Omron M3 It Users Manual HEM 7131U E_A_M_EN
M3 IT to the manual 8dda2644-4ba4-45d0-81d2-404cd818c572
2015-01-24
: Omron Omron-M3-It-Users-Manual-332454 omron-m3-it-users-manual-332454 omron pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
1. Know Your Device Contents: Monitor, arm cuff, instruction manual, storage case, battery set, USB cable, blood pressure pass Automatic Blood Pressure Monitor Monitor: H IM-HEM-7131U-E-EN-01-08/2013 2298868-3A Introduction Thank you for purchasing the OMRON M3 IT Automatic Blood Pressure Monitor. The OMRON M3 IT is a compact, fully automatic blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly. For comfortable controlled inflation without the need of pressure pre-setting or re-inflation the device uses its advanced “IntelliSense” technology. Intended Use This device is a digital monitor intended for use in measuring blood pressure and pulse rate in adult patient population who can understand this instruction manual with the arm circumference range printed on the arm cuff. The device detects the appearance of irregular heartbeats during measurement and gives a warning signal with the measurement result. B C D A. B. C. D. E. F. G. Display Memory button START/ STOP button Date/ Time setting button USER ID selection switch Cuff wrap guide lamp Up/ Down buttons H. Blood pressure colour indicator I. Battery compartment J. AC adapter jack (for optional AC adapter) K. USB port L. Air jack Arm cuff: M M. Arm cuff (Arm circumference 22 - 42 cm) N. Air plug O. Air tube N Important Safety Information Caution: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property. (General Usage) Always consult your physician. Self-diagnosis of measurement results and self-treatment are dangerous. People with severe blood flow problems, or blood disorders, should consult a physician before using the device, as the arm cuff inflation can cause bruising. If there are any abnormalities during the measurement, remove the arm cuff. Do not use this device on infants or persons who cannot express their intentions. Do not inflate the arm cuff more than necessary. Do not use the device for any purpose other than measuring blood pressure. Use only the approved arm cuff for this device. Use of other arm cuffs may result in incorrect measurement results. Do not use a mobile phone or other devices that emit electromagnetic fields, near the device. This may result in incorrect operation of the device. Do not disassemble the monitor or arm cuff. Do not use in a location with moisture, or a location where water may splash on the device. This may damage the device. Do not use the device in a moving vehicle (car, airplane). Do not take measurements more than necessary. It may cause bruising due to blood flow interference. Consult your physician before using the device if you had a mastectomy. (AC Adapter (optional) Usage) Fully insert the power plug into the outlet. When disconnecting the power plug from the outlet, do not pull the power cord. Be sure to pull from the power plug safely. When handling the power cord, take care not to do the following: Do not damage. Do not break it. Do not tamper with it. Do not forcibly bend or pull. Do not twist. Do not bundle during use. Do not pinch. Do not place under heavy objects. Wipe the dust off from the power plug. Unplug monitor when not in use. Disconnect the power plug before cleaning. Use only the original adapter designed for this device. Use of unsupported adapters may damage and/or may be hazardous to the device. (Battery Usage) Do not insert the batteries with their polarities incorrectly aligned. Use only 4 “AA” alkaline or manganese batteries with this device. Do not use other types of batteries. Do not use new and used batteries together. Remove the batteries if the device will not be used for three months or more. General Precautions • Do not forcibly crease the arm cuff or the air tube excessively. • Do not press the air tube while taking a measurement. • To unplug the air plug, pull on the air plug at the connection with the monitor, not the tube itself. • Do not drop the monitor or subject device to strong shocks or vibrations. • Do not inflate the arm cuff when it is not wrapped around your arm. • Do not use the device outside the specified environment. It may cause an inaccurate result. • Read and follow the "Important information regarding Electro Magnetic Compatibility (EMC)" in the "6. Specifications". • Read and follow the "Correct Disposal of This Product" in "6. Specifications" when disposing of the device and any used accessories or optional parts. K O Display: P Y Q R Z AA S AB T AC U AD V AE W AF X P. Q. R. S. T. U. V. W. X. OK symbol Transfer indicator USER ID symbol DATA/FULL symbol Systolic blood pressure Diastolic blood pressure Low battery symbol Cuff wrap guide Heartbeat symbol (Flashes during measurement.) Y. Memory symbol Z. Average value symbol AA. Date/Time display AB. Movement error symbol AC. Irregular heartbeat symbol AD. Blood pressure level indicator AE. Deflation symbol AF. Pulse display / Memory number 3. Replace the battery cover. To View the Measurement Values Stored in Memory • When the low battery symbol ( ) appears on the display, turn the monitor off, then replace all batteries at the same time. Long life alkaline batteries are recommended. • The measurement values continue to be stored in memory even after the batteries are replaced. • The supplied batteries may have a shorter life. Disposal of used batteries should be carried out in accordance with the national/local regulations for the disposal of batteries. 3.3 Taking a Measurement Notes: • To cancel a measurement, press the START/STOP button to release the air in the arm cuff. • Remain still while taking a measurement. The monitor is designed to take measurements and store the measurement values in the memory for 2 people using USER ID 1 and USER ID 2. Set the monitor to the correct date and time before taking a measurement for the first time. 1. Select your User ID (1 or 2). 1. Press the button. 2. Push or to change the year Push button to confirm the year and then the month flashes. Repeat the same steps to change the month, day, hour, and minutes. Year Month Day Hour Change Confirm Minute : Forward : Back ) The movement error symbol is displayed if you move your body during the measurement. Please remove the arm cuff, and wait 2 - 3 minutes. Take another measurement, remain still during measurement. START INFLATE DEFLATE COMPLETE Cuff Wrap Guide Lamp Change Confirm 3. Press the START/STOP button to turn the monitor off. Notes: • If the batteries have been replaced, the date and time setting will need to be reset. • If the date and time are not set, “-:--” appears during or after measurement. Remove tight-fitting clothing or tight rolled up sleeve from your left upper arm. Do not place the arm cuff over thick clothes. 1. Insert the air plug into the air jack securely. * JNC7: The Seventh Report, 2003 Dec, of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of Hi Blood Pressure. 1. Select your User ID (1 or 2). 2. Press and hold the button for more than 3 seconds. If your systolic pressure is more than 210 mmHg After the arm cuff starts to inflate, press and hold the START/ STOP button until the monitor inflates 30 to 40 mmHg higher than your expected systolic pressure. 3. Using the Device 3.1 Applying the Arm Cuff Notes: • If the previous measurement was taken without setting the date and time, the average value is not calculated. • If there are no measurements results stored in the memory, the screen to the right is displayed. Notes: • The monitor will not inflate above 299 mmHg. • Do not apply more pressure than necessary. 3. Remove the arm cuff. 4. Press the START/STOP button to turn the monitor off. Note: Wait 2-3 minutes before taking another measurement. Waiting between measurements allows the arteries to return to the condition prior to taking a measurement. To Transfer the Measurement Values To begin using the Medical Link software for the first time, please visit www.omron-healthcare.com for the initial set-up instructions. 1. Open the USB port cover. 2. Apply the arm cuff to your left upper arm. Using the Guest Mode The monitor stores measurement values for 2 users in the memory. The guest mode can be used to take a single measurement for another user. No measurement values are stored in the memory when the guest mode is selected. 2. Connect the USB cable to a PC. 1. Press and hold the START/STOP button for more than 3 seconds. The bottom edge of the arm cuff should be 1 to 2 cm above the elbow. Air tube is on the inside of your arm and aligned with your middle finger. The USER ID symbol and the Date/Time display will disappear. 3. Connect the USB cable to the monitor. 1 - 2 cm 2. Release the START/STOP button when the Date/Time display turns off. The arm cuff will start to inflate automatically. 3. Secure closed with the fabric fastener. Always consult your physician. Self-diagnosis of measurement results and self-treatment are dangerous. To Delete All the Values Stored in Memory 1. Select your User ID (1 or 2). 2. Press the Memory button, while the memory symbol ( ) appears. 3. While holding the Blood Pressure Colour Indicator These are form statistical values for blood pressure. or button to view the values stored in memory. : To the older values : To the more recent values Change Confirm ) The JNC7* Guideline recommends the following guideline. General Guidelines for Blood Pressure Prehypertension at Office Hypertension at Home Systolic Blood Pressure 120 - 139 mmHg 135 mmHg Diastolic Blood Pressure 80 - 89 mmHg 85 mmHg Note: The cuff wrap guide result appears on the display with the measurement values. The cuff wrap guide lamp will not light. : The arm cuff was wrapped snugly enough. : The arm cuff was loose or not wrapped correctly. To View the Average Value If the cuff was wrapped too loosely, it may cause unreliable values. If the wrapping of cuff is too loose, the cuff wrap guide lamp does not light. Otherwise lights in green. This is the function which is used as an aid in determining if the cuff is wrapped snugly enough. If your systolic or diastolic pressure is above the standard range (135 mmHg for the systolic blood pressure and/or 85 mmHg for the diastolic blood pressure), the blood pressure colour indicator will light in orange when the measurement result is displayed. If they are within the standard range, no light will appear. Alternating date/ time display 3. Press the The arm cuff will start to inflate automatically. Change Confirm ) The average value symbol is displayed when you press and hold the memory button for more than 3 seconds. The most recent average value appears on the display screen. The Memory number appears for a second before the pulse rate is displayed. The newest set is numbered “1”. 2. Press the START/ STOP button. Change Confirm ) Normal Heartbeat When the monitor detects an irregular Pulse rhythm two or more times during the Blood pressure measurement, the irregular heartbeat Irregular Heartbeat symbol ( ) will appear on the display Short Long with the measurement values. Pulse An irregular heartbeat rhythm is defined Blood pressure as a rhythm that is 25% less or 25% more than the average rhythm detected while the monitor is measuring the systolic and diastolic blood pressure. If the irregular heartbeat symbol ( ) displays with your measurement results, we recommend you consult your physician. Follow the directions of your physician. Cuff Wrap Guide Lamp ( 1. Select your User ID (1 or 2). 2. Press the button. The monitor automatically stores the measurement result in its memory. It will automatically turn off after 2 minutes. Irregular Heartbeat Symbol ( Average Value Symbol ( Notes: • If there are only 2 measurement values in the memory for that period, the average will be based on these 2 values. • If there is 1 measurement value in the memory for that period, this is displayed as the average. • If the memory is full, the monitor will delete the oldest value. • When viewing the measurement value taken without setting the date and time, “-:--” is displayed instead of the date and time. Notes: Display symbols: Movement Error Symbol ( The monitor automatically stores the results up to 60 sets for each user (1 and 2). It can also calculate an average value based on the last 3 measurement values taken within 10 minutes. • Sit on a chair with your feet flat on the floor. • Sit upright with your back straight. • Sit with your back and arm being supported. • The arm cuff should be placed on your arm at the same level as your heart. 2.2 Setting the Date and Time Please read this instruction manual thoroughly before using the device. Please keep for future reference. For specific information about your own blood pressure, CONSULT YOUR PHYSICIAN. Warning: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. (General Usage) Consult your physician before using the device in pregnancy including pre-eclampsia, or if diagnosed with arrhythmia or arteriosclerosis. Do not use the device on the injured arm or the arm under medical treatment. Do not apply the arm cuff on the arm while being on an intravenous drip or blood transfusion. Consult your physician before using the device on the arm with an arterio-venous (A-V) shunt. Do not use the device with other medical electrical (ME) equipment simultaneously. Do not use the device in the area the HF surgical equipment, MRI, or CT scanner exists, or in the oxygen rich environment. The air tube or the AC adapter cable may cause accidental strangulation in infants. Contained small parts that may cause a choking hazard if swallowed by infants. (AC Adapter (optional) Usage) Do not use the AC adapter if the device or the power cord is damaged. Turn off the power and unplug the power cord immediately. Plug the AC adapter into the appropriate voltage outlet. Do not use in a multi-outlet plug. Never plug in or unplug the power cord from the electric outlet with wet hands. L 1. Remove the battery cover. indicated in the battery compartment. J G D F E 3.4 Using the Memory Function To take a measurement, you need to be relaxed and comfortably seated, under comfortable room temperature. Avoid bathing, drinking alcohol or caffeine, smoking, exercising or eating 30 minutes before taking a measurement. 2. Insert 4 “AA” batteries as I A Model M3 IT Instruction Manual 3.2 How to Sit Correctly 2. Preparation 2.1 Battery Installation Notes: • When you take a measurement on the right arm, the air tube will be at the side of your elbow. Be careful not to rest your arm on the air tube. • The blood pressure can differ between the right arm and the left arm, and therefore also the measured blood pressure values can be different. OMRON recommends to always use the same arm for measurement. If the values between both arms differ substantially, please check with your physician which arm to use for your measurement. button down, press the START/STOP button for more than 3 seconds. Note: You cannot partially delete the values stored in the memory. All values for the user you select will be deleted. 4. Error Messages and Troubleshooting 5. Maintenance and Storage 5.1 Maintenance 4.1 Error Messages Error Display Cause Irregular heartbeats are detected. Movement during measurement. The batteries are low. The batteries are exhausted. Solution Remove the arm cuff. Wait 2 - 3 minutes and then take another measurement. Repeat the steps in section 3.3. If this error continues to appear, contact your physician. Carefully read and repeat the steps in section 3.3. To protect your device from damage, please observe the following: • Store the device and the components in a clean, safe location. • Do not use any abrasive or volatile cleaners. • Do not wash the device and any components or immerse them in water. • Do not use petrol, thinners or similar solvents to clean the device. You should replace the batteries with new ones at once. Refer to section 2.1. Insert the plug securely. Refer to section 3.1. Arm cuff is applied too loosely. Apply the arm cuff tighter. Refer to section 3.1. Replace the cuff with a new one. Refer to section 5.3. Repeat measurement. Remain still and do not talk during measurement. Movement during measurement Refer to section 3.3. and the arm cuff has not been If “E2” appears repeatedly, inflated sufficiently. inflate the cuff manually until it is 30 to 40 mmHg above your previous measurement result. Refer to section 3.3. The arm cuff was inflated above Do not inflate the cuff above 299 mmHg. 299 mmHg when inflating the Refer to section 3.3. cuff manually. Repeat measurement. Remain still and do not talk during Movement during measurement. measurement. Refer to section 3.3. Clothing is interfering with the arm cuff. Remove any clothing interfering with the arm cuff. Refer to section 3.1. Device error. Contact your OMRON retail outlet or distributor. • Use a soft and dry cloth, or a soft and moistened cloth and neutral soap to clean on the monitor and the arm cuff. • Changes or modification not approved by the manufacturer will void the user warranty. Do not disassemble or attempt to repair the device or components. Consult your authorised OMRON retail outlet or distributor. Calibration and Service • The accuracy of this blood pressure monitor has been carefully tested and is designed for a long service life. • It is generally recommended to have the device inspected every 2 years to ensure correct functioning and accuracy. Please consult your authorised OMRON retail outlet or distributor. Arm cuff is applied too loosely. The measurement result is extremely high (or low). Movement or talking during measurement. Apply the arm cuff tighter. Refer to section 3.1. Remain still and do not talk during measurement. Refer to section 3.3. Keep the device in its storage case when not in use. 1. Unplug the air plug from the air jack. 2. Gently fold the air tube into the arm cuff. Remove any clothing interfering with the arm cuff. Refer to section 3.1. The cuff wrapping guide lamp does not light. Arm cuff deflates too soon. The arm cuff is loose. Apply the cuff correctly so that it is firmly wrapped around the arm. Refer to section 3.1. Cannot measure or The arm cuff has not been the results are too low inflated sufficiently. or too high. The batteries are empty. Do not store the device in the following situations: •If the device is wet. •Locations exposed to extreme temperatures, humidity, direct sunlight, dust or corrosive vapours. •Locations exposed to vibrations, shocks or where it will be at an angle. Nothing happens when you press the buttons. 5.3 Optional Medical Accessories Arm cuff Arm circumference 22 - 42 cm AC adapter Other problems. Insert the batteries with the correct (+/-) polarity. Refer to section 2.1. • Press the START/STOP button and repeat measurement. • Replace the batteries with new ones. If the problem continues, contact your OMRON retail outlet or distributor. Inflation Fuzzy-logic controlled by electric pump Deflation Automatic pressure release valve Memory 60 measurements with date and time for each user (1 and 2) Rating DC6V 4W Power source 4 “AA” batteries 1.5V or optional AC adapter (Adapter S-9515336-9, INPUT AC100-240V 50/60Hz 0.12A) (Adapter UK-9983666-5, INPUT AC100-240V 50/60Hz 15VA) Battery life Approx. 1000 measurements (using new alkaline batteries) = Type BF Protection against electric shock Internally powered ME equipment (When using only the batteries) Operating temperature/ humidity +10 to +40°C / 30 to 85% RH Storage temperature/ humidity/ air pressure -20 to +60°C / 10 to 95% RH / 700 to 1060 hPa IP classification IP 20 Weight Monitor: Approx. 280 g without batteries Arm cuff: Approx. 170 g Outer dimensions Monitor: Approx. 107 (w) mm x 79 (h) mm x 141 (l) mm Arm cuff: Approx. 145 mm x 594 mm = Class II ME equipment (Optional AC adapter) Easy Cuff L 9911729-4 (Model: HEM-RML31) Adapter S 9515336-9 The guarantee does not cover any of the following: a. Transport costs and risks of transport. b. Costs for repairs and / or defects resulting from repairs done by unauthorised persons. c. Periodic check-ups and maintenance. d. Failure or wear of optional parts or other attachments other than the main device itself, unless explicitly guaranteed above. e. Costs arising due to non-acceptance of a claim (those will be charged for). f. Damages of any kind including personal caused accidentally or from misuse. g. Calibration service is not included within the guarantee. h. Optional parts have a one (1) year warranty from date of purchase. Optional parts include, but are not limited to the following items: Cuff and Cuff Tube, AC Adapter, USB Cable. Should guarantee service be required please apply to the dealer whom the product was purchased from or an authorised OMRON distributor. For the address refer to the product packaging / literature or to your specialised retailer. If you have difficulties in finding OMRON customer services, contact us for information. www.omron-healthcare.com Cuff circumference 22 to 42 cm Repair or replacement under the guarantee does not give rise to any extension or renewal of the guarantee period. The guarantee will be granted only if the complete product is returned together with the original invoice / cash ticket issued to the consumer by the retailer. Manufacturer OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN EU-representative OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www.omron-healthcare.com Production facility OMRON (DALIAN) CO., LTD. Dalian, CHINA Subsidiary OMRON HEALTHCARE UK LTD. Opal Drive, Fox Milne, Milton Keynes, MK15 0DG, U.K. Cuff/ Tube material Nylon, polyester, polyvinyl chloride Monitor, arm cuff, instruction manual, storage case, battery set, USB cable, blood pressure pass In order to regulate the requirements for EMC (Electro Magnetic Compatibility) with the aim to prevent unsafe product situations, the EN60601-1-2:2007 standard has been implemented. This standard defines the levels of immunity to electromagnetic interferences as well as maximum levels of electromagnetic emissions for medical devices. This medical device manufactured by OMRON HEALTHCARE conforms to this EN60601-1-2:2007 standard for both immunity and emissions. Nevertheless, special precautions need to be observed: Adapter UK 9983666-5 5.4 Other Optional/Replacement Parts USB cable USB cable 9517499-4 Using the Optional AC Adapter The batteries have been inserted incorrectly. Pressure: ±3 mmHg Pulse: ±5% of display reading Important information regarding Electro Magnetic Compatibility (EMC) With the increased number of electronic devices such as PC’s and mobile (cellular) telephones, medical devices in use may be susceptible to electromagnetic interference from other devices. Electromagnetic interference may result in incorrect operation of the medical device and create a potentially unsafe situation. Medical devices should also not interfere with other devices. Inflate the cuff so that it is 30 to 40 mmHg above your previous measurement result. Refer to section 3.3. Replace the batteries with new ones. Refer to section 2.1. Accuracy • This device fulfils the provisions of EC directive 93/42/EEC (Medical Device Directive). • This blood pressure monitor is designed according to the European Standard EN1060, Non-invasive sphygmomanometers Part 1: General Requirements and Part 3: Supplementary requirements for electromechanical blood pressure measuring systems. • This OMRON product is produced under the strict quality system of OMRON HEALTHCARE Co. Ltd., Japan. The Core component for OMRON blood pressure monitors, which is the Pressure Sensor, is produced in Japan. Arm cuff pressure does not rise. Replace the arm cuff with a new one. Refer to section 5.3. Measurement range Pressure: 0 to 299 mmHg Pulse: 40 to 180 beats/min. Thank you for buying an OMRON product. This product is constructed of high quality materials and great care has been taken in its manufacturing. It is designed to give you every satisfaction, provided that it is properly operated and maintained as described in the instruction manual. This product is guaranteed by OMRON for a period of 3 years after the date of purchase. The proper construction, workmanship and materials of this product is guaranteed by OMRON. During this period of guarantee OMRON will, without charge for labour or parts, repair or replace the defect product or any defective parts. OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH Gottlieb-Daimler-Strasse 10, 68165 Mannheim, GERMANY www.omron-healthcare.de OMRON SANTÉ FRANCE SAS 14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, FRANCE Make sure that the air tube The air connector is not securely connected into the is connected securely. Refer to section 3.1. air jack. Air is leaking from the arm cuff. Oscillometric method Note: Do not bend or crease the air tube excessively. (within the scope of EC Medical Device Directive 93/42/EEC) Clothing is interfering with the arm cuff. LCD Digital Display Measurement method Notes: • These specifications are subject to change without notice. • In the clinical validation study, the 5th phase was used on 85 subjects for determination of diastolic blood pressure. • This device has not been validated for use on pregnant patients. 5.2 Storage storage case. Solution OMRON M3 IT (HEM-7131U-E) Display Package contents 4.2 Troubleshooting Cause Model Applied part 3. Place the monitor and the arm cuff in the Problem 7. Warranty Product description Automatic Blood Pressure Monitor You should replace the batteries with new ones ahead of time. Refer to section 2.1. Air plug disconnected. Air is leaking from the arm cuff. 6. Specifications 1. Insert the AC adapter plug into the AC adapter jack on the rear side of the monitor. 2. Plug the AC adapter into an electrical outlet. To disconnect the AC adapter, unplug the AC adapter from the electrical outlet first and then remove the AC adapter plug from the monitor. • Do not use mobile (cellular) telephones and other devices, which generate strong electrical or electromagnetic fields, near the medical device. This may result in incorrect operation of the device and create a potentially unsafe situation. Recommendation is to keep a minimum distance of 7 m. Verify correct operation of the device in case the distance is shorter. Further documentation in accordance with EN60601-1-2:2007 is available at OMRON HEALTHCARE EUROPE at the address mentioned in this instruction manual. Documentation is also available at www.omron-healthcare.com. Correct Disposal of This Product (Waste Electrical & Electronic Equipment) This marking shown on the product or its literature, indicates that it should not be disposed of, with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this product from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can return this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal. Made in China
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Create Date : 2014:02:07 13:11:19+01:00 GTS PDFX Conformance : PDF/X-1a:2001 GTS PDFX Version : PDF/X-1:2001 Modify Date : 2014:02:07 13:12:09+01:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Creator : Title : HEM-7131U-E_A_M_EN Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2014:02:07 13:12:09+01:00 Producer : Acrobat Distiller 9.5.5 (Windows) Trapped : False Document ID : uuid:0b025e98-3263-4a88-8876-04632fab0833 Instance ID : uuid:7dc6a6ec-b328-427b-a5d8-ec47d2661b80 Rendition Class : default Version ID : 1 Schemas Namespace URI : http://ns.adobe.com/pdf/1.3/ Schemas Prefix : pdf Schemas Schema : Adobe PDF Schema Schemas Property Category : internal Schemas Property Description : A name object indicating whether the document has been modified to include trapping information Schemas Property Name : Trapped Schemas Property Value Type : Text Page Count : 2EXIF Metadata provided by EXIF.tools