Opticon user's manualpage1 INTRODUCTION 32 INSTALLATION 42.1 UNPACKING 42.2 DETAILED VIEW 52.2.1 Dimensions of terminal 52.2.2 Details of terminal 52.2.3 Display of terminal 62.2.4 Dimensions of cradle 72.2.5 Details of cradle 72.3 HANDLING PRECAUTIONS 82.4 ASSEMBLY 92.4.1 Terminal 92.4.2 Cradle 92.4.3 Terminal on cradle 102.5 INSTALLING, REPLACING AND CHARGINGBATTERIES 102.5.1 Required batteries 112.5.2 How to charge the rechargeablebattery pack in the cradle? 112.5.3 When to replace or recharge themain battery? 112.5.4 When to replace the backup battery? 112.5.5 How to (re)place the main batteryin the terminal? 122.5.6 How to (re)place the backup batteryin the terminal? 132.6 INSTALLING IN A SYSTEM 142.6.1 Terminal to computer 142.6.2 Single cradle to computer 142.6.3 Cradle network 142.6.4 Dip switch settings on cradle 153 OPERATION OF THE TERMINAL 154 SCANNING 164.1  How to read the barcode 164.2  Barcode reading problems 16USER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLE3page5 PIN OUT  175.1 RS232 cable for terminal 175.2 RS485 cable for cradle network 175.3 RS232 cable for cradle 176 SPECIFICATIONS 186.1 SPECIFICATIONS TERMINAL 186.1.1 Electrical specifications 186.1.2 Optical specifications 186.1.3 Physical specifications 186.1.4 Functionality 186.1.5 Environmental specifications 196.1.6  Supported Barcode symbologies 196.2 SPECIFICATION CRADLE 196.2.1 Electrical specifications 196.2.2 Functionality 196.2.3 Environmental specifications 196.2.4 Physical specifications 197 TROUBLESHOOTING 207.1 COMMUNICATION PROBLEMS 217.2 READ OPERATION PROBLEMS 217.3 TERMINAL PROBLEMS 218 PRODUCT ORDERINGINFORMATION 23USER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLEPHL2700-barcode-ver1-00 / printed 11 00CONTENTSCAUTION: This user’s manual may be revised or withdrawn at any time without prior notice.Copyright 2000, Opticon Sensors Europe B.V.All rights reserved.This manual may not, in whole or in part, be copied,photocopied, reproduced, translated or converted toany electronic or machine readable form withoutprior written consent of Opticon Sensors Europe.Limited warranty and disclaimersBy opening the package of this product you agree tobecome bound by the liability and warranty condi-tions as described below.Under all circumstances this manual should be readattentively, before installing and or using the product.In no event, Opticon Sensors Europe will be liable forany direct, indirect, consequential or incidental dam-ages arising out of use or inability to use both thehardware and software, even if Opticon has beeninformed about the possibility of such damages.A serial number appears on all Opticon products.This official registration number is strictly related tothe device purchased. Make sure that the serial num-ber appearing on your Opticon device has not beenremoved. Servicing by our Repair Department canonly be carried out under warranty.All Opticon products are warranted for a period ofone year after purchase, covering defects in materialand workmanship. Opticon will repair or, at its opin-ion, replace products that prove to be defective inmaterial or workmanship under proper use duringthe warranty period.Opticon will not be liable in case modifications aremade by the customer. In such case the standardrepair charge will be applicable. The standard chargefor repair will also be applicable in case no defect isfound at all. These rules also apply for products thatare still under warranty. Therefore, you are advised tohave the product specifications always at hand.Trademarks used are property of their respectiveownersThis terminal is a compact, programmablehandheld terminal, and is well suited for avariety of indoor portable applications. It has abuilt-in laser scanner that can scan all popularbar code labels at varying distances.User’s applications can be downloaded to theterminal to adapt the terminal to the user’s situation.Operating power is supplied by the main battery. The main battery may consist of arechargeable Ni-MH battery pack (to becharged in cradle), or dry cell batteries, eithernon-rechargeable or rechargeable (to becharged in external charger).The cradle is a communication station for datatransmission between the (host) computersystem and the terminal. It communicates withthe terminal through their IrDA interface. Thecradle will also charge the rechargeable battery pack in the terminal through the electrical contacts.The IrDA interface on the terminal enablesyou to communicate with other devices thatuse IrDA communication, like portable computers, notebooks and organisers.Additional a RS232 cable can be used.The RS232 cable can be used for direct communication between the (host) computersystem and the terminal, for example to download software to the terminal.INTRODUCTION31The general use and functioning of theterminal together with the cradle will bedescribed in this manual.The exact behavior of the terminaldepends on the user application that isrunning. For instructions about applicationsplease consult the documentation ofthat software.Please read this manual carefullybefore using the terminal, to maximisethe efficiency of this terminal.
Opticon user's manualCRADLEIRU 2700:CradleADDITIONALSIRU2700:Power Supplyfor cradleCable for cradleRS232 cable DB9 FCable for cradleRS485 network cableWhen you remove the packing, please checkfor any physical damage. We recommend thatyou save all packing material, as it should beused whenever you need to ship your terminal(eg. for service). Damage due to improperrepacking is not covered by the warranty.Apart from the terminal or cradle, additionalitems might be ordered and supplied.If there are any missing parts please contactyour supplier.Do not remove the label !On the back of every unit you will find a label.The label is attached by the manufacturer andincludes information about the function it supports and a serial number. Do not removeit.USER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLE52.2.1Dimensions of terminal2.2.2Details of terminal:USER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLETERMINAL PHL2700:Package contents:TerminalBackup batteryHandstrap41. Reading windowlaser beam for barcode reading will be emitted from here2. LCD Displayfor displaying information3. LED indicatorcan be used to indicate results, for examplebar code reading / status of communication4. Power keyfor switching power On/Off5. Trigger key  definable by user’s applicationtypical use: read key, switches laser beam on for barcode reading6. Quick keys  definable by user’s applicationtypical use: menu scroll keys or yes/no input 7. Control keys  definable by user’s applicationfor controlling basic functionstypical use as below:CLR : Cancel inputBS : Back spaceS : Shift key“S”on the LCD display indicates the terminal is in the shift mode8. Character keys  definable by user’s applicationtypical use: for input of alpha-numeric and punctuation  characters9. ENT key  definable by user’s applicationtypical use: for confirming input10. Function keys  definable by user’s applicationuser programmable keys, to be used together with shift key.typical use as shown on next page11. Battery case coverfor housing main battery12. Optical interface windowfor infra red communication13. Hand strap pillarfor attaching hand strap14. Electrical contactsfor power supply from the cradle IRU2700to terminal 15. RS-232C connectorfor connecting external device, or for systemexpansion, through Opticon RS232 cableINSTALLATION322.1   UNPACKING 2.2   DETAILED VIEW12356478910121113141553mm177mm31mm66mm 41mmADDITIONALSPHL2700:Battery Pack for terminalContents:Battery caseDry cell batteriesBattery Pack for terminalrechargeable batterypackCable for terminal RS232 cable
Opticon user's manualUSER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLE72.2.3Display of terminalThe liquid crystal display of the terminal is typically used to show program prompts,instructions and data, as defined in the user’sapplication.The display has the following default options:Special purpose symbols in display:The symbols will be shown in the bottom partof the display and indicate status.Description of the display indicatorsMain Battery indicatorOff: Sufficient battery powerOn: Battery low.Replace battery immediately.Backup Battery indicatorOff: Sufficient battery powerOn: Battery low.Replace battery immediately.Alpha mode on(Shift-key activated)BacklightThe display is provided with a backlight.When the backlight is turned on, the powerconsumption increases. To extend the life timeof your batteries use the backlight as little aspossible.2.2.4Dimensions of cradle2.2.5Details of cradleUSER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLE6Description of the function keysIn the shift mode, back light on/off, contrastadjustment, and cursor movement can bedone by these keys.(The user’s application can give different definitions to the keys)shift modefunctions:F1 (-) input minus signF2 (DEL) delete one characterF3 (SP) input spaceF4 (BL) toggle with back lightF5 (<--), F6 (-->) move cursorF7 ( ), F8 ( ) adjust contrast1. DC input socketinput for AC adaptor2. RS 485 socketfor connecting another cradle in multi-drop RS485 network, through Opticon RS485 cable3. RS 232 C socketfor connecting to PC or modem, through Opticon RS232 cable4. Switch for terminal detectionto detect if a terminal is placed on the cradle5. Electrical contactsfor power supply to terminal PHL2700If rechargeable Ni-MH battery pack is inserted in the terminal the pack will be charged through the electrical contacts6. DIP switchessetting parameters of the infrared interfaceswitches are located behind the cover7. Optical windowwindow for optical data transmission8. LED indicatorindicating powerLED on: power is onLED off: power is off150mm90mm81mm
Opticon user's manualUSER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLE9Use of the terminalOperate the terminal keys bypressing them lightly with yourfingertips or with something softand round.Pressing the keys with a sharppointed object (for eg. a ball-point) can damage the keys.Avoid temperature changes.Sudden temperature changescan cause condensation toform on the terminal. Using theterminal while condensation ispresent can cause malfunction.Always wait until the condensationclears naturally before attemptingoperation.Do not leave the terminal in anarea where static charge isaccumulated, or near deviceswhere electromagnetic emissionis generated.Do not place any objects on topof the terminal. Do not lay theterminal face down.Doing so can cause accidentaloperation of the [PW] key or[ENTER] key, which can dis-charge your batteries orchange settings you do notwant to be changed.Cleaning of the terminalClean the optical interface window periodically.MaintenanceThere are no user-serviceableparts inside the terminal or thecradle. So do not try to take itapart. The manufacturer will notbe liable for any damagecaused by the customer.In case of malfunction that can not be solvedby the trouble-shooting instruction in theappendix, please consult our service department.Follow the next steps to make your terminalready for installation in a system, that isdescribed further in the manual.2.4.1.TerminalTo avoid drop use the hand strap.Fix the small cord of the strap around the pillar of the terminal (ref. 1)Insert the handle of the strap in the thin loop (ref. 2)The strap is fixed to the terminal (ref. 3)Hold the handstrap around the wrist when carrying the terminal (ref. 4) Do not swing the terminal around.Start with a full batteryTo be sure of proper operation, it is advised to start with a full battery, charge the battery pack according to the instructions in the next chapter.Click the battery pack into the terminal,as instructed in the next chapter.!USER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLE8To avoid malfunctioning and to ensure yearsof trouble free operation, pay attention to thefollowing:General useDo not use or leave the productin extremely hot areas - likedirect sunlight, near a heater, or in a car - or in areas that arevery cold, humid, moistured ordusty.Do not expose the product torain or water splashDo not subject the the productto very strong impact, do notthrow or drop the terminal fromlarge heights.Do not allow a mechanicalshock to the product.General cleaning instructionsClean the exterior by wiping itwith a soft, dry cloth. Do notuse much water.Do not use thinner, white spiritor other solvents. These candiscolour the case and the keysand has a negative effect onthe lifetime of the keys.Use of the cradleDo not place any other product than the PHL-type terminal in the cradle.Cleaning of the cradleAvoid touching the contacts in the cradle. Thecontacts must stay as clean as possible tomaintain optimal charging capacity.Do not use water when cleaning the cradle.This can cause malfunction in the chargers.2.3   HANDLING PRECAUTIONS!!2.4   ASSEMBLY2.4.2CradlePlace for mountingPlace the cradle in normal office conditions.Avoid a place under strong light.Otherwise IrDA communication may be disturbed.Power ConnectionAttach the DC jack of the AC adapter into the socket of the cradle.Then connect the AC adapter to the mains outletWhen the terminal PHL2700 with the rechargeable battery pack is placed in the cradle, the LED on the cradle turns green.When the terminal PHL2700 with penlite batteries is placed in the cradle, no indication is given by the cradle.2.4.3.Terminal on cradleTake notice that the IRU2700 cradle is designedfor the PHL2700 terminal. No other types ofterminals can be placed into this cradle.Place the terminal in the cradle as shown inthe illustration:1 23 4
Opticon user's manualWrong use of batteries might causeserious damageto the terminal or to the cradle.In order to avoid damage it is very important to take notice of the instructions.USER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLE112.5.1Required batteriesThe terminal needs both main battery andbackup battery for operation.Main BatteryThe main battery can consist of:Rechargeable Opticon battery pack (NiMH),to be recharged when placing the terminal PHL2700 in the cradle IRU2700.Dry cel Opticon batteries (Alkaline).To be used together with Opticon battery case for dry cell batteries.These batteries are not rechargeable.Other batteries. All batteries have to be used together with Opticon battery case for dry cell batteries.Batteries that are not supplied by Opticon must be AA-size and absolutely leakproof.If rechargeable batteries are used, they need to be recharged by a separate battery charging device.Opticon recommends to use Opticon batteries(Opticon rechargeable battery pack or Opticondry cell batteries) only.Backup BatteryUse only one type of battery for backup:Backup battery:CR2032 Li (Lithium, button type).2.5.2How to charge the rechargeable battery pack in the cradle?Make sure that the Opticon rechargeablebattery pack (Ni-MH) is inserted in the terminal.If the terminal with the right rechargeable battery pack is placed in the cradle, the LED on the cradle will turn green.The rechargeable battery pack inside the terminal will be charged automatically for a period of 8 hours when the terminal is placed in the cradle.When the battery case with penlite batteries is inserted in the terminal, it will not be charged by the cradle.If the terminal with penlite batteries is placed in the cradle, the cradle will not show an indication.2.5.3When to replace or recharge the main battery?There are 2 reasons for replacing the mainbattery;as soon as possible after the battery indicator  appears on the display.when you are not using the terminal for an extended period.For instructions of (re)placing the main batterysee paragraph 2.5.5.2.5.4  When to replace the backup battery?When low battery mark  appears, replace the battery without delay.For instructions of (re)placing the backup battery see paragraph 2.5.6.!!Only use recommended batteries.When other batteries are used, defects or other problems can occur. Before installing(new) batteries, please make sure you areusing the recommended batteries.Do not make a mistake regarding the polarity (+ , -) of the battery.The terminal will not work when the polarity is incorrect.Use the right charger for batteriesOnly the rechargeable Ni-MH battery pack of Opticon can be charged inside the terminal in the cradle IRU2700. Other rechargeable batteries need to be recharged in a separate battery charging device.Follow the instructions for installing,changing and removing the batteries very strictly.The products are not warranted for damage, defects, malfunction or loss of data, resulting from incorrect use of batteries.!!!!USER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLE10Insert full batteries before use of the terminal.Never remove the main battery pack while the terminal is turned on.Doing so can cause data in the terminal to be deleted.When you do not use the terminal for a long time, make sure the main battery has enough capacity.When there is not enough capacity the backup battery will be used up.!!!2.5   INSTALLING, REPLACING AND CHARGING BATTERIES
Opticon user's manualUSER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLE122.5.5How to (re)place the main batteryin the terminal?Only use batteries as specified in paragraph 2.5.1.If you have data stored, make sure thebackup battery is placed and full enough, to avoid data loss.Before installing a battery case with penlitebatteries:Make sure you use the right battery size.Place 2 batteries in the battery holder aligning plus (+) and minus (-) ends as shown on the battery holder.The instructions for installing the rechargeablebattery pack are also applicable for the batterycase with penlite batteries.Unlock cover: Open the switch (shift to the right) and remove the battery case cover (ref. 1)Remove main battery: Hold the battery case while pressing on both sides and lift it (ref. 2)Place main battery: Take the battery case.Check if the charging contacts of the case align with the contacts inside the battery compartment (ref. 3)Fit main battery: First press the pack into the direction of the terminal nose.Than press the pack tight into the housinguntill it cliks (ref. 4)Fit cover: Place the battery case cover andlock the switch (shift to the left)(ref. 1)!!USER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLE132.5.6How to (re) place the backup battery in the terminal?Make sure that the main battery is full enough while changing the backup battery.Only use CR2032 Li (Lithium, button type) battery.Unlock cover: Open the switch (shift to the right) and remove the battery case cover (ref. 1)Open lid: Place your thumbnail below the saving of the lid to open it (ref. 5)Remove backup battery: Take the old battery out of the compartment.Place backup battery: Make sure that the positive side of the backup battery is pointed upwards and place it in the compartment (ref. 6)Close lid: Press the lid downwards until it clicks into the compartmentFit cover: Place the battery case cover andlock the switch (shift to the left)(ref. 1)!!23413----> openclose <---- 256
Opticon user's manualUSER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLE15USER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLE142.6.4DIP switch settings on cradleSetting the DIP switches on or off will result indifferrent baudrates and enabled or disabledfunctions of the cradle.Open the cover of the DIP switches on the bottom of the cradle in order to reach the DIP switches.Turn the DIP switch ON by moving it upwards into the direction of the dipswitch number.Turn the DIP switch OFF by moving it downwards into the direction OFF.The functionality of the terminal is determinedby software, the so-called user application,that is running on the terminal.Usually, the terminal is not equipped with software and has no functionality. At first theuser application must be loaded before the terminal can be used for barcode scanning.Tools for developing a user application on thePC for use on the terminal, as supplied byOpticon are:Application Generator PotStar (Limited or Professional)C language: Microtec ANSI-C compiler and C library for handheld terminals.The user application must be downloadedfrom the PC into the terminal. You can use thecradle, an RS232 cable or an infrared adapterfor communication between the terminal andthe PC. A program on the PC will send theuser application to the terminal, where it isstored in FlashROM memory.When the functionality of the terminal is definedby the application it is ready for operation.In a typical application you will press the triggerkey and scan a bar code label as described inthe next chapter. Scanned data and dataentered from the keyboard is stored in theterminal's RAM. The user application can usethis data in subsequent steps.The collected data can be transmitted to the PCfor further processing. For data transmissionyou can use the cradle, an RS232 cable or aninfrared adapter to connect the terminal to thePC.Exercise caution at all times when working with AC-powered equipment.Turn off your devices before installation.Because of the special pin-out of the connectors, use the cables supplied by the manufacturer.When you need another cable for a certain device, that is not supplied,contact your  supplier to purchase the right cable. In case another cable is used, take notice of the pin-out specifications further in this manual.Connection sequencefor single cradle:Place the cradle in normal office conditions, avoid a place under strong light.Disconnect the power supply.Set the required DIPswitches for baud rate and function.Connect the interface cables.Connect the power supply.Place the PHL2700 terminal in the cradle.!!!!2.6.1Terminal to computer2.6.2Single cradle to computer2.6.3Cradle networkConnection sequencefor cradle in network:Set all cradles to the same baud rate (by DIPswitch)Only 1 cradle in the network will be connected to the PC through one RS232 cable. On this cradle the DIPswitch for RS232 connection must be enabled. Through this connection all cradles can communicate to the PC.A maximum of 16 cradles can be connected in a network through RS485 cables. For the cradles that are not directly connected to the PC  the DIPswitch for RS232 connection must be set to off.The first and the last cradle in the network must have the termination resistors set by dipswitch.3 POLECONNECTOR RS 232DB9HOSTPHL 2700DB9CRADLE RS 232DB25 / DB9HOST FUNCTIONSRS 232CONNECTIONRS485TERMINATORRS485TERMINATORBAUDRATE *BAUDRATE *BAUDRATE *ONin usein usein use------OFFnotin usenotin usenotin use------DIPSWITCHSW 1SW 2SW 3SW 4SW 5SW 6SW4OFFONOFFONOFFONOFFONSW5OFFOFFONONOFFOFFONONSW6OFFOFFOFFOFFONONONON* )BAUDRATE    1200    2400    4800    9600  19200   (default)  38400115200  NONEDEFAULTONOFFOFFOFFOFFONOPERATION OF THE TERMINAL332.6   INSTALLING IN A SYSTEMRS 485sw 1 = offsw 2 = offsw 3 = offRS 232TRANSMISSIONHOST  TERMINATED   RS 485sw 1 = onsw 2 = onsw 3 = onRS 485   TERMINATED sw 1 = offsw 2 = onsw 3 = on//
Opticon user's manualUSER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLE17USER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLE16The terminal is a Class I laser product conforming to the strictest laser safety standards. However, we recommend that you avoid looking directly into the laser beam emitter, or pointing the laser beam directly into someone’s eyes.Fit the bar code in the laser beam frommargin to margin and pass the scanner downward over the bar code, as shown in thescan position illustration.When reading a small bar code, decrease thedistance between the terminal and the bar code.For larger bar codes, position the terminal sothat the bar code fits into the laser beam.When reading a very high density bar code,decrease the distance between the terminaland the bar code. For a low density bar code,increase the distance between the terminaland bar code.4.2   Barcode reading problemsWhen the barcode can not be read, try the following:Change the angle between the bar code and the terminal.Change the distance between the bar code and the terminal.If the bar code is larger than the laser beam, try moving the terminal a bit further away from the bar code.!5.1   RS232 cable for terminal PHL17005.2RS485 cable for cradle network IRU27005.3RS232 cable for cradle IRU2700Please take care of the handling precautions.Please make sure that the terminal is installed according to the installation instructions.Never remove the main battery pack while the terminal is turned on.Doing so can cause data in the terminal to be deleted or corrupted.4.1  How to read the barcodeThe scanning sequence is defined by theuser’s application. A typical sequence is:Press the [PW] key to turn power on.Check the display for the message:READ BAR CODEPoint the terminal to the barcode and press the Trigger key.Point the laserbeam to barcode as shown in the scan position illustration.The barcode will be read and the reading results will be indicated.A ‘Good Read’means that the scanner haseffectively recognised and decoded the barcode. In most cases, the application programwill provide an indicator signal or a buzzer signal to indicate a good read to the user.When the read is incorrect you can try again,paying attention to the instructions in thischapter.!!!SCANNING34good readscan positionincorrect readscan positionsPIN-OUT35Jackplug3 pole(terminal)123DB 9connectorFemale(PC)235SignalRxDTxDGNDRS232cable SignalTxDRxDGND1913Modularplug(6P6)123456Modularplug(6P6)-2345-16NetworkcableRS485Signal-RD+RD-SD+SD--16DB 9 male(cradle)   3   2   6 + 1   5   4   8   7DB 9female(PC)   2   3   4   5   6 + 1   7   8SignalRxDTxDDTRGNDDSRRTSCTSRS232cableSignalTxDRxDDSRGNDDTRCTSRTS1919In/Out(cradle)INOUTOUT--OUT-Note--ON (fixed)-not usedON (fixed)not used5.35.25.1
Opticon user's manualUSER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLE19Transmission speed RS232 direct cable:2400 - 115200 baudRS232 cradle:2400 - 115200 baudIrDA terminal:2400 - 115200 baud6.1.5   Environmental specificationsTemperature 0 - 50 oC in operation-10 - 60 oC in storageHumidity  20 - 80 %  in operation(non condensing)  20 - 90 %  in storageShock: drop: 1.5 m drop onto concrete surfaceShock: vibration: 10 - 50 Hz with 1G for 30 min, cycle for X,Y,Z.Ambient light  fluorescent   3.000 lux max.rejection direct sun   50.000 lux max.Emission According to EN50081, part 1Immunity According to EN50082, part 1Protection againstdust and moisture According to IEC529, IP 42Safety, Laser class According to IEC825, Class I laserproduct6.1.6   Supported symbologiesChinese Post 2of5Codabar incl. ABC and CXCode 39Code 93Code 128EAN-8 incl. +2,+5EAN-13 incl. +2,+5IATAIndustrial 2of5Interleaved 2of5Italian PharmaceuticalLaetusMatrix 2of5MSI/ PlesseyUK/ PlesseyS-CodeTelepenUPC-A incl. +2,+5UPC-E incl. +2,+56.2.1   Electrical specificationsBattery charging time when battery in terminal:8 hours charge6.2.2   FunctionalityInterfaces supported RS232RS485Serial communication RS232 Baudrate:1200 - 115200RS485 Baudrate:1200 - 115200Transmission modes Half duplex RS232Half duplex RS485Parity Odd, Even, None6.2.3   Environmental specificationsTemperature 0 - 40 oC in operation-20 - 60 oC in storageHumidity   30 - 85 % in operation(non condensing) 30 - 90 % in storageShock: vibration: 10 - 50 Hz with 1G for 30 min,cycle for X,Y,Z.Emission According to EN50081, part 1Immunity According to EN50082, part 16.2.4   Physical specificationsDimensions (l x w x d) 150 x 90 x 81 mm Case material ABSWeight 250 gStandard connector RS232 - D Sub 9P FemaleRS485 - 6 pins modular plugUSER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLE186.1.1   Electrical specificationsMain battery rechargeable pack: Ni-MHdry cell: Alkaline penliteoptional: other 2 x AA-size penliteMain battery Ni-MH: When making every 5 operating time seconds 1 scan with 1 sec laserbeam on and 0.2 sec.green LED on and 0.2 sec.buzzer on,   operating time is:approx. 40 hoursAlkaline: When making every 5 seconds 1 scan with 1 sec laserbeam on and 0.2 sec.green LED on and 0.2 sec.buzzer on,   operating time is:approx. 78 hoursDifferent operation conditions affect the operating timeUse of other penlite batteries affect the operating timeBackup battery Lithium (CR2032)Backup battery  If fully charged: 30 days backup operating time timeBattery Low voltage indicated on themanagement terminal display.When battery is low the terminal switches off automatically.Charging method Rechargeable Ni-MH pack in terminal via cradle6.1.2   Optical specificationsLight source 650 nm visible laser diodeScan rate 100 scans/secDecode rate 100 decodes/secReading width 62 mm at 30 mm111 mm at 100 mmResolution at PCS 0,9 0.15 mm (6mil)Depth of field 0 - 140 mm (at PCS 0.9, res. 0.25)6.1.3   Physical specificationsDimensions (l x w x d) 177 x 62 x 41 mmCase material ABSWeight body (excl. battery): 175 gDirect cable (optional) RS232 - DB9 female6.1.4   FunctionalityMemory ROM: 32 kBFlashROM (for O/S and program): 512 kBfast RAM: 2kBbattery backed up D-RAM (for data): 8 MBMicroprocessor 16-bitReal time clock Quartz RTC, time and date programmable, leap year handling, (accuracy + 60 sec./month)Display 128x64 Pixels graphic LCDwith backlight Character fonts:4/8 lines x 16 characters5/10 lines x 21 charactersKeyboard 27 keys total (26 keys user definable)8 Function keysAlpha/Numeric modeTrigger mode ManualProgramming Functionality is provided by user application. The applicationmay be downloaded from PC via cable, com port or IrDA.Interfaces supported RS232 by direct cableRS232 by cradleIrDA on terminalSPECIFICATIONS366.1   SPECIFICATIONS TERMINAL6.2   SPECIFICATIONS CRADLE
Opticon user's manualUSER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLE21No communication from the cradle to thedevice, or data is transmitted distorted orcorrupted.Power indicator of the cradle is not green.Check if the battery case cover of the PHL2700 is closed properly.Clean the optical interface window of the cradle and/or terminal, and try again.Check all cables.When the power indicator is still not green, the cradle needs service.No data transmittedThe cradle will only work if connected to a PC.Clean the optical interface window of the cradle and/or terminal, and try again.Data is corrupted, or no data is transmitted.Is the proper baudrate selected?The computer needs the same baudrate as the terminal.Clean the optical interface window of the cradle and/or terminal, and try again.The terminal looses data when the batterypack is removed for a short period.The backup battery is empty.Replace the Lithium CR2032 battery bya new one.????When the terminal has a problem withreading the label:The resolution of the bar code is too high.Decrease the distance between the bar code and the terminal.The angle between the label and the terminal is too high.Change the angle between the bar code and the terminal.The distance is too far or too close.Change the distance between the bar code and the terminal.The bar code is larger than the laser beam.Try moving the terminal a bit further away from the bar code.The read window is dirty.Clean the read window of the terminal.The type of the bar code label is not enabled.Enable the bar code symbology in the application program.??????USER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLE20This chapter contains information on solvingproblems you may encounter when using theterminal and/or cradle. If problems occur, firstcarry out some general checks, beforeverifying the problem with the descriptions inthis chapter.General checks:Make sure everything is installed properlyCheck the power supply of all devices Is the reading window of the terminal clean?Is the optical window of the cradle clean?Are the bar code labels readable, eg. not damaged or poorly printed?If the equipment still does not work after thesechecks have been performed, please verify ifone of the problems described in this chapterapplies to the problem you have with thescanner.It is possible that you may not solve the problems, despite our descriptions. In thisinstance, please contact your dealer orOpticon.When the terminal needs to be repaired,please ensure that the label with the serialnumber is still present. If sending the terminalor cradle, please use the original packing tominimise the chances of damage.TROUBLESHOOTING377.1   COMMUNICATIONPROBLEMS 7.2   READ OPERATION PROBLEMS
Opticon user's manualUSER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLE23Apart from the terminal, additional itemsmight be ordered.Article CodeTerminal PHL 2700-80 (8MB) A73800R0040Battery pack for terminalRechargeable Battery Pack O2540000020Dry Cell Battery Pack Assy O2510000030(assy = case holder + penlite batteries)Battery Case Holder Q2510000040Penlite Batteries PBA30000010Cable for terminalRS232 cable DB 9 female O2500000050Protective bags for terminalLeather bag O2510000055Leather bag clip O2510000060Software development toolsMicrotec ANSI-C cross compiler O8010000010C-library for handheld terminals D4030000020Application GeneratorPotstar Limited D6010000010Application GeneratorPotstar Professional D6020000010USER’S MANUAL PHL2700 TERMINAL / IRU2700 CRADLE22PRODUCTORDERINGINFORMATION38Apart from the cradle, additional itemsmight be ordered.Article CodeCradle IRU2700-S O2540000015Power supply for cradle9V DC adaptor  A50200N0020Cables for cradleRS232 cable DB 9 female O2520000020Adapter DB25 female/DB9 male P10AT000040RS485 cable O2520000050Terminal does not respond to key presses,while the display stays on.Message “Application halted”or “No application installed”is shown.There is no user’s application for PHL2700 loaded in the terminal. Contact your supplier.For example pressing the shift key does not toggle the shift indicator.There is a flaw in the application program.Disconnect the battery pack, and place it then back in.The terminal will be in off-state.Activate the system menu and restart the application, or download new application.If problems appears continously contact the supplier of the user’s application.Laser stays off, when pressing thetriggerkey.Power is off.The triggerkey is no powerkey. Press the powerkey to get power.If the terminal is not used the scanner will switch off all functions.Press the powerkey to reactivate.Laser temperature has become too high.The laser is switched off automatically, when thelaser temperature becomes above 50oC. Wait until the temperature has dropped.????Terminal gets no power, when pressing the powerkey.The main battery is exhausted.Replace the battery pack, or charge theterminal in the cradle.Terminal does still not operate and needs aserviceSend the terminal to your supplier for service,paying attention to the limited warranty.?7.3   TERMINAL PROBLEMS
Opticon user's manual24Opticon Article CodeO0220000022