Olympus Maj 222 Users Manual C
MAJ-222 to the manual d056d3d2-9135-4864-9663-7d2e71b4cecb
2015-01-26
: Olympus Olympus-Maj-222-Users-Manual-344043 olympus-maj-222-users-manual-344043 olympus pdf
Open the PDF directly: View PDF .
Page Count: 1
Download | |
Open PDF In Browser | View PDF |
To use this chart as a wallchart, cut off the top of the chart as illustrated. To insert this chart into a binder, punch out the holes and fold the chart as illustrated. BRONCHOSCOPE DISINFECTION GUIDE EXERA™ BF-160 Series and EVIS™ BF-240 Series Bronchovideoscopes Refer to the companion BRONCHOSCOPE CLEANING GUIDE for detailed cleaning information WARNING: This guide is only a summary of the steps necessary to properly disinfect your bronchoscope. Be sure to follow the detailed steps outlined in the ENDOSCOPE REPROCESSING MANUAL that was included with your bronchoscope when purchased. HIGH-LEVEL DISINFECTION 2 1 3 4 Suction Cleaning Adapter Fill basin with disinfectant. Attach a suction cleaning adapter (MAJ-222) to the previously cleaned bronchoscope. Immerse completely in disinfectant solution. Attach a syringe to the adapter. Pull the plunger of the syringe to fill the instrument/suction channels and channel cleaning adapter with disinfectant solution. While immersed, detach the adapter from the bronchoscope. Use a clean, lint-free cloth to wipe away any bubbles clinging to external surfaces. RINSING Tube to suction 6 5 Soak all equipment according to the time and temperature recommended by the disinfectant manufacturer. Use a timer to measure the exact contact time. 7 8 To Suction Pump Suction Cleaning Adapter (MAJ-222) To Suction Pump Alcohol Connect the suction cleaning adapter and syringe. Inject air to remove disinfectant from the instrument/suction channels, then remove the bronchoscope from the disinfectant. Disconnect the suction cleaning adapter and immerse the bronchoscope and adapter in sterile water. Using a sterile, lint-free cloth, thoroughly rinse and wipe all surfaces. Connect suction cleaning adapter to bronchoscope and to a tube from a suction pump. Aspirate water through channels for 30 seconds. Remove from water and aspirate air through channels for 60 seconds. Immerse the bronchoscope's distal end in 70% alcohol and aspirate alcohol for 5 seconds. Remove the distal end from the alcohol and aspirate air for 20 seconds. TRANSPORTATION DRYING 9 10 Dry the bronchoscope and adapter with an alcohol-moistened cloth. Make sure that the equipment is completely dry prior to storage. IMPORTANT NOMENCLATURE Single-Use Suction Valve (MAJ-209) Light Guide Universal Cord Suction Cylinder Remote Switches Single-Use Biopsy Valve (MAJ-210) Instrument/Suction Channel Port Control Section UP/DOWN Angulation Control Lever Boot Hold all parts of the endoscope when carrying. Do not let the ends of the bronchoscope swing freely. Electrical Connector Venting Connector Water-Resistant Cap (MH-553) Insertion Tube Bending Section Distal Tip • Wear appropriate personal protective equipment during reprocessing. • Autoclave all autoclavable accessories. • Store the bronchoscope hanging vertically with all valves and caps removed. • Use a compatible disinfectant and test it for proper concentration as recommended by the manufacturer. • Do not use the carrying case to store "patient-ready" endoscopes. Any bronchoscope placed in the carrying case must be reprocessed prior to patient use. Clean the bronchoscope meticulously prior to disinfection. © 2004 Olympus America Inc. / Printed in USA 01/04 – PWC-100016 Turn the suction pump off. Hold the control section with the openings pointing down and disconnect the suction cleaning adapter.
Source Exif Data:
File Type : AI File Type Extension : ai MIME Type : application/vnd.adobe.illustrator PDF Version : 1.3 Linearized : No Modify Date : 2004:01:05 13:41:30-05:00 Create Date : 2004:01:05 13:41:27-04:00 Creator : Adobe Illustrator 10.0 Creator Version : 10 Container Version : 9 For : L. Edward Robinson, Olympus America Inc. Title : C:\WORK FOLDER\PROJECTS\COMPLETED\Wall Charts_12-2003\LOT 2\BF Video_Binder (11 x 16.5)\BF Disinfection Videoscope_BINDER (11 x 16.5).ai Bounding Box : -10 -1197 802 173 Page Count : 1 Creation Date : 2004:01:05 13:41:27-04:00 Mod Date : 2004:01:05 13:41:30-05:00 Producer : Adobe PDF library 5.00 Creator Tool : Adobe Illustrator 10.0 Metadata Date : 2004:01:05 13:41:30-05:00EXIF Metadata provided by EXIF.tools