Nortek Security and Control 00148 500 Series Z-wave Wall Switch User Manual 10007259A WS15Z5 1 Instructions indd

Nortek Security & Control LLC 500 Series Z-wave Wall Switch 10007259A WS15Z5 1 Instructions indd

Users Manual

Download: Nortek Security and Control 00148 500 Series Z-wave Wall Switch User Manual 10007259A WS15Z5 1 Instructions indd
Mirror Download [FCC.gov]Nortek Security and Control 00148 500 Series Z-wave Wall Switch User Manual 10007259A WS15Z5 1 Instructions indd
Document ID3344691
Application IDwWIo8HtfS9BtDqFLtTXBdg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize30.26kB (378275 bits)
Date Submitted2017-04-04 00:00:00
Date Available2017-04-04 00:00:00
Creation Date2016-10-17 15:24:18
Producing SoftwareAcrobat Distiller 10.1.16 (Windows)
Document Lastmod2016-10-17 15:24:47
Document Title10007259A WS15Z5-1 Instructions.indd
Document CreatorPScript5.dll Version 5.2.2
Document Author: Copyright © 2016 Nortek Security & Control

PRINTER’S INSTRUCTIONS:
INSTR,INSTL,WS15Z5-1; P/N: 10007259 A; INK: BLACK; MATERIAL: 20# MEAD BOND; SIZE: 8.500” x 11.000”; TOLERANCE ± .125”; SCALE: 1-1;
WS15Z5-1
Z-Wave Radio Frequency (RF) Controlled, 120 VAC
Scene and NWI Capable, Wall Mount Switch, Series 500
WHITE
NEUTRAL
120 VAC
LINE
BLUE
BLACK
SCORED TAB WILL
BREAK FLUSH WITH
EDGE OF PLASTIC
LOAD
15 AMPS
MAXIMUM
PUSH ON
WS15Z5-1 AND THE LOAD
MUST SHARE THE SAME
PROPRIETARY NEUTRAL
PUSH OFF
Shown with supplied
decorative trim plate
TAP TOP OR BOTTOM
OF SWITCH PADDLE
TO CONFIGURE
GREEN GROUND
STATUS LED
NOTE: This unit must be added to the Network only where it will be permanently installed. The proper operation of this node in the
mesh network is dependent on it knowing its location with respect to other nodes. You cannot “test bench” configure this unit, then install.
WS15Z5-1 WALL MOUNT SWITCH
INSTALLATION
The GoControl™ family of Z-Wave® certified wireless Lighting Products (smart LED
fixtures, bulbs, switches, dimmers, outlets and plug-in modules) Control Products
(thermostats, irrigation controller and garage door controller) and Sensors (flood, leak,
alert sounder, motion sensor and door/window sensor) bring a new level of intelligent
wireless Home Automation capability to commercial and residential environments.
The Z-Wave wireless protocol is an international wireless standard for remote home
automation, security and other applications. This product can be included and
operated in any Z-Wave network with other Z-Wave certified devices from other
manufacturers and/or other applications. All non-battery operated nodes within the
network will act as repeaters regardless of vendor to increase reliability of the network.
The WS15Z5-1 Wall Mount Switch allows remote ON/OFF control of loads
connected to the switch, and is easily wired in place of a standard wall switch.
GoControl Z-Wave products are easy to install, are Z-Wave certified, and allow
dealers to create an integrated wireless network with nearly limitless expansion
and interoperability with security, energy management, home entertainment,
appliances, and more.
DANGER! SHOCK HAZARD. Read and understand these instructions before
installing. This device is intended for installation in accordance with the National
Electric code and local regulations in the United States, or the Canadian Electrical
Code and local regulations in Canada. It is recommended that a qualified electrician
perform this installation. Make sure the load controlled by the switch does not
exceed 1800 watts. For indoor use only. Retain instructions for future use.
Wire this switch in place of a current wall switch according to the diagram above.
When used, WS15Z5-1’s are required to be wired to the same line (or neutral)
which is also wired to the load being controlled, and not wired to any other neutral.
If multiple neutrals are tied together in one box, separate the neutrals to preserve
the integrity of the WS15Z5-1 circuit.
✓ CAUTION! Do not wire unit “live” (with power on the circuit).
Adding to a network:
Refer to your Controller operating instructions to add this switch under the command
of the Wireless Controller.
1. With your Controller in Discovery or Add Mode, tap the switch. The LED will blink
slowly when in ADD Mode.
2. You should see an indication on your Controller that the “device was added” to
the network and the LED will stop blinking.
3. The device will appear in the list of Switches. It should display as a switch.
If the Controller/Gateway shows the addition failed, repeat Steps 1-3.
✓ NOTE: If you have trouble adding the WS15Z5-1 to a group it may be that
the Home ID and Node ID were not cleared from it after testing. You must first
“RESET UNIT” to remove it from the network. Although adding it to a group
includes it in the network, removing it from a group does not remove it from
the network. If removed from a group, it functions as a repeater (only). “RESET
UNIT” removes it completely from the network.
To Reset Unit (If Required):
Z-WAVE PLUS FEATURES
In the event that your primary Controller is lost or otherwise inoperable, to reset the
WS15Z5-1 and clear all network information, follow these steps:
1. Tap the top of the switch five (5) times.
2. Press and hold the bottom of the switch for 15 seconds. The LED will increasingly
blink faster to indicate that a Reset is taking place.
The WS15Z5-1 contains a Z-Wave 500 Series Module that supports Z-Wave Plus®
features. A Z-Wave certified portable or stationary Controller can communicate with
the Z-Wave 500 Series Module.
Depending on the capability of the Controller or gateway software, the following
operations can be performed with the WS15Z5-1. Refer to the Controller or gateway
manual for details.
Removing from a network:
The WS15Z5-1 can be removed from the network by the Controller/Gateway. Refer
to the Controller operating instructions for details.
1. Set the Controller into Removal Mode and follow its instruction to delete the
WS15Z5-1 from the Controller.
2. Remove the switch by tapping the paddle 2 times. The LED will begin blinking
slowly for 10 seconds indicating that it has been removed.
3. You should see an indication on your Controller that the “device was removed”
from the network.
• Turn the load ON and OFF.
• Add or Remove the WS15Z5-1.
• Assign the WS15Z5-1 to a specific Group/Scene and/or to include the load as part of
ALL ON or ALL OFF system commands.
• Over-the-air firmware update by the gateway or static Controller.
• Lifeline function which automatically notifies the associated modules and the network
that a manually reset device is no longer in the network, thus, the corresponding
association becomes invalid.
BASIC OPERATION
Paddle Presses
Scene
Number
Key Attribute
The switch paddle on the WS15Z5-1 allows the user to:
Press & Hold Top
• Turn the attached load on or off.
• Tapping top of switch turns the load attached ON.
• Tapping bottom of switch turns the load attached OFF.
Release Top
Single Tap Top
(Local Control)
LED Indication
To act as a night light, the LED on the WS15Z5-1 will turn ON when the load
attached is OFF. However, the LED can be user configured to turn ON, when the
load attached is ON, if so desired. See “CONFIGURATION” section.
Triple Tap Top
Press & Hold Bottom
Release Bottom
Single Tap Bottom
Remote Control
The WS15Z5-1 will respond to BASIC and BINARY commands that are part of the
Z-Wave system. Refer to your Controller’s instructions as to whether your Controller
can transmit those commands.
Associations
The GoControl WS15Z5-1 supports three (3) Association Groups. Group 1 is the
“Lifeline” group and must be assigned the Node ID of the Z-Wave
Controller to which unsolicited notifications from the WT00Z5-1 will be sent.
Group 1 supports a single Node ID. The Z-Wave Controller should set the
Lifeline Association automatically after inclusion. For instructions on how to set
Associations, please refer to your Z-Wave Controller instructions. Group 2 nodes
will be sent BASIC On/Off commands and is intended to control switches like the
GoControl WS15Z5. Group 3 nodes will be sent Multilevel Switch commands and is
intended to control dimmers like the GoControl WD500Z5. Groups 2 and 3 support
up to five (5) Node IDs.
Double Tap Top
Double Tap Bottom
Triple Tap Bottom
When the paddle is tapped or pressed, the dimmer sends the Scene Number and
Key Attribute to the Z-Wave Hub via Association Group 1. The hub can then control
any Z-Wave devices supported by the Hub. Refer to your Z-Wave Hub instructions
for details on how to control other devices using the Central Scene feature.
✓ NOTE: The Z-Wave Hub has to support the Central Scene Command Class in
order to take advantage of this feature.
✓ NOTE: The Scene Number is not the same as standard Z-Wave Scenes IDs.
The Scene Number is simply the top (1) or bottom (2) of the paddle and is not
a “Scene” in the classic Z-Wave sense. The Key Attribute tells the Hub how the
paddle was pressed as described in the table above.
Creating Associations
CONFIGURATION
1. Learn all devices into the Z-Wave Hub.
2. Tap the paddle of the WS15Z5-1 four times quickly to enter Association mode.
The LED will begin to blink quickly (twice per second).
3. Follow the instructions for inclusion or exclusion of the device to be associated.
For GoControl devices, tap the button one or two times.
4. Repeat Step #2 and #3 for up to 5 total dimmers and / or switches within 60
seconds of entering Association mode.
5. Association mode will turn off after 60 seconds or when a node has been
associated.
Although the Associations are now functional, it is recommended that you refer
to your Hubs instructions to “Heal” the Z-Wave network to recognize the new
Associations. Dimmers are automatically assigned to group 3 and other devices
are assigned to group 2.
The WS15Z5-1 supports the Configuration command. Each unit can be
configured to operate slightly differently than how it works when you first install it.
Using the Configuration command you can configure the following:
Night Light
By default, the LED on the WS15Z5-1 will turn OFF when the load attached is
turned ON. To make the LED turn ON when the load attached is turned ON, set
Parameter 3 to a value of 1.
Parameter Length Valid Values
Removing Associations
To remove the Associations, if the Hub has recognized the Associations, refer to
the Z-Wave Hub’s instructions on how to remove Associations. If the Hub has not
recognized the Associations, removing the WS15Z5-1 from the Z-Wave network will
eliminate the Associations.
1 Byte
Configuration Option
LED OFF when the load is on, and ON when the load
is off (default - night lite mode)
LED ON when the load is on, and OFF when the
load is off
LED is always on
LED is always off
LED blinks during RF transmissions from or to the
device
Invert Switch
To change the top of the switch to OFF and the bottom of the switch ON, set
Parameter 4 to a value of 1.
ADVANCED OPERATION
All On/All Off
Parameter Length Valid Values
Configuration Option
Top of switch is ON, bottom of switch is OFF (default)
1 Byte
Bottom of switch is ON, top of switch is OFF
The WS15Z5-1 supports the ALL ON / ALL OFF commands. The WS15Z5-1 can be
set to respond to ALL ON and ALL OFF commands four different ways.
Refer to your Controller for information on how to set the WS15Z5-1 to operate in
the manner you desire. Some Controllers may be only able to set certain settings of
ALL ON/ALL OFF response.
The four different ways the WS15Z5-1 can be setup to respond to ALL ON and ALL
OFF commands are:
1. Responds to ALL ON or the ALL OFF command.
2. Responds to ALL OFF command but will not respond to ALL ON command.
3. Responds to ALL ON command but will not respond to ALL OFF command.
4. Responds to ALL ON and the ALL OFF command.
Over-The-Air (OTA) Update
A Quadruple tap of the switch enables the firmware update mode. Firmware update
mode must be entered before the system Controller sends the firmware update
command to begin downloading new firmware. Firmware update mode is enabled
for 60 seconds after the quadruple tap. If the Firmware update does not begin
before the end of the 60 seconds then firmware update mode is exited returns
to normal operation. The LED “winks” twice per second indicating it is in firmware
update mode.
Resetting to Defaults
New Central Scene Command Class Support
Each configuration Parameter can be set back to its default setting by setting the
default bit in the Configuration Set command. See your Controller’s instructions on
how to do this (and if it supports it). All configuration commands will be reset to their
default state when the WS15Z5-1 is excluded from the Z-Wave network by using
the Controller to reset the node.
The GoControl Dimmer Switch supports the new Central Scene Command Class.
This allows the Switch to execute up to 10 independent events that are triggered by
Key Attributes related to (2) two Scene Numbers.
By tapping or holding down the top or bottom of the Switch paddle a specific Scene
Number Key Attribute is transmitted as shown below in addition to the standard
operation of the switch as described above in Basic Operations Load Control
section.
SPECIFICATIONS
Power:
Signal (Frequency):
Maximum Load:
Range:
WARRANTY
120 VAC, 60 Hz
908.42 MHz / 916 MHz
Resistive: 15 amps (1800 watts) maximum, 120 VAC
Motor: 1/2 H.P. maximum, 120 VAC
Incandescent: 600W maximum, 120 VAC
Up to 130 feet line of sight
What is Covered?
Nortek Security & Control (“NS&C”) warrants to consumers who purchase this product for
personal, family or household purposes new from NS&C directly or from an authorized
NS&C dealer, that the product will be free from defects in materials and workmanship for
a period of (1) year from the date of purchase. This warranty only applies if the product is
installed at a residence in the 50 United States or District of Columbia, and only at the site
of the original installation. It is not transferable. This warranty is not extended to resellers.
If a defect exists, NS&C will have you ship the defective part or product to us and we will,
at our option, either repair or replace it. This warranty does not cover the cost of labor to
remove a defective part or product or to reinstall any repaired or replacement part.
This warranty does not cover defects or damages caused by improper handling,
maintenance, storage, installation, removal or re-installation, misuse, non-factory
authorized modification or alteration, use of incompatible accessories, electrical power
problems or surges, impact by foreign objects, accident, fire, acts of God, normal wear
and tear or shipping damage other than a shipment from NS&C. Note that all NS&C
products are designed to be installed, removed and serviced by trained individuals or
professionals.
Keep your original sales receipt as it will be required to obtain warranty service.
This warranty shall not be extended or restarted upon receipt of any repaired or
replacement part or product under this warranty. No person is authorized to extend or
otherwise modify this warranty.
REGULATORY INFORMATION
The WS15Z5-1 is certified to comply with applicable FCC and IC rules and regulations governing RF and EMI emissions.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) This device must accept any interference received, including interference
that may cause undesired operation.
FCC Notice
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected
• Consult the dealer or an experienced radio/TV technician to help.
• Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment
How do I Obtain Warranty Service?
To obtain warranty service, email our Returns Department at returns@nortek.com.
Include your name, address, telephone number, the model number of your product, a
copy of your original sales receipt, and a description of the problem. Unless we need to
discuss the situation further with you, you will be emailed a Return Authorization Number
and shipping instructions. If we need to discuss the situation further with you, we will call
or email you. NS&C may require troubleshooting on installed product before a Return
Authorization Number is issued. Anything shipped to us without a Return Authorization
Number will be automatically returned unopened. You are responsible for the charges for
shipment to us, unless you are a California resident.
IC Notice
This Class B digital apparatus complies with Canadian ICES-003
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Le présent appareil est conforme
aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux
conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
This device complies with the Industry Canada license exempt RSS standard(s). Operation is subject to the following
two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
Limitations
THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXCEED THE WARRANTY PERIOD PROVIDED HEREIN.
NOTICES
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
NS&C SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE
BREACH OF ANY WRITTEN OR IMPLIED WARRANTY.
Z-Wave® and Z-Wave Plus® are registered trademarks of Sigma Designs and its subsidiaries in the United States
and other countries.
Some states do not allow the exclusion of limitation or consequential damages, so the above limitation or exclusion
may not apply to you.
This warranty gives you specific legal rights, and you may also have other legal
rights which vary from State to State.
IMPORTANT !!!
• Radio controls provide a reliable communications link and fill an important need
in portable wireless signaling. However, there are some limitations which must be
observed.
• For U.S. installations only: The radios are required to comply with FCC Rules and
Regulations as Part 15 devices. As such, they have limited transmitter power and
therefore limited range.
• A receiver cannot respond to more than one transmitted signal at a time and may be
blocked by radio signals that occur on or near their operating frequencies, regardless
of code settings.
• Changes or modifications to the device may void FCC compliance.
• Infrequently used radio links should be tested regularly to protect against undetected
interference or fault.
• A general knowledge of radio and its vagaries should be gained prior to acting as
a wholesale distributor or dealer, and these facts should be communicated to the
ultimate users.
Copyright © 2016 Nortek Security & Control LLC
10007259 A

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Create Date                     : 2016:10:17 15:24:18-07:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2016:10:17 15:24:47-07:00
Metadata Date                   : 2016:10:17 15:24:47-07:00
Producer                        : Acrobat Distiller 10.1.16 (Windows)
Keywords                        : 
Format                          : application/pdf
Title                           : 10007259A WS15Z5-1 Instructions.indd
Creator                         : Copyright © 2016 Nortek Security & Control
Document ID                     : uuid:0981af55-542e-46f2-ba4e-83fcdc952810
Instance ID                     : uuid:8d232e48-f58c-4b9e-ba76-8b13407acaea
Startup Profile                 : Print
Page Count                      : 4
Author                          : Copyright © 2016 Nortek Security & Control
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools
FCC ID Filing: EF400148

Navigation menu