Nortek Security and Control 00174 Water leak detector User Manual Users manual

Nortek Security & Control LLC Water leak detector Users manual

Users manual

Download: Nortek Security and Control 00174 Water leak detector User Manual Users manual
Mirror Download [FCC.gov]Nortek Security and Control 00174 Water leak detector User Manual Users manual
Document ID3852865
Application IDRdjpVfKtGHuZcTQ9utCVfg==
Document DescriptionUsers manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize26.7kB (333767 bits)
Date Submitted2018-05-16 00:00:00
Date Available2018-05-16 00:00:00
Creation Date2018-04-17 10:06:02
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2018-04-17 10:06:03
Document TitleUsers manual
Document CreatorAdobe InDesign CC 13.1 (Macintosh)

PRINTER’S INSTRUCTIONS:
INSTR,INSTL,2GIG-FT6 TEMP FLOOD SENSOR - P/N: 10021591 X4 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.5000” X 11.000” - TOL. +/- 0.125”- SCALE: 1-1 - PAGE 1 OF 2- FOLDING: FOLD 4X TO FINAL SIZE: 2.125" X 2.750"- FINISH WITH LOGO SHOWING
2GIG-FT6-345
FLOOD AND TEMPERATURE DETECTOR
INSTALLATION INSTRUCTIONS
Replacing Battery
The 2GIG-FT6-345 is a fully supervised, one-way 345 MHz sensor. It will monitor the
ambient temperature and/or will detect a wet/dry flood condition. The sensor reports
wet/dry conditions and temperature to the panel.
Figure 2. Opening the Sensor Case
Open Sensor Case as shown in Figures 2 and 3.
Flood Conditions
Once the sensor probe detects the presence of water, the integral transmitter will
immediately send a loop 3 wet alarm transmission to the panel. The probe will also
send a restore (dry) report when the presence of liquid is no longer detected. The
sensor is capable of detecting clean or dirty fresh water, salt water, or tap water.
The 2GIG-FT6-345 utilizes a unique design that can detect leaks dripping onto it’s
top or if there is water under the device. This dual sensing technology is perfect for
placement under P Traps or hoses that may leak, giving a warning just as the leak
starts. If a leak occurs at a different location as water is sensed under the device, it
will also send an alert.
ALIGN DOTS
Grip the base of the sensor case. Turn the top cover counter-clockwise to align the
dots, then separate the sensor case.
Figure 3. Installing New Battery
Temperature Conditions
Heat:
BATTERY TERMINAL
POSITIVE (+)
BATTERY TERMINAL
NEGATIVE (-)
BATTERY
PULL TAB
1. If the temperature is more than 95° F (35°C) for three (3) minutes, the sensor will
send a loop 2 transmission.
PULL O
NLY
WHEN
READY
TO PA
IR
2. If the temperature is less than 95°F (35°C) for three (3) minutes, the sensor will
send a loop 2 clear.
Cold:
1. If the temperature is less than 41°F (5°C) for three (3) minutes, the sensor will
send a loop 1 transmission.
2. In the temperature is more than 41°F (5°C) three (3) minutes, the sensor will
send a loop 1 clear.
Contents
Replacement Battery Installation:
NOTE: If battery has been previously installed:
Verify that the package includes the following:
• 1 — 2GIG Flood/Temperature Sensor
• 1 — 3V CR123A Lithium Battery
1.
2.
3.
4.
Figure 1. Temperature/Flood Sensor Contents
Remove battery, and dispose of properly (meeting state regulations).
Wait two (2) seconds.
Replace battery.
Close sensor.
Installing Temperature Sensor
SENSOR
The 2GIG-FT6-345 Flood and Temperature Sensor can be easily placed in any
location. If placed specifically under a potential leak source, use the included optional
double stick tape to secure it in the desired location (see Figure 6).
Figure 4. Suggested Installation Locations
Place the sensor in locations
that have the potential of
water leaks or flooding.
For example:
LITHIUM
•
•
•
•
LITHIUM BATTERY
Under the sink pipes
Adjacent to water heaters
Adjacent to toilets
Adjacent to bathtubs or
showers
• Under or near your
dishwasher
• Near washer and dryer
DETECTOR
WATER
1 Copyright © 2018 Nortek Security & Control
2GIG Flood & Temperature Control Instruction Manual
Flood Sensor Operation
Metal contacts on the top and bottom of the sensor detect water. Be certain to place
the sensor in a manner that does not impede the sensor’s ability to detect water.
Figure 5. Flood Sensor Contacts
METAL CONTACTS
(TOP)
METAL CONTACTS
(BOTTOM)
REGULATORY INFORMATION
This equipment has been tested and found to comply with the limits for Class B Digital Device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the
following measures.
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected
Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
Flood/Temperature Specifications
Operating Temperature:
32°to 104° F (0° to 40° C)
Operating Rel. Humidity:
5 to 95%, non-condensing
Operating Frequency:
345 MHz
Battery Type:
CR123A 3V lithium battery
Projected Battery Life:
5 Years
Supervisory Interval
70 Minutes
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio
exempts de licence. Ľexploitation est autorisée aux deux conditions suivantes: (1) ľappareil
ne doit pas produire de brouillage, et (2) ľutilisateur de ľappareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible ďen compromettre le fonctionnement.
FCC COMPLIANCE STATEMENT
This device complies with FCC Rules and Regulations as Part 15 devices as well as Industry
Canada license exempt RSS Rules and Regulations. Operation is subject to the following two
(2) conditions: This device may not cause harmful interference. This device must accept any
interference received, including interference that may cause undesired operation.
INDUSTRY CANADA (IC) COMPLIANCE
This device complies with Industry Canada license‐exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device
must accept any interference, including interference that may cause undesired operation of the
device. Repairs to certified equipment should be made by an authorized Canadian maintenance
facility designated by the supplier. Any repairs or alterations made by the user to this equipment,
or equipment malfunctions, may give the telecommunications company cause to request
the user to disconnect the equipment. Users should ensure for their own protection that the
electrical ground connections of the power utility, telephone lines and internal metallic water pipe
system, if present, are connected together. This precaution may be particularly important in rural
areas. Users should not attempt to make such connections themselves, but should contact the
appropriate electric inspection authority, or electrician, as appropriate.
LIMITED WARRANTY
This Nortek Security & Control LLC product is warranted against defects in material and
workmanship for two (2) years. This warranty extends only to wholesale customers who buy
direct from Nortek Security & Control LLC or through Nortek Security & Control normal distribution
channels. Nortek Security & Control does not warrant this product to consumers. Consumers
should inquire from their selling dealer as to the nature of the dealer’s warranty, if any.
There are no obligations or liabilities on the part of Nortek Security & Control for consequential
damages arising out of or in connection with use or performance of this product or other indirect
damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or
reinstallation. All implied warranties for functionality, are valid only until the warranty expires.
This Nortek Security & Control Warranty is in lieu of all other warranties expressed or implied.
For technical support in the USA and Canada:
855-2GIG-TECH (855-244-4832)
Email: 2gigtechsupport@nortek.com
Visit www.nortekcontrol.com for technical support hours of operation.
For technical support outside of the USA and Canada:
Visit dealer.2gig.com for a list of distributors in your region.
10021591 X4
2 Copyright © 2018 Nortek Security & Control

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Language                        : en-US
XMP Toolkit                     : Adobe XMP Core 5.6-c143 79.161424, 2017/09/22-11:52:47
Create Date                     : 2018:04:17 10:06:02-07:00
Metadata Date                   : 2018:04:17 10:06:03-07:00
Modify Date                     : 2018:04:17 10:06:03-07:00
Creator Tool                    : Adobe InDesign CC 13.1 (Macintosh)
Instance ID                     : uuid:51cb74ba-79c9-5042-8047-dea2b82c00db
Original Document ID            : xmp.did:066114573361E511A933A1F5E4D0E8CF
Document ID                     : xmp.id:324b07c1-80ab-4f03-8be4-d0329f38e289
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:68573f10-2c4a-4e1a-b0fe-8cbb4e946846
Derived From Document ID        : xmp.did:12B695E53063E611AA3FE2875FCD4EEF
Derived From Original Document ID: xmp.did:066114573361E511A933A1F5E4D0E8CF
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 13.1 (Macintosh)
History Changed                 : /
History When                    : 2018:04:17 10:06:02-07:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CC 13.1 (Macintosh)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: EF400174

Navigation menu