Omron E7 Users Manual Y203 EN2 02+Motion&Drives+Catalogue
G7, F7, L7, E7 I25E-EN-02+_7-InverterPLC+Datasheet
F7 to the manual 37daca88-f8d1-4d38-b990-77fd12d61557
2015-01-24
: Omron Omron-E7-Users-Manual-332542 omron-e7-users-manual-332542 omron pdf
Open the PDF directly: View PDF
.
Page Count: 12
| Download | |
| Open PDF In Browser | View PDF |
Y203-EN2-02-Katalog.book Seite 365 Mittwoch, 24. Mai 2006 2:22 14 3G3RV-P10ST@-E G7/F7/L7/E7 inverter PLC The OMRON PLC technology embedded in the OMRON Yaskawa inverter family • OMRON PLC programmability in the OMRON Yaskawa inverters. • Flexibility and intelligence in the OMRON Yaskawa inverter family. • Wireless installation and seamless access to the inverter parameters and analogue/digital inputs and outputs. • OMRON Compobus/S fieldbus inside. Thus, able to control up to 256I/O's. • Easy to integrate in the automation world: DeviceNet type available. • Standard OMRON tools can be used for programming and commissioning. • Ideal for applications like: • Pump sequencing, remote control, water treatment,etc together with the HVAC inverter: E7&E7 IP54. • Lift as control sequence inside, using the lift inverter: L7. • Cranes, winding/rewinding, position control, others combined with the powerful flux vector control inverter: F7Z. • General purpouse using the high technology of G7 3-Level vector control. System configuration RS-232C CX-One (CX-Drive) (CX-Programmer) HMI interface RS-422 Other serial devices DeviceNet Varispeed + PLC CompoBus/S communication path Terminator 16 of 32 slaves max. G7/F7/L7/E7 inverter PLC 365 Y203-EN2-02-Katalog.book Seite 366 Mittwoch, 24. Mai 2006 2:22 14 Type designation PLC inverter 3G3RV-P10ST8-DRT-E Inverter series Number of I/O's Options 1 2 3 5 6 7 8 Output NPN NPN NPN NPN PNP PNP PNP PNP DRT RTC NO NO YES YES NO NO YES YES DeviceNet slave No Yes RS422 NO YES NO YES NO YES NO YES Remarks Standard Specifications Specifications by product Item PLC core Inputs Outputs Peripheral port RS-232C port RS-422 port Calendar/clock Memory backup Compobus/S master interface Encoder interface DeviceNet Slave interface 3G3RV-P10ST8-E CPM2C-S 6 24 VDC inputs 4 sourcing/PNP transistor outputs Yes Yes No Yes Flash memory and battery Yes Yes No 3G3RV-P10ST8-DRT-E CPM2C-S 6 24 VDC inputs 4 sourcing/PNP transistor outputs Yes Yes Yes Yes Flash memory and battery Yes Yes Yes General specifications Item Rated power supply voltage Communications power supply voltage Power consumption Internal power supply Communications power supply Vibration resistance Ambient operating temperature Ambient operating relative humidity Ambient storage temperature Atmosphere Control method I/O control method Programming language Instruction length Instruction types Basic Special Processing speed Basic instructions Special instructions Program capacity Maximum number of I/O points Input bits Output bits CompoBus/S input bits CompoBus/S output bits Inverter interface Inverter interface bits Encoder interface bits Work bits Special bits (SR area) Temporary bits (TR area) Holding bits (HR area) Auxiliary bits (AR area) 366 Specifications 3G3RV-P10ST8-E 3G3RV-P10ST8-DRT-E 24 VDC +10%/-15% (external power supply for I/O) --11 to 25 VDC (supplied by communications connector) 2 W (supplied internally) (see note) 3 W (supplied internally) (see note) --30 mA max. 10 to 20 Hz, 9.8 m/s2 max. 20 to 50 Hz, 2 m/s2 max -10 to 45 °C 10% to 90% (no condensation) -20 to 70 °C Must be free from corrosive gas Store program method Cyclic scan method Ladder chart method 1 step/1 instruction; 1 to 5 words/1 instruction 14 types (same as for programmable slaves) 105 types, 185 instructions (same as for programmable slaves) 0.64 µs (LD) 7.8 µs (MOV) 4,096 words 10 00000 to 00015 (6 physical inputs) 01000 to 01003 (4 physical outputs) 128 bits: IR 02000 to IR 02715 (bits not used for CompoBus/S input bits can be used for work bits.) 128 bits: IR 03000 to IR 03715 (bits not used for CompoBus/S output bits can be used for work bits.) Direct interface with inverter through • IR-memory • DM-memory • Transfer command 176 bits: IR 20000 to IR 21015 48 bits: IR 02900 to IR 02915 and IR 04800 to IR 04915 448 bits: IR 02800 to IR 02815, IR 03800 to IR 04715, and IR 21100 to IR 22715 448 bits: SR 22800 to SR 25507 (words SR 228 to SR 255) 8 bits (TR 0 to TR 7) 320 bits: HR 0000 to HR 1915 (words HR 00 to 19) 384 bits: AR 0000 AR 2315 (words AR 00 to AR 23) 3G3RV-P10ST@-E Y203-EN2-02-Katalog.book Seite 367 Mittwoch, 24. Mai 2006 2:22 14 Item Specifications Link bits (LR area) Timers/counters CompoBus/S master functions DeviceNet slave functions DM area Read/write Read only Inverter interface Encoder interface PLC setup Interrupts High-speed counters High-speed counter 1 input, see note 5 Differential phase mode (5 kHz) Pulse plus direction input mode (20 kHz) Up/down input mode (20 kHz) Increment mode (20 kHz) Interrupt inputs (counter mode) 2 inputs Incrementing counter (2 kHz) Decrementing counter (2 kHz) Encoder interface Pulse outputs Synchronized pulse control Pulse catch inputs Analog volume Input time constant (ON response time = OFF response time) Clock/Calendar function Communication function G7/F7/L7/E7 inverter PLC 3G3RV-P10ST8-E 3G3RV-P10ST8-DRT-E 256 bits: LR 0000 to LR 1515 (words LR 00 to LR 15) 256 timers/counters (TIM/CNT 000 to TIM/CNT) 1-ms timers: TMHH(--) 10-ms timers: TIMH(15) 100-ms timers: TIM 1-s/10-s timers: TIML(--) Decrementing counters: CNT Reversible counters: CNTR(12) Remote I/O devices can be allocated up to 256 I/O points (128 inputs and 128 outputs) in input area IR 020 to IR 027 and output area IR 030 to IR 037. • The node numbers can be set to 0 to 7 (128-point mode) or 0 to 15 (256-point mode). • The communications mode can be set to high-speed mode (max. length 100 m) or long-distance mode (max. length 500 m). Up to 64 words (32 input words and 32 output words) can be allocated to the DeviceNet master's I/O. The master's I/O can be allocated to the following data areas: IR 000 to IR 049 IR 200 to IR 227 DM 0000 to DM 2047 LR 00 to LR 15 HR 00 to HR 19 AR 00 to AR 23 (3G3RV-P10ST ' master; read-only) TC 000 to TC 255 • Explicit message communications are supported. Any 3G3RV-P10ST data area can be accessed from the DeviceNet master. • The communications speed can be set to 500 kbps (total network length 100 m max.), 250 kbps (total network length 250 m max.), or 125 kbps (total network length 500 m max.). 2,029 words (DM 0000 to DM 0999, DM 1019 to DM 2047) DM 2000 to DM 2021: error log storage area 456 words (DM6144 to 6599) 19 words (DM 2022 to DM 2040) 14 words (DM 1986 to DM 1999) 56 words (DM 6599 to DM 6655) Interrupt inputs 2 inputs Response time: 50 µs Interval timer interrupts Scheduled interrupts 1 input Set value: 0.5 to 319,968 ms One-shot interrupt Precision: 0.1 ms No interrupt Count-check interrupt (An interrupt can be generated when the count equals the set value or the count lies within a preset range.) No interrupt Count-up interrupt 3 input modes: Differential-phase (up/down) Pulse plus direction Up/down pulse Maximum input frequency 50 kHz Maximum counter range 4,294,967,295 (232-1) Two capture registers, 3 selectable registration inputs One comparison value Counter reset through software or Z-phase Interrupt function • 2 outputs: Single-phase pulse output without acceleration/deceleration (see note 6.) 10 Hz to 10 kHz • 2 outputs: Variable duty ratio pulse output (see note 6.) 0.1 to 999.9 Hz, duty ratio 0 to 100% • 1 output: Pulse output with trapezoidal acceleration/deceleration (see note 6.) Pulse plus direction output, up/down pulse output, 10 Hz to 10 kHz 1 point, see notes 5 and 6 Input frequency range: 10 to 500 Hz, 20 Hz to 1 kHz, or 300 Hz to 20 kHz Output frequency range: 10 Hz to 10 kHz 2 bits Minimum pulse input: 50 µs max. Used in common by input interrupts and input interrupt counter mode. None Determines the input time constant for all inputs. (settings: 1, 2, 3, 5, 10, 20, 40, or 80 ms) Shows the current year, month, day of the week, day of the month, hour, minute, and second. Port 1 = Peripheral and RS-422: Host link, peripheral bus, no-protocol, programming console Port 2 = RS-232C port: Host link, no-protocol, 1:1 PLC link, 1:1 NT link 367 Y203-EN2-02-Katalog.book Seite 368 Mittwoch, 24. Mai 2006 2:22 14 Item Specifications Power-interruption hold function Memory backup (see notes 1 and 2.) Self-diagnostic function Program check Connected tools CX-programmer Programming console SSS CX-drive 3G3RV-P10ST8-E 3G3RV-P10ST8-DRT-E Holds the contents of HR, AR, CNT, and DM areas. Flash memory: Program, read-only DM area, and PC setup Memory backup: The read/write DM area, HR area, AR area, and counter values are backed up. (The battery has a 5-year lifetime at 25 °C and it is replaceable.) CPU errors, memory errors, communications errors, setting errors, battery errors No END instruction, program errors (regularly checked during operation) After version 2.1 C200H-PRO27, CQM1-PRO01 PC98 & PC/AT (SYSMAC support software, all versions) Version 1 or higher Note: 1. The DM area, HR area, AR area, and counter values are backed up. If the backup battery or capacitor is discharged, the contents of these areas will be lost and the data values will revert to the defaults. 2. The contents of the program area, read-only DM area (DM6144 to DM6599), and PLC setup (DM 6600 to DM 6655) are stored in flash memory. The contents of these areas will be read from flash memory the next time the power is turned ON, even if the backup battery or capacitor is discharged. When data has been changed in any of these areas, write the new values to flash memory by switching the 3G3RV-P10ST to MONITOR or RUN mode, or by turning the power OFF and then ON again. 3. Changes made while in MONITOR mode using, for example, online editing, are written to flash memory in real-time. 4. The above figure for power consumption includes the power consumption of the programming console. 5. This input is shared by the high-speed counter and synchronized pulse control functions. 6. This output is shared by the pulse output and synchronized pulse control functions. I/O specifications Input specifications Item Input voltage Input impedance Input current ON voltage/current OFF voltage/current ON delay OFF delay Circuit configuration Inputs All IN 00000 to IN 00001 IN 00002 to IN 00004 IN 00005 IN 00000 to IN 00001 IN 00002 to IN 00004 IN 00005 IN 00000 to IN 00001 IN 00002 to IN 00005 All All All IN 00000 to IN 00001 Specification 24 VDC +10%/-15% 2.7 kΩ 3.9 kΩ 4.7 kΩ 8 mA typical 6 mA typical 5 mA typical 17 VDC min., 5 mA 14.4 VDC min., 3.5 mA 5.0 VDC max., 1.1 mA 1 to 80 ms max. Default: 10 ms (see note.) 1 to 80 ms max. Default: 10 ms (see note.) IN 0.01 µF 1kΩ COM Internal circuits 2.7 kΩ Input LED IN 00002 to IN 00004 IN Internal circuits 3.9 kΩ 820 Ω COM Input LED IN 00005 IN Internal circuits 4.7 kΩ 750 Ω COM Input LED Note: The input time constant can be set to 1, 2, 3, 5, 10, 20, 40, or 80 ms in the PLC setup. High-speed counter inputs The following unit input bits can be used as high-speed counter inputs. The maximum count frequency is 5 kHz in differential phase mode and 20 kHz in the other modes. Input Function IN 00000 IN 00001 IN 00002 Differential phase mode Pulse plus direction input mode Up/down input mode Increment mode A-phase pulse input Pulse input Increment pulse input Increment pulse input B-phase pulse input Direction input Decrement pulse input Normal input Z-phase pulse input or hardware reset input (IN00002 can be used as a normal input when it is not used as a high-speed counter input.) 368 3G3RV-P10ST@-E Y203-EN2-02-Katalog.book Seite 369 Mittwoch, 24. Mai 2006 2:22 14 The minimum pulse widths for inputs IN00000 (A-phase input) and IN00001 (B-phase input) are as follows: Pulse plus direction input mode, up/down inputmode, Increment mode Differential phase mode 100 µs min. 50 µs min. ON 90% 50% 10% Phase A ON 90% 50% 10% OFF OFF ON 90% 50% 10% Phase B 12.5 µs min. 12.5 µs min. OFF T1 T2 T3 T4 T1 T2 T3 T4: 12.5 µs min. The minimum pulse width for input IN00002 (Z-phase input) is as follows: 50 µs min. ON 90% 50% 10% Phase Z OFF 500 µs min. Interrupt inputs 3G3RV-P10ST is equipped with inputs that can be used as interrupt inputs (interrupt input mode or counter mode) and quick-response inputs. The minimum pulse width for these inputs is 50 µs. Inputs IN 00003 and IN 00004 can be used as interrupt inputs. Output specifications Transistor outputs (sourcing/PNP) Item Maximum switching capacity Minimum switching capacity Maximum inrush current Leakage current Residual voltage ON response time OFF response time Fuse Circuit configuration Specification 4.5 to 30 VDC, 0.2 A/output 0.5 mA 0.9 A for 10 ms 0.1 mA 1.5 V max. 20 µs max. 40 µs max. for 4.5 to 26.4 VDC, 10 to 100 mA 0.1 ms max for 4.5 to 30 VDC, 10 to 200 mA One fuse per output (cannot be replaced by user) Output LED COM (+) Internal circuits OUT 24 VDC OUT Note: When using OUT 01000 or OUT 01001 as a pulse output, connect a dummy resistor as required to bring the load current between 0.01 and 0.1 A. If the load current is below 0.1 A, the ON-to-OFF response time will be longer and high-speed pulses (source-type transistor outputs) will not be output. If the load current is above 0.1 A, the transistor will generate more heat and components may be damaged. !Caution Do not apply voltage in excess of the maximum switching capacity to an output terminal. It may result in damage to the product or fire. Encoder input specifications Signal level All EIA RS-422-A standards Input impedance A- and B-phase 280 Ω Z-phase 260 Ω A- and B-phase 50 kHz max. Z-phase 1 kHz max. Response frequency Circuit configuration A- and B-phase 330 Ω 410 Ω 220 pF Intrnal circuits A B /A /B 330 Ω Z-phase 180 Ω 560 Ω 680 pF Intrnal circuits Z /Z 180 Ω G7/F7/L7/E7 inverter PLC 369 Y203-EN2-02-Katalog.book Seite 370 Mittwoch, 24. Mai 2006 2:22 14 Operation CPU unit component descriptions 15. Low battery detection switch 14. Battery 17. DeviceNet indicators 18. CompoBus/S indicators 1. DIP switch 5. PLC status indicators 4. High-speed counter indicators 3. Output indicators 2. Input indicators 16. DeviceNet node address 13. FE connection 8. DeviceNet port 6. Communications port 9. RS-422/485 port 11. CompoBus/S port 10. Terminating resistance switch 7. Communications switch 12. Digital I/O and encoder interface 1. DIP switch 3. Output indicators (yellow) • RS-232C and peripheral port settings The output indicators are lit when the corresponding output terminal is ON. The indicators are lit during I/O refreshing. The status of an output indicator will also reflect the status of the corresponding output when the output is being used as a pulse output. ON 1 2 3 4 Pin 1 Effective port settings The ports operate according to the settings in the OFF (default) PLC setup. RS-232C port settings: DM 6645 to DM 6649 Peripheral port settings: DM 6650 to DM 6654 ON The ports operate with the standard communications settings. 4. High-speed counter indicators (yellow) A B The indicators are lit when the corresponding input terminal is ON. Z 5. PLC status indicators • Operating mode at startup Pin 2 determines the operating mode at startup only if there isn't a programming device connected to the peripheral port. The following indicators show the operating status of the PLC. PWR RUN Programming device connected None Programming console Other device Startup mode with Startup mode with Pin 2 OFF (default) Pin 2 ON RUN mode PROGRAM mode Operating mode set on the programming console's mode switch PROGRAM mode ERR/ALM COMM1 Indicator PWR (green) RUN (green) COMM2 Status ON OFF ON OFF ERR/ALM (red) ON Flashing 2. Input indicators (yellow) IN0 OUT0 IN1 OUT1 IN2 OUT2 IN3 OUT3 The input indicators are lit when the corresponding input terminal is ON. The status of an input indicator will reflect the status of the input even when that input is being used for a high-speed counter. COMM1 (yellow) OFF Flashing OFF IN4 IN5 Note: 1. When interrupt inputs are used in interrupt input mode, the indicator may not light even when the interrupt condition is met if the input is not ON long enough. 2. Input indicators will reflect the status of the corresponding inputs even when the PLC is stopped, but the corresponding input bits will not be refreshed. 370 COMM2 (yellow) Flashing OFF Meaning Power is being supplied to the unit Power isn't being supplied to the unit The PLC is operating in RUN or MONITOR mode The PLC is in PROGRAM mode or a fatal error has occurred. A fatal error has occurred. (PLC operation stops.) A non-fatal error has occurred. (PLC operation continues.) Indicates normal operation. Data is being transferred via the peripheral or RS-422/485 port. Data isn't being transferred via communications port. Data is being transferred via the RS-232C port Data isn't being transferred via communications port. 3G3RV-P10ST@-E Y203-EN2-02-Katalog.book Seite 371 Mittwoch, 24. Mai 2006 2:22 14 6. Communications port 11. CompoBus/S port Connects the PLC to a programming device (including programming consoles), host computer, or standard external device. Use a proper connecting cable (CPM2C-CN111, CS1W-CN114, CS1W-CN118, or CS1W-CN226). Terminal arrangement Note: 1. A CQM1H-PRO01-E programming console can be connected directly to the PLC. 2. A C200H-PRO27-E programming console can be connected directly to the PLC with a CS1W-CN224/CN624 connecting cable. 3. Use a CPM2C-CN111 or CS1W-CN114 connecting cable to connect to the communications port as a peripheral port. The communications port can be used simultaneously as both a peripheral port and RS-232C port by using the CPM2CCN111 connecting cable. 4. Use a CPM2C-CN111, CS1W-CN118 or CS1W-CN226 connecting cable to connect to the communications port as a RS232C port. The communications port can be used simultaneously as both a peripheral port and RS-232C port by using the CPM2C-CN111 connecting cable Note: The peripheral port and RS-422/485 port cannot be used simultaneously. When using the peripheral port disconnect any devices connected to the RS-422/485 port. BDH 4 2 BDL 3 1 Use special flat cable or VCTF cable for the transmission lines that connect the nodes in the CompoBus/S I/O Link. (Special flat cables and VCTF cables cannot be combined in the same system.) Name Flat cable VCTF cable Model number XB1T-W10 --- Specifications 4-core flat cable, 0.75 mm² 2-core VCTF, 0.75 x 20 12. Digital inputs and outputs and encoder interface Connects the CPU unit to external input and output devices. Sourcing outputs Z- BZ+ AB+ OUT3 A+ OUT1 OUT2 COM(+) OUT0 IN5 COM IN3 IN4 IN1(B) IN2(Z) IN0(A) 7. Communications switch Switch to select port 1 type of connected device 13. Functional earth-wire Position Communication port 1 OFF (up) (default) Programming console ON (down) RS-422/485 communication To be connected the earth connection inside the inverter. 14. Battery 15. Low battery detection switch 8. DeviceNet port (-DRT versions only) This switch enables or disables the detection of a low-battery error. CAN-L Shield CAN-H V+ 1 V- ON Terminal arrangement Position OFF (right) (default) ON (left) Low-battery detection Error detection enabled Error detection disabled 9. RS-422/485 port Used to connect to host computers, or standard external devices. Terminal arrangement Send data (output) 6 SDB+ 5 Receive data (input) RDB+ SDA- 16. DeviceNet node-number (-DRT versions only) Please refer to the DeviceNet section 17. DeviceNet indicators (-DRT versions only) Please refer to the DeviceNet section 18. CompoBus/S indicators RDASD Note: The maximum line length is 500 m. The peripheral port and RS-422/485 port cannot be used simultaneously. When using the peripheral port disconnect any devices connected to the RS-422/485 port. When using RS-485 communication, connect RDA- to SDA- and RDB+ to SDB+. Indicator SD (yellow) RD Status Flashing OFF ERC RD (yellow) Flashing OFF ERC (red) Flashing OFF 1 ON 10. Terminating resistance switch Position OFF (right) (default) ON (left) Meaning Data is being transmitted via CompoBus/S Data isn't being transmitted via CompoBus/S Data is being received via CompoBus/S Data isn't being received via CompoBus/S A CompoBus/S communications error occurred. A CompoBus/S communications error hasn't occurred. Termination Disabled Enabled Set this switch to ON only for double-ended connection to a host link network. G7/F7/L7/E7 inverter PLC 371 Y203-EN2-02-Katalog.book Seite 372 Mittwoch, 24. Mai 2006 2:22 14 Dimensions Application examples G7 + PLC Varispeed G7 is the OMRON Yaskawa solution using 3 level PWM control technology that provides lower surge voltage, low leakage current, low bearing current, low acoustic noise and better EMC. By combining with PLC option board, it is the ideal solution for winding/unwiding applications, handling / transfer / palletizer point-to-point positioning applications, press control applications, extruder control applications and pump applications for examples .. G7 + PLC in a water treatment application example G7 + PLC HMI interface GSM modem Compobus/S slaves PH sensor Level sensor O2 sensor Water Note: For detailed information about the inverter, please see the Varispeed G7 series section. 372 3G3RV-P10ST@-E Y203-EN2-02-Katalog.book Seite 373 Mittwoch, 24. Mai 2006 2:22 14 F7 + PLC The F7 drive is a flux vector control inverter. It is intended to handle every conventional drive application found in a typical industrial manufacturing plant from simple variable torque pumping to sophisticated networked material handling. By combining with PLC option board, is ideal solution winding/unwiding applications, handling/ transfer/ palletizer point-to-point positioning applications, food processing, packaging, printing, and textile machines for example . F7 + PLC in a winding application example. M M HMI interface M F7 F7 M PG F7 + PLC F7 Encoder Load cell Note: For detailed information about the inverter, please see into the Varispeed F7 series section. E7 + PLC Varispeed E7 is the OMRON Yaskawa solution for energy saving applications The E7 is designed for variable torque applications such as fans and centrifugal pumps. By combining with PLC option board, it is the ideal solution for water treatment, pump squencing, building automation and fan applications for example... E7 + PCL in HVAC application example E7 + PLC Water Scada building controller Cooling tower HMI interface Analogue inputs Air Air Digital outputs Air Digital inputs Air Temperature sensors Compobus/S up to 16 / 32 slaves Note: For detailed information about the inverter, please see into the Varispeed E7 series section. G7/F7/L7/E7 inverter PLC 373 Y203-EN2-02-Katalog.book Seite 374 Mittwoch, 24. Mai 2006 2:22 14 L7 + PLC The L7 is the ultimate drive for lift applications up to 3m/s. High starting torque, silent operation, lift-specific operator interface and operation with both AC and PM motors are standard features of the L7 inverter. By combining with PLC option board, it is the ideal solution for controlling distributed I/O’s, lift cabin HMI, GSM modem to send alarms for example.. L7 + PLC in lift application example L7 + PLC Compobus/S Brake Contactor GSM modem Safety limits HMI interface Lift cabin Up to 256 I/O’s Note: For detailed information about the inverter, please see into the Varispeed L7 series section. 374 3G3RV-P10ST@-E Y203-EN2-02-Katalog.book Seite 375 Mittwoch, 24. Mai 2006 2:22 14 Ordering information 3G3IV-PCN329-E Inverter to PC cable CX-One 3G3IV-PCN126/326 Digital operator extension cable C C C Varispeed CompoBus/S slaves G7/F7/L7/E7 Inverter PLC A SRT2-ID SRT2-OD SRT2-ROC SRT2-ROF SRT2-ID_CL SRT2-OD_CL SRT2-AD SRT2-DA B G7/F7/L7/E7 inverter PLC Specifications Inputs 6 6 Model Ouptuts 4 4 RTC Yes Yes Compobus/S master Yes Yes RS422 port Yes NO DeviceNet slave No Yes 3G3RV-P10ST8-E 3G3RV-P10ST8-DRT-E A Varispeed Specifications The 3-Level control method inverter Flux vector control inverter The lift inverter The pumps and fans inverter Model Varispeed G7 Varispeed F7 Varispeed L7 Varispeed E7 Note: For detailed information please refer to Varispeed G7/F7/L7/E7 series section. B Cables Specifications Computer connecting cable Programmable console cable Model CS1W-CN226 CS1W-CN224 B Computer software Specifications PLC programming software: CX-programmer Inverter configurator software: CX-drive G7/F7/L7/E7 inverter PLC Model CX-One 375 Y203-EN2-02-Katalog.book Seite 376 Mittwoch, 24. Mai 2006 2:22 14 C Compobus/S slaves Product Digital I/O terminals Appearance Specifications 4 NPN inputs (+ common) 4 PNP inputs (– common) 4 NPN outputs (– common) 4 PNP outputs (+ common) 8 NPN inputs (+ common) 8 PNP inputs (– common) 8 NPN outputs (– common) 8 PNP outputs (+ common) 16 NPN inputs (+ common) 16 PNP inputs (– common) 16 NPN outputs (– common) 16 PNP outputs (+ common) 8 Relay outputs 8 Power MOS FET relay outputs Model SRT2-ID04 SRT2-ID04-1 SRT2-OD04 SRT2-OD04-1 SRT2-ID08 SRT2-ID08-1 SRT2-OD08 SRT2-OD08-1 SRT2-ID16 SRT2-ID16-1 SRT2-OD16 SRT2-OD16-1 SRT2-ROC08 SRT2-ROF08 16 Relay outputs 16 Power MOS FET relay outputs SRT2-ROC16 SRT2-ROF16 Analog input terminal 4 NPN inputs (+ common) 4 PNP inputs (– common) 4 NPN outputs (– common) 4 PNP outputs (+ common) 8 NPN inputs (+ common) 8 PNP inputs (– common) 8 NPN outputs (– common) 8 PNP outputs (+ common) 1 to 4 inputs (set with DIP switch) SRT2-ID04CL SRT2-ID04CL-1 SRT2-OD04CL SRT2-OD04CL-1 SRT2-ID08CL SRT2-ID08CL-1 SRT2-OD08CL SRT2-OD08CL-1 SRT2-AD04 Analog output terminal 1 or 2 outputs (set with DIP switch) SRT2-DA02 Relay output terminals Waterproof terminals Note: For detailed information about Compobus/S slaves, please refer to catalogue No. Y201-EN2-02 AS. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. I25E-EN-02 376 In the interest of product improvement, specifications are subject to change without notice. 3G3RV-P10ST@-E
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2006:05:31 09:46:28+02:00 Modify Date : 2006:05:31 10:04:18+03:00 Producer : Acrobat Distiller 7.0.5 (Windows) Mod Date : 2006:05:31 10:04:18+03:00 Creation Date : 2006:05:31 09:46:28+02:00 Author : smach Metadata Date : 2006:05:31 10:04:18+03:00 Creator Tool : FrameMaker 6.0 Document ID : uuid:e0456a6c-9be0-46c2-a2a1-b88a85269ef6 Instance ID : uuid:c36f6060-eaae-46d4-a357-94e87914f697 Format : application/pdf Title : Y203-EN2-02+Motion&Drives+Catalogue Creator : smach Has XFA : No Page Count : 12EXIF Metadata provided by EXIF.tools