Oticon A S WLPS10 WLP Special User Manual COMPANY LETTER HEAD

Oticon A/S WLP Special COMPANY LETTER HEAD

InstallationInstructions.pdf

Download: Oticon A S WLPS10 WLP Special User Manual   COMPANY LETTER HEAD
Mirror Download [FCC.gov]Oticon A S WLPS10 WLP Special User Manual   COMPANY LETTER HEAD
Document ID2237737
Application IDjcwWA/5iEmWQdvLUwz8x6Q==
Document DescriptionInstallationInstructions.pdf
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize33.43kB (417935 bits)
Date Submitted2014-04-10 00:00:00
Date Available2014-07-09 00:00:00
Creation Date2017-10-23 07:11:23
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-10-23 07:11:23
Document Title< COMPANY LETTER HEAD>
Document CreatorMicrosoft® Word 2010
Document Author: PC-8726

PEOPLE FIRST
Oticon Radio Model - Quick Installation Guide
Radio Model Name:
WLP Special
The WLP Special Radio Module is a module intended for WireLess Programming devices (WLPs) and completely equipped with both a microprocessor host and a
short range low power radio system on board the same Printed-Circuit-Board (PCB). Besides the host and the radio system the module also includes a power
management circuit, EEPROM memory, USB connector, battery connector, two neck loop connectors and small discrete components.
When the WLP Special radio module is mounted inside plastic shells for a wireless
programming device with a neck loop antenna attached, then the whole product shall
normally be placed on the neck of an end user with one or two wireless hearing aids on the
ears, also running at a radio frequency of 3.84 MHz. The end product shall be operated by a
trained hearing care professional via a PC with Oticon certified SW controlling the product
through an USB cable.
The radio system inside the module is a low power, inductive radio transceiver working at
3.84 MHz and consisting of (see illustrations next page):
- A radio transmitter controller
- A radio receiver circuit
- A frequency generating circuit and
- A 16 MHz crystal
The low power, inductive radio transmitter is consisting of a Complex Programmable Logic
Device (CPLD) fed with data from the host, a clock oscillator and two switching transistors
feeding the modulated RF signal at 3.84MHz to a dedicated neck loop antenna.
The module mounted inside a plastic shell and with its loop antenna attached is depicted to
the right:
NB: The WLP Special radio module is ONLY intended for Oticon and OEM branded products intended for wireless programming of hearing aids at
3.84 MHz. If used for other types of products or systems, Oticon cannot guarantee continued conformance with FCC part 15 regulations. Because of
this and due to limited shielding of the module, the WLP Special radio module is only approved with a limited modular approval.
Oticon A/S
Main +45 39 17 71 00
Kongebakken 9
Fax +45 39 27 79 00
DK-2765 Smørum
Denmark
www.oticon.com
CVR-no. 42334219
PEOPLE FIRST
Oticon Radio Model - Quick Installation Guide
Radio Model Name:
WLP Special
The WLP Special Radio Module with all its mounted components is
intended to be installed as a module into Oticons WireLess Programming
devices (WLPs), (e.g. the FittingLINK WP-1) or similar OEM branded
products (like Bernafon).
The module requires only a battery to be mounted together with its neck
loop antenna in an external plastic shell (as shown on the previous page).
The module requires no microphones or speakers as no sound only data is
streamed wirelessly to connected devices (e.g. Oticons wireless hearing
aids).
WLP Special Radio Module PCB (Top side)
The module has its power management subsystem including all voltage
regulators and the charging circuit on board. Also all data interfaces
(input-output) on the board are buffered.
The module PCB is depicted to the right with its main components and
connections:
WLP Special Radio Module PCB (Bottom side)
Oticon A/S
Main +45 39 17 71 00
Kongebakken 9
Fax +45 39 27 79 00
DK-2765 Smørum
Denmark
www.oticon.com
CVR-no. 42334219
PEOPLE FIRST
Oticon Radio Model - Regulatory Label Information
Radio Model Name:
WLP Special
Contains:
U28WLPS10
FCC ID:
NOTICE:
This device complies with Part 15 of the FCC Rules (hereunder §15.107/207, §15.109/209 and §15.223).
Operation is subject to the following two conditions:
(1)
This device may not cause harmful interference, and
(2)
This device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications made to this equipment not expressly approved by Oticon A/S may void the FCC authorization to operate this equipment.
Oticon A/S
Main +45 39 17 71 00
Kongebakken 9
Fax +45 39 27 79 00
DK-2765 Smørum
Denmark
www.oticon.com
CVR-no. 42334219

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Extract
Author                          : PC-8726
Create Date                     : 2014:04:08 13:02:55+02:00
Modify Date                     : 2014:04:09 15:04:45+02:00
Language                        : da-DK
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Creator                         : PC-8726
Title                           : < COMPANY LETTER HEAD>
Creator Tool                    : Microsoft® Word 2010
Metadata Date                   : 2014:04:09 15:04:45+02:00
Producer                        : Microsoft® Word 2010
Document ID                     : uuid:ccd31121-b454-4203-9b98-e442821a3d40
Instance ID                     : uuid:7247434d-58de-4b96-b9d2-479e7c3a3fba
Page Count                      : 3
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U28WLPS10

Navigation menu