Welcome to your
ADT Smoke Alarm
1
1.
Setup
Take the ADT Smoke Alarm to where you intend
to mount it after setup.
•
•
Setup
3. Remove the tab on the smoke alarm marked “Pull This
Tab”. The red LED will blink once followed by a single
blink of the yellow LED.
Make sure you are within 350 feet from the
ADT Security Hub. (Exact range depends on your
home’s construction, environment, position of the
ADT Security Hub, and the position and number of
other connected devices.)
Make sure that your ADT Security Hub is disarmed
before connecting a new device.
2. Use the SmartThings app on your smartphone to select the “My Home” tab. Select "Things", and then “Add
a Thing".
Smoke Alarm (Back)
Battery Tab
2
Setup
4. Use the SmartThings app to scan the QR code on
the back of the alarm and then follow the on-screen
instructions to complete setup.
Smoke Alarm (Back)
QR Code
5. Remove the QR code from the back of the alarm and
attach it to this guide for future reference.
Placement
Install the ADT Smoke Alarm in a place where the alarm
can be heard easily. Ideally, per the National Fire Alarm
Code (NFPA Standard 72), a smoke alarm should be
installed:
•
In all sleeping rooms and guest rooms.
•
Outside of each separate dwelling unit sleeping
area within 21 feet of any door to a sleeping room,
the distance measured along a path of travel.
•
On every level of a dwelling unit, including
basements.
Placement
•
On every level of a residential board and care
occupancy (small facility), including basements and
excluding crawl spaces and unfinished attics.
•
In the living area(s) of a guest suite.
•
In the living area(s) of a residential board and care
occupancy (small facility).*
THIS EQUIPMENT SHOULD BE INSTALLED IN
ACCORDANCE WITH THE NATIONAL FIRE PROTECTION
ASSOCIATION’S STANDARD 72.**
(Reprinted with permission from NFPA 72®, National Fire Alarm Code
Copyright © 2007 National Fire Protection Association, Quincy, MA 02269.
This reprinted material is not the complete and official position of the
National Fire Protection Association, on the referenced subject which is
represented only by the standard in its entirety.)
**
(National Fire Alarm Code® and NFPA 72® are registered trademarks of the
National Fire Protection Association, Inc., Quincy, MA 02269.)
Placement
The required number of smoke alarms might not
provide reliable early warning protection for those
areas separated by a door from the areas protected
by the required smoke alarms.
For this reason, it is recommended that the householder
consider the use of additional smoke alarms for those
areas for increased protection. The additional areas
include the basement, bedrooms, dining room, furnace
room, utility room, and hallways not protected by the
required smoke alarms.
The installation of smoke alarms in kitchens, attics
(finished or unfinished), or garages is not normally
recommended, as these locations occasionally
experience conditions that can result in improper
operation.
Placement
Important: Specific requirements for smoke alarm
installation vary from state to state and from region to
region. Check with your local Fire Department for current
requirements in your area.
Sufficient smoke must enter your smoke alarm before it
will respond. Your smoke alarm needs to be within 21 feet
of the fire to respond quickly. Smoke alarms also need to
be in positions where they can be heard throughout the
property, so they can wake you and your family in time for
everyone to escape.
A single smoke alarm will give some protection if it is
properly installed, but most homes will require two or
more to ensure that a reliable early warning is given. For
recommended protection you should put individual smoke
alarms in all rooms where fire is most likely to break out
(apart from the kitchen and bathroom, where they should
Placement
be placed nearby). Your first smoke alarm should be
located between the sleeping area and the most likely
sources of fire (living room for example), but it should
not be more than 21 feet from the door to any room where
a fire may start and block your escape from the house.
Single-Story Dwellings: If the premises is one story, you
should put your first smoke alarm in a corridor or hallway
between the sleeping and living areas. Place it as near to
the living area as possible, but make sure that it can be
heard loudly enough in the bedroom to wake someone.
In houses with more than one sleeping area, smoke
alarms should be placed between each sleeping area
and the living area.
Placement
Placement
Multiple-Story Dwellings: If your home has more than
one floor, at least one smoke alarm should be fitted on
each level. Suggested locations shown below:
Hallway
Attic
Bedroom
Kitchen
Basement
Master Bedroom
Family Room
Garage
Recommended Protection: Fire authorities recommend
you put individual smoke alarm in or near all rooms where
fire is most likely to break out (apart from the locations
to avoid e.g. bathrooms).
The living room is the most likely place for a fire to start at
night, followed by the kitchen and then the dining room.
Consideration should be given to installing smoke alarms
in any bedrooms where fires might occur, for instance,
where there is an electrical appliance such as an electric
blanket or heater, or where the occupant is a smoker.
In addition, consideration should be also given to installing smoke alarms in any rooms where the occupant is
unable to respond very well to a fire starting in that room,
such as an elderly or sick person or a very young child.
This device shall not be used with a detector guard.
Placement
Placement
For Ceiling Mounting:
For Wall Mounting:
Hot smoke rises and spreads out, so a central ceiling
position is the recommended location. The air is “dead”
and does not move in corners, therefore smoke alarms
must be mounted away from corners. Keep at least 12
inches from walls and corners. Additionally, mount the
unit at least 12 inches from any light fitting or decorative
object which might prevent smoke entering the smoke
alarm. Do not attach the detector to removable ceiling
panels.
If ceiling mounting is impractical, smoke alarms may
be mounted on a wall (if local ordinances permit),
provided that:
Not this area
4 Inches (10cm)
Anywhere in this area
3 Feet
(0.9m)
3 Feet
(0.9m)
•
The top of the detection element is between 6 inches
and 12 inches below the ceiling.
•
The bottom of the detection element is above the
level of any door openings.
Wall mounting should only be considered where close
spaced beams or similar obstructions may preclude
ceiling mounting. It is considered to be the responsibility
of the installer or homeowner to determine if the
presence of asbestos in the ceiling material would make
ceiling mounting impractical.
3
Placement
On a sloping or peaked ceiling, install a smoke alarm
within 24 inches of the peak (measured vertically). If this
height is less than 24 inches the ceiling is regarded as
being flat.
Smoke Alarms should face out in this position:
1.
Mounting
Install the mounting base using the two screws and
anchors provided.
Ceiling Mount
12 inches
from wall
12 inches
from wall
Smoke Alarm (front)
Mounting Plate
Wall behind alarm
Smoke Alarm
Mounting
Mounting
12 inches
from ceiling
12 inches
from wall
2. Fit the alarm inside the base by aligning it over the
base, then turn the alarm in a clockwise direction until
it clicks into place.
Mounting Plate
Alignment Marks
Wall Mount
Smoke Alarm
Mounting Plate
Push up and turn clockwise
Smoke Alarm
3. Test the alarm after completing the installation
(see following section for details).
Mounting
WARNING: please read carefully and thoroughly.
•
•
NFPA 72 states: Fire-warning equipment for
residential occupancies are capable of protecting
about half of the occupants in potentially fatal fires.
Victims are often intimate with the fire, too old or
too young, or physically or mentally impaired such
that they cannot escape even when warned early
enough that escape should be possible. For these
people, other strategies such as protection-in-place
or assisted escape or rescue would be necessary.
Although smoke alarms can help save lives by
providing an early warning of a fire, they are not a
substitute for an insurance policy. Homeowners and
renters should have adequate insurance to protect
their properties.
Mounting
•
A battery powered alarm must have a battery of
the specified type, in good condition and installed
properly.
•
Smoke alarms cannot provide an alarm if smoke does
not reach the detector. Therefore, smoke alarms may
not sense fires starting in chimneys, walls, on roofs,
on the other side of a closed door or on a different
floor.
•
Studies have shown that smoke and heat alarms may
not awaken all sleeping individuals, and that it is the
responsibility of individuals in the household that are
capable of assisting others to provide assistance to
those who may not be awakened by the alarm sound
or those who may be incapable of safely evacuating
the area unassisted.
Mounting
•
•
•
Mounting
The use of alcohol or drugs may also impair one's
ability to hear the smoke alarm. For maximum
protection, a smoke alarm should be installed in
each sleeping area on every level of a home.
•
Smoke alarms must be tested regularly to make
sure the batteries and the alarm circuits are in good
operating condition.
•
Practice using different ways out.
•
Make a home escape plan. Draw a map of your home
showing all doors and windows. Discuss the plan with
everyone in your home.
•
Know at least two ways out of every room, if possible.
Make sure all doors and windows leading outside
open easily.
•
Practice your home fire drill at night and during the
day with everyone in your home, twice a year.
Family Escape Plan: According to National Fire
Protection Association (NFPA) there often is very
little time between the detection of a fire and the
time it becomes deadly. This interval can be as
little as 1 or 2 minutes. Planning and practicing
for fire conditions with a focus on rapid exit from
the residence are important. Drills should be held
so that all family members know the action to be
taken.
If the alarm is located outside the sleeping room or on
a different floor, it may not wake up a sound sleeper.
Safety Tips:
Mounting
•
Have an outside meeting place (like a tree, light pole,
or mailbox) a safe distance from the home where
everyone should meet.
•
Teach children how to escape on their own in case you
can't help them.
•
Close doors behind you as you leave.
Testing
Test the ADT Smoke Alarm after installation and then on
a weekly basis.
Note: If you have an ADT professional monitoring
service activated, make sure that your ADT Security Hub
is in Test Mode to avoid triggering a false alarm. See the
ADT Security Hub User Guide for more details.
Smoke Test: Hold a match or other smoldering stick near
the alarm with caution and gently blow smoke through
the alarm until it goes off.
Direct Heat Test: Direct heat toward the alarm, using a
hair dryer. Be sure to hold the heat source about 12 inches
from the alarm to avoid damaging the plastic. The alarm
will reset once it cools down.
Testing
Testing
Alarm Operation Test: Push and hold the Test button
on the alarm for a minimum of 5 seconds. The alarm
will sound, and the red LED blink. The ADT Security
Hub will display an alert for the smoke alarm.
If the alarm fails to activate with any of these tests, clean
it and repeat the tests. If cleaning does not restore the
alarm to normal operation, it should be replaced. Check
the date when the alarm should be replaced which is
given on the sidewall of the alarm.
YOUR ALARM SHOULD BE CLEANED AT LEAST ONCE
A YEAR.
Flashing Red LED
To clean your alarm, remove it from the mounting base.
You can clean the interior by using compressed air or
a vacuum cleaner hose to blow or vacuum through the
openings. The outside can be wiped with a dry cloth. After
cleaning, reinstall and test your alarm as described above.
Press and hold until alarm sounds
5
Troubleshooting
If the alarm emits 2 short beeps with the yellow LED
blinking twice every 48 seconds, it indicates an issue
with the alarm, which must then be replaced.
To silence the beeps and stop the yellow LED flashes,
you can press the test button and repeat as required, but
after 4 hours your alarm will no longer be supervised by
the security system.
If the alarm sounds without any apparent smoke being
present, press the test button to silence the alarm for 10
minutes. If the alarm sounds again, it may be dirty.
Pressing the test button again, within 4 minutes of the
alarm resounding, will get the alarm to re-calibrate. If
the alarm sounds again, follow the cleaning procedure
described above.
Replacing Batteries
The alarm regularly checks for low batteries, and will alert
you if a low battery is detected. The alarm will also beep
and the yellow LED flash to warn you the batteries must
be replaced.
Pressing the hush button will silence the beep and
the flashing yellow LED for 12 hours, if no other trouble
conditions exist.
WARNING: Use only batteries specified. Use of different
batteries may have a detrimental effect on the smoke
alarm. Removal of the batteries will render this alarm
inoperative.
1.
Remove the alarm from the mounting base by
twisting it counterclockwise.
Using your
Replacing Batteries
2. Remove the old batteries and wait a minimum of 20
seconds before installing 2 new CR123A batteries. Be
sure to install the battery correctly.
CR123A Batteries
Alarm (Back)
3.
Attach the alarm onto the mounting base by
matching up the alignment marks and then turning
the alarm clockwise until it clicks into place.
4. Wait for a single blink of the red LED, followed by a
single blink of the yellow LED. The alarm is now in
Standby mode.
ADT Smoke Alarm
7
Use
Use
What You Hear / See
What It Means
What To Do
Siren at full volume,
red LED flashing.
Sensing fire.
If safe, put out the source of the smoke. If unknown, get out of the house
immediately. Follow appropriate fire safety guidelines at all times.
No siren, red LED flash
every 8 seconds.
Smoke alarm hushed.
No action required.
1 beep plus yellow LED flash
every 48 seconds.
Batteries low.
Replace batteries.
2 beeps plus yellow LED flash
every 48 seconds.
Smoke and/or heat
sensor error.
Replace unit with same brand.
3 beeps plus yellow LED flash
every 48 seconds.
Product expired
(10 year typical life).
Replace unit with same brand.
8
Suggestions
The ADT Smoke Alarm monitors for smoke and extreme
temperatures in your home (heat above 135°F, or freeze
below 40°F).
When smoke or extreme temperatures are detected, the
loud local alarm sounds and a notification is sent to your
ADT Security Hub. Your ADT Security Hub can then send
an alert to your smartphone, automate connected devices,
or initiate optional ADT professional monitoring services
(additional fees apply).
There are many ways you can use an ADT Smoke Alarm
in your home:
•
Put one in your living room and set it to initiate
optional ADT professional monitoring service when
smoke is detected in your home (additional fees
apply).
Suggestions
•
Put one in your bedroom and set it to turn
on connected lights when smoke is detected.
•
Put one in your hallway and set it to turn off a
connected thermostat to avoid spreading smoke
through your home if a fire is detected.
•
Put one in your home and set a connected camera
to record video when smoke is detected (additional
fees may apply).
Note: To ensure proper functioning, all connected
devices must be configured correctly. This alarm is not
designed to be interconnected with other manufacturers'
products unless otherwise specified
Visit SmartThings.com/Welcome for more ideas, tips, and
special offers.
9
Works With SmartThings
SmartThings works with a wide range of connected
devices, including lights, cameras, locks, thermostats,
and sensors. It also works with the Google Assistant
and Amazon Alexa so you can control your smart home
with voice commands.
Look for the Works with SmartThings label next time
you’re buying a connected device for your home, or visit
SmartThings.com to see the full list of compatible
devices.
SmartThings, Inc., 665 Clyde Ave, Mountain View, CA 94043, USA. Information in this document
is subject to change without notice. Revised 05/17. Copyright 2017 SmartThings, Inc. All rights
reserved. ADT and the ADT logo are marks and/or registered marks of ADT. Unauthorized use
is strictly prohibited. CA ACO7155, 974443, PPO17232; FL EF0001121; LA F1639, F1640, F1643,
F1654; MA 172C; NC Licensed by the Alarm Systems Licensing Board of the State of North
Carolina, 7535P2, 7561P2, 7562P10, 7563P7, 7565P1, 7566P9, 7564P4; NY 12000305615; PA
090797; MS 15019511. P/N 10015711.
Risk of Noise Induced Hearing Loss: The ADT Security Hub is equipped with a warning siren.
Exposure to high sound levels or prolonged exposure to the warning siren can result in Noise
Induced Hearing Loss (NIHL).
Avoid installing the SmartThings Hub
near or inside sources of metal, radio
or electromagnetic interference.
Health, Safety and Regulatory Guide
WARNING: No user-serviceable parts inside. Refer all
servicing to qualified service personnel.
IMPORTANT CONSUMER INFORMATION: Please read
before activating or using the device.
WARNING: This product contains chemicals known to the State of
California to cause cancer and reproductive toxicity. For more information,
please call 1-800-SAMSUNG (726-7864).
Safety Instructions
•
•
•
•
•
Read, keep, and follow these instructions. Heed all warnings.
Clean only with a dry cloth.
Do not install near any heat sources such as radiators, heat registers, stoves, or other
apparatus (including amplifiers) that produce heat.
Only use attachments and accessories specified by the Manufacturer.
Read our Product Usage Guidelines at: www.SmartThings.com/Guidelines.
Safety Instructions: ADT Security Hub
Limitations of Alarm Products: This product should be tested periodically to make sure it is working
properly. The product, if used properly, may reduce the risk of burglary, robbery, and other adverse
events that have the potential to result in injury or loss of life; however, the manufacturer is not an
insurer. This product is neither insurance nor a guarantee that such an event will be prevented, and
users should protect themselves with proper insurance. The manufacturer makes no representation
that this product cannot be compromised or circumvented, that it will provide an adequate warning,
or that it will prevent any personal injuries, property damage, or other losses. Like any alarm
product, it may be bypassed, it is subject to compromise, and it may fail to warn for a variety
of reasons, including, but not limited to: 						
•
•
improper installation or positioning; improper maintenance; tampering; dead or improperly
installed batteries; sensing limitations; component failures; receivers;
intrusions may be outside of a product’s designated range and certain environmental
conditions may impact performance, and audible alarm signals may be outside of hearing
range, muted by doors, walls, and floors, unheard by deep sleepers or the hearing-impaired,
or overwhelmed by other sounds.
Safety Instructions: ADT Detectors
•
•
Do not expose products to moisture or extreme temperature.
Make sure that products are used in a dry location and within the recommended operating
temperature:
⸰⸰
⸰⸰
⸰⸰
⸰⸰
⸰⸰
⸰⸰
⸰⸰
•
•
ADT Security Hub: 32° to 120° F (0° to 49° C)
ADT Door and Window Detector: 32° to 120° F (0° to 49° C)
ADT Motion Detector: 32° to 120° F (0° to 49° C).
ADT Water Leak Detector: 32° to 104° F (0° to 40° C)
ADT Smoke Alarm: 32° to 100° F (0° to 40° C)
ADT Carbon Monoxide Alarm: 32° to 104° F (0° to 40° C)
ADT Keychain Remote: 32° to 120° F (0° to 49° C)
Make sure that the ADT Door and Window Detector is not positioned near metal or metallic
surfaces. Example: foil wallpaper.
The ADT Water Leak Detector is water resistant but not waterproof; avoid submerging it in water
or liquid to keep interior dry and to protect batteries. All other detectors should not be used
near water or exposed to dripping or splashing of any water or liquid.
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED
BATTERIES ACCORDING TO THE INSTRUCTIONS.
Disclaimer
Some content and services accessible through this device belong to third parties and are protected
by copyright, patent, trademark and/or other intellectual property laws. Such content and services
are provided solely for your personal non-commercial use.
You may not use any content or services in a manner that has not been authorised by the content
owner or service provider. Without limiting the foregoing, unless expressly authorised by the
applicable content owner or service provider, you may not modify, copy, republish, upload, post,
transmit, translate, sell, create derivative works, exploit, or distribute in any manner or medium any
content or services displayed through this device. 		
US Certifications
Certified under FCC Part 15.
ADT Security Hub
Manufacturer Model : F-ADT-HUB-1
FCC ID : EF400150
Battery Type: Shenzhen Grepow Battery CO
LTD, MFG P/N: GLP823990
ADT Door and Window Detector
Manufacturer Model : F-ADT-DW-1
FCC ID : EF400151
Battery Type: 1 x CR2450 (Panasonic)
ADT Motion Detector
Manufacturer Model : F-ADT-PIR-1
FCC ID : EF400152
Battery Type: 1 x CR123A (Panasonic)
ADT Smoke Alarm
Manufacturer Model : F-ADT-SMK-1
FCC ID : EF400153
Battery Type: 2 x CR123A (Panasonic)
Battery can be purchased at any
electronics store.
For each of the devices listed in the previous table, the following FCC statements
and information apply:
FCC Statement
This device complies with Part 15 of the FCC rules. Operation is subject to the
following conditions: (1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation.
FCC Caution
Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this equipment.
ADT Carbon Monoxide Alarm
Manufacturer Model : F-ADT-CO-1
FCC ID : EF400154
Battery Type: 2 x AAA / MN2400 (Duracell)
Battery can be purchased at any
electronics store.
ADT Keychain Remote
Manufacturer Model : F-ADT-KEY-1
FCC ID : EF400155
Battery Type: 1 x CR2450 (Panasonic)
ADT Water Leak Detector
Manufacturer Model : F-ADT-WTR-1
FCC ID : EF400156
Battery Type: CR123A
Visit SmartThings.com/Support-ADT
for instructions on battery replacement.
All specifications subject to change
without notice.
Important Note: FCC Radiation Exposure Statement
To satisfy FCC radiation exposure safety requirements for the ADT Security Hub, keep the device at
least 20cm from your body (excluding extremities: hands, wrists, feet, and ankles).
This ZigBee Certified Product works with
ZigBee networks supporting the Home
Automation Profile.
Global 2.4 GHz wireless use.
ZigBee® Certified is a registered trademark
of the ZigBee Alliance.
Information to the User
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation.
This equipment generates and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between equipment and the receiver.
Connect the equipment to an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
Covered by one or more claims of patents http://sipcollc.com/patent-list/ and
http://intusiq.com/patent-list/.
Correct disposal of batteries in this product
(Waste Electrical & Electronic Equipment)
(Applicable in countries with separate collection systems)				
This marking on the product, accessories or literature indicates that the product, its electronic
accessories (e.g. charger, headset, USB cable), and batteries should not be disposed of with other
household waste.
To prevent possible harm to the environment or human health from uncontrolled waste disposal,
please separate these items from other types of waste and recycle them responsibly to promote the
sustainable reuse of material resources. Where marked, the chemical symbols Hg, Cd or Pb indicate
that the battery contains mercury, cadmium or lead above the reference levels in EC Directive
2006/66. If batteries are not properly disposed of, these substances can cause harm to human
health or the environment.
Household users should contact either the retailer or installer from which they purchased this
product, or their local government office, for details of where and how they can take these items for
environmentally safe recycling. Business users should contact their supplier and check the terms
and conditions of the purchase contract. This product and its electronic accessories should not be
mixed with other commercial wastes for disposal.
WARNING: Failure to follow these warnings and instructions can lead to heat generation, rupture,
leakage, explosion, fire, or other injury, or damage. Do not insert the battery into the compartment
in the wrong direction. Always replace the battery with the same or equivalent type. Never recharge
or disassemble the battery. Never place the battery in fire or water. Always keep batteries away from
small children. If batteries are swallowed, promptly see a doctor.
Always dispose and/or recycle used batteries in accordance with the hazardous waste recovery and
recycling regulations for your location. Your city, state, or country may also require you to comply
with additional handling, recycling, and disposal requirements.
CONSTANT EXPOSURES TO HIGH OR LOW TEMPERATURES OR HIGH HUMIDITY MAY REDUCE
BATTERY LIFE.
One (1) Year Limited Warranty				
SmartThings, Inc. warrants this product (the “Product”) against defects in materials and/or
workmanship under normal use for a period of ONE (1) YEAR from the date of purchase by the
original purchaser (“Warranty Period”). If a defect arises and a valid claim is received within the
Warranty Period, then as your sole remedy (and SmartThings’ sole liability), SmartThings will at its
option either 1) repair the defect at no charge, using new or refurbished replacement parts, or 2)
replace the Product with a new product that is functionally equivalent to the original, in each case
within 30 days following receipt of the returned Product. A replacement product or part, assumes
the remaining warranty of the original Product. When a Product or part is exchanged, any
replacement item becomes your property and the replaced Product or part becomes SmartThings’
property.
Obtaining Service: To obtain warranty service, visit Support.SmartThings.com to speak with a service
agent or open a service request. Please be prepared to describe the Product that needs service
and the nature of the problem. A purchase receipt is required. The Product must be insured, and
shipped freight prepaid and securely packaged. You must contact support for a Return Material
Authorization Number (“RMA Number”) before shipping any Product, and include the RMA Number,
a copy of your purchase receipt and a description of the problem you are experiencing with the
Product. Any claim under this Limited Warranty must be submitted to SmartThings before the end
of the Warranty Period. Exclusions: This warranty does not apply to: a) damage caused by failure
to follow instructions relating to the Product’s use or the installation of components; b) damage
caused by accident, abuse, misuse, transport, neglect, fire, floods, earthquake or other external
causes; c) damage caused by service performed by anyone who is not an authorized representative
of SmartThings; d) accessories used in conjunction with a covered Product; e) a Product or part that
has been modified to alter functionality or capability; f) items intended to be periodically replaced
by the purchaser during the normal life of the Product, including, without limitation, batteries,
bulbs or cables; g) a Product that is used commercially or for a commercial purpose, in each case as
determined by SmartThings. EXCEPT FOR BODILY INJURY, SMARTTHINGS SHALL NOT BE LIABLE FOR
(I) ANY LOST PROFITS, COST OF PROCUREMENT OF SUBSTITUTE PRODUCTS, OR ANY INCIDENTAL
OR CONSEQUENTIAL DAMAGES, OR (II) ANY AMOUNTS IN EXCESS OF THE PURCHASE PRICE FOR
THE PRODUCT, IN EACH CASE WHETHER RESULTING FROM THE USE OF OR INABILITY TO USE THIS
PRODUCT, OR ARISING OUT OF ANY BREACH OF THIS WARRANTY, EVEN IF COMPANY HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION
OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION AND
EXCLUSIONS MAY NOT APPLY TO YOU. TO THE EXTENT PERMITTED BY APPLICABLE LAW,
SMARTTHINGS DISCLAIMS ANY AND ALL STATUTORY OR IMPLIED WARRANTIES, INCLUDING
WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE
AND WARRANTIES AGAINST HIDDEN OR LATENT DEFECTS. IF SMARTTHINGS CANNOT LAWFULLY
DISCLAIM STATUTORY OR IMPLIED WARRANTIES, THEN TO THE EXTENT PERMITTED BY LAW, ALL
SUCH WARRANTIES SHALL BE LIMITED IN DURATION TO THE WARRANTY PERIOD. SOME STATES DO
NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE
LIMITATIONS MAY NOT APPLY TO YOU.
This warranty gives you specific legal rights and you may also have other rights, which vary from
state to state. To exercise your rights under this warranty, please follow the instructions above
under the heading “Obtaining Service”, or contact SmartThings at SmartThings, Inc., 665 Clyde Ave,
Mountain View, CA 94043, USA. Samsung is a registered trademark of Samsung Electronics Co.,
Ltd. Android is a trademark of Google Inc. Other marks are the property of their respective owners.
Device purchase subject to additional SmartThings terms and conditions.
Samsung SmartThings Use of Free and Open-Source Software
This document contains licensing information relating to the use of free and open-source software
(FOSS) with or within the Samsung SmartThings software. Any terms, conditions, or restrictions on
FOSS included within the Samsung SmartThings software that are not included within the original
FOSS licenses are offered and imposed by Samsung SmartThings alone. The authors, licensors, and
distributors of the FOSS disclaim all express or implied conditions, representations, and warranties
relating to the FOSS and any liability arising from use and distribution of the FOSS. A document
containing the complete and current list of FOSS packages used in Samsung SmartThings software
and mobile applications can be found here: www.SmartThings.com/FOSS
The document at the URL above identifies the FOSS packages used in the Samsung SmartThings
Hub software, the FOSS licenses that Samsung SmartThings believes govern those FOSS packages,
and copyright and license notices associated with Samsung SmartThings’ use of the FOSS. While
Samsung SmartThings has sought to provide complete and accurate licensing information for each
FOSS package, Samsung SmartThings does not represent or warrant that the licensing information
provided herein is correct or error-free. Recipients of the product have the option to investigate
the identified FOSS packages to confirm the accuracy of the licensing information provided herein.
Recipients are also encouraged to notify Samsung SmartThings of any inaccurate information or
errors found in these notices. Certain FOSS licenses, such as the GNU General Public License, GNU
Lesser (or Library) General Public License, and Mozilla Public License, require Samsung SmartThings
to make available to recipients the source code corresponding to FOSS binaries distributed under
those licenses. Users who would like to download source code used by Samsung SmartThings under
those licenses can do so by logging in with their Samsung SmartThings account here:
https://graph.api.smartthings.com/foss_sources.
Users with questions or concerns regarding Samsung SmartThings use of Free or Open-Source
Software can contact us via email at: foss@smartthings.com
Deleting a Location (Home, Office, etc) in the SmartThings app will cause all Z-Wave devices to
be disconnected from the ADT Security Hub, requiring them to be excluded and re-included. Visit
Support.SmartThings.com for more information. P/N 10015713
SmartThings, Inc., 665 Clyde Ave, Mountain View, CA 94043, USA. Revised 05/17. Copyright 2017
SmartThings, Inc. All rights reserved. ADT and the ADT logo are marks and/or registered marks
of ADT. Unauthorized use is strictly prohibited. CA ACO7155, 974443, PPO17232; FL EF0001121;
LA F1639, F1640, F1643, F1654; MA 172C; NC Licensed by the Alarm Systems Licensing Board
of the State of North Carolina, 7535P2, 7561P2, 7562P10, 7563P7, 7565P1, 7566P9, 7564P4; NY
12000305615; PA 090797; MS 15019511.
P/N 10015713

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2017:06:05 11:58:20-07:00
Creator                         : Google
Modify Date                     : 2017:07:12 13:18:12-07:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.4-c006 80.159825, 2016/09/16-03:31:08
Metadata Date                   : 2017:07:12 13:18:12-07:00
Creator Tool                    : Google
Format                          : application/pdf
Document ID                     : uuid:d97fa00a-2eea-4e3d-8aa8-bf6878c8d5fe
Instance ID                     : uuid:69b58c5c-4d97-4300-a42f-831b688470f9
Producer                        : Mac OS X 10.12.5 Quartz PDFContext
Page Count                      : 21
EXIF Metadata provided by EXIF.tools
FCC ID Filing: EF400153

Navigation menu