OKIN Refined Electric Technology JLDP03045 Control Box User Manual

OKIN Refined Electric Technology Co., Ltd. Control Box Users Manual

Users Manual

Download: OKIN Refined Electric Technology JLDP03045 Control Box User Manual
Mirror Download [FCC.gov]OKIN Refined Electric Technology JLDP03045 Control Box User Manual
Document ID3460435
Application IDkURBEENVjXrHyCe6z2RZyw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize134.94kB (1686770 bits)
Date Submitted2017-07-11 00:00:00
Date Available2017-07-11 00:00:00
Creation Date2017-06-23 14:37:30
Producing SoftwareAcrobat Distiller 11.0 (Windows)
Document Lastmod2017-07-11 14:18:32
Document TitleMicrosoft Word - JLDP.03.045.000产品说明书&测试指导.docx
Document CreatorPScript5.dll Version 5.2.2
Document Author: baclsh67

Date:
Operating manual
JLDP.03.045.000/JLDP.03.021/JLDP.03.053
1.
No:JLDP.03
Version:
1.1
Page 1 of 7
Product
Figure2
Figure1
Product model:Control Box
Model: JLDP.03.045.000 (Figure1)
Series Model: JLDP.03.021;JLDP.03.053((Figure2)
SW version:V1.1
Product certification:D.N/A
1.1. test configuration list
Name
Head motor
Foot motor
Synchronous line
ACPower cord
DCPower cord
SMPS
Under bed light
Vibrating motor
Made by:
ORE Product model
B11359
B11360
R5.408.00.002
R5.502.01.400
R5.217.01.120
JLDP.10.014.000
R5.113.00.010
JLDQ.9.001.130B
Checked by:
1/7
2016-11-2
Quantity
Confirmed by:
Date:
Operating manual
JLDP.03.045.000/JLDP.03.021/JLDP.03.053
2.
2016-11-2
No:JLDP.03
Version:
1.1
Page 2 of 7
operation process
2.1. pairing
Step1: Push the DIP Switch on the remote control to a certain position(different from the
position on the other remote controls paired with the near other control boxes. ) and put in the
batteries.
Step2: Power on the control box.
Step3: Press and hold the pairing Tact Switch on the control box with the pairing LED turning on
until the pairing LED on the control box turns off ;then release the Tact Switch and the pairing Led
begins flashing that indicates the control box is pending to pair.
Step4: Press and hold simultaneously the Head‐Up button and the Foot‐Up button on the remote
control until backlight LED flashing. Release the two buttons and the backlight LED continue
Made by:
Checked by:
2/7
Confirmed by:
Date:
Operating manual
JLDP.03.045.000/JLDP.03.021/JLDP.03.053
2016-11-2
No:JLDP.03
Version:
1.1
Page 3 of 7
flashing and search the control box pending to pair where the pairing Led is flashing, once both
the backlight on the remote control and the pairing Led on the control stop flashing, the pairing
operating is completed. To test if the pairing successfully, press the Head‐up or Head‐down or
Foot‐up or Foot‐down button,as so on, related to the actuators , if the click sound from the
relays in the control box can be heard that means it is successful. Otherwise, repeat the all above
steps.
2.2. Head Up
Press and hold the HEAD UP button, the Head actuator will go up. Stop when released.
2.3. Head Down
Press and hold the HEAD DOWN button, the Head actuator will go down. Stop when released.
2.4. Foot Up
Press and hold the FOOT UP button, the Foot actuator will go up. Stop when released.
2.5. Foot Down
Press and hold the FOOT DOWN button, the Foot actuator will go down. Stop when released.
2.6. FLAT
Click the FLAT button, the Head and Foot actuator will start up simultaneously and keep running
until arriving to their low limited switches,. Running can be stopped by clicking any button.
2.7. ZG
Click the ZG button, the Head and Foot actuator will start up simultaneously and keep running
until arriving to the zero gravity position. Running can be stopped by clicking any button.
Made by:
Checked by:
3/7
Confirmed by:
Date:
Operating manual
JLDP.03.045.000/JLDP.03.021/JLDP.03.053
2016-11-2
No:JLDP.03
Version:
1.1
Page 4 of 7
2.8. TV
Click the TV button, the Head and Foot actuator will start up simultaneously and keep running
until arriving to the TV gravity position. Running can be stopped by clicking any button.
2.9. MEMORY A
Click the MEMORY A button, the Head and Foot actuator will start up simultaneously and keep
running until arriving to the MEMORY A gravity position. Running can be stopped by clicking any
button.
2.10. MEMORY B
Click the MEMORY B button, the Head and Foot actuator will start up simultaneously and keep
running until arriving to the MEMORY B gravity position. Running can be stopped by clicking any
button.
2.11. QUIET SLEEP
Click theQUIET SLEEP button, the Head and Foot actuator will start up simultaneously and keep
running until arriving to the QUIET SLEEP gravity position. Running can be stopped by clicking any
button
2.12. set special positions(ZG, TV,MEMORY A, MEMORY B, QUIET SLEEP)
The procedure to set these special positions is below:
Step 1: Click the FLAT button to flat the bed;
Step 2: Adjust the four actuators to the desired positions by pressing the corresponding buttons;
Step 3: Press and hold the TIMER/ALL OFF button for 3sec, backlight LED start flashing;
Step 4: Release the TIMER/ALL OFF button then click one of ZG or MEMERY A or MEMERY B
button before LED stop flashing. Then the Flashing stops immediately to indicate the
corresponding operating has completed successfully.
ALL of the Zero gravity position and the SF position and the Memory A position can be restored
to default sets by pressing and holding the TIMER/ALL OFF button for approximate six seconds
until the backlight LEDs finally stop flashing from first flashing.
Made by:
Checked by:
4/7
Confirmed by:
Date:
Operating manual
JLDP.03.045.000/JLDP.03.021/JLDP.03.053
2016-11-2
No:JLDP.03
Version:
1.1
Page 5 of 7
2.13. FLASHLIGHT
Click the FLASHLIGHT button, the Flashlight on the remote control will turn on if it is being off or
turn off if it is being on. If the Flashlight is turning on as the button pressed, it will keep on as long
as the button pressed. When the button is released, the Flashlight will still keep on for several
seconds then turn off with the backlight turning off together.
2.14. UNDERLIGHT
Click the UNDERLIGHT button, the Under‐light under the bed will turn on if it is being off or turn
off if it is being on. If the Under‐light is turning on as the button pressed, it will keep on for 5
minutes then turn off automatically if the button isn’t pressed again.
2.15. WAVE
Click the button the vibrating mode will change by one level, total 4 levels.When it has been level
3, it will return to level 0 if click the button.
2.16. Head Massage INTENSITY
Click the button the Head vibrating intensity will raise up one level, total 4 levels.If the previous is
level 3, now it will change to level 0 that means stopping.
2.17. FOOT Massage INTENSITY
Click the button the Foot vibrating intensity will raise up one level, total 4 levels.If the previous is
level 3, now it will change to level 0 that means stopping.
2.18. Massage Time
Press the button and released to stop all moves (including the actuators and vibrator) and
change circularly the vibrating time of the vibrator by one level once, total 3 levels。
The time means that vibrating keeps on for this period then automatically stops if no any button
related to vibrating is pressed again. The time and the LED indication are below:
Made by:
Checked by:
5/7
Confirmed by:
Date:
Operating manual
JLDP.03.045.000/JLDP.03.021/JLDP.03.053
2016-11-2
No:JLDP.03
Version:
1.1
Page 6 of 7
This LED flash a time, the vibrating time is 10minutes;
This LED flash a time, the vibrating time is 20minutes;
This LED flash a time, the vibrating time is 30minutes;
3、Wireless pairing operation
Step1: Push the DIP Switch on the remote control to a certain position(different from the
position on the other remote controls paired with the near other control boxes. ) and put in the
batteries.
Step2: Power on the control box.
Step3: Press and hold the pairing Tact Switch on the control box with the pairing LED turning on
until the pairing LED on the control box turns off ;then release the Tact Switch and the pairing Led
begins flashing that indicates the control box is pending to pair.
Step4: Press and hold simultaneously the Head‐Up button and the Foot‐Up button on the remote
control until backlight LED flashing. Release the two buttons and the backlight LED continue
flashing and search the control box pending to pair where the pairing Led is flashing, once both
the backlight on the remote control and the pairing Led on the control stop flashing, the pairing
operating is completed. To test if the pairing successfully, press the Head‐up or Head‐down or
Foot‐up or Foot‐down button,as so on, related to the actuators , if the click sound from the
relays in the control box can be heard that means it is successful. Otherwise, repeat the all above
steps.
It is strongly recommended that the near control boxes, for example, in a same house, should be
configured differently. Each control box must be paired with the different remote control where
the DIP‐Switch position is deferent. Doesn’t pair both control boxes with the same remote
control or the different one but in which the DIP‐switch position is same.
2.19. Bcakground LED
Click any button and release,the background LED goes out after 3 seconds。
2.20. Emergency button
Click the Emergency Lowering button on the control box once,the vibrating motor will be
stopped,Push the button ,the Head and Foot actuator will start up simultaneously and keep
running until arriving to their low limited switches.
Made by:
Checked by:
6/7
Confirmed by:
Date:
Operating manual
JLDP.03.045.000/JLDP.03.021/JLDP.03.053
2016-11-2
No:JLDP.03
Version:
1.1
Page 7 of 7
FCC:
Any Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
ISED RSS Warning:
This device complies with Innovation,Science and Economic Development Canada
licenceexemptRSS standard(s). Operation is subject to the following two conditions: (1) this
devicemay not cause interference, and (2) this device must accept any interference,
includinginterference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'ISED applicables aux appareils radioexempts
de licence.
L'exploitation est autorisée aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,même si le
brouillage est susceptible d'en compromettre le fonctionnement.
Made by:
Checked by:
7/7
Confirmed by:

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : baclsh67
Create Date                     : 2017:06:23 14:37:30+08:00
Modify Date                     : 2017:07:11 14:18:32-07:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Creator                         : baclsh67
Title                           : Microsoft Word - JLDP.03.045.000产品说明书&测试指导.docx
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2017:07:11 14:18:32-07:00
Producer                        : Acrobat Distiller 11.0 (Windows)
Document ID                     : uuid:a68626cb-5687-4703-a23f-57b46ecc013c
Instance ID                     : uuid:b21aa2e8-3d44-42a1-b9af-50d643357203
Page Count                      : 7
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PCU-JLDP03045

Navigation menu