Ondas Networks FS-757787 FullMAX User Manual FullMax V1 3
Full Spectrum Inc. FullMAX FullMax V1 3
User Manual
FullMAX BS1000, FS4000, MS40000 User Manual Version 1.3 FullMAX BS1000, FS4000, MS40000 User Manual Version 1.3 November 1, 2013 Full Spectrum Confidential FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Table of Contents FullMAX Description ...................................................................................... 4 1.1 System Description ............................................................................. 4 1.2 BS1000, FS4000 and MS4000 Hardware Architecture ....................... 5 1.3 FullMAX BS1000, FS4000 and MS4000 Software Architecture ........ 11 2 FullMAX BS1000, FS4000 and MS4000 Embedded Software Functionality12 3 FullMAX System Installation and Commissioning ........................................ 14 3.1 Enclosure of BS1000, FS4000 and MS4000 .................................... 14 3.2 Connecting the BS1000, FS4000 and MS4000 ................................ 14 3.3 FullMAX BS1000, FS4000 & MS4000 Tune Up and Alignment Procedures ...................................................................................................... 15 3.4 CLI Commands for BS1000, FS4000, MS4000 ................................ 16 3.5 Monitoring the BS / FS/ MS with the FullMAX NMS .......................... 17 4 FullMAX system operation ........................................................................... 18 4.1 Operation Restrictions / Information to User ..................................... 18 4.2 BS1000 Operation ........................................................................... 18 4.2.1 Main Group ................................................................................................... 18 4.2.2 mac-config .................................................................................................... 20 4.2.3 ul-config ........................................................................................................ 28 4.2.4 dl-config ........................................................................................................ 39 4.2.5 zone-config ................................................................................................... 44 4.2.6 bs-cap-config................................................................................................. 51 4.2.7 bs-burst-profile .............................................................................................. 52 4.2.8 bs-ss-action ................................................................................................... 55 4.2.9 ss-registered .................................................................................................. 57 4.2.10 ss-ip ........................................................................................................... 58 4.2.11 device ........................................................................................................ 60 4.2.12 Measurements ........................................................................................... 63 4.2.13 pkm–config ............................................................................................... 66 4.2.14 bs-private................................................................................................... 69 4.2.15 trap-config ................................................................................................. 75 4.2.16 lapc-config ................................................................................................ 78 4.3 FS4000 and MS4000 Operation ....................................................... 91 4.3.1 Main Group ................................................................................................... 91 4.3.2 ss-config ........................................................................................................ 92 4.3.3 device ............................................................................................................ 98 4.3.4 Measurements ............................................................................................. 102 4.3.5 ss-private ..................................................................................................... 105 4.3.6 ss-chconfig .................................................................................................. 110 4.3.7 ss-trap .......................................................................................................... 113 Full Spectrum Confidential FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Overview a) FullMAX is a point-to-multipoint (PtMP) broadband wireless system based on the WiMAX-e (IEEE 802.16e-2005) protocol with modifications which enable it to operate in the two (1) MHz channels which make up the 700 MHz A Guardband. The system includes a BS1000 Base Station, FS4000 Fixed Station and the MS4000 Mobile Station. The BS1000 is typically situated at an operator’s tower site with either an omni or sector base station antenna mounted on the tower and a coax cable running to the antenna port of the BS1000 base station. The Base Station data port (Ethernet) is then connected to a router which in turn is connected to a communications backhaul transport (fiber, microwave, leased line) which allows the data traffic to be carried to and from the operator’s network operation center (NOC). The Base Station can also operate independently of the backhaul transport. Fixed Stations are typically mounted at specific customer location with an external directional yagi antenna. Mobile Stations are moutned in vehicles with an external omni rooftop mounted “whip” antenna. The FullMAX system also includes a Network Management System (NMS) which allows the operator to monitor and configure the FullMAX network remotely. b) The main modifications to FullMAX relative to the IEEE802.16e-2005 air interface protocol are: 1) The RF front end can operate in the 700 MHz A Guardband which includes two frequency ranges: a. 757-758 MHz b. 787-788 MHz 2) The BS1000, FS4000 & MS4000 operate in 700 kHz wide channels inside the A Guardbands. 3) The BS1000, FS4000 and MS4000 have analog and digital filters which are designed to meet spectral mask for FCC Part 27 in the transmit direction and the channel selectivity in the receive direction. c) Outline of the document: 1) Paragraph 2: FullMAX system description 2) Paragraph 3: FullMAX system operation 3) Paragraph 4: BS1000, FS4000 and MS4000 installation and commissioning. Full Spectrum Confidential FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 1 FullMAX Description 1.1 System Description a) The FullMAX system architecture is described in figure 2-1 below. The system is used to establish private, multi-cell, Point to Multipoint broadband wireless service for electrical utilities and other mission critical industries. It supports both fixed and mobile applications. FullMAX Base Stations are typically installed at the operator’s existing Private Land Mobile Radio (PLMR) towers serving their respective cells. Wireless backhaul facilities are used to connect the Base Stations to the central site of the system. FullMAX fixed and mobile stations are deployed throughout the tower’s serving area. Utility Operation Equipment BS BS BS Central Hub Security Router FullMax Base Stations (1) NMS AAA Server DHCP server FullMax Operation Equipment (1) FullMax base station consists of 3 independent base station sectors and a base station hub Fig. 2-1: FullMAX system architecture b) FullMAX operates in unpaired spectrum using Time Division Duplex (TDD). FullMAX also operates in paired spectrum employing each portion of the paired spectrum as an independent unpaired spectrum. c) The FullMAX BS1000 is designed to support a single sector and as such, it supports the construction of a Base Station with multiple sectors (1, 2, 3 or more). Full Spectrum Confidential FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 An external bridge/router is used to forward/route the traffic to the appropriate sector. Note that the most common deployment is a 3 sector configuration. The sector configuration dictates the type of antenna that should be used. d) FullMAX supports various frequency reuse schemes as outlined in Annex A to this document. e) The FullMAX BS antenna is typically installed at an existing utility tower. The antenna should be installed as high on the tower as possible. The BS also employs a GPS antenna for TDD framing synchronization. f) The FullMAX FS4000 is used at a fixed location installed in a shelter at the remote site. The FullMAX MS4000 is typically installed inside the cabin of a vehicle. Both the FS4000 and the MS4000 supports Ethernet 100 Base T connectivity as well as serial RS232 connectivity. The serial connectivity is needed to support various legacy applications like Supervisory Control and Data Acquisition (SCADA) applications. 1.2 BS1000, FS4000 and MS4000 Hardware Architecture a) The FullMAX BS1000, FS4000 & MS4000 radio architecture is described in figure 2-1 and 2-2 below. It consists of a Baseband Processor Board (BBP), an Analog Front End (AFE) section and a Low Voltage Power Supply (LVPS) board. b) The BBP block diagram is described in figure 2-3. It is the heart of the FullMAX radio. It is designed to perform MAC, PHY, networking, network management and other functions that are required in a broadband wireless system. The BBP has the following main characteristics: 1) Processing resources: a. A TI DSP and a Xilinx Spartan 3A FPGA to execute the PHY layer b. A Freescale PQ3 processor to execute the MAC layer and complementary embedded software 2) A GPS time reference module is available for synchronization1 and for location based services. 3) User interfaces: 100 Base T, RS232 4) Interface to the AFE is done through a digital I/Q interface. c) The AFE section block diagram is described in figure 2-4. The AFE section performs signal processing functions that are needed to deliver the signal to the antenna and to receive the signal from the antenna. The AFE consists of: 1) A RF Small Signal (RFSS) board which contains a baseband section, an IF section and an RF section. e.g. for TDD frame synchronization. Full Spectrum Confidential FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 a. The baseband section consists of an A/D, D/A, a programmable receive baseband filter, a Digital Pre Distortion (DPD) Equalizer a programmable sampling clock synthesizer and a FPGA. b. The IF section consists of an IF LO, an I/Q modulator/demodulator, an IF receive channel bank and an IF transmit filter. c. The RF section consists of a RF LO, an RF up/down convertor, an RF receive channel bank and a RF transmit filter. 2) A RF Front End (RFFE) board which contains a RF PA, LNA, AGC and T/R switch. 3) The AFE employs three 8051 microcontrollers for monitoring and control of all aspects of the AFE operation. A serial interface protocol is available to support control of the master housekeeping microcontroller on the RFSS board by the main PQ3 processor on the BBP board. Note: The AFE employs a non-agile external RF bandpass filter which is shown as a yellow block in the AFE block diagram in figure 4. d) The Low Voltage Power Supply (LVPS) block diagram is described in figure 2-5. The LVPS generates all the voltages that are needed at the BBP and the AFE. It is designed for an input voltage range of 9 to 36 VDC to support power feed for a vehicle battery. An optional external power brick is available if needed to support AC or -48 VDC power feed. Figure 2-1: FullMAX BS1000, FS4000 & MS4000 High Level Architecture Full Spectrum Confidential FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 SDR BS/MS On-Off (For BS) I-2 Low Voltage Power Supply (LVPS) On-off switch (For BS) RFFE I-5 Power -on Indicator I-6 BIT Indicator I-7 SDR Wireless connectivity I-8 GPS Wireless connectivity SDR Antenna (For MS) Analog Front End (AFE) DC power UI I-1 Power Conn. Power LED BIT LED Power Connector 10/100 Ethernet I-3 RJ45 Ethernet connector AFE Connector RFSS GPS Antenna BBP Board GPS SMA RS232 COM port I-4 DB-9 Serial Connector Processor JTAG Test Connector DSP JTAG FPGA JTAG Figure 2-2: FullMAX BS1000, FS4000 & MS4000 Block Diagram Full Spectrum Confidential FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Power -LED POWER SUPPLY 3.3V 5V 32V 15V 5V 3.3V ENABLE 1.1V CPLD 3.3V 5V 1.1V ENABLE 1.1V ENABLE 2.5V ENABLE 1.8V ENABLE 1.24V MPC ENABLE 1.2V ENABLE 2.5V ENABLE 1.8V 2.5V 1.1V SENSOR ENABLE 1.24V 1.8V 2.5V SENSOR MPC ENABLE 1.2V 1.24V 1.8V SENSOR MPC I/O SUPPLY TMS I/O SUPPLY FPGA I/O SUPPLY 1.2V 1.24V SENSOR MPC TMS(DDR2) 1.2V SENSOR FPGA TMS MCX Conncector 2.54mm 10X2 DDR2 128MB DDR2 128MB DDR2 128MB Integrated Magnetic Vertical RJ45 Connector 125MHz 32MB 32MB DDR2 DDR2 GPS 25MHz 16X BUFFER 25MHz PROM MULTIPLIER 133MHz Flash1 64MB 0MARVEL MPC8548E SWITCH SGMII GPIO-1,2 TMS320TCI6482 32V 5V 15V 3.3V AFE FPGA XC3SD3400A EMIFA MUX I2C I2C I2C EEPROM RS232 Driver Serial Configuration UART 1 & 2 33.33MHz MPC JTAG TRANSLA TOR RJ45 CONNECTOR MPC TEMP SENSOR LED TMS JTAG XILINIX JTAG Flash1 64MB I/O - 16 DDR2 128MB LED LED Figure 2-3: Baseband Processor (BBP) Board Block Diagram Full Spectrum Confidential FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Figure 2- 4: Analog Front End (AFE) Block Diagram Full Spectrum Confidential FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 O/P connectors Low Voltage Power supply block diagram I_IN _1 Protection circuits U5 28V/5A LM5118 BuckBoost I_OUT_1 Reverse Polarity protection 9-36V DC Control I_IN _2 U3 5.15V/10A TPS40054 Buck I_OUT_2 To RFSS U9 15V @75mA LM78L15AC Fly back U15 5V@2A TPS75801 LDO U17 3.3V@1.5A EN5336Q Buck FUSE U1 Under/ Over Voltage monitor LT4356 ) U6 SMPS Controller (UC3843) To RFFE U8 32V@10mA LM317L Fly back (U8) FILTER Over current protection 28V/5A To RFSS To RFSS To RFSS I_IN U4 5V@3A TPS75801 LDO U16 3.3V@3A EN5364Q Buck To BBP To BBP Figure 2-5: Low Voltage Power Supply (LVPS) Block Diagram Full Spectrum Confidential 10 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 1.3 FullMAX BS1000, FS4000 and MS4000 Software Architecture a) The FullMAX BS1000, FS4000 and MS4000 software architecture is described in figure 2-6 below. It consists of PHY layer, MAC layer and general purpose embedded software components. Figure 2-6: FullMAX BS1000, FS4000 & MS4000 software architecture Full Spectrum Confidential 11 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 2 FullMAX BS1000, FS4000 and MS4000 Embedded Software Functionality a) The FullMAX BS1000, FS4000 and MS4000 support the MAC and PHY layer requirements as defined in the “WiMAX Forum Mobile System Profile Release 1.0 Approved Specifications”. This section describes the complementary embedded software that is not considered part of the MAC and the PHY layer software. b) Networking: o Supports communication over a 100 Base T Ethernet interface o Supports IP host functionality: the BS1000, FS4000 & MS4000 have an IP address and they support the following IP protocols: DHCP, ARP, ICMP, TFTP, FTP, SNMP, ToD (RFC-868). Also, the BS1000, FS4000 and MS4000 have a read only MAC address which is programmable during manufacturing. o Learning bridge and layer 2 forwarding: the BS1000, FS4000 and MS4000 support learning bridge functionality, maintain a Table of Connected Entities (TCE) and use it to forward packets to the correct destination (Ethernet interface, wireless interface or IP host) c) QOS: o Most of the QoS functionality is considered part of the MAC layer. The general purpose embedded software provides complimentary QoS functionality such as traffic prioritization. d) Security: o The general embedded software supports encryption and authentication functionality and processes which are complimentary to the MAC layer security functionality. e) Provisioning: o IP address provisioning (the BS1000, FS4000 and MS4000 acquire an IP address from an external standard DHCP server). o Time provisioning (the BS1000, FS4000 and MS4000 acquire date and time from an RFC-868 Time server). o EAP Provisioning (The BS1000, FS4000 and MS4000 acquire the MSK Key from the AAA server). o Configuration provisioning (the BS1000, FS4000 and MS4000 configuration provisioning is done through CLI and through SNMP commands). Full Spectrum Confidential 12 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 o QoS Provisioning (the BS1000, FS4000 and MS4000 QOS provisioning is done through SNMP commands). f) Channel Acquisition o The FS4000 and the MS4000 support a pre-configured channel acquisition plan, i.e., a preconfigured list of channel alternatives, characterized by their center frequency and the bandwidth. The radios go through the list and performs successive channel acquisition attempts until an attempt is successful. o Criteria for channel acquisition success: ■ Successful registration if the FS4000 and MS4000 were not registered prior to channel acquisition. ■ Successful ranging if the FS4000 and MS4000 were registered prior to channel acquisition (i.e., in the case of moving to a new BS1000). o Once a channel is successfully acquired, the parameters of the acquired channel are saved to the radio’s flash memory and are used as the first acquisition option when powering on. g) Network Management Support o The BS1000, FS4000 and MS4000 have a SNMPv2c agent and can be remotely managed by the FullMAX Network Management System outlined in Paragraph 4 below. o The BS1000, FS4000 and MS4000 also support a Telnet based Command Line Interface (CLI) protocol which can be used to configure all radio BS1000, FS4000 and MS4000 parameters. h) Miscellaneous BS1000, FS4000 and MS4000 hardware platform Management o Remote and secure software download o Initialization and configuration Persistence: The BS1000, FS4000 and MS4000 support a CLI command that initiates the saving of the configuration in the flash. Saved configuration is used after power off. Full Spectrum Confidential 13 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 3 FullMAX System Installation and Commissioning 3.1 Enclosure of BS1000, FS4000 and MS4000 The BS1000, FS4000 and MS4000 devices share the same enclosures Figure 1: Top View Figure 2: Bottom View (with FCC label) Figure 3: Front View Figure 4: Rear View Figure 5: Right Side View Figure 6: Left Side View 3.2 Connecting the BS1000, FS4000 and MS4000 1. Place the enclosure in a stable location. Make sure that air can run freely to the fans on the rear of the enclosure and the holes on the enclosures sides. 2. Connect the cable from the Antenna to the device RF connector on the enclosure left side. Full Spectrum Confidential 14 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 3. Use an Ethernet cable to connect the device with end equipment 4. Connect the power cable to the power connector on the enclosure left side. 5. Connect the power label to the power source. 3.3 FullMAX BS1000, FS4000 & MS4000 Tune Up and Alignment Procedures 1. Frequency and transmit power configuration of the FullMAX BS1000, FS4000 and MS4000 is done by means of either a Command Line Interface (CLI) tool or a Web based Network Management (NMS) tool. 2. The NMS/CLI tools is used to configure the following parameters: a. BS1000, FS4000, MS4000 parameters: i. Center RF frequency ii. Channel bandwidth iii. Transmit power b. FS4000 and MS4000 parameters: i. Maximum uplink transmit power ii. An automatic channel acquisition table with up to 10 entries. Each entry includes the center frequency and the channel bandwidth. 3. The center frequency, channel bandwidth and transmit power at the BS1000, FS4000 and MS4000 are configured statically by the NMS/CLI tool. This means that the values will be maintained unless they are changed by the CLI/NMS tool. 4. The FS4000 and MS4000 on the other hand, perform automatic channel acquisition by selecting dynamically, the best channel (highest RSSI) from a list of up to 10 pre-configured entries (see paragraph 2bi above). The transmit power of the FS and MS are controlled by an automatic closed loop power control algorithm running at the BS1000. The transmit power of the FS and MS are increased by the BS1000 as the distance to the FS and MS are increased (i.e., as the path loss increases and the RSSI as measured by the BS1000 becomes lower). Note however that the FS and MS will not transmit above the maximum uplink transmit power (see paragraph 2bii) even if ordered by the BS1000. 5. The BS, FS and MS employ an external RF bandpass filter as described in Annex A to this document. This is an additional safeguard which Full Spectrum Confidential 15 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 guarantees that the BS1000, FS4000 and the MS4000 will not transmit outside the band. 6. The remainder of the document describes the CLI commands that are used to configure the BS1000, FS4000 and MS4000 parameters described above. 3.4 CLI Commands for BS1000, FS4000, MS4000 After logging in through telnet [FULLMAX]$ Prompt for user is displayed. Type help or ? to look at different groups. Lock to dl-config group using dl-config command [FULLMAX]$ [FULLMAX]$ dl-config You are locked to dl-config group. Only dl-config operations are allowed. Use help or ? for help. [FULLMAX(dl-config)]$ For Frequency: [FULLMAX(dl-config)]$ show center-freq center-freq 940500 khz [FULLMAX(dl-config)]$ set center-freq updated center-freq 930800 khz For Tx Power : [FULLMAX(dl-config)]$ show tx_power tx_power 9 dbm [FULLMAX(dl-config)]$ set tx_power 16 updated tx_power 16 dbm For Channel Bandwidth: [FULLMAX(dl-config)]$ show bandwidth Full Spectrum Confidential 16 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 bandwidth 500 khz For FFT-Size: [FULLMAX(dl-config)]$ show fft_size fft_size 128fft 3.5 Monitoring the BS / FS/ MS with the FullMAX NMS For monitoring the BS availability and performance it should be added to the NMS. Login to the NMS as an 'Admin'. If the BS1000 is located in a new tower: On NMS menu select: Admin New BS Tower Type in tower name Click 'Save' On NMS menu select: Admin New BS Sector Type in a 'sector name' Select the tower on which the sector is installed Add the BS1000 IP address Click 'Save' The BS1000 availability and performance will now be monitored by the NMS. Full Spectrum Confidential 17 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 4 FullMAX system operation 4.1 Operation Restrictions / Information to User a) Changes or modifications not expressly approved by Full Spectrum Inc. could void the user’s authority to operate the equipment. b) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: b.1.1.1 Reorient or relocate the receiving antenna. b.1.1.2 Increase the separation between the equipment and receiver. b.1.1.3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. b.1.1.4 Consult the dealer or an experienced radio/TV technician for help 4.2 BS1000 Operation The FullMAX BS CLI supports the following commands. The access to this commands are based on the user privileges. The Admin has the privilege to control and monitor all the information supported by the FullMAX BS CLI commands, whereas the operator has limited privileges. After the successful authentication, the user is permitted access to the command line interface. Based on the user privileges, the help menu will be displayed to the user. 4.2.1 Main Group When the user logs in to the CLI it will lock to the default group which is the main group. Whenever the user enters the Main group, the CLI will display the main prompt. The Help command in main group will show the commands supported in main group along with the group lock commands. Only commands related to main group can be executed in main group. FullMAX# System IP address. Full Spectrum Confidential 18 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Command FullMAX# set ip-addressFullMAX# show ipaddress Purpose Updates the system IP address. Displays the system IP address. Privileges A/O A/O Example: FullMAX#set ip-address 10.60.4.42 Updated IP address: 10.60.4.42 FullMAX# show ip-address IP address: 10.60.4.56 DHCP server IP address. Command Purpose FullMAX#set dhcp-config- Allows the user to update the BS with the DHCP server IP server-ip address. Allows the user to display the FullMAX# show dhcpremote DHCP server IP config-server-ip address Privileges A/O A/O Example: FullMAX# set dhcp-config-server-ip 10.60.1.11 Updated DHCP server IP 10.60.1.11 FullMAX# show dhcp-config-server-ip DHCP server IP 0.0.0.0 DHCP remote ID. Command FullMAX# set dhcpconfig-remote-id FullMAX# show dhcpconfig-remote-id Purpose Allows the user to update the DHCP remote ID Privileges A/O Allows the user to displays the A/O DHCP remote ID Example: FullMAX# set dhcp-config-remote-id 0019D1:50CC62 Full Spectrum Confidential 19 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Updated dhcp-config-remote-id 0019D1:50CC62 FullMAX# show dhcp-config-remote-id dhcp-config-remote-id 0019D1:50CC62 DHCP circuit ID Command FullMAX# set dhcpconfig-circuit-id FullMAX# show dhcpconfig-circuit-id Purpose Allows the user to updates the DHCP circuit ID Allows the user to display the DHCP circuit ID Privileges A/O A/O Example: FullMAX# set dhcp-config-circuit-id 3 Updated dhcp-config-circuit-id 3 FullMAX# show dhcp-config-circuit-id dhcp-config-circuit-id 0 4.2.2 mac-config mac-config group defines the commands that monitors or updates the MAC configuration information. The user upon entering the mac-config command , locks into this particular group to execute commands only related to the BS configuration. FullMAX# FullMAX# mac-config FullMAX(mac-config)# Command Purpose Privileges FullMAX# macconfig The command allows the user to lock into the group mac-config and execute all the commands related to the group. A/O The commands supported by the mac-config group are The command describes the time between transmissions of DCD messages in milliseconds. Full Spectrum Confidential 20 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Command FullMAX(mac-config)# set dcd-interval FullMAX(mac-config)#show dcd-interval Purpose Privileges The command allows the user to update the transmission time between to DCD messages. The command allows the user to find A/O the time interval for transmission of consecutive DCD messages. Example: FullMAX(mac-config)# set dcd-interval 30 Updated dcd-interval 30 milliseconds FullMAX(mac-config)# show dcd-interval dcd-interval 30 milliseconds The command describes the time between transmissions of UCD messages in milliseconds. Command FullMAX(mac-config)# set ucd-interval FullMAX(mac-config)# show ucd-interval Purpose The command allows the user to update the transmission time between to UCD messages. The command allows the user to find the time interval for transmission of consecutive UCD messages. Privileges A/O Example: FullMAX(mac-config)# set ucd-interval 30 Updated ucd-interval 30 milliseconds FullMAX(mac-config)# show ucd-interval ucd-interval 30 milliseconds The number of frames from the end of the frame carrying the DCD message the BS shall wait after transmitting a DCD message with an incremented Configuration Change count before issuing a DL-MAP message referring to Downlink Burst profiles defined in that DCD message. Command FullMAX(mac-config)# set dcd-transition Purpose Privileges This command allows the user to change A the configuration count, the BS shall wait to transmit DL-MAP after transmitting the DCD message. Full Spectrum Confidential 21 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(mac-config)#show dcd-transition The command allows the user to find the A/O configuration count, the BS shall wait (no. of frames) to transmit DL-MAP after transmitting the DCD message. Example: FullMAX(mac-config)# set dcd-transition 30 Updated dcd-transition 30 (MAC Frames) FullMAX(mac-config)# show dcd-transition dcd-transition 30 (MAC Frames) The number of frames from the end of the frame carrying the UCD message the BS shall wait after transmitting a UCD message with an incremented Configuration Change count before issuing a UL-MAP message referring to Uplink Burst profiles defined in that UCD message. Command FullMAX(mac-config)# set ucd-transition FullMAX(mac-config)#show ucd-transition Purpose This command allows the user to change the configuration count, the BS shall wait to transmit UL-MAP after transmitting the UCD message. The command allows the user to find the configuration count, the BS shall wait (no. of frames) to transmit UL-MAP after transmitting the UCD message. Privileges A/O Example: FullMAX(mac-config)# set ucd-transition 30 Updated ucd-transition 30 (MAC Frames) FullMAX(mac-config)# show ucd-transition ucd-transition 30 (MAC Frames) Number of Timeout Retries on DSA/DSC/DSD Responses. Command FullMAX(mac-config)# set dsx-rsp-retries FullMAX(mac-config)# show dsx-rsp-retries Purpose The command updates the value of the DSA/DSC/DSD responses retries timeout. The command displays the DSA/DSC/DSD responses retries timeout. Privileges A/O Example: Full Spectrum Confidential 22 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(mac-config)#set dsx-rsp-retries 6 Updated dsx-rsp-retries 6. FullMAX(mac-config)#show dsx-rsp-retries dsx-rsp-retries 3 Number of Timeout Retries on DSA/DSC/DSD Requests. Command Purpose Privileges FullMAX(mac-config)# set dsx-req-retries FullMAX(mac-config)#show dsx-req-retries The command updates the value of the DSA/DSC/DSD requests retries timeout. The command displays the DSA/DSC/DSD requests retries timeout. A/O Example: FullMAX(mac-config)#set dsx-req-retries 6000 Updated dsx-req-retries 6000 milliseconds. FullMAX(mac-config)#show dsx-req-retries dsx-req-retries 3. Wait for DSA/DSC/DSD Response Timeout in ms. Command FullMAX (mac-config) # set t7-timeout FullMAX (mac-config) # show t7-timeout Purpose The command updates the value of T7 timer, with in which the BS/SS should wait for a DSx response. The command displays the T7 timer, configured to which the BS/SS should wait for a DSx response. Privileges A/O Example: FullMAX(mac-config)#set t7-timeout 300 Updated t7-timeout 300 milliseconds. FullMAX(mac-config)# show t7-timeout t7-timeout 300 milliseconds. Wait for DSA/DSC/DSD Acknowledge Timeout in ms. Command Purpose Full Spectrum Confidential Privileges 23 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(mac-config)# set t8-timeout FullMAX(mac-config)# show t8-timeout The command updates the value of T8 timer, with in which the BS/SS should wait for a DSx acknowledge. The command displays the T8 timer, configured to which the BS/SS should wait for a DSx acknowledge. A/O Example: FullMAX(mac-config)# set t8-timeout 100 Updated t8-timeout 100 milliseconds. FullMAX(mac-config)# show t8-timeout t8-timeout 100 milliseconds. The time allowed between the BS sending a RNG-RSP to an SS, and receiving an SBCREQ from that same SS. Command FullMAX(mac-config)# set t9-timeout FullMAX(mac-config)#show t9-timeout Purpose The command updates the T9 timer value that waits for an SBC-REQ from an MS to which it has sent a RNG-RSP. The command displays the T9 Timer value configured in BS to wait for SBC-REQ from an MS to which the BS has sent the RNG-RSP. Privileges A/O Example: FullMAX(mac-config)#set t9-timeout 3200 Updated t9-timeout 3200 milliseconds FullMAX(mac-config)#show t9-timeout t9-timeout 3200 milliseconds The maximum time allowed to wait for a dynamic service transaction to end. Command FullMAX(mac-config)#set t10-timeout FullMAX(mac-config)#show t10-timeout Purpose The command updates the T10 timer value that waits for a dynamic service transaction end. The command displays the T10 timer value that waits for a dynamic service Full Spectrum Confidential Privileges A/O 24 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 transaction end. Example: FullMAX(mac-config)# set t10-timeout 1000 Updated t10-timeout 1000milliseconds FullMAX(mac-config)# show t10-timeout T10-timeout 1000milliseconds Time allowed for an SS, following the receipt of a REG-RSP message to send a TFTPCPLT message to the BS. Command FullMAX(mac-config)#set t13-timeout FullMAX(mac-config)#show t13-timeout Purpose The command updates the T13 timer for which the BS waits to receive TFTP-CPLT message after sending the REG-RSP. The command displays the T13 timer configured at BS to wait for TFTP-CPLT message after sending the REG-RSP Privileges A/O Example: FullMAX(mac-config)# set t13-timeout 13000 Updated t13-timeout 13000 milliseconds FullMAX(mac-config)# show t13-timeout t13-timeout 13000 milliseconds Time allowed for SS to complete authorization and key exchange. Command FullMAX(mac-config)#set t17-timeout FullMAX(mac-config)#show t17-timeout Purpose Privileges The command updates the value of T17 timer, with in which the SS should complete the authorization and key exchange. The command displays the T17 timer, A/O configured to which the SS should complete the authorization and key exchange. Example: FullMAX(mac-config)#set t17-timeout 6000 Updated t17-timeout 6000 milliseconds. FullMAX(mac-config)#show t17-timeout t17-timeout 6000 milliseconds. Full Spectrum Confidential 25 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Time to wait for an ARQ-reset. Command FullMAX(mac-config)# set t22-timeout FullMAX(mac-config)# show t22-timeout Purpose The command updates the T22 timer for which the BS waits for ARQ reset. The command displays the T22 timer configured at BS to wait for ARQ reset. Privileges A/O Example: FullMAX(mac-config)# set t22-timeout 200 Updated t22-timeout 200 milliseconds FullMAX(mac-config)# show t22-timeout t22-timeout 200 milliseconds The command defines weather BS is allowed to autonomously allocate SFIDs. If the BS is enabled with this feature, the BS can autonomously allocate SFIDs in configured SFID range. An SF is autonomously when it is not provisioned and may be initiated either by either BS or SS. Command FullMAX(mac-config)# set auto-sfid-enabled {enable | disable } FullMAX(mac-config)# show auto-sfid-enabled {enable | disable } Purpose This command allows the user to configure BS by allowing the BS to autonomously allocate SFIDs. Privileges This command displays the user, weather the BS is enabled/disabled to allocate SFIDs. A/ Example: FullMAX(mac-config)# set auto-sfid-enabled ENABLE Updated auto-sfid-enabled ENABLED FullMAX(mac-config)# show auto-sfid-enabled auto-sfid-enabled ENABLED The command defines the minimum value of the SFID for the range allocated to support the creation of service flows autonomously. Command FullMAX(mac-config)# set min-auto-sfid-range Purpose This command allows the user to define the minimum value of SFID to define the range in which the BS can autonomously Full Spectrum Confidential Privileges 26 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(mac-config)#show min-auto-sfid-range create Service flows. The command displays the user, the minimum value of sfid from which the BS can create service flows autonomously. A/O Example: FullMAX(mac-config)# set min-auto-sfid-range 6200 Updated min-auto-sfid-range 6200 FullMAX(mac-config)# show min-auto-sfid-range Updated min-auto-sfid-range 6200 The command defines the maximum value of the SFID for the range allocated to support the creation of service flows autonomously. Command FullMAX(mac-config)# set max-auto-sfid-range FullMAX(mac-config)# show max-auto-sfid-range Purpose This command allows the user to define the maximum value of SFID range in which the BS can autonomously create Service flows. The command displays the user, the maximum value of sfid upto which the BS can create service flows autonomously. Privileges A/O Example: FullMAX(mac-config)# set max-auto-sfid-range 6300 Updated max-auto-sfid-range 6300 FullMAX(mac-config)# show max-auto-sfid-range max-auto-sfid-range 6300 This command displays all the parametrs values for the mac-config group in CLI. Command FullMAX(mac-config)#show all Purpose The command displays the user, the value of all the mib parameters of tables in the group. Privileges A/O Example: FullMAX(mac-config)# show all dcd-interval 5000 milliseconds ucd-interval 5000 milliseconds ucd-transition 0 (MAC Frames) Full Spectrum Confidential 27 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 dcd-transition 0 (MAC Frames) t9-timeout 8000 milliseconds t13-timeout 0 milliseconds t15-timer 0 milliseconds t17-timeout 0 milliseconds auto-sfid-enabled DISABLE min-auto-sfid-range 0 max-auto-sfid-range 0 dsx-req-retries 3 dsx-rsp-retries 3 T7-timer 1000 milliseconds t8-timer 300 milliseconds t10-timer 3000 milliseconds t22-timer 200 milliseconds 4.2.3 ul-config The group defines the commands that monitors or updates the UCD channel attributes that define the characteristics of uplink channels. The user upon entering the ul-config command locks into the CLI to execute commands only related to BS uplink channel characteristics. FullMAX# FullMAX# ul-config FullMAX(ul-config)# Command FullMAX# ul-config Purpose The command allows the user to lock into the group ul-config and execute all the commands related to the group. The number of UL-MAPs to receive before contention-based reservation is attempted again for the same connection. Command FullMAX(ul-config)# set ct-based-reserve-timeout FullMAX(ul-config)#show ct-based-reserve-timeout Purpose The command allows the user to update number of UL-MAPs to receive before contention-based reservation is attempted again for the same connection. The command allows the user to display number of UL-MAPs to receive before contention-based reservation is attempted again for the same connection. Privileges A/O Example: Full Spectrum Confidential 28 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(ul-config)# set ct-based-reserve-timeout 30 Updated ct-based-reserve-timeout 30 FullMAX(ul-config)# show ct-based-reserve-timeout ct-based-reserve-timeout 30 Uplink center frequency (in KHz). Command FullMAX(ul-config)#set uplink-center-frequecy FullMAX(ul-config)#show uplink-center-frequecy Purpose The command allows the user to update the uplink center frequency. The command allows the user to display the uplink center frequency. Privileges A/O Example: FullMAX (ul-config) # set uplink-center-frequency 30 updated uplink-center-frequecy 30 KHz FullMAX (ul-config) # show uplink-center-frequency uplink-center-frequecy 30 KHz Number of initial ranging CDMA codes. Command FullMAX(ul-config)# set init-rng-codes FullMAX(ul-config)#show init-rng-codes Purpose The command allows the user to update the Number of initial ranging CDMA codes. The command allows the user to display the number of initial ranging CDMA codes. Privileges A/O Example: FullMAX(ul-config)# set init-rng-codes 10 Updated init-rng-codes 10 FullMAX(ul-config)# show init-rng-codes init-rng-codes 10 Number of periodic ranging CDMA codes. Command FullMAX(ul-config)# set periodic-rng-codes Purpose The command allows the user to update the Number of periodic ranging CDMA Full Spectrum Confidential Privileges 29 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(ul-config)#show periodic-rng-codes codes. The command allows the user to display the number of periodic ranging CDMA codes. A/O Example: FullMAX(ul-config)# set periodic-rng-codes 20 Updated periodic-rng-codes 20 FullMAX(ul-config)# show periodic-rng-codes periodic-rng-codes 20 Number of bandwidth request codes. Command FullMAX(ul-config)#set bandwidth-requestcodes FullMAX(ul-config)#show bandwidth-request-codes Purpose The command allows the user to update the number of bandwidth request codes. Privileges The command allows the user to display the number of bandwidth request codes. A/O Example: FullMAX(ul-config)#set bandwidth-request-codes 20 Updated bandwidth-request-codes 20 FullMAX(ul-config)#show bandwidth-request-codes bandwidth-request-codes 20 Initial backoff window size for periodic ranging contention expressed as a power of 2 Command FullMAX(ul-config)#set per-rng-backoff-start FullMAX(ul-config)#show per-rng-backoff-start Purpose The command allows the user to update the initial backoff window size for periodic ranging contention. The command allows the user to display the initial backoff window size for periodic ranging contention. Privileges A/O Example: FullMAX (ul-config) # set per-rng-backoff-start 4 Updated per-rng-backoff-start 4 Full Spectrum Confidential 30 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX (ul-config) # show per-rng-backoff-start per-rng-backoff-start 4 Final backoff window size for periodic ranging contention, expressed as a power of 2 Command FullMAX(ul-config)# set per-rng-backoff-end FullMAX(ul-config)# show per-rng-backoff-end Purpose The command allows the user to update the final backoff window size for periodic ranging contention. The command allows the user to display the final backoff window size for periodic ranging contention. Privileges A/O Example: FullMAX(ul-config)# set per-rng-backoff-end 8 Updated per-rng-backoff-end 8 FullMAX(ul-config)# show per-rng-backoff-end per-rng-backoff-end 8 Indicates the starting number, of the group of codes used for uplink Command FullMAX(ul-config)#set start-off-rng-codes FullMAX(ul-config)#show start-off-rng-codes Purpose The command allows the user to update the starting number of the codes used for uplink The command allows the user to display the starting number of the codes used for uplink. Privileges A/O Example: FullMAX(ul-config)# set start-off-rng-codes 64 Updated start-off-rng-codes 64 FullMAX(ul-config)# show start-off-rng-codes start-off-rng-codes 64 Determines the UL_PermBase parameter for the sub carrier permutation to be used on this uplink channel. Full Spectrum Confidential 31 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Command FullMAX(ul-config)# set permutation-base FullMAX(ul-config)# show permuation-base Purpose The command allows the user to updates the UL_PermBase parameter for the sub carrier permutation to be used on this uplink channel. The command allows the user to display the UL_PermBase parameter for the sub carrier permutation to be used on this uplink channel. Privileges A/O Example: FullMAX(ul-config)# set permutation-base 127 Updated permutation-base 127 FullMAX(ul-config)#show permutation-base permutation-base 8 This is a bitmap describing the physical sub-channels allocated to the segment in the UL, when using the uplink PUSC permutation. The LSB of the first byte shall correspond to subchannel 0. Command FullMAX(ul-config)# set ul-alloc-sub-channelbitmap FullMAX(ul-config)#show ul-alloc-sub-channelbitmap Purpose The command allows the used to update the ofdma subchannel allocation. Privileges The command allows the user to display the ofdma subchannel allocation. A/O Example: FullMAX(ul-config)#set ul-alloc-sub-channel-bitmap 00110001 Updated ul-alloc-sub-channel-bitmap ff FullMAX(ul-config)# show ul-alloc-sub-channel-bitmap ul-alloc-sub-channel-bitmap 00110001 Threshold of the maximum of the standard deviations of the individual bands CINR measurements over time to trigger mode transition from normal sub channel to Band AMC. Command Purpose Full Spectrum Confidential Privileges 32 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(ul-config)# set band-amc-alloc-threshold FullMAX(ul-config)#show band-amc-alloc-threshold The command allows the user to update A the parameter for AMC band allocation Threshold. The command allows the user to display the parameter for AMC band allocation threshold. A/O Example: FullMAX(ul-config)# set band-amc-alloc-threshold 64 Updated band-amc-alloc-threshold 64 dB FullMAX(ul-config)# show band-amc-alloc-threshold band-amc-alloc-threshold 64 dB Threshold of the maximum of the standard deviations of the individual bands CINR measurements over time to trigger mode transition from Band AMC to normal subchannel. Command FullMAX(ul-config)# set band-amc-release-threshold FullMAX(ul-config)#show band-amc-release-threshold Purpose The command allows the user to update the parameter that defines the maximum threshold for AMC band. The command allows the user to display the parameter that defines the maximum threshold for AMC band. Privileges A/O Example: FullMAX(ul-config)# set band-amc-release-threshold 56 Updated band-amc-release-threshold 56 dB FullMAX(ul-config)# show band-amc-release-threshold band-amc-release-threshold 56 dB Minimum required number of frames to measure the average and standard deviation for the event of Band AMC triggering. Command Purpose FullMAX(ul-config)# set band-amc-alloc-timer The command allows the user to update the parameter that defines the minimum Full Spectrum Confidential Privilege 33 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(ul-config)#show band-amc-alloc-timer required number of frames to measure the average and standard deviation for the event of Band AMC triggering. The command allows the user to display parameter that defines the minimum required number of frames to measure the average and standard deviation for the event of Band AMC triggering. A/O Example: FullMAX(ul-config)# set band-amc-alloc-timer 22 Updated band-amc-alloc-timer 22 Frames FullMAX(ul-config)# show band-amc-alloc-timer band-amc-alloc-timer 22 Frames Minimum required number of frames to measure the average and standard deviation for the event of Band AMC triggering. Command FullMAX(ul-config)# set band-amc-release-timer FullMAX(ul-config)#show band-amc-release-timer Purpose The command allows the user to update the parameter that defines the minimum required number of frames to measure the average and standard deviation for the event of Band AMC triggering. The command allows the user to display parameter that defines the minimum required number of frames to measure the average and standard deviation for the event of Band AMC triggering. Privileges A/O Example: FullMAX(ul-config)#set band-amc-release-timer 22 Updated band-amc-release-timer 22 Frames FullMAX(ul-config)#show band-amc-release-timer band-amc-release-timer 22 Frames Backoff timer between consecutive mode transitions from normal subchannel to Band AMC when the previous request is failed. Command FullMAX(ul-config)#set band-amc-retry-timer Purpose The command allows the user to update the parameter band AMC retry Full Spectrum Confidential Privileges 34 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(ul-config)#show band-amc-retry-timer timer The command allows the user to display parameter band AMC retry timer. A/O Example: FullMAX(ul-config)# set band-amc-retry-timer 5 Updated band-amc-retry-timer 5 FullMAX(ul-config)# show band-amc-retry-timer band-amc-retry-timer 5 Maximum period between refreshing the Band CINR measurement by the unsolicited REP-RSP. Command FullMAX(ul-config)# set band-stat-rep-max-period FullMAX(ul-config)# show band-stat-rep-max-period Purpose The command allows the user to update the maximum period between refreshing the Band CINR measurement by the unsolicited REP-RSP. The command allows the user to display the maximum period between refreshing the Band CINR measurement by the unsolicited REP-RSP. Privileges A/O Example: FullMAX(ul-config)# set band-stat-rep-max-period 12 Updated band-stat-rep-max-period 12 FullMAX(ul-config)# show band-stat-rep-max-period band-stat-rep-max-period 12 MS specific up power offset adjustment step. Command FullMAX(ul-config)#set band-stat-rep-max-period FullMAX(ul-config)#show band-stat-rep-max-period Purpose The command allows the user to update the maximum period between refreshing the Band CINR measurement by the unsolicited REP-RSP. The command allows the user to display the maximum period between refreshing the Band CINR measurement by the unsolicited REP-RSP. Privileges A/O Example: Full Spectrum Confidential 35 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(ul-config)# set up-power-adj-step 12 Updated up-power-adj-step 12 (in 0.01 dB). FullMAX(ul-config)# show up-power-adj-step up-power-adj-step 12 (in 0.01 dB). MS specific down power offset adjumstment step. Command FullMAX(ul-config)# set down-power-offset-adj-step FullMAX ul-config)# show down-power-offset-adj-step Purpose The command allows the user to update the MS specific down power offset adjustment step. Privileges The command allows the user to display the MS specific down power offset adjustment step. A/O Example: FullMAX(ul-config)# set down-power-offset-adj-step 6 Updated down-power-offset-adj-step 6 (in 0.01 dB). FullMAX(ul-config)# show up-power-offset-adj-step up-power-offset-adj-step 6 (in 0.01 dB). Minimum level of power offset adjustment. Command FullMAX(ul-config)# set min-power-offset-adj Purpose The command allows the user to update the value of Minimum level of power offset adjustment. The command allows the user to display the value of Minimum level of power offset adjustment. FullMAX(ul-config)#show min-power-offset-adj Privileges A/O Example: FullMAX(ul-config)# set min-power-offset-adj 2 Updated min-power-offset-adj 2 (in 0.01 dB). FullMAX(ul-config)# show min-power-offset-adj min-power-offset-adj 2 (in 0.01 dB). Maximum level of power offset adjustment. Command Purpose Full Spectrum Confidential Privileges 36 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(ul-config)#set max-power-offset-adj FullMAX(ul-config)#show max-power-offset-adj The command allows the user to update the value of maximum level of power offset adjustment. The command allows the user to display the value of maximum level of power offset adjustment. A/O Example: FullMAX (ul-config) # set max-power-offset-adj 16 Updated max-power-offset-adj 16 (in 0.01 dB). FullMAX (ul-config) # show max-power-offset-adj max-power-offset-adj 16 (in 0.01 dB). Initial backoff window size for initial ranging connection, expressed as a power of 2. Command FullMAX(ul-config)# set intial-rng-backoff-start FullMAX(ul-config)#show intial-rng-backoff-start Purpose The command allows the user to update the value of initial backoff window size for initial ranging connection. Privileges The command allows the user to display the value of initial backoff window size for initial ranging connection. A/O Example: FullMAX(ul-config)# set intial-rng-backoff-start 2 Updated intial-rng-backoff-start 2 FullMAX(ul-config)# show intial-rng-backoff-start intial-rng-backoff-start 2 Final backoff window size for initial ranging connection, expressed as a power of 2. Command FullMAX(ul-config)# set intial-rng-backoff-end FullMAX(ul-config)# show intial-rng-backoff-end Purpose The command allows the user to update the value of final backoff window size for initial ranging connection. Privileges The command allows the user to display the value of final backoff window size for initial ranging connection. A/O Example: Full Spectrum Confidential 37 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(ul-config)# set intial-rng-backoff-end 8 Updated intial-rng-backoff-end 8 FullMAX(ul-config)# show intial-rng-backoff-end intial-rng-backoff-end 8 Initial backoff window size for contention bandwidth requests, expressed as a power of 2. Command FullMAX(ul-config)# set bw-req-backoff-start FullMAX(ul-config)#show bw-req-backoff-start Purpose The command allows the user to update the value of initial backoff window size for contention bandwidth requests. The command allows the user to display the value of initial backoff window size for contention bandwidth requests. Privileges A/O Example: FullMAX(ul-config)#set bw-req-backoff-start 4 Updated bw-req-backoff-start 4 FullMAX(ul-config)#show bw-req-backoff-start bw-req-backoff-start 4 Final backoff window size for contention bandwidth requests, expressed as a power of 2. Command FullMAX(ul-config)# set bw-req-backoff-end FullMAX(ul-config)# show bw-req-backoff-end Purpose The command allows the user to update the value of final backoff window size for contention bandwidth requests. The command allows the user to display the value of final backoff window size for contention bandwidth requests. Privileges A/O Example: FullMAX(ul-config)# set bw-req-backoff-end 8 Updated bw-req-backoff-end 4 FullMAX(ul-config)# show bw-req-backoff-end bw-req-backoff-end 4 Full Spectrum Confidential 38 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 This command displays all the parameter values of tables supported in this group. Command FullMAX(ul-config)# show all Purpose The command allows the user to display the value of all the MIB parameters of tables supported in this group. Privileges A/O Example: FullMAX(ul-config)# show all ct-based-reserve-timeout 200 uplink-center-frequency 200 init-rng-codes 0 periodic-rng-codes 50 bandwidth-request-codes 0 per-rng-backoff-start 20 permutation-base 0 ul-alloc-sub-channel-bitmap 3 band-amc-alloc-threshold 60 db band-amc-release-threshold 0 db band-amc-alloc-timer 255 Frames band-amc-release-timer 0 Frames 4.2.4 dl-config The group defines the commands that monitors or updates the DCD channel attributes that define the characteristics of downlink channel. The user upon entering the dl-config command locks into the CLI to execute commands only related to BS downlink channel characteristics. FullMAX# FullMAX# dl-config FullMAX(dl-config)# Command FullMAX# dl-config Purpose Privileges The command allows the user to lock A/O into the group dl-config and execute all the commands related to the group. This command Displays the values of all the commands affiliated to dl-channel-table in the dl-config group. Command FullMAX(dl-config)#show dl-channel-table Purpose The command allows the user to display the DL Channel table MIB parameter values. Full Spectrum Confidential Privileges A/O 39 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Example: FullMAX(dl-config)# show dl-channel-table bs-eirp 244 dBm downlink-center-frequency 244 khz bsid 00f401:0000f4 hysterisis-margin 45 dB time-to-trigger 2 milliseconds The duration of the frame Command FullMAX(dl-config)#set frame-duration-code FullMAX(dl-config)#show frame-duration-code Purpose The command allows the user to update the OFDMA frame duration code. The command allows the user to display the OFDMA frame duration code. Privileges A/O Example: FullMAX(dl-config)# set frame-duration-code 12 updated frame-duration-code 12 FullMAX(dl-config)# show frame-duration-code frame-duration-code 12 The EIRP is the equivalent isotropic radiated power of the base station, which computed for a simple single-antenna transmitter. Command FullMAX(dl-config)#set bs-eirp FullMAX(dl-config)#show bs-eirp Purpose The command allows the user to update the BS EIRP parameter Privileges The command allows the user to display the BS EIRP parameter A/O Example: FullMAX(dl-config)# set bs-eirp 3770 Updated bs-eirp 3770 dBm FullMAX(dl-config)# show bs-eirp bs-eirp 3770 dBm Downlink center frequency (Khz). Full Spectrum Confidential 40 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Command FullMAX(dl-config)# set downlink-center-frequency FullMAX(dl-config)#show downlink-center-frequency Purpose Privileges The command allows the user to update the A downlink center frequency. The command allows the user to display the downlink center frequency. A/O Example: FullMAX (dl-config)# set downlink-center-frequency 11000 Updated downlink-center-frequency 11000 kHz FullMAX(dl-config)# show downlink-center-frequency downlink-center-frequency 11000 kHz. Defines the encoding of BSID. The BSID is a 6 byte number and follows the encoding rules of MacAddress textual convention, e.e as if it were transmitted least-significant bit first. The value should be displayed with 2 parts clearly separated by a colon e.g : 001DFF:00003A. The most significant part is representing the operator ID. Command FullMAX(dl-config)# set bsid FullMAX(dl-config)#show bsid Purpose The command allows the user to update the BS ID Privileges The command allows the user to display the BS ID A/O Example: FullMAX(dl-config)# set bsid 0A30A1:10FE11 Updated bsid 0A30A1:10FE11 FullMAX(dl-config)# show bsid bsid 0A30A1:10FE11 Channel Bandwidth in Khz Command FullMAX(dl-config)# set bandwidth FullMAX(dl-config)#show Purpose Privileges The command allows the user to updates the A channel bandwidth. The command allows the user to display the Full Spectrum Confidential A/O 41 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 channel bandwidh. bandwidth Example: FullMAX(dl-config)# set bandwidth 400 Updated bandwidth 400 KHz FullMAX(dl-config)# show bandwidth bandwidth 400 KHz Sampling clock for the channel Command FullMAX(dl-config)#set sampling-clock FullMAX(dl-config)#show sampling-clock Purpose The command allows the user to updates the sampling clock. Privileges The command allows the user to display the sampling clock. A/O Example: FullMAX(dl-config)# set sampling-clock 12800 Updated sampling-clock 12800 KHz FullMAX(dl-config)# show sampling-clock sampling-clock 12800 KHz The ID of the PHY filter to use for this channel Command FullMAX(dl-config)# set filter-id Purpose The command allows the user to updates the filter id. Privileges FullMAX(dl-config)#show filter-id The command allows the user to display the filter id. A./O Example: FullMAX(dl-config)# set filter-id 1 Updated filter-id 1 FullMAX(dl-config)# show filter-id filter-id 1 ︳ FFT size for OFDMA PHY Command Purpose Full Spectrum Confidential Privileges 42 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(dl-config)# set fft_size FullMAX(dl-config)#show fft_size The command allows the user to updates the fft_size. The command allows the user to display the fft_size A/O Example: FullMAX (dl-config)# set fft_size 512 Updated fft_size 512 FullMAX (dl-config) # show fft_size fft_size 512 ︳ This field indicates the number of OFDMA symbols allocated for downlink transmission in the OFDMA frame Command FullMAX(dl-config)# set dl_frame-duration FullMAX(dl-config)# show dl_frame-duration Purpose The command allows the user to updates the downlink frame duration The command allows the user to display the downlink frame duration Privileges A/O Example: FullMAX (dl-config)# set dl_frame-duration 20 Updated dl_frame-duration 20 ofdma symbols FullMAX (dl-config) # show dl_frame-duration dl_frame-duration 20 ofdma symbols ︳ This field indicates the number of OFDMA symbols allocated for uplink transmission in the OFDMA frame. Command FullMAX(dl-config)# set ul_frame-duration FullMAX(dl-config)#show ul_frame-duration Purpose Privileges The command allows the user to updates A the uplink frame duration. The command allows the user to display the uplink frame duration. A/O Example: FullMAX (dl-config)# set ul_frame-duration 10 Updated ul_frame-duration 10 ofdma symbols FullMAX (dl-config) # show ul_frame-duration ul_frame-duration 10 ofdma symbols Full Spectrum Confidential 43 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 ︳ ︳ Number of downlink zones for the BS Command FullMAX(dl-config)#set dl_zones_num FullMAX(dl-config)#show dl_zones_num Purpose Privileges The command allows the user to update A the number of downlink zones. The command allows the user to display the number of downlink zones. A/O Example: FullMAX (dl-config)# set dl_zones_num 2 Updated dl_zones_num 2 zones FullMAX (dl-config) # show dl_zones_num dl_zones_num 2 zones ︳ ︳ Number of uplink zones for the BS Command FullMAX(dl-config)# set ul_zones_num FullMAX(dl-config)#show ul_zones_num Purpose The command allows the user to updates the number of uplink zones The command allows the user to display the number of uplink zones. Privileges A/O Example: FullMAX(dl-config)# set ul_zones_num 2 Updated ul_zones_num 2 zones FullMAX (dl-config)# show ul_zones_num ul_zones_num 2 zones 4.2.5 zone-config The group defines the commands that monitors or updates the downlink and uplink zones attributes. The user upon entering the zone-config command locks into the CLI to execute commands only related to BS downlink and uplink zones characteristics. FullMAX# FullMAX# zone-config FullMAX(zone-config)# Full Spectrum Confidential 44 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Command FullMAX# zone-config Purpose The command allows the user to lock into the group zone-config and execute all the commands related to the group. Privileges A/O The downlink zone identifier ,the index of the first zone will always be 0 Command FullMAX(zone-config)#show dl-zone-id Purpose The command allows the user to display the avaliable DL zone ids. Privileges A/O Example: FullMAX(zone-config)#show dl-zone-id dl-zone-id 0 dl-zone-id 1 dl-zone-id 2 This table contains zone attributes that characterize a downlink zone Command FullMAX(zone-config)# show dl_zone-table Purpose The command allows the user to display the list of downlink zones. FullMAX(zone-config)# show dl-zone-table dl-zone-stc 0 dl-perm-type pusc dl-perm-base 17 dl-start-symbol 11 dl-all-sc YES dl-cinr-threshold 2 dB Privileges A/O Permutation type of this zone Command FullMAX(zone-config)# set dl-perm-type FullMAX(zone-config)# show dl-perm-type Purpose The command allows the user to update the downlink permutation type of zone The command allows the user to display the permutation type of zone Full Spectrum Confidential Privileges A/O 45 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Example: FullMAX(zone-config)# set dl-perm-type 0 1 Updated dl-perm-type of zone 0 to pusc (1) FullMAX(zone-config)# show dl-perm-type 0 dl-perm-type of zone 0 is pusc (2) Downlink zone Command FullMAX(zone-config)# set dl-perm-zone FullMAX(zone-config)#show dl-perm-zone Purpose Privileges The command allows the user to update the downlink permutation zone of zone The command allows the user to A/O display the permutation zone of zone Example: FullMAX(zone-config)# set dl-zone-stc 0 2 Updated dl-zone-stc of zone 0 to nonstc (2) FullMAX(zone-config)# show dl-zone-stc 0 dl-zone-stc of zone 0 is nonstc (2) Permutation base for this zone Command FullMAX(zone-config)# set dl-perm-base FullMAX(zone-config)# show dl-perm-base Purpose Privileges The command allows the user to update the A downlink permutation base of zone The command allows the user to display the permutation base of zone A/O Example: FullMAX(zone-config)# set dl-perm-base 0 17 Updated dl-perm-base of zone 0 to 17 FullMAX(zone-config)# show dl-perm-base dl-perm-base of zone 0 is 17 Full Spectrum Confidential 46 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Index of the starting symbol for this zone. Command FullMAX(zone-config)# set dl-start-symbol FullMAX(zone-config)#show dl-start-symbol Purpose The command allows the user to update the start-symbol downlink of Privileges The command allows the user to display the start-symbol of A/O Example: FullMAX (zone-config)# set dl-start-symbol 0 5 Updated dl-perm-type of zone 0 to 5 FullMAX(zone-config)# show dl-start-symbol dl-start-symbol of zone 0 is 5 Use all subchannels. 1 (true): use_all_SC=1 2 (false): use_all_SC=0 Downlink zone parameters – Command FullMAX (zone-config)#set dl-all-sc FullMAX(zone-config)#show dl-all-sc Purpose The command allows the user to update the downlink zone–allsubchannels parameter The command allows the user to display the all subchannels parameter of Privileges A/O Example: FullMAX(zone-config)# set dl-all-sc 0 YES Updated dl-all-sc of zone 0 to YES FullMAX (zone-config) # show dl-all-sc 0 dl-all-sc of zone 0 is YES Threshold of the maximum of the standard deviations of the individual bands CINR measurements over time to trigger mode transition from zone 0 to this zone. Command FullMAX(zone-config)# set dl-cinr-threshold Purpose Privileges The command allows the user to update A the CINR threshold for Full Spectrum Confidential 47 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(zone-config)#show dl-cinr-threshold The command allows the user to display the CINR threshold for A/O Example: FullMAX(zone-config)# set dl- cinr-threshold 0 2 Updated dl-cinr-threshold of zone 0 to 2 dB FullMAX(zone-config)# show dl-cinr-threshold 0 dl-cinr-threshold of zone 0 is 2 dB The uplink zone identifier , The index of the first uplink zone will always be 0 Command FullMAX(zone-config)# show ul-zone-id Purpose The command allows the user to display the ul zone indixes avaliable Privileges A/O Example: FullMAX(zone-config)#show ul-zone-id ul-zone-id 0 ul-zone-id 1 ul-zone-id 2 Displays the Uplink zones table Command FullMAX(zone-config)#show ul_zone-table Purpose The command allows the user to display the list of uplink zones. Privileges A/O Example: FullMAX(zone-config)# show ul-zone-table 0 ul-perm-type for zone-id (0) : nonstc(2) ul-perm-base for zone-id (0) : 17 ul-start-symbol for zone-id (0) : 11 ul-alloc-bitmap for zone-id (0) : 3 ul-cinr-threshold for zone-id (0) : 2 dB A zone permutation type Command FullMAX(zone-config)#set ul-perm-type Purpose The command allows the user to update the uplink permutation type of Full Spectrum Confidential Privileges 48 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(zone-config)#show ul-perm-type The command allows the user to display the permutation type of zone A/O Example: FullMAX(zone-config)# set ul-perm-type 0 2 Updated ul-perm-type for zone-id(0): to non-stc (2) FullMAX(zone-config)# show ul-perm-type 0 ul-perm-type for zone-id (0) : non-stc (2) Determines the Permutation Base parameter for the zone, permutation to be used on this uplink zone Command FullMAX(zone-config)# set ul-perm-base FullMAX(zone-config)#show ul-perm-base Purpose Privileges The command allows the user to update the uplink permutation base of The command allows the user to A/O display the permutation base of Example: FullMAX(zone-config)# set ul-perm-base 0 17 Updated ul-perm-base for zone-id (0) to 17 FullMAX (zone-config) # show ul-perm-base ul-perm-base for zone-id (0) : 17 Index of the starting symbol for this zonehat segment Command FullMAX(zone-config)# set ul-start-symbol FullMAX(zone-config)# show ul-start-symbol Purpose The command allows the user to update the start-symbol uplink of The command allows the user to display the start-symbol of Privileges A/O Example: FullMAX (zone-config)# set ul-start-symbol 0 5 Updated ul-start-symbol for zone-id (0) to 5 FullMAX (zone-config) # show ul-start-symbol Full Spectrum Confidential 49 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 ul-start-symbol for-id zone-id(0) :5 This is a bitmap describing the physical sub-channels allocated to the segment in the UL, when using the uplink PUSC permutation. The LSB of the first byte shall corrspond to subchannel 0. For any bit that is not set, the corresponding subchannel shall not be used by the SS on that segment Command FullMAX(zone-config)# set ul-alloc-bitmap FullMAX(zone-config)#show ul-alloc-bitmap Purpose The command allows the user to update the uplink zone – allocation bitmap parameter The command allows the user to display the allocation bitmap parameter of zone Privileges A/O Example: FullMAX(zone-config)# set ul-alloc-bitmap 0 010101 Updated ul-alloc-bitmap for zone-id (0) : to 010101 FullMAX(zone-config) # show ul-alloc-bitmap 0 ul-alloc-bitmap of zone-id (0) : 01010101 This object is used to ensure that the write operation to multiple columns is guaranteed to be treated as atomic operation by agent. Command FullMAX(zone-config)# set ul-cinr-threshold FullMAX(zone-config)# show ul-cinr-threshold Purpose The command allows the user to update the CINR threshold for zone The command allows the user to display the CINR threshold for zone Privileges A/O Example: FullMAX(zone-config)# set ul-cinr-threshold 0 2 Updated ul-cinr-threshold for zone-id (0) to 2 dB FullMAX(zone-config)# show ul-cinr-threshold 0 ul-cinr-threshold for zone-id (0): 2 dB Full Spectrum Confidential 50 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 4.2.6 bs-cap-config The group defines the commands to configure the basic capabilities of BS. The user upon entering the bs-capability-config command locks into the CLI to execute commands only related to basic capabilities of BS. FullMAX# FullMAX# bs-cap-config FullMAX(bs-cap-config)# Command FullMAX# bs-cap-config Purpose The command allows the user to lock into the group bs-cap-config and execute all the commands related to the group. Privileges A/O Description Command FullMAX(bs-caponfig)#show all Purpose Privileges The command allows the user to A/O display values of all the attributes of bs-cap-config group Example: FullMAX(bs-cap-config)# show all capability-ttg-transition-gap 34 microseconds capability-rtg-transition-gap 34 microseconds capability-pn-window-size 1000 capability-number-of-ul-harq-channel 0 capability-number-of-dl-harq-channel 0 This parameter indicates the configured transition speed SSTTG for TDD and H-FDD SSs. The usage is defined by ss-transistion-gap Command FullMAX(bs-cap-config)# set capability-ttg-transitio-gap FullMAX(bs-cap-config)# show capability-ttg-transitio-gap Purpose The command allows the user to update the TTG transition gap parameter Privileges The command allows the user to display the TTG transition gap parameter A/O Full Spectrum Confidential 51 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Example: FullMAX(bs-cap-config)# set capability-ttg-transitio-gap Updated capability-ttg-transitio-gap FullMAX(bs-cap-config)# show capability-ttg-transitio-gap capability-ttg-transitio-gap This parameter indicates the configured transition speed SSTTG for TDD and H-FDD SSs. The usage is defined by ss-transition-gap. Command FullMAX(bs-cap-config)# set capability-rtg-transition-gap FullMAX(bs-cap-config)#show capability-rtg-transition-gap Purpose The command allows the user to update the RTG transition gap. Privileges The command allows the user to display the RTG transition gap. A/O Example: FullMAX(bs-cap-config)# set capability-rtg-transition-gap 30 Updated capability-rtg-transition-gap FullMAX (bs-cap-config)# show capability-rtg-transitiongap capability-rtg-transition-gap 30 4.2.7 bs-burst-profile The group defines the commands to burst profile commands of BS. The user upon entering the bs-burst-profile command locks into the CLI to execute commands only related to BS burst profile of BS. FullMAX# FullMAX# bs-burst-profile FullMAX(bs-burst-profile)# Command FullMAX#bs-burst-profile Purpose The command allows the user to lock into the group bs-burst-profile and execute all the commands related to the group. Full Spectrum Confidential Privileges A/O 52 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 The uplink interval usage code inidicates the uplink burst profile in the ucd message and is used along the index to identify the ucd-fec-code. Max uiuc -index range for OFDMA PHY <0- 10 > Command FullMAX(bs-burst-Profile)# show uiuc-index Purpose The command allows the user to display the Uplink intetrval usage codes indexes avaliable in the MAC Privileges A/O Example: FullMAX(bs-burst-profile)# show uiuc-index uiuc-index 0 uiuc-index 1 uiuc-index 2 uiuc-index 3 Uplink FEC code type and modulation type Command FullMAX (bs-burst-rofile)# show dcd-fec-code-type Purpose The command allows the user to display the different FEC and coding options for uplink burst profile. Privileges A/O Example: FullMAX(bs-burst-profile)# show ucd-fec-code-type 1 ucd-fec-code-type for uiuc-index (1) : qpskCc1Over2(0), qpskCc3Over4(1), sixteenQamCc1Over2(2), sixteenQamCc3Over4(3), sixtyFourQamCc1Over2(4), sixtyFourQamCc2Over3(5), sixtyFourQamCc3Over4(6), qpskBtc1Over2(7), qpskBtc3Over4Or2Over3(8), sixteenQamBtc3Over5(9), sixteenQamBtc4Over5(10), sixtyFourQamBtc2Over3Or5Over8(11), sixtyFourQamBtc5Over6Or4Over5(12), qpskCtc1Over2(13), reserved14(14), qpskCtc3Over4(15), sixteenQamCtc1Over2(16), sixteenQamCtc3Over4(17), sixtyFourQamCtc1Over2(18), sixtyFourQamCtc2Over3(19), sixtyFourQamCtc3Over4(20), sixtyFourQamCtc5Over6(21), qpskZtCc1Over2(22), qpskZtCc3Over4(23), sixteenQamZtCc1Over2(24), sixteenQamZtCc3Over4(25), sixtyFourQamZtCc1Over2(26), sixtyFourQamZtCc2Over3(27), Full Spectrum Confidential 53 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 sixtyFourQamZtCc3Over4(28), qpskLdpc1over2(29), qpskLdpc2over3A(30), qpskLdpc3over4A(31), sixteenQamLdpc1over2(32), sixteenQamLdpc2over3A(33), sixteenQamLdpc3over4A(34), sixtyFourQamLdpc1over2(35), sixtyFourQamLdpc2over3A(36), sixtyFourQamLdpc3over4A(37), qpskLdpc2over3B(38), qpskLdpc3over4B(39), sixteenQamLdpc2over3B(40), sixteenQamLdpc3over4B(41), sixtyFourQamLdpc2over3B(42), sixtyFourQamLdpc3over4B(43), qpskCcOptIntv1over2(44), qpskCcOptIntv3over4(45), sixteenQamCcOptIntv1over2(46), sixteenQamCcOptIntv3over4(47), sixtyFourQamCcOptIntv2over3(48), sixtyFourQamCcOptIntv3over4(49), qpskLdpc5over6(50), sixteenQamLdpc5over6(51), sixtyFourQamLdpc5over6(52) The Downlink interval usage code inidicates the uplink burst profile in the ucd message and is used along the index to identify the Dcd-fec-code. Max diuc -index range for OFDMA PHY <0- 12 > Command FullMAX(bs-burst-Profile)# show diuc-index Purpose The command allows the user to display the Downlink interval usage codes indexes avaliable in the MAC Privileges A/O Example: FullMAX(bs-burst-profile)# show diuc index diuc-index 0 diuc-index 1 diuc-index 2 diuc-index 3 Displays FEC and coding options for downlink burst profiles Command FullMAX (bs-burstprofile)# show dcdfec-code-type Purpose The command allows the user to display the different FEC and coding options for downlink burst profile. Privileges A/O Example: Full Spectrum Confidential 54 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX (bs-burst-profile) # show dcd-fec-code-type 2 dcd-fec-code-type for dicu-index (2) is qpskCc1Over2(0), qpskCc3Over4(1), sixteenQamCc1Over2(2), sixteenQamCc3Over4(3), sixtyFourQamCc1Over2(4), sixtyFourQamCc2Over3(5), sixtyFourQamCc3Over4(6), qpskBtc1Over2(7), qpskBtc3Over4Or2Over3(8), sixteenQamBtc3Over5(9), sixteenQamBtc4Over5(10), sixtyFourQamBtc2Over3Or5Over8(11), sixtyFourQamBtc5Over6Or4Over5(12), qpskCtc1Over2(13), reserved14(14), qpskCtc3Over4(15), sixteenQamCtc1Over2(16), sixteenQamCtc3Over4(17), sixtyFourQamCtc1Over2(18), sixtyFourQamCtc2Over3(19), sixtyFourQamCtc3Over4(20), sixtyFourQamCtc5Over6(21), qpskZtCc1Over2(22), qpskZtCc3Over4(23), sixteenQamZtCc1Over2(24), sixteenQamZtCc3Over4(25), sixtyFourQamZtCc1Over2(26), sixtyFourQamZtCc2Over3(27), sixtyFourQamZtCc3Over4(28), qpskLdpc1over2(29), qpskLdpc2over3A(30), qpskLdpc3over4A(31), sixteenQamLdpc1over2(32), sixteenQamLdpc2over3A(33), sixteenQamLdpc3over4A(34), sixtyFourQamLdpc1over2(35), sixtyFourQamLdpc2over3A(36), sixtyFourQamLdpc3over4A(37), qpskLdpc2over3B(38), qpskLdpc3over4B(39), sixteenQamLdpc2over3B(40), sixteenQamLdpc3over4B(41), sixtyFourQamLdpc2over3B(42), sixtyFourQamLdpc3over4B(43), qpskCcOptIntv1over2(44), qpskCcOptIntv3over4(45), sixteenQamCcOptIntv1over2(46), sixteenQamCcOptIntv3over4(47), sixtyFourQamCcOptIntv2over3(48), sixtyFourQamCcOptIntv3over4(49), qpskLdpc5over6(50), sixteenQamLdpc5over6(51), sixtyFourQamLdpc5over6(52) 4.2.8 bs-ss-action The bs-ss-action group define the commands that monitors or updates the actions specified for SS. The user upon entering the bs-ss-action command locks into the CLI to execute commands only related to BS private mib. FullMAX# FullMAX#bs-ss-action FullMAX(bs-ss-action)# Command FullMAX#bs-ss-action Purpose The command allows the user to lock into Full Spectrum Confidential Privileges A/O 55 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 the group bs-ss-action and execute all the commands related to the group. Reset action performed on SS. Command FullMAX(bs-ss-action)#set reset-ss Purpose The command allows the user to perform reset action on SS Privileges Example: FullMAX(bs-ss-action)# set reset-ss 1 0A1234:5678AB Reset-ss message sent to 0A1234:5678AB Abort action performed on SS. Command FullMAX(bs-ss-action)#set abort-ss [-d:dl-freq] [u:up-id] Purpose The command allows the user to perform the abort action on SS Privileges A/O FullMAX(bs-ss-action)# set abort-ss 1 abort-ss message sent to FullMAX(bs-ss-action)# set abort-ss 2 0A1234:5678AB -d:210000 abort-ss message with downlink frequency override 210000 KHz sent to 0A1234:5678AB De-registration action on SS Command FullMAX(bs-ss-action)# set abort-ss [d:dl-freq] [-u:up-id] Purpose The command allows the user to perform the abort action on SS FullMAX(bs-ss-action)# set de-reg-ss 0A1234:5678AB 2 reg-ss message sent to 0A1234:5678AB with limited transmission code (2) FullMAX(bs-ss-action)# set de-reg-ss 0A1234:5678AB 1 Full Spectrum Confidential Privileges A/O De- 56 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 De-reg-ss message sent to 0A1234:5678AB with no transmission code (1) 4.2.9 ss-registered The ss-registered group defines the commands that monitors or updates the standard mib related information. The user upon entering the ss-registered command locks into the CLI to execute commands only related to SS registered table mib. FullMAX# FullMAX# ss-registered FullMAX ss-registered)# Command FullMAX# ss-registered Purpose The command allows the user to lock into the group ss-registered and execute all the commands related to the group. Privileges A/O The MAC address of SS is received in the RNG-REQ message when SS registers ,this MAC address is entered in to the Bs Registered Ss Table. Command FullMAX(ssregistered)# show registered-ss-macaddress Purpose The command allows the user display all the SS MAC addresses. Privileges A/O Example: FullMAX(ss-registered)# show registered-ss-mac-address Registered SS MAC Addresses are: registered-ss-mac-address 1 001BFE:01020A registered-ss-mac-address 2 001BAA:01030F registered-ss-mac-address 3 001BEF:01F01A SS’s Maximum available power for QPSK in dBm. This parameter is only applicable to systems supporting the SCa, OFDM or OFDMA PHY. Command FullMAX(ss-registered)# show max-tx-power-qpsk Purpose The command allows the user display SS’s Maximum available power for QPSK in dBm. Here key is SS’s MAC address. Full Spectrum Confidential Privileges A/O 57 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Example: FullMAX(ss-registered)# show max-tx-power-qpsk 001BFE:01020A max-tx-power-qpsk 27 dBm SS’s Maximum available power for 16-QAM constellations in dBm. This parameter is only applicable to systems supporting the SCa, OFDM or OFDMA PHY. Command FullMAX(ssregistered)# show maxtx-power-16qam Purpose The command allows the user display SS’s Maximum available power for 16QAM in dBm. Here key is SS’s MAC address. Privileges A/O Example: FullMAX(ss-registered)# show max-tx-power-16qam 001BAA:01030F max-tx-power-16qam 20 dBm SS’s Maximum available power for 64-QAM constellations in dBm. This parameter is only applicable to systems supporting the SCa, OFDM or OFDMA PHY. Command FullMAX(ssregistered)# show maxtx-power-64qam Purpose The command allows the user display SS’s Maximum available power for 64QAM in dBm. Here key is SS’s MAC address. Privileges A/O Example: FullMAX(ss-registered)# show max-tx-power-64qam 001BEF:01F01A max-tx-power-64qam 25 dBm 4.2.10 ss-ip The bs-ss-ip group define the commands that monitors or updates the BsSsIp related information. The user upon entering the ss-ip command locks into the CLI to execute commands only related to BsSsIpTable defined in the private mib. FullMAX# FullMAX# ss-ip FullMAX(ss-ip)# Full Spectrum Confidential 58 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Command FullMAX# ss-ip Purpose The command allows the user to lock into the group ss-ip and execute all the commands related to the group. Privileges A/O This table contains the IP configuration information of Subcriber station's as set by DHCP Relay function in the Base Station. Command FullMAX(ss-ip)#show ss-ip-table Purpose The command allows the user display the MS IP table. Privileges A/O Example: FullMAX (bs-private) # show ss-ip-table 001BFE:01020A ss-mac-address 001BFE:01020A ss-ip-address 192.168.0.1 ss-subnet-mask 192.168.0.0 The MAC address of SS is received from the RNG-REQ message. When SS registers, this MAC address is entered into the table, and used as the identifier to the SS. Command FullMAX (ss-ip) # show ss-mac-address Purpose The command allows the user display the MS MAC address of all MS. Privileges A/O Example: FullMAX (ss-ip) # show ss-mac-address ss-mac-addres 00A1B3:01AB03 ss-mac-addres 00A1B3:010203 ss-mac-addres 00A1B3:010405 The subnet mask address of SS as received from BS DHCP Relay. When SS Registers, this IP address is entered into the table, and used as the identifier to the SS. Command FullMAX (ss-ip) # show ss-ip-address Purpose The command allows the user display the IP address. Privileges A/O Example: FullMAX(ss-ip)# show ss-ip-address 00A1B3:01AB03 Full Spectrum Confidential 59 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 ss-ip-addres 192.168.0.1 The IP address of SS is received from the DHCP-Relay in the BS when SS register, this IP address is entered into the table, and used as the identifier to the SS. Command FullMAX(ss-ip)#show ss-ip-address Purpose The command allows the user display the subnet mask of all the MS. Privileges A/O Example: FullMAX(ss-ip)# show ss-subnet-mask 00A1B3:01AB03 ss-subnet-mask 192.168.0.0 4.2.11 device The device group define the commands that monitors or updates the device related information in the private MIB. The user upon entering the device command locks into the CLI to execute commands only related to device. FullMAX# FullMAX# device FullMAX(device)# Command FullMAX# device Privileges A/O Purpose The command allows the user display the device type (BS/MS/SS) Privileges A/O Purpose The command allows the user to lock into the group device and execute all the commands related to the group. Type of device (BS/MS/SS). Command FullMAX(device) # show type Example: FullMAX(device)# show type type BS The geographical position of the device , i.e. the real number describing the longitude and latitusde encoded as a printable string. Full Spectrum Confidential 60 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Longitude - the precision is within the range -90..90 degrees.Positive numbers indicate locations north of the equator. Latitude - The precision is within the range -180..180 degrees.Positive numbers indicate locations east of the prime meridian Command FullMAX(device)# set gpos FullMAX(device)# show gpos Example: Purpose The command allows the user to update the geographical position of the device The command allows the user display geographical position of the device. Privileges A/O FullMAX(device)# set gpos 64.000 88.3400 updated gpos 64.000 88.3400 FullMAX(device) # show gpos gpos 64.000 88.3400 The absolute time of last device boot up. Command FullMAX(device)# show boot-time Purpose The command allows the user display the device boot up time. Privileges A/O Example: FullMAX(device)# show boot-time boot-time 230404:18052008 Setting this object to TRUE causes the device to write all configuration changes in FLASH memory. On next boot the changes will be relevant. If this operation does not occur, configuration changes will not be maintained through reset Reading this object always returns FALSE Command FullMAX(device)# set commit-save Purpose The command allows the user update the commit-save to TRUE . Privileges FullMAX(device)# show commit-save The command allows the user display A/O the commit-save Example: Full Spectrum Confidential 61 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(device)# set commit-save TRUE Updated commit-save TRUE FullMAX(device)# show commit-save commit-save FALSE GPS card availability in the device. Command FullMAX(device)#sho w gps-card Purpose The command allows the user display the availability of GPS card in the device. Privileges A/O Example: FullMAX(device)# show gps-card gps-card YES Hardware version of baseband processor card. Command FullMAX(device)#show bpc-hw-version Purpose The command allows the user display the hardware version of baseband processor card. Privileges A/O Example: FullMAX(device)# show bpc-hw-version bpc-hw-version 1.10 Hardware version of the Analog Front End (AFE) Command FullMAX(device)#show afe-hw-ver Purpose The command allows the user display the hardware version of AFE. Privileges A/O Example: FullMAX(device)# show afe-hw-ver device-afe-hw-version 1.3 Software version of the Analog Front End (AFE) Command Purpose Full Spectrum Confidential Privileges 62 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(device)#show afe-sw-ver The command allows the user display the software version of AFE. A/O Example: FullMAX(device)# show afe-sw-ver device-afe-sw-version 1.3 Software version of the device general embedded software Command FullMAX(device)#show build-sw-ver Purpose The command allows the user display the software version of the software build Privileges A/O Example: FullMAX(device)# show build-sw-ver build-sw-version 4.2.12 Measurements The Measurement group defines the commands that monitors or updates the measurement related information in the private MIB. The user upon entering the device command locks into the CLI to execute commands only related to Measurement. FullMAX# FullMAX# measurement FullMAX(measurement)# Temperature degree in Celsius Command FullMAX(measurement)#show temperature Purpose The command allows the user display temperature of the device. FullMAX(measurement)#track [- The command allows the user to rN] [-tN] temperature display real time temperature sample of the device. Privileges A/O A/O Example: FullMAX(measurement)# show temperature Temperature 45 degrees-Celsius FullMAX(measurement)# track –r3 –i2 temperature Temperature 45 degrees-Celsius Temperature 46 degrees-Celsius Temperature 45 degrees-Celsius Full Spectrum Confidential 63 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Voltage measurement Command FullMAX(measurement)# show voltage FullMAX(measurement)# track [-rN] [-tN] voltage Purpose The command allows the user display voltage of the device. The command allows the user to display multiple voltage samples of the device. Privileges A/O A/O Example: FullMAX (measurement) # show voltage Voltage 3 volts FullMAX (measurement) # track –r3 –i10 voltage Voltage 3 volts Voltage 3 volts Voltage 3 volts Current measurements Command FullMAX(measurement)# show current FullMAX(measurement)# track [-rN] [-tN] current Purpose Privileges The command allows the user display A/O the current in the device. The command allows the user to A/O display multiple current measurements in the device. Example: FullMAX (measurement) # show current Current 2 amp FullMAX (measurement) # track –r4 current Current 2 amp Current 2 amp Current 2 amp Transmit power Command FullMAX(measurement )# show tx-power FullMAX(measurement)# Purpose The command allows the user display the transmit power. Privileges A/O The command allows the user to display A/O Full Spectrum Confidential 64 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 track [-rN] [-tN] txpower multple transmit power measurements. Example: FullMAX (measurement) # show tx-power Tx-power 45 dBm FullMAX (measurement) # track –r2 tx-power Tx-power 45 dBm Tx-power 43 dBm Receive power Command FullMAX(measurement)# show rx-power FullMAX(measurement)# track [-rN] [-tN] rxpower Purpose The command allows the user display the receive power. Privileges A/O The command allows the user to display multiple receive power measurements. A/O Example: FullMAX(measurement)# show rx-power rx-power 45 dBm FullMAX(measurement)# track –r2 -i2 rx-power rx-power 45 dBm rx-power 45 dBm Read the temperature from the Analog Front End. Command FullMAX(measurement)# show afe-temperature FullMAX(measurement)# track [-rN] [-tN] afe-temperature Purpose The command allows the user display temperatue from Analog Front End. The command allows the user to track the temperatue from Analog Front End. Privileges A/O A/O Example: FullMAX(measurement)# show afe-temperatue afe-temperature 27 celcius FullMAX(measurement)# track -r4 -i30 afe-temperatue afe-temperature 27 celcius afe-temperature 27 celcius afe-temperature 27 celcius Full Spectrum Confidential 65 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 afe-temperature 27 celcius Read the Receive Signal Strength Indicator (RSSI) from the Analog Front End. Command FullMAX(measurement)#show afe-rssi FullMAX(measurement)#track [-rN] [-tN] afe-rssi Purpose The command allows the user display RSSI from Analog Front End. The command allows the user to track RSSI from Analog Front End. Privileges A/O A/O Example: FullMAX(measurement)# show afe-rssi afe-rssi 80 dBm FullMAX(measurement)# track -r3 -i30 afe-rssi afe-rssi 80 dBm afe-rssi 80 dBm afe-rssi 80 dBm pkm–config 4.2.13 – The Pkm-Config group defines the commands that moniters or updates the Private Key Management Version 2 Realated information in the Standard MIB .The user upon entering the pkm-config command locks into this group to execute commands only related to this group. FullMAX# FullMAX# pkm–config FullMAX(pkm–config) Command FullMAX# pkm –config Purpose The command allows the user to lock to pkm-config group and display the pkm –config prompt. Privileges A/O FullMAX# pkm–config This table conatins the configuration of the pkm attributes that are needed to pkm operation. Full Spectrum Confidential 66 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Command FullMAX(pkm– config)# show pkmv2-config-table Purpose The command allows the user display all the Pkm V2 Config table parameter Privileges A/O values. Example: FullMAX(pkm–config)# show pkm-v2-config-table pmk-pre-handshake-lifetime 10 second pmk-lifetime 3600 seconds sa-tek-challenge-timeout 10000 milliseconds max-sa-tek-challenge 3 max-sa-tek-request 3 Defines the PkmPmkPrehandshakeLifetime. Command FullMAX(pkm– config)#set pkm-pmkpre-handshakelifetime FullMAX(pkm–config)#show pkm-pmk-pre-handshakelifetime Purpose The command allows the user update Privileges A/O PkmPmkPrehandshakeLifetime. The command allows the user to display PkmPmkPrehandshakeLifetime A/O value Example: FullMAX(pkm–config)# set pkm-pmk-pre-handshake-lifetime 11 Updated pkm-pmk-pre-handshake-lifetime 11 second FullMAX(pkm–config)# show pkm-pmk-pre-handshake-lifetime pmk-pre-handshake-lifetime 10 second Defines the PMK life time Command FullMAX(pkm– config)#set pkm-pmklifetime FullMAX(pkm–config)#show pkm-pmk-lifetime Purpose The command allows the user to update pkm-pmk-lifetime value Privileges The command allows the user display pkm-pmk-lifetime. A/O Full Spectrum Confidential 67 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Example: FullMAX(pkm–config) # set pkm-pmk-lifetime 3300 Updated pkm-pmk-lifetime 3300 seconds FullMAX(pkm–config) # show pkm-pmk-lifetime 3600 seconds pkm-pmk-lifetime 3300 seconds This object defines the timeout value for SA-TEk challenge Retransmission. Command Purpose FullMAX(pkm– config)#set sachallenge-timeout FullMAX(pkm–config)#show sa-challenge-timeout The command allows the user to update A sa-challenge-timeout. The command allows the user display sa-challenge-timeout. Pri vile ges A/O Example: FullMAX(pkm–config) # set sa-challenge-timeout 666 updated value of sa-tek-challenge-timeout 666 millisecond FullMAX(pkm–config) # show sa-challenge-timeout sa-tek-challenge-timeout 10000 milliseconds This object defines the maximum number of SA-TEK-Challenge Transmissions Command FullMAX(pkm– config)#set max-satek-challenge FullMAX(pkm–config)#show max-sa-tek-challange Purpose The command allows the user to update sachallenge-timeout. Privileges The command allows the user display max- A/O sa-tek-challenge. Example: FullMAX(pkm–config)# set max-sa-tek-challange 2 updated value of max-sa-tek-challenge 2 Full Spectrum Confidential 68 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(pkm–config)# show max-sa-tek-challange max-sa-tek-challenge 3 This object defines the maximum number of SA-TEK -Request retransmission. Command FullMAX(pkm– config)#set max-satek-request FullMAX(pkm–config)#show max-sa-tek-request Purpose Privileges The command allows the user to update A max-sa-tek-request. The command allows the user to display max-sa-tek-request. A/O Example: FullMAX(pkm–config)# set max-sa-tek-request 2 updated value of max-sa-tek-request 2 FullMAX(pkm–config)# show max-sa-tek-request max-sa-tek-request 3 The command allows the user to display all the parameters of the tables in this group. Command FullMAX(pkm–config)#show all Purpose The command allows the user to display all the parameters values of the in this group. Privileges A/O FullMAX(pkm–config) # show all pmk-pre-handshake-lifetime 10 second pmk-lifetime 3600 seconds sa-tek-challenge-timeout 10000 milliseconds max-sa-tek-challenge 3 max-sa-tek-request 3 4.2.14 bs-private FullMAX# FullMAX# bs-private FullMAX(bs-private)# Command FullMAX#bs-private Purpose The command allows the user to lock to bs-private group and display the bsFull Spectrum Confidential Privileges A/O 69 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 private prompt. This table contains statistical information that can be used to characterize the adaptive modulation and coding performance in the uplink. Command FullMAX(bs-private)# show bs-rx-amc-count-table Purpose This command shows all the parameters and their values for AmcCountTable Privileges A/O Example: FullMAX(bs-private)# show bs-rx-amc-count-table 1 bs-rx-octets for uiuc index 1 is 0 bs-rx-packets for uiuc index 1 is 0 bs-tx-erroredpackets for uiuc index 1 is 0 The Uplink Interval Usage Code indicates the uplink burst profile in the UCD message, and is used along with ifIndex to identify an entry in the wmanIf2BsOfdmaUcdBurstProfileTable. Command FullMAX(bs-private)#show bs-rx-uiuc-index Purpose Show all the Uplink Interval Usage Code index available.A/O Privileges A/O Example: FullMAX(bs-private)# show bs-rx-uiuc-index uiuc indices are bs-ul-uiuc-index: 1 bs-ul-uiuc-index: 2 bs-ul-uiuc-index: 3 bs-ul-uiuc-index: 4 bs-ul-uiuc-index: 5 bs-ul-uiuc-index: 6 bs-ul-uiuc-index: 7 bs-ul-uiuc-index: 8 bs-ul-uiuc-index: 9 bs-ul-uiuc-index: 10 This object counts the number of octets received in the uplink using the uplink burst profile indexed by wmanPriBsRxUiucIndex. Command Purpose Full Spectrum Confidential Privileges 70 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(bs-private)#show bs-rx-octets Show the no of octet received in the uplink for the given index A/O Example: FullMAX(bs-private)# show bs-rx-octets 1 bs-rx-octets for uiuc index 1 is 0 This object counts the number of packets received in the uplinkusing the uplink burst profile indexed by UiucIndex Command FullMAX(bsprivate)#show bsrx-packets Purpose Shows the number of packets received in the uplink for the given index Privileges A/O Example: FullMAX(bs-private)# show bs-rx-packets 1 bs-rx-packets for uiuc index 1 is 0 This object counts the number of errored packets received in the uplink using the uplink burst profile indexed by UiucIndex. Command Purpose Shows the number of errored packets FullMAX(bs-private)#show received in the uplink for the given index bs-rx-erroredPackets Privileges A/O Example: FullMAX(bs-private)# show bs-rx-erroredPackets 1 bs-tx-errored packets for uiuc index 1 is 0 This table contains statistical information that can be used to characterize the adaptive modulation and coding performance in the downlink. Command FullMAX(bs-private)#show bs-tx-amc-count-table Purpose Show all the parameters and their values of the TxAmcCountTable table for the given index Privileges A/O Example: FullMAX(bs-private)# show bs-tx-amc-count-table 1 Full Spectrum Confidential 71 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 bs-tx-octets for diuc index 1 is 0 bs-tx-packets for diuc index 1 is 0 The Downlink Interval Usage Code indicates the downlink burst profile in the DCD message. Command FullMAX(bs-private)#show bs-tx-diuc-index Purpose Show all the available Downlink Interval Usage indices. Privileges A/O Example: FullMAX(bs-private)# show bs-tx-diuc-index diuc indices are bs-dl-diuc-index: 0 bs-dl-diuc-index: 1 bs-dl-diuc-index: 2 bs-dl-diuc-index: 3 bs-dl-diuc-index: 4 bs-dl-diuc-index: 5 bs-dl-diuc-index: 6 bs-dl-diuc-index: 7 bs-dl-diuc-index: 8 bs-dl-diuc-index: 9 bs-dl-diuc-index: 10 bs-dl-diuc-index: 11 bs-dl-diuc-index: 12 This object counts the number of octets transmitted in the downlink using the downlink burst profile indexed by DiucIndex. Command FullMAX(bs-private)# show bs-tx-octets Purpose Shows the number of octets transmitted in the downlink for the given index Privileges A/O Example: FullMAX(bs-private)# show bs-tx-octets 1 bs-tx-octets for diuc index 1 is 0 This object counts the number of packets transmitted in the downlink using the downlink burst profile indexed by Diuc Index. Command Purpose Full Spectrum Confidential Privileges 72 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(bs-rivate)#show bs-tx-packets Shows the number of packets transmitted in the downlink for the given index A/O Example: FullMAX(bs-private)# show bs-tx-packets 1 bs-tx-packets for diuc index 1 is 0 This Table measures service flow traffic . Command FullMAX(bs-private)#show cmn-sf-table Purpose This command show all the parameters and their values of Cmnsf-table. Privileges A/O Example: FullMAX(bs-private)# show cmn-sf-table 2001 sf-total-octets for sfid 2001 is 100 sf-total-pkts for sfid 2001 is 2 sf-errored-pkts for sfid 2001 is 1 sf-frag-orig for sfid 2001 is 1 sf-frag-total for sfid 2001 is 2 sf-missing-frag for sfid 2001 is 0 This is a 32 bit quantity that uniquely identifies a service flow to both the subscriber station and base station. Command FullMAX(bs-private)#show cmn-pm-sfid Purpose This command shows all the avaliable Service Flow Id's Avaliable for a particular MSID. Privileges A/O Example : FullMAX(bs-private)# show cmn-pm-sfid 112233:445566 cmn-pm-sfid 2001 cmn-pm-sfid 2002 cmn-pm-sfid 2003 cmn-pm-sfid 2006 This determines the total octets received/transmitted on this service flow. Command FullMAX(bs-private)# show sf-total-octets Purpose This command allows the user to diplay the total octets received or Full Spectrum Confidential Privileges A/O 73 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 transmitted for this service-flow. Example: FullMAX(bs-private)#show sf-total-octets 2001 sf-total-octets for sfid (2001) : 1000 This determines the total number of packets received /transmitted on this service flow. Command FullMAX(bs-private)#show sf-total-pkts Purpose This Command allows the user to display the total packets received or trasmitted for this service-flow Privileges A/O Example: FullMAX(bs-private)#show sf-total-pkts 2001 sf-total-pkts for sfid (2001): 22 This determines number of packets that were dropped due to missing fragments / bad ARQ blocks. Command FullMAX(bs-private)#show sf-errored-pkts Purpose This Command Allows the user to display the total errored packets received or transmitted for this service flow. Privileges A/O Example: FullMAX(bs-private)# show sf-errored-pkts 2001 sf-errored-pkts for sfid (2001): 1 This determines number of fragments / ARQ blocks originally transmitted/received on this service flow. Command FullMAX(bs-private)#show sf-frag-orig Purpose This Command allows the user to display the total fragments received or transmitted originally on this service flow. Privileges A/O Example: FullMAX(bs-private)#show sf-frag-orig 2001 sf-frag-orig for sfid (2001) : 2 Full Spectrum Confidential 74 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 This determines total fragments / ARQ blocks transmitted / received on this service flow. Command FullMAX(bs-private)#show sf-frag-total Purpose This Command allows the user to display the total fragments received or transmitted on this service flow. 2001 Example: FullMAX(bs-private)# show sf-frag-total sf-frag-total for sfid (2001): 2 Privileges A/O Description This determines the number of missing received fragments received or NACK. Command FullMAX(bs-private)# show sf-missing-frag Purpose This command allows the user to display the number of missing received fragments or NACK. Privileges A/O Example: FullMAX(bs-private)# show sf-missing-frag 2001 sf-missing-frag for sfid (2001): 1 4.2.15 trap-config This Command allows the user to lock to trap config group. Command Purpose This command allows the user FullMAX # trapto Locks to the trap config config group and displays the coresponding group prompt. Privileges A/O Example: FullMAX # trap-config FullMAX(trap-config) # The object is used to enable or disable Base Station traps From left to right, the set bit indicates the corresponding Base Station trap is enabled Full Spectrum Confidential 75 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 {wmanIf2BsSsStatusNotification (0), wmanIf2BsSsDynamicServiceFail (1), wmanIf2BsSsRssiStatusChange (2), wmanIf2BsSsRegister (3), wmanIf2BsSsPkmFail (4), wmanIf2BsPerformanceCounters (5)} Command FullMAX(trapconfig) # set std-trap-ctrl FullMAX(trap-config) # show std-trap-ctrl Purpose Privileges This command Allows the user to update the value of stdtrap-ctrl parameter. This command Allows the user to display the value of std-trap-ctrl parameter. A/O Example: FullMAX(trap-config) # set std-trap-ctrl 25 updated bs-trap-control {wmanIf2BsSsStatusNotification(0), wmanIf2BsSsRegister(3), wmanIf2BsPerformanceCounters (4) FullMAX(bs-private)# show std-trap-ctrl bs-trap-control enabled are { wmanIf2BsSsStatusNotification(0), wmanIf2BsSsRegister(3), wmanIf2BsPerformanceCounters (4) } The object is used to enable or disable Base Station status notification traps. The set bit indicates the corresponding Base Station trap is enabled. { unused(0), ssInitRangingSucc(1), ssInitRangingFail(2), ssRegistered(3), ssRegistrationFail(4), ssDeregistered(5), ssBasicCapabilitySucc(6), ssBasicCapabilityFail(7), ssAuthorizationSucc(8), ssAuthorizationFail(9), tftpSucc(10), tftpFail(11), sfCreationSucc(12), sfCreationFail(13) } Command FullMAX(trapconfig) # set std-trapstatus-ctrl Purpose Privileges This command Allows the user to update the value of stdtrap-status-ctrl parameter. Full Spectrum Confidential 76 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(trap-config) # show std-trapstatus-ctrl This command Allows the user to display the value of std-trap-status-ctrl parameter. A/O FullMAX(bs-private)# set std-trap-status-ctrl 10900 updated bs-trap-status-ctrl {ssInitRangingFail(2), ssRegistrationFail(4), ssBasicCapabilityFail(7),ssAuthorizationFail(9), tftpFail(11), sfCreationFail(13) } FullMAX(bs-private)# show std-trap-status-ctrl bs-trap-status-ctrl enabled are {ssInitRangingFail(2), ssRegistrationFail(4), ssBasicCapabilityFail(7),ssAuthorizationFail(9), tftpFail(11), sfCreationFail(13) } The object is used to enable or disable Base Station traps From left to right, the set bit indicates the corresponding Base Station trap is enabled. { wmanPriPowerStatusChange (0), wmanPriFanStatusChange (1), wmanPriTemperatureChange (2), wmanPriConfigChange (3), wmanPriAfeBitError (4) } Command FullMAX(trapconfig) # set private-trapctrl FullMAX(trap-config) # show private-trapctrl Purpose This command Allows the user to update the value of private-trap-ctrl parameter. Privileges This command Allows the user to display the value of private-trap-ctrl parameter. A/O FullMAX(bs-private)# set private-trap-ctrl 21 updated private-trap-ctrl { wmanPriPowerStatusChange(0), wmanPriPowerStatusChange(2), wmanPriPowerStatusChange (4)} FullMAX(bs-private)# show private-trap-ctrl private-trap-ctl enabled Full Spectrum Confidential 77 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 { wmanPriPowerStatusChange(0), wmanPriPowerStatusChange(2), wmanPriPowerStatusChange (4)} 4.2.16 lapc-config This group contains commands to manipulate the Link Adaption and Power Control configuration parameters for the Base Station MAC. Command FullMAX#lapc-config Purpose The command allows the user to lock to config group and display the config prompt. FULLMAX#lapc-config FULLMAX(lapc-config)]# Command FullMAX(lapc-config)# show uiuc Purpose Shows the values of uiuc avaliable. Example: FULLMAX(lapc-config)#show uiuc uiuc 1 uiuc 2 ︳ ︳ ︳ Command Purpose FullMAX(lapc-config)# The command sets the value of set Uplink_FEC_Code_Type Uplink_FEC_Code_Type for the given index value The command show the value of FullMAX(lapc-config)# show Uplink_FEC_Code_Type Uplink_FEC_Code_Type for the particunlar uiuc index Example: FULLMAX(lapc-config)#set Uplink_FEC_Code_Type 1 333 Updated Uplink_FEC_Code_Type for uiuc index 1 is 333 FULLMAX(lapc-config)#show Uplink_FEC_Code_Type 1 Uplink_FEC_Code_Type for uiuc index 1 is 0 Full Spectrum Confidential 78 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 ︳ ︳ Command FullMAX(lapc-config)# set Ranging_Data_Ratio FullMAX(lapc-config)# show Ranging_Data_Ratio Purpose The command sets the value of Ranging_Data_Ratio for the given index. The command shows the value of Ranging_Data_Ratio for the given index. Example: FULLMAX(lapc-config)#set Ranging_Data_Ratio 1 22 Updated Ranging_Data_Ratio for uiuc index 1 is 22 FULLMAX(lapc-config)#show Ranging_Data_Ratio 1 Ranging_Data_Ratio for uiuc index 1 is 19 ︳ ︳ ︳ ︳ Command FullMAX(lapc-config)# set Normalised_C_by_N_Mantis sa FullMAX(lapc-config)# show Normalised_C_by_N_Mantis sa Purpose The commnad sets the value of Normalised_C_by_N_Mantissa for the given index The commnad shows the value of Normalised_C_by_N_Mantissa for the given index Example: FULLMAX(lapc-config)#set Normalised_C_by_N_Mantissa 1 77 Updated Normalised_C_by_N_Mantissa for uiuc index 1 is 77 FULLMAX(lapc-config)#show Normalised_C_by_N_Mantissa 1 Normalised_C_by_N_Mantissa for uiuc index 1 is 60 ︳ ︳ ︳ ︳ Command FullMAX(lapc-config)# set Normalised_C_by_N_Expone nt FullMAX(lapc-config)# Purpose The command sets the value of Normalised_C_by_N_Exponent for the given index The command shows the value of Full Spectrum Confidential 79 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 show Normalised_C_by_N_Exponent for the given index Normalised_C_by_N_Expone nt Example: FULLMAX(lapc-config)#set Normalised_C_by_N_Exponent 1 1 Updated Normalised_C_by_N_Exponent for index 1 is 1 FULLMAX(lapc-config)#show Normalised_C_by_N_Exponent 1 Normalised_C_by_N_Exponent for index 1 is -1 ︳ ︳ ︳ Command Purpose FullMAX(lapc-config)# The command sets the value of set FIR_filter_coefficient_mantissa for the given index FIR_filter_coefficient_ma ntissa value FullMAX(lapc-config)# The command shows the value of show FIR_filter_coefficient_mantissa for the given FIR_filter_coefficient_ma index ntissa Example: FULLMAX(lapc-config)#set FIR_filter_coefficient_mantissa 1 65 Updated FIR_filter_coefficient_mantissa for index 1 is 65 FULLMAX(lapc-config)#show FIR_filter_coefficient_mantissa 1 FIR_filter_coefficient_mantissa for index 1 is 65 ︳ ︳ ︳ Command Purpose FullMAX(lapc-config)#set The command sets the value of FIR_filter_coefficient_TenP FIR_filter_coefficient_TenPwr for the given index. wr FullMAX(lapc-config)#show The command shows the value of FIR_filter_coefficient_TenP FIR_filter_coefficient_TenPwr for the given index. wr Example: FULLMAX(lapc-config)#set FIR_filter_coefficient_TenPwr 1 3 Updated FIR_filter_coefficient_TenPwr for index 1 is 3 FULLMAX(lapc-config)#show FIR_filter_coefficient_TenPwr 1 Full Spectrum Confidential 80 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FIR_filter_coefficient_TenPwr for index 1 is 3 ︳ ︳ ︳ ︳ Description Command FullMAX(lapc-config)#set Dl_Benchmark_Entry_Threshold_C INR FullMAX(lapc-config)#show Dl_Benchmark_Entry_Threshold_C INR Purpose Sets the value of Dl_Benchmark_Entry_Threshold_CINR for the given fec code and repetition . Displays the value of Dl_Benchmark_Entry_Threshold_CINR for the given fec code and repetition . Example: FULLMAX(lapc-config)#set Dl_Benchmark_Entry_Threshold_CINR 4 2 41e3 Updated Dl_Benchmark_Entry_Threshold_CINR for fec code and repition 2 is 41e3 FULLMAX(lapc-config)#show Dl_Benchmark_Entry_Threshold_CINR 4 2 Dl_Benchmark_Entry_Threshold_CINR for fec code 4 and repition 2 is 19e1 ︳ ︳ ︳ ︳ Description Command Purpose FullMAX(lapc-config)#set Sets the value of Dl_Benchmark_Exit_Threshold_CI Dl_Benchmark_Exit_Threshold_CINR for the NR given fec code and repetition . Displays the value of FullMAX(lapc-config)#show Dl_Benchmark_Exit_Threshold_CI Dl_Benchmark_Exit_Threshold_CINR for the given fec code and repetition . NR Example: FULLMAX(lapc-config)#set Dl_Benchmark_Exit_Threshold_CINR 4 2 41e3 Updated Dl_Benchmark_Exit_Threshold_CINR for fec code 4 and Full Spectrum Confidential 81 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 repition 2 is 41e3 FULLMAX(lapc-config)#show Dl_Benchmark_Exit_Threshold_CINR 4 2 Dl_Benchmark_Exit_Threshold_CINR for fec code 4 and repition 2 is 19e1 ︳ Command FullMAX(lapc-config)#set Ul_Benchmark_Entry_Threshold_C INR FullMAX(lapc-config)#show Ul_Benchmark_Entry_Threshold_C INR ︳ ︳ ︳ Purpose Sets the value of Ul_Benchmark_Entry_Threshold_CINR for the given fec code and repetition . Displays the value of Ul_Benchmark_Entry_Threshold_CINR for the given fec code and repetition . FULLMAX(lapc-config)#set Ul_Benchmark_Entry_Threshold_CINR 4 2 41e3 Updated Ul_Benchmark_Entry_Threshold_CINR for fec code and repition 2 is 41e3 FULLMAX(lapc-config)#show Ul_Benchmark_Entry_Threshold_CINR 4 2 Ul_Benchmark_Entry_Threshold_CINR for fec code 4 and repition 2 is 19e1 ︳ ︳ ︳ ︳ Description Command FullMAX(lapc-config)#set Ul_Benchmark_Exit_Threshold_CI NR FullMAX(lapc-config)#show Ul_Benchmark_Exit_Threshold_CI NR Purpose Sets the value of Ul_Benchmark_Exit_Threshold_CINR for the given fec code and repetition . Displays the value of Ul_Benchmark_Exit_Threshold_CINR for the given fec code and repetition . Example: Full Spectrum Confidential 82 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FULLMAX(lapc-config)#set Dl_Benchmark_Exit_Threshold_CINR 4 2 41e3 Updated Dl_Benchmark_Exit_Threshold_CINR for fec code 4 and repition 2 is 41e3 FULLMAX(lapc-config)#show Dl_Benchmark_Exit_Threshold_CINR 4 2 Dl_Benchmark_Exit_Threshold_CINR for fec code 4 and repition 2 is 19e1 ︳ ︳ ︳ Command FullMAX(lapc-config)#set Burst_Profile_evaluation_Timer FullMAX(lapc-config)#show Burst_Profile_evaluation_Timer Purpose The command sets the value of _Profile_evaluation_Timer The command shows the value of _Profile_evaluation_Timer Example: FULLMAX(lapc-config)#set Burst_Profile_evaluation_Timer 222 Updated Burst_Profile_evaluation_Timer: 250 FULLMAX(lapc-config)#show Burst_Profile_evaluation_Timer Burst_Profile_evaluation_Timer: 250 ︳ ︳ ︳ ︳ ︳ Description Command FullMAX(lapc-config)# set Mantissa_Lower_Thld_Rx_Power_Densi ty FullMAX(lapc-config)# show Mantissa_Lower_Thld_Rx_Power_Densi ty Purpose Sets the value of Mantissa_Lower_Thld_Rx_Power_Density Displays the value of Mantissa_Lower_Thld_Rx_Power_Density. Example: FULLMAX(lapc-config)#set Mantissa_Lower_Thld_Rx_Power_Density 22 Updated Mantissa_Lower_Thld_Rx_Power_Density -100 FULLMAX(lapc-config)#show Mantissa_Lower_Thld_Rx_Power_Density Mantissa_Lower_Thld_Rx_Power_Density -100 Full Spectrum Confidential 83 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 ︳ ︳ ︳ ︳ ︳ Description Command FullMAX(lapc-config)#set Mantissa_Higher_Thld_Rx_Power_Dens ity FullMAX(lapc-config)#show Mantissa_Higher_Thld_Rx_Power_Dens ity Purpose Sets the value of Mantissa_Higher_Thld_Rx_Power_Density to the given value. Display the value of Mantissa_Higher_Thld_Rx_Power_Density Example: FULLMAX(lapc-config)#set Mantissa_Higher_Thld_Rx_Power_Density 22 Updated Mantissa_Higher_Thld_Rx_Power_Density 22 FULLMAX(lapc-config)#show Mantissa_Higher_Thld_Rx_Power_Density Mantissa_Higher_Thld_Rx_Power_Density -60 ︳ ︳ ︳ ︳ Command FullMAX(lapc-config)#set Max_Length_Of_DLMAP_Mesg FullMAX(lapc-config)#show Max_Length_Of_DLMAP_Mesg Purpose The command sets the value of _Length_Of_DLMAP_Mesg to the value given The command shows the value of _Length_Of_DLMAP_Mesg Example: FULLMAX(lapc-config)#set Max_Length_Of_DLMAP_Mesg 22 Updated Max_Length_Of_DLMAP_Mesg: 22 FULLMAX(lapc-config)#show Max_Length_Of_DLMAP_Mesg Max_Length_Of_DLMAP_Mesg: 2 ︳ ︳ ︳ ︳ ︳ Command Purpose FullMAX(lapc-config)# set The command sets the value of Max_Aggregate_Length_Of_Control_M _Aggregate_Length_Of_Control_Messages to the essages given value. The command shows the value of FullMAX(lapc-config)# show Max_Aggregate_Length_Of_Control_M _Aggregate_Length_Of_Control_Messages. essages Full Spectrum Confidential 84 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Example: FULLMAX(lapc-config)#set Max_Aggregate_Length_Of_Control_Messages 22 Updated Max_Aggregate_Length_Of_Control_Messages: 22 FULLMAX(lapc-config)#show Max_Aggregate_Length_Of_Control_Messages Max_Length_Of_DLMAP_Mesg: 48 ︳ ︳ ︳ ︳ Command FullMAX(lapc-config)# set Max_No_Of_Slots_Used_For_Future_Al location_In_DL FullMAX(lapc-config)# show Max_No_Of_Slots_Used_For_Future_Al location_In_DL ︳ ︳ ︳ ︳ ︳ Purpose The command sets the value of _No_Of_Slots_Used_For_Future_Allocation_In_D L to the given value. The command shows the value of _No_Of_Slots_Used_For_Future_Allocation_In_D L. Example: [FULLMAX(lapc-config)]$set Max_No_Of_Slots_Used_For_Future_Allocation_In_DL 33 Updated Max_No_Of_Slots_Used_For_Future_Allocation_In_DL: 33 [FULLMAX(lapc-config)]$show Max_No_Of_Slots_Used_For_Future_Allocation_In_DL Max_Aggregate_Length_Of_Control_Messages: 90 ︳ ︳ Command FullMAX(lapc-config)# set Max_No_Of_Slots_Used_For_Future_Al location_In_UL FullMAX(lapc-config)# show Max_No_Of_Slots_Used_For_Future_Al location_In_UL ︳ ︳ ︳ ︳ ︳ ︳ ︳ Purpose The command sets the value of _No_Of_Slots_Used_For_Future_Allocation_In_U L to the given value. The command shows the value of _No_Of_Slots_Used_For_Future_Allocation_In_U L. Example: Full Spectrum Confidential 85 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FULLMAX(lapc-config)#set Max_No_Of_Slots_Used_For_Future_Allocation_In_UL 44 Updated Max_No_Of_Slots_Used_For_Future_Allocation_In_DL: 44 FULLMAX(lapc-config)#show Max_No_Of_Slots_Used_For_Future_Allocation_In_UL Max_No_Of_Slots_Used_For_Future_Allocation_In_DL: 10 ︳ ︳ ︳ ︳ ︳ ︳ ︳ ︳ ︳ ︳ ︳ ︳ ︳ Command Purpose FullMAX(lapc-config)#set The command sets the value of Max_No_Of_Slots_Can_Be_Used_For_C _No_Of_Slots_Can_Be_Used_For_CDMA_Alloca DMA_Allocation_In_Single_UL_Frame tion_In_Single_UL_Frame to the given value. FullMAX(lapc-config)#show The command shows the value of Max_No_Of_Slots_Can_Be_Used_For_C _No_Of_Slots_Can_Be_Used_For_CDMA_Alloca DMA_Allocation_In_Single_UL_Frame tion_In_Single_UL_Frame. Example: FULLMAX(lapc-config)#set Max_No_Of_Slots_Can_Be_Used_For_CDMA_Allocation_In_Single_U L_Frame 22 Updated Max_No_Of_Slots_Can_Be_Used_For_CDMA_Allocation_In_Single_U L_Frame: 22 FULLMAX(lapc-config)#show Max_No_Of_Slots_Can_Be_Used_For_CDMA_Allocation_In_Single_U L_Frame Max_No_Of_Slots_Used_For_Future_Allocation_In_DL: 10 ︳ ︳ ︳ ︳ Command Purpose FullMAX(lapc-config)# set The command sets the value of No_Of_CDMA_Ranging_Slots _Of_CDMA_Ranging_Slots to the given value. FullMAX(lapc-config)# show The command shows the value of No_Of_CDMA_Ranging_Slots _Of_CDMA_Ranging_Slots. FULLMAX(lapc-config)#set No_Of_CDMA_Ranging_Slots 33 Full Spectrum Confidential 86 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Updated No_Of_CDMA_Ranging_Slots: 33 FULLMAX(lapc-config)#show No_Of_CDMA_Ranging_Slots No_Of_CDMA_Ranging_Slots: 1 ︳ ︳ Command FullMAX(lapc-config)# set CDMA_Band_Width_Period FullMAX(lapc-config)# show CDMA_Band_Width_Period Purpose The command sets the value of CDMA_Band_Width_Period to the given value. The command shows the value of CDMA_Band_Width_Period FULLMAX(lapc-config)#set CDMA_Band_Width_Period 33 Updated CDMA_Band_Width_Period: 33 FULLMAX(lapc-config)#show CDMA_Band_Width_Period CDMA_Band_Width_Period: 6 ︳ ︳ ︳ ︳ ︳ Command Purpose FullMAX(lapc-config)# set The command sets the value of No_Of_CDMA_Band_Width_Slots _Of_CDMA_Band_Width_Slots to the given value FullMAX(lapc-config)# show The command shows the value of No_Of_CDMA_Band_Width_Slots _Of_CDMA_Band_Width_Slots Example: FULLMAX(lapc-config)#set No_Of_CDMA_Band_Width_Slots 33 Updated No_Of_CDMA_Band_Width_Slots: 33 FULLMAX(lapc-config)#show No_Of_CDMA_Band_Width_Slots No_Of_CDMA_Band_Width_Slots: 3 ︳ ︳ ︳ Command FullMAX(lapc-config)# set CDMA_Band_Width_Period FullMAX(lapc-config)# show CDMA_Band_Width_Period Purpose The command sets the value of _Band_Width_Period to the given value. The command shows the value of _Band_Width_Period. Example: FULLMAX(lapc-config)#set CDMA_Band_Width_Period 33 Full Spectrum Confidential 87 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Updated CDMA_Band_Width_Period: 33 FULLMAX(lapc-config)#show CDMA_Band_Width_Period CDMA_Band_Width_Period: 6 ︳ ︳ ︳ ︳ ︳ Command FullMAX(lapc-config)# set Max_Frame_Slots_Dl_Harq_Retransm ission FullMAX(lapc-config)# show Max_Frame_Slots_Dl_Harq_Retransm ission Purpose The command sets the value of _Frame_Slots_Dl_Harq_Retransmission to the given value. The command shows the value of _Frame_Slots_Dl_Harq_Retransmission. Example: FULLMAX(lapc-config)#set Max_Frame_Slots_Dl_Harq_Retransmission 33 Updated Max_Frame_Slots_Dl_Harq_Retransmission 33 FULLMAX(lapc-config)#show Max_Frame_Slots_Dl_Harq_Retransmission Max_Frame_Slots_Dl_Harq_Retransmission: 20 ︳ ︳ ︳ ︳ ︳ Command FullMAX(lapc-config)# set Max_Frame_Slots_Ul_Harq_Retransm ission FullMAX(lapc-config)# show Max_Frame_Slots_Ul_Harq_Retransm ission Purpose The command sets the value of Max_Frame_Slots_Ul_Harq_Retransmission to the given value. The command shows the value of _Frame_Slots_Ul_Harq_Retransmission. Example: FULLMAX(lapc-config)#set Max_Frame_Slots_Ul_Harq_Retransmission 33 Update Max_Frame_Slots_Ul_Harq_Retransmission: 33 FULLMAX(lapc-config)#show Max_Frame_Slots_Ul_Harq_Retransmission Max_Frame_Slots_Ul_Harq_Retransmission: 20 ︳ ︳ ︳ ︳ Full Spectrum Confidential 88 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Command FullMAX(lapc-config)# set Max_Ul_Harq_Ack_slots FullMAX(lapc-config)# show Max_Ul_Harq_Ack_slots Purpose The command sets the value of Max_Ul_Harq_Ack_slots to the givan value. The command shows the value of Max_Ul_Harq_Ack_slots Example: FULLMAX(lapc-config)#set Max_Ul_Harq_Ack_slots 24 Updated Max_Ul_Harq_Ack_slots: 24 FULLMAX(lapc-config)#show Max_Ul_Harq_Ack_slots Max_Ul_Harq_Ack_slots: 2 ︳ ︳ ︳ Command FullMAX(lapc-config)# set Initial_Ranging_Backoff_Start FullMAX(lapc-config)# show Initial_Ranging_Backoff_Start Purpose The command sets the value of _Ranging_Backoff_Start to the given value. The command shows the value of _Ranging_Backoff_Start Example: FULLMAX(lapc-config)#set Initial_Ranging_Backoff_Start 55 Updated Initial_Ranging_Backoff_Start: 55 FULLMAX(lapc-config)#show Initial_Ranging_Backoff_Start Initial_Ranging_Backoff_Start: 15 ︳ ︳ ︳ Command FullMAX(lapc-config)# set Initial_Ranging_Backoff_End FullMAX(lapc-config)# show Initial_Ranging_Backoff_End Purpose The command sets the value of _Ranging_Backoff_End to the given value. The command shows the value of _Ranging_Backoff_End. FULLMAX(lapc-config)#set Initial_Ranging_Backoff_End 44 Updated Initial_Ranging_Backoff_End: 44 FULLMAX(lapc-config)#show Initial_Ranging_Backoff_End Initial_Ranging_Backoff_End: 12 Full Spectrum Confidential 89 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 ︳ ︳ ︳ Command FullMAX(lapc-config)# set Bandwidth_Request_Backoff_Start FullMAX(lapc-config)# show Bandwidth_Request_Backoff_Start Purpose The command sets the value of _Request_Backoff_Start to the given value. The command shows the value of _Request_Backoff_Start. Example: FULLMAX(lapc-config)#set Bandwidth_Request_Backoff_Start 44 Updated Bandwidth_Request_Backoff_Start: 44 FULLMAX(lapc-config)#show Bandwidth_Request_Backoff_Start Bandwidth_Request_Backoff_Start: 3 ︳ ︳ ︳ Command FullMAX(lapc-config)# set Bandwidth_Request_Backoff_End FullMAX(lapc-config)# show Bandwidth_Request_Backoff_End Purpose The command sets the value _Request_Backoff_End to the given value. The command shows _Request_Backoff_End. the value Example: FULLMAX(lapc-config)#set Bandwidth_Request_Backoff_End 55 Updated Bandwidth_Request_Backoff_End: 55 FULLMAX(lapc-config)#show Bandwidth_Request_Backoff_End Bandwidth_Request_Backoff_End: 2 ︳ ︳ ︳ Command FullMAX(lapc-config)# set Percentage_Of_Reserved_Symbols FullMAX(lapc-config)# show Percentage_Of_Reserved_Symbols Purpose The command sets the value of _Of_Reserved_Symbols to the given value. The command shows the value of _Of_Reserved_Symbols. Example: Full Spectrum Confidential 90 of of FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FULLMAX(lapc-config)#set Percentage_Of_Reserved_Symbols 99 Updated Percentage_Of_Reserved_Symbols: 99 ︳ ︳ ︳ ︳ ︳ FULLMAX(lapc-config)#show Percentage_Of_Reserved_Symbols Percentage_Of_Reserved_Symbols: 10 Command Purpose The command sets the value of FullMAX(lapc-config)# set Percentags_Of_Head_Room_For_MAC _Of_Head_Room_For_MAC to the given value. FullMAX(lapc-config)# show The command shows the value of Percentags_Of_Head_Room_For_MAC _Of_Head_Room_For_MAC. Example: FULLMAX(lapc-config)#set Percentags_Of_Head_Room_For_MAC 88 Updated Percentags_Of_Head_Room_For_MAC: 88 FULLMAX(lapc-config)#show Percentags_Of_Head_Room_For_MAC Percentags_Of_Head_Room_For_MAC: 10 4.3 FS4000 and MS4000 Operation The FullMAX MS CLI supports the following commands. The access to this commands are based on the user privileges. The Admin has the privilege to control and monitor all the information supported by the FullMAX MS CLI commands, where as the operator has limited privileges. After the successful authentication, the user gets the access permission to the command line interface. Based on the user privileges, the help menu will be displayed to the user. 4.3.1 Main Group When user logs in to the CLI it will lock to the default group which is the main group.When ever the user enters the Main group,CLI will display the main prompt .Help command in main group will show the commands supported in main group along with the group lock commands. Only commands related to main group can be executed in main group. FullMAX# main group System IP address. Command FullMAX# set ip-address Purpose Updates the system IP Full Spectrum Confidential Privileges A/O 91 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX# show ipaddress address. Displays the system IP address. A/O Example: FullMAX#set ip-address 10.60.4.42 Updated IP address: 10.60.4.42 FullMAX# show ip-address IP address: 10.60.4.56 4.3.2 ss-config The ms-config group define the commands that monitors or updates the configuration information. The user upon entering the ms-config command locks into the CLI to execute commands only related to MS configuration. FullMAX# FullMAX# ss-config FullMAX(ss-config)# Command FullMAX# ss-config Purpose The command allows the user to lock into the group ss-config and execute all the commands related to the group. Privileges A/O The commands supported by the ss-config group are. Time since last received DL-MAP message before downlink synchronization is considered lost in ms. Command FullMAX(ss-config)# set lost-dl-map-interval FullMAX(ss-config)# show lost-dl-map-interval Purpose Privileges The command allows the user to update A timer value since last received DLMAP message before downlink synchronization is considered lost. The command allows the user to A/O display the timer value since last received DL-MAP message before downlink synchronization is considered lost. Full Spectrum Confidential 92 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Example: FullMAX(ss-config) # set lost-dl-map-interval 300 Updated lost-dl-map-interval 300 milliseconds FullMAX (ss-config) # show lost-dl-map-interval lost-dl-map-interval 300 milliseconds Time since last received UL-MAP message before downlink synchronization is considered lost in ms. Command FullMAX(ss-config)# set lost-ul-map-interval FullMAX(ss-config)# show lost-ul-map-interval Purpose The command allows the user to update timer value since last received UL-MAP message before downlink synchronization is considered lost. The command allows the user to display the timer value since last received ULMAP message before downlink synchronization is considered lost. Privileges A/O Example: FullMAX(ss-config)# set lost-ul-map-interval 300 Updated lost-ul-map-interval 300 milliseconds FullMAX(ss-config)# show lost-ul-map-interval lost-ul-map-interval 300 milliseconds Number of retries on contention ranging requests. Command FullMAX(ss-config)# set contention-rng-retries FullMAX(ss-config)#show contention-rng-retries Purpose The command allows the user to update the contention ranging retries parameter. Privileges The command allows the user to display the contention ranging retries parameter. A/O Example: FullMAX(ss-config)# set contention-rng-retries 20 Updated contention-rng-retries 20 FullMAX(ss-config)# show contention-rng-retries contention-rng-retries 20 Full Spectrum Confidential 93 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Number of retries on bandwidth allocation request. Command FullMAX(ss-config)# set request-retries FullMAX(ss-config)# show request-retries Purpose Privileges The command allows the user to update the number of retries on bandwidth allocation request. The command allows the user to A/O display the number of retries on bandwidth allocation request. Example: FullMAX(ss-config)# set request-retries 88 Updated request-retries 88 FullMAX(ss-config)# show request-retries request-retries 88 Number of retries on registration request. Command FullMAX(ss-config)# set reg-requset-retries FullMAX(ss-config)# show reg-requset-retries Purpose The command allows the user to update the number of retries on registration request. The command allows the user to display the number of retries on registration request. Privileges A/O Example: FullMAX(ss-config)# set reg-requset-retries 8 Updated reg-requset-retries 8 FullMAX(ss-config)# show reg-requset-retries reg-requset-retries 8 Wait for DCD timeout in milliseconds. Command FullMAX(ss-config)# set t1-timeout FullMAX(ss-config)# show t1-timeout Purpose The command allows the user to update the DCD timeout parameter. The command allows the user to display the DCD timeout parameter. Full Spectrum Confidential Privileges A/O 94 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Example: FullMAX(ss-config)# set t1-timeout 9000 Updated t1-timeout 9000 milliseconds. FullMAX(ss-config)# show t1-timeout t1-timeout 9000 milliseconds. Wait for broadcast ranging timeout in milliseconds. Command FullMAX(ss-config)# set t2-timeout FullMAX(ss-config)# show t2-timeout Purpose Privileges The command allows the user to update A the broadcast ranging timeout parameter The command allows the user to A/O display the broadcast ranging timeout parameter Example: FullMAX(ss-config) # set t2-timeout 8000 Updated t2-timeout 8000 milliseconds. FullMAX(ss-config)# show t2-timeout t2-timeout 8000 milliseconds. Ranging response reception timeout following the transmission of Ranging Request in milliseconds. Command FullMAX(ss-config)# set t3-timeout FullMAX(ss-config)# show t3-timeout Purpose Privileges The command allows the user to update A the ranging response timeout parameter. The command allows the user to A/O display the ranging response timeout parameter. Example: FullMAX(ss-config)# set t3-timeout 45 Updated t3-timeout 45 milliseconds. FullMAX(ss-config)# show t3-timeout T3-timeout 45 milliseconds. Full Spectrum Confidential 95 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Wait for ranging opportunity or data grant. If pending until complete field was used earlier by this SS, then the value of that field shall be added to this interval in second. Command FullMAX(ss-config)# set t4-timeout FullMAX(ss-config)# show t4-timeout Purpose The command allows the user to update the wait for ranging opportunity timeout parameter. The command allows the user to display the wait for ranging opportunity timeout parameter. Privileges A/O Example: FullMAX(ss-config) # set t4-timeout 45 Updated t4-timeout 45 milliseconds. FullMAX(ss-config)# show t4-timeout T4-timeout 45 milliseconds. Wait for Registration Response in milliseconds. Command FullMAX(ss-config)#set t16-timeout FullMAX (ss-config)#show t16-timeout Purpose Privileges The command allows the user to update the Registration response wait timer. The command allows the user to A/O display the Registration response wait timer. Example: FullMAX(ss-config)#set t16-timeout 540 Updated t16-timeout 540 milliseconds. FullMAX (ss-config) # show t16-timeout T16-timeout 540 milliseconds. Wait for UCD descriptor in milliseconds. Command FullMAX(ss-config)# set t12-timeout FullMAX(ss-config)# show Purpose The command allows the user to update wait for UCD descriptor timer. The command allows the user to Full Spectrum Confidential Privileges A/O 96 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 display the wait for UCD descriptor timer. t12-timeout Example: FullMAX(ss-config) # set t12-timeout 12000 Updated t12-timeout 12000 milliseconds. FullMAX (ss-config) # show t12-timeout t12-timeout 12000 milliseconds. Wait for SBC-RSP timeout in milliseconds. Command FullMAX(ss-config)# set t18-timeout FullMAX(ss-config)# show t18-timeout Purpose The command allows the user to update wait for SBC-RSP timeout parameter. The command allows the user to display the wait for SBC-RSP timeout parameter. Privileges A/O Example: FullMAX(ss-config) # set t18-timeout 7000 Updated t18-timeout 7000 milliseconds. FullMAX (ss-config) # show t18-timeout t18-timeout 7000 milliseconds. Time DL-channel remains unusable in ms. Command FullMAX(ss-config)#set t19-timeout FullMAX(ss-config)#show t19-timeout Purpose Privileges The command allows the user to update time for DL-channel remains unusable in ms.. The command allows the user to A/O display the time for DL-channel remains unusable in ms. Example: FullMAX(ss-config)# set t19-timeout 7000 Updated t19-timeout 7000 milliseconds. FullMAX(ss-config)# show t19-timeout t19-timeout 7000 milliseconds. Full Spectrum Confidential 97 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Time SS searches for preambles on a given channel in milliseconds. Command FullMAX(ss-config)#set t20-timeout FullMAX(ss-config)#show t20-timeout Purpose The command allows the user to update the time to search for preambles on a given channel. The command allows the user to display time to search for preambles on a given channel. Privileges A/O Example: FullMAX(ss-config) # set t20-timeout 600 Updated t20-timeout 600 milliseconds. FullMAX (ss-config) # show t20-timeout t20-timeout 600 milliseconds. Time SS searches for DL-MAP on a given channel in milliseconds. Command FullMAX(ss-config)#set t21-timeout FullMAX(ss-config)#show t21-timeout Purpose The command allows the user to update the time to search for DL-MAP on a given channel. The command allows the user to display time to search for DL-MAP on a given channel. Privileges A/O Example: FullMAX(ss-config)# set t21-timeout 1200 Updated t21-timeout 1200 milliseconds. FullMAX(ss-config)# show t21-timeout t21-timeout 1200 milliseconds. 4.3.3 device The device group define the commands that monitors or updates the device related information in the private MIB. The user upon entering the device command locks into the CLI to execute commands only related to device. FullMAX# FullMAX# device Full Spectrum Confidential 98 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(device)# Command FullMAX# Purpose The command allows the user to lock into the group device and execute all the commands related to the group. Privileges A/O Type of the device (BS / MS / SS). Command FullMAX(device)#show type Purpose The command allows the user display the device type (BS/MS/SS) Privileges A/O Example: FullMAX(device)# show type type SS The geographical position of the device , i.e. the real number describing the longitude and latitusde encoded as a printable string. Longitude - the precision is within the range -90..90 degrees.Positive numbers indicate locations north of the equator. Latitude - The precision is within the range -180..180 degrees.Positive numbers indicate locations east of the prime meridian Command FullMAX(device)#set gpos FullMAX(device)#show gpos Purpose The command allows the user to send the command to the GPS avaliable on the system. The command allows the user display geographical position of the device. Privileges A/O Example: FullMAX(device)# set gpos 64.000 88.3400 updated gpos 64.000 88.3400 FullMAX(device)# show gpos gpos 64.000 88.3400 The absolute time of last device boot up. Command Purpose Full Spectrum Confidential Privileges 99 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(device)# show boot- timeThe command allows the user display the device boot up time. A/O Example: FullMAX(device)# show boot-time boot-time 230404:18052008 Setting this object to TRUE causes the device to write all configuration changes in FLASH memory. On next boot the changes will be relevant. If this operation does not occur, configuration changes will not be maintained through reset Reading this object always returns FALSE Command FullMAX(device)#set commit-save FullMAX(device)#show commit-save Purpose The command allows the user to set the value to TRUE so as to save the configuration changes in FLASH. The command allows the user display the device commit-save Privileges A/O Example: FullMAX(device)# set commit-save commit-save TRUE FullMAX(device)# show commit-save commit-save FALSE GPS card availability in the device. Command FullMAX(device)#show gps-card Purpose The command allows the user display the availability of GPS card in the device. Privileges A/O Example: FullMAX(device)# show gps-card gps-card YES Hardware version of baseband processor card. Command FullMAX(device)#show bpc-hw-version Purpose The command allows the user display the hardware version of baseband processor card. Full Spectrum Confidential Privileges A/O 100 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Example: FullMAX(device)# show bpc-hw-version bpc-hw-version 1.10 Hardware version of the Analog Front End (AFE) Command FullMAX(device)#show afe-hw-ver Purpose The command allows the user display the hardware version of AFE. Privileges A/O Example: FullMAX(device)# show afe-hw-ver device-afe-hw-version 1.3 Software version of the Analog Front End (AFE) Command FullMAX(device)#show afe-sw-ver Purpose The command allows the user display the software version of AFE. Privileges A/O Example: FullMAX(device)# show afe-sw-ver device-afe-sw-version 1.3 Software version of the device general embedded software. Command FullMAX(device)#show build-sw-ver Purpose The command allows the user display the software version of the software build Privileges A/O Example: FullMAX(device)#show build-sw-ver build-sw-version Full Spectrum Confidential 101 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 4.3.4 Measurements The Measurement group define the commands that monitors or updates the measurement related information in the private MIB. The user upon entering the device command locks into the CLI to execute commands only related to Measurement. FullMAX# FullMAX# measurement FullMAX(measurement)# Command FullMAX# Purpose The command allows the user to lock into the group Measurement and execute all the commands related to this group. Privileges A/O Command FullMAX(measurement)# show temperature Purpose The command allows the user display temperature of the device. Privileges A/O FullMAX(measurement)# track [-rN][-iN] temperature The command allows the user to display real time temperature sample of the device. A/O measurement Temperature degree in Celsius Example: FullMAX(measurement)# show temperature Temperature 45 degrees-Celsius FullMAX(measurement)# track –r3 –i2 temperature Temperature 45 degrees-Celsius Temperature 46 degrees-Celsius Temperature 45 degrees-Celsius Voltage measurement Command FullMAX(measurement)# show voltage Purpose The command allows the user display voltage of the device. Privileges A/O FullMAX(measurement)# track [-rN][-iN] voltage The command allows the user to display multiple voltage samples of the device. A/O Example: FullMAX(measurement)# show voltage Voltage 3 volts Full Spectrum Confidential 102 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(measurement)# track –r3 –i10 voltage Voltage 3 volts Voltage 3 volts Voltage 3 volts Current measurements Command FullMAX(measurement)#show current FullMAX(measurement)#track [-rN][-iN] current. Purpose The command allows the user display the current in the device. Privileges A/O The command allows the user to display multiple current measurements in the device A/O Example: FullMAX(measurement)# show current Current 2 amp FullMAX(measurement)# track –r4 current Current 2 amp Current 2 amp Current 2 amp Transmit power Command FullMAX(measurement)#show tx-power FullMAX(measurement #track [-rN][-iN] tx-power Purpose The command allows the user display the transmit power. The command allows the user to display multple transmit power measurements. Privileges A/O A/O Example: FullMAX(measurement)# show tx-power Tx-power 45 dBm FullMAX(measurement)# track –r2 tx-power Tx-power 45 dBm Tx-power 43 dBm Receive power Full Spectrum Confidential 103 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Command FullMAX(measurement)#show rx-power FullMAX(measurement)#track [-rN][-iN] rx-power Purpose The command allows the user display the receive power. The command allows the user to display multiple receive power measurements. Privileges A/O A/O Example: FullMAX(measurement)# show rx-power rx-power 45 dBm FullMAX(measurement)# track –r2 -i2 rx-power rx-power 45 dBm rx-power 45 dBm Read the temperature from the Analog Front End. Command FullMAX(measurement)#show afe-temperature FullMAX(measurement)#track [-rN][-iN] afe-temperature Purpose The command allows the user display temperatue from Analog Front End. The command allows the user to display multiple temperatue measurements from Analog Front End Privileges A/O. A/O Example: FullMAX(measurement)# show afe-temperatue afe-temperature 27 celcius FullMAX(measurement)# track -r4 -i30 afe-temperatue afe-temperature 27 celcius afe-temperature 27 celcius afe-temperature 27 celcius afe-temperature 27 celcius Read the Receive Signal Strength Indicator (RSSI) from the Analog Front End. Command Purpose FullMAX(measurement)#show The command allows the user display afe-rssi RSSI from Analog Front End. FullMAX(measurement)#track The command allows the user to [-rN][-iN] afe-rssi display multiple RSSI measurements from Analog Front End . Privileges A/O A/O Example: FullMAX(measurement)# show afe-rssi Full Spectrum Confidential 104 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 afe-rssi 80 dBm FullMAX(measurement)# track -r4 -i30 afe-rssi afe-rssi 80 dBm afe-rssi 80 dBm afe-rssi 80 dBm afe-rssi 80 dBm 4.3.5 ss-private The bs-private group define the commands that monitors or updates the private mib related information. The user upon entering the ss-private command locks into the CLI to execute commands only related to BS private mib. FullMAX# FullMAX# ss-private FullMAX(ss-private)# Command FullMAX# ss-private Purpose The command allows the user to lock into the group ss-private and execute all the commands related to the group. Privileges A/O This table contains statistical information that can be used to characterize the adaptive modulation and coding performance in the uplink. Command FullMAX(ss-private)#show ss-rx-amc-count-table Purpose This command shows all the parameters and their values for RxAmcCountTable.. Privileges A/O Example: FullMAX(ss-private)# show ss-rx-amc-count-table 1 ss-rx-octets for diuc-index 1 is 0 ss-rx-packets for diuc-index 1 is 0 ss-tx-erroredpackets for diuc-index 1 is 0 The Downlink Interval Usage Code indicates the uplink burst profile in the UCD message. Command FullMAX(ss-private)# show ss-rx-diuc-index Example: FullMAX(ss-private)# show Purpose Privileges This command allows the users to A/O display the avaliable diuc-index ss-rx-diuc-index Full Spectrum Confidential 105 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 ss-ul-diuc-index: ss-ul-diuc-index: ss-ul-diuc-index: ss-ul-diuc-index: ss-ul-diuc-index: ss-ul-diuc-index: ss-ul-diuc-index: ss-ul-diuc-index: ss-ul-diuc-index: ss-ul-diuc-index: 10 This object counts the number of octets received in the downlink using the downlink burst profile indexed by diuc-index. Command FullMAX(ss-private)#show ss-rx-octets Purpose Privileges This command allows the user to display the number of octets received in DL burst profile indexed by diuc-index. A/O Example: FullMAX(ss-private)# show ss-rx-octets 1 ss-rx-octets for diuc-index 1 is 0 This object counts the number of packets received in the downlink using the downlink burst profile indexed by Command FullMAX(ss-private)#show ss-rx-packets Purpose This Command allows the user to display the number of packets received in DL burst profile indexed by diuc-index Privileges A/O Example: FullMAX(ss-private)#show ss-rx-packets 1 ss-rx-packets for diuc-index 1 is 0 Command FullMAX(ss-private)#show ss-rx-erroredPackets Purpose This command allows the use rto display the number of errored packets indexed by diuc-index Privileges A/O Example: FullMAX(ss-private)# show ss-rx-erroredPackets 1 Full Spectrum Confidential 106 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 ss-tx-errored packets for uiuc index 1 is 0 This table contains statistical information that can be used to characterize the adaptive modulation and coding performance in the downlink. Command FullMAX(ss-private)#show ss-tx-amc-count-table Purpose This command allows the user to display the parametes and values of the TxAmcCount Table. Privileges A/O Example: FullMAX(ss-private)# show ss-tx-amc-count-table 1 ss-tx-octets for uiuc-index 1 is 0 ss-tx-packets for uiuc-index 1 is 0 The Uplink Interval Usage Code indicates the uplink burst profile in the UCD message. Command FullMAX(ss-private)# show ss-tx-uiuc-index Purpose This command allows the user to display avaliable uiuc- indices Privileges A/O Example: FullMAX(ss-private)# show ss-tx-uiuc-index ss-dl-uiuc-index: 0 ss-dl-uiuc-index: 1 ss-dl-uiuc-index: 2 ss-dl-uiuc-index: 3 ss-dl-uiuc-index: 4 ss-dl-uiuc-index: 5 ss-dl-uiuc-index: 6 ss-dl-uiuc-index: 7 ss-dl-uiuc-index: 8 ss-dl-uiuc-index: 9 ss-dl-uiuc-index: 10 ss-dl-uiuc-index: 11 ss-dl-uiuc-index: 12 This object counts the number of octets transmitted in the uplink using the uplink burst profile indexed by uiuc-index Command FullMAX(ss-private)#show ss-tx-octets Purpose This command allows the user to display the Octets indexed by Full Spectrum Confidential Privileges A/O 107 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 uiuc-index. Example: FullMAX(ss-private)# show ss-tx-octets 1 ss-tx-octets for uiuc-index 1 is 0 This object counts the number of packets transmitted in the uplink using the uplink burst profile indexed by uiuc-index . Command FullMAX(ss-private)#show ss-tx-packets Purpose This command allows the user to display the packets in UL burst indexed by uiuc-index Privileges A/O Example: FullMAX(ss-private)# show ss-tx-packets 1 ss-tx-packets for uiuc-index 1 is 0 This Table measures service flow traffic Command FullMAX(ss-private)# show cmn-sf-table Purpose This command allows the user to display the parameters and values for cmn-sf-table for this SFID Privileges A/O Example: FullMAX(ss-private)#show cmn-sf-table 2001 sf-total-octets for sfid 2001 is 0 sf-total-pkts for sfid 2001 is 0 sf-errored-pkts for sfid 2001 is 0 sf-frag-orig for sfid 2001 is 0 sf-frag-total for sfid 2001 is 0 sf-missing-frag for sfid 2001 is 0 Command FullMAX(ss-private)#show cmn-pm-sfid Purpose This command allows the user to display the avlaibale SFID. Privileges A/O Example: FullMAX(ss-private)# show cmn-pm-sfid cmn-pm-sfid 2001 Full Spectrum Confidential 108 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 cmn-pm-sfid 2002 cmn-pm-sfid 3000 This determines the total octets received/transmitted on this service flow. Command FullMAX(ss-private)#show sf-total-octets Purpose Privileges This command allows the user to diplay A/O the total octets received or transmitted for this service-flow. Example: FullMAX(ss-private)# show sf-total-octets 2001 sf-total-octets for sfid (2001) : 1000 This determines the total number of packets received /transmitted on this service flow. Command FullMAX(ss-private)#show sf-total-pkts Purpose This Command allows the user to display the total packets received or trasmitted for this service-flow Privileges A/O Example: FullMAX(bs-private)#show sf-total-pkts 2001 sf-total-pkts for sfid (2001): 22 This determines number of packets that were dropped due to missing fragments / bad ARQ blocks. Command FullMAX(ss-private)#show sf-errored-pkts Purpose This Command Allows the user to display the total errored packets received or transmitted for this service flow. Privileges A/O Example: FullMAX(ss-private)# show sf-errored-pkts 2001 sf-errored-pkts for sfid (2001): 1 This determines number of fragments / ARQ blocks originally transmitted/received on this service flow. Full Spectrum Confidential 109 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Command FullMAX(ss-private)# show sf-frag-orig Purpose This Command allows the user to display the total fragments received or transmitted originally on this service flow. Privileges A/O Example: FullMAX(ss-private)# show sf-frag-orig 2001 sf-frag-orig for sfid (2001) : 2 This determines total fragments / ARQ blocks transmitted / received on this service flow. Command FullMAX(ss-private)# show sf-frag-total Purpose This Command allows the user to display the total fragments received or transmitted on this service flow. 2001 Example: FullMAX(ss-private)# show sf-frag-total sf-frag-total for sfid (2001): 2 Privileges A/O Description This determines the number of missing received fragments received or NACK. Command FullMAX(ss-private)# show sf-missing-frag Purpose This command allows the user to display the number of missing received fragments or NACK. Privileges A/O Example: FullMAX(ss-private)# show sf-missing-frag 2001 sf-missing-frag for sfid (2001): 1 4.3.6 ss-chconfig The ss-chconfig group define the commands that monitors or updates the channel config MIB related information. The user upon entering(locking) the ss-chconfig group can execute commands only related to ss-chconfig group. FullMAX# Full Spectrum Confidential 110 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX# ss-chconfig FullMAX(ss-chconfig)# Command FullMAX#ss-chconfig Purpose The command allows the user to lock into the group ss-chconfig and execute all the commands related to the group. Privileges A/O Each entry in the table contains optional channels configuration. A table can include a single active channel configuration and some inactive channel configurations A MS when searching for a new BS will scan the table for available channels. Command FullMAX(ss-chconfig)#show ss-channel-config-table Purpose The command allows the user display the channel configuration based on index. A/O Privileges A/O Example: FullMAX(ss-chconfig)# show channel-config-table 1 center-channel-frequency for chn-index 1 is 12000 Hz center-bandwidth for chn-index 1 is 120 Hz center-config-status for chn-index 1 is ACTIVE Index in channel-config-table. Command FullMAX(ss-chconfig)# show channel-config-index Purpose Privileges The command allows the user display A/O all the channel configuration indices Example: FullMAX(ss-chconfig)# show channel-config-index Channel-config-index 1 Channel-config-index 2 sets an optional center frequency for the transmitter and receiver Units are in Hz Command FullMAX(ss-chconfig)# show center-channel-frequency Example: Purpose Privileges The command allows the user display A/O center frequencies for the given index. Full Spectrum Confidential 111 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(ss-chconfig)# show center-channel-frequency 1 center-channel-frequency for chn-index 1 16000 Hz sets the bandwidth of the channel in the associated center frequency Units are in Hz. Command FullMAX(ss-chconfig)#show center-bandwidth Purpose Privileges The command allows the user display A/O bandwidth for the given index. Example: FullMAX(ss-chconfig)# show center-bandwidth 2 center-bandwidth for chn-index 2 is 1600 Hz The channel sampling clock Command FullMAX(ss-chconfig)#show sampling-clock Purpose Privileges The command allows the user display A/O sampling clock time for the given index. Example: FullMAX(ss-chconfig)# show sampling-clock 2 sampling-clock for chn-index 2 is 16 The ID of the PHY filter to use for this channel. Command FullMAX(ss-chconfig)#show filter-id Purpose Privileges The command allows the user display A/O filter id for the given index. Example: FullMAX(ss-chconfig)# show filter-id 2 filter-id for chn-index 2 is 16 Indicates the current state of this entry inactiveOption(0) - indicates that this entry is a scanning option that is not currently in use. currentActive(1) - indicates that this entry is the current channel channel configuration Full Spectrum Confidential 112 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 Command FullMAX(ss-chconfig)#show channel-config-status Purpose The command allows the user display the current status for the given index Privileges A/O Example: FullMAX(ss-chconfig)# show channel-config-status 2 channel-config-status for chn-index 2 is ACTIVE This determines the row status of the Channel config table for this config-index. Command FullMAX(ss-chconfig)#show channel-row-status Purpose The command allows the user display the row status for the given index Privileges A/O Example: FullMAX(ss-chconfig)# show channel-row-status 2 channel-row-status for chn-index 2 is ACTIVE 4.3.7 ss-trap The trap-ctrl-register group defines the commands that monitors or updates the trap mib related information. The user upon entering the trap-ctrl-register command locks into the CLI to execute commands only related to BS and MS trap control register mib. FullMAX# FullMAX# ss-trap FullMAX (ss-trap) # Command FullMAX# ss-trap Purpose The command allows the user to lock into the group ss-trap and execute all the commands related to the group Privileges A/O Within this group we can get the following parameters. SstrapControlRegister PriTrapControlRegister. The parameter is used to enable or disable the SS traps. Command FullMAX(ss-trap)# set sstrap-control-register (enable or disable) Purpose The command allows the user to enable or disable the SS traps Full Spectrum Confidential Privileges 113 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 FullMAX(ss-trap)#show sstrap-control-register The command allows the user display the enable or disable status of the SS traps. A/O Example: FullMAX(ss-trap)# set ss-trap-control-register 0 Updated ss-trap-control-register 0 (disable) FullMAX(ss-trap)# show ss-trap-control-register ss-trap-control-register 0 (disable) Low Rssi threshold for generating the RSSI alarm trap. Command FullMAX(ss-trap)# set rssi-low-threshold FullMAX(ss-trap)#show rssi-low-threshold Purpose The command allows the user to update the lower threshold for generating RSSI alaram trap The command allows the user to display the lower threshold for generating RSSI alaram trap Privileges A/O Example: FullMAX(ss-trap)# set rssi-low-threshold 34 Updated rssi-low-threshold 34 dBm FullMAX(ss-trap)# show rssi-low-threshold rssi-low-threshold 34 dBm High Rssi threshold for generating the RSSI alarm trap. Command Purpose Privileges FullMAX(ss-trap)# set The command allows the user to update A rssi-high-threshold the higher threshold for generating RSSI alaram trap FullMAX(ss-trap)# show The command allows the user to A/O rssi-high-threshold display the higher threshold for generating RSSI alaram trap. Example: FullMAX(ss-trap)# set rssi-high-threshold 34 Updated rssi-high-threshold 54 dBm FullMAX(ss-trap)# show rssi-high-threshold rssi-high-threshold 54 dBm Full Spectrum Confidential 114 FullMAX BS1000, FS4000 and MS4000 User Manual Version 1.3 -trap-ctrl The object is used to enable or disable Base Station traps From left to right, the set bit indicates the corresponding Base Station trap is enabled. { wmanPriPowerStatusChange (0), wmanPriFanStatusChange (1), wmanPriTemperatureChange (2), wmanPriConfigChange (3), wmanPriAfeBitError (4) } Command FullMAX(ss-trap)#set private-trap-ctrl FullMAX(ss-trap)#show private-trap-ctrl Purpose This command allows the user to display the value of the private trap control This command allows the user to display the value of the private trap control Privileges A/O Example: FullMAX(ss-trap)# set private-trap-ctrl 21 updated private-trap-ctrl { wmanPriPowerStatusChange(0), wmanPriPowerStatusChange(2), wmanPriPowerStatusChange(4)} FullMAX(ss-trap)# show private-trap-ctrl private-trap-ctl enabled { wmanPriPowerStatusChange(0), wmanPriPowerStatusChange(2), wmanPriPowerStatusChange (4)} Full Spectrum Confidential 115
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : stkan_000 Create Date : 2013:11:19 14:14:10-08:00 Modify Date : 2013:11:19 14:14:10-08:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Format : application/pdf Title : Microsoft Word - FullMax User Manual V1.3 Creator : stkan_000 Creator Tool : PScript5.dll Version 5.2.2 Producer : Acrobat Distiller 9.0.0 (Windows) Document ID : uuid:61447f15-4bdc-436f-9432-cd6c68eadf7c Instance ID : uuid:fccf2889-c82a-4d28-bad0-475a3d746617 Page Count : 115EXIF Metadata provided by EXIF.tools