OKIN Refined Electric Technology CB1342 Control Box User Manual CB1342 x

OKIN Refined Electric Technology Co., Ltd. Control Box CB1342 x

User Manual

Download: OKIN Refined Electric Technology CB1342 Control Box User Manual CB1342 x
Mirror Download [FCC.gov]OKIN Refined Electric Technology CB1342 Control Box User Manual CB1342 x
Document ID3571325
Application IDucleLiPL0DHZ7DGzwwpuaQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize44.16kB (552016 bits)
Date Submitted2017-09-20 00:00:00
Date Available2017-09-20 00:00:00
Creation Date2017-08-25 14:37:51
Producing SoftwareAcrobat Distiller 11.0 (Windows)
Document Lastmod2017-09-20 13:46:30
Document TitleMicrosoft Word - CB1342_User Manual.docx
Document CreatorPScript5.dll Version 5.2.2
Document Author: baclsh93

Issue department:Bedding Division
Product Function
instruction
CB.13.42.02
Date:
Author:
No:CB1342
Version:
1.1
Page 2 of 5
1. Function Picture
1.
2017-08-23
Kyle
Process of test
1.1. HEAD MOTOR
Connect to head actuator,control by remote single:
Click head up button on the remote, head actuator moves out, stop when released;
Click head down button,head actuator moves in, stop when released;
This function takes effect only by pressing the corresponding button on the remote.
1.2. FOOT MOTOR
Connect to foot actuator,control by remote single:
Click foot up button,foot actuator moves out,stop when released;
Issue department:Bedding Division
Product Function
instruction
CB.13.42.02
Date:
Author:
2017-08-23
Kyle
No:CB1342
Version:
1.1
Page 3 of 5
Click foot down button,foot actuator moves in,stop when released;
This function takes effect only by pressing the corresponding button on the remote.
1.3. Tilt MOTOR
Connect to head actuator,control by remote single:
Click Tilt up button on the remote, head actuator moves out, stop when released;
Click Tilt down button,head actuator moves in, stop when released;
This function takes effect only by pressing the corresponding button on the remote.
1.4. Lumber MOTOR
Connect to foot actuator,control by remote single:
Click Lumber up button,foot actuator moves out,stop when released;
Click Lumber down button,foot actuator moves in,stop when released;
This function takes effect only by pressing the corresponding button on the remote.
1.5. Massage
Connect to head & Foot massage,control by remote:
Click head massage + button,head massage strengthens by one level;
Click head massage ‐ button,head massage weakenby one level;
This function takes effect only by pressing the corresponding button on the remote.
1.6. Test for underbed light
Click button of underbed light, turns on( or turns off ) the underbed light, switch the status once when click once;
This function takes effect only by pressing the corresponding button on the remote.
1.7. SYNC port
Connect with the same other Control box or Other accessories;
Issue department:Bedding Division
Product Function
instruction
CB.13.42.02
Date:
Author:
2017-08-23
Kyle
No:CB1342
Version:
1.1
Page 4 of 5
1.8. Power LED & PAIRING LED
Power supply for control box, PAIRING LED of control box is blue, POWER LED is green。
1.9. Power
Connect to the 29V DC;
1.10. RESET button
Press and hold the RESET button(Corresponding Pair
button),the Head, Foot actuators will moves to lower position. Long press is reset.
1.11. Pair Function
Double click RESET button,pairing LED turns on,the control box enters into mode of code paring;
Press and hold the paring LED of Remote, the backlight of paring LED flashes, the backlight of remote flashes, the
remote enters into mode of code paring;
The backlight of paring LED of remote stops flashing, and the paring led of control box turns off, it indicates that
the code paring is successful;
If fails, repeat all the processes above;
1.12. FLAT function
Press and release the FLAT button on remote
,the head and foot actuators moves to lower position(when the
actuator is free, can turn off the vibration motor and turn off the indicator light when press once ),stop when press
any buton;
This function takes effect only by pressing the corresponding button on the remote.
1.13. ZERO G position function
Press and release ZERO G button on remote,the head and foot actuator moves to preset memory position,stop
when press any button;
This function takes effect only by pressing the corresponding button on the remote.
Issue department:Bedding Division
Product Function
instruction
CB.13.42.01
Date:
Author:
2017-08-23
Kyle
No:CB1342
Version:
1.1
Page 5 of 5
FCC:
Any Changes or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
IC RSS warning
This device complies with Industry Canada licence‐exempt RSS standard (s). Operation is subject to the following
two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference,including interference that may cause undesired operation of the device.
ISED RSS Warning:
This device complies with Innovation,Science and Economic Development Canada licenceexempt
RSS standard(s). Operation is subject to the following two conditions: (1) this device
may not cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'ISED applicables aux appareils radio
exempts de licence.
L'exploitation est autorisée aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement.
JLDP.14.027.000
JLDP.05.032.000
R5.216.01.015C
JLDP.10.023.000
R5.217.01.016
R5.504.01.250
R5.113.00.011
R5.413.01.005
RF.30.22.03
CB.13.42.01
R5.410.01.009
JLDQ.9.001.130C
JLDQ.16.228.31
JLDQ.16.263.84
B.11964
B.15055
NO.
product name
Head Motor
Foot Motor
Lumbar Motor
Tilt Motor
Massage Motor
Massage Motor Cable
Control Box
Power Supply
cord of Power
10
Power Cord AC
11
Y-Cable
12 Patch cord of LED strip/LED
13
Underbed lighting /LED
14
USB Chager/ USB
15
Double USB socket
16
22keys Remote Model /22
Product code
B.15055
B.11964
JLDQ.16.263.84
JLDQ.16.228.31
JLDQ.9.001.130C
R5.410.01.009
CB.13.42.01
JLDP.10.023.000
R5.217.01.016
R5.504.01.250
R5.216.01.015C
R5.413.01.005
R5.113.00.011
JLDP.05.032.000
JLDP.14.027.000
RF.30.22.03
number
S750 V1.3
20 17 0 7 31
John

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : baclsh93
Create Date                     : 2017:08:25 14:37:51+08:00
Modify Date                     : 2017:09:20 13:46:30-07:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2017:09:20 13:46:30-07:00
Format                          : application/pdf
Title                           : Microsoft Word - CB1342_User Manual.docx
Creator                         : baclsh93
Producer                        : Acrobat Distiller 11.0 (Windows)
Document ID                     : uuid:79cadb21-d97c-4c45-b628-538fc31b8899
Instance ID                     : uuid:a7009333-c6cb-4bde-a7ed-fcd04f0a9e79
Page Count                      : 5
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PCU-CB1342

Navigation menu