Nutone La 107 Users Manual 83527~LA 2 PGS
LA-107 LA107ins83527_ca
LA-107 to the manual 037b2799-3748-44b8-b9f2-edd3f8e7967f
2015-02-03
: Nutone Nutone-La-107-Users-Manual-466673 nutone-la-107-users-manual-466673 nutone pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
INSTALLATION INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS! Viking Door Chime INSTALLING THE WIRING MODEL: LA-107 SERIES • For use with either a transformer or batteries 1. Use standard bell/chime wire (20 gauge, two-conductor). 2. Run wires as shown in Figure 2 for installation using transformer. 3. Run wires as shown in Figure 3 for installation using batteries. LOCATION MOUNTING CHIME BASE TRANSFORMER: Mount a 10 or 16-volt transformer to a conveniently located junction box. Attic location is not recommended. For best performance, a 16 volt transformer is recommended. Refer to Figure 4. 1. At chime location, cut a 1" diameter hole (for pushbutton and transformer wiring) in the wall. 2. Pull wiring through two holes in chime base. 3. Use two provided screws to mount chime base to wall. Make sure keyhole mounting hole is at top. PUSHBUTTON: The chime is designed for two-note operation. Select pushbutton locations at front and rear (or side) doors. Do not use lighted pushbuttons with battery-operated chime. NEW INSTALLATION USING BATTERIES FRONT DOOR PUSHBUTTON NEW INSTALLATION FOR ONE DOOR OR TWO DOORS SUPPLY WIRE DO NOT OIL C - BAT. COMMON T - TRANSFORMER F - FRONT DOOR PB R - REAR DOOR PB “D” SIZE BATTERY R C F T CHIME BASE TERMINAL BOARD “D” SIZE BATTERY WIRES TO CHIME REAR DOOR PUSHBUTTON “D” SIZE BATTERY Disconnect house power until installation is complete. All wiring must comply with local codes. 1. Use a NuTone transformer (16 volts, 10 watts). 2. Refer to Figure 1. Mont transformer to a conveniently located junction box. Do not mount transformer in attic. 3. Use approved wire connectors to connect supply wires to transformer leads: white to white; black to black. “D” SIZE BATTERY INSTALLING TRANSFORMER FIGURE 3 FIGURE 1 CHIME BASE REPLACEMENT OR NEW INSTALLATION USING TRANSFORMER MAKE SURE KEYHOLE MOUNTING HOLE IS AT THE TOP FRONT DOOR PUSHBUTTON REAR DOOR PUSHBUTTON 120vAC TRANSFORMER 16 VOLT 10VA OR 10 VOLT 5VA CHIME BASE TERMINAL BOARD DO NOT OIL C - BAT. COMMON T - TRANSFORMER F - FRONT DOOR PB R - REAR DOOR PB R C F T FOR ONE DOOR OR TWO DOORS TO 120 HOUSE WIRING FIGURE 2 PUSHBUTTON AND TRANSFORMER WIRING FIGURE 4 WIRING CONNECTIONS REPLACEMENT INSTALLATION 1. Use wire nuts to make connections. Insulate all connections with electrical tape. 2. INSTALLATION USING TRANSFORMER. Refer to Figure 2. Connect pushbutton and transformer wires to terminal screws marked Front, Transformer, and Rear. 3. INSTALLATION USING BATTERIES. Refer to Figure 3. Connect pushbutton wires to terminal screws marked Front, Common, and Rear. 1. Turn off house power until installation is complete. 2. Remove cover from existing chime and disconnect wires from terminal screws. Label all wires (Front, Transformer, Rear) as you remove them. NOTE: Any additional wires (for example: common or side) should be individually capped with wire nuts or sealed with electrical tape and pushed back into the wall cavity. These wires are not needed. 3. Remove existing chime base from wall. 4. Pull wires through holes in new chime base. 5. Use provided screws to mount base to wall. 6. Connect wires to terminal screws marked Front, Transformer, and Rear on the chime base. 7. Place chime cover securely over the base. 8. Restore house power to chime. WIRING HINTS 1. Carefully fasten wiring to wall studs and ceiling joists. Avoid short circuits caused by staples or clops cutting through the wiring's insulation. 2. Loop wire around terminal screws. 3. When connecting more than one wire to a single terminal screws, twist the wires together before looping them around the terminal screw. 4. Make sure all terminal screws are tightened securely. CHIME COVER MOUNTING TAB MOUNTING SLOT CHIME BASE BATTERY INSTALLATION 1. Install four (4) “D” size batteries as shown in Figure 4. 2. For longer life, alkaline batteries are recommended. ATTACHING CHIME COVER 1. Place cover over base. 2. Refer to Figure 5. Secure cover by placing mounting tab into slot at back of base. FIGURE 5 One Year Limited Warranty WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one (1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by NuTone), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. WARRANTY SERVICE: To qualify for warranty service, you must (a) notify NuTone at the address stated below or telephone 1/800-543-8687, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. Date of Installation Builder or Installer Model No. and Product Description IF YOU NEED ASSISTANCE OR SERVICE: For the location of your nearest NuTone Independent Authorized Service Center: Residents of the contiguous United States Dial Free 1-800-543-8687 Please be prepared to provide: Product model number • Date and Proof of purchase • The nature of the difficulty Residents of Alaska or Hawaii should write to: NuTone Inc. Attn: Department of National Field Service, 4820 Red Bank Road, Cincinnati Ohio 45227-1599. Residents of Canada should write to: Broan-NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9. Rev. 03/2001 Product specifications subject to change without notice. 4820 Red Bank Road, Cincinnati, Ohio 45227 Printed in U.S.A., Rev. 3/01 Part No. 83527
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2001:05:15 16:29:02 Producer : Acrobat Distiller 4.0 for Macintosh Author : Heather Creator : QuarkXPress¨: LaserWriter 8 8.3.4 Title : 83527~LA-107 -2 PGS Modify Date : 2001:05:15 16:29:19Z Page Count : 2EXIF Metadata provided by EXIF.tools