Oregon Scientific Cable Free Wmr968 Users Manual
WMR968 to the manual 0454970c-89eb-4cfa-bf7b-1031edde1926
2015-02-04
: Oregon-Scientific Oregon-Scientific-Cable-Free-Wmr968-Users-Manual-374473 oregon-scientific-cable-free-wmr968-users-manual-374473 oregon-scientific pdf
Open the PDF directly: View PDF
.
Page Count: 9
| Download | |
| Open PDF In Browser | View PDF |
GB CABLE FREETM WEATHER STATION SECTION 2 INSTALLATION The WMR968 operates at 433MHz. No wire installation is required among units. MODEL: WMR968 The WMR968 has an effective range of 109 yards in an open area. Position the units within the range and be sure the transmission path is clear of interference and obstacles. USER’S MANUAL SECTION 1 INTRODUCTION Note:The anemometer, thermo-hygrometer and rain gauge should be installed outdoors and in locations that best measure the weather elements the instruments are designed for. As for the baro-thermohygrometer, it must be installed indoors. If you have any optional thermo or thermo-hygro sensors, they can be installed outdoors or indoors. Congratulations on your purchasing the WMR968 Cable FreeTM Weather Station. An all-purpose easy-to-use system, the WMR968 lets you monitor the following weather elements: - Air temperature - Relative humidity - Barometric pressure - Wind speed and direction - Rainfall The WMR968 is also equipped with: - Calendar clock with daily alarm - Weather forecast within 32 to 48 km (20- to 30-mile) radius - Weather alarms - Memory for maximum and minimum readings - Simple, touch-screen operation - RS232 PC connection jack - backlight STANDARD PACKAGE The original WMR968 comes complete with the following: - Main unit (WMR968) - Anemometer (WGR968) - Thermo-hygrometer (THGR968) - Rain gauge (RGR968) - Baro-thermo-hygrometer (BTHR968) - 12V AC adapter The thermo-hygrometer and rain gauge are powered by solar transmitters STR928 while the anemometer is powered by solar transmitter STR938. The WMR968 can support up to seven different remote instruments. You can also connect up to three optional thermo or thermo-hygro sensors to the system. The anemometer measures wind speed and direction. Optional items include: To install it, - Thermo-hygro sensor (THGR238) 1. Place the wind cup over the thinnest shaft on the anemometer’s T-bar. THE ANEMOMETER - Thermo sensor (THR238) Contact an authorized dealer for optional items. 2. Tighten the screw on the base of the wind cup. 1 928N-USE.p65 1 08/10/2001, 12:20 PM GB 3. Mount the rain gauge and its solar transmitter safely in place. 3. Align the red markings on the wind vane’s shaft. 4. Put drops of water on the cross at the base on the rain collector to check the leveling. Water stay at position 1 - 4 means the gauge is not leveled 4. With the aid of a compass, face the red marking south before mounting the anemometer. 5. Use metal ring to adjust the leveling of the rain collector if necessary. METAL RING 6. Close the cover of the rain collector. 5. Mount the anemometer and its solar transmitter safely in place. THE SOLAR TRANSMITTERS The solar transmitters make use of solar energy to power the instruments they are connected to. Note: It is recommended to insert two UM3 or “AA”-sized super lithium batteries for weather condition under 0 °C (32 °F). For the solar transmitters to function properly, make sure the solar receptors on the transmitters are exposed to sunlight and the connectors of the connection cable are securely plugged in. The wind speed and direction window on the main unit should read 180° if the main unit is installed. THE THERMO-HYGROMETER The thermo-hygrometer measures outdoor temperature and humidity. To install it: Mount the thermo-hygrometer and its solar transmitter safely in place. THE BARO-THERMO-HYGROMETER The baro-thermo-hygrometer measures the atmospheric pressure, temperature and humidity. The sensor uses four UM4 or “AAA”-sized batteries. To install it, 1. Insert alkaline batteries accordingly. THE RAIN GAUGE The rain gauge measures the total amount and rate of rainfall. To install it: 1. Open the cover of the rain collector. 2. Remove the fiber tape from around the bucket assemblies. 2. Mount the unit where you want to monitor the readings. Or you can make use of its table stand to place it on a flat surface. 2 928N-USE.p65 2 08/10/2001, 12:20 PM GB THE MAIN UNIT SECTION 3 OPERATION The main unit gives you all the readings and controls. It should be placed indoors. THE MAIN UNIT The main unit is powered up by the 12V AC adapter. To install it, 1. Position the main unit and other units within effective range (109 yards). 2. Insert four UM3 or “AA”-sized alkaline batteries for backup purpose. 3. Mount the main unit safely in place. Or use its table stand to place it on a flat surface. 4. Connect the AC power adapter to the main unit and a wall socket. 5. Press the [RESET] button on the main unit to initiate operation. The main unit will start searching for signals for about four minutes. Upon successful reception, the readings will be displayed. The main unit will update the readings at regular intervals. Note: That if the main unit is operating solely on battery power, the EL backlight and RS232 connection will be disabled. A. WEATHER FORECAST AND BAROMETRIC READING WINDOW B. INDOOR TEMPERATURE WINDOW C. INDOOR HUMIDITY WINDOW D. OUTDOOR/CHANNEL TEMPERATURE WINDOW E. OUTDOOR/CHANNEL HUMIDITY WINDOW F. RAINFALL WINDOW G. CALENDAR CLOCK AND DAILY ALARM WINDOW H. WIND SPEED AND DIRECTION WINDOW I. CHANNEL BUTTON J. MEMORY BUTTON K. ALARM BUTTON L. SET BUTTON M. UNIT BUTTON LOW-BATTERY WARNING ] for the main unit, rain There are low-battery indicators [ gauge, baro-thermo-hygrometer, thermo-hygrometer and optional remote thermo and thermo-hygro sensors. Replace the batteries when the respective indicators light up. N. ALARM ON/OFF BUTTON O. [U ] BUTTON P. [V] BUTTON Q. [ RESET] BUTTON R. RS232 SERIAL PORT S. DC 12V JACK Note: The readings collected from the thermo-hygrometer and any optional remote thermo and thermo-hygro sensors share the same display window. The “OUT” and remote channel will share the same low-battery indicator. When the battery level of the thermohygrometer is low, the low-battery indicator will turn on. If it is one of the optional remote sensors, the low-battery indicator will blink. To locate the channel in question, press the window to scan through all available devices. The low-battery indicator will stop blinking if the battery level is low for that one. 3 928N-USE.p65 3 08/10/2001, 12:20 PM GB 5. Press [SET] for minutes setting. BACKLIGHT 6. Use [U] and V] to change to the desired setting. The main unit, when connected to the AC power, is equipped with an automatic backlight. Every time you press a window on the main backlight will come on for a few seconds. This unit, the 7. Press [SET] to confirm. Note: the window will show “ function will be disabled for sole battery operation. The backlight will also come on for a few seconds when the alarm is triggered. ” if no alarm is armed. Once set, the alarm clock will be activated automatically and the alarm indicator will light up. When an alarm goes off, press any button to stop it. The alarm is still active and will go off again the next day. To deactivate the function, CALENDAR CLOCK 1. Press the calendar clock and alarm window. To set the calendar clock, 2. Press [ALARM ON/OFF]. The alarm indicator 1. Press the calendar clock and alarm window. 2. Press and hold [V] to disable the radio reception function. will disappear. WEATHER FORECAST 3. Press and hold [SET] till the digit flash. The weather forecast is displayed in the weather forecast and barometric reading window. 4. Use [U] and [V] to change to the desired setting. 5. Press [SET] for the next item setting. There are four readings for the forecast: sunny, slightly cloudy, cloudy and rainy. 6. Repeat from Step 4 to finish all the settings for: - Clock display formats (12hr or 24hr) Indicator displays on the unit - Display language of the day-of-the-week - Clock Forecast - Calendar display formats (Month-Day, Day-Month) Sunny Slightly Cloudy Cloudy Rainy - Calendar For the display language, you can choose: INDOOR BAROMETRIC READING - English (E) The atmospheric pressure reading is displayed in the weather forecast and barometric reading window. - German (D) - French (F) - Italian (I) The pressure reading can be displayed in mb (millibars), hPa (Hecto-Pascal), inHg (inch mercury) or mmHg (millimeter mercury). - Spanish (S) To select the display unit, 7. Press [SET] to confirm. 1. Press the weather forecast and barometric reading window. The calendar clock and alarm window has three displays: clock with seconds, clock with day-of-the-week and calendar. To change from one display to another, press the window once. 2. Press [UNIT] repeatedly for the desired setting. The pressure history for the past 24 hours is displayed in a sixcolumn bar chart. The calendar clock also supports the following time zones: - Pacific time (P) To display the pressure reading for a particular hour within the past 24 hours, - Mountain time (M) 1. Press the weather forecast and barometric reading window. - Central time (C) 2. Press [U] and [V] for the desired hour. - Eastern time (E) To set the sea-level pressure, To select a time zone, 1. Press and hold the calendar clock and alarm window. 1. Press the weather forecast and barometric reading window repeatedly till the “sea-level” icon is displayed. 2. Press [U] and [V] for the current (0 Hr) pressure. 2. Press [U] and [V] to change. 3. Press and hold [SET]. 3. Press the window again to confirm. 4. Press [U] and [V] to change to the desired setting. THE DAILY ALARM 5. Press [SET] to confirm. To set the daily alarm, INDOOR AND DEW POINT TEMPERATURES 1. Press the calendar clock and alarm window. 2. Press [ALARM] and the you are in the alarm mode. indicator will be display to indicate The current indoor and dew point temperatures, taken by the indoor baro-thermo-hygrometer, are displayed on the indoor temperature window. They can be displayed in degree Centigrade (ºC) or Fahrenheit (ºF). 3. Press and hold [SET] till the hour digit flash. 4. Use [U] and [V] to change to the desired setting. 4 928N-USE.p65 4 08/10/2001, 12:20 PM GB The temperatures can be displayed in degree Centigrade (°C) or Fahrenheit (°F). To select the display unit, 1. Press the indoor temperature window. 2. Press [UNIT] repeatedly for the desired setting. The selected unit will apply to all temperature displays in this window. To select the display unit, Note: The unit of all temperature related display will be changed simultaneously. 2. Press [UNIT] repeatedly for the desired setting. The selected unit will apply to all temperature displays in this window. To display the dew point temperature, press the indoor temperature window until the “DEW” indicator is displayed. Note: The unit of all temperature related display will be changed simultaneously. To display maximum, minimum temperatures, To display the maximum, minimum temperatures, 1. Press the indoor temperature window or repeately until "DEW" icon appear. 1. Press the outdoor/channel temperature window or repeately until "DEW" icon appear. 2. Press [MEMORY] repeatedly for the desired record. The time and date of the record will also be displayed alternatively with “STAMP” icon in the clock window. 2. Press [CHANNEL] for the outdoor thermo-hygrometer or the desired channel. 1. Press the outdoor/channel temperature window. 3. Press [MEMORY] repeatedly for the desired record. The time and date of the record will also be displayed alternatively with “STAMP” icon in the clock window. To display the dew point temperature for a channel, press the window again when the channel temperature is located. The display will automatically return to the current temperature or dew temperature whatever is displayed before if the unit is left untouched for about one minute. To clear the memory, To clear the memory, 1. Press the outdoor/channel temperature window or repeately until "DEW" icon appear. 1. Press the indoor temperature window or repeately until "DEW" icon appear. 2. Press and hold [MEMORY] till the key tone is heard. 2. Press [CHANNEL] for the outdoor thermo-hygrometer or the desired channel. 3. Press [MEMORY] to check the memory is clear. 3. Press and hold [MEMORY] till the key tone is heard. 4. Press [MEMORY] to check the memory is clear. INDOOR HUMIDITY The current indoor relative humidity, taken by the indoor barothermo-hygrometer, is displayed on the indoor hygrometer window. OUTDOOR AND CHANNEL HUMIDITY The relative humidity readings taken by the outdoor thermohygrometer and separate thermo-hygro sensors are displayed on the outdoor/channel humidity window. To display the maximum, minimum and current humidity, 1. Press the indoor humidity window. 2. Press [MEMORY] repeatedly for the desired record. The time and date of the record will also be displayed alternatively with “STAMP” icon in the clock window. As this window can display up to four different sets of data, specify the instrument or channel you want to read. To clear the memory, 1. Press the outdoor/channel humidity window. To do so, 1. Press the indoor humidity window. 2. Press [CHANNEL] to go from the outdoor reading taken by the thermo-hygrometer to those taken by individual sensors (Channel 1, 2 or 3). 2. Press and hold [MEMORY] till the key tone is heard. 3. Press [MEMORY] to check the memory is clear. To display the maximum, minimum and current humidity, 1. Press the outdoor/channel humidity window. OUTDOOR AND CHANNEL TEMPERATURES 2. Press [CHANNEL] for the outdoor thermo-hygrometer or the desired channel. The temperature readings taken by the outdoor thermo-hygrometer and separate thermo or thermo-hygro sensors are displayed on the outdoor and channel temperature window. 3. Press [MEMORY] repeatedly for the desired record. The time and date of the record will also be displayed alternatively with “STAMP” icon in the clock window. As this window can display up to four different sets of data, specify the instrument or channel you want to read. To clear the memory, To do so, 1. Press the outdoor/channel humidity window. 1. Press the outdoor/channel temperature window. 2. Press [CHANNEL] for the outdoor thermo-hygrometer or the desired channel. 2. Press [CHANNEL] to go from the outdoor reading taken by the outdoor thermo-hygrometer to those taken by individual sensors (Channel 1, 2 or 3). 3. Press and hold [MEMORY] till the key tone is heard. 4. Press [MEMORY] to check the memory is clear. The outdoor thermo-hygrometer is also capable of detecting the dew point temperature as well as the wind chill reading. To display such information, press the window repeatedly. 5 928N-USE.p65 5 08/10/2001, 12:20 PM GB To clear the record, AUTO SCANNING FUNCTION 1. Press the wind speed and direction window. The auto scanning function is avalibable for the outdoor/channel window for both the temperature and humidity. 2. Press and hold [MEMORY]. To use it, As for the wind direction, it is displayed in a digital compass with bearing readouts. 1. Press the outdoor/channel temperature or humidity window. 2. Press and hold [U] . The main unit will start scanning from the active temperature and humidity display. Each channel will be displayed for about 4 seconds. WEATHER ALARMS Weather alarms are used to alert you to certain weather conditions. Once activated, the alarm will go off when a certain set criterion is met. To exit the auto scanning routine, press any window or control button. You can set alarms for: · Indoor, outdoor and channel high temperatures RAINFALL · Indoor, outdoor and channel low temperatures The rate of rainfall can be displayed in mm/hr or in/hr. · Indoor, outdoor and channel dew point approaching To select the display unit, 1. Press the rainfall window. · Indoor, outdoor and channel high humidity 2. Press [UNIT] for the desired setting. · Indoor, outdoor and channel low humidity To display the yesterday’s rainfall and the total rainfall from the last cleared date, · High rainfall rate 1. Press the rainfall window. · High gust wind 2. Press [MEMORY] for the desired record. Yesterday rainfall will be displayed with “YESTERDAY” shown in the rainfall window. Total rainfall will be displayed with "TOTAL" shown in the rainfall window. The time and date of the record will be displayed alternatively with “SINCE” icon in the clock window for total rainfall. · Low wind chill · Pressure drop To set a weather alarm, 1. Press the window containing the weather element you want to set. 2. Press [ALARM]. The current alarm setting will be displayed. 3. Press and hold [SET]. Note: Yesterday’s rainfall record will be updated when the real time clock runs from 11:59:59 pm to 12:00:00 am. And it is counted for 12:00:00 am of one day to 12:00:00 am on the next day. 4. Press [U] and [V] for the desired setting. 5. Press [SET]. If the rain sensor detects no rainfall for about two consecutive hours, the current rate of rainfall will be displayed as zero. For temperatures and humidity, the high and low alarms can be set in sequence. After entering the value for one alarm, you will be prompted to enter the value for the other. To clear the total rainfall, A weather alarm is activated once set. When the set criteria is met, an alarm will go off and the current reading will flash together with the corresponding indicator. 1. Press the rainfall window. 2. Press and hold [MEMORY] till the key tone is heard. The yesterday’s rainfall record will not be affected when you clear the total rainfall. If that happens in the outdoor/channel temperature or humidity window, the “OUT” indicator will flash to show that the criteria set for the outdoor thermo-hygrometer has been met. If it is one of the separate sensors, the [CHANNEL] indicator will flash. Press the window repeatedly to locate the channel in question. WIND SPEED AND DIRECTION The current wind speed and direction are displayed in the wind speed and direction window. When a weather alarm goes off, press any button to stop the alarm. The alarm is still active until you deactivate the function or the criteria is no longer met. To display the average wind speed, press the window till the “AVERAGE” icon is displayed. To do so, The wind speed can be displayed in m/s, kph, mph or knots. To select the display unit, 1. Press the window containing the weather element you want to set. 1. Press the wind speed and direction window. 2. Press [ALARM]. 2. Press [UNIT] for the desired setting. 3. Press [ALARM ON/OFF] to deactivate the function. To display the maximum speed and direction for gust wind in record, To turn on the function again, simply follow the same procedure and press [ALARM ON/OFF]. 1. Press the wind speed and direction window. 2. Press [MEMORY]. The time and date of the record will also be displayed aternatively with “STAMP” icon in the clock window. 6 928N-USE.p65 6 08/10/2001, 12:20 PM GB ( -4°F to 140°F ) DISCONNECTED SIGNALS Resolution (indoor and outdoor) If without obvious reason the display for the main unit goes blank ” are displayed, press and hold [CHANNEL] to enforce an or “ immediate search. : 0.1°C (0.2°F) Relative Humidity Measuring Range (indoor and outdoor) If that fails, check: - All weather instruments are still in place. : 2 to 98% RH Resolution (indoor and outdoor) - The batteries of the main unit and individual weather instruments are still good. Replace them if necessary. Press and hold [CHANNEL] to enforce an immediate search afterwards. : 1% RH Dew Point Temperature Measuring Range - The transmission is within range and path is cleared of obstacles and interference. Shorten the distance if necessary. Then press and hold [CHANNEL] again. The main unit will start searching for all previously locked weather instruments. : Indoor ..... 0°C to 49°C ( 32°F to 120.2°F ) : Outoor ..... -10°C to 60°C ( 14°F to 140°F ) Resolution (indoor and outdoor) If you want to add an new sensor, press the reset button on the new sensor and then press channel to enforce the main unit to search. Note: 1. Do not reset the sensors after the main unit has locked those sensors, otherwise the main unit will no longer receive the signal from those sensors. : 1°C (2°F) Barometric Pressure / Trend Measuring Range : 795 to 1050 mb (23.48 to 31.01 inHg) Resolution : 1 mb (0.03 inHg) 2. If you have disconnected signals, you cannot clear the memory. THE RESET BUTTON This button is only used when the system is operating in an unfavorable way or malfunctioning. Use a blunt stylus to hold down the button. The main unit will return to all default settings and start searching for signals again. Before resetting the main unit, you should do the same for all weather instruments to ensure correct transmission and reception of signals. Then press reset on the main unit. Wind Speed Measuring Range Resolution : 0 to 56 m/s (0 to 125.3 mph) : 0.2 m/s (0.4 mph) (typical) Wind Direction Measuring Range Digital Resolution Graphical Resolution : 0° to 359° (Degrees) : 1° (typical) : 10° Wind Chill Temperature Measuring Range : -52°C to 60°C (-61.6°F to 140°F) Resolution : 1°C (2°F) MAINTENANCE When handled properly, this unit is engineered to give you years of satisfactory service. Here are a few product care instructions: 1. Do not immerse the unit in water. If the unit comes in contact with water, dry it immediately with a soft lint-free cloth. Rainfall Daily and Cumulative 2. Do not clean the unit with abrasive or corrosive materials. Abrasive cleaning agents may scratch the plastic parts and corrode the electronic circuit. Measuring Range 3. Do not subject the unit to excessive: force, shock, dust, temperature, or humidity. Such treatment may result in malfunction, a shorter electronic life span, damaged batteries, or distorted parts. : 0 to 9999 mm (0 to 393.7 in) Rainfall Rate Measuring Range : 0 to 999 mm/hr (0 to 39.37 in/hr) Daily and Cumulative Resolution : 1 mm (0.04 inch) Rainfall Rate Resolution : 1mm/hr (0.04 m/h) typical 4. Do not tamper with the unit’s internal components. Doing so will terminate the unit’s warranty and may cause damage. The unit contains no user-serviceable parts. 5. Only use new batteries as specified in this instruction manual. Do not mix new and old batteries as the old batteries may leak. 6. Read this instruction manual thoroughly before operating the unit. SPECIFICATIONS Temperature Proposed Operating Range : Indoor ..... -5°C to 50°C ( 23°F to 122°F ) : Outoor ..... -20°C to 60°C WMR968 : Weight Dimension Power Power backup : : : : WGR968 : Weight Dimension Power : 430 g : 295 (L) x 116.5 (W) x 550 (H) : solar cell (STR918) 505 g 204 (L) x 139 (W) x 39 (H) 12V AC / DV adapter 4 x UM3 - “AA” size alkaline battery 7 928N-USE.p65 7 08/10/2001, 12:20 PM GB R&TTE Compliance Note THGR968 : Weight Dimension Power : Main : 111.5 g : 113.5 (L) x 42.5 (W) x 107.5 (H) : solar cell (STR918) RGR968 : Weight Dimension Power : Main : 276 g : Ø 113.5 x 145 (H) : sole cell (STR918) BTHR968 : Weight Dimension Power : 78.4 g : 180 (L) x 70 (W) x 19 (H) : 4 x UM4 - “AAA” size alkaline battery STR928 : Weight Dimension Power back up STR938 : Weight Dimension Power back up This device complies with the essential requirements of Article 3 of the R&TTE 1999/5/EC Directive, if used for its intended use and that the following standard(s) has been applied: Electromagnetic compatibility (Article 3.1.b of the R&TTE Directive) Applied standards ETS 300 683 : 1997 Efficient use of the radio frequency spectrum (Article 3.2 of the R&TTE Directive) Applied standards EN300 220 –1 : 1997 INTENDED USE OF THE DEVICE : 266 g : 115 (L) x 81 (W) x 138 (H) : 2 x UM3- “AA” size alkaline battery (recommend super lithium battery for weather condition under 32°F) CAUTION — The content of this manual is subject to change without further notice. : 290 g : 115 (L) x 81 (W) x 138 (H) : 2 x UM3- “AA” size alkaline battery (recommend super lithium battery for weather condition under 32°F) — Due to printing limitation, the displays shown in this manual may differ from the actual display. — The contents of this manual may not be reproduced without the permission of the manufacturer. NOTE ON COMPLIANCE Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC : NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is needed. Consult the dealer of an experienced radio/TV technician for help. 8 928N-USE.p65 8 08/10/2001, 12:20 PM GB CUSTOMER ASSISTANCE Should you have questions about this project or require additional assistance, please contact our 24-7-365 customer service department at 800-853-8883 or via email at helpme@oscientific.com. Product Name : CABLE FREE WEATHER STATION Model Number : WMR968 Responsible Party : Oregon Scientific, Inc.19861 SW 95th Place Tualatin, Oregon 97062 USA Tel : 503-639-8883 9 928N-USE.p65 9 08/10/2001, 12:20 PM
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2001:08:10 12:20:44Z Modify Date : 2001:09:28 15:19:36-06:00 Page Count : 9 Creation Date : 2001:08:10 12:20:44Z Producer : Acrobat Distiller 4.0 for Windows Mod Date : 2001:09:28 15:19:36-06:00 Metadata Date : 2001:09:28 15:19:36-06:00EXIF Metadata provided by EXIF.tools