Omron Hem 640 E Users Manual
HEM-640-E to the manual 24e25ca0-2c82-462d-bf27-95af1c94440c
2015-01-24
: Omron Omron-Hem-640-E-Users-Manual-332432 omron-hem-640-e-users-manual-332432 omron pdf
Open the PDF directly: View PDF .
Page Count: 18
Instruction manual page 1
Gebrauchsanweisung Seite 17
Gebruiksaanwijzing pagina 33
Mode d’emploi page 49
Manuale de instructone pagina 65
Manual de instrucciones pagina 81
RX-3
Blood Pressure Monitor
IM-HEM-640-E-01-08/08
1628088-1E
28070122-06 RX-3 Cover 14-08-2008 15:48 Pagina 1
1
RX-3 English
Introduction
The OMRON RX-3 measures your blood pressure and pulse simply and quickly from the wrist, without the use
of an inflation bulb or stethoscope. The measurement values are stored in the memory of the OMRON RX-3.
The OMRON RX-3 fits wrist circumferences from 13.5 to 19.5 cm.
28070106 RX-3 GB 01-16 14-08-2008 15:36 Pagina 1
RX-3 English
2
General
• The OMRON RX-3 is not suitable for measuring
the frequency of cardiac pacemakers.
• Consult your doctor during pregnancy, arrhythmia
and arteriosclerosis.
• Avoid eating, drinking (alcohol), smoking, sport
and taking a bath before measurement.
• Be calm and relaxed before and during
measurement.
• You should never change the dose of medicines
prescribed by your doctor.
Tips for use
• Check your blood pressure at least twice a day
(before breakfast, after work).
• Do not measure your blood pressure while you
are in a vehicle.
• Always measure on the same wrist.
•Wrap the wrist cuff around your wrist before start
of measurement.
Caution
• Operating temperature between 10°C and 40°C.
• Operating environment must be free from
excessive vibrations, shocks, magnetic fields,
electrical noise, etc.
• Stay out of sunlight during measuring.
• Keep portable phones 5 meters away during
measurement.
• Do not wrap the cuff other than around your wrist.
• Do not drop the OMRON RX-3.
How to obtain meaningful blood pressure readings
28070106 RX-3 GB 01-16 14-08-2008 15:36 Pagina 2
3
RX-3 English
Overview
A
D
E
C
B
ADisplay
BWrist Cuff
CMemory Recall button
DOn/Off button
EBatteryCompartment
28070106 RX-3 GB 01-16 14-08-2008 15:36 Pagina 3
RX-3 English
4
Preparation
3Close the battery compartment.
Insert batteries
1Open the batterycompartment. 2Inserttwobatteries in the battery compartment.
Caution! Use twoidentical 1.5V alkaline
batteries type AAA LR03!
28070106 RX-3 GB 01-16 14-08-2008 15:36 Pagina 4
RX-3 English
5
Fit wrist cuff
Caution! Do not press On/Off button when the wrist cuff is not wrapped around the wrist!
M
1Bare your wrist.
Caution!Push up your sleeve: avoid constricting
the blood flow!
2Put the monitor on the inner side of your wrist.
3Hold the end of the wrist cuff and wrap it around
your wrist.
Caution! Be sure the wrist cuff fits closely; do
not pinch your arm!
Note:attach the monitor upside down for reliable
measurement at your right wrist.
28070106 RX-3 GB 01-16 14-08-2008 15:36 Pagina 5
RX-3 English
6
Control functions
CMemoryRecall button
DOn/Off button
Measurement
FSystolic blood pressure in mmHg.
GMonitor blood pressure: flash - measurement
takes place, light up - finish measurement.
HDiastolic blood pressure in mmHg.
JMemory display: values in memory.
KMemory position: 1 to 28.
LInflation: wrist cuff inflates and measurement starts.
MDeflation: wrist cuff deflates and measurement
finishes.
NBattery exhausted: batteries are weak/exhausted.
PPulse: heartbeats per minute.
Operation
SYSmmHg MEMORY
PULSE
/min
DI AmmHg
C
D
F
H
G
P
J
N
M
L
K
28070106 RX-3 GB 01-16 14-08-2008 15:36 Pagina 6
7
RX-3 English
Caution! Allow an interval of at least three minutes between two successive measurements!
SYSmmHg MEMORY
PULSE
/min
DIA mmHg
SYSmmHg MEMORY
PULSE
/min
DI AmmHg
1Sit comfortably at a table with your feet flat on the
floor and put your armagainst the hard case.
Caution! The OMRON RX-3 should always be at
heartheight during measurement. Usage of the hard
case assures the right position of the OMRON RX-3!
2Press On/Off button to start measurement.
The OMRON RX-3 measures during inflation!
Caution ! Sit still, do not move, do not speak and
do not touch the OMRON RX-3!
28070106 RX-3 GB 01-16 14-08-2008 15:36 Pagina 7
RX-3 English
8
1Read the values of blood pressure and pulse from the display.
Note: Displayshows alternately blood pressures and heartbeats.
Read display
2Note values in your personal blood pressure pass.3Press On/Off button to turnoff power.
SYSmmHg MEMORY
PULSE
/min
DI AmmHg
SYSmmHg MEMORY
PULSE
/min
DI AmmHg
SYSmmHg MEMORY
PULSE
/min
DI AmmHg
28070106 RX-3 GB 01-16 14-08-2008 15:36 Pagina 8
RX-3 English
9
Memory
SYSmmHg MEMORY
PULSE
/min
DI AmmHg
SYSmmHg MEMORY
PULSE
/min
DI AmmHg
K
Recall previous values K Memory position of latest and previous values.
2Press Memory Recall button for latest and previous values. Press On/Off button to turn off power.
Note: Displayshows alternately blood pressures and heartbeats.
SYSmmHg MEMORY
PULSE
/min
DI AmmHg
K
SYSmmHg MEMORY
PULSE
/min
DI AmmHg
1Press MemoryRecall button to turn on power. Note:Displayshows alternately blood pressures and heartbeats.
28070106 RX-3 GB 01-16 14-08-2008 15:36 Pagina 9
RX-3 English
10
Erase memory
1Press MemoryRecall button to turn on power. 2Press MemoryRecall button and simultaneously
On/Off button to erase memory.
Caution! All stored values will be erased!
Press On/Off button to turn off power.
SYSmmHg MEMORY
PULSE
/min
DI AmmHg
SYSmmHg MEMORY
PULSE
/min
DI AmmHg
28070106 RX-3 GB 01-16 14-08-2008 15:36 Pagina 10
11
RX-3 English
• Store the OMRON RX-3 in the hard case in a dry, closed place with a temperature between -20°C and 60°C.
• Remove the batteries if you not intend to use the OMRON RX-3 for 3 months or more.
Storage
Faults: causes and rectifications
Fault Cause Rectification
Correct reading not possible Movement, sound vibration, Wait for at least three minutes to
weak pulse repeat measurement
Display Low voltage Batteries weak/exhausted Fit two new identical 1.5V
alkaline empty batteries type AAA LR03
Inexplicable values Wrong working method Follow instructions, repeat
measurement
28070106 RX-3 GB 01-16 14-08-2008 15:36 Pagina 11
RX-3 English
12
Maintenance and spare parts
• Use a soft, slightly moistened cloth to clean the
OMRON RX-3.
Caution! Do not use petrol, thinners or similar
solvents!
•Use a soft, moistened cloth and soap to clean the
wrist cuff.
Caution! Do not wash the wrist cuff!
Caution! Do not use petrol, thinners or similar
solvents!
• Do not carry out repairs of any kind yourself. If a
defect occurs consult your OMRON retail outlet or
distributor as mentioned on the packaging.
Calibration
• It is recommended to have the OMRON RX-3
inspected every two years to ensure correct
function and accuracy. Consult your OMRON
retail outlet or OMRON distributor as mentioned
on the packaging.
Replace batteries
• Remove the battery out of the battery
compartment and insert two new identical 1.5V
alkaline batteries type AAA LR03 batteries.
Spare parts
•Due to high company quality standards, OMRON
considers the main unit as a non-serviceable part
because the need for proper calibration after
replacement of high tech components.
• If the cuff needs to be replaced havethis done by
an authorised expert. Consult your OMRON
retailer or OMRON distributor as mentioned on
the packaging.
Attention! Disposal of batteries
and the OMRON RX-3 should be
carried out in accordance with the
national regulations for the
disposal of electronic products.
28070106 RX-3 GB 01-16 14-08-2008 15:36 Pagina 12
RX-3 English
13
Technical Data
Product name OMRON RX-3 wrist blood pressure monitor
Model HEM-640-E
Display Digital LCD
Measuring range Blood pressure: 0 - 299 mmHg / Pulse: 40 - 180 beats/minute
Accuracy Blood pressure: ± 3 mmHg / Pulse: ± 5% of display reading
Inflation Automatic by electric pump
Deflation Automatic rapid deflation system
Pressure detection Pressure sensor (capacitive)
Measuring method Oscilliometric
Memory 28 Measurements
Power supply 2 x 1.5V Alkaline batteries (LR03) AAA
Battery life New batteries will last for approx. 300 measurements
Operating temperature /humidity +10°C to +40°C / 30% to max. 85% relative humidity
Operating environment Free from excessive vibrations, shocks, magnetic fields, electrical noise, etc.
Storage temperature / humidity -20°C to +60°C /10% to max. 95% relative humidity
Weight Approx. 140/160 g ex-/including batteries
Outer dimensions Approx. 47 mm (W) x 71 mm (H) x 79 mm (D)
Wrist circumference Approx. 13.5 cm to 19.5 cm
Accessories Instruction manual, guarantee card, blood pressure pass,
2alkaline batteries, storage box
Note Subject to technical modification without prior notice
=Type B 0197
Manufacturer OMRON HEALTHCARE CO., LTD. Japan
EU-representative OMRON HEALTHCARE EUROPE B.V., Kruisweg 577, NL-2132 NA Hoofddorp
Made in China
This device fulfils the provisions of the EC directive 93/42/EEC (Medical Device Directive). This blood pressure monitor is designed
according to the European standard EN1060, Non-invasive sphygmomanometers Part 1: General Requirements and Part 3:
Supplementaryrequirements for electromechanical blood pressure measuring systems.
This OMRON product is produced under the strict quality system of OMRON HEALTHCARE CO., LTD., Japan. The Core component for
OMRON blood pressure monitors, which is the Pressure Sensor, is produced in Japan.
28070106 RX-3 GB 01-16 14-08-2008 15:36 Pagina 13
RX-3 English
14
Blood circulation
The blood circulation is responsible for supplying the
body with oxygen. Blood pressure is the pressure
exerted on the arteries.
The systolic blood pressure value (higher pressure
or top value) represents the blood pressure
produced bycontraction of the heart muscle.
The diastolic blood pressure value (lower pressure
or lower value) represents the blood pressure
produced by relaxation of the heart muscle.
Classification of blood pressure
The World Health Organisation (WHO) and the
International Society of Hypertension (ISH)
developed the blood pressure classification. This
classification is based on the blood pressure values
measured while sitting on a chair in the outpatient
department of a hospital. According to the blood pressure classification by the WHO/ISH.
General information about blood pressure
Optimal blood
pressure
(target value)
Normal blood
pressure
Normal systolic value
Mild hypertension
Moderate hypertension
Severe hypertension
Systolic blood pressure
(mmHg)
Diastolic
blood
pressure
(mmHg)
80
180
160
140
130
120
85 90 100 110
28070106 RX-3 GB 01-16 14-08-2008 15:36 Pagina 14
RX-3 English
15
Health and blood pressure
The incidence of hypertension increases with age. In
addition, a lack of exercise, excess body fat and high
levels of cholesterol (LDL), which sticks to the inside
in blood vessels, reduces elasticity of these vessels.
Hypertension accelerates arterial sclerosis which
can lead to very serious conditions such as stroke
and myocardial infarction. For these reasons it is
very important to know whether the blood pressure
is within a healthy range.Blood pressure fluctuates
from minute to minute, throughout the day. Therefore
it is essential to takeregular measurements to help
you identify an average blood pressure.
Symptoms of high blood pressure
High blood pressure can go unnoticed for a long
time, since it does not cause noticeable symptoms.
The following are all possible causes of abnormally
high blood pressure:
•Overweight
•High cholesterol level
• Smoking
• Excessivealcohol consumption
• Stress and emotional upset
• Excessive consumption of salt
• Lack of physical exercise
• Genetic/hereditary predisposition
• Underlying illnesses, such as kidney disorders or
endocrine disturbance
Blood pressure measurement
Measuring your blood pressure daily enables you to
recognizehigh blood pressure at an early stage and
obtain medical treatment.
The oscillometric method of measurement
determines your blood pressure by measuring the
pressure fluctuations caused by the pulse waves.
Since your blood pressure fluctuates within a day (see
graphic next page), you should always measure it at the
same time each day to ensure that the measurements
are genuinely comparable. At the doctor’s surgery,
nervousness and tension may cause your blood
pressure to be higher than in familiar circumstances at
home.This is known as “White Coat Hypertension”.
28070106 RX-3 GB 01-16 14-08-2008 15:36 Pagina 15
RX-3 English
16
Treatment of high blood pressure
If your blood pressure reaches upper values of 140 -
160 mmHg and lower values of 90 - 95 mmHg in
repeated measurements over several days, you
should consult your doctor for detailed medical
examination.You can assist the treatment
prescribed by your doctor in the following ways:
• Loose weight and lower your cholesterol level by
reducing the calories and fat in your diet. Cut down
on animal fats and eat more fruit and vegetables.
• Reduce the consumption of alcohol.
• Reduce the intakeof salt: the German League
for Combating High Blood Pressure recommends
six grams of salt per day (i.e. one teaspoon) on
average.
• Stop smoking.
• Take regular exercise.
• Monitor your blood pressure.Example: fluctuation within a day (male, 35 years old)
mmHg
200
150
100
50
6 12 18 24
Upper curve: systolic blood pressure
Lower curve: diastolic blood pressure
Time of day
28070106 RX-3 GB 01-16 14-08-2008 15:36 Pagina 16
OMRON HEALTHCARE CO., LTD.
24, Yamanouchi Yamanoshita-cho, Ukyo-ku
Kyoto, 615-0084 Japan
OMRON HEALTHCARE EUROPE B.V.
Kruisweg 577, 2132 NA Hoofddorp, The Netherlands
www.omron-healthcare.com
OMRON DALIAN CO., LTD.
Economic & Technical Development Zone, Dalian 116600, China
OMRON HEALTHCARE UK LTD.
Opal Drive, Fox Milne, Milton Keynes MK15 0DG, United Kingdom
OMRON Medizintechnik Handelsgesellschaft mbH
John-Deere-Str.81a, 68163 Mannheim, Germany
www.omron-medizintechnik.de
OMRON SANTÉ FRANCE SAS
14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, France
Made in China
Manufacturer
EU-representative
Production facility
Subsidiary
EC REP
28070122-06 RX-3 Cover 14-08-2008 15:48 Pagina 2