3G3RV-P10ST@-E

G7/F7/L7/E7 inverter PLC
The OMRON PLC technology embedded in
the OMRON Yaskawa inverter family
• OMRON PLC programmability in the
OMRON Yaskawa inverters.
• Flexibility and intelligence in the OMRON Yaskawa
inverter family.
• Wireless installation and seamless access to the
inverter parameters and analogue/digital inputs and
outputs.
• OMRON Compobus/S fieldbus inside. Thus, able to
control up to 256I/O's.
• Easy to integrate in the automation world:
DeviceNet type available.
• Standard OMRON tools can be used for programming and commissioning.
• Ideal for applications like:
• Pump sequencing, remote control, water
treatment,etc together with the HVAC inverter:
E7&E7 IP54.
• Lift as control sequence inside, using the lift
inverter: L7.
• Cranes, winding/rewinding, position control, others combined with the powerful flux vector control
inverter: F7Z.
• General purpouse using the high technology of
G7 3-Level vector control.

System configuration

RS-232C

CX-One

(CX-Drive)
(CX-Programmer)

HMI interface
RS-422

Other serial devices
DeviceNet

Varispeed + PLC

CompoBus/S communication path
Terminator

16 of 32 slaves max.

G7/F7/L7/E7 inverter PLC

365

Y203-EN2-02-Katalog.book Seite 366 Mittwoch, 24. Mai 2006 2:22 14

Type designation
PLC inverter
3G3RV-P10ST8-DRT-E
Inverter series
Number of I/O's

Options

1
2
3
5
6
7
8

Output
NPN
NPN
NPN
NPN
PNP
PNP
PNP
PNP

DRT
RTC
NO
NO
YES
YES
NO
NO
YES
YES

DeviceNet slave
No
Yes
RS422
NO
YES
NO
YES
NO
YES
NO
YES

Remarks

Standard

Specifications
Specifications by product
Item
PLC core
Inputs
Outputs
Peripheral port
RS-232C port
RS-422 port
Calendar/clock
Memory backup
Compobus/S master interface
Encoder interface
DeviceNet Slave interface

3G3RV-P10ST8-E
CPM2C-S
6 24 VDC inputs
4 sourcing/PNP transistor outputs
Yes
Yes
No
Yes
Flash memory and battery
Yes
Yes
No

3G3RV-P10ST8-DRT-E
CPM2C-S
6 24 VDC inputs
4 sourcing/PNP transistor outputs
Yes
Yes
Yes
Yes
Flash memory and battery
Yes
Yes
Yes

General specifications
Item
Rated power supply voltage
Communications power supply voltage
Power consumption Internal power
supply
Communications power supply
Vibration resistance
Ambient operating temperature
Ambient operating relative humidity
Ambient storage temperature
Atmosphere
Control method
I/O control method
Programming language
Instruction length
Instruction types
Basic
Special
Processing speed
Basic instructions
Special instructions
Program capacity
Maximum number of I/O points
Input bits
Output bits
CompoBus/S input bits
CompoBus/S output bits
Inverter interface

Inverter interface bits
Encoder interface bits
Work bits
Special bits (SR area)
Temporary bits (TR area)
Holding bits (HR area)
Auxiliary bits (AR area)

366

Specifications
3G3RV-P10ST8-E
3G3RV-P10ST8-DRT-E
24 VDC +10%/-15% (external power supply for I/O)
--11 to 25 VDC (supplied by communications connector)
2 W (supplied internally) (see note)
3 W (supplied internally) (see note)
--30 mA max.
10 to 20 Hz, 9.8 m/s2 max.
20 to 50 Hz, 2 m/s2 max
-10 to 45 °C
10% to 90% (no condensation)
-20 to 70 °C
Must be free from corrosive gas
Store program method
Cyclic scan method
Ladder chart method
1 step/1 instruction; 1 to 5 words/1 instruction
14 types (same as for programmable slaves)
105 types, 185 instructions (same as for programmable slaves)
0.64 µs (LD)
7.8 µs (MOV)
4,096 words
10
00000 to 00015 (6 physical inputs)
01000 to 01003 (4 physical outputs)
128 bits: IR 02000 to IR 02715 (bits not used for CompoBus/S input bits can be used for work bits.)
128 bits: IR 03000 to IR 03715 (bits not used for CompoBus/S output bits can be used for work bits.)
Direct interface with inverter through
• IR-memory
• DM-memory
• Transfer command
176 bits: IR 20000 to IR 21015
48 bits: IR 02900 to IR 02915 and IR 04800 to IR 04915
448 bits: IR 02800 to IR 02815, IR 03800 to IR 04715, and IR 21100 to IR 22715
448 bits: SR 22800 to SR 25507 (words SR 228 to SR 255)
8 bits (TR 0 to TR 7)
320 bits: HR 0000 to HR 1915 (words HR 00 to 19)
384 bits: AR 0000 AR 2315 (words AR 00 to AR 23)

3G3RV-P10ST@-E

Y203-EN2-02-Katalog.book Seite 367 Mittwoch, 24. Mai 2006 2:22 14

Item

Specifications

Link bits (LR area)
Timers/counters

CompoBus/S master functions

DeviceNet slave functions

DM area

Read/write
Read only
Inverter interface
Encoder interface
PLC setup

Interrupts

High-speed counters High-speed counter 1 input,
see note 5
Differential phase mode (5 kHz)
Pulse plus direction input mode
(20 kHz)
Up/down input mode (20 kHz)
Increment mode (20 kHz)
Interrupt inputs (counter mode)
2 inputs
Incrementing counter (2 kHz)
Decrementing counter (2 kHz)
Encoder interface

Pulse outputs

Synchronized pulse control

Pulse catch inputs

Analog volume
Input time constant
(ON response time = OFF response time)
Clock/Calendar function
Communication function

G7/F7/L7/E7 inverter PLC

3G3RV-P10ST8-E
3G3RV-P10ST8-DRT-E
256 bits: LR 0000 to LR 1515 (words LR 00 to LR 15)
256 timers/counters (TIM/CNT 000 to TIM/CNT)
1-ms timers: TMHH(--)
10-ms timers: TIMH(15)
100-ms timers: TIM
1-s/10-s timers: TIML(--)
Decrementing counters: CNT
Reversible counters: CNTR(12)
Remote I/O devices can be allocated up to 256 I/O points (128 inputs and 128 outputs) in input area IR 020 to
IR 027 and output area IR 030 to IR 037.
• The node numbers can be set to 0 to 7 (128-point mode) or 0 to 15 (256-point mode).
• The communications mode can be set to high-speed mode (max. length 100 m) or long-distance mode
(max. length 500 m).
Up to 64 words (32 input words and 32 output words) can be allocated to the DeviceNet master's I/O.
The master's I/O can be allocated to the following data areas:
IR 000 to IR 049
IR 200 to IR 227
DM 0000 to DM 2047
LR 00 to LR 15
HR 00 to HR 19
AR 00 to AR 23 (3G3RV-P10ST ' master; read-only)
TC 000 to TC 255
• Explicit message communications are supported. Any 3G3RV-P10ST data area can be accessed from the
DeviceNet master.
• The communications speed can be set to 500 kbps (total network length 100 m max.), 250 kbps (total network
length 250 m max.), or 125 kbps (total network length 500 m max.).
2,029 words (DM 0000 to DM 0999, DM 1019 to DM 2047)
DM 2000 to DM 2021: error log storage area
456 words (DM6144 to 6599)
19 words (DM 2022 to DM 2040)
14 words (DM 1986 to DM 1999)
56 words (DM 6599 to DM 6655)
Interrupt inputs
2 inputs
Response time: 50 µs
Interval timer interrupts
Scheduled interrupts
1 input
Set value: 0.5 to 319,968 ms
One-shot interrupt
Precision: 0.1 ms
No interrupt
Count-check interrupt
(An interrupt can be generated when the count equals the set value or the count lies within a preset range.)

No interrupt
Count-up interrupt

3 input modes:
Differential-phase (up/down)
Pulse plus direction
Up/down pulse
Maximum input frequency 50 kHz
Maximum counter range 4,294,967,295 (232-1)
Two capture registers, 3 selectable registration inputs
One comparison value
Counter reset through software or Z-phase
Interrupt function
• 2 outputs:
Single-phase pulse output without acceleration/deceleration (see note 6.)
10 Hz to 10 kHz
• 2 outputs:
Variable duty ratio pulse output (see note 6.)
0.1 to 999.9 Hz, duty ratio 0 to 100%
• 1 output:
Pulse output with trapezoidal acceleration/deceleration (see note 6.)
Pulse plus direction output, up/down pulse output, 10 Hz to 10 kHz
1 point, see notes 5 and 6
Input frequency range: 10 to 500 Hz, 20 Hz to 1 kHz, or 300 Hz to 20 kHz
Output frequency range: 10 Hz to 10 kHz
2 bits
Minimum pulse input: 50 µs max.
Used in common by input interrupts and input interrupt counter mode.
None
Determines the input time constant for all inputs. (settings: 1, 2, 3, 5, 10, 20, 40, or 80 ms)
Shows the current year, month, day of the week, day of the month, hour, minute, and second.
Port 1 = Peripheral and RS-422:
Host link, peripheral bus, no-protocol, programming console
Port 2 = RS-232C port:
Host link, no-protocol, 1:1 PLC link, 1:1 NT link

367

Y203-EN2-02-Katalog.book Seite 368 Mittwoch, 24. Mai 2006 2:22 14

Item

Specifications

Power-interruption hold function
Memory backup (see notes 1 and 2.)

Self-diagnostic function
Program check
Connected tools
CX-programmer
Programming console
SSS
CX-drive

3G3RV-P10ST8-E
3G3RV-P10ST8-DRT-E
Holds the contents of HR, AR, CNT, and DM areas.
Flash memory:
Program, read-only DM area, and PC setup
Memory backup: The read/write DM area, HR area, AR area, and counter values are backed up.
(The battery has a 5-year lifetime at 25 °C and it is replaceable.)
CPU errors, memory errors, communications errors, setting errors, battery errors
No END instruction, program errors (regularly checked during operation)
After version 2.1
C200H-PRO27, CQM1-PRO01
PC98 & PC/AT (SYSMAC support software, all versions)
Version 1 or higher

Note: 1. The DM area, HR area, AR area, and counter values are
backed up. If the backup battery or capacitor is discharged,
the contents of these areas will be lost and the data values will
revert to the defaults.
2. The contents of the program area, read-only DM area
(DM6144 to DM6599), and PLC setup (DM 6600 to DM 6655)
are stored in flash memory. The contents of these areas will
be read from flash memory the next time the power is turned
ON, even if the backup battery or capacitor is discharged.
When data has been changed in any of these areas, write the
new values to flash memory by switching the 3G3RV-P10ST
to MONITOR or RUN mode, or by turning the power OFF and
then ON again.

3. Changes made while in MONITOR mode using, for example,
online editing, are written to flash memory in real-time.
4. The above figure for power consumption includes the power
consumption of the programming console.
5. This input is shared by the high-speed counter and synchronized pulse control functions.
6. This output is shared by the pulse output and synchronized
pulse control functions.

I/O specifications
Input specifications
Item
Input voltage
Input impedance

Input current

ON voltage/current
OFF voltage/current
ON delay
OFF delay
Circuit configuration

Inputs
All
IN 00000 to IN 00001
IN 00002 to IN 00004
IN 00005
IN 00000 to IN 00001
IN 00002 to IN 00004
IN 00005
IN 00000 to IN 00001
IN 00002 to IN 00005
All
All
All
IN 00000 to IN 00001

Specification
24 VDC +10%/-15%
2.7 kΩ
3.9 kΩ
4.7 kΩ
8 mA typical
6 mA typical
5 mA typical
17 VDC min., 5 mA
14.4 VDC min., 3.5 mA
5.0 VDC max., 1.1 mA
1 to 80 ms max. Default: 10 ms (see note.)
1 to 80 ms max. Default: 10 ms (see note.)
IN
0.01
µF
1kΩ

COM

Internal circuits

2.7 kΩ

Input LED

IN 00002 to IN 00004

IN

Internal circuits

3.9 kΩ

820 Ω

COM
Input LED

IN 00005

IN

Internal circuits

4.7 kΩ

750 Ω

COM
Input LED

Note: The input time constant can be set to 1, 2, 3, 5, 10, 20, 40, or 80 ms in the PLC setup.

High-speed counter inputs
The following unit input bits can be used as high-speed counter inputs. The maximum count frequency is 5 kHz in differential phase mode and
20 kHz in the other modes.
Input

Function

IN 00000
IN 00001
IN 00002

Differential phase mode
Pulse plus direction input mode Up/down input mode
Increment mode
A-phase pulse input
Pulse input
Increment pulse input
Increment pulse input
B-phase pulse input
Direction input
Decrement pulse input
Normal input
Z-phase pulse input or hardware reset input (IN00002 can be used as a normal input when it is not used as a high-speed counter input.)

368

3G3RV-P10ST@-E

Y203-EN2-02-Katalog.book Seite 369 Mittwoch, 24. Mai 2006 2:22 14

The minimum pulse widths for inputs IN00000 (A-phase input) and IN00001 (B-phase input) are as follows:
Pulse plus direction input mode,
up/down inputmode, Increment mode

Differential phase mode
100 µs min.

50 µs min.

ON

90%
50%
10%

Phase A
ON

90%
50%
10%

OFF

OFF
ON

90%
50%
10%

Phase B
12.5 µs
min.

12.5 µs
min.

OFF
T1

T2

T3

T4

T1 T2 T3 T4: 12.5 µs min.

The minimum pulse width for input IN00002 (Z-phase input) is as follows:
50 µs min.
ON

90%
50%
10%

Phase Z
OFF
500 µs min.

Interrupt inputs
3G3RV-P10ST is equipped with inputs that can be used as interrupt inputs (interrupt input mode or counter mode) and quick-response inputs.
The minimum pulse width for these inputs is 50 µs.
Inputs IN 00003 and IN 00004 can be used as interrupt inputs.

Output specifications
Transistor outputs (sourcing/PNP)
Item
Maximum switching capacity
Minimum switching capacity
Maximum inrush current
Leakage current
Residual voltage
ON response time
OFF response time
Fuse
Circuit configuration

Specification
4.5 to 30 VDC, 0.2 A/output
0.5 mA
0.9 A for 10 ms
0.1 mA
1.5 V max.
20 µs max.
40 µs max. for 4.5 to 26.4 VDC, 10 to 100 mA
0.1 ms max for 4.5 to 30 VDC, 10 to 200 mA
One fuse per output (cannot be replaced by user)
Output LED
COM (+)
Internal
circuits

OUT

24 VDC

OUT

Note: When using OUT 01000 or OUT 01001 as a pulse output, connect a dummy resistor as required to bring the load current
between 0.01 and 0.1 A. If the load current is below 0.1 A, the
ON-to-OFF response time will be longer and high-speed pulses
(source-type transistor outputs) will not be output. If the load current is above 0.1 A, the transistor will generate more heat and
components may be damaged.

!Caution
Do not apply voltage in excess of the maximum switching capacity
to an output terminal. It may result in damage to the product or fire.

Encoder input specifications
Signal level

All

EIA RS-422-A standards

Input impedance

A- and B-phase

280 Ω

Z-phase

260 Ω

A- and B-phase

50 kHz max.

Z-phase

1 kHz max.

Response frequency
Circuit configuration

A- and B-phase

330 Ω

410 Ω

220 pF

Intrnal circuits

A
B

/A
/B
330 Ω

Z-phase

180 Ω

560 Ω

680 pF

Intrnal circuits

Z

/Z
180 Ω

G7/F7/L7/E7 inverter PLC

369

Y203-EN2-02-Katalog.book Seite 370 Mittwoch, 24. Mai 2006 2:22 14

Operation
CPU unit component descriptions

15. Low battery detection switch

14. Battery

17. DeviceNet indicators
18. CompoBus/S indicators
1. DIP switch

5. PLC status indicators
4. High-speed counter indicators
3. Output indicators
2. Input indicators

16. DeviceNet
node address

13. FE connection

8. DeviceNet port
6. Communications port
9. RS-422/485 port
11. CompoBus/S port
10. Terminating resistance switch
7. Communications switch

12. Digital I/O and
encoder interface

1. DIP switch

3. Output indicators (yellow)

• RS-232C and peripheral port settings

The output indicators are lit when the corresponding output terminal is
ON. The indicators are lit during I/O refreshing. The status of an output
indicator will also reflect the status of the corresponding output when
the output is being used as a pulse output.

ON
1 2 3 4

Pin 1
Effective port settings
The ports operate according to the settings in the
OFF
(default) PLC setup.
RS-232C port settings: DM 6645 to DM 6649
Peripheral port settings: DM 6650 to DM 6654
ON
The ports operate with the standard communications
settings.

4. High-speed counter indicators (yellow)
A
B

The indicators are lit when the corresponding input
terminal is ON.

Z

5. PLC status indicators
• Operating mode at startup
Pin 2 determines the operating mode at startup only if there isn't a
programming device connected to the peripheral port.

The following indicators show the operating status of the PLC.
PWR
RUN

Programming device
connected
None
Programming console
Other device

Startup mode with
Startup mode with
Pin 2 OFF (default)
Pin 2 ON
RUN mode
PROGRAM mode
Operating mode set on the programming console's
mode switch
PROGRAM mode

ERR/ALM
COMM1

Indicator
PWR
(green)
RUN
(green)

COMM2

Status
ON
OFF
ON
OFF

ERR/ALM
(red)

ON
Flashing

2. Input indicators (yellow)
IN0

OUT0

IN1

OUT1

IN2

OUT2

IN3

OUT3

The input indicators are lit when the corresponding
input terminal is ON. The status of an input indicator
will reflect the status of the input even when that input
is being used for a high-speed counter.

COMM1
(yellow)

OFF
Flashing
OFF

IN4
IN5

Note: 1. When interrupt inputs are used in interrupt input mode, the indicator may not light even when the interrupt condition is met
if the input is not ON long enough.
2. Input indicators will reflect the status of the corresponding inputs even when the PLC is stopped, but the corresponding input bits will not be refreshed.

370

COMM2
(yellow)

Flashing
OFF

Meaning
Power is being supplied to the unit
Power isn't being supplied to the unit
The PLC is operating in RUN or
MONITOR mode
The PLC is in PROGRAM mode or
a fatal error has occurred.
A fatal error has occurred.
(PLC operation stops.)
A non-fatal error has occurred.
(PLC operation continues.)
Indicates normal operation.
Data is being transferred via the
peripheral or RS-422/485 port.
Data isn't being transferred via
communications port.
Data is being transferred via the
RS-232C port
Data isn't being transferred via
communications port.

3G3RV-P10ST@-E

Y203-EN2-02-Katalog.book Seite 371 Mittwoch, 24. Mai 2006 2:22 14

6. Communications port

11. CompoBus/S port

Connects the PLC to a programming device (including programming
consoles), host computer, or standard external device. Use a proper
connecting cable (CPM2C-CN111, CS1W-CN114, CS1W-CN118, or
CS1W-CN226).

Terminal arrangement

Note: 1. A CQM1H-PRO01-E programming console can be connected directly to the PLC.
2. A C200H-PRO27-E programming console can be connected
directly to the PLC with a CS1W-CN224/CN624 connecting
cable.
3. Use a CPM2C-CN111 or CS1W-CN114 connecting cable to
connect to the communications port as a peripheral port. The
communications port can be used simultaneously as both a
peripheral port and RS-232C port by using the CPM2CCN111 connecting cable.
4. Use a CPM2C-CN111, CS1W-CN118 or CS1W-CN226 connecting cable to connect to the communications port as a RS232C port. The communications port can be used simultaneously as both a peripheral port and RS-232C port by using
the CPM2C-CN111 connecting cable
Note: The peripheral port and RS-422/485 port cannot be used simultaneously. When using the peripheral port disconnect any
devices connected to the RS-422/485 port.

BDH

4

2

BDL

3

1

Use special flat cable or VCTF cable for the transmission lines that connect the nodes in the CompoBus/S I/O Link. (Special flat cables and
VCTF cables cannot be combined in the same system.)
Name
Flat cable
VCTF cable

Model number
XB1T-W10
---

Specifications
4-core flat cable, 0.75 mm²
2-core VCTF, 0.75 x 20

12. Digital inputs and outputs and encoder interface

Connects the CPU unit to external input and output devices.
Sourcing outputs
Z-

BZ+

AB+

OUT3
A+

OUT1

OUT2

COM(+)

OUT0

IN5

COM

IN3
IN4

IN1(B)

IN2(Z)

IN0(A)

7. Communications switch

Switch to select port 1 type of connected device

13. Functional earth-wire

Position
Communication port 1
OFF (up) (default) Programming console
ON (down)
RS-422/485 communication

To be connected the earth connection inside the inverter.
14. Battery
15. Low battery detection switch

8. DeviceNet port (-DRT versions only)

This switch enables or disables the detection of a low-battery error.

CAN-L

Shield

CAN-H

V+

1

V-

ON

Terminal arrangement

Position
OFF (right)
(default)
ON (left)

Low-battery detection
Error detection enabled
Error detection disabled

9. RS-422/485 port

Used to connect to host computers, or standard external devices.
Terminal arrangement
Send
data
(output)
6

SDB+
5

Receive
data
(input)
RDB+

SDA-

16. DeviceNet node-number (-DRT versions only)

Please refer to the DeviceNet section
17. DeviceNet indicators (-DRT versions only)

Please refer to the DeviceNet section
18. CompoBus/S indicators

RDASD

Note: The maximum line length is 500 m.
The peripheral port and RS-422/485 port cannot be used simultaneously. When using the peripheral port disconnect any
devices connected to the RS-422/485 port.
When using RS-485 communication, connect RDA- to SDA- and
RDB+ to SDB+.

Indicator
SD
(yellow)

RD

Status
Flashing
OFF

ERC

RD
(yellow)

Flashing
OFF

ERC
(red)

Flashing
OFF

1

ON

10. Terminating resistance switch
Position
OFF (right)
(default)
ON (left)

Meaning
Data is being transmitted via
CompoBus/S
Data isn't being transmitted via
CompoBus/S
Data is being received via
CompoBus/S
Data isn't being received via
CompoBus/S
A CompoBus/S communications
error occurred.
A CompoBus/S communications
error hasn't occurred.

Termination
Disabled
Enabled

Set this switch to ON only for double-ended connection to a host link
network.

G7/F7/L7/E7 inverter PLC

371

Y203-EN2-02-Katalog.book Seite 372 Mittwoch, 24. Mai 2006 2:22 14

Dimensions

Application examples
G7 + PLC
Varispeed G7 is the OMRON Yaskawa solution using 3 level PWM control technology that provides lower surge voltage, low leakage current, low
bearing current, low acoustic noise and better EMC. By combining with PLC option board, it is the ideal solution for winding/unwiding applications,
handling / transfer / palletizer point-to-point positioning applications, press control applications, extruder control applications and pump
applications for examples ..

G7 + PLC in a water treatment application example
G7 + PLC
HMI interface

GSM modem
Compobus/S slaves

PH
sensor

Level
sensor

O2
sensor

Water

Note: For detailed information about the inverter, please see the Varispeed G7 series section.

372

3G3RV-P10ST@-E

Y203-EN2-02-Katalog.book Seite 373 Mittwoch, 24. Mai 2006 2:22 14

F7 + PLC
The F7 drive is a flux vector control inverter. It is intended to handle every conventional drive application found in a typical industrial manufacturing
plant from simple variable torque pumping to sophisticated networked material handling. By combining with PLC option board, is ideal solution
winding/unwiding applications, handling/ transfer/ palletizer point-to-point positioning applications, food processing, packaging, printing, and textile
machines for example .

F7 + PLC in a winding application example.

M

M

HMI interface

M

F7

F7

M

PG

F7 + PLC

F7

Encoder

Load cell

Note: For detailed information about the inverter, please see into the Varispeed F7 series section.

E7 + PLC
Varispeed E7 is the OMRON Yaskawa solution for energy saving applications The E7 is designed for variable torque applications such as fans
and centrifugal pumps. By combining with PLC option board, it is the ideal solution for water treatment, pump squencing, building automation and
fan applications for example...

E7 + PCL in HVAC application example
E7 + PLC

Water

Scada
building controller

Cooling tower

HMI interface
Analogue inputs

Air

Air
Digital
outputs
Air

Digital
inputs
Air
Temperature
sensors
Compobus/S
up to 16 / 32 slaves

Note: For detailed information about the inverter, please see into the Varispeed E7 series section.

G7/F7/L7/E7 inverter PLC

373

Y203-EN2-02-Katalog.book Seite 374 Mittwoch, 24. Mai 2006 2:22 14

L7 + PLC
The L7 is the ultimate drive for lift applications up to 3m/s. High starting torque, silent operation, lift-specific operator interface and operation with
both AC and PM motors are standard features of the L7 inverter. By combining with PLC option board, it is the ideal solution for controlling
distributed I/O’s, lift cabin HMI, GSM modem to send alarms for example..

L7 + PLC in lift application example
L7 + PLC
Compobus/S

Brake

Contactor

GSM modem

Safety limits

HMI interface

Lift cabin

Up to 256 I/O’s

Note: For detailed information about the inverter, please see into the Varispeed L7 series section.

374

3G3RV-P10ST@-E

Y203-EN2-02-Katalog.book Seite 375 Mittwoch, 24. Mai 2006 2:22 14

Ordering information
3G3IV-PCN329-E
Inverter to PC cable

CX-One

3G3IV-PCN126/326
Digital operator
extension cable

C

C

C

Varispeed

CompoBus/S
slaves

G7/F7/L7/E7
Inverter PLC

A

SRT2-ID
SRT2-OD
SRT2-ROC
SRT2-ROF
SRT2-ID_CL
SRT2-OD_CL
SRT2-AD
SRT2-DA

B

G7/F7/L7/E7 inverter PLC
Specifications
Inputs
6
6

Model
Ouptuts
4
4

RTC
Yes
Yes

Compobus/S master
Yes
Yes

RS422 port
Yes
NO

DeviceNet slave
No
Yes

3G3RV-P10ST8-E
3G3RV-P10ST8-DRT-E

A Varispeed
Specifications
The 3-Level control method inverter
Flux vector control inverter
The lift inverter
The pumps and fans inverter

Model
Varispeed G7
Varispeed F7
Varispeed L7
Varispeed E7

Note: For detailed information please refer to Varispeed G7/F7/L7/E7 series section.

B Cables
Specifications
Computer connecting cable
Programmable console cable

Model
CS1W-CN226
CS1W-CN224

B Computer software
Specifications
PLC programming software: CX-programmer
Inverter configurator software: CX-drive

G7/F7/L7/E7 inverter PLC

Model
CX-One

375

Y203-EN2-02-Katalog.book Seite 376 Mittwoch, 24. Mai 2006 2:22 14

C Compobus/S slaves
Product
Digital I/O terminals

Appearance

Specifications
4 NPN inputs (+ common)
4 PNP inputs (– common)
4 NPN outputs (– common)
4 PNP outputs (+ common)
8 NPN inputs (+ common)
8 PNP inputs (– common)
8 NPN outputs (– common)
8 PNP outputs (+ common)
16 NPN inputs (+ common)
16 PNP inputs (– common)
16 NPN outputs (– common)
16 PNP outputs (+ common)
8 Relay outputs
8 Power MOS FET relay outputs

Model
SRT2-ID04
SRT2-ID04-1
SRT2-OD04
SRT2-OD04-1
SRT2-ID08
SRT2-ID08-1
SRT2-OD08
SRT2-OD08-1
SRT2-ID16
SRT2-ID16-1
SRT2-OD16
SRT2-OD16-1
SRT2-ROC08
SRT2-ROF08

16 Relay outputs
16 Power MOS FET relay outputs

SRT2-ROC16
SRT2-ROF16

Analog input terminal

4 NPN inputs (+ common)
4 PNP inputs (– common)
4 NPN outputs (– common)
4 PNP outputs (+ common)
8 NPN inputs (+ common)
8 PNP inputs (– common)
8 NPN outputs (– common)
8 PNP outputs (+ common)
1 to 4 inputs (set with DIP switch)

SRT2-ID04CL
SRT2-ID04CL-1
SRT2-OD04CL
SRT2-OD04CL-1
SRT2-ID08CL
SRT2-ID08CL-1
SRT2-OD08CL
SRT2-OD08CL-1
SRT2-AD04

Analog output terminal

1 or 2 outputs (set with DIP switch)

SRT2-DA02

Relay output terminals

Waterproof terminals

Note: For detailed information about Compobus/S slaves, please refer to catalogue No. Y201-EN2-02 AS.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. I25E-EN-02

376

In the interest of product improvement, specifications are subject to change without notice.

3G3RV-P10ST@-E



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2006:05:31 09:46:28+02:00
Modify Date                     : 2006:05:31 10:04:18+03:00
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Mod Date                        : 2006:05:31 10:04:18+03:00
Creation Date                   : 2006:05:31 09:46:28+02:00
Author                          : smach
Metadata Date                   : 2006:05:31 10:04:18+03:00
Creator Tool                    : FrameMaker 6.0
Document ID                     : uuid:e0456a6c-9be0-46c2-a2a1-b88a85269ef6
Instance ID                     : uuid:c36f6060-eaae-46d4-a357-94e87914f697
Format                          : application/pdf
Title                           : Y203-EN2-02+Motion&Drives+Catalogue
Creator                         : smach
Has XFA                         : No
Page Count                      : 12
EXIF Metadata provided by EXIF.tools

Navigation menu