Nortek Security and Control 00144 Wireless Multi-Function Sensor / Wireless PIR Motion Sensor User Manual 10012103X4M4IN1Z 1 Instructions indd

Nortek Security & Control LLC Wireless Multi-Function Sensor / Wireless PIR Motion Sensor 10012103X4M4IN1Z 1 Instructions indd

Contents

User Manual_M4IN1Z-1

Download: Nortek Security and Control 00144 Wireless Multi-Function Sensor / Wireless PIR Motion Sensor User Manual 10012103X4M4IN1Z 1 Instructions indd
Mirror Download [FCC.gov]Nortek Security and Control 00144 Wireless Multi-Function Sensor / Wireless PIR Motion Sensor User Manual 10012103X4M4IN1Z 1 Instructions indd
Document ID3019538
Application IDZv0buu8k/M22KZ+iC5dP8w==
Document DescriptionUser Manual_M4IN1Z-1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize40.84kB (510521 bits)
Date Submitted2016-06-07 00:00:00
Date Available2016-06-07 00:00:00
Creation Date2016-05-24 10:04:46
Producing SoftwareAcrobat Distiller 10.1.16 (Windows)
Document Lastmod2016-05-24 10:05:34
Document Title10012103X4M4IN1Z-1 Instructions.indd
Document CreatorPScript5.dll Version 5.2.2
Document Author: Copyright © 2016 Nortek Security & Control

PRINTER’S INSTRUCTIONS:
INSTR,INSTL,M4IN1Z-1,GO CONTROL; P/N: 10012103 X4; INK: BLACK; MATERIAL: 20# MEAD BOND; SIZE: 8.500” x 11.000”; TOLERANCE ± .125”; SCALE: 1-1
M4IN1Z-1
Wireless Multi-Function Sensor
360° PIR, Temp, Humidity and Light Sensor
NOTE: This unit must be added to the Network only where it will be permanently installed. The proper operation of this node in the
mesh network is dependent on it knowing its location with respect to other nodes. You cannot “test bench” configure this unit, then install.
GOCONTROL MINI 4IN1
•
•
•
•
•
•
The GoControl™ family of Z-Wave® certified wireless Lighting Products (smart
LED fixtures, bulbs, switches, dimmers, outlets and plug-in modules) Control
Products (thermostats, irrigation controller and garage door controller) and
Sensors (flood, leak, alert sounder, motion sensor and door/window sensor)
bring a new level of intelligent wireless Home Automation capability to
commercial and residential environments.
The Z-Wave wireless protocol is an international wireless standard for remote
home automation, security and other applications. This product can be included
and operated in any Z-Wave network with other Z-Wave certified devices
from other manufacturers and/or other applications. All non-battery operated
nodes within the network will act as repeaters regardless of vendor to increase
reliability of the network.
The M4IN1Z-1 Smart Multifunction Sensor is simple to set up and combines 4
popular functions in a small battery powered footprint: 360° PIR, Temperature,
Humidity and Light Sensors.
GoControl Z-Wave products are easy to install, are Z-Wave Plus certified, and
allow dealers to create an integrated wireless network with nearly limitless
expansion and interoperability with security, energy management, home
entertainment, appliances, and more
Send an alert if motion is sensed.
Provide the absolute temperature.
Provide the humidity level.
Send an alert when light is present.
Add or Remove Mini 4in1.
Over-the-air firmware update by the gateway or static Controller.
INSTALLATION
The M4IN1Z-1 can be mounted on a wall or ceiling using the double stick tape
(included). It can also be placed on a table top.
1. Remove the rear cover by pushing button on sensor top.
PUSH BUTTON
REMOVE REAR COVER
SENSOR TOP
Figure 2. Removing Rear Cover of Mini 4in1 Sensor
LIGHT SENSOR
2. Insert 2 AAA batteries (included). The LED will briefly illuminate in RED,
AAA BATTERIES
PROGRAM SWITCH
SENSOR TOP
Figure 1. M4IN1Z-1 Mini 4in1 Sensor Components
Figure 3. Install Batteries into Sensor Top
BLUE, then GREEN.
3. Replace the rear cover onto the sensor top.
4. Install in permanent location using provided double stick tape. The
M4IN1Z-1 should be mounted (6) six feet from the floor.
5. Press the program switch. The Walk Test LED will flash 5 times if the sensor
has not been “included” in a Z-Wave network. If the LED flashes once, the
sensor has been already been “included”.
Z-WAVE PLUS FEATURES
The M4IN1Z-1 contains a Z-Wave 500 Series Module that supports Z-Wave
Plus® features. A Z-Wave certified portable or stationary Controller can
communicate with the Z-Wave 500 Series Module. Depending on the capability
of the Controller or gateway software, the following operations can be performed
by Mini 4in1. Refer to the Controller or gateway manual for details.
Temperature:
If the present temperature is different than previously recorded and has
changed by more than the value in Parameter 2 (see below), the sensor will
report the present temperature to the hub. The LED will flash every (3) three
minutes to represent the temperature.
DETECTING AREA: UNIT: METER
TOP VIEW
SIDE VIEW
CEILING
5M
Temperature
LED Color
Under 59°F
Green
60 - 73° F
Blue
74 - 82° F
Yellow / Yellow
Green
Figure 4.Detecting Area
83 - 97° F
Purple
Z-WAVE PROGRAMMING
Over 97° F
Red
0M
9M
6 5 4 3 2 1 0 1 2 3 4 5 6M
Adding to a Network
Refer to your Controller operating instructions to add this switch under the
command of the Wireless Controller
1. With your Controller in Discovery or Add Mode, press the Program Switch
for 1 (one) second. The Yellow LED will blink. The device will appear in the
list of devices and should display as (4) four items: M4IN1Z-1 (Motion),
Light Sensor, Temperature Sensor and Humidity Sensor.
If the Controller/Gateway shows the addition failed, repeat Steps 1-3.
✓ NOTE: If you have trouble adding the M4IN1Z-1 to a group it may be that
the Home ID and Node ID were not cleared from it after testing. You must
first “RESET UNIT” to remove it from the network. Although adding it to a
group includes it in the network, removing it from a group does not remove
it from the network. “RESET UNIT” removes it completely from the network.
To Reset Unit (if required):
In the event that your primary Controller is lost or otherwise inoperable, to reset
the M4IN1Z-1 and clear all network information, follow these steps:
1. Remove cover to trigger the tamper switch. The LED will flash once and
send out Alarm Report.
2. Press Program Switch 10 times within 10 seconds. The M4IN1Z-1 will send
the “Device Reset Locally Notification” command and reset to the factory
default. (Remark: This is to be used only in the case of primary controller
being inoperable or otherwise unavailable).
3. The M4IN1Z-1 will completely reset to factory defaults.
Removing from a Network:
The M4IN1Z-1 can be removed from the network by the Controller/Gateway.
Refer to the Controller operating instructions for details. Be sure to select the
M4IN1Z-1 (PIR) to remove as the other Sensors are tied to this main device.
1. With your Controller in Remove Mode, press the Program Switch for one
(1) second.
2. You should see an indication on your Controller that the device was removed
from the network.
Association
1. Press the program switch on the M4IN1Z-1 to initiate the “Awake” mode.
The LED will flash once.
2. Put your Controller into “Association,” and following its instruction to
associate the M4IN1A-1 to other devices.
Other Z-Wave Commands
Auto Wake Up:
Use “Wake Up” command to set up the awaking time (from 10 minutes to 1
week) and send the wake up notification to the controller.
Battery Capacity Detection:
• Use “Battery Get” command to have the battery capacity back in %.
• It will detect the battery capacity automatically.
• Low Battery Auto Report when power is lower than 2.6V +/-0.1V.
Multilevel Sensor Report
Sensor Type
0x01
Scale
0x00 (°C)
0x01 (°F)
Size and Precision
Humidity Report:
If the present humidity is different than previously recorded and has changed
by more than the value in Parameter 3(see below), the sensor will report the
present illumination.
Light Report:
If the present illumination is different than previously recorded and has changed
by more than the value in Parameter 4 (see below), the sensor will report the
present illumination.
Multilevel Sensor Report
Sensor Type
0x03
Scale
0x00
(%)
Size and Precision
OPERATION
• When a person walks in from of M4IN1Z-1, the sensor will send Basic set
On (0xFF) and the Red LED will flash once. Refer to status report as table
below.
• In no movement is detected in (3) three minutes (default), it will send Basic
Set OFF (0x00) will be sent and the Red LED will flash once.
• The M4IN1Z-1 is equipped with tamper switch. If the tamper switch is
triggered ( or the cover is removed), the M4IN1Z-1 will send an Alarm
Report.
• If the tamper switch is closed (or the cover closed), the M4IN1Z-1 will send
an Alarm Report.
• Supports OTA Firmware update from the controller. Please refer to your
controller manual and use COMMAND_CLASS_FIRMWARE_UPDATE_
MD_V2. To proceed with the OTA process. Once the OTA function is
successful, make sure to exclude the device and include again before using
the device.
Alarm V1
Movement &
Tamper Switch
Alarm Type
0x07
Alarm Level
0x00 (No
movement after
3 min.) 0xFF
(Motion detected)
Notification V4
(Movement)
Notification Type
0x07
0x07
Notification Event
0x08 (Motion
detected)
0x00 (No
movement after
3 min.)
0x03 (Cover
removed)
0x00 (Cover
closed)
0x08 (Motion
detected) 0x00
(No movement
after 3 min.)
0x03
Notification Event
Parameter
LED Mode
Notification V4
(Tamper Switch)
1 bit
Parameter
Value
0x00
°F
0x01
1 (1°C)
Parameter
Size
Value
Default
1 bit
1 - 50 (Setup from
1% - 50%)
10%
Parameter
Size
Value
Default
1 bit
0.5 - 50 (Setup
from 0 for OFF or
5% - 50%)
10%
The M4IN1Z-1is certified to comply with applicable FCC and IC rules and
regulations governing RF and EMI emissions.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) This device must accept any interference received, including
interference that may cause undesired operation.
FCC Notice
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions may cause
harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected
• Consult the dealer or an experienced radio/TV technician to help.
• Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment
Humidity
Light
Motion Sensor
Size
Value
1 bit
1 - 255 (unsigned
decimal) Minutes
(default: 3 minutes)
Parameter
Size
Value
1 bit
1-7
(default: 4)
1 - 3 (Mode 1 - Mode 3)
Mode 1➜LED Turn Off
(Both Temp / PIR Trigger)
Mode 2 ➜ (Breathing
Light Mode) PIR (Quick
Flash)
Mode 3 ➜ LED Quick
Flash (Temp / PIR Trigger)
REGULATORY INFORMATION
1 - 50 (Setup from
0.1° C - 5° C
Parameter
1 bit
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
°C (0x00)
1 bit
Z-WAVE COMMAND CLASSES
Default
0°C
Value
Power: 2 - AAA battery (Included)
Signal (Frequency): 908.42 MHz / 916 MHz
Range: Up to 130 feet line of sight
The M4IN1Z-1 supports the Configuration command. Each unit can be
configured to operate slightly differently that how it works when it is first
installed.
Using the Configuration command , the following can be configured:
Temperature
The reporting temperature parameters can be set to the consumer’s specific
needs, changing from Celsius (default) to FaHrenheit and the reporting
threshold (default 1° C)
Size
Size
SPECIFICATIONS
CONFIGURATION
Parameter
Parameter
(Parameter 5) Re-trigger duration: User can change value from 1 to 255
minutes to setup the re-trigger time when there is no movement detected in the
period of time. Default is 3 minutes.
(Parameter 6) Infrared sensor sensitivity adjustment, 7 levels sensitivity, 1=
most sensitive, 7 = most insensitive, default values = 4.
IC Notice
This Class B digital apparatus complies with Canadian ICES-003
Cet appareil numérique de la classe B est conforme à la norme NMB-003
du Canada. Le présent appareil est conforme aux CNR d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation est autorisée
aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage,
et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d’en compromettre le fonctionnement.
This device complies with the Industry Canada license exempt RSS
standard(s). Operation is subject to the following two conditions: (1) this device
may not cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
Limitations
THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, SHALL NOT EXCEED THE WARRANTY PERIOD PROVIDED
HEREIN.
Some states do not allow limitations on how long an implied warranty lasts, so
the above limitation may not apply to you.
NS&C SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL
DAMAGES RESULTING FROM THE BREACH OF ANY WRITTEN OR
IMPLIED WARRANTY.
Some states do not allow the exclusion of limitation or consequential damages,
so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other legal
rights which vary from State to State.
Important !!!
Radio controls provide a reliable communications link and fi ll an important
need in portable wireless signaling.
However, there are some limitations which must be observed.
• For U.S. installations only: The radios are required to comply with FCC
Rules and Regulations as Part 15 devices.
• As such, they have limited transmitter power and therefore limited range.
• A receiver cannot respond to more than one transmitted signal at a time
and may be blocked by radio signals that occur on or near their operating
frequencies, regardless of code settings.
• Changes or modifications to the device may void FCC compliance.
• Infrequently used radio links should be tested regularly to protect against
undetected interference or fault.
• A general knowledge of radio and its vagaries should be gained prior
to acting as a wholesale distributor or dealer, and these facts should be
communicated to the ultimate users
NOTICES
Z-Wave® and Z-Wave Plus® are registered trademarks of Sigma Designs and
its subsidiaries in the United States and other countries.
WARRANTY
What is Covered?
Nortek Security & Control (“NS&C”) warrants to consumers who
purchase this product for personal, family or household purposes
new from NS&C directly or from an authorized NS&C dealer, that the
product will be free from defects in materials and workmanship for a
period of (1) year from the date of purchase. This warranty only applies
if the product is installed at a residence in the 50 United States or
District of Columbia, and only at the site of the original installation. It is
not transferable. This warranty is not extended to resellers.
If a defect exists, NS&C will have you ship the defective part or product
to us and we will, at our option, either repair or replace it. This warranty
does not cover the cost of labor to remove a defective part or product
or to reinstall any repaired or replacement part.
This warranty does not cover defects or damages caused by improper
handling, maintenance, storage, installation, removal or re-installation,
misuse, non-factory authorized modification or alteration, use of
incompatible accessories, electrical power problems or surges, impact
by foreign objects, accident, fire, acts of God, normal wear and tear
or shipping damage other than a shipment from NS&C. Note that all
NS&C products are designed to be installed, removed and serviced by
trained individuals or professionals.
Keep your original sales receipt as it will be required to obtain warranty
service.
This warranty shall not be extended or restarted upon receipt of any
repaired or replacement part or product under this warranty. No person
is authorized to extend or otherwise modify this warranty.
How do I Obtain Warranty Service?
To obtain warranty service, email our Returns Department at returns@nortek.
com. Include your name, address, telephone number, the model number of
your product, a copy of your original sales receipt, and a description of the
problem. Unless we need to discuss the situation further with you, you will be
emailed a Return Authorization Number and shipping instructions. If we need
to discuss the situation further with you, we will call or email you. NS&C may
require troubleshooting on installed product before a Return Authorization
Number is issued. Anything shipped to us without a Return Authorization
Number will be automatically returned unopened. You are responsible for the
charges for shipment to us, unless you are a California resident
Copyright © 2016 Nortek Security & Control LLC
10012103X4

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2016:05:24 10:05:34-07:00
Create Date                     : 2016:05:24 10:04:46-07:00
Metadata Date                   : 2016:05:24 10:05:34-07:00
Format                          : application/pdf
Title                           : 10012103X4M4IN1Z-1 Instructions.indd
Creator                         : Copyright © 2016 Nortek Security & Control
Producer                        : Acrobat Distiller 10.1.16 (Windows)
Keywords                        : 
Document ID                     : uuid:46c426c0-6675-4d89-9c99-ac9ad1d094b3
Instance ID                     : uuid:f104ed59-a307-4a9b-bd71-dc9812f45c03
Startup Profile                 : Print
Page Count                      : 4
Author                          : Copyright © 2016 Nortek Security & Control
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools
FCC ID Filing: EF4-00144

Navigation menu