Otodata Wireless Network C003 Telemetry - Wireless Modem User Manual CONFIDENTIAL AND PROPRIETARY

Otodata Wireless Network Inc. Telemetry - Wireless Modem CONFIDENTIAL AND PROPRIETARY

User Manual

Download: Otodata Wireless Network C003 Telemetry - Wireless Modem User Manual CONFIDENTIAL AND PROPRIETARY
Mirror Download [FCC.gov]Otodata Wireless Network C003 Telemetry - Wireless Modem User Manual CONFIDENTIAL AND PROPRIETARY
Document ID2966265
Application IDUYci7SGZhSCS99S2G6dN+Q==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize25.71kB (321361 bits)
Date Submitted2016-04-21 00:00:00
Date Available2016-04-22 00:00:00
Creation Date2016-03-28 16:13:26
Document Lastmod2016-03-28 16:13:26
Document TitleCONFIDENTIAL AND PROPRIETARY
Document Author: JMG

CONFIDENTIAL & PROPRIETARY
C003 v.0r1
Alarm panel
interface
radio communicator
USER MANUAL

SPRS Ready
 Self-contained
 Highly robust communication
protocol
The C003 Alarm panel interface radio communicator is a transceiver that is used primarily for
the communication of identification, control and management information from residential and
commercial alarm systems using RF (radio frequencies).
System description.
The C003 system has been developed with the goal of providing the following services.


Data transfer, logging and Telemetry
Full and Partial alarm CID reporting
The use of the C003 enables wireless data collection and reporting of CID alarm panel messages. This
monitoring and control is done according to schedules and specific conditions that have been previously
established.
The C003 was developed in order to minimize the use of space inside standard alarm panel enclosures.
One of the main criteria for the development was also reduced operating cost. This is achieved by virtue
of the fact that energy consumption is kept to a minimum by maximizing overall system efficiency.
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of the device.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
Please note: The minimum separation distance between the device's antenna and all persons during normal operation is 25 centimeters.
Warning: Any changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. Do not
attempt to tamper or make any changes to this device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux
conditions suivantes :
(1) l’appareil ne doit pas produire de brouillage, et
(2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
Avertissement RF conformité de l’exposition. L’antenne (s) utilisée pour cet émetteur doit être installée pour fournir une distance de séparation d’au moins
25 cm de toutes personnes et ne doit pas être situé à proximité ou fonctionner en conjonction avec une autre antenne ou émetteur.
Tout changement ou modification non expressément approuvé par la partie responsable de la conformité risque d’invalider l’autorisation accordée à l’utilisateur
d’utiliser cet appareil. Les utilisateurs et les installateurs doivent recevoir des instructions d’installation de l’antenne et des conditions de fonctionnement du
transmetteur satisfaisant le respect de l’exposition aux RF.
INSTALATION INSTRUCTIONS
The unit may be installed in the existing alarm panel enclosure. It has been designed for space
saving and efficiency. Once the unit is installed in the enclosure simply install the mag mount
antenna on top of existing enclosure and run the coaxial cable into the enclosure. Now you may
connect the coaxial cable to the module’s RF connector.
CONNECTIONS (Primary use)
Connecting the unit is fast and simple. Simply follow these steps in order to power up the unit
and ensure proper data connectivity.
A) Plug the battery connector into the unit (if you are not using the alarm panel’s auxiliary
power terminals);
B) Plug the AC adapter into the units AC terminals (if you are not using the alarm panel’s
auxiliary power terminals);
C) If you are using the alarm panel’s auxiliary power source then proceed to connect the
unit’s AC/DC terminals to the alarm panel’s auxiliary terminals.
D) Connect to the existing alarm panel data port using the supplied RJ31 jumper;
Please note that further connections may be required depending on the type of installation and
features that are sought.
RF CONNECTIVITY TEST
Once the unit is secured and installed you may now preform an RF network connectivity test.
This is a critical step that must be completed in order to ensure that all messages will be relayed
successfully.
A) Hold the "MODE" button down for 3 seconds until the LED indicator (yellow) lights up
twice, then release;
B) The LED indicator constantly blinks throughout the test run;
C) Keep the unit in the selected location during the whole test run: approximately 90
seconds;
D) The test is finished once the LED indicator stops blinking;
E) Single or double solid green LEDs indicate a successful RF connectivity test. If the test
result in a blinking single RED LED then you must repeat the test one more time. If after
a second attempt the result is still negative then please call our customer service and
technical support department.
Characteristics
Secure and
robust
communication
protocol
Advantages
Benefits
 The RF environment is more and
more saturated, hence the need for
robust communication means.
 Data is transmitted using an encoding
system that maintains a very high
degree of data integrity. It is therefore
possible to recover data even in
extreme circumstances.
Product name: C003 Alarm Interface) Technical specifications
General information
Outside dimensions
Height :
25.40 mm (1.00 inches)
Width :
100.00 mm (3.93 inches)
Length :
100.00 mm (3.93 inches)
Material :
FR4 (no enclosure)
Color :
Black
Operational & Environmental
Operating temp. :
-40 +85°C
Environmental protection :
IP6x (non-immersed)
Specifications ( TX / RX )
Receiver
Span (freq.) :
902.000MHz ~ 928.000MHz
Modulation :
SSFH / 2FSK
Sensitivity:
-114 dBm
Transmitter
Span (freq.) :
902.000MHz ~ 928.000MHz
Modulation :
FH / 2FSK
Encoding :
Variable encoding
Output power :
MAX (1 watt- conducted)
Electrical
Supply voltage (lead in) :
12Vdc
Internal voltage:
3.3Vdc
Electrical consumption:
Variable. Peak 0.05%
Certifications
Industry Canada
RSS-247 Issue 1
FCC (United-States)
Part 15 (C)

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 3
Language                        : en-CA
Tagged PDF                      : Yes
Title                           : CONFIDENTIAL AND PROPRIETARY
Author                          : JMG
Creator                         : Microsoft® Word 2010
Create Date                     : 2016:03:28 16:13:26-04:00
Modify Date                     : 2016:03:28 16:13:26-04:00
Producer                        : Microsoft® Word 2010
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ADQFC003

Navigation menu