QUICK START
GUIDE
ABOUT OMEGAWAVE
BEFORE YOU START
Thank you for purchasing the Omegawave system!
Please check the following:
The Omegawave assessment and guidance system is the only
solution available today that quickly provides a holistic view
of your body’s functional state. Empowered by physiological
feedback, you can optimize both your training and recovery.
1. Your ECG sensor matches your device. Check the model number
on the back side of the sensor:
•
OW-ECG1A is for Apple devices
Omegawave system allows you to:
•
OW-ECG1 is for Android devices
•
Optimize training
2. Your belt size is correct.
•
Manage recovery
•
Prevent injuries and avoid overtraining
•
Track progress
Our clinical grade ECG device takes a two minute recording of
the electrical activity of your heart and sends it to our cloud
server for physiological analysis. The results are then sent to
your Omegawave mobile application.
We help you understand your readiness to train, and the level
of recovery from different elements of stress. We then provide
you with guidelines for appropriate training for the day. After
multiple measurements, you will see how your aerobic condition is responding to your training. All this was previously only
available to pro athletes.
The measurement data gives you the confidence to train hard
when you are ready, and rest when necessary to reach your
goals faster.
The belt electrodes must be about 15 cm below the armpit
level.
3. You have charged the ECG sensor fully before the first use
using the supplied USB charger. Connect the USB charger to a
your computer to begin the Full charge takes up to 1 hour. The
sensor’s metal contacts must be aligned with the charger’s pins.
The red indicator turns off when the sensor is fully charged.
ACTIVATE THE OMEGAWAVE APP
CONDUCT THE MEASUREMENT
1.
1.
Make sure you have an active internet connection via mobile
data or WLAN
2.
Wet the electrode pads with water
3.
Adjust the belt strap
Download the application
Apple
Download the Omegawave application from the App Store. The
app is available for the newer device models, starting from
iPhone 3G or iPad 2. If you are using an iPad, you will find the
Omegawave application in the iPhone apps category.
Android
Download the Omegawave app from Google Play.
2.
Activate the application
Please note that for the app to work you need an active internet
connection via mobile data or WLAN.
Launch the Omegawave app and activate it using the username
and activation key received in your order confirmation email.
Your username is one of the following, depending on your initial
registration method:
•
If you have created a new Omegawave account to register,
your username is the email address used during the
registration.
•
If you have used Google+ to register, your username is the
Gmail address associated with your Google+ account.
•
If you have used Facebook to register, your username is the
email address associated with your Facebook account.
For accurate results, please ensure that the electrodes are about
15 cm below the armpit level and the belt is fitted tight around
your chest.
4.
Update your weight if necessary, then press “Start”. The measurement takes around two minutes. The app will signal twice
when the process is complete. Your results will be displayed
automatically.
Attach the sensor to the belt
For correct positioning, please ensure that the Omegawave logo
is facing up.
You can access your measurement results online for further
analysis at:
http://app.omegawave.com/
Your Personal Data will be stored in a secure environment and
treated confidentially. For more information about our privacy
policy please visit:
http://omegawave.com/privacy
Apple: Pair the sensor
Go to the Bluetooth settings on your phone and make sure that
Bluetooth is switched on. Locate the ECG sensor in the Bluetooth device list. Select the sensor (OW-ECG1A) from the device
list to complete the pairing process. This only needs to be done
when pairing the sensor for the first time.
5.
Conduct the measurement
Lie down and relax. Press “New Measurement” and
select the sensor from the list.
Apple
Select the ECG sensor (OW-ECG1A).
Android
Select the ECG sensor (OW-ECG1) from the device list and enter
the PIN code (0000) to complete the pairing process. This only
needs to be done during the first use.
6.
After the measurement
After the measurement please remove the sensor from the belt
to prevent battery drain. The sensor needs to be charged once
a week when used actively.
MEASUREMENT GUIDELINES
Common issues
1.
Put the sensor belt on, lay down and relax
1.
My Omegawave application cannot be activated
2.
Start the measurement
•
Check that your phone has an internet connection.
3.
Check the results after 2 minutes
•
Ensure that you are using the correct activation details:
•
When to measure?
•
Try to conduct measurements at the same time each day to
get the most accurate results. We suggest that you conduct
the measurement right before the training session or in the
morning, 30-60 minutes after waking up.
Recommendations for maintaining the accuracy of measurement results:
Your username and activation code are located in the
confirmation email received upon your registration.
2.
My phone does not connect to the ECG sensor
•
Make sure that your device’s operating system is up to date.
•
Make sure that the ECG sensor is charged.
•
Connect the charger to your computer and place the ECG sensor
on the charger to reset it. Make sure that the sensor’s metal
contacts are aligned with the charger’s pins.
•
If you are using same ECG sensor with multiple devices (e.g.
with your iPhone and iPad), please make sure that Bluetooth
is switched off on the second device when conducting the
measurement. This will prevent the sensor from connecting to
the wrong device.
•
If problems persist, please do the following:
•
Breathe normally, without holding your breath or breathing
too deep.
•
Try to find a quiet place for measurements. Avoid disturbances
such as talking or TV.
•
Lay down and relax. Rest your hands on your lap or at your
sides and wait for approximately two minutes to let your heart
rate stabilize before starting the measurement.
•
If you sneeze or cough during the measurement, please repeat
the measurement process.
•
Go to your device’s Bluetooth settings and turn Bluetooth
off.
•
Avoid consuming caffeinated drinks at least 30 minutes before
the measurement.
•
Rinse the belt’s electrodes with water, put on the belt and
attach the Omegawave ECG sensor.
•
Avoid conducting the measurement too soon after waking up.
Your body needs 30-60 minutes to properly awaken.
•
Turn Bluetooth back on.
•
Check that the ECG sensor is connected to your phone on
the Bluetooth device list. The sensor device name is OCECG1 for Android phones and OC-ECG1A for iPhones.
TAKING CARE OF THE ECG sensor
3.
My Omegawave application displays a white screen
•
Please check that your device has an active internet connection
via mobile data or WLAN.
•
Find information, ask questions and share your ideas on the
Omegawave community page:
The sensor needs to be charged once a week when used
actively.
•
Do not use electrode gel for wetting the belt’s electrode pads.
http://community.omegawave.com
•
Do not use the sensor nor the belt underwater.
•
Do not put the sensor into a washing machine or a dryer.
•
If you use perfume, deodorant or insect repellent, make sure it
does not come into contact with the belt’s electrode pads.
•
Do not leave the sensor or belt exposed to a heat source or
direct sunlight.
4.
I get different results on consecutive measurements
There is a specific time window that allows for the most accurate reflection of your heart rate variability (HRV). For accurate
and consistent results please make sure you let your body
enter a calm state by lying still for about two minutes prior to a
measurement. To do a repeated measurement, please stand up
for a minute to get your heart into its normal state before lying
back down and repeating the process.
REGULATORY INFORMATION
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
This device complies with Industry Canada licence-exempt
RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
Caution! Changes or modifications not expressly approved
by the party responsible for compliance could void the
user’s authority to operate the equipment.
www.omegawave.com
fb.com/omegawave
@omegawave on Twitter

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2013:08:08 14:14:19+03:00
Metadata Date                   : 2013:08:08 14:14:27+03:00
Modify Date                     : 2013:08:08 14:14:27+03:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:a9e93195-1172-4682-a74c-2de134cf9311
Original Document ID            : xmp.did:2B5C5409AE01E211AAAE9C6710E2B8BD
Document ID                     : xmp.id:CE2FF6921B00E311AEF8CBF9A45E3936
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:CD2FF6921B00E311AEF8CBF9A45E3936
Derived From Document ID        : xmp.did:273CB0060DC2E2119378B37A13A388F4
Derived From Original Document ID: xmp.did:2B5C5409AE01E211AAAE9C6710E2B8BD
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2013:08:08 14:14:19+03:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 7
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PTJ-0007

Navigation menu