Omron Okayama factory WE70AP FA Wireless LAN Unit User Manual

Omron Corporation Okayama factory FA Wireless LAN Unit Users Manual

User Manual

Download: Omron Okayama factory WE70AP FA Wireless LAN Unit User Manual
Mirror Download [FCC.gov]Omron Okayama factory WE70AP FA Wireless LAN Unit User Manual
Document ID775167
Application IDXH3GJCsG/MlLFYDxo3+RAg==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize20.61kB (257632 bits)
Date Submitted2007-04-02 00:00:00
Date Available2008-02-08 00:00:00
Creation Date2007-03-23 18:50:24
Producing SoftwareAdobe PDF library 4.800
Document Lastmod2007-04-02 17:12:32
Document TitleUsers Manual
Document CreatorAdobe Illustrator 9.0.2

WE70-AP/CL /-US/-EU/-CN
FA Wireless LAN Unit
This product uses electric wave for communication which may be broke up
temporarily due to its environment or usage.Safety of the system must be
maintained even in such a case.
Do not use this product for a real-time control application.
Instruction Sheet
ENG
WARNING
Thank you for your purchase of Omron's product.
Read and understand this instruction sheet before using this product for
safe and proper use.
This product must be handled by a qualified person who has sufficient
knowledge on electricity.
Keep this document close at hand for reference.
OMRON Corporation
DO NOT use this product close to any medical equipment such as a
pacemaker as it may affect operation of such medical equipment and may
result in heavy injuries.
CAUTION
In rare cases, light electric shock, fire, or failure of this product may occur.
Do not disassemble, modify, fix, or touch inside of this product.
Disassembly and modification are prohibited by the Radio Law in each countries.
©All Rights Reserved
T1
1112526-8A
Please read the following manual, as well for safe and appropriate use.
"WE70-AP/CL FA Wireless LAN Unit OPERATION MANUAL" (Cat.No.N153-E1(ENG))
Safety Precautions
● Warning Indication
WARNING
CAUTION
If you fail to use a product properly, it may result in
injuries, light or heavy, and may lead to death.
Also, a serious damage on property may be caused.
If you fail to use a product properly, it may result in
injuries or damage on property.
Do not use IEEE802.11 outdoors.
The Radio Law in Japan prohibits outdoor use of IEEE802.11a
(5.2GHz/5.3GHz band).
Within this product's frequency range, industrial, scientific, and medical
equipment as well as RFID premises radio station (license required) and
specified low power radio station (license not required) used in factory
manufacturing lines are operated.
(1) Before using this device, confirm that no RFID premises radio station or
specified low power radio station is operating close to it.
(2) If in case this product causes radio interference with an RFID premises
radio station, immediately change the product's frequency or stop radio
emission, and contact OMRON representative for actions to take to
prevent cross talk (e.g. installation of a partition)
(3) If any other problem occurred due to this product, such as radio
interference with an RFID specified low power radio station, contact
OMRON representative.
This product is given approvals of wireless standards from the following countries.
United States, Austria, Denmark, Finland, Germany, United Kingdom, Ireland, Italy,
Netherlands, Norway, Sweden, Switzerland,Spain, France, Belgium, Greece, Portugal,
Czech, Hungary, Poland, Slovenia, Slovakia
It cannot be used in other countries.
Suitability for Use
OMRON shall not be responsible for conformity with any standards, codes or
regulations that apply to the combination of the products in the customer's
application or use of the product.
Take all necessary steps to determine the suitability of the product for the
systems, machines, and equipment with which it will be used. Know and
observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
WARNING
DO NOT use this product without a protection circuit. Otherwise it may result
in heavy injuries or damage on life or property due to malfunction.
Dual or triple safety protection circuits, such as emergency stop, interlock, or
limit circuit, must be configured by external control circuit so that the system
should operate on safe side even if a failure of this product or an error due to
an external factor occurred.
Precautions for Safe Use
Observe the following precautions when using this product:
1) Dedicated packaging must be used for transportation of this
product.Take precautions to prevent excessive vibration or shock on the
product or falling of the product.
2) Storage of this product must be within the specified environment. Allow
the product to warm up to room temperature for at least 3 hours after it
has been stored at -10 degrees C or lower.
3) Use the product within the specified temperature and humidity ranges.
4) Do not use the product under the following environments:
• Locations subject to extreme temperature changes resulting in
condensation
• Locations subject to static electricity, excessive noise, or electric fields
• Locations where the product may come into contact with water, oil, or
chemicals
• Locations where corrosive gases or flammable gases are present
• Locations where large amounts of dust or dirt are present
• Locations subject to spatters, iron chips, or fillings
5) Do not use it outdoors (outside a control panel).
6) Use tape, cord, or other means to hold the product while adjusting the
installation position to prevent the product from damage due to failing.
7) Tighten the mounting screws to the specified torque of 4.4 to 5.3 in lb.
(0.5 to 0.6 N.m)
8) Provide sufficient space around the product for heat dissipation. Install
the products with a margin of 20mm or longer externally.
9) Do not reverse the power supply connection or connect the product to
an AC power supply.
10) Use the correct power supply voltage.
11) Use the solid wire, 26 to 17 AWG for power supply. The exposed length
of wire is 10 to 11mm.
12) Do not lay communications cables and antenna cables near other highvoltage cables or power lines.
13) Setup is required after the installation or replacement of this product. Set
up the product correctly according to the manual, and be sure to confirm
that communication is established before using it.
14) Do not apply excess vibrations or shock to this product. Do not drop this product.
15) Other wireless devices operating within the same frequency band may
interfere with this product or be adversely affected by this product.
Therefore, be sure to perform the test provided with the product (e.g.,
installation tests) before operating it.
16) Make sure that the antenna is not disconnected during operation.
17) Do not use this product near other devices that may malfunction due to
the electromagnetic waves emitted by this product.
18) Turn OFF the power supply before performing any wiring or replacing devices.
19) Do not touch the product with wet hands.
20) Dispose of the product as industrial waste.
We, the manufacturer (name of the manufacturer) hereby declare that this
equipment (type of the equipment), model WE70-AP-EU/WE70-CL-EU is
in compliance with the essential requirements and other relevant provisions of
Directive 1999/5/EC.
FCC WARNING
Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
NOTICE
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
STP cables must be used for connection to host computer and/or peripherals in order to
meet FCC emission limits.
In according with 47 CFR Part15.407(e) U-Nll devices operating in 5.15-5.25GHz
frequency bands are restricted to indoor operations only.
This transmitter must not be co-located or operated in conjunction with any other
antenna or transmitter.
This equipment complies with FCC radiation exposure limits set forth for uncontrolled
equipment and meets the FCC radio frequency (RF) Exposure Guidelines in
Supplement C to OET65. This equipment should be installed and operated with at least
20cm and more between the radiator and person's body (excluding extremities: hands,
wrists, feet and legs).
■ Specification
● Wireless LAN Block (5GHz, 54Mbps; Common in AP/CL)
■ Installation method
Mounting screws for this
wireless unit must be
tightened with torque of 4.4
to 5.3 in. lb. (0.5 to 0.6 N.m)
Magnet (Accessory)
● To mount Using Mounting Bracket
(1) Attach the mounting bracket on accessory magnets which are installed on wireless unit.
(Magnet is attached between mounting bracket and a wireless unit.)
Installation on a control panel requires screw hole drilling.
Flat-Head Screw
(Accessory)
Specification
Item
Standards
IEEE802.11a
Transmission Type
Orthogonal Frequency Division Multiplexing (OFDM), Simplex
Frequency Range
5150 to 5350MHz (8 channels), 5470 to 5725MHz (11 channels),
Flat-Head Screw (Accessory)
● Mounting Magnets
(2) Clamp screws in mounting holes.
Tapping Screw
(Accessory)
5725 to 5825MHz (5 channels)
Transmission speed
Maximum Transmission
Distance (Clear View)
Auto/54/48/36/24/18/12/9/6Mbps (theoretical)
Indoors: About 40m (Do not use it outdoors)
Mounting Bracket (Accessory)
● Wireless LAN Block (2.4GHz, 11Mbps/54Mbps; Common in AP/CL)
Specification
Item
Standards
IEEE802.11b/IEEE802.11g
Transmission Type
(Using 802.11b) Direct Sequence Spectrum Spread, Simplex
108 ±0.1
Mounting screws for this wireless unit
must be tightened with torque of 4.4 to
5.3 in. lb. (0.5 to 0.6 N.m)
(Using 802.11g) Orthogonal Frequency Division Multiplexing (OFDM), Simplex
Frequency Range
2400 to 2483.5MHz (13 channels or 11 channels)
Transmission speed
(Using 802.11b) Auto/11/5.5/2/1Mbps (theoretical)
(Using 802.11g) Auto/54/48/36/24/18/12/9/6Mbps (theoretical)
Maximum Transmission
Distance (Clear View)
Indoors: About 60m
● Common Spec for Wireless LAN Block (Common)
Specification
Item
* Do not install a product with a pencil-type antenna in a metal panel as it may
result in degradation of radio performance. To install this product in a panel,
use and install a magnetic-base antenna outside the panel.
WPA-PSK (with encryption type of AES <128-bit>
Insert a spring
/TKIP <128-bit>), WOC KEY
Group Communication
Comformance to ANY-connection refusal
Transmission Power
10mW/MHz or less
Antenna
Dual Band Diversity Antenna
Mounting Hole Process Drawing
(Unit: mm)
● To mount on a DIN rail
OCB AES <128-bit>, WEP (RC4) <64/128/152-bit>,
Security
4-M5
116 ±0.1
● Warning Indication
(3) Mount it on the main unit and clamp it
using screws (M3)
SMA Reverse Connector
● Wired LAN Block (Common)
Specification
Item
Standards
IEEE802.3 (10BASE-T), IEEE802.3u (100BASE-TX)
(Use STP LAN cables)
(1) Hold the part A and insert the tip
RJ-45 x 1
* Use straight cables for connection to PLC or PC.
● General Specification (Common)
Specification
Item
Main Unit Setup
Web Browser
Power
20.4 to 26.4 VDC (Screwless Terminal Block)
Current consumption
250mA max.
Ambient Operation Temperature
0 to +50 °C (With no condensation)
Dimensions
120(W) x 103(D) x 34.5(H)mm (excluding projection)
Weight
About 360g (Main Unit Only)
(2) Pull it to the right and lower it
while pressing the spring

Mounting screws for this wireless unit
must be tightened with torque of 4.4 to
5.3 in. lb. (0.5 to 0.6 N.m)
(1) Hitch a tab on the top to the DIN rail
● Other Functions
Item
Wireless LAN
Specification
DIN Rail
Supporting Communication Rate Enhancement
(2) Pull the bottom side forwards
Technology Atheros Super AG, Variable Transmission
Power (3 Levels: High/Mid/Low), Transmission Load
Distribution (Connection Terminal Limiting), 11g Protection,

(2) Unhitch a tab from the DIN rail
Client-to-Client Wireless Communication Inhibition,
Roaming, AP-to-AP bridging, MAC Address Registration
Security, SSID Setup Any Access Denial
Others
Supporting SYSLOG, Web Browser Setup, Administrator
ID Setup, Administrator IP Registration
WE70-AP
FA WIRELESS LAN ACCESS POINT
POWER MODE
LAN WIRELESS
DIN Rail
Insert a flat-head screw driver
under the lower tab and pull downward
(1) Pull the lower part

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2007:03:23 18:50:24+09:00
Creator                         : Adobe Illustrator 9.0.2
Modify Date                     : 2007:04:02 17:12:32+09:00
Creator Version                 : 9
Container Version               : 9
For                             : kitagawa tetsuya, iware
Bounding Box                    : -54 -56 1246 895
Page Count                      : 1
Has XFA                         : No
Creation Date                   : 2007:03:23 18:50:24+09:00
Producer                        : Adobe PDF library 4.800
Mod Date                        : 2007:04:02 17:12:32+09:00
Metadata Date                   : 2007:04:02 17:12:32+09:00
Title                           : E_WE70„»ŁiŁ[_0323F.pdf
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RXEWE70AP

Navigation menu