a photoelectric smoke alarm with a built-in transmitter designed for use with the 2GIG-CNTRL-345 security system. When smoke is detected, the alarm sounds a loud local alarm. Twenty seconds after the local alarm sounds, the built-in transmitter sends a digitally coded wireless signal to the Control Panel. The wireless signal will be repeated every 20 seconds as long as smoke is still present. WIRELESS PHOTOELECTRIC SMOKE ALARM The 2GIG-SMKE1-345 detector can send four different signals: alarm, test, low battery, and status. The Control Panel must be programmed to the detector’s serial number before system testing and operation. Refer to the Control Panel’s instructions for details on programming. REMOVE PROTECTIVE COVER REMOVE PROTECTIVE COVER AND DISCARD The detector is powered by a 3-volt lithium battery. The battery is supplied with the detector and can power the unit for up to five years. If the battery voltage drops below a preset level the alarm will sound low battery beeps and a low battery signal will be sent to the Control Panel. Installation Instructions CM L IS T Every hour, the detector will send a status transmission to the Control Panel. The hourly signal updates the Control Panel with the detector’s condition. By monitoring status transmissions, the Control Panel can determine that the detector is still present in the installation and if it has a low battery. Maintenance: Occasionally clean the outside casing with a cloth. Ensure that the holes on the front of the alarm are not blocked with dirt and dust. Do not paint, and do not use cleaning agents, bleach, or polish on the detector. Technical Support 866-670-1591 www.2gig.com REMOVE MOUNTING PLATE TWIST MOUNTING PLATE TO UNLOCK REMOVE BATTERY TAB CHOOSE ALARM LOCATION PULL TO CONNEC BATTERIES REMOVE BATTERY TAB TO APPLY POWER REMOVE MOUNTING PLATE INSTALL MOUNTING PLATE SCREW ANCHORS FOR WALLBOARD 3-VOLT LITHIUM BATTERY TYPES: DURACELL DL123A, PANASONIC CR123A, SANYO CR123A, ADEMCO 466 PROGRAM CONTROL PANEL REFER TO CONTROL PANEL'S INSTRUCTIONS TO PREPARE RECEIVER TO ACCEPT THE DETECTOR'S SERIAL NUMBER MOUNT ALARM ON PLATE MATCH ALIGNMENT TABS IN PLATE WITH TABS IN COVER PRESS AND RELEASE TEST BUTTON TO SEND SIGNAL OR DETECTOR PLASTIC SINGLE-GANG ELECTRICAL BOX A TEST SIGNAL WILL BE SENT AS SOON AS THE SWITCH IS RELEASED CONTROL PANEL TWIST SMOKE ALARM CLOCKWISE TO LOCK ONTO MOUNTING PLATE PRINTERS INSTRUCTIONS INSTR,INSTL,2GIG-SMKE1-345 - P/N: 229910 X3 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - SIDE 2 of 2 TEST SYSTEM LOW BATTERY CONDITION When the alarm detects a low battery, the sounder will chirp and the red LED will blink every 45 seconds. The green LED will be off. Pressing the test switch will silence the chirp for 12 hours but will not affect the LEDs. During this silence period, the test switch is disabled. If an alarm condition occurs while the detector is in this chirp silence mode, the alarm will sound. Once the alarm condition has been removed and the detector returns to the standby state, the low battery chirp will resume every 45 seconds. TO TEST AN ACTUAL FIRE ALARM RESPONSE OF THE SYSTEM, TEST SWITCH MUST BE HELD FOR 20 SECONDS STANDARD FOR ALARM LOCATION VERIFY THAT CONTROL PANEL ACTIVATES DETECTOR LED INDICATORS At Power up = Green/Red blinks every 5 seconds Standby = Green blinks every 10 seconds Alarm = Red blinks every 1 second Maintenance = Red blinks every 5 seconds Low Battery = Red blinks every 45 seconds ✔ Ceiling mounted smoke alarms should be located in the center of the room or hall, or not less than 4 inches from any wall. When the alarm is mounted on a wall, the top of the alarm should be 4 to 12 inches from the ceiling. ✔ Do not install smoke alarms where normal ambient temperatures are above 100°F (37.8°C), or below 40°F (4°C). Also, do not locate alarm in front of air conditioners, heating registers, or other locations where normal air circulation will keep smoke from entering the detector. A-2.5.2.1 Smoke Detection - Are More Smoke Alarms Desirable? The required number of smoke alarms might not provide reliable early warning protection for those areas separated by a door from the areas protected 2-1.1.1 Smoke alarms shall be installed outside of each by the required smoke alarms. For this reason, it is recommended that the separate sleeping area in the immediate vicinity of the bedrooms householder consider the use of additional smoke alarms for those areas and on each additional story of the family living unit including for increased protection. The additional areas include the basement, basements and excluding crawl spaces and unfinished attics. bedrooms, dining room, furnace room, utility room, and hallways not In new construction, a smoke alarm shall be installed in each protected by the required smoke alarms. The installation of smoke alarms in kitchens, attics (finished or unfinished), or garages is not normally sleeping room. recommended, as these locations occasionally experience conditions 2-1.1.2 For family living units with one or more split levels (i.e., that can result in improper operation. The smoke alarm should be installed in accordance with National Fire Protection Association (NFPA) Standard 72, which reads as follows: adjacent levels with less than one full story separation between Smoke alarms are not to be used with detector guards unless the levels), a smoke alarm required by 2-1.1.1 shall suffice for an combination has been evaluated and found suitable for the purpose. adjacent lower level, including basements. (Exception: Where there is an intervening door between one level and the adjacent lower level, a smoke alarm shall be installed on the lower level.) FIRE PREVENTION AND ESCAPE The purpose of an early warning smoke alarm is to detect the presence of fire in its early stages, and sound an alarm giving the occupants more time to exit the premise before the smoke reaches a dangerous concentration level. Fires start even with the best of housekeeping and fire prevention procedures. Fire is an unexpected event. Early warning detection alerts occupants in time to act. KNOW FIRE HAZARDS. No detection device can protect life in all situations. Therefore, safeguards should be taken to avoid such potentially dangerous situations as: smoking in bed, leaving children home alone, cleaning with flammable liquids such as gasoline. The best fire protection is minimizing fire hazards through proper storage of materials and general good housekeeping techniques. A cluttered basement, attic, or other storage area is an open invitation to fire. Careless use of combustible materials and electrical appliances, or overloading of electrical outlets are other prime causes in starting fires. It is most important that explosive and/or fast burning materials be eliminated from the home, if at all possible. Even after proper precautions have been taken, fires can start. Be prepared. IN CASE OF FIRE. Leave immediately. Don’t stop to pack or search for valuables. In heavy smoke, hold your breath and stay low - crawl if necessary. The clearest air is usually at the floor. If you have to go through a closed door, carefully feel the door and door knob to see if undue heat is present. If they seem relatively cool, brace your foot against the bottom of the door with your hip against the door and one hand against the top edge. Open it slightly. If a rush of hot air is felt, slam the door quickly and latch it. Unvented fire tends to build up considerable pressure. Be sure all the household realizes and understands this danger. Use your neighbor’s phone or a street fire alarm box. The job of extinguishing the fire should be left to the professionals. Too many unforeseen things can occur when inexperienced people try to extinguish a fire. FCC COMPLIANCE STATEMENT This device complies with FCC Rules Part 15. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. BE PREPARED. Perform fire drills regularly. Use them to assure recognition of an alarm signal. For your protection, simulate different circumstances (smoke in hall, in living room, etc.). Then have everyone react to the situation. Draw a floor plan and show two exits from each room. Frequently a knotted rope or ladder from a window will serve this purpose. It is important that children be instructed carefully, because they tend to hide in times of crisis. It is imperative that one meeting place outside the home be established. You should insist that everyone meet there during an alarm. This will eliminate the tragedy of someone re-entering the house for a missing member who is actually safe. If you have children and/or invalids residing in your household, you can help your fire department. Most fire departments have window decals available for use in children’s or invalid’s bedrooms. Properly used, these decals will quickly identify sleeping quarters of these individuals and show the fire department where to look first for members of your household. ✔ Additional information on Household Fire Warning is available at nominal cost from: The National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. Request Standard No. NFPA 72 EXAMPLE ALARM LOCATIONS LIMITED WARRANTY This 2GIG Technologies product is warranted against defects in material and workmanship for two (2) years. This warranty extends only to wholesale customers who buy direct from 2GIG Technologies or through 2GIG Technologies’ normal distribution channels. 2GIG Technologies does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of 2GIG Technologies for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fitness, are valid only until the warranty expires. This 2GIG Technologies Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact 2GIG Technologies at 1-866-670-1591 for an RPA# and other important details. For additional warranty and compliance information, visit our Web site at: www.2gig.com IMPORTANT!!! Radio controls provide a reliable communications link and fill an important need in portable wireless signaling. However, there are some limitations which must be observed. ✶ For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15 devices. As such, they have limited transmitter power and therefore limited range. ✶ A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings. ✶ Changes or modifications to the device may void FCC compliance. ✶ Infrequently used radio links should be tested regularly to protect against undetected interference or fault. ✶ A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users. Copyright © 2009 229910 X3
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 8.1.0 (Windows) Keywords : Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2009:06:08 09:08:43-07:00 Create Date : 2009:06:08 08:56:45-07:00 Metadata Date : 2009:06:08 09:08:43-07:00 Format : application/pdf Title : 229910A.indd Creator : Copyright © 2009 Linear LLC Document ID : uuid:e68a9740-462b-417c-80df-6958ac2c9fd9 Instance ID : uuid:b934e514-a876-4e20-ab83-102a257aa847 Startup Profile : Print Page Count : 2 Author : Copyright © 2009 Linear LLC Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools