Opticon Sensors Europe PHL7100-BW Portable Data Terminal User Manual Manual Part 8
Opticon Sensors Europe BV Portable Data Terminal Manual Part 8
Contents
Manual Part 8
OPTICON User's manual PHL-7000 series Figure 3-70 Network and Dial-up Figure 3-71 Network and Dial-up Connections Connections 3-40 OPTICON User's manual PHL-7000 series 3.2.12 Owner ICON ITEM & FUNCTION • ü ü ü • ü “Identification” Tab : (Figure 3-74) Fill in or edit the data as desired. To have this information displayed when you start your device, select “Display Owner Identification” at Power On. To set up identification for remote networks, see Setting up identification for remote networks. “Network ID” Tab: (Figure 3-75) Enter the user name, password, and domain name you use to log on to remote network. Table 3-32 Owner Figure 3-72 Owner Properties Figure 3-73 Owner Properties 3-41 OPTICON User's manual PHL-7000 series 3.2.13 Password ICON ITEM & FUNCTION • “Password Setting” Tab : (Figure 3-76) ü Enter the password ü In the “Confirm password “box, enter the password again. To require the password on startup, select “Enable password protection at power- on“. and/or select “Enable password protection for screen saver” To exit the Password control panel, press “OK” from the control bar, or press thekey on the keypad. ü ü Table 3-33 Password Figure 3-74 Password Properties 3-42 OPTICON User's manual PHL-7000 series 3.2.14 PC Connection ICON ITEM & FUNCTION • ü ü ü ü “PC Connection” Tab : (Figure 3-77) Select the first checkbox to enable direct connections to the desktop computer. (Figure 3-77) Tap the “Change Connection… ” button to modify the connection method from USB or Serial. (Figure 3-78) To exit the “Change Connection” dialog, press “OK” from the control bar, or press the key on the keypad. To exit the “PC Connection” properties control panel, press “OK” from the control bar, or press the key on the keypad. Table 3-34 PC Connection Figure 3-75 PC Connection Figure 3-76 PC Connection 3-43 OPTICON User's manual PHL-7000 series 3.2.15 Power ICON ITEM & FUNCTION • ü ü ü ü ü • ü ü ü “Battery” Tab : (Figure 3-79) Provide change level indicators for Main battery and Backup battery. Provide remaining power capacity of main battery. If a “Main Batteries very Low” warning message shows, the remaining battery life is around 30 minutes before PDT shuts down. ( Figure 3-83) The PDT will shutdown if the main batteries capacity is around 0% To exit Battery control panel, press “OK” from the command bar, or press key on keypad. “ Schemes” Tab: (Figure 3-80) The Scheme Tab allows you to determine the time to switch state to Suspend mode when using either Battery Power or AC Power. Select Battery Power or AC Power as the power scheme from the pull-down list.( Figure 3-80) Select the time to suspend mode from the pull-down list. ( Figure 3-81) • “Device Status” Tab: ( Figure 3-82) Provide power level of the device – The power level ranges from “ High(D0)” which means the device is at the highest power level to “Off(D4)” which means the device is at the lowest power level. Note: This ICON inside the Task Bar shows that AC adapter provides power to the PDT The ICON inside the Task Bar shows that Main Batteries provides the power to the PDT. The ICON inside the Task Bar shows that AC adapter provides the power to the PDT and is charging the main batteries.. Table 3-35 Power 3-44 OPTICON User's manual PHL-7000 series Figure 3-77 Power Figure 3-78 Power Figure 3-79 Power Figure 3-80 Power Figure 3-81 Power 3-45 OPTICON User's manual PHL-7000 series 3.2.16 Regional Settings ICON ITEM & FUNCTION • “Region” Tab : (Figure 3-84) ü Select the desired location/language. ü Review the Appearance samples in the bottom half of the screen. Select the Tab at the top for any settings you wish to ü change, Options to modify include Number, Currency, Time, and Date. Table 3-36 Regional Settings Figure 3-82 Regional Settings 3-46 OPTICON User's manual PHL-7000 series 3.2.17 Remove Programs ICON ITEM & FUNCTION • ü Ø “Remove Programs” Tab : Only user installed programs can be removed. Select the program you wish to remove from the list and press “remove” button. Table 3-37 Remove Programs 3.2.18 Storage Manager ICON ITEM & FUNCTION • “Storage Manager” Tab : (Figure 3-83) To change Storage properties control panel default settings: Insert Compact Flash(CF) or Secure digital (SD) storage card into the unit. ü Ø Ø Select Start > Settings > Control Panel > Storage Properties From the “Storage Info” pull-down list, select the desired storage device. Ø You can also format, dismount, and create partitions on storage devices using this control panel. Ø To save and exit the Storage Properties control panel, press “OK” from the control bar, or press the key on the keypad. Caution: Dismounting or formatting the DiskOnChip will erase all files and program stored in Flash Memory Table 3-38 Storage Manager 3-47 OPTICON User's manual PHL-7000 series Figure 3-83 Storage Manager 3.2.19 Stylus ICON ITEM & FUNCTION • ü ü ü ü • “Double-Tap” Tab : (Figure 3-86,Figure 3-87) Double-tap the checkerboard grip at a comfortable speed. Double-tap clapboard to test your settings. The function is OK if the figures are changed from Figure 3-86 to Figure 3-87. To tap “OK” to exit the Stylus Properties. “Calibration”: (Figure 3-88, Figure 3-89) ü In the Welcome Wizard, you tapped a target with the stylus to set the amount of pressure needed for the screen to respond to your stylus taps. ü Please also see 2.4.3 Calibration of the touch Screen Table 3-39 Stylus 3-48 OPTICON User's manual PHL-7000 series Figure 3-84 Stylus Properties Figure 3-85 Stylus Properties Figure 3-86 Stylus Properties Figure 3-87 Stylus Properties 3-49
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V2.3 (128-bit) User Access : Print, Copy, Print high-res XMP Toolkit : 3.1-702 Modify Date : 2006:12:01 09:04:59-08:00 Create Date : 2006:12:01 09:01:47-08:00 Metadata Date : 2006:12:01 09:04:59-08:00 Creator Tool : PHL-7x00 User Manual_EN-20061201--(without GSM)-rev - Microsoft Word Format : application/pdf Title : PHL-7x00 User Manual_EN-20061201--_without GSM_-rev.doc Creator : joy Document ID : uuid:dde5af9f-f12c-42dc-b5b1-41928cc708eb Instance ID : uuid:7f5beee4-78b6-4653-9d8c-ca5186ae38df Producer : Acrobat PDFWriter 5.0 for Windows NT Page Count : 10 Author : joyEXIF Metadata provided by EXIF.tools