OSANG Healthcare IGM-1003F Blood Glucose Test Meter User Manual
OSANG Healthcare Co., Ltd. Blood Glucose Test Meter
User Manual
Dear GluNEO Lite Smart Blood Glucose Monitoring System Owner, Thank you for choosing the GluNEO Lite Smart Blood Glucose Monitoring System. This manual contains everything you need to know about your new glucometer and how it works. Please take a moment to read the instructions carefully. We understand that self-testing of blood glucose level provides a way to control your diabetes and may give you peace of mind by testing regularly. GluNEO Lite Smart has been developed to provide you with a fast and accurate reading in a convenient and simple process. Our goal for the GluNEO Lite Smart Blood Glucose Monitoring System is to provide you with the best quality healthcare products coupled with superior customer service. Always consult with your healthcare professional, before making any changes to your diabetes management. The GluNEO Lite Smart Blood Glucose Monitoring System is for in-vitro diagnostic use only. Customer Service is available 24 hours a day, 7 days a week, and 365 days a year. Please call customer support center in your local area. Important Information The GluNEO Lite Smart Blood Glucose Monitoring System is intended for use outside the body (in-vitro diagnostic use only). It should be used only for testing blood glucose with fresh whole blood samples(Capillary and/or venous). It should not be used for the diagnosis of diabetes. Consult with your physician or diabetic healthcare professional about daily management of your diabetes and proper use of the glucometer. Please pay close attention when handling blood. Improper procedures may cause serious hazards to your health. The GluNEO Lite Smart Blood Glucose Monitoring System contains small parts, which could be a choking hazard for children if swallowed. Test Principle GluNEO Lite Smart blood glucose test strip is the bio-sensor which is composed of the FAD-dependent glucose dehydrogenase(enzyme). FAD-GDH(enzyme) quantitatively reacts with the glucose in the whole blood and the mediator. Glucose in the whole blood sample reacts with the reagent of the test strip and generates an electrical. The amount of current, which is related with glucose concentration, is measured by the current, for which the method is called amperometry. WARNING 1. All parts of the kit are considered bio-hazardous and can potentially transmit infectious diseases, even after you have taken cleaning and disinfection measures. 2. Always use a new, sterile lancet. Lancets are for single use only. 3. Avoid getting hand lotions, oil, dirt or debris in and/or on the lancets and reusable lancing device. 4. Please refer to page 33 for cleaning and disinfecting GluNEO Lite Smart Blood Glucose Monitoring System. 5. Do not change your medication based on the GluNEO Lite Smart meter test results without contacting your physician or healthcare professional first. 6. Do not assemble or disassemble the blood glucose test meter. 7. Keep out of direct sunlight. CAUTION 1. Please keep your monitoring system out of reach of children. 2. Make sure it does not come in contact with water and moisture. 3. Avoid getting dirt and moisture. 4. Close supervision is necessary when equipment is used by, on, or near children, handicapped persons or invalids. 5. Do not place the equipment in liquid, nor put it where it could fall into liquid. If the equipment becomes wet, unplug it before touching it. 6. Do not use accessories which are not supplied or recommended by the manufacturer. 7. Do not place anything on top of the equipment. NOTE: 1. Blood Glucose Monitoring System may also be called as Blood Glucose Test Meter, the Meter, Test Meter in this manual, for which they have equal meaning to each other. 2. Blood Glucose Test Strip may also be called as the Test Strip, Strip, for which they equal meaning to each other. Table of Contents 1. Learning the System Intended use of blood glucose test meter --------------------------------------------------- 6 GluNEO Lite Smart kit contents ---------------------------------------------------------------- 7 GluNEO Lite Smart meter ------------------------------------------------------------------------ 8 GluNEO Lite Smart meter Display ------------------------------------------------------------- 9 GluNEO Lite Smart test strip ---------------------------------------------------------------------10 2. Before Testing: Setting your meter ------------------------------------------------------------------------------12 Auto-coding function ----------------------------------------------------------------------------14 Performing a Glucose Control Solution Test------------------------------------------ 15-18 3. Performing your test: Testing Blood - preparation -------------------------------------------------------------- 19-20 Performing a blood test with your finger tip ------------------------------------------ 21-25 Test Strip ejector function ---------------------------------------------------------------------26 4. Reviewing Your Results: Reviewing your blood sugar ------------------------------------------------------------------27 Reviewing your averages ----------------------------------------------------------------------27 Reviewing your results with activated user ID --------------------------------------------28 Deleting test results -----------------------------------------------------------------------------28 5. Alternate Site Test: Lancing and sampling from an alternate site area --------------------------------- 29-31 Lancing device clear tip is used for alternate site testing-------------------------- 31-32 6. Caring for Your GluNEO Lite Smart System: Cleaning your meter and maintenance ---------------------------------------------------33 Storage of your GluNEO Lite Smart system ------------------------------------------ 34-35 Bluetooth function ---------------------------------------------------------------------------------- 36 7. Transferring Your Result Data ----------------------------------------------------------------37 8. Battery Installation -------------------------------------------------------------------------------38 9. Disposal ---------------------------------------------------------------------------------------------39 10. Trouble-shooting ---------------------------------------------------------------------------- 40-42 11. Inconsistent or Unexpected Test Results ------------------------------------------------43 12. Connection between mHealthGate and GluNEO Lite Smart ------------------------------44 13. Warranty -------------------------------------------------------------------------------------------48 14. Declaration of Conformity ---------------------------------------------------------------------49 14. Specifications ------------------------------------------------------------------------------------50 15. Symbol Reference-------------------------------------------------------------------------------51 Learning the System Intended use The GluNEO Lite Smart test meter is used with GluNEO Lite Smart test strip for the measurement of glucose in fresh whole blood samples(Capillary and/or venous). It should not be used for the diagnosis or screening of diabetes or for the testing of new born babies. GluNEO Lite Smart Blood Glucose Monitoring System is intended for use outside the body only(in-vitro diagnostic use). GluNEO Lite Smart Blood Glucose Monitoring System is for self-testing by people with diabetes and by healthcare professionals. Recorded results make it easier for your doctor to access your metabolic control. However, the self-testing should not take the place of overall diabetes management assessment from your doctor. CAUTION - Do not use system for any other purpose than blood glucose test. - Cholesterol concentrations > 510 mg/dL or triglyceride concentrations > 3,400 mg/dL may produce elevated reading. - Icodextrin does not interfere with GluNEO Lite Smart test strips. - Do not use during or soon after xylose absorption testing. Xylose in the blood will cause interference. - Before using any product, please read all instructions. - Consult with your physician or diabetic healthcare professional about daily manage- ment of your diabetes and proper use of the glucometer. If you have any questions about the GluNEO Lite Smart product, please contact your local representative. WARNING - Before using GluNEO Lite Smart system, read all instructions in this manual, and practice for accurate and safe test. You should have commentary recommendation from your diabetes care professional for the proper use of the meter and daily management of your diabetes. - If you think your blood glucose results are too low or too high, or if the results are doubtful, please contact your doctor. - If your blood glucose result is unusually low or high, or you do not feel the result is correct, repeat the test again with a new test strip. - If the results are still inconsistent, please consult with your physician before making any decision in controlling your diabetes. GluNEO Lite Smart Kit Contents Meter CarryingCase Lancing Device Lancets Battery 1. GluNEO Lite Smart Meter 2. GluNEO Lite Smart Test strip 3. Reusable Lancing Device 4. Lancets 5. Instructions for use 6. 7. 8. 9. Warranty Registration Card Carrying Case Patient Logbook 3V Coin (1EA) Battery (CR2032) Your GluNEO Lite Smart Blood Glucose Monitoring System has been sealed to protect the contents. If you find your seal has been broken, please return it to the place of purchase. GluNEO Lite Smart Meter Test Strip Port: Insert the GluNEO Lite Smart test strip Display Screen: Displays your test results, symbols, and messages. Power/Enter Button: Power the meter on/off, prompts memory data and acts as an “Enter” button during setup and after tests. Up/Down Arrow Buttons: Scroll up or down to adjust settings or retrieve memory. Test Strip Ejector: Releases and discards test strip. Serial Number Battery Cover CAUTION 1. Do not use GluNEO Lite Smart glucose test meter in a dry environment, especially If synthetic materials are present. Synthetic clothes, carpets, etc., may cause damaging static discharge in a dry environment. 2. Do not use GluNEO Lite Smart glucose test meter near cellular or cordless telephones, walkie-talkies, garage door openers, radio transmitters, or other electrical equipment that are sources of electromagnetic radiation, as these may interfere with the proper operation of the glucose test meter. GluNEO Lite Smart Meter Display Low Battery Warning Symbol Alarm Symbol Troubleshooting Symbol DATE Delete Results Average Test Result System Before Having a Meal After Having a Meal After Taking Medication After Sport Activity Control Solution Symbol Blood Drop Symbol for Test User ID Symbol Test Strip Code Symbol Test Result Unit Symbol Temperature / Date Time GluNEO Lite Smart Test Strip Test Strip Port Contact Bar Caution 1. Store the GluNEO Lite Smart test strip vials in a cool, dry place. Keep out of direct sunlight. Do not freeze. 2. Store test strips in their original vial only. Do not mix the test strips in new vials or in any other container. 3. Immediately replace the vial cap and close tightly after removing any test strips from the vial. 4. Make a note of the expiry date, which is six months from the date you first open a new vial of test strips. Throw GluNEO Lite Smart test strips and vial away after the expiry date. 5. Do not use the test strips after the expiration date printed on the package or vial, since it may cause inaccurate results. 6. GluNEO Lite Smart test strips should be single use only. DO NOT RE-USE. 7. Do not test at temperatures below 10 (50°F) or above 40 (104°F). 8. Do not test in the condition that humidity is below 10% or above 90%. 9. Do not bend, cut, or alter the test strip. 10. Avoid getting dirt, food, and water on the test strip with wet hands. 11. Avoid getting dirt, food, and water on the color-coding label (backside of test strip) 12. Refer to additional information in the GluNEO Lite Smart test strip package. Before Testing WARNING To reduce the chance of infection: 1. Lancing device and lancets should NOT be shared with others. 2. Always use a new lancet and a new blood glucose test strip. 3. Practice using the lancing device and become accustomed with its use. 4. Lancets and blood glucose test strips should be single use only. 5. Wash your hands in warm clean running water using soap before testing. 6. Avoid getting hand lotion, oils, dirt or debris on the lancets or on the lancing device. 7. Dry your hands completely before testing. Setting Your Meter The GluNEO Lite Smart Meter has a wide variety of functions to choose. From the setup mode you can turn activity/meal flags, set the date/time, designate three unique averages, and set up to five daily alarms. Power On Press for 3 seconds at least. Year After pressing and releasing either ▲ or ▼ buttons to set the year, push button. User Activity Option After pressing and releasing either ▲ or ▼ buttons to turn the User Activity Option on/off, push button. User ID Option After pressing and releasing either ▲ or ▼ buttons to turn the User ID option on/off, push button. Date / Time After pressing and releasing either ▲ or ▼ buttons to set the date and time, respectively push button. Test Unit After pressing and releasing either ▲ or ▼ buttons to set the test unit(mg/dL or mmol/L), push button. Temperature Unit After pressing and releasing either ▲ or ▼ buttons to set or and push button. Alarm time After pressing and releasing either ▲ or ▼ buttons to set the alarm hour and minute, push button. Number of days for average After pressing and releasing either ▲ or ▼ buttons to set the number of days for average calculation (3 different settings possible), push button. Alarm on/off After pressing and releasing either ▲ or ▼ buttons to turn the alarm on/off, push button. Alarm After programming the number of desired alarms (5 alarms possible),push button. CAUTION 1. VERY IMPORTANT: Set the right test unit. Your GluNEO Lite Smart Meter is pre-set to mg/dL as test unit. A wrong test unit will lead to wrong test result display. Please consult your healthcare professional if you’re not sure which test unit to use. Without setting the date properly, the average glucose level and the results in memory will not show proper values. It is recommended to set the glucose test meter before use and also when new batteries are installed. 2. You cannot test your blood glucose in the setting mode. 3. To turn the meter off during the setup, press for at least 3 seconds. Auto-coding Function 1. GluNEO Lite Smart has automatic code recognition function (e.g. CODE 125) 125 2. It recognizes the code number automatically. This is a very convenient function preventing the inconvenience of setting the code number on the glucose test meter every time. Check the code on the vial to see if the codes match each other CAUTION 1. Do not bend the glucose test strip to prevent the automatic code recognition failure. 2. If the code recognition label is damaged, code recognition may fail. Please check the code number on the LCD window together with the code number on the glucose test strip vial to see if code numbers match each other. Performing a Glucose Control Solution Test GluNEO Lite Smart control solution contains a known amount of glucose that reacts with GluNEO Lite Smart test strip. By comparing your control solution test results with the expected range printed on the test strip vial, you are able to check that the meter and test strips are working properly, and that you are performing the test correctly. It is very important that you perform routine checking to ensure accurate results. The Glucose control solution should be used - Before using a new box of test strips. - Whenever you suspect the blood glucose test meter or blood glucose test strip is not functioning properly. - If your blood glucose test results are not consistent with your symptoms, or if you think results are not accurate. - If you have dropped the blood glucose test meter. - For quality control in the point of care usage. - For teaching or learning the system. - When using the meter for blood glucose tests after any disinfection procedure. Firmly insert the test strip into the meter test port. Insert deeply in direction of arrow on test strip (arrow up). Please do not insert the glucose test strip upside down. 125 When you insert the glucose test strip into the glucose test meter, the power automatically adjusts the meter accordingly. Press and release either the ▲ or ▼ button, then, Control Solution bottle icon will appear. Then, press ). 1.Check the expiration date before performing a control solution test. Do not use if expired. Please note the expiration date marked on the control solution bottle. 2.Gently shake the control solution before use. 3.Discard the 1st drop of control solution. This will eliminate any residue. Place a drop of control solution liquid on a clean, dry surface (e.g. the lid of the test strip vial) 4.Dip the test strip into the control solution liquid. Results will appear in 5 seconds. Compare the result to the range printed on the test strip vial. Result should fall within that range. CAUTION 1. Control solution is for in-vitro diagnostic use only. This means that it is only used for testing outside the body. 2. Control solution is exclusively made for the GluNEO Lite Smart Blood Glucose Monitoring System. Do not use other brand control solutions made by other manufacturers. 3. Check the expiration date on the vial. Do not use, if expired. 4. Once opened, use it for the next three months only. Record the discard date on the control solution bottle. Discard after three months. 5. Do not swallow. This is NOT for human or animal consumption. 6. The control solution bottle icon contains letter ‘C,’ so as not to be confused with the medication bottle. This will allow you to understand differences between a control solution test and an actual blood test. For example only If you are using the normal control solution, according to this particular vial of strips, your meter should show a number between 80 and 120. Please note that the control values shown in the picture are not control ranges. NOTE - It is recommended that glucose control solution is stored at room temperature 20~25 (68~77 ) before testing. - Check the expiration date before performing a glucose control solution test. - Do not use beyond expiration date. Once opened, the control solution expires after 3 months. If your control solution test falls out of range, please follow the next steps before contacting customer support: - Check the expiration dates on all the products you are using. Be sure you are using GluNEO Lite Smart Control Solution. - Try another control solution test. If this test falls out of range, try another control solution test with a new unopened bottle of test strips. If you continue to get control soulution test results that fall outside the range, do not perform a glucose test. Please call customer support in your local area. Follow-up Action 1. Check your meter and test strips with the glucose control solution. 2. Perform your test again. CAUTION 1. If your glucose control solution falls out of range, do not perform a glucose test and please contact your local representative. 2. The glucose control solution’s measurement range has nothing to do with individual’s blood glucose level, as its own purpose is to check the status of test strip and meter. Discard the used control solution and test strips carefully, according to the local regulation. Performing Your Test Testing Blood - Preparation Lancing device is a convenient medical tool for collecting capillary blood samples for glucose monitoring or other tests which require one or two drops of blood. Being a more advanced lancing device, it provides ultimate safety and comfort for obtaining blood samples. An adjustable tip offers 5 different strength levels of skin penetration for individual user’s comfort, while a lancet ejector enables the safe disposal of the used lancet. As an added bonus, this also comes with a transparent tip for AST (Alternative Site Testing). CAUTION 1. Never use a lancet that has been used by someone else. Sharing lancet could lead to contamination. 2. If the lancing device is to be used by another person, the unit must be properly disinfected 3. Do not leave the lancet in the device after use. 4. A new lancet must only be placed into the lancing device directly before testing. 5. This device has many small parts and could be a choking hazard for children if swallowed. 6. In the case of hospital use, hospitals need to observe their own infection control protocols in order to avoid any contamination. 7. Always dispose of the used lancet in a biohazard garbage container. COMPONENTS Clear Tip Ejection System Depth Indicator/Adjustable Tip Lancet Holder Sliding Barrel Release Button USING THE CLEAR TIP (AST) 1. Place the lancing device and lancet on the skin in the chosen area, press and hold it continuously for a few seconds, then push the release button to take a blood sample. 2. Watch through the clear tip until a sufficient blood sample is taken. If there is not enough blood, gently massage the area until a sufficient sample is collected. STORAGE Products must be stored at room temperature protected from sunlight or moisture. CLEANING AND DISINFECTION -Clean and wipe the outer part of lancing device once a week at the minimum with a soft cloth dampened with mild soap and water. Wash the adjustable tip and clear tip, once a week with mild soap. -DO NOT immerse the lancing device in water or liquid. WARRANTY Lancing device has a 2-year warranty from the date of purchase. A malfunctioning device should be returned to the following address: put address: Performing a blood test with your fingertip Step 1 Firmly insert the test strip into the meter test port in the direction of arrow on test strip (arrow up). Please do not insert the glucose test strip upside down. 125 When you insert the glucose test strip into the glucose test meter, the power automatically turns on with the code and temperature. Make sure the code number matches on the test strip bottle (e.g. CODE 125). GluNEO Lite Smart automatically recognizes the test strip code number and adjusts the meter accordingly. A blinking test strip will appear at the top of the screen, which indicates that the meter is ready for testing. CAUTION 1. If you do not see the code displayed, pull the glucose test strip out of the port, and re-start the procedure from the beginning. 2. If you do not see the code displayed match the code printed in the vial, If the mismatch persists, please contact your local representative for assistance. 3. Avoid testing under direct sunlight, for a more accurate test result. 4. If you apply your blood sample before a blinking test strip on the screen, Er5 message will appear on LCD. Please refer to Page 40. Step 2 To obtain a suitable blood samples • Before obtaining a blood sample, wash your hands with warm, clean water and soap. Dry hands completely before testing. WARNING 1. All parts of the kit are considered bio hazardous and can potentially transmit infectious disease, even after you have conducted cleaning and disinfection measures. 2. Avoid getting hand lotion, oil, dirt or debris in or on the lancets (single use only) and the lancing device. 3. Wash your hands thoroughly with soap and clean water after handling the meter, lancing device and/or test strip. 1. Unscrew the lancing device tip. 2. Insert a sterile lancet into the lancing device. 3. Twist the protective cover off. Do not discard. 4. Put the lancing tip back and twist it tightly. 5. To adjust the depth setting: Use strength level 1-2 for soft skin, 3 for average skin, 4-5 for thick or calloused skin. 6. Pull the end of the lancet device back. 7. To prick your finger, push the center button. CAUTION 1. If the blood smears or runs, do not use such blood sample. Dry the area and gently squeeze another drop or puncture a new area of the finger. 2. Do not share reusable lancing device with anyone including other family members. Step 3 • Correct Completely Filled • Applying Blood Correct • Incorrect Poorly filled Incorrect GluNEO Lite Smart Test Meter only requires 0.5 ul sample volume. • Stick the edge of the test strip to the drop of blood. • The blood will automatically be ‘drawn’ into the test strip channel. • When your sample blood is enough, your meter will automatically count down. • Apply your blood to the glucose test strip and do not take off your finger until you get the beep sound. The test will automatically start. • Please respect recommended quantity of blood sample. Too much blood may cause malfunction of your meter by contaminating it. CAUTION 1. If the countdown does not start, do not add more blood to the glucose test strip. Discard the glucose test strip and restart testing. 2. If you do not conduct the test within 3 minutes, the glucose test meter will automatically power off to save battery life. In this case, test procedure should start again from the beginning. 3. You may get an inaccurate result if the blood sample is not completely filled. Step 4 • After the beeping sound, test will begin automatically, and your results will appear in 5 seconds. It should begin counting down from 5 to 1 second on the LCD display window. LCD window will display the result of your blood glucose level, temperature and time. • If you selected to use the User Activity option during set up, press and release ▲ or ▼ button to select the activity ( , , , ) that correlates with your result, then press and release the power button • If you do not select to use User Activity option during set up, press the power button • If you selected to use the User ID option during set up, press ▲ and ▼ button to select the correct User ID, then press the power button • Record the result value in your logbook. When glucose test strip is removed, glucose test meter turns off automatically. CAUTION 1. If the test result is out of the test range, “HI/Lo” message will be shown on the LCD window. 2. Safely discard used glucose test strips and lancets in the proper place, according to the local regulation. Test Strip Ejector Function Disposing of your test strip 1. Once the test is complete, push the test strip forward to remove the test strip from the meter 2. Used test strips may be considered bio hazardous waste in your area. Be sure to contact your local representative for proper disposal. Disposing of your lancet 1. Push the needle into the protective cover. 2. Pull the lancet out and discard accordingly. CAUTION 1. Pushing the ejector button too hard could cause a damage to the meter. 2. Do not give strong impact to blood glucose test meter. 3. Please follow the waste disposal regulations on the used lancets and strips imposed by your local authorities. Reviewing Your Results The GluNEO Lite Smart meter stores up to 365 test results in its built-in memory, along with the average sugar level for the number of days, which you had preset the glucose test meter to calculate. Reviewing Your blood sugar Press and release button. The most recent result appears first. Note the time and day of your blood sugar result. Press and release the ▼ button and your previous result will appear on the display Reviewing Your averages Press and release the ▲ button, and your average result will be displayed. Average Test Result Test Unit Test Result Amount Average Test Result Days Reviewing your results with activated user ID Press the button once and the User ID option will appear the LCD screen. Use ▲ or ▼ buttons to scroll and choose the correct user ID, then press the button. If you choose the User ID to check the stored results, only the results of the selected user ID are displayed. DATE Deleting Test Results Deleting individual test result To delete any individual test result in the memory, press ▲ or ▼ button for 3 seconds. Then displayed icon will start blinking. Deleting all the test results To delete all test results in the memory press ▲ and ▼ button for 3 seconds. Then displayed will start blinking. CAUTION Deleted test results cannot be recovered. Please be careful in deleting the test results. Alternative Site Test Upper Arm Forearm Dorsal Hand Ventral Palm Fingertips GluNEO Lite Smart blood glucose monitoring system gives you the ability to your sugar from different areas of your body. The figure shown above displays the areas where you can test using your GluNEO® Lite meter.You may test your blood sugar from your forearm, upper arm, palm (ventral palm or dorsal hand), or fingertips. IMPORTANT It is recommended that alternative site testing be used when sugars are stable: before meals and before bedtime. However, when sugars are changing, blood from the fingertip may show these changes sooner than blood from other body areas. LIMITATION 1. Alternative site testing results should never be used to calibrate continuous glucose monitoring systems. 2. Alternative sampling results should never be used in insulin dosing calculations. Lancing and sampling from an alternative site area Sampling from your upper arm, forearm, ventral palm, or dorsal hand allows you to use your fingertips less often. You may find that obtaining a blood sample from an alternative site is less painful than using a fingertip. Ventral palm/Dorsal hand Choose a fleshy area on the palm, below your thumb or pinky finger. Select a spot without any visible veins and away from any deep lines, which may cause your blood sample to smear. Forearm Upper arm Choose a fleshy area of the forearm or upper arm away from bone, visible veins and thick hairs of the arm. Sometimes there is less blood flow to these areas than to the fingertip. To help you get enough drops of blood, you may gently massage or apply a heating pad to the site to increase blood flow. IMPORTANT We recommend that you test on your fingertips if you are testing for hypoglycemia (low blood glucose) or if you are suffering from hypoglycemia unawareness. To ensure accurate results when lancing your arm (forearm or upper arm), or palm (ventral palm or dorsal hand), clean the test site with soap and water. Make sure there is no cream or lotion on the test site. Thoroughly dry your hands and test site. WARNING To reduce the chances of getting infection: never share a lancet or lancing device with anyone. The lancing device clear tip is used for alternate site testing Lance the test site with the lancing device 1. Remove the lancing tip by twisting off. 2. Insert lancet and replace with the clear tip. 3. To bring fresh blood to the surface of the test site, rub the test site vigorously for a few seconds until you feel it getting warm. Applying heat may be helpful. 4. Adjust clear tip to the highest setting. Hold the clear tip down against a fleshy area on the alternative site. Press the release button. Do not lift up. 5. Continue to hold the lancing device and gradually increase pressure for several seconds. 6. While holding the lancing device on your test site, look through the clear tip until a round drop of blood appears. 7. Lift the lancing device straight up; be careful not to smear the blood on your testing site. 8. Stick the edge of the test strip to the drop of blood. Blood will automatically be drawn up. REMEMBER 1. Consult with your healthcare professional before using alternate site testing. 2. Choose a different puncture site each time you test. Repeated punctures in the same spot may cause soreness and calluses. 3. If bruising occurs at an alternate site or you have difficulty getting a sample, consider sampling from a fingertip instead. You may want to review the choice of sites with your healthcare professional. 4. Do not share reusable lancing device with anyone including other family members. CAUTION Do not test on your forearm or palm when 1. You think you blood glucose is rapidly falling. For example within two hours of exercise, rapid-action insulin injection, or an insulin pump bolus. 2. Testing with a fingertip sample may identify hypoglycemia or an insulin reaction sooner than testing with a forearm or palm sample. Caring forYour GluNEO Lite Smart System Cleaning your meter and maintenance Blood glucose test meter : Your blood glucose test meter does not require special maintenance or cleaning. Avoid getting dirt, dust, blood, glucose control solution, or liquids on the blood glucose test meter, the test port, or data port. Your blood glucose test meter’s operation temperature is 10~40°C(50~104°F).It is recommended that you store the blood glucose test meter in the portable pouch after each use. A cloth dampened with water and mild detergent can be used to wipe down the outer part of the blood glucose test meter. Your GluNEO Lite Smart blood glucose test meter is a precision instrument. Please handle it with care. Lancing device : Clean the lancing device and tips with soap and tepid water. To disinfect the lancing device, prepare a disinfectant solution household bleach and water in 1(bleach) : 9(water) ratio. Dampen a cloth with this solution and wipe the lancing device thoroughly. Soak only the tip for at least 30 minutes in the disinfectant solution. Do not soak the lancing device in liquid. Rinse the lancing device and tip with water, and dry thoroughly. 1. For detailed instructions concerning GluNEO Lite Smart blood glucose test strips, refer to the blood glucose test strip package inserted and found in the blood glucose test strip box. 2. Please store the GluNEO Lite Smart blood glucose monitoring system in a cool and dry area, out of reach of children. Do not freeze. For a more accurate test result, avoid testing under direct sunlight. 3. Do not soak the blood glucose test meter or blood glucose test strips in water or liquid. 4. Do not subject the meter or blood glucose test strips to excessive heat. 5. Use your meter according to the instructions in the manual. 6. If you need to purchase the lancing device, lancets or blood glucose test strips, contact your local representative. 7. Discard the used lancets carefully, to prevent any infection. Storage of your GluNEO Lite Smart System To prevent the meter and test strips from getting dirt, dust or other contaminants, please wash and dry your hands thoroughly before use Meter Storage • Storage condition: 2~30 or 36~86 (Temperature) • Always store and transport the meter in its original storage case. • Avoid dropping and strong impact. • Avoid direct sunlight and humidity. Test Strip Storage • Storage condition: 2~30 or 36~86 (Temperature) • Store your test strips in their original vial only. Do not store the test strips in other containers. • Store test strip packages in a cool and dry place. Keep away from direct sunlight and heat. • Do not freeze. • After removing a test strip from the vial, immediately close it tightly. • Record the discard date (date vial opened, plus 6 months) on the test strip label. • Do not use if it is expired(2 years) after manufacturing. • Touch the test strip with clean and dry hands. • Do not use if 6 months have been passed, since the opening of the vial cap for test strips. Control Solution Storage • Storage condition: Store in a cool, dry place at between 8~30 or 46~86 (Temperature) • After use, close cap tightly. • Make sure the control solution bottle is tightly closed • Record the discard date (date vial opened, plus 3 months) on the control solution on the bottle. • Do not use if expiry date has passed. • It expires in 24 months after manufacturing date. • It expires in 3 months after opening the vial cap. CAUTION 1. Store the GluNEO Lite Smart test strip vials in a cool, dry place. Keep out of direct sunlight. Do not freeze. 2. Store test strips in their original vial only. Do not mix the test strips in new vials or in any other container. 3. Immediately replace the vial cap and close tightly after removing any test strips from the vial. 4. Make a note of the discard date, which is six months from the date you first open a new vial of test strips. Throw GluNEO Lite Smart test strips and vial away after the discard date. 5. Do not use the test strips after the expiration date printed on the package or vial, Testing with expired strips it may cause inaccurate results. 6. Do not test at temperatures below 10 (50°F) or above 40 (104°F). 7. Do not test with humidity below 10% or above 90%. 8. Do not bend, cut, or alter the test strip. 9. Avoid getting dirt, food, and water on the test strip with wet hands. 10. Avoid getting dirt, food, and water on the color-coding label (backside of test strip) Bluetooth Function GluNEO Lite Smart Meter stores glucose test result data and can transmit it to wireless device such as a Smart phone and Tablet PC via Bluetooth wireless technology. STEP 1 Launch the application on your mobile phone. If Bluetooth function or Bluetooth icon is already activated on the LCD’s first screen of your mobile phone, please move on to the next step. STEP 2 When you press UP button (Pair) at the same time as buzzer sound, the LCD window will display the “P” and the operating time count by one second units. The meter will begin to transfer Bluetooth signal to your mobile phone and to count up to 300. STEP 3 When the meter is paired with your mobile phone, the LCD window will display “C” which confirms the paired status. The meter can transfer the glucose test result data to external mobile device via Bluetooth wireless technology. STEP 4 Pressing the center/power button, the meter enters sleep mode and LCD display will then turn off. You can then navigate to the applications to view the other features. Transferring Your Result Data You can transfer test results from the GluNEO Lite Smart meter to a computer. You will need to download the software from the following web site (http://www.osanghc.com) and purchase the computer cable from your local representative. This is sold separately. [PC] [User] [cable] Battery Installation The low battery icon will appear in the upper left corner of the LCD display to alert you when the battery power is running low, which is an indication that a new battery is needed. Your GluNEO Lite Smart blood glucose test meter uses only one 3V lithium battery (CR2032), which is included. When replacing battery, only CR2032 or equivalent lithium battery should be used. Follow-up Action 1. Check your meter with the glucose control solution. 2. Perform your test again. 3. If you are experiencing symptoms that are not consistent with your blood glucose test results, call your healthcare professional. NOTE 1. Make sure your date and time are correct after changing your battery. 2. Please recycle or dispose of used batteries using your local battery collection systems and in compliance with your local environmental laws and regulations. 3. Caution risk of explosion if battery is replaced by an incorrect type. The following chart may help you identify certain problems, but may not solve all the problems that could occur. Contact your authorized representative or customer support center of OSANG Healthcare Co., Ltd., if the problem continues. OSANG Healthcare Co.,Ltd. Please insert a new glucose test strip and perform your test again. If “Sun”is blinking, avoid direct sunlight and re-test . Contact your local representative or customer support at OSANG Healthcare Co., Ltd., if the problem persists. Change the batterry and if the problem persists, contact your local representative or customer support at OSANG Healthcare Co., Ltd. ① Measure your blood glucose level by using GluNEO Lite Smart. ② Click mHealthGate app on your smartphone ③ Click “Connection device” button as below, and then select your connecting device. ④ Once the app is ready to receive your measuring value, following message is appeared. Turn off the power of the device by clicking power button, push Bluetooth button according to the message When Bluetooth mode is enabled, it starts counting numbers with beep sound ※ Refer to below image to find out the location of Bluetooth mode activation button When mode transfer is completed, touchbutton to start sending data. ⑤ If Bluetooth function is off status, ‘Bluetooth permission request’ is appeared as below. Push the to turn on Bluetooth to be connected with GluNEO Lite Smart device. ⑥ If the connection status between app and GluNEO Lite Smart is not set, the display of product number registration will be appeared. Register product serial number into your App. *You can check the location of product serial number at the backside of meter as below. ※ If product number is already registered, mHealthGate App starts connecting device without requesting the product number. [Display of product number registration] [In case that registered product number is different from the device product number] [Display of Data transmission] ⑦ Once the data is completely transferred, below display will be appeared. Select
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Language : ko-KR Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Creator : 김해리 사원님 Create Date : 2018:03:06 16:39:29+09:00 Creator Tool : Microsoft® Word 2010 Modify Date : 2018:03:08 18:24:03+09:00 Metadata Date : 2018:03:08 18:24:03+09:00 Producer : Microsoft® Word 2010 Document ID : uuid:8c811c6f-9805-4b89-a9ea-ddffe5211368 Instance ID : uuid:64c9affe-baa9-42e1-abf9-0e40bc606461 Page Count : 53 Author : 김해리 사원님EXIF Metadata provided by EXIF.tools