North Pole Engineering 414ANT ANT+ device. Battery powered or DC wall supply powered. User Manual

North Pole Engineering, Inc. ANT+ device. Battery powered or DC wall supply powered.

User Manual

Download: North Pole Engineering 414ANT ANT+ device. Battery powered or DC wall supply powered. User Manual
Mirror Download [FCC.gov]North Pole Engineering 414ANT ANT+ device. Battery powered or DC wall supply powered. User Manual
Document ID2273549
Application IDbJiW5LO6UXFpnouNfVp6IA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize24.43kB (305324 bits)
Date Submitted2014-05-21 00:00:00
Date Available2014-11-17 00:00:00
Creation Date2014-05-20 08:49:23
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2014-05-20 08:49:23
Document TitleUser Manual
Document CreatorMicrosoft® Office Word 2007
Document Author: Terry Flint

NPE BLAST User Guide
NPE 05-20-14
NPE’s BLAST sensor platform is intended for use with ANT connected networks and devices. These selfcontained BLAST based sensors are capable of measuring physical events via on-board sensors. The
sensor data can be logged in non-volatile memory and/or transmitted on ANT/ANT+ networks. The
device is powered by a single CR2032 coin cell battery and is intended to be replaced once depleted.
Required Equipment
BLAST sensor device
CR2032 coin cell
ANT network connectivity
In-situ sensory mounting apparatus
Typical installations based on application
Vibration Sensing
Bond sensor to object/surface of interest. Ensure no metallic objects impede RF transmission. This
application detects vibration to determine its state of operation and/or state of wear & tear.
Light Sensing
Bond sensor to surface whose light level is of interest. Ensure no metallic objects impede RF
transmission. The purpose is to quantify light levels incident on the board sensor. This determination
can be used to sense reflective objects or measure incident lux.
Magnetic Field sensing.
Bond sensor to object whose bearing is of interest. Ensure no metallic objects impede RF transmission.
The purpose is to determine the orientation/ bearing of an object.
Pairing Pod – RSSI measurement
Ensure minimal obstruction between BLAST and ANT transmitter. RSSI measurement is used to
determine proximity of ANT devices or to identify a specific ANT device by proximity.
Analog sensing
Place sensor near device of interest. Ensure no metallic objects impede RF transmission. One example
is measuring a Polar pulse signal and re-broadcasting in ANT format.
FCC Rules
Compliance Statement (Part 15.19)
The enclosed hardware device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2) This device must
accept any interference received including interference that may cause undesired operation.
Warning (Part 15.21)
Changes or modifications not expressly approved by North Pole Engineering could void the user’s
authority to operate the equipment. Manufacturer is not responsible for any radio or TV interference
caused by unauthorized modifications to this equipment.
Compliance Statement (Part 15.105(b))
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected
• Consult the dealer or an experienced radio/TV technician for help
Industry Canada (IC) regulatory information
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept
any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie
Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux
conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil
doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en
compromettre le fonctionnement.
Class B digital device notice
This Class B digital apparatus complies with Canadian
ICES-003, RSS-Gen and RSS-210.
Cet appareil numérique de la classe B est conforme à
la norme CAN ICES-3 (B)/NMB-3(B).


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 3
Language                        : en-US
Tagged PDF                      : Yes
Author                          : Terry Flint
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2014:05:20 08:49:23
Modify Date                     : 2014:05:20 08:49:23
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XRH-414ANT

Navigation menu