Orpak Systems 800960000 Fuel Pump Nozzle Reader NNR + Switch User Manual 817460005 Rev A nNR Assembly Guide
Orpak Systems Ltd. Fuel Pump Nozzle Reader NNR + Switch 817460005 Rev A nNR Assembly Guide
Contents
- 1. Users Manual
- 2. User Manual
Users Manual
![Parameter ValueSupply Voltage 3.6 internal battery pack P/N 812560010Power Consumption Active Mode: 160mA Standby Mode 20 μAOperating Temperature -40° to +60° CStorage Temperature -40° to +85° CIP Rating IP 67Dimensions (HxWxD) 41x84x60.5mmWeight 132gCommunication Interface RF to WGT: 2.405-2.480GHz Typical transmission power: 3dbm (2mW) RFID to FuelOpass: 108-131 kHz Zone 1 Expl osive atmospher e (Ex) ia (intri nsic safety) protection level Gr oup IIC type product TemperatureClass:T6 Rated Tem peratur es:- 40°< Tamb< +60° C SpecificationsThe FCC Wants You to Know:This equipment has been tested and found to comply with the limits for a Class A & B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures :a) Reorient or relocate the receiving antenna.b) Increase the separation between the equipment and receiver.c) Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.d) Consult the dealer or an experienced radio/TV technician.Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with FCC Rules Part 15 and with Industry Canada licence-exempt RSS standard(s). Operation is subject to two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference that may be received or that may cause undesired operation. Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisee aux deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement.FCC Compliance Statement WarningUniversal KitnNR universal kit suits any spout diameter between 22mm and 32mm as it includes 4 grip kits. Choose your grip kit according to the table below:Husky 1A 30 6Husky X 27 6OPW 11 A/B Leaded 30 6OPW 11 A/B Unleaded 27 6OPW Avance HS/VR 32 6OPW DEF 27 6Tatsuno Leaded 30 6Tatsuno Unleaded 27 6ZVA 25 32 6ZVA DEF 24 8ZVA Slim Line 30 6ZVA S.L. 2-GR 30 6 Nozzle Model Grip Kit** Set Screws**Use 10mm set screws when spout diameter is 22mm or below.** The 32mm grip kit includes only a two-pieces top lid instead of two lids.FOR SUCCESSFUELING YOUR BUSINESSnano Nozzle ReaderAssembly GuideHazardous AreaWatch nNR Installation TutorialP/N 817460005](https://usermanual.wiki/Orpak-Systems/800960000.Users-Manual/User-Guide-2482630-Page-1.png)
![Slide the adaptor over the spout. Place it as close as possible to thenozzle bodyChoose the proper grip kit for the nozzle (see rear table). Place a lid, the rubber fillerand then the other lid Secure the gip kit with the M4 screws. Tighten them in stages and in a diagonal sequence. Use a 3mm head ratchetApply glue and place the set screws in the adaptor corners. Use a 2mm Allen key Slide the nNR assembly over the spoutSecure the nNR to the adaptor with the M3screws. Use a 2mm Allen keyPlace the nNR front cover on top of the assembly. Secure with the M3 screws. Use a 2mm Allen keyInstallation Kit1234567891 Set Screws 815221300 (6) 815221380 (8) 815221310 (10) 2 Spout Adaptor 8143605003 Lids 814360424 (24) 814160427 (27) 814160430 (30) 814360700 (32)4 Rubber Filler 814160024 (24) 814160027 (27) 814160030 (30) 814160032 (32)5 M4 Screws 8152134246 nNR Assembly 819260000 (nNR)/819260100(nNR + Switch)7 M3 Screws 8152603008 Front Cover 8143602009 M3x6 Screws 815260200# Part Name Part Number 3Required Tools2mm standard Allen key (not ball ended)3mm Allen head ratchet (not ball ended)Loctite 222/Holdtite T43 glue Unit should be serviced only by authorized service personnel.Program the unitOpening of the unit by Service Personnelmust not be done at the location of installation.When replacing the battery, use only P/N 812560010. Installation Notes123456783mm2mm2mm2mm412141412 Qty.](https://usermanual.wiki/Orpak-Systems/800960000.Users-Manual/User-Guide-2482630-Page-2.png)