OpenVox Communication V100-PTMC Transcoding Cards User Manual V100 ptmc Hardware Install

OpenVox Communication Co., Ltd. Transcoding Cards V100 ptmc Hardware Install

Manual

  Hardware installation Manual   OpenVox Communication Co. Limited.   URL: www.openvox.cn   Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049  1  深圳开源通信有限公司  OpenVox-Best Cost Effective Asterisk Cards      OpenVox V100_PTMC hardware installation Manual     Written by: Carson Wang     Date: 11/24/2011 Version:1.00      深圳开源通信有限公司
  Hardware installation Manual   OpenVox Communication Co. Limited.   URL: www.openvox.cn   Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049  2 OpenVox-Best Cost Effective Asterisk Cards        OpenVox Communication Co. Ltd.Addr: F/3, Building 127, Jindi industrial zone, Futian district, Shenzhen, Guangdong, China 518048,ChinaTel:+86-755-83460576,Fax:+86-755-83460491E-Mail:sales@openvox.com.cn support@openvox.com.cnIM for Sales:   miaolin71@hotmail.com Business Hours: 9:30AM-17:30PM from Monday-FridayURL:openvox.com.cn  Thank You for Choosing OpenVox Products!
  Hardware installation Manual   OpenVox Communication Co. Limited.   URL: www.openvox.cn   Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049  3Copyright Copyright© 2011 OpenVox Inc. All rights reserved. No part of this document may be reproduced without prior written permission. Confidentiality Information contained herein is of a highly sensitive nature and is confidential and proprietary to OpenVox Inc. No part may be distributed, reproduced or disclosed orally or in written form to any party other than the direct recipients without the express written consent of OpenVox Inc. Disclaimer OpenVox Inc. reserves the right to modify the design, characteristics, and products at any time without notification or obligation and shall not be held liable for any error or damage of any kind resulting from the use of this document. OpenVox has made every effort to ensure that the information contained in this document is accurate and complete; however, the contents of this document are subject to revision without notice. Contact OpenVox to ensure you have the latest revision of this document. Trademarks All other trademarks mentioned in this document are the property of their respective owners.   EMC (pending) FCC Part 15 Class B EN55022 Class B EN55024                  General Safety Instructions     WARNING The PxCC that have V100_PTMC card installed must comply with        the country specific safety regulations.        WARNING        Only service personnel should install V100_PTMC card.        WARNING        Before you install V100_PTMC card or remove the cover from your PMC carrier, Unplug the power cord from the computer.               WARNING        For avoiding personal injuries and damage to your computer,and
  Hardware installation Manual   OpenVox Communication Co. Limited.   URL: www.openvox.cn   Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049  4       V100_PTMC card, make sure the card’bezel is secured to the PMC carrier ’s Chassis ground by fastening the card with the screw.        WARNING        Electrical Surges,ESD are very destructive to the equipment.        To avoid it,make sure there is a low impedance discharge path        from your computer to Chassis ground.        WARNING        To reduce the risk of damage or injury,follow all steps or procedures as instructed.          Release History Vesrsion  Date  Changes  Editor 1.0O  11/24/2011  First preliminary release. Carson Wang
  Hardware installation Manual   OpenVox Communication Co. Limited.   URL: www.openvox.cn   Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049  5 Contents  Conventions  About This manunnal  Chapter 1 Overview   Overview     Feature      Codec Support     Target Applications Dimensions Interface Power Requirments Operating Temperature Range Humidity Hardware and Software Requirement  Chapter 2 Hardware Architecture Introduction Vocallo DSP and core module Giga NIC     Front panel RJ45     P4 in PTMC connectors PTMC connectors     Glue  Dip Switch LED indicator  Chapter 3 Hardware installation  Chapter 4 References
  Hardware installation Manual   OpenVox Communication Co. Limited.   URL: www.openvox.cn   Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049  6Tables  Table 1: List of used Abbreviations  Table 2: P1,P1 Assignments Table 3: P3 Assignments Table 4: P4 Assignments Table 5: Map List between core module and PMC Connectors  Figures Figure 1 V100_PTMC Diagram Figure 2 V100_PTMC  Figure 3 PMC Connectors in V100_PTMC Figure 4 Dip Switch Figure 5 Front panel Figure 6 View V100_PTMC Installation
  Hardware installation Manual   OpenVox Communication Co. Limited.   URL: www.openvox.cn   Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049  7Conventions If not otherwise specified, addresses maps are written in hexadecimal notation, identified by 0x.  Table 1 gives a list of the abbreviations used in this document:   Table 1: List of used Abbreviations    About This manunnal   This manunnal is technical reference for the V100_PTMC for CompactPCI. Here is a brief description of the information that you will find in this manual.     Chapter 1 provides an overview of the V100_PTMC as well as a brief information regarding  feature,Codec  support  ,target  applications  and  system  notification specifics.     Chapter 2 contains an  indepth product diagram and necessary information for  integrating the V100_PTMC into your CompactPCI system. Chapter 3 contains the detailed information on unpacking and installing the
  Hardware installation Manual   OpenVox Communication Co. Limited.   URL: www.openvox.cn   Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049  8V100_PTMC into your PCCs . Chapter 4  lists standards and references  Chapter 1 Overview  Overview Because  of  its  low  bandwidth  requirements,  The  voice  data  compression Codecs  ,such  as  G.729,G.726,AMR,G.722,iLBC  ,etc.  are  commonly  used  in  VoIP applications.The G.711 Codecs is commonly used in legacy telephone network. For bridging TDM to VoIP connectivity ,it needs Codec transformation. Compared with transformation in software,The V100 ,Based Multicore-DSP ,can convert more sessions of transcoding,relieve the host CPU resources. The V100 card, are rated to handle up to 32,64,128,256,400 bi-directional Codec transformations, without additional licensing fees 1 for transcoding.  The V100_PTMC is a PMC for transcoding.In additon, It is a PTMC for extending PMC to support stand telecom and telephony interfaces. It is usable with a wide range of PCC ,PT2CC,PT3CC,PT5CC.and can provide CompactPCI/fornt-panel Gbe/Backplane Gbe/Local CT  media/control flow paths. These features can save the cost and support flexible applications. The V100 can be worked with Asterisk® and FreeSWITCH® .In addition, the Media message-based API makes the development easy since the messages and media flow communicate between the PCC’s host and V100_PTMC through Ethernet interface .      Feature  • High density  up to 30 to 400 Transcoding  • No addionnal License Fee1 • Compliant with PICMG 2.15(PTMC) electrical specification and IEEE 1386,IEEE1386.1(PMC)mechanical specifications • Configurable for PT2MC/PT3MC/ PT5MC • Local CT Bus allowing flexible routing of TDM timeslots both between the PTMC   Sites and the H.110 backplane CT Bus. • PT5MC includes Gbe connectivity to backplane resources • PMC/PT2MC/PT3MC include Gbe connectivity to front panel • Multi Media/Control Flow Paths • Relieve Host CPU Load • Release API for Integration • OS : Linux and Windows  • Integrates in Asterisk® and FreeSWITCH® • Support distributed or intergrated Application
  Hardware installation Manual   OpenVox Communication Co. Limited.   URL: www.openvox.cn   Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049  9Codec Support  • G.711         • GSM-FR • G.722         • GSM-EFR • G.722.1       • AMR • G.726         • AMR-WB (G.722.2) • G.729AB       • iLBC   1 Except  for AMR and AMR-WB Target Applications •Hosted VoIP GateWay •Conferencing Server •IVR Server •Distributed Office PBX •Call Centers  Dimensions • Compliant with IEEE1386 mechanical specifications • 149.0x74.0mm (PCB)  Interface •PCI :32bit 33/66MHz •Local CT •10/100/1000 BASE-T RJ45   •UART •Backplane Gbe •PMC Connector Power Requirments • 2.2A @3.3V  Operating Temperature Range •0 – 50 °C Humidity •10 TO 90% NON-CONDENSING Hardware and Software Requirement
  Hardware installation Manual   OpenVox Communication Co. Limited.   URL: www.openvox.cn   Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049  10•PCC,PT2CC,PT3CC,PT5CC •Windows/Linux in Host  Chapter 2 Hardware Architecture Figure 1 presents the functional blocks of the V100_PTMC.  Figure 1 V100_PTMC Diagram  The flollowing is the V100_PTMC image                  Figure 2 V100_PTMC
  Hardware installation Manual   OpenVox Communication Co. Limited.   URL: www.openvox.cn   Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049  11Introduction   The V100_PTMC is a high density codec transcoding card. In addition,it is extended to provide voice quality processing features such as voice echo cancellation and adaptive noise reduction.The V100_PTMC is a PTMC,which is compliant with PCIMG2.15/ IEEE1386,IEEE1386.1, and can be integrated into customer’s CompactPCI system.The V100_PTMC also features ethernet ports and local_CT Bus on board. And can handle IP TO IP transcoding or IP TO TDM transcoding.   The V100_PTMC is composed a core module and a PTMC extender board. The core module contains Vocallo DSP ,Ram,Flash,PowerSupply ,UART,2 Giga Macs and TDM bus interfaces. The extender PTMC board contains PMC connectors,Giga NIC, Glue ,Dip Switch,front panel RJ45 interface.it connects core module and PCC/PTxCC.  Vocallo DSP and core module    The Vocallo DSP,which is used to address transcoding, is located in the core module,The media flow enters and exits through  inherent  Mac interfaces/TDM Bus interface.The control flow enters and exits through inherent  Mac interfaces.  Giga NIC   The Giga NIC located in extender PMC board bridges  the host located in PCC/PTxCC through PCI Bus to the vocallo DSP through Eth1.  Front panel RJ45   The front panel RJ45 in extender  PMC  board  supports to  provide the packet interface to access the DSP. In some applications,the remote host can communicate  the Vocallo DSP through the front panel RJ45 interface.The interface is enable except PT5MC option is chosen.  P4 in PTMC connectors    The P4 is another packet interface to access the DSP.This interface is enable when PT5MC option is chosen.  PTMC connectors   There are four PTMC connectors,which are Compliant with PCIMG2.15(PTMC) electrical specification and IEEE1386,IEEE1386.1(PMC)mechanical specifications, located in V100_PTMC.
  Hardware installation Manual   OpenVox Communication Co. Limited.   URL: www.openvox.cn   Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049  12          Figure 3 PMC Connectors in V100_PTMC The following tables are the connectors Pin Assignments.  Table 2: P1,P1 Assignments
  Hardware installation Manual   OpenVox Communication Co. Limited.   URL: www.openvox.cn   Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049  13Table 3: P3 Assignments
  Hardware installation Manual   OpenVox Communication Co. Limited.   URL: www.openvox.cn   Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049  14                Table 4: P4 Assignments    Glue    The glue located in extender PMC board bridges the UART and H.110 bus in PMC carrier/PTxCC to the Uart and TDM bus in core module.
  Hardware installation Manual   OpenVox Communication Co. Limited.   URL: www.openvox.cn   Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049  15Table 5: Map List between core module and PMC Connectors  * For more flexible TDM customization ,the source code and object code of glue can be acquired from OpenVox.The customers can rebuild the glue to suit their PTCC.   Dip Switch The Dip switch located in extender PMC board is for configuring the V100_PTMC options. The following is the Dip Switch Outline.
  Hardware installation Manual   OpenVox Communication Co. Limited.   URL: www.openvox.cn   Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049  16  Figure 4 Dip Switch Pin 1 is Vocallo DSP Device ID option. If it is switched ON, the DSP ID is 0x FE,If it is switched Off(default) ,the DSP ID is 0x FF. If dual V100_PTMCs are provided on the same PCC/PTCC, one of them should be set to 0x FE ,and the other should be set to 0x FF.      Pin 2 is TDM clock of Vocallo DSP enable option.If it is switched ON,The TDM clock is disable(default).If it is switched Off,the TDM clock is enable.   Pin3-Pin5  are  PTMC  configuration  option.The  V100_PTMC  supports  3  PTMC configuration(PT2MC,PT3MC,PT5MC) via Pin3,Pin4,Pin5. On means 1,Off means 0. If Pin3-Pin5 is set to 010, PT2MC (default)configuration is enable. If Pin3-Pin5 is set to 011, PT3MC configuration is enable. If Pin3-Pin5 is set to 101, PT5MC configuration is enable.   Figure 5 Front panel LED indicator     There are 4 LEDs located in front panel.(See Figure 5) The T/R blinking indicates the front panel RJ45 packet interface or P4 in PTMC connectors packet interface is transmitting or receiving. The LNK light indicates he front panel RJ45 packet interface or P4 in PTMC connectors packet interface is linking up. The CFG2/3 is PT2MC/PT3MC indicator. Red light means V100_PTMC is PT2MC option and the PTCC is PT2CC compliant.Green light means V100_PTMC is PT3MC option and the PTCC is PT3CC compliant. The CFG5 is PT5MC indicator. Green light means V100_PTMC is PT5MC option and the PTCC is PT5CC compliant.
  Hardware installation Manual   OpenVox Communication Co. Limited.   URL: www.openvox.cn   Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049  17             Chapter 3 Hardware installation 1. Make sure the V100_PTMC is compatible with your PCC/PTCC. V100_PTMC can be worked   with  PCC32,PCC64,PT2CC,PT3CC  and  PT5CC  theoretically.  In  practice,Electrical compatibility of combinations that include user-defined I/O,whether PMC or PTMC compliant,must be  checked carefully. The V100_PTMC  I/O pins is 5V tolerant for 3.3V.  It  is  recommended  that you  ask  OpenVox  whether  the  V100_PTMC suit  your application.  * V100_PTCCEVB that is a PCI card for evaluating V100_PTMC  is available. 2. Unpacking Inspect the packing container for any damage. If this container appears damaged, immediately contact the company responsible for the shipping and report the damage before opening and unpacking the container. It is recommended that you also notify OpenVox. 3. Make sure the PCC/PTxCC that have V100_PTMC installed complies with the country specific safety regulations. 4. Power off your PCC/PTxCC and unplug it from its AC power source. 5. Attach a Anti-static Wrist Strap to your wrist. 6. Configuring the Dip Switch to the right position. 7. Open the cover of the ComppactPCI Platform. 8. Remove the filler plate from the front panel of the PCC/PTxCC .(See Figure 6) 9. The V100_PTMC must be positioned with care to avoid damaging components against the voltage keying post. 10. The V100_PTMC bezel enters the front panel of the PCC/PTxCC into alignment with the signal connectors. (See Figure 6) 11. Mounting the screws. (See Figure 6) 12. Replace the cover of the PCC/PTxCC. 13. Plug the UTP cable into RJ45 Jack of the V100 only if the Media/Control Path is  the front panel RJ45/UTP.  14. Plug the AC power source.and follow the software installation manual.  Figure 6 View V100_PTMC Installation
  Hardware installation Manual   OpenVox Communication Co. Limited.   URL: www.openvox.cn   Tel: +86-755-83535362,82535462,82535095 Fax: +86-755-8346049  18 Chapter 4 References • ECTF H.110 Hardware Compatibility Specification: CT Bus revision 1.0 • IEEE P1386 2.4a March 21, 2001 Common Mezzanine Card Family • IEEE P1386.1 Draft 2.4 Jan. 12, 2001 PCI Mezzanine Cards, PMC • PCI Local Bus Specification Revision 2.2 • PICMG 2.15 1.0 PCI Telecom Mezzanine/Carrier Card Specification • PICMG 2.15 R1.0:ECN 2.15-1.0-001 10/100/1000 Ethernet MDI Links on PTMC • PICMG 2.16 R1.0 CompactPCI Packet Switch Backplane • PICMG 2.5 R1.0 Computer Telephony • PICMG 2.9 R1.0 CompactPCI System Management Specification • VITA 32 -199x Processor PMC Standard Draft 0.41 Sept. 8, 2000 • VITA 39 -2003(R2009) PCI-X Auxiliary Standard for PMCs and Processor PMCs  FCC NOTE:This device complies with Part 15 of the FCC Rules.  Operation is subject to the following two conditions:  1. This device may not cause harmful interference, and 2. This device must accept any interference received,  including interference that may cause undesired operation.   FCC CAUTION  changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

Navigation menu