Novatel Wireless EDG0308 GSM/GPRS/EDGE Transmitter Module User Manual Enabler II G Assiste GPS Integration Guide
Novatel Wireless Inc. GSM/GPRS/EDGE Transmitter Module Enabler II G Assiste GPS Integration Guide
Integration Guide
Integration Guide: EDG0308IG001 Enfora Enabler IIIE Integration Guide Version: Draft Enfora Enabler IIIE Modem Integration Guide Document Title: Enfora Enabler IIIE Modem Integration Guide Version: Draft Date: 03/08/08 Status: DRAFT Document Control ID: EDG0308IG001 General All efforts have been made to ensure the accuracy of material provided in this document at the time of release. However, the items described in this document are subject to continuous development and improvement. All specifications are subject to change without notice and do not represent a commitment on the part of Enfora, Inc. Enfora, Inc. will not be responsible for any loss or damages incurred related to the use of information contained in this document. This product is not intended for use in life support appliances, devices or systems where a malfunction of the product can reasonably be expected to result in personal injury. Enfora, Inc. customers using, integrating, and/or selling this product for use in such applications do so at their own risk and agree to fully indemnify Enfora, Inc. for any damages resulting from illegal use or resale. Copyright Complying with all applicable copyright laws is the responsibility of the user. Without limiting the rights under copyright, no part of this document may be reproduced, stored in or introduced into a retrieval system, or transmitted in any form or by any means (electronic, mechanical, photocopying, recording or otherwise), or for any purpose, without the express written permission of Enfora, Inc. Enfora may have patents, patent applications, trademarks, copyrights or other intellectual property rights covering subject matter in this document. Except as expressly provided in any written license agreement from Enfora, the furnishing of this document does not give you any license to these patents, trademarks, copyrights or other intellectual property. ©2002, 2003, 2004, 2005, 2006, 2007, 2008 Enfora, Inc. All rights reserved. Enabler and Spider are either registered trademarks or trademarks of Enfora, Inc. in the United States. EDG0308IG001 Draft –03/07/2008 Enfora Enabler IIIE Modem Integration Guide Table of Contents 1. SAFETY PRECAUTIONS .................................................................................................................................1 1.1. 2. REGULATORY COMPLIANCE FCC.............................................................................................................1 2.1. 2.2. 3. IMPORTANT SAFETY INFORMATION ................................................................................................................1 INTEGRATION CONSIDERATIONS AND INSTALLATION REQUIREMENTS ...........................................................1 DISCLAIMER ...................................................................................................................................................3 MANUAL OVERVIEW......................................................................................................................................4 3.1. REVISION HISTORY.........................................................................................................................................4 3.2. REFERENCE DOCUMENTS ...............................................................................................................................5 3.2.1. Enfora Enabler IIIE Product Documentation........................................................................................5 3.2.2. GSM Device Specifications....................................................................................................................6 3.2.3. US Government......................................................................................................................................6 3.2.4. Federal Communications Commission (FCC).......................................................................................6 3.2.5. FCC Office of Engineering and Technology (OET) ..............................................................................6 3.2.6. Industry Canada ....................................................................................................................................6 3.2.7. Environmental Regulations....................................................................................................................6 3.2.8. Mechanical Specifications .....................................................................................................................7 3.2.9. RF and EMI Specifications ....................................................................................................................7 4. INTRODUCTION ...............................................................................................................................................8 4.1. PRODUCT OVERVIEW......................................................................................................................................8 4.2. KEY FEATURES OF THE ENABLER III MODULE ...............................................................................................8 4.3. WIRELESS DATA APPLICATION POSSIBILITIES ..............................................................................................10 4.4. SUMMARY OF FEATURES FOR THE ENABLER IIIE MODULE ..........................................................................11 4.5. GENERAL DESIGN GUIDELINES FOR UTILIZING ENFORA GSM MODULES ......................................................13 4.5.1. Advanced Tips for an RF Friendly Layout...........................................................................................14 4.5.1.1. 4.5.1.2. 4.5.1.3. 4.5.1.4. 4.5.2. 4.5.2.1. 4.5.2.2. 5. Ground Plane ................................................................................................................................................... 14 Thermal Relief ................................................................................................................................................. 14 Antenna and RF Signal Trace .......................................................................................................................... 16 Vbat Input ........................................................................................................................................................ 17 Audio Reference Design.......................................................................................................................19 Audio Schematics ............................................................................................................................................ 19 Audio Layout ................................................................................................................................................... 20 TECHNICAL SPECIFICATIONS ..................................................................................................................20 5.1. DETAILED PRODUCT SPECIFICATIONS ..........................................................................................................20 CLIMATIC: STORAGE AND TRANSPORTATION...........................................................................................................20 ELECTROMAGNETIC EMISSIONS ...............................................................................................................................20 Typical Operating Power ....................................................................................................................................21 5.1.1. Input Voltage Range ............................................................................................................................21 5.1.2. GSM Receiver Sensitivity.....................................................................................................................22 6. MECHANICAL .................................................................................................................................................23 6.1. MODULE MOUNTING TO HOST BOARD (REFERENCE)...................................................................................25 6.2. CONNECTORS ...............................................................................................................................................28 6.3. RF CONNECTION OPTIONS ...........................................................................................................................28 6.3.1. Coaxial Connector Option...................................................................................................................28 6.3.2. RF Board-to-Board Connector Option ................................................................................................28 6.3.3. I/O Connector Pin Assignments...........................................................................................................29 6.4. ...........................................................................................................................................................................30 6.5. CIRCUIT PROTECTION ...................................................................................................................................31 6.6. ANTENNA .....................................................................................................................................................32 EDG0308IG001 Draft –03/07/2008 Enfora Enabler IIIE Modem Integration Guide 6.7. CONTROL CONNECTOR SIGNAL DESCRIPTIONS AND FUNCTIONS .................................................................32 6.7.1. Module Power (Pins 85, 87, 89, 91, 93, 95, 97, 99) ............................................................................32 6.7.2. Reset Signal (Pin 37) ...........................................................................................................................33 6.7.3. Power Control (Pin 35) (PWR_CTL)..................................................................................................34 6.7.3.1. 6.7.3.2. 6.7.3.3. Turning ON the Enabler IIIE ........................................................................................................................... 34 Turning OFF the Enabler IIIE.......................................................................................................................... 34 Using the Power Control Signal....................................................................................................................... 35 6.7.4. Level Translation Reference Power (Pin 77).......................................................................................38 6.7.5. USB (Pins 1, 3, 5, 7, 9) ........................................................................................................................38 6.7.6. General Purpose Input/Output Interface .............................................................................................41 6.7.7. Serial Interfaces & Handshake (Pins 15, 21, 13, 11, 17, 25, 19, 23)...................................................41 6.7.8. Ring Indicate (Pin 23)..........................................................................................................................42 6.7.9. VBACKUP ...........................................................................................................................................44 6.7.10. 32 kHz output (Pin 56).........................................................................................................................45 6.7.11. Analog-To-Digital Input (Pin 74) ........................................................................................................45 6.7.12. Handset Microphone Input (Pins 65, 67).............................................................................................45 6.7.13. Handset Microphone Bias Output (Pin 63) .........................................................................................46 6.7.14. Handset Speaker Output (Pins 71, 73).................................................................................................46 6.7.15. Headset Microphone Input (Pin 55) ....................................................................................................47 6.7.16. Headset Microphone Bias Output (Pin 53)..........................................................................................47 6.7.17. Headset Speaker Output Left & Right (Pins 57, 59)............................................................................48 6.7.18. Headset Output Common Mode (Pin 61).............................................................................................48 6.7.19. Headset Detect (Pin 47).......................................................................................................................49 6.8. SUBSCRIBER IDENTITY MODULE (SIM) CARRIER (PINS 76, 78, 80, 82, 84) ................................................50 6.8.1. SIM Integration for the Enfora Enabler IIIE Module..........................................................................50 6.8.2. Using a Remote SIM with the Enfora Enabler IIIE Module (Pins 76, 78, 80, 82, 84).........................50 6.8.2.1. 7. Remote SIM Component Information.............................................................................................................. 52 GSM/GPRS MODES OF OPERATION .........................................................................................................53 7.1. 7.2. 7.3. 7.4. 8. ENABLING THE TRANSMISSION MODES FOR THE GSM/GPRS SERVICES .....................................................53 VOICE COMMUNICATION ..............................................................................................................................53 CIRCUIT-SWITCHED DATA ...........................................................................................................................53 SMS: SHORT MESSAGE SERVICES ................................................................................................................54 SIM OPERATION ............................................................................................................................................54 8.1. 8.2. 8.3. 8.4. 9. PROVISIONING THE SIM ...............................................................................................................................54 GSM SERVICES SUPPORTED BY THE ENFORA ENABLER IIIE MODULE ........................................................54 GPRS SERVICES SUPPORTED BY THE ENFORA ENABLER IIIE MODULE .......................................................55 SELECTING THE GSM MODES OF OPERATION ..............................................................................................55 SOFTWARE INTERFACE ..............................................................................................................................56 9.1. 9.2. 9.3. 10. SOFTWARE INTERFACE .................................................................................................................................56 FORMAT FOR THE AT COMMANDS ...............................................................................................................56 ENFORA AT COMMAND SET ........................................................................................................................56 SETUP AND INITIALIZATION.................................................................................................................57 10.1. GENERAL SETUP .......................................................................................................................................57 10.1.1. HyperTerminal Configuration for Enabler IIIE module......................................................................57 10.1.2. Initialization (AT Command Interface)................................................................................................58 10.1.3. Initial Response to the AT Command...................................................................................................59 10.1.4. Sending an Initialization String to the Enfora Enabler IIIE Module ...................................................59 10.1.5. Setting Up the Communication Mode for the Enfora Enabler IIIE Module ........................................60 10.1.6. Querying the Status of the Enfora Enabler III-G Module....................................................................60 10.1.7. Setting Module Reporting Parameters for GSM and GPRS ................................................................60 10.2. GSM/SMS EXAMPLES .............................................................................................................................61 10.2.1. Initialize the Enfora Enabler III-G Module to Send and Receive SMS Text Messages........................61 EDG0308IG001 Draft –03/07/2008 Enfora Enabler IIIE Modem Integration Guide 10.2.2. Managing SMS Messages ....................................................................................................................61 10.2.3. Data Call Configuration......................................................................................................................61 10.2.4. Voice Call Configuration.....................................................................................................................61 10.3. GPRS PACKET EXAMPLES .......................................................................................................................61 10.3.1. Windows PPP Setup.............................................................................................................................61 11. INTEGRATION AND TESTING ................................................................................................................62 11.1. 12. APPENDIX A - LIMITED WARRANTY ..................................................................................................64 12.1. 12.2. 12.3. 12.4. 13. INTEGRATING THE ENFORA ENABLER IIIE MODULE ................................................................................62 SCOPE .......................................................................................................................................................64 HARDWARE ..............................................................................................................................................64 SOFTWARE................................................................................................................................................64 OTHER CONSIDERATIONS .........................................................................................................................65 APPENDIX B - REGULATIONS AND COMPLIANCE ..........................................................................66 13.1. GCF/PTCRB APPROVAL (FORMERLY FTA) ............................................................................................66 13.2. ELECTROMAGNETIC COMPATIBILITY (EMC) AND SAFETY REQUIREMENTS.............................................66 13.3. EMC/SAFETY REQUIREMENTS FOR THE USA ..........................................................................................66 13.4. HUMAN EXPOSURE COMPLIANCE STATEMENT .........................................................................................67 13.5. COMPLIANCE WITH FCC REGULATIONS ...................................................................................................67 13.6. UNINTENTIONAL RADIATORS, PART 15....................................................................................................68 13.7. INTENTIONAL RADIATORS, PART 22 & 24................................................................................................68 13.8. INSTRUCTIONS TO THE ORIGINAL EQUIPMENT MANUFACTURER (OEM)..................................................69 13.8.1. OEM Responsibilities for All Products Containing the Enabler IIIE module .....................................71 13.8.2. Specific OEM Responsibilities for Portable Products and Applications .............................................72 13.8.3. Specific OEM Responsibilities for Mobile Products and Applications................................................72 13.8.4. Specific OEM Responsibilities for Fixed Products and Applications..................................................72 13.9. EMC/SAFETY REQUIREMENTS FOR THE COUNTRIES OF THE EUROPEAN UNION (EU)..............................73 13.10. EMC/SAFETY REQUIREMENTS FOR OTHER COUNTRIES ...........................................................................73 14. APPENDIX C - GLOSSARY AND ACRONYMS......................................................................................74 15. APPENDIX D – TABLES AND FIGURES.................................................................................................76 16. APPENDIX E - CONTACTING ENFORA.................................................................................................77 EDG0308IG001 Draft –03/07/2008 Enfora Enabler IIIE Modem Integration Guide 1. Safety Precautions 1.1. Important Safety Information The following information applies to the devices described in this manual. Always observe all standard and accepted safety precautions and guidelines when handling any electrical device. • Save this manual: it contains important safety information and operating instructions. • Do not expose the Enfora Enabler IIIE product to open flames. • Ensure that liquids do not spill onto the devices. • Do not attempt to disassemble the product: Doing so will void the warranty. With the exception of the Subscriber Identification Module (SIM), this product does not contain consumer-serviceable components. 2. Regulatory Compliance FCC 2.1. Integration Considerations and Installation Requirements The Enabler IIIE modem is designed for use in a variety of host units, "enabling" the host platform to perform wireless data communications. However, there are certain criteria relative to integrating the modem into a host platform such as a PC, laptop, handheld or PocketPC®, monitor and control unit, etc. that must be considered to ensure continued compliance with FCC compliance requirements. • Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. • In order to use the Enabler IIIE modem without additional FCC certification approvals, the installation must meet the following conditions: • Maximum RF output power and antenna gain to meet Maximum Permissible Exposure Requirements: GSM850 mode: Power at antenna port is +33 dBm, the maximum gain is 1.4 dBi. GSM1900 mode: Power at antenna port is 30 dBm, the maximum gain is 7.0 dBi. • If used in a "portable" application such as a handheld or body worn device with the antenna less than 20 cm (7.9 in.) from the human body when the device is operating, then the integrator is responsible for passing additional "as installed" testing and the device will require it’s own FCC ID: i. SAR (Specific Absorption Rate) testing, with results submitted to the FCC for approval prior to selling the integrated unit. If unable to meet SAR requirements, then the host unit must be restricted to "mobile" use (see below). ii. Unintentional emissions, FCC Part 15; results do not have to be submitted to the FCC unless requested, although the test provides substantiation for required labeling (see below). iii. ERP and EIRP measurements for FCC Parts 22 and 24, alternatively a full retest on FCC Parts 22 and 24 can be performed EDG0308IG001 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide • If used in a "mobile" application where the antenna is normally separated at least 20 cm (7.9 in) from the human body during device operation, then an appropriate warning label must be placed on the host unit adjacent to the antenna. The label should contain a statement such as the following: WARNING RF exposure. Keep at least 20 cm (7.9 in) separation distance from the antenna and the human body. • Host unit user manuals and other documentation must also include appropriate caution and warning statements and information. • If the FCCID for the modem is not visible when installed in the host platform, then a permanently attached or marked label must be displayed on the host unit referring to the enclosed modem. For example, the label should contain wording such as: Contains GSM/GPRS/EDGE modem transmitter module FCC ID: MIVEDG0308 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. OR Contains FCC ID: MIVEDG0308 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. • Any antenna used with the modem must be approved by the FCC or as a Class II Permissive Change (including MPEL or SAR data as applicable). The "professional installation" provision of FCC Part 15.203 does not apply. • The transmitter and antenna must not be co-located or operating in conjunction with any other antenna or transmitter. Violation of this would allow a user to plug another transmitter in to the product and potentially create an RF exposure condition. WARNING The transmitter and antenna must not be collocated or operating in conjunction with any other antenna or transmitter. Failure to observe this warning could produce an RF exposure condition. EDG0308IG001 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 2.2. Disclaimer The information and instructions contained within this publication comply with all FCC, GCF, PTCRB, R&TTE, IMEI and other applicable codes that are in effect at the time of publication. Enfora disclaims all responsibility for any act or omissions, or for breach of law, code or regulation, including local or state codes, performed by a third party. Enfora strongly recommends that all installations, hookups, transmissions, etc., be performed by persons who are experienced in the fields of radio frequency technologies. Enfora acknowledges that the installation, setup and transmission guidelines contained within this publication are guidelines, and that each installation may have variables outside of the guidelines contained herein. Said variables must be taken into consideration when installing or using the product, and Enfora shall not be responsible for installations or transmissions that fall outside of the parameters set forth in this publication. Enfora shall not be liable for consequential or incidental damages, injury to any person or property, anticipated or lost profits, loss of time, or other losses incurred by Customer or any third party in connection with the installation of the Products or Customer's failure to comply with the information and instructions contained herein. The Enabler IIIE platform is designed with features to support a robust connection. There are instances where the module performance is beyond the control of the intended design. Integrated designs that require 24 by 7 operation must implement power control via an external circuit or by implementing power management as specified within this design guide. EDG0308IG001 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 3. Manual Overview This document describes the hardware interface of the Enabler IIIE modem. The purpose of this document is to define the electrical, mechanical and software interfaces while providing detailed technical information in order to streamline the process of hardware and system integration. 3.1. Revision History Date 03/07/08 Rev Draft EDG0308IG001 Author Tom Cone Description Initial Release Draft Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 3.2. Reference Documents 3.2.1. Enfora Enabler IIIE Product Documentation Manuals • EDG0308AT001 - Enfora Enabler IIIE AT Command Set EDG0308IG001 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 3.2.2. GSM Device Specifications • 3GPP TS 51010-1 (850, 900,1800,1900 MHz devices) To view the latest release, go to: http://www.3gpp.org/ftp/Specs/html-info/51010-1.htm 3.2.3. US Government 3.2.4. Federal Communications Commission (FCC) Internet: http://www.fcc.gov/ • FCC Rules, Part 24 • • 47 CFR Subpart E--Broadband PCS 47 CFR § 24.52, sections 1.1307(b), 2.1091, and 2.1093 • FCC Rules, Part 22 for GSM 850 • FCC Rules, Part 15 • FCC Rules, Part 2 • • 3.2.5. Subpart J--Equipment Authorization Procedures Section 2.925 FCC Office of Engineering and Technology (OET) Internet: http://www.fcc.gov.oet/ 3.2.6. 3.2.7. • Bulletin Number 65 "Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields" • Supplement C "Additional Information for Evaluating Compliance of Mobile and Portable Devices with FCC Limits for Exposure to Radio Frequency Emissions" Industry Canada • RSS-132 • RSS-133 • ICES-003 Environmental Regulations • EDG0308IG001 National Environmental Policy Act (NEPA) of 1969 (Part 1, Subpart 1) Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 3.2.8. Mechanical Specifications • • • • • • • 3.2.9. ASTM D999 ASTM D775 IEC 68-2-27 Bellcore Gr-63-CORE ETS 300 019-1-1 Class 1.2 ETS 300 019-1-2 Class 2.1 ETS 300 019-1-3 Class 3.1 RF and EMI Specifications • • • • ETSI Standards EN 61000-4-6 EN 61000-4-3 3GPP TS 51.010-1, Section 12.2 EDG0308IG001 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 4. Introduction 4.1. Product Overview Enfora Enabler IIIE modem is a compact, wireless OEM module that utilizes the Global System for Mobile Communications (GSM), GPRS (General Packet Radio Services) and EDGE (Enhanced Data rates for GSM Evolution) international communications standards to provide twoway wireless capabilities via GSM services. The Enfora Enabler IIIE module is a fully Typeapproved GSM/GPRS/EDGE device, enabling application-specific, two-way communication and control. The small size of the Enfora Enabler IIIE module allows it to be integrated easily into the application and packaging. 4.2. Key Features of the Enabler III Module The following table summarizes the main features of the Enfora Enabler IIIE Radio Module. Interface Data input/output interface Primary serial port Secondary serial port GPIO USB Voice Antenna Interface Command protocol Subscriber Identification Module (SIM) Voltage backup Reference clock Power ADC Optional remote SIM Electrical power Peak currents and average power dissipation Radio Features Frequency bands GSM/GPRS/EDGE features supported EDG0308IG001 100 position 0.4mm pitch connector V.24 protocol, 1.8V levels, full 9-pin, UART implementation UART 1.8V Debug only (Enfora Use only) 8 GPIO. USB full-speed (FS) device compatible with the Universal Serial Bus Specification Revision 2.0 and the universal Serial Bus Specification Revision 1.1. (USB not available for customer use at this time) Supports four vocoder modes: full-rate (FR), enhanced full-rate (EFR), half-rate (HR), and adaptive multi-rate (AMR) Ultra-Miniature Coaxial Interconnect (MCD) or Board-to-Board Spring contact GSM AT command set Optional 1.8/3 V mini-SIM carrier and interface on board Voltage backup pin available to maintain RTC, battery capable 32kHz output reference clock (accessible via 100pin connector) 1 ADC port Accessible via the 100-pin connector 3.3 to 4.5 Vdc (vbat) Refer to the Operating Power table in the Technical Specifications for peak currents and average power dissipation for various modes of operation. EGSM 900, GSM1800, GSM 850 and GSM 1900 capability. Provides for all GSM/GPRS/EGPRS authentication, encryption, and frequency hopping algorithms. GPRS Coding Schemes CS1-CS4 supported. Multi-Slot Class 10 (4RX/2TX, Max 5 Slots). EGPRS Coding Schemes MCS1-MCS9 supported. Multi-Slot Class 10 (4RX/2TX, Max 5 Slots) Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide Regulatory GSM/GPRS Functionality Audio Features Outputs • • • • • • • • • • GCF Type Approval • PTCRB Type Approval • FCC Certification • RTTE • CE (European Community Certification) • IC (Industry Canada) Approval Mobile-originated and mobile-terminated SMS messages: up to 140 bytes or up to 160 GSM 7-bit ASCII characters. Reception of Cell Broadcast Message SMS Receipt acknowledgement Circuit Switched Data (Transparent & Non-transparent up to 9.6 Kbps) Voice (EFR, FR, HR) Supports Unstructured Supplementary Service Data (USSD) Multi-Slot Class 10 Supported (4Rx/2TX), (5 Slot Max) PBCCH/PCCCH Supported EGPRS Release 99 Handset Microphone biasing • Headset Microphone biasing • Headset Plug/Unplug detection • High output dynamic differential Earphone mode, using Headset outputs • Pop Noise attenuation circuitry implemented for all single-ended output stages • Mono Voice memo capability: Voice memo function is supported for both 8 kHz Narrowband and 16 kHz • Handset microphone input (MICIN, MICIP pins) • • Headset microphone input (HSMIC pin) Handset earphone outputs (EARP, EARN pins) • Headset 32 Ω stereo outputs (HSOL, HSOR pins) Agency approvals • Table 1 - Enabler IIIE Key Features EDG0308IG001 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 4.3. Wireless Data Application Possibilities A variety of applications can use the Enfora Enabler IIIE module for transmitting/receiving data/voice, such as: • Automated Meter Reading (AMR) • Point of Sale Applications • E-mail and Internet access • Automated Vehicle Location (AVL) • Machine to Machine communication (M2M) • Telematics • Telemetry • Wireless Security • Smart Phones • Telemedicine EDG0308IG001 10 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 4.4. Summary of Features for the Enabler IIIE Module The following summarizes the main features of the Enfora Enabler IIIE Module. Mechanical Dimensions................................... 34mm (L) x 28mm (W) x 2.5mm (H) Weight .......................................... 4.8 grams Packet Data Transfer: Protocol……………………………………………GPRS Release 99, EGPRS Release 4 Coding Schemes…………………………………CS1-CS4, MCS1-MCS9 Multi-Slot Class: (Demonstrated @MSC10)…….MSC10 (4RX/2TX) (Max 5 Slots) Packet Channel Support .............. ……………..PBCCH/PCCCH Circuit Switched Data Transfer: V110 ............................................. 300 bps/1200 bps/2400 bps/4800 bps/9600 bps/14,400 bps Non-Transparent .......................... 300 bps/1200 bps/2400 bps/4800 bps/9600 bps/14,400 bps Short Message Services: GSM SMS .................................... MO, MT, CB, Text and PDU Modes GPRS SMS .................................. MO, MT, CB, Text and PDU Modes Voice Capability: Speech Codec.............................. EFR, FR, HR, AMR GSM/GPRS/EGPRS Radio Performance Multi-Band: EDG0308 Radio Frequencies ...... 850 MHz, 900 MHz, 1800 MHz, and 1900 MHz Sensitivity ..................................... <-106 dBm 850 & 900 MHz Transmit Power .. Class 4 (2 W) 1800 & 1900 MHz Transmit Power Class 1 (1 W) System Requirements: Host Interface ............................... Serial Interface DC Voltage ................................... 3.3 to 4.5 Vdc EDG0308IG001 11 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide Application Interface: Host Protocol................................ AT Commands Internal Protocols ......................... PPP and CMUX Physical Interface......................... 1 serial UART primary (default baud rate 460800), 1 Serial Debug (RX and TX only) Audio Interface.............................. Handset microphone input (MICIN, MICIP pins), Headset microphone input (HSMIC pin), Handset earphone outputs (EARP, EARN pins), Headset 32 Ω stereo outputs (HSOL, HSOR pins) SIM Interface: Remote SIM Option 1.8/3-Volt SIM Capability Environmental: Compliant Operating Temp. ......... -20 °C to 60 °C (Fully GSM Spec Compliant) Operating Temperature ………….-30 °C to 70 °C Storage Temperature ................... -40 °C to 85 °C Humidity ....................................... 5 to 95% non-condensing EMC: Emissions ..................................... FCC Parts 15,22 & 24, Class B 3GPP TS 51010-1, Section 12.2 Operating Power (TYPICAL): GSM Operation GSM 850/900 (1 RX/1 TX, full power)………..275 mA average, 1.6 A peak GSM 1800 (1 RX/1 TX, full power)……………247 mA average, 1.3 A peak GSM 1900 (1 RX/1 TX, full power)……………230 mA average, 1.2 A peak Idle................................................ ………….. <2.2 mA Average in DRX 5 Shutdown ..................................... ……………≈ 45 uA GPRS Operation Power EGSM 850/900 (4 RX/1 TX, full power)…………… 275 mA average, 1.6 A peak EGSM 850/900 (2 RX/2 TX, full power)…………... 455 mA average, 1.6 A peak GSM 1800 (4 RX/1 TX, full power)………………… 250 mA average, 1.0 A peak GSM 1800 (2 RX/2 TX, full power) 408 mA average, 1.0 A peak GSM 1900 (4 RX/1 TX, full power)………………... 222 mA average, 1.0 A peak GSM 1900 (2 RX/2 TX, full power)………………… 375 mA average, 1.0 A peak Idle................................................ …………...…… <2.2 mA average in DRX 5 Shutdown ..................................... …………….….≈ 45 uA EDG0308IG001 12 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide EGPRS Operation Power EGSM 850/900 (3 RX/1 TX, full power)…………… 272 mA average, 1.6 A peak EGSM 850/900 (2 RX/2 TX, full power)…………... 280 mA average, 1.6 A peak GSM 1800 (3 RX/1 TX, full power)………………… 180 mA average, 1.0 A peak GSM 1800 (2 RX/2 TX, full power) 290 mA average, 1.0 A peak GSM 1900 (3 RX/1 TX, full power)………………... 175 mA average, 1.0 A peak GSM 1900 (2 RX/2 TX, full power)………………… 280 mA average, 1.0 A peak Idle................................................ …………...…… <2.2 mA average in DFX 5 Shutdown ..................................... …………….….≈ 45 uA GSM Transmit Power 1800/1900 MHz............................ GSM Power Class 1 (30 dBm ± 2 dB @ antenna connection) 850/900 MHz ................................ GSM Power Class 4 (33 dBm ± 2 dB @ antenna connection) GSM/GPRS/EDGE Receiver Sensitivity (Typical) 1800/1900 MHz............................ <-106 dBm, 850/900 MHz ................................ <-106 dBm, 4.5. General design guidelines for utilizing Enfora GSM modules The following guidelines are provided in an effort to allow Enabler IIIE module users to successfully implement their PCB layout to obtain the best performance. This includes the lowest possible EMI emissions, maximum thermal conduction, mechanical integrity, and voice quality. The Enabler IIIE module is a very compact, high performance design, yet it is easy to interface into the final product. In order to realize its full potential, designers should pay close attention to ground structures, the routing of RF and Digital traces, and the size of the power supply lines. These design tips are strictly guidelines and are not meant to be a complete list of items that guarantee actual performance. Each application is different and may require variation from these guidelines, however, care should be given to utilize these sound engineering principles whenever possible. EDG0308IG001 13 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 4.5.1. Advanced Tips for an RF Friendly Layout 4.5.1.1. Ground Plane To ensure the lowest possible EMI emissions and maximum thermal conductivity, it is recommended that all metal tabs on the GSM module shield must be soldered down onto a continuous ground plane that runs under the entire module. Ample ground vias should be provided around the metal tabs to create a low impedance ground. It is recommended to minimize the number of I/O and power traces and vias under the GSM module to allow for as much ground plane as possible. If the integrated unit includes more than one board, the design must guarantee a good RF ground connection between the boards in order to make sure the ground planes are at the same RF potential. An example of a good ground structure and pad layout is shown below in Figure 1. Figure 1 - Example of good ground plane for GSM modules 4.5.1.2. Thermal Relief Because the ground plane acts as a large heat sink, it can affect the solderability of components. A common method to reduce this effect is to use thermal relief around the pad in question. However, great care must be taken when using thermal relief for high current or high frequency applications EDG0308IG001 14 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide For example, a large thermal relief like the one shown in Figure 2 can serve the purpose for general applications such as low current, low speed data lines, DC connections and audio frequency applications. Such thermal relief structures should be avoided for applications where high current and/or high frequency is involved, such as those using the Enabler Module. Depending on the frequency of operation, the long narrow thermal relief traces between the pad and the ground plane act like an RF choke. These RF chokes become higher impedance at harmonics of the fundamental frequency making it problematic for high frequency suppression. This can make it difficult to pass type approval testing. POOR RF thermal relief Figure 2 - Example of a POOR RF Thermal Relief If thermal relief is necessary, it is recommended that you use short, fat traces similar to those shown in Figure 3. This will still provide a solderable connection, while providing a better RF connection. Making them shorter also allows for a more continuous ground plane due to less copper being removed from the area. It is also recommended to have ground vias around all thermal relief of critical ground pins such as the five Enabler shield tabs. EDG0308IG001 15 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide GOOD RF thermal relief Figure 3 - Example of a GOOD RF Thermal Relief 4.5.1.3. Antenna and RF Signal Trace The PCB trace that feeds the RF output port must be designed for a 50 ohm characteristic impedance, coplanar, or routed into internal layers to keep the top layer continuous around and underneath the Enabler module. Ample ground vias should be provided around the RF contacts, the RF trace and launch pad. If possible, keep I/O and power traces away from the RF port. This includes traces running parallel or orthogonal to it. Thermal relief should not be used on the antenna output port ground pads. The designer must pay close attention to the size of the pad and thickness of the dielectric beneath the signal pad and trace. Most PCB manufacturers can adjust the trace width to maintain 50 ohms impedance if the traces are identified and instructions are included on the FAB drawing. This service is typically provided at no or minimal additional cost. For minimum RF emissions due to the fundamental frequency of operation, the Enabler module works best with an antenna load that has a VSWR of 1.5:1 or better. The antenna should not have gain at the harmonic frequencies, otherwise, the conducted harmonics could get amplified to a point where the product no longer passes type approval. However, for applications where antenna quality is less than ideal, it is recommended to have a low pass filter (Pi structure with N=3) in the RF path to the antenna. This is a secondary plan should there be a need to lower harmonic levels at frequencies above the PCS band. The pad structure may also be used to match the antenna load impedance, if required. If it is not needed, a capacitor of low reactance may be used to bridge the Pi structure. The RF cable going between the Enable module and the antenna is very lossy, therefore, the length of this cable should be kept as short a possible. EDG0308IG001 16 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide If multiple antennas are used in their design, care should be taken during placement selection to minimize the coupling between the GSM antenna and the other antennas. 4.5.1.4. Vbat Input The Enabler Vbat input can have a relative high current draw that can fluctuate rapidly, especially when transmitting at max power and burst mode. The Vbat interface must be designed to provide the required instantaneous voltage and current with minimal voltage droop. This includes both sufficient bulk decoupling capacitance as well as adequate layout provisions. When laying out the connections to the Enabler interface connector, it is tempting to use traces of the same width as the connector pins. However, this is a very compact connector and traces of that width will not have sufficient copper. Similar to the discussion on thermal relief, the use of narrow traces to connect the Vbat pins to the source voltage can act like a high impedance and cause a significant voltage droop when higher currents are required as shown in Figure 4. Figure 4 - Example of Vbat Voltage Droop If the Vbat drops too low, the Enabler modules will reset. To minimize the trace loss, it is suggested to use a larger trace that spans several pins as shown in Figure 5. Any concern about solderability can be mitigated by using solder mask with cutouts for the individual pins as shown by the blue lines in the figure. The layout should provide sufficient trace width over the entire trace from the Enable modules all the way to the source of the Vbat voltage. Any transitions between layers for this trace should utilize multiple vias. EDG0308IG001 17 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide Since even the best layout will have some impedance from the source to the Enabler module, sufficient bulk decoupling capacitance is required at the Vbat input to the Enabler module. It is suggested to use at least two 1000 uF, low ESR, tantalum capacitors located very close to the Enabler interface connector Vbat pins. Any thermal relief used on these capacitors should comply with the information given above in order to provide the lowest impedance possible. The grounding of these capacitors is critical. Therefore, it should be a low impedance and should utilize multiple vias to the internal ground plane close to the capacitor as well. Vbat trace Figure 5 - Example of GOOD Vbat layout EDG0308IG001 18 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 4.5.2. Audio Reference Design The audio quality is very dependent on the circuit design and layout. As an aid to obtaining good audio quality, a reference design has been included below. It has been proven to provide good performance on the SDK module. 4.5.2.1. Audio Schematics Figure 6 - Audio Reference Design Schematic EDG0308IG001 19 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 4.5.2.2. Audio Layout Layout plots for the audio section of the SDK are available upon request. 5. Technical Specifications 5.1. Detailed Product Specifications Physical Dimensions and Weight Size (L x W x H) 34mm x 28mm x 2.5mm Weight Without SIM Connector – < 4.8 grams With SIM Connector (no SIM inserted) – < 5.2 grams Climatic: Operational GSM Compliant temperature Operating temperature -20°C to +60°C -30°C to +70°C Relative humidity 5 - 95% Air pressure (altitude) 70 kPa to 106 kPa (-400 m to 3000 m) Climatic: Storage and Transportation Ambient temperature Relative humidity -40°C to +85°C 5% to 95%, non condensing (at 40C) Electromagnetic Emissions Radiated spurious FCC Part 22 & 24 / Part 15 Class \ B 3GPP TS 51.010-1 Section 12.2 EDG0308IG001 20 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide Typical Operating Power 5.1.1. Input Voltage Range The modem operates within performance specifications over the input voltage range of: Input Voltage Range 3.3 to 4.5 Vdc CAUTION: Any excursions above or below this range may cause the module to deviate from RF performance specifications and/or cause damage to the module. Test Conditions: Typical Results @ 3.7 V with 2000 μF at connector input on VBAT with RF antenna terminated into a 50 Ω resistive load. GSM Operation Band Mode 1900 1800 1 RX/1 TX, Full Power 900 850 ALL DRX2 Idle DRX5 Idle DRX9 Idle N/A Shutdown Low 28 29 27 29 Input Current Nom/Avg 230 247 275 275 3.55 2.15 1.78 45 High/Peak 808 885 1000 1000 110 110 110 1420 Units mA mA mA mA mA mA GPRS Operation Band Mode 4 RX/1TX, Full Power 1900 2 RX/2TX, Full Power 1 RX/1TX, Full Power 4 RX/1TX, Full Power 1800 2 RX/2TX, Full Power 1 RX/1TX, Full Power 4 RX/1TX, Full Power 900 2 RX/2TX, Full Power 1 RX/1TX, Full Power 4 RX/1TX, Full Power 850 2 RX/2TX, Full Power 1 RX/1TX, Full Power ALL DRX2 Idle DRX5 Idle DRX9 Idle N/A Shutdown Low 22 22 24 23 24 24 25 23 22 24 24 23 Input Current Nom/Avg 222 375 220 250 408 235 285 455 265 275 455 260 3.55 2.15 1.78 45 High/Peak 815 1105 805 885 1180 875 1015 1350 1010 1005 1350 1000 110 110 110 1420 Units mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA uA EDG0308IG001 21 uA Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide EGPRS Operation Power EGPRS Operation Band Mode 3 RX/1TX, Full Power 1900 2 RX/2TX, Full Power 1 RX/1TX, Full Power 3 RX/1TX, Full Power 1800 2 RX/2TX, Full Power 1 RX/1TX, Full Power 3 RX/1TX, Full Power 900 2 RX/2TX, Full Power 1 RX/1TX, Full Power 3 RX/1TX, Full Power 850 2 RX/2TX, Full Power 1 RX/1TX, Full Power ALL DRX2 Idle DRX5 Idle DRX9 Idle N/A Shutdown 5.1.2. Low 29 32 27 28 28 28 27 28 27 27 28 28 Input Current Nom/Avg 175 280 175 180 290 177 180 265 180 185 280 185 3.55 2.15 1.78 45 High/Peak 720 800 715 680 850 740 875 865 760 875 900 865 110 110 110 1420 Units mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA uA GSM Receiver Sensitivity Enfora Enabler IIIE module Sensitivity -106 dBm (typical) 1900 MHz 1800 MHz 900 MHz 850 MHz EDG0308IG001 -106 dBm (typical) 22 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 6. Mechanical Figure 7 shows the mechanical footprint for the module. The outline dimensions are applicable to the module with and without the onboard SIM holder. Figure 7 – Side View and Top View EDG0308IG001 23 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide Figure 8 – Side View and Top View EDG0308IG001 24 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 6.1. Module Mounting to Host Board (Reference) The module provides mounting tabs that must be soldered to a PCB. These tabs provide circuit grounding for the module. Figure 9 – Module Mounting EDG0308IG001 25 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide Figure 10 - Shield Mounting Pads EDG0308IG001 26 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide Figure 11 - Host Pads for Board-To-Board RF Connector EDG0308IG001 27 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 6.2. Connectors On The Modem: 100-Pin I/O Connector, Plug, SMT, Dual Row, 0.4 mm Pitch Enfora PN = CON-1040-0100 Molex PN = 55909-1074 On The Host: 100-Pin I/O Connector, Socket, SMT, Dual Row, 0.4 mm Pitch (Mate to module) Enfora PN = CON-1040-0101 Molex PN = 51338-1074 The mated height of the two connectors is 1.50 mm. Full details of the mechanical requirements for these can be found from the Molex website 6.3. RF Connection Options 6.3.1. Coaxial Connector Option On The Modem: Sunridge MCD Series – Ultimate Miniature Coaxial Interconnect, 1.55mm Mated Height Contact Sunridge for mating cable options: Enfora PN = CON-0009-0005 Sunridge PN = MCD-ST-00T http://sunridgecorp.com/ Sunridge Corporation 2500 E. Foothill Blvd. Suite 107 Pasadena, CA 91107 U. S. A. Tel: (626) 535-1780 Fax: (626) 535-1788 6.3.2. RF Board-to-Board Connector Option On The Modem: Enfora PN = CON-0009-0006 Sunridge PN = MCE-15A-G01 On The Host PCB: No connector required. See Figure 11 for layout details. EDG0308IG001 28 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 6.3.3. I/O Connector Pin Assignments The following table shows the pin assignments for the input/output connector. Table 2 - Enabler IIIE Pin Assignments Pin # 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 Serial Pin I/O Enabler IIIE Description/Comments (Default Function / Secondary Function I/O VBUS GND VBUS GND USB_DP RESERVED USB_DM RESERVED ID_USB RESERVED UART_RTS RESERVED UART_CTS RESERVED UART_RX RESERVED UART_DTR RESERVED UART_DCD RESERVED UART_TX RESERVED UART_RING RESERVED UART_DSR RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED PWR_CTL RESERVED RESET RESERVED UART_TX_DBG RESERVED UART_RX_DBG RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED USB power – Tie to ground if USB not used System Ground USB power – Tie to ground if USB not used System Ground 5 V tolerant data plus pin in USB modes RESERVED 5 V tolerant data minus pin in USB modes RESERVED USB connector identification RESERVED UART Request to send RESERVED UART Clear to send RESERVED UART Serial data output RESERVED UART Data Terminal Ready RESERVED UART Data carrier detect RESERVED UART Serial data input RESERVED UART / Modem ring indicated RESERVED UART Data Set Ready RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED External switch-on event (ON Button) with 32-kHz de-bouncing RESERVED External RESET input RESERVED Debug UART Serial data input RESERVED Debug UART Serial data output RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED I/O EDG0308IG001 29 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide Pin # Serial Pin I/O Enabler IIIE 53 54 55 56 57 58 59 60 61 62 I/O I/O I/O 63 64 65 66 67 68 69 70 71 72 73 74 75 76 I/O I/O I/O I/O I/O PWR HSMICBIAS GND HSMIC CLK32K_BUF HSOL GPIO_4 HSOR GPIO_3 HSOVMID USB_BOOT/ GPIO_2 MICBIAS GPIO_1 MICIP GPIO_7 MICIN GPIO_5 GND GPIO_6 EARP GPIO_8 EARN ADCIN4 GND VRSIM 77 78 PWR VRIO SIM_CLK 79 80 RESERVED SIM_RST 81 82 I/O RESERVED SIM_IO 83 84 VBACKUP SIMDTC 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 VBAT GND VBAT GND VBAT GND VBAT GND VBAT GND VBAT GND VBAT GND VBAT GND Description/Comments (Default Function / Secondary Function Headset microphone bias System ground Microphone input (Headset) 32.768 kHz out, only buffered by 10 kΩ resistor 32 kΩ headset amplifier Left GPIO 4 32 kΩ headset amplifier Right GPIO 3 Headset output common mode GPIO 2 Microphone bias GPIO 1 Microphone amplifier positive input (Handset) GPIO 7 Microphone amplifier negative input (Handset GPIO 5 System Ground GPIO 6 33 Ω or 120 Ω speaker amplifier (+) (Analog) GPIO 8 33 Ω or 120 Ω speaker amplifier (-) (Analog) 10-bit A-to-D System Ground Output voltage for SIM 1.8 V / 2.85 V (No Connect if onboard SIM holder is used) 1.8 V out – Reference for external level translation SIM Card Reference clock (No Connect if onboard SIM holder is used) RESERVED SIM Card Reset (No Connect if onboard SIM holder is used) RESERVED SIM Card I/O Data (No Connect if onboard SIM holder is used) Backup Battery Voltage SIM card insertion/extraction detect with 32-kHz debouncing. (No Connect if onboard SIM holder is used) Power from Host System Ground Power from Host System Ground Power from Host System Ground Power from Host System Ground Power from Host System Ground Power from Host System Ground Power from Host System Ground Power from Host System Ground 6.4. EDG0308IG001 30 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 6.5. Circuit Protection Other than very low level ESD protection within the module’s integrated circuits, the module does not have any protection against ESD events or other excursions that exceed the specified operating parameters. Generally, ESD protection (typically TVS/Transzorb devices) should be added to all signals that leave the host board. This includes VBAT/VCC. Series resistors (typically 47 Ω) can also be added in series with data lines to limit the peak current during a voltage excursion. Minimum ESD Protection Levels Pin #’s ESD Test Method Pins 11 – 24, 26-34, 36, 38, 40, 42, 48, 50, 52, 58, 60, 62, 64, 66,68, 70, 72, 78, 80, 82 Pins (all VBUS/PWR), 5 – 10, 35, 37, 47, 49, 51, 52, 53, 55 – 57, 59, 61, 63, 65, 67 Min ESD/Input Voltage Nom/ High/ Avg Peak Units Human Body Model EIA/JEDEC22-A114-A Charge Device Model EIA/JEDEC22-C101-A 500 200 Human Body Model EIA/JEDEC22A114-A Charge Device Model EIA/JEDEC22C101-A 2000 500 Caution – It is the Integrator’s responsibility to protect the Enabler IIIE module from electrical disturbances and excursions, which exceed the specified operating parameters. EDG0308IG001 31 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 6.6. Antenna The EDG0308-xx module has one RF antenna connection on the module. 6.7. Control Connector Signal Descriptions and Functions Please note that the following descriptions are intended to provide hardware-level definitions. In some cases, specific lines will have no firmware functionality implemented. Information for each hardware-specific feature will be noted in the appropriate section. 6.7.1. Module Power (Pins 85, 87, 89, 91, 93, 95, 97, 99) The Enfora Enabler IIIE module uses a single voltage source of VCC=+3.3V to 4.5V. (The exact values of the uplink currents are shown in the tables in section 5.3.1.) VBAT Main Battery Supply Parameter/Conditions Voltage In Regulation Peak Current 1000 μF on Host at Module Connector Min 3.3 Typ Max 4.5 Units Vdc mA The uplink burst will cause strong ripple on the voltage lines and should be effectively filtered. It is recommended that 1000 to 2000 μF of capacitance be placed as close to the modem I/O connector as possible. It should be noted that the input voltage level should not drop below the minimum voltage rating under any circumstances, especially during the uplink burst period. The Board to Board Connector is very delicate. When handling the module, do NOT handle by the Board to Board Connector. EDG0308IG001 32 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 6.7.2. Reset Signal (Pin 37) The Reset signal is used to force the modem to start at a known state. When the Reset is pulled low the modem will immediately suspend any function and will not exit the reset state until the Reset signal is released to be pulled high. Once the transition from low to high is complete, the modem will boot. The Reset signal is falling edge triggered, so the reset function is set immediately when the signal is pulled low. When using Reset, it will immediately detach the connection from the GSM network, this is not considered ideal. Typically during a normal shutdown, the modem will issue a detach request to the network to indicate that it is being removed. Reset must not be used to ‘power off’ the device, but only as a last resort when there is no response from the module. Controlling the Reset signal must only be preformed by an open collector/open drain device. Driving the Reset signal high will interfere with the normal operation of the modem power on/off sequences. Power sequencing cannot be guaranteed if Reset is being driven high by an external device. If driving from an external microprocessor, the reset can be controlled by driving the control pin low as an output, then change the pin control to be an input, this will satisfy the high impedance requirement. The Reset pin can also be monitored as a system on/off indication. When the modem is powered on and in a normal operating state, this pin will be set high. When the modem is powered down or in the ‘off’ state, this pin will be low. Any monitoring circuit MUST be high impedance, such as a logic gate or microprocessor input. Parameter VIL VIH IPU IIL Reset Pulse Duration EDG0308IG001 Parameter/Conditions Input Voltage – Low or float Input Voltage – High Internal Pull-Up Resistor Current sink MIN TYP 1.36 -40 -31 MAX 0.58 1.95 -15 -2.0 50 33 Draft – 03/07/2008 UNIT Vdc Vdc μA mA mS Enfora Enabler IIIE Modem Integration Guide 6.7.3. Power Control (Pin 35) (PWR_CTL) The input is equivalent to a “phone ON-button”. A falling-edge on this Active-Low input will switch-ON the module or switch-OFF the module after a delay*. This input has a “weak pull-up” resistor internal to the module. This input can be left grounded if the “RTC Sleep Function” is not required. If RTC Sleep is required, then the PWR_CTL line must be floated to allow the internal resistor to pull the line high. See section 6.6.9 for more info on the RTC. Controlling the Power Control signal must only be performed by an open collector/open drain device. Driving the Power Control signal high may interfere with the normal operation of the modem. If driving from an external microprocessor, the Power Control can be controlled by driving the control pin low as an output, then change the microprocessor’s pin control to be an input (this will satisfy the high impedance requirement). *The OFF Delay is controlled by the AT$OFFDLY command. A value of 0 disables the PWR_CTL line from turning the module off. 800 milliseconds is the default value. To enable the module to switch-OFF via PWR_CTL you must set AT$OFFDLY to a value other than 0. The valid range is 100 to 10000 milliseconds. 6.7.3.1. Turning ON the Enabler IIIE Pulling the PWR_CTL line on the Enabler IIIE LOW for at least 50mS (after Vbat is applied and stabilized) is required to turn it ON. Section 6.7.3.3 describes various ways to provide the signal. Do not use a pull-up resistor on the PWR_CTL line since the line is pulled up internal to the modem. 6.7.3.2. Turning OFF the Enabler IIIE The Enabler IIIE can be turned off by either a low pulse on the PWR_CTL line, or by a software command (AT$OFF, see AT guide for further details). Section 6.7.3.3 describes various ways to provide the signal. EDG0308IG001 34 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 6.7.3.3. Using the Power Control Signal Typical use powering module on/off with a switch: Figure 12 – Power Control Switch EDG0308IG001 35 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide Typical use controlling PWR_CTL from microcontroller: Typical connection of PWR_CTL to modem: Modem VBAT PWR_CTL RESET Float Figure 13 - External Power Control Signal (no external processor) shows a typical connection to the Enfora Enabler IIIE module in a machine-to-machine application using the external PWR_CTL signal, when there is not an external processor controlling the power on/off states. The RTC deep sleep functions will NOT function since the PWR_CTL pin is tied low, the processor will never stay in a “RTC Sleep” mode. To reset the module, either the RESET pin is toggled as described in the ‘Reset Signal’ section, or power (VBAT) must be cycled. Modem VBAT PWR_CTL Float RESET Figure 13 - External Power Control Signal (no external processor) EDG0308IG001 36 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide Figure 14 - Power Control Signal (using external processor) shows a typical connection from an external processor to the Enfora Enabler IIIE module, using the external PWR_CTL signal. The Enfora Enabler IIIE can be powered on by using the PWR_CTL signal, and reset with the RESET signal. When using PWR_CTL, the I/O or serial lines can be at any voltage state desired. It is recommended that the I/O and serial lines be tristated or set low when the GSM0308 is shutdown for an extended period of time to prevent any leakage current from the processor to the modem. CPU Modem VBAT GPIO SERIAL Open drain, or Tri-State I/O PWR_CTL Open drain, or Tri-State I/O RESET Figure 14 - Power Control Signal (using external processor) Parameter VIL VIH IPU IIL ON Pulse Duration OFF Pulse Duration Boot time EDG0308IG001 Parameter/Conditions Input Voltage – Low or float Input Voltage – High Internal Pull-Up Resistor Current sink Minimum is programmable (AT$OFFDLY) Time to boot from power on to command prompt 37 MIN TYP 2.1 -40 -31 50 100 1000 MAX 0.9 1.95 -15 -2.0 10000 Draft – 03/07/2008 UNIT Vdc Vdc μA mA mS mS Sec Enfora Enabler IIIE Modem Integration Guide 6.7.4. Level Translation Reference Power (Pin 77) To be used as a voltage reference source ONLY. Do not connect current loads to this pin. This pin must be decoupled to ground with at least a 0.1 μF capacitor at the output. Noise induced on this pin will affect the performance of the baseband. VR I/O Output voltage VOUT Rated output current IOUT 6.7.5. Parameter/Conditions ON mode LOW POWER mode ON mode LOW POWER mode Min 1.65 1.65 Typ 1.8 1.8 Max 1.95 1.95 20 0.5 Units Vdc mA USB (Pins 1, 3, 5, 7, 9) Pin Name Pin Number 1, 3 Signal Direction In USB_DP/RXD/MIC_R USB_DM/TXD/SPKR_L ID_USB Analog I/O Analog I/O Analog I/O USB_VBUS Description 5 V tolerant power Supply VBUS line; Used only as a USB sense, not for powering the module. (optional connection) 5 V tolerant data plus pin in USB modes / Receive function in UART mode / 5 V tolerant data minus pin in USB modes / Transmit function in UART mode / 5 V tolerant ID line, it defines the type of device connected to the phone’s USB port; And also the default state (host / device) at the cable connection; The transceiver senses the voltage of this pin to determine if the pin is either floating (typical),grounded or resistively connected to ground (102 kΩ, 200 kΩ, 440 kΩ); The universal serial bus (USB) device controller supports the implementation of a full-speed (FS) device compatible with the Universal Serial Bus Specification Revision 2.0 and the Universal Serial Bus Specification Revision 1.1. The module includes a Universal Serial Bus (USB) transceiver which is able to support USB 12 Mb/s FullSpeed (FS) and USB 1.5 Mb/s Low-Speed (LS). When a USB cable is plugged into the USB receptacle, the transceiver detects the cable’s presence on VBUS (> 1.8 V) and ID (≠ float) pins, even if the module is switched off. The transceiver is fully operational only in phone’s Active mode. EDG0308IG001 38 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide USB Power (pins 1,3) Filtering Capacitor Filtering Capacitor ESR Input Voltage VIN B-Device (SRP Capable, Peripheral-Only) Average Current VBUS Wake-Up Threshold Parameter/Conditions Connected from VRUSB to GNDD ON mode, in regulation 0 V ≤ VBUS ≤ 5.25 V Min Typ 1.0 4.7 2.7 5.0 Max Units µF 300 5.25 mΩ Vdc mA 1.6 1.8 2.0 Min 4.4 2.8 0.0 -2 Typ 4.65 3.3 0.1 Max 5.25 3.6 0.3 Units Vdc Vdc μA 5V Tolerant Transceiver USB Input Voltage Output voltage Parameter/Conditions High (Driven) Low Transceiver D+/Leakage Current EDG0308IG001 39 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide USB Port In Input Levels Serial Interface Input High RXD Input High On D+ Serial Interface Input Low RXD Input Low On D+ Parameter/Conditions Output Levels Serial Interface Input High RXD Input High On DSerial Interface Input Low RXD Input Low On D- Parameter/Conditions ISOURCE = 4 mA Min 2.4 ISOURCE = -4 mA 0.0 EDG0308IG001 40 Min 2.0 Typ Max Units Vdc 0.8 Vdc Typ 3.3 Max 3.6 Units Vdc 0.1 0.4 Vdc Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 6.7.6. General Purpose Input/Output Interface GPIO number GPIO 1 GPIO 2 GPIO 3 GPIO 4 GPIO 5 GPIO 6 GPIO 7 GPIO 8 Pin number 64 62 60 58 68 70 66 72 Each general-purpose signal may be selected as inputs or outputs. GPIO1-GPIO8 may be controlled independently as a single group. See EDG0308AT001 for AT Command control. I/O Lines VIL VIH VOL VOH IOL / IOH 6.7.7. Parameter/Conditions Input Voltage – Low Input Voltage – High Output Voltage – Low Output Voltage – High Rated Output Current Min 1.17 Typ Max 0.60 1.8 0.45 1.26 Units Vdc Vdc Vdc Vdc mA Serial Interfaces & Handshake (Pins 15, 21, 13, 11, 17, 25, 19, 23) In an effort to make the naming convention less confusing for integrators, the Enabler IIIE is referenced as the DTE (similar to Enabler II products) as opposed to the enabler IIIG that was originally referenced as a DCE. Please note that neither the pin assignments nor the direction of the pins have changed, only the naming conventions. Pin Name UART_RX UART_TX UART_CTS UART_RTS UART_DTR UART_DSR UART_DCD UART_RING EDG0308IG001 Pin Number 15 21 13 11 17 25 19 23 Signal Direction 41 Description Serial data output Serial data input Clear to send Request to Send Data Terminal ready Data Set ready Data carrier detect Ring detect output Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide The key features of the UART in the modem mode are as follows: •16C750 compatibility • Baud rate from 75 bits/s up to 460800 Kbits/s, (460800 default) •Configurable data format: Data bit: 5, 6, 7, or 8 bits Parity bit: even, odd, none Stop bit: 1, 1.5, 2 bit(s) •Hardware flow control RTS/CTS Default settings are 8 data, 1 stop, no parity. DTR may be used to force the modem into AT command mode from online data mode (See AT Command Document, command AT&D). RTS and CTS may be used for hardware handshaking. DSR is always active (connected to ground) while the modem is on. RING may be used to alert the host to a variety of incoming calls. For a minimal implementation, connect RxData, TxData and ground to the corresponding COM port serial data lines. Verify the applicable functions are disabled in the modem (AT+IFC, AT&D, AT&C). UART Lines VIL VIH VOL VOH IOL / IOH Parameter/Conditions Input Voltage – Low Input Voltage – High Output Voltage – Low Output Voltage – High Rated Output Current 6.7.8. Min 1.17 Typ Max 0.60 1.8 0.45 1.26 Units Vdc Vdc Vdc Vdc mA Ring Indicate (Pin 23) The Enabler IIIE module is capable of using the Ring line to discern the type of incoming call. The indicator can be monitored via a hardware line available on the 100-pin I/O signal connector. The function of the Ring line depends on the type of the call received. EDG0308IG001 42 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide When the module is receiving a voice call, the Ring line goes low for 1 second and high for another 2 seconds. Every 3 seconds the ring string is generated and sent over the Receive (Data Out) (Rx) line. If there is a call in progress and call waiting is activated for a connected handset or hands free device, the Ring pin switches to ground in order to generate acoustic signals that indicate the waiting call. Ring 2 seconds 1 second 2 seconds 1 second RING String RING String When a Fax or data call is received, Ring goes low and will remain low. Every 3 seconds a ring string is generated and sent over the Receive (Data Out) (Rx) line. Ring 3 seconds 3 seconds RING String RING String RING String When an incoming SMS is received , Ring indicate goes low for 1 second, then returns to a high state. See below logic diagram. Ring 1 second URC Figure 15 - Ring Indicate Timing Serial I/O & Control VIL VIH VOL VOH IOL / IOH EDG0308IG001 Parameter/Conditions Input Voltage – Low Input Voltage – High Output Voltage – Low Output Voltage – High Rated Output Current 43 Min 1.26 1.26 Typ Max 0.54 1.95 0.54 1.95 2.0 Draft – 03/07/2008 Units Vdc Vdc Vdc Vdc mA Enfora Enabler IIIE Modem Integration Guide 6.7.9. VBACKUP VBACKUP is a backup voltage input that can maintain the RTC clock and alarm functions. If VBACKUP is not present in the system (intentionally or not) the RTC clock may still be powered if leakage voltage exists on VCC. Otherwise, the RTC clock will lose power and be reset when VCC is restored. PARAMETER Parameter/Conditions Backup Voltage (Real-Time-Clock) Backup Voltage for Real-Time-Clock VBACKUP Input Current (VBACKUP = 3.2 V, VBAT = 0 IBACKUP V, No Load on GPIO or Serial Port) Min Typ Max 2.7 3.0 3.0 4.5 6.0 Units Vdc μAdc VBACKUP had been tested in the above scenarios and does not contribute to leakage. It will properly provide backup power to the RTC clock. EDG0308IG001 44 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 6.7.10. 32 kHz output (Pin 56) A 32.768 kHz signal is available as an output from the module. This signal should only be used as an input to a high impedance device. Additional loads or capacitance on the line may cause performance issues with the module. If the line is not used, leave floating. 32kHz Clock-Out VIH VIL Maximum capacitor load Maximum resistive load Frequency Parameter/Conditions Min Typ Max tbd ± 30 ppm 32.768 Units Vdc Vdc pF Ω kHz 6.7.11. Analog-To-Digital Input (Pin 74) The monitoring ADC (MADC) consists of a successive approximation 10–bit analog–to–digital converter (ADC). Analog-To-Digital Input ADCBRES ADCREF VADC Integral/Differential NonLinearity Input Leakage Retuning Frequency Parameter/Conditions ADC Binary Resolution ADC Reference Voltage ADC Range Min Typ Max 10 Units Bits Vdc Vdc LSB 1.75 -2 1.75 μA MHz tbd 6.7.12. Handset Microphone Input (Pins 65, 67) The handset differential inputs MICIP and MICIN can be amplified by the differential handset microphone amplifier. This amplifier has a gain of 25.6 dB and a bias generator MICBIAS provides an external voltage of 2 V or 2.5 V to bias the microphone. Handset Mic Input Maximum Input Range – Mic(+) to Mic(-) Nominal Ref. Level – Mic(+) to Mic(-) Differential Input Resistance – Mic(+) to Mic(-) Microphone PreAmplifier Gain EDG0308IG001 Parameter/Conditions Inputs 3 dBm0 (Max. digital sample amplitude when PGA gain set to 0 dB) Differential MIC Differential MIC, MICAMP gain = 25.6 dB (INMODE = 0001) Differential MIC 45 Min Typ Max 32.5 Units mVRMS -10 dBm0 36 kΩ 25.6 dB Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 6.7.13. Handset Microphone Bias Output (Pin 63) Mic Bias Output Bias Voltage on Mic(+) Parameter/Conditions Set to 2.0 V Set to 2.5 V Min 1.9 2.4 Typ Max 2.1 2.6 2.0 Mic Bias Current Capability Units Vdc Vdc mA 6.7.14. Handset Speaker Output (Pins 71, 73) Pin Name EARP EARN Pin Number 71 73 Signal Direction Description Earphone positive output Earphone negative output The earphone amplifier provides a full differential signal on the terminals EARP and EARN (Earphone). Handset Spkr Output Maximum Differential Resistive Load Maximum Differential Capacitive Load Common Mode Minimum Resistive Load Common Mode Maximum Capacitive Load Amplifier Gain Parameter Earphone output swing at EARP-EARN Earphone amplifier gain Earphone amplifier state in power down Earphone amplifier power supply rejection Parameter/Conditions Output Swing 3.9 VPP Output Swing 1.5 VPP Min Typ 120 33 Max 100 At Internal Speaker (+) or (-) 200 kΩ At Internal Speaker (+) or (-) EARG = 1 EARG = 0 50 -11 Test Conditions Distortion ≤ 2% and 120 Ω, VSP input level = +3 dBm0, amp gain = -11 dB Distortion ≤ 2% and 33 Ω, VSP input level = -5.34 dBm0, amp gain = -11 dB Distortion ≤ 2% and 120 Ω, I2S input level = +3 dBm0, amp gain = -11 dB Distortion ≤ 2% and 120 Ω, VSP input level = +3 dBm0, amp gain = 1 dB Distortion ≤ 2% and 33 Ω, VSP input level = -5.34 dBm0, amp gain = 1 dB Distortion ≤ 2% and 120 Ω, I2S input level = +3 dBm0, amp gain = 1 dB EARG = 1 EARG = 0 Min pF DB dB Typ 0.98 Max Units VP-P 0.38 0.93 3.1 3.92 1.2 1.5 2.96 3.7 -11 High dB dB 50 dB 1 kHz, 100 mVp-p An external audio amplifier should be used for loads of less than 16 Ω or if volume is inadequate. EDG0308IG001 Units Ω Ω pF 46 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 6.7.15. Headset Microphone Input (Pin 55) The headset differential inputs HSMIC and AUXI can be amplified by the differential handset microphone amplifier. This amplifier has two different gains 4.9 dB or 25.6 dB and a bias generator HSMICBIAS provides an external voltage of 2 V or 2.5 V to bias the microphone. Mic Input Maximum Input Range Nominal Ref. Level Microphone PreAmplifier Gain Input resistance at HSMIC Parameter/Conditions Inputs 3 dBm0 (Maximum digital sample amplitude with PGA gain set to 0 dB), AUXAMP gain = 18 dB, Single HSMIC Min Typ Max 78 Units mVRMS 18 dBm0 dB -10 HSMIC single input, AUXAMP gain = 18 dB 40.5 kΩ 6.7.16. Headset Microphone Bias Output (Pin 53) Mic Bias Output Bias Voltage on Mic(+) Parameter/Conditions Set to 2.0 V Set to 2.5 V Mic Bias Current Capability EDG0308IG001 47 Min 1.9 2.4 Typ Max 2.1 2.6 2.0 Draft – 03/07/2008 Units Vdc Vdc mA Enfora Enabler IIIE Modem Integration Guide 6.7.17. Headset Speaker Output Left & Right (Pins 57, 59) Pin Name HSOL HSOR HSOVMID Pin Number 57 59 61 Signal Direction Description Headset Out 32Ω Speaker Left Headset Out 32Ω Speaker Right Headset Out pseudo ground return The left and right headset amplifiers provide the stereo signal on terminals HSOL and HSOR. A pseudo ground is provided on terminal HSOVMID to eliminate external capacitors. The mono audio signal can be provided on the Right or the Right and Left headset outputs. HSOVMID is available to allow integrators to supply a bias or DC offset to increase the dynamic range of the Headset. Headset Spkr Output Maximum Swing Parameter/Conditions Distortion ≤ 2% and 32 Ω, VSP input level = +3 dBm0 Distortion ≤ 2% and 32 Ω, I2S input level = +3 dBm0 Min 1.6 Typ 1.96 1.48 1.85 Maximum Capacitive Load Minimum resistive load at HSOL and HSOR: Zload Amplifier Gain HSOL/R amplifier Power supply rejection 1 kHz, 100 mVpp Amplifier State in Power Down Max Units VP-P 100 pF 32 Ω -5 50 dB dB High Z The left and right channels of the headset speaker output are a single ended output. An external audio amplifier should be used for loads of less than 32 Ω or if volume is inadequate. 6.7.18. Headset Output Common Mode (Pin 61) The left and right headset amplifiers provide the stereo signal on terminals HSOL and HSOR. A pseudo ground is provided on terminal HSOVMID to eliminate external capacitors. HSOVMID Maximum Capacitor Load DC Level EDG0308IG001 Parameter/Conditions 48 Min Typ Max 200 Units pF 1.2 1.35 1.5 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 6.7.19. Headset Detect (Pin 47) Headset Plug/Unplug detection. This pin is used to automatically switch to the headset audio path when enabled with AT$VSELECT=4. The device will default to handset when no Headset is detected. • 2 modes: Module already ON (Battery connected, VRIO ON) and plug event; Module OFF and plug event: the plug detection will be effective once VRIO is set ON • Plug and unplug detections are digitally debounced (debouncing time = 8 ms). • The jack plug detection feature is addressed through the HSDET pin. The integrated pull up, connected to the pin, forces a high level (VBAT) when the headset load is not connected. At jack insertion headset load connection (32 Ω) imposes a low level on that node (Headset left channel): as an example HSDET = 1 mV after jack plug for VBAT = 4 V. • Input comparator threshold voltages are defined as VTlow = VBAT/2 – 100 mV and VThigh = VBAT/2 + 100 mV, VBATmin = 3.2 V. The plug and unplug detection remains functional if there is no signal from HSOL amplifier output (stereo path is OFF) or if there is a signal from HSOL (stereo path is ON): maximum level on HSOL when the stereo path is ON is 1 Vp-p which stays far enough from the comparator threshold levels VBATmin/2 – 100 mV and VBATmin/2 + 100 mV. • Jack plug detection is functional if a plug event occurs before the power up of the module or if the plug event occurs after the power up of the module: analog detection part is always active if the battery is connected. Detection interrupts will be generated once the VRIO regulator is power up during the module power up sequence. • A level change on HSDET pin is sensed by a Schmitt trigger to provide a jack detection signal to the audio digital control. The audio digital control receives the detection signal and proceeds to a digital debouncing (time: 8 ms = 256 * 32 kHz clock periods) before sensing that a plug event happened on the jack connector. Headset Detect Low level input voltage VIL related to VBAT Parameter/Conditions High level input voltage VIH related to VBAT TYP MAX 0.3 * VBAT 0.7 * VBAT Current with pull-up EDG0308IG001 MIN -40 49 UNIT -31 -15 Draft – 03/07/2008 μA Enfora Enabler IIIE Modem Integration Guide 6.8. Subscriber Identity Module (SIM) Carrier (Pins 76, 78, 80, 82, 84) The SIM, an integral part of any GSM terminal device, is a “smart card” that is programmed with subscriber information: • The user information consists of an International Mobile Subscriber Identity (IMSI) number, which is registered with the GSM provider, and an encryption Ki (pronounced "key"). This information consists of a microprocessor and memory installed on a plastic card. Note: The SIM is not provided with the Enfora Enabler IIIE module. The SIM must be obtained from the GSM service provider and must be provisioned by the operator for data and/or voice. Always take care to protect the SIM: the GSM terminal will not operate without the SIM installed. The SIM provides the IMSI for authentication. To gain access to the GSM network, the network must recognize the IMSI number, and the terminal must be able to properly decrypt the data sent by the network. The SIM also serves as a buffer for SMS messages, storing the message for transmission until a radio link is available and buffering received messages until retrieved. 6.8.1. SIM Integration for the Enfora Enabler IIIE Module The Enabler IIIE module default configuration does not include an on-board SIM carrier. Enfora provides a separate product SKU for the Enabler IIIE module with the integrated SIM carrier. 6.8.2. Using a Remote SIM with the Enfora Enabler IIIE Module (Pins 76, 78, 80, 82, 84) The Enabler IIIE module default configuration does not include an on-board SIM carrier. The module supports the use of 1.8 V and 3 V SIM cards. The module includes a hardware interface module dedicated to Universal Subscriber Identity Module (USIM). All baud-rates defined in ISO 7816-3 standard are supported for high-speed transmission. The module optionally includes an on-board SIM carrier. All other modules require a remote SIM carrier/connector. If the module is going to be integrated using a remote SIM, the following guidelines are provided: • To utilize a remote SIM, the integrator must provide a suitable SIM connector. • The maximum distance from the module to the remote SIM connector must not exceed 25.4 cm (10 inches). • External ESD Protection is Required; 15 kV Air Discharge; 8 kV Contact Discharge; The transorb must have a low junction capacitance (typically < 10 pf) such as the following part: Enfora PN: TRS-0000-5009 Manufacturer: On Semi Manufacturer PN: NSQA6V8AW5T2G EDG0308IG001 50 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide <25.4 cm (10 in) Enabler IIIE module Remote SIM SIM Interface SIM_VDD SIM_RST SIM_CLK SIM_DTC SIM_I/O Figure 16 - Remote SIM Interface Pin Name SIM_VDD SIM_CLK SIM_RST SIM_I/O SIMDTC Pin Number 76 78 80 82 84 Signal Direction I/O Description SIM VDD Card Reference Clock Card Reset Card I/O Data Card detect The module provides the regulated supply voltage for the SIM-card and the circuitry to detect the insertion or extraction of the SIM-Card in or from the mobile. The SIMDTC is disabled by default (see AT$SIMDTC in the EIII AT Command Manual for settings). When enabled, the SIMDTC pin has an internal pull up to Vcc and can be configured to detect a SIM insertion when the SIMDTC is either pulled to ground or left floating. It can configured to detect either just a SIM removal or both removal and insertion. When the module detects a SIM removal, it will de-register from the network. When the module is configured to and detects a SIM insertion, it will reset the module and re-register on the network. The SIM-card presence detection logic is active even when the system is in idle mode. EDG0308IG001 51 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide USIM VDD Parameter/Conditions SIM VDD voltage VIH VIL VOH VOL II Iout PU PD Iz High level input voltage Low level input voltage High level output voltage, IO = 4 mA Low level output voltage, IO = 1 mA Input leakage current Output current PU resistance PD resistance Leakage current Debouncing time (SIM-card insertion) Debouncing time (SIM-card extraction) Pull-up resistor (resistor + resistive switch) Card Detect Min 1.65 2.7 1.15 Typ 1.8 2.85 Max 1.95 2.95 0.61 Vdd-0.45 0.4 ±1 32 30 ± 30 0.5 15 475 6.8.2.1. Remote SIM Component Information Any compatible SIM carrier can be used in conjunction with the Enabler IIIE module. For example: Lumberg P/N 8840_A_21. or Suyin P/N: 254016MA006G103ZL EDG0308IG001 52 Draft – 03/07/2008 Units μA mA kΩ kΩ μA mS mS kΩ Enfora Enabler IIIE Modem Integration Guide 7. GSM/GPRS Modes of Operation GSM/GPRS supports many optional services and modes. The Enfora Enabler IIIE module supports the following GSM/GPRS services: • Circuit-switched data • Short-Message Services (SMS) • Class B GPRS Functionality • Voice communication 7.1. Enabling the Transmission Modes for the GSM/GPRS Services Each of the GSM/GPRS services has two modes that can be enabled separately: • Mobile-originated (MO): allows the making of a service request (such as, making a telephone call or sending an SMS) • Mobile-terminated (MT): allows receiving a service request (such as receiving a telephone call or an SMS) Note: Contact your local GSM operator to ensure that the services and modes have been provisioned for the SIM. 7.2. Voice Communication The Enfora Enabler IIIE module has full voice capabilities, provided the necessary connections have been made for the speaker and microphone pins on the 100-pin I/O connector. The Enfora Enabler IIIE AT Command Set Reference- EDG0308AT001MAN has the entire list of commands that can be used to control the voice functionality. The quick start guide in this manual provides a basic command set that can be used to initialize and test the voice functionality. The Enfora Enabler IIIE module supports four vocoder compression algorithms for voice communication: Full-Rate (FR), Enhanced Full-Rate (EFR), Half-rate (HR) and Adaptive Multi-rate (AMR). 7.3. Circuit-Switched Data In this mode, the Enfora Enabler IIIE module supports both of the connection modes of transmission that are provided by GSM: • Non-Transparent mode delivers a constantly low error rate but with a non-guaranteed throughput or delay. The Non-Transparent service provides a performance that is closest to using a modem over a fixed Public Switched Telephone Network (PSTN) line. Note: All GSM service providers may not support transparent mode. In those cases, the Enfora Enabler IIIE module can be configured to switch automatically to Non-Transparent mode. This capability depends on the settings in the AT+CBST command. EDG0308IG001 53 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 7.4. SMS: Short Message Services • Short Message Services (SMS) is a feature-rich GSM service. The Enfora Enabler IIIE module can perform the following tasks: • Sending and receiving binary messages of up to 160 characters (7-bit characters) • Sending and receiving text messages of up to 140 bytes (8-bit data) • Submitting a SMS Protocol Data Unit (PDU) to a SMSC (Short Message Service Center) and storing a copy of the PDU until either a report arrives from the network or a timer expires • Receiving a SMS PDU from a SMSC • Returning a delivery report to the network for a previously received message • Receiving a report from the network • Notifying the network when the module has sufficient memory capacity available to receive one or more SMS messages (after the module had previously rejected a message because its memory capacity was exceeded) 8. SIM Operation 8.1. Provisioning the SIM The SIM can support optional features or services. Most operators typically configure the SIM to send/receive voice calls and to receive SMS; however, some may require an additional tariff to enable the SIM to send SMS. The transmission of circuit switched and GPRS data are also additional services that may be required to allow the service: • Mobile-originated (MO): allows making a service request (such as, making a call or sending an SMS) • Mobile-terminated (MT): allows receiving a service request (such as, receiving a phone call or an SMS) It is imperative for the Enfora Enabler IIIE module that the SIM be configured for the optional services that are required for the application. 8.2. GSM Services Supported by the Enfora Enabler IIIE Module The Enfora Enabler IIIE module supports four GSM services (modes of operation) that must be enabled by the operator: • Voice calls (MO and MT): requires a telephone number • SMS (MO and MT): uses the telephone number for Voice • Circuit-switched data calls (MO and MT): requires a telephone number • The GSM SIM can have multiple telephone numbers. EDG0308IG001 54 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 8.3. GPRS Services Supported by the Enfora Enabler IIIE Module The Enfora Enabler IIIE module supports the following GPRS (modes of operation) that must be enabled by the operator: • GPRS Packet Connectivity (MO and MT) with Both Dynamic and Static IP option • GPRS SMS (MO and MT): uses the IP (Dynamic or Static) set by the operator • Multiple APN Setting • Quality of Service Options • Multi-slot 10 Class of Service EGPRS Services Supported by the Enfora Enabler IIIE Module • Multiple APN Setting • Quality of Service Options Multi-slot 10 Class of Service MCS5- MCS9 8.4. Selecting the GSM Modes of Operation When provisioning the SIM for the Enfora Enabler IIIE module, enable the following modes of operation: • Voice calls: configure the SIM for both MO and MT service (to send and receive) • SMS: configure the SIM either for MT alone (to receive) or for both MO and MT (to send and receive) • Circuit Switched Data: configure the SIM either for MO alone (to send) or for both MO and MT (to send and receive) Voice MO/MT MO/MT MO/MT SMS MT MO/MT MO/MT EDG0308IG001 CS Data MO MO MO/MT GPRS Function Voice calls, receive SMS, make data calls Voice calls, receive / send SMS, make data calls Voice calls, receive / send SMS, make / receive data calls (requires an additional data telephone number) 55 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 9. Software Interface 9.1. Software Interface The application sends commands to the Enfora Enabler IIIE module via the 100-pin I/O signal connector. These commands use the Enfora AT Command Set The Enfora Enabler IIIE module operates in one of the following modes: • Command mode: Used for configuring the Enfora Enabler IIIE module, for interrogating the GSM network, and for placing and receiving calls. It uses the AT command set via the serial port for communication. • On-line mode: Used after a circuit-switched data call has been established. Data is passed between the Enfora Enabler IIIE module and the controlling application without command interpretation. The only AT command that is interpreted in On-line mode is the +++ command. (This command places the Enfora Enabler IIIE module in Command mode but does not terminate the circuit-switched data call.) 9.2. Format for the AT Commands The general format of the command line is:AT See AT Command Manual 0X0D The prefix AT obtains synchronization, identifies the character parameters, and indicates that a command may be in the following characters. Most AT commands are not case sensitive: use either capital letters or lower-case letters for the AT command. Note: Some AT Command parameter values ARE case sensitive and are documented in the Enfora EDG0308AT001 - Enfora Enabler IIIE AT Commands. 9.3. Enfora AT Command Set For a full description of the AT commands, refer to the Enfora EDG0308AT001 - Enfora Enabler IIIE AT Commands. Note: A command description that includes an *asterisk denotes that the GSM service provider must enable supplementary services functionality before the command is available. EDG0308IG001 56 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 10. Setup and Initialization 10.1. General Setup The EDG0308 modem is controlled through the Modem RS232 port on the development board. Connect a nine pin straight through serial cable from the Modem RS232 connector to the serial port on the controlling computer. Hook up power supply, connect antenna, and install SIM into modem. 10.1.1. HyperTerminal Configuration for Enabler IIIE module The following provides an example for setting up a Windows HyperTerminal session that can be used to experiment with various configurations on the Enabler IIIE module for controlling computer: 1. Select the connection interface, Direct to Com 1 (or whatever port is the serial port). Figure 17 – Hyper Terminal Definition EDG0308IG001 57 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 2. Configure the COM port as displayed below. Figure 18 - COM Port Settings 10.1.2. Initialization (AT Command Interface) In the GSM vocabulary, a call from GSM mobile to the PSTN is called a "mobile-originated call" or "outgoing call". A call from the fixed network to a GSM mobile is called a "mobile-terminated call" or "incoming call." In the following examples, “Entry” refers to the application. The following convention describes the direction of the data exchange: • The data exchange from the customer application to the Enfora Enabler IIIE module is designated as: Entry The data exchange from the Enfora Enabler IIIE module to the customer application is designated as: Response Note: With the exception of the +++ command (Online Escape Sequence), all commands must be preceded by the AT attention code (or command prefix) and terminated by pressing the character. EDG0308IG001 58 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide In the following examples, the and are intentionally omitted for clarity and space. 10.1.3. Initial Response to the AT Command After power is applied to the Enfora Enabler IIIE module, the module performs a power-up selftest. The self-test completes within one (1) second. When queried with the AT command, the Enfora Enabler IIIE module responds with one of the following result codes: • OK signifies that the Enfora Enabler IIIE module is ready, that it correctly interprets the AT command, and that it has executed the command. • ERROR signifies that the Enfora Enabler IIIE module does not understand the command or that the command is invalid. Entry Response AT OK Command valid: module is ready The Enfora Enabler IIIE module must be in AT Command mode (please refer to section 10.3 GPRS Packet Examples for packet mode initialization and setup) when any command is entered (with the exception of the online escape sequence). Commands entered when the module is in On-line mode are treated as data, and are transmitted as such to the receiving module. i.e. If the module is in PPP, AT commands cannot be entered. 10.1.4. Sending an Initialization String to the Enfora Enabler IIIE Module The following example provides the sample AT commands and responses for the following initialization tasks: • Reset the module to the factory defaults • Disable character echo • Transmit Result Codes • Set the module to Verbose mode (to display result codes as words) • Set the DCD to match the state of remote modem • Ignore the DTR Entry Response Entry Response EDG0308IG001 AT&FE0Q0V1&C1&d0 OK ATSO=1 OK Initialization string Command is valid Auto answer on 1st ring Command is valid 59 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 10.1.5. Setting Up the Communication Mode for the Enfora Enabler IIIE Module The following example sequence provides the AT command and response for setting the Enfora Enabler IIIE module for full phone functionality, automated operator selection, 9600 baud, nontransparent mode. Entry Response Entry Response Entry Response AT+CFUN=1 OK AT+COPS=0 OK AT+CBST=7,0,1 OK FULL phone functionality Command is valid Automatic operator selection Command is valid 9600 baud, non-transparent mode Command is valid 10.1.6. Querying the Status of the Enfora Enabler III-G Module This topic is addressed in the Enfora Application Note GSM0000AN006 – Enabler-G Module Status Query. 10.1.7. Setting Module Reporting Parameters for GSM and GPRS This topic is addressed in the Enfora Application Note GSM0000AN007 - Enabler-G Status Reporting. EDG0308IG001 60 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 10.2. GSM/SMS Examples 10.2.1. Initialize the Enfora Enabler III-G Module to Send and Receive SMS Text Messages This topic is addressed in the Enfora Application Note GSM0000AN004 SMS Configuration and Use. 10.2.2. Managing SMS Messages This topic is addressed in the Enfora Application Note GSM0000AN004 SMS Configuration and Use. 10.2.3. Data Call Configuration This topic is addressed in the Enfora Application Note GSM0000AN003 Data Circuit Switched Call. 10.2.4. Voice Call Configuration This topic is addressed in the Enfora Application Note GSM0000AN003 Data Circuit Switched Call. 10.3. GPRS Packet Examples 10.3.1. Windows PPP Setup The Enabler III-G module can be used in a Windows operating system environment as a standard serial modem device. The required setup and configuration process is contained in Enfora Application Notes GSM0000AN008 - PPP Configuration for Windows XP EDG0308IG001 61 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 11. Integration and Testing The Enfora Enabler IIIE module has been designed to minimize the amount of time required for integration and testing the application. By being fully certified by the appropriate bodies, the Enfora Enabler IIIE module provides seamless integration into the GSM network. The integration issues for the application can be narrowed to the utilization of the AT commands and the use of the GSM functionality. Coverage and signal quality may be evaluated by using the RSSI commands. Additional network information can be determined by using AT commands. Integration of the GPRS Packet capabilities is more complicated than using AT command sequences to initiate the connection and begin transferring data. The following Application Notes should be used to integrate the GPRS packet capabilities: GSM0000AN001 - Enabler-G PPP Configuration for Windows 98 GSM0000AN002 - Enabler-G PPP Configuration for Windows 2000 GSM0000AN008 - Enabler-G PPP Configuration for Windows XP GSM0000AN010 - Enabler-G PPP Configuration for PocketPC 2002 GSM0000AN005 - Enabler-G Automated Network Connection Configuration and Use 11.1. Integrating the Enfora Enabler IIIE Module Note: Generally, all interfaces that are externally available to the end user need to be ESDconditioned and terminated in some way. Many of these interfaces should not be connected with power applied. At the highest level, this is done using some type of GSM test equipment (such as, Racal 6103E), a computer, and a serial interface tester. The GSM test equipment must be able to simulate a GSM call and measure the key parameters related to the module. Additionally, the serial interfaces and some minimal SIM functionality can be verified by sending AT commands to the Enfora Enabler IIIE module. All of these conditions need to be verified at ambient as well as extreme conditions. EDG0308IG001 62 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide As part of integration, each of the following interfaces must be verified: Information SIM Recommendations The maximum line length of the SIM interface is 25.4 cm (10 inches). The Enfora Enabler IIIE module takes care of the signal conditioning As a minimum, an external application with a remote SIM will require a standard SIM carrier. Filter the SIM VCC signal with a 10 uf / 10 V capacitor to help with the line length. Primary and secondary serial Interfaces Reset Interface Audio/Microphone Interface The Enfora Enabler IIIE module uses a 1.8V digital interface. The RS-232 signals must be level-shifted to get standard levels. These signals must be ESD-protected. Resets the Enfora Enabler IIIE module when tied low. Preliminary balancing on Enfora Enabler IIIE module. Maximum length TBD Testing the following parameters verifies the RF parameters that may be affected by such things as RF path loss, power supply noise, and external interference. .Functionality Transmitter Receiver Parameters to be Tested Frequency Error Phase Error PA Ramp Modulation Spectrum RF Power Steps Timing Advance BER Based RX Tests (RXQUAL RXLEV) BER Based Sensitivity Testing the following GSM functionality verifies proper network communication. Functionality Network Function EDG0308IG001 Parameters to be Tested Synchronization and registration Call set-up and call termination (both MT and MO calls) SMS and/or data calls 63 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 12. APPENDIX A - LIMITED WARRANTY 12.1. Scope Enfora warrants to the original purchaser of the product that, for a period of one (1) year from the date of product purchase, the product hardware, when used in conjunction with any associated software (including any firmware and applications) supplied by Enfora, will be free from defects in material or workmanship under normal operation. Enfora further warrants to such original purchaser that, for a period of ninety (90) days from the date of product purchase, any software associated with the product will perform substantially in accordance with the user documentation provided by Enfora, and any software media provided with the product will be free from defects in material or workmanship under normal operation. Enfora does not warrant that (a) the product hardware or any associated software will meet the purchaser’s requirements, (b) that the operation of the product hardware or software will be uninterrupted or error-free, or (c) the product, when integrated in, or combined with, other products or software not supplied by Enfora, will continue to perform substantially in accordance with the user documentation. This limited warranty is only for the benefit of the original purchaser and is not transferable. No other party may act on behalf of such purchaser for the purpose of claiming or exercising any rights or benefits under or in connection with this limited warranty except as may be provided in a written agreement between Enfora and such other party. 12.2. Hardware During the warranty period applicable to the product hardware, Enfora, at its expense and in its sole discretion, will repair or replace the product if it is determined to have a covered hardware defect, provided that the purchaser first notifies Enfora of any such defect, furnishes Enfora with a proof of purchase, requests and obtains a return merchandize authorization (RMA) number from Enfora, and returns the product, shipping charges prepaid, to Enfora under that RMA. If, upon reasonable examination of the returned product, Enfora does not substantiate the defect claimed by purchaser, or determines that the defect is not covered under this limited warranty, Enfora will not be required to repair or replace the product, but may instead reship the product to the purchaser, in which case purchaser shall be responsible for paying Enfora’s usual charges for unpacking, testing, and repacking the product for reshipment to purchaser. Purchaser shall bear the risk of loss or damage in transit to any product returned by purchaser to Enfora, or any returned product not found to be defective or covered under this warranty and reshipped by Enfora to purchaser. In the event Enfora repairs or replaces a defective product, the repaired or replacement product will be covered under this limited warranty for the remainder of the original warranty period on the defective product. If Enfora is unable to repair or replace a defective product, the purchaser’s exclusive remedy shall be a refund of the original purchase price. Any returned and replaced product, or any product for which Enfora has refunded the original purchase price, becomes the property of Enfora. 12.3. Software During the warranty period applicable to the software or its media, Enfora, at its expense, will replace any defective software or media if purchaser gives written notification of the defect to the technical support department at Enfora during the applicable warranty period. Enfora will ship or otherwise transmit the replacement software or media to purchaser, and purchaser shall be responsible for incorporating any replacement software in the product. Enfora shall not have any obligation to provide any software bug fixes, upgrades or new releases except as may be necessary to correct any covered defect of which purchaser notifies Enfora in writing during the applicable warranty period. Enfora, from time to time and in its sole discretion, may make available for download on its website (www.enfora.com) certain software bug fixes, upgrades or new releases for the product. The purchaser should periodically visit such website to determine whether any such bug fixes, upgrades or new releases have become available. Download and use of any such bug fixes, upgrades or new EDG0308IG001 64 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide releases is subject to all of the applicable terms and conditions of Enfora’s technical support policy as posted and updated on its website. Exceptions and Disclaimers Enfora shall have no obligation under this limited warranty for (a) normal wear and tear, (b) the cost of procurement of substitute products or (c) any defect that is (i) discovered by purchaser during the warranty period but purchaser does not notify or request an RMA number from Enfora, as required above, until after the end of the warranty period, (ii) caused by any accident, misuse, abuse, improper installation, handling or testing, or unauthorized repair or modification of the product, (iii) caused by use of any software other than any software supplied by Enfora, or by use of the product other than in accordance with its documentation or (iv) the result of electrostatic discharge, electrical surge, fire, flood or similar causes. Unless otherwise provided in a written agreement between the purchaser and Enfora, the purchaser shall be solely responsible for the proper configuration, testing and verification of the product prior to deployment in the field. ENFORA’S SOLE RESPONSIBILITY AND PURCHASER’S SOLE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE TO REPAIR OR REPLACE THE PRODUCT HARDWARE, SOFTWARE OR SOFTWARE MEDIA (OR IF REPAIR OR REPLACEMENT IS NOT POSSIBLE, OBTAIN A REFUND OF THE PURCHASE PRICE) AS PROVIDED ABOVE. ENFORA EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF NONINFRINGEMENT, MERCHANTABILITY, SATISFACTORY PERFORMANCE AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL ENFORA BE LIABLE FOR ANY INDIRECT, SPECIAL, EXEMPLARY, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING WITHOUT LIMITATION LOSS OR INTERRUPTION OF USE, DATA, REVENUES OR PROFITS) RESULTING FROM A BREACH OF THIS WARRANTY OR BASED ON ANY OTHER LEGAL THEORY, EVEN IF ENFORA HAS BEEN ADVISED OF THE POSSIBILITY OR LIKELIHOOD OF SUCH DAMAGES. 12.4. Other Considerations Some jurisdictions may require a longer warranty period than specified above and, accordingly, for products sold in those jurisdictions the applicable warranty period shall be extended as required under the laws of those jurisdictions. Furthermore, some jurisdictions may not allow the disclaimer of implied warranties or the exclusion or limitation of incidental or consequential damages, so the above disclaimer, limitation or exclusion may not apply to products sold in those jurisdictions. This limited warranty gives the purchaser specific legal rights and the purchaser may have other legal rights that vary from jurisdiction to jurisdiction. In some instances, certain aspects of the product warranty may also be covered in a separate written agreement between Enfora and the distributor or reseller, if any, from whom purchaser purchased the product. That agreement may provide, for example, a different product return procedure that may also be available to purchaser (e.g., the product may be returned to Enfora through that distributor or reseller). Governing Law This limited warranty shall be governed by the laws of the State of Texas, United States of America, without regard to conflict of laws principles. This limited warranty shall not be governed in any respect by the United Nations Convention on Contracts for the International Sale of Goods. EDG0308IG001 65 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 13. APPENDIX B - Regulations and Compliance This section summarizes the responsibilities and actions required of manufacturers and integrators who incorporate OEM versions of the Enfora Enabler IIIE module into their products. In certain situations and applications, these products will require additional FCC, CE, GCF, PTCRB or other regulatory approvals prior to sale or operation. Appropriate instructions, documentation and labels are required for all products. For more information concerning regulatory requirements, please contact Enfora. 13.1. GCF/PTCRB Approval (Formerly FTA) The Enfora Enabler IIIE module is type approved in accordance with the requirements of and through the procedures set forth by the GSM industry association. The relevant conformance specification is 3GPP TS 51010-1. Any OEM changes in the SIM interface, antenna port, software or the physical makeup of the unit may require an incremental FTA to ensure continued compliance with the abovementioned standard. For more information concerning type approval, please contact Enfora. 13.2. Electromagnetic Compatibility (EMC) and Safety Requirements The Enfora Enabler IIIE module has been tested and approved for application in the United States of America (US) and the European Union (EU). The compliance details for each of these markets follow. For other markets, additional or alternative regulatory approvals may be required. Always ensure that all rules and regulations are complied with in every country that the OEM application is to be operated. Regardless of the country or market, the OEM must comply with all applicable regulatory requirements. 13.3. EMC/Safety Requirements for the USA Compliance to the US rules and regulations falls under two categories: • Radio approvals: Federal Communications Commission (FCC) • Transmitter: FCC Rules, Part 22 & 24 • Unintentional emission: FCC Rules, Part 15 Although the Enfora Enabler IIIE module has been authorized by the FCC and listed as a component by an NRTL, products and applications that incorporate the Enfora Enabler IIIE module will require final verification of EM emission and product safety approval. Note: Particular attention should be made to the following statements regarding RF Exposure: EDG0308IG001 66 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 13.4. Human Exposure Compliance Statement GSM0308 GSM/GPRS Module Enfora certifies that the Enfora Enabler IIIE 850/900/1800/1900 MHz GSM Radio Module (FCC ID: MIVGSM0308) complies with the RF hazard requirements applicable to broadband PCS equipment operating under the authority of 47 CFR Part 24, Subpart E and Part 22 of the FCC Rules and Regulations. This certification is contingent upon installation, operation and use of the Enfora Enabler IIIE module and its host product in accordance with all instructions provided to both the OEM and end user. When installed and operated in a manner consistent with the instructions provided, the Enfora Enabler IIIE module meets the maximum permissible exposure (MPE) limits for general population / uncontrolled exposure at defined in Section 1.1310 of the FCC Rules and Regulations. Note: Installation and operation of this equipment must comply with all applicable FCC Rules and Regulations, including those that implement the National Environmental Policy Act of 1969 (Part 1, Subpart I), with specific regard to antenna sitting and human exposure to radio frequency radiation. For further guidance, consult the FCC Rules, a certified FCC test house, or Enfora. 13.5. Compliance with FCC Regulations The Federal Communications Commission (FCC) is the agency of the Federal Government that oversees all non-governmental radio frequency transmitters that operate within the United States. Unintentional emissions from digital devices are regulated by Part 15 of the FCC Rules and Regulations, which distinguishes between the environments in which these devices may operate. Intentional radiators operating as a GSM-1900 radio transmitter are regulated under Part 22 & 24, Subpart E—Broadband PCS of the FCC Rules and Regulations. EDG0308IG001 67 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 13.6. Unintentional Radiators, Part 15 Equipment designated as Class A is intended for use in a commercial, industrial or business environment. The Enfora Enabler IIIE module has been tested and found to comply with the limits for a Class A digital device and can be integrated into equipment or applications intended for use in commercial, industrial or business environments. The following statement must be included in the user manual for such products: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Equipment intended for use in a residential environment (not-withstanding use in commercial, industrial or business environments) is designated as Class B. The Enfora Enabler IIIE module has been tested and found to comply with the limits for a Class B digital device and can be integrated into equipment or applications intended for use in residential environments. The following statement must be included in the user manual for such products: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. 13.7. Intentional Radiators, Part 22 & 24 Products incorporating the Enfora Enabler IIIE transceiver operate as Personal Communications Services (PCS) devices under the authority of Part 22 & Part 24, Subpart E—Broadband PCS, of the FCC Rules and Regulations. All such transmitters must be authorized by the FCC through its Certification process, as detailed in Part 2, Subpart J - Equipment Authorization Procedures. Through the Certification process, the FCC verifies that the product complies with all applicable regulatory and technical requirements, including those that address human exposure to radio frequency radiation. In general, radio frequency transmitters cannot be sold or operated in the US prior to FCC approval. EDG0308IG001 68 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 13.8. Instructions to the Original Equipment Manufacturer (OEM) To comply with the requirements of the National Environmental Policy Act (NEPA) of 1969, operation of an FCC-regulated transmitter may not result in human exposure to radio frequency radiation in excess of the applicable health and safety guidelines established by the FCC. Further information on RF exposure issues may be found in the FCC's Office of Engineering and Technology (OET) Bulletin Number 65, "Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields" and Supplement C, "Additional Information for Evaluating Compliance of Mobile and Portable devices with FCC Limits for Human Exposure to Radio Frequency Emissions.” Both of these documents are available via the Internet at the OET web site: http://www.fcc.gov/oet The Enfora Enabler IIIE products are GSM radio transceivers, which operate under the authority of 47 CFR Part 24, Subpart E and Part 22 of the FCC Rules and Regulations. When installed and operated in accordance with the instructions provided in this manual, these devices comply with current FCC regulations regarding human exposure to radio frequency radiation. The following installation and operation restrictions apply to all Enfora Enabler IIIE products: • This device may only be used in fixed and mobile applications. • Portable applications, as defined by the FCC, are prohibited. • The use of this device for desktop and other applications where the antenna can easily be relocated are considered by the FCC to be mobile applications. • A separation distance of at least 20 cm (7.87 inches) between the antenna and the body of the user and other persons must be maintained at all times • In FIXED applications, antenna gain is limited to a maximum of 7 dBi, with a corresponding Equivalent Isotropic Radiated Power (EIRP) of 37 dBm / 5 W. • In MOBILE applications, antenna gain is limited to a maximum of 2 dBi, with a corresponding EIRP of 33 dBm / 2 W. • End products must provide instructions to ensure compliance with radio frequency radiation exposure requirements. • A warning label visible to all persons exposed to the antenna and identical to that described in this manual must be displayed on or next to the antenna. • Separate FCC approval for RF exposure compliance is required for end products that do not meet these conditions. Antenna gain is defined as gain in dBi (dB referenced to an isotropic radiator) minus cabling loss. EDG0308IG001 69 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide Note: Additional care must be taken by the installer and/or user of the Enfora Enabler IIIE products to ensure proper antenna selection and installation. Adherence to the above conditions is necessary to comply with FCC requirements for safe operation regarding exposure to RF radiation. Depending upon the application and type of product into which the Enfora Enabler IIIE module has been incorporated, specific OEM actions and responsibilities required to meet these conditions vary. However, in all cases the primary concern is to ensure compliance with current FCC guidelines and regulations that limit human exposure to radio frequency radiation. Definitions For the purpose of determining compliance with current FCC rules addressing human exposure to radio frequency radiation, the FCC has established the following three categories of transmitting devices: EDG0308IG001 • Portable Devices – devices where the antenna is located within 20 cm (7.87 inches) of any person, including the user, if applicable. Portable devices operating under the authority of Part 22 or 24 (broadband PCS) are limited to a maximum of 2 W EIRP. • Mobile Devices – devices designed to be used in other than fixed locations and generally such that the antenna is located at a minimum of 20 cm (7.87 inches) from any person, including the user, if applicable. Mobile devices operating under the authority of Part 22 or 24 (broadband PCS) are limited to a maximum of 2 W EIRP. • Fixed devices – devices in which the antenna, either integral to the product or remotely located, is physically secured at one location and is not able to be easily moved to another location. The antenna for a fixed device is mounted on an outdoor permanent structure with a minimum separation distance of 2 meters (79 inches) 70 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 13.8.1. OEM Responsibilities for All Products Containing the Enabler IIIE module In addition to any other regulatory requirements, OEMs and integrators must include or provide the following information, instructions, warnings and labels with any device or product into which the Enfora Enabler IIIE GSM1900 GSM transceiver has been incorporated: Information Detailed Operating Instructions for ensuring compliance with current FCC guidelines which limit human exposure to radio frequency radiation Antenna Avoidance Label Human Exposure Compliance Statement Description The OEM must provide an operating/installation manual with the final product which clearly indicates that these operating conditions and restrictions must be observed at all times to ensure compliance with current FCC guidelines which limit human exposure to radio frequency radiation. 20 cm (7.87 inch) separation distance between the antenna and all persons must be maintained at all times for all fixed and mobile products and applications Portable devices and applications are prohibited unless such devices and products are specifically authorized by the FCC Maximum antenna gain is limited to 2 dBi* in mobile products and applications For fixed applications (2 meter separation) the antenna gain can be as much as 26 dBi. Modifications and/or additions to the Enfora Enabler IIIE GSM transceiver, including use of antennas with higher gain than those authorized by the FCC, are prohibited *dBi = antenna gain in dB relative to an isotropic radiator Attach the following warning label directly to or displayed next to the WARNING antenna. Furthermore, this label must To comply with FCC RF exposure be visible to and easily readable by all requirements, a separation distance of 20 cm persons in the immediate vicinity of the (7.87”) or more must be maintained between antenna this antenna and all persons Include the following statement in the instruction / operation manual. EDG0308IG001 71 Enfora certifies that the Enfora Enabler IIIE ™ MHz GSM Radio Module (FCC ID: MIVGSM0308) complies with the RF hazard requirements applicable to broadband PCS equipment operating under the authority of 47 CFR Part 22 or Part 24, Subpart E of the FCC Rules and Regulations. This certification is contingent upon installation, operation and use of the Enfora Enabler IIIE module and its host product in accordance with all instructions provided to both the OEM and end used. When installed and operated in a manner consistent with the instructions provided, the Enfora Enabler IIIE module meets the maximum permissible exposure (MPE) limits for general population / uncontrolled exposure at defined in Section 1.1310 of the FCC Rules and Regulations. Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 13.8.2. Specific OEM Responsibilities for Portable Products and Applications Each device or product, into which the Enfora Enabler IIIE PCS-1900 GSM transceiver has been incorporated, and which is intended to be used in an application that meets the definition of "portable" MUST be separately authorized by the FCC for the purposes of determining compliance with current FCC guidelines limiting human exposure to radio frequency radiation. Portable devices must be evaluated for RF exposure based on Specific Absorption Rate (SAR) limits; further information on such evaluations are available from the FCC via the Internet. 13.8.3. Specific OEM Responsibilities for Mobile Products and Applications Separate or additional FCC approvals are NOT required for devices or products, into which the Enfora Enabler IIIE PCS-1900 GSM transceiver has been incorporated, that are used in applications that meet the definition of "mobile." For all end products, the OEM or integrator must provide instructions, warnings and labels to ensure that the product complies with current FCC guidelines limiting human exposure to radio frequency radiation. Current FCC regulations limit the EIRP of mobile devices to 2 W. Because the nominal RF output power of the Enfora Enabler IIIE GSM1900 GSM transceiver is 1.0 W (31 dBm), antenna gain for mobile products and applications cannot exceed 2 dBi. 13.8.4. Specific OEM Responsibilities for Fixed Products and Applications Separate or additional FCC approvals are not required for devices or products, into which the Enfora Enabler IIIE GSM transceiver has been incorporated, that are used in applications that meet the definition of "fixed.” For all end products, the OEM or integrator must provide the instructions, warnings and labels to ensure that the product complies with current FCC guidelines limiting human exposure to radio frequency radiation. Separate or additional FCC approvals are required for devices or end products used in fixed applications where antenna gain in excess of 7dBi is desired. EDG0308IG001 72 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 13.9. EMC/Safety Requirements for the Countries of the European Union (EU) The European Union (EU) is comprised of fifteen countries that follow a harmonized set of standards, utilizing the CE mark as a uniform mark of acceptance. The member countries are: • • • • • • • • • • • • • • • • • • • • • • • • 13.10. Austria Belgium Cyprus Czech Republic Denmark Estonia Finland France Germany Greece Hungary Ireland Italy Latvia Lithuania Luxembourg The Netherlands Poland Portugal Slovakia Slovenia Spain Sweden United Kingdom EMC/Safety Requirements for Other Countries In most other countries that have not been listed above there are similar rules and regulations that must be met for importing the Enfora Enabler IIIE module. Each may require a different mark of approval (for example, the CB Scheme) as an acceptance requirement. For each of these cases the country should identified, and the appropriate steps should be taken to meet the requirements set forth in the intended market. EDG0308IG001 73 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 14. APPENDIX C - Glossary and Acronyms API App Application AT Command Set BER Bit Error Rate CMUX CPE Customer Premise Equipment CSD Circuit Switched Data dBi DCE Data Communications Equipment DCS Digital Cellular System DTE Data Terminal Equipment EFR Enhanced Full Rate EIR Equipment Identity Register EIRP Equivalent Isotropic Radiated Power EMC Electromagnetic Compatibility ESD Electrostatic Discharge EU European Union FTA Full Type Approval GPRS General Packet Radio Service GSM Global System for Mobile Communications HLR Home Location Register EDG0308IG001 Application Programming Interface. Refers to the Application which sends or receives commands/responses from the Enfora Enabler IIIE Module Commands issued by intelligent device to a modem to perform functions, such as to initiate call, to answer call, or to transmit data. Bit Error Rate Multiplexer protocol that operates between an MS and a TE and allows a number of simultaneous sessions over a normal serial asynchronous interface A terminal in fixed location on the customer’s premises. Data link from a terminal through the network allowing real-time, duplex connectivity at 9600 bytes/second. Decibels referenced to an isotropic radiator Data Communications Equipment A collection of services and capabilities providing flexibility of access and mobility through a combination of wireless and wire-line networks, utilizing the 1800 MHz bandwidth. Data Terminal Equipment Voice (vocoder) compression algorithms which offer the highest quality voice communication. A database used to store International Mobile Equipment Identity (IMEI) of a locally issued terminal. In a given direction, the gain of a transmitting antenna multiplied by the net power accepted by the antenna from the connected transmitter. The ability of a device to function satisfactorily in its electromagnetic environment without inducing intolerable disturbance to that environment (or to other devices) Static electricity that can damage electronic equipment. An organization of 15 European states whose purpose is to organize relations between the Member States and between their peoples. GSM Full Type Approval Standard for packet communications utilizing Global Standard for Mobility (GSM) infrastructure. Standard for digital communications. Allows consistent communications in various parts of the world despite variations in RF spectrum allocations. Transferring the SIM (see below) permits users to roam by changing terminal equipment. Stores the identity and user data for all subscribers belonging to the area of the related MSC. 74 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide IMEI International Mobile Equipment Identity IMSI International Mobile Subscriber Identification Ki A unique number for each GSM Terminal tracked by the GSM operators in their Equipment Identity Register (EIR) database. MO Mobile Originated MT Mobile Terminated MSC Mobile Switching Center Non-Transparent Mode Any GSM/GPRS service originated at the mobile terminal. NRTL Nationally Recognized Test Laboratory OEM PA Packet PCS PDA PDU PPP SIM SMS SMSC SUPL UDP EDG0308IG001 A unique number identifying the subscriber stored in the SIM card. Number is used in conjunction with the network for call routing. A secret code used in authentication and encryption by the terminal. Any GSM/GPRS service originated from or routed through the network and sent to the mobile terminal. The central switch of the GSM network. Performs call routing, collects call detail records for billing, and supervises system operations. Delivers a constantly low error rate but with a non-guaranteed throughput or delay. The Non-Transparent service provides a performance that is closest to using a modem over a fixed PSTN line. OSHA-approved Nationally Recognized Testing Laboratory Original Equipment Manufacturer. Power Amplifier. A collection of data transmitted over a digital network in a burst. Personal Communication Services. Personal Digital Assistant. Packet Data Unit. Point-To-Point Protocol. Subscriber Identity Module. Short Message Service. Short Message Service Center. Secure User Plane Location User Datagram Protocol. 75 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 15. APPENDIX D – Tables and Figures FIGURES Figure 1 - Example of good ground plane for GSM modules ..................................................................... 14 Figure 2 - Example of a POOR RF Thermal Relief..................................................................................... 15 Figure 3 - Example of a GOOD RF Thermal Relief .................................................................................... 16 Figure 4 - Example of Vbat Voltage Droop ................................................................................................. 17 Figure 5 - Example of GOOD Vbat layout................................................................................................... 18 Figure 6 - Audio Reference Design Schematic........................................................................................... 19 Figure 7 – Side View and Top View............................................................................................................ 23 Figure 8 – Side View and Top View............................................................................................................ 24 Figure 9 – Module Mounting ....................................................................................................................... 25 Figure 10 - Shield Mounting Pads............................................................................................................... 26 Figure 11 - Host Pads for Board-To-Board RF Connector ......................................................................... 27 Figure 12 – Power Control Switch .............................................................................................................. 35 Figure 13 - External Power Control Signal (no external processor) ........................................................... 36 Figure 14 - Power Control Signal (using external processor) ..................................................................... 37 Figure 15 - Ring Indicate Timing................................................................................................................. 43 Figure 16 - Remote SIM Interface............................................................................................................... 51 Figure 17 – Hyper Terminal Definition ........................................................................................................ 57 Figure 18 - COM Port Settings.................................................................................................................... 58 EDG0308IG001 76 Draft – 03/07/2008 Enfora Enabler IIIE Modem Integration Guide 16. APPENDIX E - Contacting Enfora For technical support and customer service dealing with the modem itself, contact the company where you purchased the product. If you purchased the product directly from Enfora, visit the SUPPORT page on the Enfora website: http://www.enfora.com/support_newissue.asp EDG0308IG001 77 Draft – 03/07/2008
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Tagged PDF : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 (Windows) Company : Enfora, LLP Source Modified : D:20080307184511 Create Date : 2008:03:07 12:45:54-06:00 Creator Tool : Acrobat PDFMaker 7.0.7 for Word Modify Date : 2008:03:07 12:48:24-06:00 Metadata Date : 2008:03:07 12:48:24-06:00 Document ID : uuid:3bdffbcf-f288-4efc-81e1-70de36faa0de Instance ID : uuid:fe8cdf67-276d-4d0e-9854-6028d3bebf82 Version ID : 6 Format : application/pdf Title : Enabler II-G Assiste GPS Integration Guide Creator : Matt Glover Subject : Headline : Page Count : 82 Page Layout : OneColumn Author : Matt GloverEXIF Metadata provided by EXIF.tools