Omron Bp629 Users Manual
BP629 to the manual 0b91e296-ff5e-4917-8e04-2b6ae3da8c25
2015-01-24
: Omron Omron-Bp629-Users-Manual-332426 omron-bp629-users-manual-332426 omron pdf
Open the PDF directly: View PDF .
Page Count: 27
Download | |
Open PDF In Browser | View PDF |
INSTRUCTION MANUAL 3 series Automatic Wrist Blood Pressure Monitor ENGLISH ESPAÑOL Model BP629 TABLE OF CONTENTS Before using the Monitor Introduction ......................................................................................................... 3 Safety Information ................................................................................................ 4 Operating the Device .......................................................................... 4 Care and Maintenance ......................................................................... 5 Operating Instructions Before Taking a Measurement .............................................................................. 6 Know Your Unit ................................................................................................... 7 Unit Display ......................................................................................................... 8 Display Symbols ................................................................................................... 9 Irregular Heartbeat Symbol.................................................................. 9 Movement Error Symbol .................................................................... 9 Battery Installation ............................................................................................. 11 Setting the Date and Time .................................................................................. 13 Applying the Wrist Cuff ..................................................................................... 15 Applying the Cuff on the Left Wrist .................................................. 15 Applying the Cuff on the Right Wrist ................................................ 16 Taking a Measurement ....................................................................................... 17 Using the Memory Function ............................................................................... 19 Averaging Function ............................................................................ 19 To Display the Measurement Values ................................................. 19 To Delete All Values Stored in the Memory ..................................... 20 Care and Maintenance ............................................................................................... 21 Error Indicators ................................................................................................... 22 Troubleshooting Tips ........................................................................................... 23 FCC Statement .................................................................................................... 24 Limited Warranty ................................................................................................ 25 6SHFL¿FDWLRQV..................................................................................................... 26 2 INTRODUCTION Thank you for purchasing the OMRON® BP629 IntelliSense® Automatic Wrist Blood Pressure Monitor. Fill in for future reference. DATE PURCHASED:__________________ SERIAL NUMBER:____________________ s 3TAPLE YOUR PURCHASE RECEIPT HERE s 2EGISTER YOUR PRODUCT ON LINE AT WWWREGISTER OMRONCOM The monitor is compact and easy-to-use at home, at work, and during travel. Perfect for people who frequently monitor their own blood pressure. Your new digital blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood’s movement through your brachial artery and converts the movements into a digital reading. An oscillometric monitor does not need a stethoscope so the monitor is simple to use. Clinical research has proven a direct relationship between blood pressure in the wrist DQGEORRGSUHVVXUHLQWKHDUP&KDQJHVLQZULVWEORRGSUHVVXUHUHÀHFWFKDQJHVLQDUP blood pressure because the arteries in the wrist and the arm are close to each other. Frequently measuring the blood pressure in your wrist will provide your physician with an accurate indication of changes in your blood pressure. The BP629 comes with the following components: 0RQLWRU6WRUDJH&DVH³$$$´$ONDOLQH%DWWHULHV ,QVWUXFWLRQ0DQXDOSULQWHGLQ(QJOLVKDQG6SDQLVK4XLFN6WDUW*XLGH The BP629 IntelliSense® Automatic Wrist Blood Pressure Monitor is intended for home use. SAVE THESE INSTRUCTIONS 3 SAFETY INFORMATION To assure the correct use of the product, basic safety measures should always be followed including the warnings and cautions listed in this instruction manual. SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property. OPERATING THE DEVICE &RQWDFW\RXUSK\VLFLDQIRUVSHFL¿FLQIRUPDWLRQDERXW\RXUEORRGSUHVVXUH Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider. DO NOT adjust medication based on measurement results from this blood pressure monitor. Take medication as prescribed by your physician. Only a physician is TXDOL¿HGWRGLDJQRVHDQGWUHDW+LJK%ORRG3UHVVXUH The monitor is not intended to be a diagnostic device. ,IEDWWHU\ÀXLGVKRXOGJHWLQ\RXUH\HVLPPHGLDWHO\ULQVHZLWKSOHQW\RIFOHDQ water. Contact a physician immediately. If you have a condition that may compromise circulation, you may get an inaccurate reading with this device. Consult your physician before using this device. Read all of the information in the instruction manual and any other literature in the box before operating the unit. This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions. Operate the device only as intended. Do not use the device for any other purpose. Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution. 4 SAFETY INFORMATION Do not use a cellular phone near the device. It may result in an operational failure. Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit. 8VHRQO\9³$$$´DONDOLQHEDWWHULHVZLWKWKLVGHYLFH'RQRWXVHRWKHUW\SHVRI batteries. This may damage the unit. CARE AND MAINTENANCE 'RQRWVXEMHFWWKHPRQLWRUWRVWURQJVKRFNVVXFKDVGURSSLQJWKHXQLWRQWKHÀRRU Do not submerge the device or any of the components in water. Store the device and the components in a clean, safe location. &KDQJHVRUPRGL¿FDWLRQQRWDSSURYHGE\WKHPDQXIDFWXUHUZLOOYRLGWKHXVHU warranty. Do not disassemble or attempt to repair the unit or components. 5 BEFORE TAKING A MEASUREMENT To ensure a reliable reading follow these recommendations: 1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement. 2. Stress raises blood pressure. Avoid taking measurements during stressful times. 3. The cuff can be applied to your left or right wrist. 4. Measurements should be taken in a quiet place. 5. Position the unit at heart level throughout the measurement. 6. Remain still and do not talk during the measurement. 7. Wait 2-3 minutes between measurements. The wait time allows the arteries to return to the condition prior to taking the blood pressure measurement. You may need to increase the wait time depending on your individual physiological characteristics. 8. Keep a record of your blood pressure and pulse readings for your physician. A single measurement does not provide an accurate indication of your true blood pressure. You need to take and record several readings over a period of time. Try to measure your blood pressure at the same time each day for consistency. 6 KNOW YOUR UNIT Main Unit: Display Wrist cuff Memory (MEM) button START/STOP button Battery compartment Date/Time Setting ( Date/Time Setting ( ) button ) button Components: INSTRUCTION MANUAL 3 series Automatic Wrist Blood Pressure Monitor Model BP629 5329416-7A INTRODUCTION Thank you for purchasing the OMRON® BP629 IntelliSense® Automatic Wrist Blood Pressure Monitor . Fill in for future reference. DATE PURCHASED: __________________ SERIAL NUMBER: ____________________ 2 “AAA” Alkaline Batteries Instruction Manual 7 Quick Start Guide UNIT DISPLAY Systolic blood pressure Diastolic blood pressure Memory symbol Average value symbol Irregular heartbeat symbol Blood pressure level indicator Deflation symbol 8 Pulse display Movement error symbol Battery low symbol Date/Time display Heartbeat symbol (Flashes during measurement) DISPLAY SYMBOLS IRREGULAR HEARTBEAT SYMBOL ( ) When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values. $QLUUHJXODUKHDUWEHDWUK\WKPLVGH¿QHGDVD .ORMAL (EARTBEAT rhythm that varies by less than 25% from the Pulse average rhythm or 25% more than the average Blood rhythm detected while the monitor is measuring pressure the systolic and diastolic blood pressure. If the irregular heartbeat symbol ( ) )RREGULAR (EARTBEAT displays with your measurement results, Short Long we recommend you consult your Pulse physician. Follow the directions of your Blood doctor. pressure MOVEMENT ERROR SYMBOL ( ) The Movement Error Symbol ( ) is displayed if you move your body during the measurement. Please remove the wrist cuff, and wait 2-3 minutes. Reapply the wrist cuff and take another measurement. Internationally recognized guidelines for upper limit of normal home blood pressure readings are as follows: Home Guideline for Upper Limit of Normal BP Systolic Blood Pressure 135 mmHg Diastolic Blood Pressure 85 mmHg 9 DISPLAY SYMBOLS This is a general guideline because blood pressure depends on age and morbidity. A lower home blood pressure goal may be recommended for certain patients, including diabetic patients, pregnant women, and patients with renal failure. WARNING &RQWDFW\RXUSK\VLFLDQIRUVSHFL¿FLQIRUPDWLRQDERXW\RXUEORRGSUHVVXUH Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider. WARNING DO NOT adjust medication based on measurement results from this blood pressure monitor. Take medication as prescribed by your physician. Only DSK\VLFLDQLVTXDOL¿HGWRGLDJQRVHDQGWUHDW+LJK%ORRG3UHVVXUH WARNING The monitor is not intended to be a diagnostic device. 10 BATTERY INSTALLATION CAUTION 8VHRQO\9³$$$´DONDOLQHEDWWHULHVZLWKWKLVGHYLFH 1. Press the hook on the bottom of the battery cover and lift the cover off in the direction of the arrow. ,QVWDOO³$$$´VL]HEDWWHULHVVRWKHSRVLWLYHDQG (negative) polarities match the polarities of the battery compartment as indicated. 3. Set the date and time. 5HIHUWR³6HWWLQJWKH'DWHDQG7LPH´ 4. Replace the battery cover. NOTE: Make sure that the battery cover is securely in position. 11 BATTERY INSTALLATION BATTERY REPLACEMENT Low Battery Indicator When the Low Battery Indicator appears on the display, turn the monitor off and remove all the batteries. Replace with 2 new batteries at the same time. Long-life alkaline batteries are recommended. WARNING ,IEDWWHU\ÀXLGVKRXOGJHWLQ\RXUH\HVLPPHGLDWHO\ULQVHZLWK plenty of clean water. Contact a physician immediately. NOTES: 7XUQWKHXQLWRIIEHIRUHUHSODFLQJWKHEDWWHULHV,IWKHEDWWHULHVDUHUHPRYHG while the unit is still on, the date and time will be reset to that of the previous use. The measurement results are not deleted. :KHQWKHEDWWHULHVDUHUHSODFHG\RXPD\QHHGWRUHVHWWKHGDWHDQGWLPH,I ³´DSSHDUVRQWKHGLVSOD\UHIHUWR³6HWWLQJWKH'DWHDQG7LPH´ 7KHEDWWHULHVLQFOXGHGZLWKWKHGHYLFHPD\KDYHDVKRUWHUOLIH CAUTION Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution. 12 SETTING THE DATE AND TIME 6HWWKHPRQLWRUWRWKHFXUUHQWGDWHDQGWLPHEHIRUHWDNLQJDPHDVXUHPHQWIRUWKH¿UVW time. If the date and time has not been set, the measurement values are stored without any date or time information. 1. TO START THE SETTING Press the Date/Time Setting button ( ) to adjust the date and time. 7KH\HDUÀDVKHVRQWKHGLVSOD\ 2. SETTING THE YEAR Press the Date/Time Setting button ( ) to advance by increments of one year. Press the Date/Time Setting button ( ) to set the current year. 7KHPRQWKÀDVKHVRQWKHGLVSOD\ NOTES: 7KH\HDUFDQEHVHWEHWZHHQDQG When the display reaches 2040, it will return to 2010. 3UHVVDQGKROGWKH ) button to increase the date and time values faster. 13 SETTING THE DATE AND TIME 3. SETTING THE MONTH Press the Date/Time Setting button ( ) to advance by increments of one month. Press the Date/Time Setting button ( ) to set the current month. 7KHGD\ÀDVKHVRQWKHGLVSOD\ 4. SETTING THE DAY Press the Date/Time Setting button ( ) to advance by increments of one day. Press the Date/Time Setting button ( ) to set the current day. 7KHKRXUÀDVKHVRQWKHGLVSOD\ 5. SETTING THE HOUR The time is set using AM or PM. Press the Date/Time Setting button ( ) to advance by increments of one hour. Press the Date/Time Setting button ( ) to set the current hour. 7KHPLQXWHÀDVKHVRQWKHGLVSOD\ 6. SETTING THE MINUTE Press the Date/Time Setting button ( ) to advance by increments of one minute. Press the Date/Time Setting button ( ) to set the minute setting. 7. TO TURN THE MONITOR OFF Press the START/STOP button. 14 APPLYING THE WRIST CUFF CAUTION Read all of the information in the instruction manual and any other literature in the box before operating the unit. CAUTION This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions. APPLYING THE CUFF ON THE LEFT WRIST 1. Roll up sleeve. Make sure your sleeve is not rolled up too WLJKWO\RQ\RXUDUP7KLVPD\FRQVWULFWWKHÀRZRIEORRGLQ your arm. 2. Wrap the cuff directly against your skin. Do not apply over clothing. Place the cuff over your left wrist with your left thumb facing upward. 3. Position the cuff leaving a clearance of approximately 1/2 to 1 inch between the cuff and the bottom of your palm. 4. Hold the bottom part of the cuff and wrap it around the ZULVWVRLW¿WVFRPIRUWDEO\DQGVHFXUHO\DURXQG\RXUZULVW NOTE: Make sure the wrist cuff does not cover the protruding part of the wrist bone on the outside of the wrist. 15 APPLYING THE WRIST CUFF 5. Fold the remaining part of the wrist cuff back out of the way. APPLYING THE CUFF ON THE RIGHT WRIST When taking a measurement using the right wrist position the cuff as shown in the illustration. 16 TAKING A MEASUREMENT 6LWFRPIRUWDEO\LQDFKDLUZLWK\RXUIHHWÀDWRQWKHÀRRU 2. Hold your arm across your chest at heart level. +ROG\RXUHOERZ¿UPO\WRDYRLGERG\PRYHPHQW Sit still and do not talk or move during the measurement. 3. Press the START/STOP button. All symbols appear on the display. 17 TAKING A MEASUREMENT 7KHFXIIVWDUWVWRLQÀDWHDXWRPDWLFDOO\ $VWKHFXIILQÀDWHVWKHPRQLWRUDXWRPDWLFDOO\GHWHUPLQHV\RXULGHDOLQÀDWLRQOHYHO 7KLVPRQLWRUGHWHFWV\RXUEORRGSUHVVXUHDQGSXOVHUDWHGXULQJLQÀDWLRQ The Heartbeat Symbol ( ÀDVKHVDWHYHU\KHDUWEHDW Remain still and do not move until the entire measurement process is completed. NOTE:7RVWRSWKHLQÀDWLRQRUPHDVXUHPHQWSXVKWKH67$576723EXWWRQ7KH PRQLWRUZLOOVWRSLQÀDWLQJVWDUWGHÀDWLQJDQGZLOOWXUQRII 4. After the monitor has detected your blood pressure DQGSXOVHUDWHWKHFXIIDXWRPDWLFDOO\GHÀDWHV
Source Exif Data:File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Page Count : 27 Producer : Mac OS X 10.6.4 Quartz PDFContext Creator : Adobe InDesign CS3 (5.0) Create Date : 2010:09:23 14:13:18Z Modify Date : 2010:09:23 14:13:18ZEXIF Metadata provided by EXIF.tools