P AC In t e r n a t i o n a l Lt d .
Low Profile DualTech Reader
Installation Instructions
Part Numbers 20467 (Black) and 20473 (White)
Introduction
The PAC Low Profile DualTech Reader is a proximity reader. This means that no physical contact
is required between the ID device and the reader for the ID device to be read. It usually works with
a door controller to control access through a door. In this case, to open a door, an ID device is
presented to the reader, the reader passes the code to the door controller, and the door controller
validates the code and unlocks the door.
DualTech
PAC produces two categories of ID device, PAC and KeyPAC series format, these are based on
different reading technologies. Readers are available which read either just PAC Format format or
just KeyPAC Format format, however, the PAC DualTech reader is capable of reading both.
Compatible ID Devices
This reader can read PAC and KeyPAC Format ID-devices.
Document No. nnnnnnn
17413 v1.0
(c) PAC 2000. Confidential
This manual is correct at the time of going to press. However, as part of our ongoing product enhancement program we
reserve the right to make changes to the product and/or literature at any time without prior notice to the customer.
Unpacking
Check that all the parts are supplied with your reader. If anything is missing or damaged, contact
your suppliers immediately. The readers are each supplied with the following:
2 x 1” no.6 self tapping screws
Label
Ten cable crimps
MOV
Mounting backplate
Installation
Locating the Reader
Be aware of the following when you choose the location of your reader:
• The cable distance from controller to reader should never exceed 3000ft (1000m) (PAC
equipment only with the appropriate cable, see later). Consult the specification of the chosen
lock to ensure that the maximum distance from controller to lock is acceptable.
• If you use a Request To Exit (RTE) switch, route the wiring so that it is not accessible if the
reader is removed.
• Ensure that the LED is visible to the keyholder, avoid mounting the reader in direct sunlight.
• The best place for a reader is next to the door on the unhinged side at roughly the same
height as the door handle.
• Readers may be located inside or outside, no special protection is needed for readers
mounted outside although corrosion resistant fixings should be used.
• Leave enough room behind the reader for the flying lead.
• Readers can be mounted behind a non-metallic material, such as glass, plastic or wood
without affecting their reading range.
• There should be a minimum 1-metre distance between readers (this includes in and out
readers on opposite sides of a door).
Cable Lengths and Wire Gauges (PAC Equipment Only)
When locating the reader you also need to consider the maximum cable distance to the control
equipment. The following table provides a summary for PAC door controllers only.
Cable Gauge
Distance (reader to PAC door controller)
7/0.2
0.22 mm²
24 AWG
Up to 750 feet (250 metres)
16/0.2
0.5 mm²
20 AWG
Up to 1500 feet (500 metres)
32/0.2
1.0 mm²
18 AWG
Up to 3000 feet (1000 metres)
If you use 24AWG (0.22mm²) cable, you should twist the wires and double them over before
inserting them in the crimps.
Fixing the Reader
3.28”
0.64”
0.32”
1.28”
0.16”
0.4”
0.16”
1.4”
3.8”
0.16”
0.4”
0.4”
0.32”
1.4”
1.08”
1.08”
0.4”
1.28”
0.16”
0.72”
Reader
Mounting Plate
This reader comes in two parts, the reader itself and the backplate. The backplate has a rubber
spacer at the rear.
Fixing the Reader
1. The cable from the controller should be routed through the aperture in the backplate.
Leave enough cable exposed to allow easy wiring of the reader.
Note: There is limited room between the reader and backplate. You should ensure there is
a void large enough behind the backplate to accommodate any excess on the cable.
2. Fix the backplate to a flat surface using the No.6 screws provided - or a fixing suitable for
the material to which the reader is being mounted. The two holes are 2.4 inches (60mm)
apart. Use the top (round) hole first, and the lower (oval) hole to ensure the reader is
straight.
3. Ensure that the reader cable is not connected to the controller. Wire the reader to the
cable as described in this datasheet and in the door controller Installation Manual
4. Push the reader, with the LED to the top, onto the backplate, the fixing tabs on
each side should snap into place.
5. Place label on front of reader.
Removing the Reader
The reader can be removed by placing a small flat-bladed screwdriver into the apertures at the
edges of the snap-fit cover. Take care not to damage the reader or cover.
General Tips
•
The cable distance from controller to reader should never exceed 3000ft (1000m).
•
If using a Request to Exit switch, ensure that the wiring is not accessible if the reader is
removed.
•
Ensure that the LED is always visible to the keyholder.
•
Do not mount in close proximity to metals.
Wiring
All connections are made to the flying lead using the 10 cable crimps provided. Cable gauge
depends on distance from the Door Controller to Reader. The flying lead is 3 ft (1m) long and has
a gauge 24AWG (0.22mm ).
With 24AWG (0.22mm ) cable twist the wires and double them over before inserting them in the
crimps. This includes the flying lead.
Flying
Lead
PAC
Black
GND
White
SIG
Green
Not Used
Brown
VCA/LED
Yellow
Red
SOUNDER – GND to activate
12V DC (+10.5 to +20V)
Blue
TAMPER
Typical PAC Door Controller Wiring
PAC Door Controllers to PAC DualTech Readers can be wired as follows:
Caution: Always consult your door-controller instructions before wiring a reader.
Door
Controller
-V or GND
SIG
DC or DR1
RTE or DR2
Sounder Sw itch
N/O
Door Contact
Blue
Black
N/C
White
SOUNDER
TAMPER
0V
SIG
Request to Exit
N/O
Brown
LED
+V
Note:
Reader
Yellow
Red
Always refer to your controller manual before connection.
VCA/LED
+12V
MOV - Lock Suppression
A metal-oxide-varistor (MOV) is provided with each reader although it is used to protect the door
controller. It prevents high voltage spikes (back e.m.f.s) being returned from the lock unit to the
door controller. High voltage spikes can cause erratic operation and eventually severe damage to
the door controller if not controlled.
CAUTION: Failure to install the MOV at the lock will result in early failure of the door controller. It
will also invalidate the warranty.
The MOV (A) should be installed across the power terminals of the lock (B).
Reader Operation
Normal Operation
The reader LED will normally be red when the door is locked. When a key is presented within
range of the reader, and the key is valid for that door at that time, the LED will go green and the
lock will release. The LED will stay green while the lock is released.
Tamper Protection
To ensure complete tamper protection the DR1 or DC terminal of the door controller should be
connected to the blue lead of the reader. If a door contact is being used then this should be
connected in series with DR1/DC and the blue lead. See the door controller installation manual for
full details of how to set up tamper protection and alarm monitoring.
Sounder Operation
Note: ID devices will not be read while the sounder is operating.
The internal sounder will operate when the yellow lead is grounded. The sounder will continue until
the connection to ground is broken. A relay, such as provided on the 2100 and 2200 Series door
controllers, may be used to provide this operation under various conditions, e.g. Door Left Open.
Specification
Other important features include:
• Integral red/green LED
• Tamper protection
• Integral sounder
Dimensions
See installation diagram.
Approximate Reading Range
KeyPAC Format:
up to 3.2 inches (80mm)
PAC Format:
up to 1.6 inches (40mm)
Note:
These ranges will reduce if the readers are exposed to local sources of electrical
noise.
Power Requirements
Voltage 12V DC (nominal), tolerance +10.5 to +20V. Current < 85 mA
Environmental
Temperature:
Humidity:
Ingress
Protection:
Operating
Storage
Operating
-20ºC (-4F) to +55ºC (131F)
-30ºC (-22F) to +80ºC (176F)
0-90% RH at 30 ± 2ºC (1.8F) for 24 hours
Sealed to IP 66
This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCC ID OQL-PAC-D-LP

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Create Date                     : 2000:12:14 07:52:05
Producer                        : Acrobat Distiller 4.0 for Windows
Modify Date                     : 2000:12:14 07:52:06-05:00
Page Count                      : 6
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OQL-PAC-D-LP

Navigation menu