Outback Power Systems Fx2012Mt Users Manual OB_Brochure_rev3 11

FX2012MT to the manual f611af39-5b28-6dc4-a9fc-f2d462a535e4

2015-02-05

: Outback-Power-Systems Outback-Power-Systems-Fx2012Mt-Users-Manual-498101 outback-power-systems-fx2012mt-users-manual-498101 outback-power-systems pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadOutback-Power-Systems Outback-Power-Systems-Fx2012Mt-Users-Manual- OB_Brochure_rev3-11  Outback-power-systems-fx2012mt-users-manual
Open PDF In BrowserView PDF
Postage

Mobile
Sinewave Inverter/Chargers

FX2012MT
Sealed Version
Extremely Rugged
Design
(Shown with Turbo option)

Made in USA

Ventilated Version
Bug Proof
Construction

Made in USA
ETL Listed to UL458 Specifications
The Mobile Standard
Also Available in 24 Volt and Export (50 Hz) versions

www.outbackpower.com

RV Electrical System

VFX2812M

ULTRA CLEAN AC POWER

RV-Inverter/Chargers - 120VA 60Hz

Smooth, true sinewave AC output waveform -not an old fashioned modified
Sinewave/Squarewave.
EXTREMELY RUGGED
Built to survive dust, bugs, even rain and salt air. Choice of sealed FX
or bug-proof VFX versions. Installation of the inverter in an RV is now
less of a problem.
EXTREMELY EFFICIENT
Get more power out of your batteries - run larger AC loads longer.
INTELLIGENT BATTERY CHARGER
Advanced charging algorithms provide fast recharging while increasing
battery life. Powerful: up to 125 amps.
VERY QUIET
The sealed FX inverters are virtually silent. The bugproof VFX inverters
only have a variable speed thermostatically controlled fan. No more
transformer buzz to annoy you.

INVERTER SERIES

EASY SYSTEM EXPANSION

Sinewave output waveform

X

X

Systems can grow with your needs - Stack inverters in parallel for more

Modular Building Block Design

X

X

SERVICEABLE

Sealed Construction

X

Both FX and VFX inverter/chargers can be upgraded or serviced - even in

Ventilated Construction

power, or in series for 120/240.

the field.

FX

VFX

Disassembled FX Series

Ruggedized / Tropicalized

X

Ground switching can be defeated for non-mobile applications or for

Rain-proof / Splash-proof

X

CAPABLE TECH SUPPORT HELP

Bug-proof Construction

X

X

You can call or email and ask questions of the engineers that

Die-Cast Aluminum Chassis

X

X

than that.

High Temperature Tolerant

X

X

COOLNESS FACTOR

Built-in Battery Charging System

X

X

Built-in 30amp AC transfer Switch

X

X

Automatic Charger Back-Off

X

X

Compact Size

X

X

Progammable AUX output

X

X

Two wire gen start

X

X

Cooling fan power

X

X

designed your products - Tech support doesn’t get any better

These inverters have a built in “WOW” factor to impress the neighbors
and in-laws.

FEA
T U R E S AV A I L A B L E T H R
OUGH THE MA
TE
AT
ROUGH
MAT
· AC/DC Voltage/Current meters
· On/Off Control of Inverter and Charger
· Selection of AC Cord Amperage

FX2012MT FX2024M VFX2812M VFX3524M
2000W
12

2000W
2800W
24
12
120VAC / 60Hz

17 amps

19-21W
>90%
56amps
40amps
4000W
2500W

10-16V
OBDC-250

100
63 Lbs

17 amps

3500W
24

23.3 amps

29.2amps

18-20W 19-21W
18-20W
92%
>90%
>90%
2% / 5%
±2% TYP
70 amps 56 amps 70 amps
50 amps 40 amps 50 amps
4800W
4000W
5000W
3200W
3200W
4000W
30 amps AC
30 amps AC
80-150VAC
50-70 Hz
20-33V
10-16V
20-33V
OBDC-175

55
60 Lbs

OBDC-250

OBDC-250

125

85
62 Lbs

Assembled FX Series

X

DEFEATABLE NEUTRAL TO GND SWITCHING
multiple Inverter installations.

Inverter/Chargers Model No.
Continuous Power Rating 25° C
Nominal DC Input Voltage
Nominal AC Input Voltage/Frequency
Continuous AC RMS Output Current
Idle Power (Sleep-<3watts)
Efficiency at 75% power & 25° C
Total Harmonic Distortion (typ/max)
Output Voltage Regulation
Surge Power Peak (1mSec) AC
Surge Power RMS (100mSec) AC
Overload (from 25° C start) 5 sec
Overload (from 25° C start) 30min
Automatic AC transfer Relay
AC Input Current (adjustable limits)
AC Input Voltage Range
Frequency Range - AC Input
DC Input Range
Recommended DC Breaker
Continuous Battery Charger amps DC
Shipping Weight

X

WAVEFORMS
Typical “Brand X”
RV Modified Sinewave
Inverter Waveform
Up to 40% Distortion

· Start/Stop Generator Control
· Errors and Warnings Displays
· Programming of Inverter and Charger Operation
· Real time clock with battery backup
· Backlit 4 line display with 80 characters
· Simple plug in wire connection
·

PC Computer Serial Connection Port
(Software Optional)

Typical OutBack
FX or VFX series
AC output waveform
2% Distortion



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Modify, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res
Modify Date                     : 2003:09:26 14:15:20-06:00
Create Date                     : 2003:09:26 14:15:07-07:00
Author                          : Kit
Subject                         : OB_Brochure_rev3-11
Page Count                      : 2
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:a32ab526-541f-4cc0-847d-1133ef75cc74
Producer                        : Acrobat Distiller 6.0 (Windows)
Keywords                        : 
Creator Tool                    : Adobe PageMaker 7.0
Document ID                     : uuid:699aac14-ce84-4602-a51a-d94a329ea4bf
Format                          : application/pdf
Creator                         : Kit
Description                     : OB_Brochure_rev3-11
Title                           : OB_Brochure_rev3-11
EXIF Metadata provided by EXIF.tools

Navigation menu