PBE Europe as Axell Wireless 50-1285SERIES UHF Channelised Repeater type 50-128501 User Manual

Axell Wireless UHF Channelised Repeater type 50-128501

User manual

Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-1 of 39         Two Channel 400MHz Cell Enhancer User Handbook For AFL Inc. AFL Works Order N.:   Q112941 AFL product part N.:  50-128501
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-2 of 39   Table of Contents  AMENDMENT LIST RECORD SHEET ...................................................................................................4 INTRODUCTION.........................................................................................................................................5 Scope ........................................................................................................................................................................... 5 Purpose ....................................................................................................................................................................... 5 Glossary of Terms...................................................................................................................................................... 6 Key to AFL RF Module Drawing Symbols ............................................................................................................. 7 1. SAFETY CONSIDERATIONS.........................................................................................................8 1.1 Earthing of Equipment ................................................................................................................................ 8 1.2 Electric Shock Hazard.................................................................................................................................. 8 1.3 RF Radiation Hazard ................................................................................................................................... 9 1.4 Chemical Hazard ........................................................................................................................................ 10 1.5 Emergency Contact Numbers.................................................................................................................... 10 2. OVERVIEW/SYSTEM DESCRIPTION .......................................................................................11 3. SPECIFICATIONS..........................................................................................................................12 3.1 Description .................................................................................................................................................. 12 3.2 Electrical Specification............................................................................................................................... 12 3.3 Mechanical Specification............................................................................................................................ 13 3.4 System Diagram.......................................................................................................................................... 14 3.5 Parts Lists.................................................................................................................................................... 15 4. SUB-UNIT MODULES....................................................................................................................17 4.1 UHF Notch Filter (02-020001) ................................................................................................................... 17 4.1.1 Description ............................................................................................................................................... 17 4.1.2 Technical Specifications ........................................................................................................................... 17 4.2 Bandpass Filters (02-011204 & 02-013401) .............................................................................................. 18 4.2.1 Description ............................................................................................................................................... 18 4.2.2 Technical Specification............................................................................................................................. 18 4.3 30dB Power Monitor (07-012501) ............................................................................................................. 19 4.3.1 Description ............................................................................................................................................... 19 4.3.2 Technical Specification............................................................................................................................. 19 4.4 ¼Watt 0- -30dB Switched Attenuator (10-000701)..................................................................................19 4.4.1 General Application ................................................................................................................................. 19 4.4.2 Switched Attenuators ................................................................................................................................ 19 4.5 Low Noise Amplifier (11-007402).............................................................................................................. 20 4.5.1 Description ............................................................................................................................................... 20 4.5.2 Technical Specification............................................................................................................................. 20 4.5.3 LNA ‘D’ Connector Pin-out details.......................................................................................................... 20 4.6 1Watt Low Power Amplifier (11-007901)................................................................................................. 21 4.6.1 Description ............................................................................................................................................... 21 4.6.2 Technical Specifications ........................................................................................................................... 21 4.7 5Watt Medium Power Tetra Amplifier (12-021601) ............................................................................... 22 4.7.1 Description ............................................................................................................................................... 22 4.7.2 Technical Specification............................................................................................................................. 22 4.7.3 PA 7-Way Connector Pin-outs.................................................................................................................. 22 4.7.4 PA Connector (7) Pin-Outs ...................................................................................................................... 23 4.8 Single DC/DC Converters (13-001704 & 13-001710) .............................................................................. 24 4.8.1 Description ............................................................................................................................................... 24 4.8.2 Technical Specification............................................................................................................................. 24 4.9 Controller/Monitor Board (17-005803) .................................................................................................... 25 4.9.1 Description ............................................................................................................................................... 25 4.9.2 Drg. Nō. 17-005880, Controller/Monitor PCB Pin-Outs......................................................................... 26 4.10 Channel Selective Modules (17-009304 & 17-009305)............................................................................. 27
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-3 of 39  4.10.1 Description ........................................................................................................................................... 27 4.10.2 Drg. Nō. 17-003080, Generic Channel Module Block Diagram.......................................................... 28 4.11 12V Single Relay Board (80-008901) ........................................................................................................ 29 4.11.1 Description ........................................................................................................................................... 29 4.12 PP9 NiCad Backup Battery (96-000017) ................................................................................................. 29 4.13 15V Switch-Mode PSU (96-300054) .......................................................................................................... 30 4.13.1 Description ........................................................................................................................................... 30 4.13.2 Technical Specification......................................................................................................................... 30 4.14 MT2834ZDXK 56kBPS Modem (96-800003)........................................................................................... 30 4.14.1 Description ........................................................................................................................................... 30 5. INSTALLATION .............................................................................................................................31 5.1 Initial Installation Record.......................................................................................................................... 31 5.2 Antenna Installation & Gain Calculations ............................................................................................... 31 5.3 Antenna Isolation........................................................................................................................................ 32 5.4 General Remarks........................................................................................................................................ 33 5.5 Electrical Connections................................................................................................................................ 33 5.6 RF Connections........................................................................................................................................... 33 5.7 RS232 Setup ................................................................................................................................................ 33 6. MAINTENANCE .............................................................................................................................34 6.1 General Procedures .................................................................................................................................... 34 6.1.1 Quick Fault Checklist ............................................................................................................................... 34 6.1.2 Fault Finding............................................................................................................................................ 34 6.1.3 Downlink................................................................................................................................................... 35 6.1.4 Uplink ....................................................................................................................................................... 35 6.1.5 Fault repair............................................................................................................................................... 35 6.1.6 Checking service....................................................................................................................................... 36 6.1.7 Service Support......................................................................................................................................... 36 6.2 Tools & Test Equipment ............................................................................................................................ 36 6.3 Care of Modules.......................................................................................................................................... 37 6.3.1 General Comments ................................................................................................................................... 37 6.3.2 Module Removal (LNA’s, general procedure): ........................................................................................ 37 6.3.3 Module Replacement (general): ............................................................................................................... 37 6.3.4 Power Amplifiers ...................................................................................................................................... 37 6.3.5 Low Power Amplifier Replacement .......................................................................................................... 38 6.3.6 Module Transportation: ........................................................................................................................... 38 APPENDIX A INITIAL EQUIPMENT SET-UP CALCULATIONS.................................................39
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-4 of 39  AMENDMENT LIST RECORD SHEET  Issue Nō. Date  Incorporated by Page No.’s Amended Reason for new issue A 10/11/04  CMH    1st Draft 1   CMH    1st Issue                                                                                                                                         Document Ref:-50-113901HBK
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-5 of 39   INTRODUCTION  Scope  This handbook is for use solely with the equipment identified by the AFL Part Number shown on the front cover. It is not to be used with any other equipment unless specifically authorised by Aerial Facilities Limited.  Purpose  The purpose of this handbook is to provide the user/maintainer with sufficient information to service and repair the equipment to the level agreed. Maintenance and adjustments to any deeper level must be performed by AFL, normally at the company’s repair facility in Chesham, England.  This handbook has been prepared in accordance with BS 4884, and AFL’s Quality procedures, which maintain the company’s registration to BS EN ISO 9001:2000 and to the R&TTE Directive of the European Parliament. Copies of the relevant certificates and the company Quality Manual can be supplied on application to the Quality Manager. This document fulfils the relevant requirements of Article 6 of the R&TTE Directive.  Limitation of Information Notice  This manual is written for the use of technically competent operators/service persons. No liability is accepted by AFL for use or misuse of this manual, the information contained therein, or the consequences of any actions resulting from the use of the said information, including, but not limited to, descriptive, procedural, typographical, arithmetical, or listing errors.  Furthermore, AFL does not warrant the absolute accuracy of the information contained within this manual, or it’s completeness, fitness for purpose, or scope.  AFL has a policy of continuous product development and enhancement, and as such, reserves the right to amend, alter, update and generally change the contents, appearance and pertinence of this document without notice.  All AFL products carry a twelve month warranty from date of shipment. The warranty is expressly on a return to base repair or exchange basis and the warranty cover does not extend to on-site repair or complete unit exchange.
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-6 of 39   Glossary of Terms  Repeater or Cell Enhancer  A Radio Frequency (RF) amplifier which can simultaneously amplify and re-broadcast Mobile Station (MS) and Base Transceiver Station (BTS) signals.  Band Selective Repeater  A Cell Enhancer designed for operation on a range of channels within a specified frequency band.  Channel Selective Repeater  A Cell Enhancer, designed for operation on specified channel(s) within a specified frequency band. Channel frequencies may be factory set or on-site programmable.  BTS    Base Transceiver Station C/NR    Carrier-to-Noise Ratio Downlink (D.L.)    RF signals transmitted from the BTS and to the MS Uplink (U.L.)     RF signals transmitted from the MS to the BTS EMC    Electromagnetic Compatibility GND    Ground DC    Direct Current AC    Alternating Current ID    Identification Number OIP3    Output Third Order Intercept Point = RFout +(C/I)/2 LED    Light Emitting Diode M.S.    Mobile Station N/A    Not Applicable N/C    No Connection NF    Noise Figure RF    Radio Frequency Rx    Receiver Tx    Transmitter S/N    Serial Number
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-7 of 39  Key to AFL RF Module Drawing Symbols
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-8 of 39   1. SAFETY CONSIDERATIONS  1.1 Earthing of Equipment  Cell Enhancers supplied from the mains must be connected to grounded outlets and earthed in conformity with appropriate local, national and international electricity supply and safety regulations.  1.2 Electric Shock Hazard  Electrical shocks due to faulty mains driven power supplies. Whilst ever potentially present in any electrical equipment, such a condition would be minimised by quality installation practice and thorough testing at:  a) Original assembly  b) Commissioning  c)  Regular intervals, thereafter.  All test equipment to be in good working order prior to its use. High current power supplies can be dangerous because of the possibility of substantial arcing. Always switch off during disconnection and reconnection.
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-9 of 39   1.3 RF Radiation Hazard     RF radiation, (especially at UHF frequencies) arising from transmitter outputs connected to AFL’s equipment, must be considered a safety hazard.  This condition might only occur in the event of cable disconnection, or because a ‘spare’ output has been left unterminated. Either of these conditions would impair the system’s efficiency. No investigation should be carried out until all RF power sources have been removed. This would always be a wise precaution, despite the severe mismatch between the impedance of an N type connector at 50, and that of free space at 377, which would severely mitigate against the efficient radiation of RF power. Radio frequency burns could also be a hazard, if any RF power carrying components were to be carelessly touched!  Antenna positions should be chosen to comply with requirements (both local & statutory) regarding exposure of personnel to RF radiation. When connected to an antenna, the unit is capable of producing RF field strengths, which may exceed guideline safe values especially if used with antennas having appreciable gain. In this regard the use of directional antennas with backscreens and a strict site rule that personnel must remain behind the screen while the RF power is on, is strongly recommended.  Where the equipment is used near power lines, or in association with temporary masts not having lightning protection, the use of a safety earth connected to the case-earthing bolt is strongly advised.
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-10 of 39   1.4 Chemical Hazard   Beryllium Oxide, also known as Beryllium Monoxide, or Thermalox™, is sometimes used in devices within equipment produced by Aerial Facilities Ltd. Beryllium oxide dust can be toxic if inhaled, leading to chronic respiratory problems. It is harmless if ingested or by contact.  Products that contain beryllium are load terminations (dummy loads) and some power amplifiers. These products can be identified by a yellow and black “skull and crossbones” danger symbol (shown above). They are marked as hazardous in line with international regulations, but pose no threat under normal circumstances. Only if a component containing beryllium oxide has suffered catastrophic failure, or exploded, will there be any danger of the formation of dust. Any dust that has been created will be contained within the equipment module as long as the module remains sealed. For this reason, any module carrying the yellow and black danger sign should not be opened. If the equipment is suspected of failure, or is at the end of its life-cycle, it must be returned to Aerial Facilities Ltd for disposal.  To return such equipment, please contact the Quality Department, who will give you a Returned Materials Authorisation (RMA) number. Please quote this number on the packing documents, and on all correspondence relating to the shipment.  PolyTetraFluoroEthylene, (P.T.F.E.) and P.T.F.E. Composite Materials Many modules/components in AFL equipment contain P.T.F.E. as part of the RF insulation barrier. This material should never be heated to the point where smoke or fumes are evolved. Any person feeling drowsy after coming into contact with P.T.F.E. especially dust or fumes should seek medical attention.  1.5 Emergency Contact Numbers  The AFL Quality Department can be contacted on:  Telephone   +44 (0)1494 777000 Fax    +44 (0)1494 777002 e-mail   qa@aerial.co.uk
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-11 of 39   2. OVERVIEW/SYSTEM DESCRIPTION  This equipment is designed to enhance one 275kHz spaced channel in the 400MHz UHF band, and one IF select channel having 1.45MHz bandwidth also in the 400MHz band using 5 and 1Watt amplifiers on the downlink and uplink paths respectively.  An RS232 controller/monitor together with a modem is fitted to provide remote monitoring of all active alarms and to allow remote re-configuration of channel module frequencies. See the RS232 controller/monitor handbook (17-005801HBKM) for more details on this feature.
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-12 of 39   3. SPECIFICATIONS  3.1 Description    See section 2.      3.2 Electrical Specification  PARAMETER  SPECIFICATION (Area) downlink: 489.5125-490.9625MHz (Police) downlink: 496.3375-496.6125MHz (Area) uplink: 492.5125-493.9625MHz Frequency bands (Police) uplink: 499.3375-499.6125MHz N. of Channels: 2 (one IF select 1.45MHz b/w) Downlink1 bandwidth: 1.45MHz Downlink2 bandwidth: 275kHz Passband Ripple: ±1.5dB Gain: >90dB Gain Adjustment: 30dB in 2 dB steps Uplink ALC setting: +28dBm Downlink ALC setting: +35dBm Downlink: 28dBm O/P Power/Channel @ Ant. Port Uplink: 24dBm O/P 1dB compression @ antenna port: 37.5dBm Uplink noise: >5dB operation: -10°C to +55°C Temperature range  storage: -40°C to +70°C VSWR: Better than 1.5:1 Impedance: 50 Power Supply Requirement: 110V AC single phase Alarms fitted (RS232): Amplifiers, PSU, Door, Temperature
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-13 of 39   3.3 Mechanical Specification    PARAMETER  SPECIFICATION Height:  620mm Width:  620mm Case size Depth:  250mm (excluding heatsinks, connectors, handles and feet) Fixings:  4 holes on 670(w) x 558(h)mm operational: -10°C to +60°C Temperature range: storage:  -40°C to +70°C Weight: >30kg (approximately) RF Connectors: N type female Environmental Protection: IP65 (with door closed and all ports terminated) Case:  To RAL 7035 Heatsinks:  Matt black (where fitted) Finish: Handles:  Black technopolymer Supply Cable:  Unit supplied with suitable supply input leads with connector and appropriate length of cable
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-14 of 39  3.4 System Diagram 37dB 30dBBASE MOBILE30dB11-00790111-00740230dB12-02160130dB   11-00740230dB11-0074020dB0dB   11-00740230dB11-00740230dB30dB0dB   11-00740237dB 30dB11-00790130dB   11-00740211-0074020dB489.5125-490.9625496.3375-496.6125492.5125-493.9625499.3375-499.612517-00930417-00930417-00930517-009305Q112941 50-128501dBdB10-00070110-000701dBdB10-00070110-00070102-02000130dB30dB
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-15 of 39   3.5 Parts Lists  AFL Part Nō.  Part Description  Qty. 02-020001  UHF 2 SECTION NOTCH FILTER SMA  2 02-011204  6P TETRA C/L FILT(1.5-4MHz) SMA  4 02-013401  6P CL FLTR(0.5 min BW)LARGE SMA ASSY  4 07-012501  POWER MONITOR UHF DUAL  2 10-000701  0.25W 0-30dB SWITCHED ATTENUATOR  4 11-007402  LNA. 380-500MHz 30dB (C/W RELAY) GA  8 11-007901  AMPLIFIER TETRA 1W 37dB GAIN ASS  2 12-021601  TETRA 5W +12V AMPLIFIER  2 13-001704  VOLTAGE REGULATOR BOARD 9.0V  1 13-001710  VOLTAGE REGULATOR BOARD 5.0V  1 13-003301  MAINS FILTER 8AMP ASSEMBLY  1 17-000126  CELL ENHANCER LABEL 6 DIGIT  1 17-000526  CE 10/20W HEATSINK THERMAL GASKET  3 17-002020  PLEASE USE KIT 17-002020K  1 17-002103  26WAY RIBBON CABLE LEAD  4 17-003022  MODULE PATTERNED LEAVE  4 17-003023  SUBRACK SIDE PANEL  2 17-003024  SUBRACK REAR BRACKET  4 17-003025  BOTTOM MODULE GUIDE  4 17-003028  MODULE SQUARE LEAVE  4 17-003029  TOP MODULE GUIDE  4 17-005803  CONTROLLER MONITOR BOARD 12V  1 17-005820 MONITOR/CONTROLLER COVER  1 17-005821  MON/CONTROLLER ACCESS PLT LRG  1 17-005822  MON/CONTROLLER ACCESS PLT SML  1 17-009304  UHF CHAN MOD 480-500MHz, 400kHz B/W  2 17-009305  UHF CHAN MOD 480-500MHz, 2 MHz B/W  2 80-008901  12V RELAY PCB ASSEMBLY  1 80-032320  10W PA HEATSINK  2 80-310420  BCC 400W POWER SUPPLY HEATSINK  1 90-100003  MAINS LEAD '6 AMP'  1 90-400006 ALARM LEADS  1 91-030002  N ADAPTOR PANEL FEMALE:FEMALE  4 91-130001  SMA ADAPT 'T' ALL FEMALE 3 GHz  6 91-500011  PWR 3POLE PNL PLUG SEALED IP68  1 91-500015  PWR CON CAP SEALED with INT. THREAD  2 91-500016  PWR 6POLE PNL PLUG SEALED IP68  1 91-600001  'D'TYPE 9 WAY PLUG S/B TERM  1 91-600014  'D' 9 WAY SOCKET S/B (NON FILTERED)  8 91-640004  LARGE PIN FOR 91-660001 D SOCKET  4 91-660001  2W5 MIXED D TYPE SOCKET (7 WAY)  2 91-700015  ICD 10 WAY IDC CONNECTOR  1
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-16 of 39  91-700017  ICD 15 WAY 0.1' CONNECTOR  3 92-120009  M20 IP68 CABLE GLAND  1 92-280033 Captive Screw  20 92-280044  SCREW SLOTTED COLLAR  20 92-400017  GASKET FOR N TYPE CONNECTOR  2 93-510041  27R 1.6W % RESISTOR H:P PR37  1 94-120003  1645 SCH0TTKY DIODE 16A MBR  1 96-000017  PP9 NiCad BATTERY  1 96-000018  CONNECTOR FOR PP9 BATTERY  1 96-300057  15V 27A PSU 400W (XP BCC)  1 96-700034  LED RED 5mm IP67  1 96-700035  LED GREEN 5mm IP67  1 96-800003  MT2834ZDXK 56kBPS MODEM WORLD  1 96-900018  AC TRIP SWITCH (5 AMP M.C.B.)  1 96-920011 PROXIMITY SWITCH  1 96-920012  PROXIMITY SWITCH MAGNET  1 97-000001  'SAREL' S/S HEAVY DUTY WALL BKT (4)  1 97-000002  BLACK MODULE CAGE RUNNER  20 97-300010  C/E SUPPLY INPUT COVER  2 97-400010  BLACK PLASTIC HANDLE 50mm HIGH  2 97-600001  SUBRACK FRONT HORIZ  4 97-600002  SUBRACK M2.5 STD TAP  4 97-900004  RUBBER FOOT FOR CELL ENHANCERS  4 99-200017  CAUTION HEAVY LABEL 75 x 55mm  1  *  Highlighted items appear in ‘Sub-Unit Modules’ section.
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-17 of 39   4. SUB-UNIT MODULES  4.1 UHF Notch Filter (02-020001)  4.1.1 Description  The notch reject filters fitted here are tuned to eliminate the unwanted channel frequencies of the band 1 amplifier (where the filters are fitted in the band 2 path and vice-versa). The filters should require no routine maintenance, being totally passive devices. If a filter is suspected of failure, no invasive measures are recommended as even opening the case of the device could render it unusable.  4.1.2 Technical Specifications  PARAMETER  SPECIFICATION Passband1  492.5-494 & 490.6MHz Passband2  481-489 & 496.3-496.6MHz Stopband1:  496.3 & 496.5MHz Stopband2:  492.5-494, 496.3-496.6 & 494-494.5MHz Insertion Loss:  0.6dB typical Rejection: 40dB typical Power Rating  50 Watt Impedance 50 VSWR  Better than 1.22:1
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-18 of 39   4.2 Bandpass Filters (02-011204 & 02-013401)  4.2.1 Description  The bandpass filters are multi-section designs with a bandwidth dependent upon the passband frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with a passband design ripple of 0.1dB. The filters are of combline design, and are carefully aligned during manufacture in order to optimise the insertion loss, VSWR and intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface ohmic losses and maintain a good VSWR figure and 50 load at the input and output ports.  Being passive devices, the bandpass filters should have an extremely long operational life and require no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module rather than attempt repair or re-tuning.    4.2.2 Technical Specification  FILTER 1 489.5-491 MHz  (02-011204) FILTER 2 496.3-496.7 MHz  (02-013401) FILTER 3 492.5-494 MHz  (02-011204) Passband: FILTER 3 499.3-499.7 MHz  (02-013401) FILTER 1 3.0 dB   (02-011204) FILTER 2 3.5 dB   (02-013401) FILTER 3 3.0 dB   (02-011204) Insertion Loss: FILTER 3 3.5 dB   (02-013401) FILTER 1 MAX(>40dB)  (02-011204) FILTER 2 MAX (>40dB)  (02-013401) FILTER 3 MAX (>40dB)  (02-011204) Isolation: FILTER 4 MAX (>40dB)  (02-013401) Impedance: 50 ohm
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-19 of 39   4.3 30dB Power Monitor (07-012501)  4.3.1 Description  The purpose of these couplers is to tap off known portions (usually 15-30dB) of RF signal from transmission lines at the antenna ports, either resistively or by induction, and to combine them, for example through splitter units for different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all ports/interfaces throughout the specified frequency range. They are formally known as directional couplers as they couple power from the RF mainline in one direction only.  Various constructional techniques are used depending on the specification required. These include microstrip, stripline, coaxial cable and capacitive types.  4.3.2 Technical Specification   PARAMETER  SPECIFICATION Frequency range: 350 – 550MHz Insertion Loss: <0.3dB Coupling level: -30dBc Rejection: N/A Weight: <200gms Connectors: N type, female operation:  -10°C to +60°C Temperature range:  storage:  -20°C to +70°C  4.4 ¼Watt 0- -30dB Switched Attenuator (10-000701)  4.4.1 General Application  In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the gain.  4.4.2 Switched Attenuators  The AFL switched attenuators are available in two different types; 0 – 30dB in 2 dB steps (as in this case), or 0 – 15dB in 1 dB steps. The attenuation is simply set using the four miniature toggle switches on the top of each unit. Each switch is clearly marked with the attenuation it provides, and the total attenuation in line is the sum of the values switched in. They are designed to maintain an accurate 50 impedance over their operating frequency at both input and output.
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-20 of 39   4.5 Low Noise Amplifier (11-007402)  4.5.1 Description  The 30dB gain low noise amplifier used is a double stage solid-state low-noise amplifier. Class A circuitry is used in the unit to ensure excellent linearity over a very wide dynamic range. The two active devices are very moderately rated to provide a long trouble-free working life. There are no adjustments on this amplifier, and in the unlikely event of failure then the entire amplifier should be replaced. The amplifier features a dedicated, in-built alarm monitoring system which gives a TTL ‘open collector’ type switched signal on alarm, this is then integrated using a built-in relay to give a volt-free contact for summation into the main alarm system.  4.5.2 Technical Specification  PARAMETER  SPECIFICATION Frequency range: 380-500MHz Bandwidth: <140MHz Gain: 30-32dB 1dB Compression Point: +22dBm (typical) 3rd order intercept: +34-35dBm (typical) Input/Output return loss: >20dB Noise figure: <1.3dB Connectors: SMA female Supply: 300-330mA @ 24V DC operational:  -10°C to +60°C Temperature range:  storage: -20°C to +70°C Weight: 0.38kg Size: 90 x 55 x 30.2 (case only)  4.5.3  LNA ‘D’ Connector Pin-out details  Connector pin  Signal 1  +Ve input (10-24V) 2 GND 3  Alarm Relay O/P bad 4  Alarm Relay common 5  Alarm Relay good 6 No connection 7  TTL voltage set 8  TTL alarm/0V (good) 9  O/C good/0V bad
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-21 of 39   4.6 1Watt Low Power Amplifier (11-007901)  4.6.1 Description  This amplifier is dedicated to be a 1.0 W driver from 380 MHz to 470 MHz. It is a 2 stage amplifier where each stage is in balanced configuration. It demonstrates very high linearity and good input/output VSWR. There is a Current Fault Alarm Function, which indicates failure of each one of the RF transistors by various alarm output options. The amplifier is housed in an aluminium case (Alocrom 1200 finish) with SMA connectors for the RF input/output and a 9way D-type connector for DC and alarm outputs.  4.6.2 Technical Specifications  PARAMETER  SPECIFICATION Frequency range: 380-470MHz Small signal gain: 37.5dB Gain flatness: ±0.5dB Gain vs. temperature: 1.5dB operational: -10°C to +60°C Temperature range:  storage: -20°C to +70°C Input/output return loss: 18dB Maximum output power: 30.4dBm (@ 1dB comp. point) OIP3: 43dBm Supply voltage: 10-15V DC Current consumption: 780mA (typical) Noise Figure: <1.75dB
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-22 of 39   4.7 5Watt Medium Power Tetra Amplifier (12-021601)  4.7.1 Description  The power amplifier fitted to this unit is a multi-stage, solid state power amplifier. Class A circuitry is employed throughout the device to ensure excellent linearity over a wide dynamic frequency range. All the semi-conductor devices are very conservatively rated to ensure low device junction temperatures and a long, trouble free working lifetime.  The power amplifier should require no maintenance over its operating life. Under no circumstances should the cover be removed or the side adjustments disturbed unless it is certain that the amplifier has failed; since it is critically aligned during manufacture and any re-alignment will require extensive test equipment.  4.7.2 Technical Specification  PARAMETER  SPECIFICATION Frequency range: 380-470MHz (as required) Bandwidth: 10-40MHz (typical, tuned to spec.) Maximum RF output: >5Watts Gain: >30dB 1dB compression point: +37.5dBm 3rd order intercept point: +50dBm VSWR: better than 1.5:1 Connectors: SMA female Supply: 1.9Amps @ 12V DC Weight: 1kg (excluding heatsink) operational: -10°C to +60°C Temperature range:  storage: -20°C to +70°C  4.7.3  PA 7-Way Connector Pin-outs  Connector Pin  Signal A1 (large pin)  +12V DC A2 (large pin)  GND 1  Alarm relay common 2  TTL alarm/0V good 3  Alarm relay contact (bad) 4  Alarm relay contact (good) 5  O/C good/0V bad (TTL)
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-23 of 39   4.7.4  PA Connector (7) Pin-Outs
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-24 of 39   4.8 Single DC/DC Converters (13-001704 & 13-001710)  4.8.1 Description  This unit it is used to derive a fixed voltage power supply rail from some higher voltage. Typically, it is used to derive 5V, 8V, 12V or 15V from a 24V input.  The circuit is based upon an LM317 variable voltage regulator, which is capable of supplying a maximum of 1.5A output current. Note that at full output current the dissipation of the device must remain in limits, bearing in mind the voltage which is being dropped across it. The maximum allowable dissipation will also depend on the efficiency of the heatsink on which the device is mounted.  The output voltage of the unit is programmed by the resistive divider which is fitted between the output terminal, the reference terminal and ground. R1 is the reference programming resistor and is fixed in all versions. R2 is fitted on 12V versions while R3, (which is in parallel with R2) is fitted on 8V and 5V versions.  4.8.2 Technical Specification  PARAMETER  SPECIFICATION Operating Voltage: 21 – 27V DC 5.0V (13-001710) Output Voltages: 9.0V (13-001704) Output Current: 1.0A (maximum per o/p) Connections: Screw Terminal Block operational: -10%C to +60%C Temperature range:  storage: -20%C to +70%C PCB Size: 47 x 30mm
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-25 of 39   4.9 Controller/Monitor Board (17-005803)  4.9.1 Description  To meet the need for detailed control and status reporting of cell enhancers and other systems installed in inaccessible locations, AFL has developed an optional RS232C (RS232D) serial interface which may be incorporated into any of AFL’s range of cell enhancers. The RS232 interface is designed primarily to be connected to a modem, which can then communicate either via a fixed or a cellular telephone link with another modem at the network control centre. As standard, the interface will control any modem that works with the Hayes command set, although it can easily be adapted to control other equipment if required.  The controller software has been written so that it is easily configured to meet specific customer interface requirements. The standard software has two data formats. Firstly, a verbose format that can be controlled from a simple terminal or terminal emulator. Secondly, a terse data format intended to be used with front-end software running on another computer to present a very user-friendly operator interface. If required, alternative data formats can be provided to enable integration with existing customer front-end software.  The RS232 interface board within the Cell Enhancer integrates all the alarm inputs from the amplifier alarm boards, as well as from relays monitoring power supply status, door open/closed status, I.F module status, and standby battery voltage status. Monitoring of forward power can also be done. All this information is combined and formatted with on-board generated data including temperature, date, time and equipment serial number.  The RS232 interface board also controls the frequencies at which the channel modules operate. These frequencies can, via a modem, be adjusted remotely. For more details, see the RS232 interface board handbook (17-005801HBKM). The PCB fitted here is a 12V version of the standard 24V board, (denoted by the ‘03’ at the end of the AFL part number) – but all the electronic functions are identical.
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-26 of 39  4.9.2 Drg. N. 17-005880, Controller/Monitor PCB Pin-Outs
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-27 of 39   4.10 Channel Selective Modules (17-009304 & 17-009305)  4.10.1 Description  The channel selectivity module is employed when the Cell Enhancer requirement dictates that very narrow bandwidths (single operating channels), must be selected from within the operating passband. One channel selectivity module is required for each channel.  The Channel Selectivity Module is an Up/Down frequency converter that mixes the incoming channel frequency with a synthesised local oscillator, so that it is down-converted to an Intermediate Frequency (IF) in the upper HF range. An eight pole crystal filter in the IF amplifier provides the required selectivity to define the operating passband of the Cell Enhancer to a single PMR channel. The same local oscillator then converts the selected IF signal back to the channel frequency.  Selectivity is obtained from a fixed bandwidth block filter operating at an intermediate frequency (IF) in the low VHF range. This filter may be internal to the channel selectivity module (Crystal or SAW filter) or an externally mounted bandpass filter, (LC or Helical Resonator). Various IF bandwidths can therefore be accommodated. A synthesized Local Oscillator is employed in conjunction with high performance frequency mixers, to translate between the signal frequency and IF.  The operating frequency of each channel selectivity module is set by the programming of channel selectivity module frequencies and is achieved digitally, via hard wired links, banks of DIP switches, or via an onboard RS232 control module, providing the ability to remotely set channel frequencies.  Automatic Level Control (ALC) is provided within each channel selectivity module such that the output level is held constant for high level input signals. This feature prevents saturation of the output mixer and of the associated amplifiers.  Alarms within the module inhibit the channel if the synthesised frequency is not locked. The synthesiser will not usually go out of lock unless a frequency far out of band is programmed.  The channel selectivity module is extremely complex and, with the exception of channel frequency programming within the design bandwidth, it cannot be adjusted or repaired without extensive laboratory facilities and the necessary specialised personnel. If a fault is suspected with any channel selectivity module it should be tested by substitution and the complete, suspect module should then be returned to AFL for investigation.
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-28 of 39  4.10.2 Drg. N. 17-003080, Generic Channel Module Block Diagram
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-29 of 39   4.11 12V Single Relay Board (80-008901)  4.11.1 Description  The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is equipped with a single dual pole change-over relay RL1, with completely isolated wiring, accessed via a 15 way in-line connector.  The relay is provided with polarity protection diodes and diodes for suppressing the transients caused by "flywheel effect" which can destroy switching transistors or induce spikes on neighbouring circuits. It’s common use is to amalgamate all the alarm signals into one, volts-free relay contact pair for the main alarm system.  Note that the board is available for different voltages (12 or 24V) depending on the type of relay fitted at RL1.  4.12  PP9 NiCad Backup Battery (96-000017)  The NiCad rechargeable battery fitted in this system is trickle-charged from the main 12V supply by a diode and resistor and powers the RS232 controller/monitor board and the telephone line modem in the case of a power failure. This gives the controller and modem sufficient time to dial out and alert the control centre of the new (failure) status of the
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-30 of 39   4.13 15V Switch-Mode PSU (96-300054)  4.13.1 Description  The power supply unit is a switched-mode type capable of supplying 15V DC at 27Amps continuously. The amplifiers in this unit will draw approximately 12-15Amps at 15V DC, so the PSU will be used conservatively ensuring a long operational lifetime.  No routine maintenance of the PSU is required. If a fault is suspected, then the output voltage from the power supply may be measured on its output terminals. This is typically set to 15.2V. The adjustment potentiometer will be found close to the DC output terminals.  All the PSU’s used in AFL Cell Enhancers are capable of operation from either 110 or 220V nominal AC supplies. The line voltage is sensed automatically, so no adjustment or link setting is needed by the operator.  4.13.2 Technical Specification  AC Input Supply: 110 or 220V nominal Voltage:  90 to 132 or 180 to 264V (absolute limits) Frequency:  47 to 63Hz DC Output Supply: 15V DC (nominal) Voltage: 12-17V (absolute limits) Current: 27.0A  4.14 MT2834ZDXK 56kBPS Modem (96-800003)  4.14.1 Description  The modem used is a standard, 56kBPS, O.E.M, ‘Hayes instruction set’ unit. Used in conjunction with the Controller/Monitor board it is the output termination of all the alarm system data which is then transmitted into the regular telephone network by standard dial up. More information on the set-up & use of the modem can be found in the Controller/Monitor Handbook (17-005801HBKM).
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-31 of 39   5. INSTALLATION  5.1 Initial Installation Record  When this equipment is initially commissioned, please use the equipment set-up record sheet in Appendix A. This will help both the installation personnel and AFL should these figures be needed for future reference or diagnosis.  5.2 Antenna Installation & Gain Calculations  1  Most Cell Enhancer require two antennas, one a highly directional Yagi or similar directed towards the donor cell base station, and one a leaky feeder, omni-directional antenna or Yagi to cover the area in which the mobiles are to be served.  2  The maximum gain at which the Cell Enhancer can be set is limited by the isolation that can be achieved between these two antennas. Therefore when the antennas have been installed, inject a signal (at a known power level) into one of them and measure the signal level received by the other antenna on a spectrum analyser. The isolation can then be calculated as the difference between these two figures. The gain in each path of the Cell Enhancer should be set at least 10 dB below this figure, using attenuators as described below in paragraph 5.  3  Also measure the received signal from the donor cell at the input to the Cell Enhancer (base port). The gain of the Cell Enhancer downlink path should be set such the donor site will not overload the Cell Enhancer amplifiers. It is recommended that the input level should be less than -50dBm at the input of the Cell Enhancer (Base Port). (This figure is assuming maximum gain, and may be increased by the value of the attenuator fitted in the downlink path.)  4  Ensure that the mobile facing antenna has at least 70 dB isolation from the nearest mobile. (This is usually easily achieved when using a leaky feeder.)  5  The Cell Enhancer gain is set by setting the attenuation in each path (uplink and downlink) between the first two amplifier stages (see markings within the Cell Enhancer or layout drawings for the exact attenuator locations). Note that the uplink (mobile to base) and downlink (base to mobile) path gains are set independently. This allows the paths to have different gains if required to set the correct output power levels.  6  It is recommended that the gains are set such that the Downlink channel output levels from the Cell Enhancer are typically +30dBm per channel (Input level + Gain = Output level).
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-32 of 39  5.3 Antenna Isolation                                         Base Site Mobiles Yagi or leaky feederYagi Measure Isolation Between antennas B) Install the Cell Enhancer with its gain set 10dB below the isolation figure obtained above. Yagi or leaky feederYagiBase Port Mobile PortCell EnhancerBase Site (donor) MobileA).  First set up the two antennas & measure the isolation between them.
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-33 of 39   5.4 General Remarks  The size and weight of the wall-mount case is such that 2/3 persons may be needed to lift the equipment into position. Test the mechanical installation in the interests of safety, before any electrical, RF, or optical connections are made.  The equipment must be located on a smooth, flat, perpendicular surface, sheltered if possible, that is made from a material suitable for bearing the weight of the enclosure, (brick or concrete is recommended). If the installer is in any doubt about the suitability of a site it is advised that he/she consult with an appropriately qualified Structural Engineer.  It is also important in determining the location of the case that space is allowed for access to the front, sides and beneath the equipment to enable maintenance work to be carried out. The door must be able to fully open but not to obstruct other equipment when doing so.  The location should ideally be served with steel conduits to carry all the cables to and from the case.  5.5 Electrical Connections  The mains power supply is connected to the IP65 connector located on the bottom/side surface of the case. It is recommended that the connection is made by a qualified electrician, who must satisfy himself that the supply will be the correct voltage and of sufficient capacity.  All electrical and RF connections should be completed and checked prior to power being applied for the first time.  5.6 RF Connections  Care must be taken to ensure that the correct connections are made with particular attention made to the base station Tx/Rx ports. In the event that the base transmitter is connected to the Rx output, damage to the equipment will be done if the base station transmitter is then keyed.  Ensure that connections are kept clean and are fully tightened.  5.7 RS232 Setup  The RS232 controller/monitor should not need setting up as the specified configuration will have been fully tested before it leaves the factory.  Further information on the controller board’s setup and remote capabilities is available in the RS232 Controller/Monitor Handbook, AFL N. 17-005801HBKM.
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-34 of 39   6. MAINTENANCE  6.1 General Procedures  6.1.1  Quick Fault Checklist  All AFL equipment is individually tested to specification prior to despatch. Failure of this type of equipment is not common. Experience has shown that a large number of fault conditions relating to new equipment have simple causes often occurring as a result of transportation, unpacking and installation. Below are listed some common problems which have resulted in poor performance or an indicated non-functioning of the equipment.  • Mains power not connected or not switched on. • External connectors not fitted or incorrectly fitted. • Internal connectors/ports becoming loose due to transport vibration. • Wiring becoming detached as a result of heavy handling. • Input signals not present due to faults in the aerial and feeder system. • Base transmissions not present due to faults at the base station. • Modems fitted with incorrect software configuration/and or PIN N’s. • Changes to channel frequencies and inhibiting channels. • Hand held radio equipment not correctly set to repeater channels. • Hand held radio equipment not correctly set to base station.  6.1.2 Fault Finding  In the event that the performance of the system is suspect, a methodical and logical approach to the problem will reveal the cause of the difficulty. The System consists of modules within a wall mounted, environmentally protected enclosure Transmissions from the main base stations are passed though the system to the mobile radio equipment; this could be a handheld radio or a transceiver in a vehicle. This path is referred to as the downlink. The return signal path from the mobile radio equipment to the base station is referred to as the uplink.  The first operation is to check the alarms of each of the active units and determine that the power supplies to the equipment are connected and active. This can be achieved remotely (via CEMS, the RS232 Coverage Enhancement Management System, if fitted), or locally with the front door LED’s. The green LED should be illuminated, while the red alarm indicator should be off. If the alarm LED is on, then the amplifier (or any other alarmed device connected to the summary output) that is causing the fault will have to be isolated and individually tested against the original test specification. The individual amplifier modules have a green LED showing through a hole in their lid/cover, which is illuminated if the unit is working correctly, and extinguished if not. If an amplifier is suspect, check the DC power supply to the unit. If no other fault is apparent use a spectrum analyser to measure the incoming signal level at the input and then after reconnecting the amplifier input, measure the output level. Consult with the system diagram to determine the expected gain and compare result.  In the event that there are no alarms on and all units appear to be functioning it will be necessary to test the system in a systematic manner to confirm correct operation.
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-35 of 39   6.1.3 Downlink  Confirm that there is a signal at the expected frequency and strength from the base station. If this is not present then the fault may lay outside the system. To confirm this, inject a downlink frequency signal from a known source at the master site BTS input and check for output at the remote site feeder output.  If a signal is not received at the output it will be necessary to follow the downlink path through the system to find a point at which the signal is lost. The expected downlink output for the given input can be found in the end-to-end test specification.   6.1.4 Uplink  Testing the uplink involves a similar procedure to the downlink except that the frequencies used are those transmitted by the mobile equipment.  6.1.5 Fault repair  Once a faulty component has been identified, a decision must be made on the appropriate course to carry out a repair. A competent engineer can quickly remedy typical faults such as faulty connections or cables. The exceptions to this are cable assemblies connecting bandpass filter assemblies that are manufactured to critical lengths to maintain a 50-ohm system. Care should be taken when replacing cables or connectors to ensure that items are of the correct specification. The repair of component modules such as amplifiers and bandpass filters will not usually be possible in the field, as they frequently require specialist knowledge and test equipment to ensure correct operation. It is recommended that items of this type are replaced with a spare unit and the faulty unit returned to AFL for repair.
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-36 of 39   6.1.6 Checking service  Following the repair of any part of the system it is recommended that a full end-to-end test is carried out in accordance with the test specification and that the coverage is checked by survey. It is important to bear in mind that the system includes a radiating cable network and base stations that may be faulty or may have been damaged.  6.1.7 Service Support  Advice and assistance with maintaining and servicing this system are available by contacting Aerial Facilities Ltd.   6.2 Tools & Test Equipment  The minimum tools and test equipment needed to successfully service this AFL product are as follows:-    Spectrum analyser:    100kHz to 2GHz (Dynamic range = 90dB).   Signal Generator:    30MHz to 2GHz (-120dBm to 0dBm o/p level).   Attenuator:      20dB, 10W, DC-2GHz, (N male – N female).   Test Antenna:     Yagi or dipole for operating frequency.   Digital multi-meter:    Universal Volt-Ohm-Amp meter.   Test cable x 2:     N male – N male, 2M long RG214.   Test cable x 2:     SMA male – N male, 1m long RG223.   Hand tools:      Philips #1&2 tip screwdriver. 3mm flat bladed screwdriver.      SMA spanner and torque setter.
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-37 of 39   6.3 Care of Modules  6.3.1 General Comments  Many of the active modules contain semiconductor devices utilising MOS technology, which can be damaged by electrostatic discharge. Correct handling of such modules is mandatory to ensure their long-term reliability.  To prevent damage to a module, it must be withdrawn/inserted with care. The module may have connectors on its underside, which might not be visible to the service operative.  6.3.2  Module Removal (LNA’s, general procedure):  The following general instructions should be followed to remove a module:  1  Remove power to the unit 2  Remove all visible connectors (RF, DC & alarm) 3  Release module retaining screws. 4  Slowly but firmly, pull the module straight out of its position. Take care not to twist/turn the module during withdrawal. (When the module is loose, care may be needed, as there may be concealed connections underneath).  6.3.3  Module Replacement (general):  1  Carefully align the module into its location then slowly push the module directly straight into its position, taking care not to twist/turn it during insertion. 2  Reconnect all connectors, RF, alarm, power etc.,(concealed connectors may have to be connected first). 3  Replace retaining screws (if any). 4  Double-check all connections before applying power.  6.3.4 Power Amplifiers  1)  Remove power to the unit. (Switch off @ mains/battery, or remove DC/alarm ‘D’ type connector)  2)  Remove alarm wires from alarm screw terminal block or disconnect multi-way alarm connector.  3)  Carefully disconnect the RF input and output coaxial connectors (usually SMA)  If alarm board removal is not required, go to step 5.  4)  There is (usually) a plate attached to the alarm board which fixes it to the amplifier, remove its retaining screws and the alarm board can be withdrawn from the amplifier in its entirety. On certain types of amplifier the alarm board is not mounted on a dedicated mounting plate; in this case it will have to firstly be removed by unscrewing it from the mounting pillars, in most cases, the pillars will not have not have to be removed before lifting the amplifier.
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-38 of 39   5)  If the amplifier to be removed has a heatsink attached, there may be several different ways it can have been assembled. The most commonly used method, is screws through the fins of the heatsink to threaded screw holes (or nuts and bolts), into the amplifier within the main case (side & top mounting). If the heatsink is mounted on the rear of the main case (this is very unusual), then the fixing method for the heatsink will be from within the case, otherwise the enclosure would have to be removed from the wall in order to remove the heatsink).  When the heatsink has been removed, the amplifier may be unscrewed from the main casing by its four corner fixings and gently withdrawn.  Fitting a new power amplifier module will be the exact reverse of the above.  Note:  Do not forget to apply fresh heatsink compound to the heatsink/main case joint and also between the amplifier and the main case.  6.3.5  Low Power Amplifier Replacement  1 Isolate the mains power supply and disconnect the DC supply connector for the LPA. 2 Disconnect the RF input and output cables from the LPA. 3 Disconnect the alarm connector. 4 Remove the alarm monitoring wires from (D type connector) pins 9 and 10. 5 Remove the LPA module by removing the four retaining screws, replace with a new LPA module and secure it with the screws. 6 Connect the RF cables to the LPA input and output connectors. Reconnect the wires to the alarm board connector pins 9 and 10. 7 Reconnect the DC supply connector and turn the mains switch on.  Note:  Tighten SMA connectors using only a dedicated SMA torque spanner. If SMA connectors are over-tightened, irreparable damage will occur. . Do not use adjustable pliers to loosen/tighten SMA connectors.  Also take care not to drop or knock the module as this can damage (or misalign in the case of tuned passive modules) sensitive internal components. Always store the modules in an environmentally friendly location  6.3.6 Module Transportation:  To maintain the operation, performance and reliability of any module it must be stored and transported correctly. Any module not installed in a whole system must be kept in an anti-static bag or container. These bags or containers are normally identified by being pink or black, and are often marked with an ESD label. Any module sent back to AFL for investigation/repair must be so protected. Please contact AFL’s quality department before returning a module.
Two Channel 400MHz Cell Enhancer User Handbook Handbook N.-50-128501HBK Issue No:-A Date:-12/08/2005  Page:-39 of 39  APPENDIX A  INITIAL EQUIPMENT SET-UP CALCULATIONS  GENERAL INFORMATION Site Name:    Client Name:   Date:    AFL Equip. Model N.   ANTENNA SYSTEMS  Model Gain  Azimuth  Comments A - Service Antenna       B – Donor Antenna        Type Loss  Length  Comments C – Service Feeder       D – Donor Feeder        INITIAL PARAMETERS E – CE Output Power  dBm F – Antenna Isolation  dB G – Input signal level from donor BTS  dBm Operating Voltage  V  DOWNLINK CALCULATIONS Parameter  Comments  Value Input signal level (G) dBmCE max. o/p power (E) dBmGain setting E - G  dBIsolation required (Gain + 10dB)  dBService antenna gain (A) dBService antenna feeder loss (C) dBEffective radiated power (ERP) E+A-C  dBmAttenuator setting CE gain-gain setting  dB If the input signal level in the uplink path is known and steady, use the following calculation table to determine the gain setting. If the CE features Automatic Gain Control the attenuator should be set to zero and if not, then the attenuation setting for both uplink and downlink should be similar.  UPLINK CALCULATIONS Parameter  Comments  Value Input signal level    dBmCE max. o/p power (E)   dBmGain setting    dBRequired isolation    dBDonor antenna gain (B)   dBDonor antenna feeder loss (D)   dBEffective radiated power (ERP)  E+B-D  dBmAttenuator setting  (CE gain-gain setting)  dB

Navigation menu