PBE Europe as Axell Wireless 60-1665SERIES UHF Remote Repeater type 60-166501 User Manual 60 166501HBKM

Axell Wireless UHF Remote Repeater type 60-166501 60 166501HBKM

User manual

Download: PBE Europe as Axell Wireless 60-1665SERIES UHF Remote Repeater type 60-166501 User Manual 60 166501HBKM
Mirror Download [FCC.gov]PBE Europe as Axell Wireless 60-1665SERIES UHF Remote Repeater type 60-166501 User Manual 60 166501HBKM
Document ID714764
Application IDptwtbXMNFw6IaosBU0ljcg==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize82.75kB (1034321 bits)
Date Submitted2006-10-12 00:00:00
Date Available2006-10-12 00:00:00
Creation Date2006-08-07 14:27:03
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2006-08-07 14:27:03
Document Title60-166501HBKM.pdf
Document CreatorPScript5.dll Version 5.2.2
Document Author: dwinstanley

Baltimore Transit
Radio Repeater System
User/Maintenance Handbook (2)
for
Intelect Corp.
AFL Works Order:
AFL product part No.:
Q113737
60-166501
Aerial Facilities Limited
Technical Literature
Baltimore Radio Repeater System
Maintenance Handbook
Handbook Number 60-166501HBKM
Issue No. A
Date 15/02/2006
Page 1 of 26
1.
INTRODUCTION
Scope and Purpose of this Document
This handbook is for use solely with the equipment identified by the AFL Part Number shown on the
front cover. It is not to be used with any other equipment unless specifically authorised by Aerial
Facilities Limited. This is a controlled release document and, as such, becomes a part of Aerial
Facilities’ Total Quality Management System. Alterations and modification may therefore only be
performed by Aerial Facilities Ltd.
AFL recommends that the installer of this equipment familiarise his/herself with the safety and
installation procedures contained within this document before installation commences.
The purpose of this handbook is to provide the user/maintainer with sufficient information to service
and repair the equipment to the level agreed. Maintenance and adjustments to any deeper level must
be performed by AFL, normally at the company’s repair facility in Chesham, England.
This handbook has been prepared in accordance with BS 4884, and AFL’s Quality procedures, which
maintain the company’s registration to BS EN ISO 9001:2000 and to the R&TTE Directive of the
European Parliament. Copies of the relevant certificates and the company Quality Manual can be
supplied on application to the Quality Manager.
This document fulfils the relevant requirements of Article 6 of the R&TTE Directive.
Limitation of Liability Notice
This manual is written for the use of technically competent operators/service persons. No liability is
accepted by AFL for use or misuse of this manual, the information contained therein, or the
consequences of any actions resulting from the use of the said information, including, but not limited
to, descriptive, procedural, typographical, arithmetical, or listing errors.
Furthermore, AFL does not warrant the absolute accuracy of the information contained within this
manual, or its completeness, fitness for purpose, or scope.
AFL has a policy of continuous product development and enhancement, and as such, reserves the
right to amend, alter, update and generally change the contents, appearance and pertinence of this
document without notice.
All AFL products carry a twelve month warranty from date of shipment. The warranty is expressly on a
return to base repair or exchange basis and the warranty cover does not extend to on-site repair or
complete unit exchange.
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 2 of 26
Table of Contents
1.
INTRODUCTION.......................................................................................................................... 2
Scope and Purpose of this Document................................................................................................. 2
Limitation of Liability Notice................................................................................................................. 2
2.
SAFETY CONSIDERATIONS ...................................................................................................... 4
2.1 Earthing of Equipment .............................................................................................................. 4
2.2 Electric Shock Hazard............................................................................................................... 4
2.3 RF Radiation Hazard ................................................................................................................ 4
2.4 Chemical Hazard ...................................................................................................................... 5
2.5 Laser safety .............................................................................................................................. 5
2.6 Emergency Contact Numbers................................................................................................... 5
3.
EQUIPMENT OVERVIEW/SPECIFICATIONS............................................................................. 6
3.1 Fibre Fed High Power Remote BDA (60-166501) .................................................................... 7
3.2
Fibre Fed High Power Remote BDA Description................................................................... 7
3.3
Fibre Fed High Power Remote BDA Technical Specifications .............................................. 7
3.4
Fibre Fed High Power Remote BDA Mechanical Specifications ........................................... 7
3.5
Fibre-Fed High Power Remote Site System Diagram, Drg. No. 60-166581.......................... 8
3.6
Fibre-Fed High Power Remote Site Alarm Diagram, Drg. Nǀ 60-166551 ............................. 9
3.7
Remote Site UHF BDA Alarm Wiring Diagram, Drg. No. 60-166551 .................................. 10
3.8
Remote Site UHF BDA Outline Drawing, Drg. No. 60-166591 ............................................ 11
3.9
Fibre Fed High Power Remote BDA Parts List (60-166501) ............................................... 13
4.
INSTALLATION & COMMISIONING.......................................................................................... 15
4.1 Initial Installation Record......................................................................................................... 15
4.2 Antenna Installation & Gain Calculations................................................................................ 15
4.3 Antenna Isolation .................................................................................................................... 16
4.4 Rack Mounted Equipment....................................................................................................... 17
4.5 Optical Connections................................................................................................................ 17
4.6 Wall Mounted Equipment........................................................................................................ 18
4.7 RF Connections ...................................................................................................................... 18
4.8 RF Commissioning.................................................................................................................. 18
5.
FAULT FINDING / MAINTENANCE ........................................................................................... 19
5.1 Tools & Test Equipment.......................................................................................................... 19
5.2 Basic Fault Finding ................................................................................................................. 19
5.3 Quick Fault Checklist .............................................................................................................. 20
5.4 Downlink ................................................................................................................................. 20
5.5 Uplink ...................................................................................................................................... 20
5.6 Fault repair.............................................................................................................................. 20
5.7 Service Support ...................................................................................................................... 20
5.8 Care of Modules...................................................................................................................... 21
5.9 Module Removal (LNAs, general procedure):......................................................................... 21
5.10
Module Replacement (general): .......................................................................................... 21
5.11
Power Amplifiers.................................................................................................................. 21
5.12
Low Power Amplifier Replacement...................................................................................... 22
5.13
Module Transportation:........................................................................................................ 22
6.1
6.2
6.3
6.4
APPENDIXES ............................................................................................................................ 23
Glossary of Terms used in this document............................................................................... 23
AFL RF Module Drawing Key ................................................................................................. 24
EC Declaration of Conformity ................................................................................................. 25
Amendment List Record Sheet ............................................................................................... 26
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 3 of 26
2.
SAFETY CONSIDERATIONS
2.1
Earthing of Equipment
Equipment supplied from the mains must be connected to grounded outlets and earthed
in conformity with appropriate local, national and international electricity supply and
safety regulations.
2.2
Electric Shock Hazard
The risk of electrical shocks due to faulty mains driven power supplies whilst
potentially ever present in any electrical equipment, would be minimised by adherence
to good installation practice and thorough testing at the following stages:
a)
Original assembly.
b)
Commissioning.
c)
Regular intervals, thereafter.
All test equipment must be in good working order prior to its use. High current power supplies can be
dangerous because of the possibility of substantial arcing. Always switch off during disconnection and
reconnection.
2.3
RF Radiation Hazard
RF radiation, (especially at UHF frequencies) arising from transmitter outputs
connected to AFL’s equipment, must be considered a safety hazard.
This condition might only occur in the event of cable disconnection, or because a
‘spare’ output has been left unterminated. Either of these conditions would impair the
system’s efficiency. No investigation should be carried out until all RF power sources have been
removed. This would always be a wise precaution, despite the severe mismatch between the
impedance of an N type connector at 50Ÿ, and that of free space at 377Ÿ, which would severely
mitigate against the efficient radiation of RF power. Radio frequency burns could also be a hazard, if
any RF power carrying components were to be carelessly touched!
Antenna positions should be chosen to comply with requirements (both local & statutory) regarding
exposure of personnel to RF radiation. When connected to an antenna, the unit is capable of
producing RF field strengths, which may exceed guideline safe values especially if used with
antennas having appreciable gain. In this regard the use of directional antennas with backscreens
and a strict site rule that personnel must remain behind the screen while the RF power is on, is
strongly recommended.
Where the equipment is used near power lines, or in association with temporary masts not having
lightning protection, the use of a safety earth connected to the case-earthing bolt is strongly advised.
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 4 of 26
2.4
Chemical Hazard
Beryllium Oxide, also known as Beryllium Monoxide, or Thermalox™, is sometimes
used in devices within equipment produced by Aerial Facilities Ltd. Beryllium oxide
dust can be toxic if inhaled, leading to chronic respiratory problems. It is harmless if
ingested or by contact.
Products that contain beryllium are load terminations (dummy loads) and some power amplifiers.
These products can be identified by a yellow and black “skull and crossbones” danger symbol (shown
above). They are marked as hazardous in line with international regulations, but pose no threat under
normal circumstances. Only if a component containing beryllium oxide has suffered catastrophic
failure, or exploded, will there be any danger of the formation of dust. Any dust that has been created
will be contained within the equipment module as long as the module remains sealed. For this reason,
any module carrying the yellow and black danger sign should not be opened. If the equipment is
suspected of failure, or is at the end of its life-cycle, it must be returned to Aerial Facilities Ltd for
disposal.
To return such equipment, please contact the Quality Department, who will give you a Returned
Materials Authorisation (RMA) number. Please quote this number on the packing documents, and on
all correspondence relating to the shipment.
PolyTetraFluoroEthylene, (P.T.F.E.) and P.T.F.E. Composite Materials
Many modules/components in AFL equipment contain P.T.F.E. as part of the RF insulation barrier.
This material should never be heated to the point where smoke or fumes are evolved. Any person
feeling drowsy after coming into contact with P.T.F.E. especially dust or fumes should seek medical
attention.
2.5 Laser safety
General good working practices adapted from
EN60825-2: 2004/ EC 60825-2:2004
Do not stare with unprotected eyes or with any unapproved optical device at the fibre
ends or connector faces or point them at other people, Use only approved filtered or
attenuating viewing aids.
Any single or multiple fibre end or ends found not to be terminated (for example, matched, spliced)
shall be individually or collectively covered when not being worked on. They shall not be readily
visible and sharp ends shall not be exposed.
When using test cords, the optical power source shall be the last connected and the first
disconnected.
Use only approved methods for cleaning and preparing optical fibres and optical connectors, do not
allow any dirt/foreign material ingress on the optical connector bulkheads and always keep optical
connectors covered to avoid physical damage.
The optical fibre jumper cable maximum bend radius is 3 cm (1 ¼" ), any smaller radii may result in
optical cable breakage or excessive transmission losses.
Caution: Do not get the Fibre Optic units wet, they are NOT weather proof.
2.6
Emergency Contact Numbers
The AFL Quality Department can be contacted on:
Telephone
+44 (0)1494 777000
Fax.
+44 (0)1494 777002
e-mail
mail to:qa@aerial.co.uk
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 5 of 26
3.
EQUIPMENT OVERVIEW/SPECIFICATIONS
The Baltimore repeater system consists of several items of hardware:Master Site Preston UHF Air Interface Channelised Amplifier (60-166101, rack mounting)
Master Site OCC UHF Air Interface Channelised Amplifier (60-166201, rack mounting)
Preston Six-Way Fibre Optic Master Site (60-166301, rack mounting)
OCC Six-Way Fibre Optic Master Site (60-166401, rack mounting)
Remote Site High Power UHF Bi-Directional Amplifier (60-166501, wall mounting)
MOCE Site Air Interface Repeater (60-166801, wall mounting)
6 x 114Ah Battery Backups (80-333201, wall mounting)
There are two master sites, one at PRESTON and one at OCC, each has a 19” rack cabinet
containing the four off-air receiving shelves, which also contain the power supplies and the DC/DC
converters (12V) for the FO shelf.
The master site equipment receives off-air transmissions which it channelises, (15 channels) and
sends this downlink signal data to six fibre optic RX modules. Remotely sited cell enhancers receive
this FO data, demodulate and amplify it and feed it to local LCX antennas.
At the remote sites, the same leaky feeder antennas receive mobile signals, band selectively amplify
them and send this uplink data back by FO to the master site where it is demodulated, channelised
and broadcast on the same air interface antenna that received the downlink signal.
Existing in the current system are bi-directional amplifiers in the 800MHz bands. These signals are
catered for using specialist cross-band couplers so that the 800MHz signals bypass the 490MHz
system path with negligible loss.
20dB couplers fitted at various points in the system ‘tap-off’ a signal suitable for monitoring the RF
power in any path.
Each active device is alarm monitored and these alarms are available either as separate volt-free
relay contact pairs, in groups (e.g. all downlink power amplifiers), or as an alarm summary of the
whole system with locally visible indications (LEDs).
Six 114Ah battery backup systems ensure no loss of coverage should mains power fail. At the time of
writing this document no information was available on which items of the system were to be fitted to
the battery backups.
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 6 of 26
3.1
3.2
Fibre Fed High Power Remote BDA (60-166501)
Fibre Fed High Power Remote BDA Description
The remote equipment is of two different types, an off-air repeater and a fibre fed repeater.
The optical repeater is directly linked to the master site by fibre optic cable and has a high power
downlink (40Watts) output to the LCX antennas. Both remote repeaters have an automatic gain
control loop in each path to lessen the overloading effects of a mobile operated close to the leaky
feeder antennas. This unit also has its own mains-to-DC power supply or ‘DC in’ (24V).
3.3
Fibre Fed High Power Remote BDA Technical Specifications
PARAMETER
Frequency range:
Bandwidth:
Manual Gain Adjustment:
Remote gain adjustment:
Downlink1dB Compression Point:
Downlink 3rd Order Intercept Point:
Uplink 1dB Compression Point:
Uplink 3rd Order Intercept Point:
Noise Figure:
Impedance:
RF Connectors:
Power Supply:
Power consumption:
operational:
Temperature range:
storage:
3.4
SPECIFICATION
494.3-495.3MHz (Downlink)
497.3-498.3MHz (Uplink)
1.0MHz
0-15dB (in 1dB steps)
0-15dB (in 1dB steps)
> +47dBm
> +63dBm
> +30.5dBm
> +44dBm
<6.0dB at any gain setting
50 ohms
N type, female
110V AC (nominal)
<8A ( @ 12V)
-10qC to +60qC
-40qC to +70qC
Fibre Fed High Power Remote BDA Mechanical Specifications
PARAMETER
SPECIFICATION
Height:
820mm
Case size
Width:
620mm
Depth:
250mm
(excluding heatsinks, connectors, handles and feet)
Fixings:
4 holes on 670(w) x 775(h)mm
operational:
-10°C to +60°C
Temperature range:
storage:
-40°C to +70°C
Weight:
60kg (approximately)
RF Connectors:
N type female
Environmental protection:
IP65 (with door closed and all ports terminated)
Case:
Semi-gloss grey (RAL 7035)
Finish:
Heatsinks:
Black anodised
Handles:
Black high impact technopolymer
Unit supplied with suitable supply input leads with
Supply Cable:
connector and appropriate length of cable
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 7 of 26
3.5
Fibre-Fed High Power Remote Site System Diagram, Drg. No. 60-166581
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 8 of 26
3.6
Fibre-Fed High Power Remote Site Alarm Diagram, Drg. Nǀ 60-166551
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 9 of 26
3.7
Remote Site UHF BDA Alarm Wiring Diagram, Drg. No. 60-166551
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 10 of 26
3.8
Remote Site UHF BDA Connections to NFM Diagram, Drg. No. 60-166552
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 11 of 26
3.9
Remote Site UHF BDA Outline Drawing, Drg. No. 60-166591
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 12 of 26
3.10 Fibre Fed High Power Remote BDA Parts List (60-166501)
part 1
AFL Part No. Part Description
02-007302
5 POLE SPECTRUM DIVIDING COMBLINE FILTER
02-013401
6 POLE SPECTRUM DIVIDING COMBLINE FILTER
05-002603
UHF 3dB SPLITTER
05-009001
4 WAY SPLITTER 380-960MHz
07-002902
POWER MONITOR 20dB OUTPUT 350-550MHz
07-002908
POWER MONITOR 30dB OUTPUT 350-550MHz
07-004814
CROSSBAND COUPLER 500/800MHz
07-014004
20dB DIRECTIONAL COUPLER
10-001205
REMOTE ATTENUATOR 0 - 15 dB
11-007302
LOW NOISE AMPLIFIER 20dB GAIN
12-021704
POWER AMPLIFIER (LINEARIZED ) 20W
12-021801
POWER AMPLIFIER 1W
13-001710
VOLTAGE REGULATOR BOARD
13-001803
DUAL DC/DC CONVERTER 24V-12V 1A
13-001822
COVER FOR DUAL DC/DC CONVERTER 24V-12V 1A
13-003301
MAINS FILTER 8AMP
17-000126
CELL ENHANCER ID LABEL
17-001109
AGC UNIT DETECTOR
17-001201
AGC UNIT ATTENUATOR
17-001528
BLANKING PLATE GASKET
17-009021
CELL ENHANCER BODY
17-009022
EQUIPMENT MOUNTING PLATE
17-013103
1" PROBE WITH RMS DETECTOR & 20dB COUPLER
20-001601
12V RELAY PCB
20-001602
24V RELAY PCB
20-004001
FIBRE OPTIC RF TRANSMITTER
20-004103
FIBRE OPTIC RF RECEIVER
80-031820
HEATSINK FOR 20W POWER AMPLIFIER
80-310420
HEATSINK FOR POWER SUPPLY
90-100010
MAINS LEAD '6 AMP' FOR USA
90-200004
DC I/P LEADS, FREE SOCKET
91-030002
N ADAPTOR PANEL FEMALE:FEMALE
91-130001
SMA ADAPTOR 'T' ALL FEMALE
91-500011
3 POLE PANEL PLUG SEALED IP68
91-500013
2 POLE PANEL PLUG SEALED IP68
91-500015
CAP FOR PANEL PLUG
91-500043
25 POLE PANEL PLUG SEALED IP68
91-510035
3 WAY MATE N LOK PLUG HOUSING
91-510037
25 POLE FREE SOCKET SEALED IP68
91-520032
MATE N LOK SOCKET CONTACT 20/14 AWG
91-520033
25 POLE CONNECTOR SOCKET CONTACTS
91-520034
25 POLE CONNECTOR PIN CONTACTS
91-600014
'D' 9 WAY SOCKET
91-640004
LARGE PIN FOR 'D' 7 WAY SOCKET
91-660001
'D' 7 WAY SOCKET
91-700008
5 WAY IDC CONNECTOR
91-800003
10 WAY KRONE MODULE
92-120009
M20 IP68 CABLE GLAND
93-930003
1W LOAD TERMINATION
96-110047
20A ATO FUSE
96-300054
POWER SUPPLY UNIT 400w
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Qty.
25
25
continued...
Page 13 of 26
Fibre Fed High Power Remote BDA Parts List (60-166501)
part 2
AFL Part No. Part Description
96-700034
LED RED 5mm IP67
96-700035
LED GREEN 5mm IP67
96-900018
AC TRIP SWITCH (5 AMP M.C.B.)
96-920037
THERMAL SWITCH 70c N/C 1A TO-220
97-000001
WALL MOUNTING BRACKET
97-300010
MAINS SUPPLY INPUT COVER
97-300028
DC SWITCH AND FUSE BOX
97-400010
BLACK PLASTIC HANDLE 50mm HIGH
97-900004
RUBBER FOOT FOR CELL ENHANCER
98-000001
FC/APC D-HOLE ADAPTOR ADA0004
98-500004
FC/APC-FC/APC FIBREOPTIC CABLE 0.5M
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Qty.
Page 14 of 26
4.
INSTALLATION & COMMISIONING
4.1
Initial Installation Record
When this equipment is initially commissioned, please use the equipment set-up record sheet in the
Appendices. This will help both the installation personnel and AFL should these figures be needed for
future reference or diagnosis.
4.2
Antenna Installation & Gain Calculations
Most Cell Enhancers require two antennas, one a highly directional Yagi or similar directed
towards the donor cell base station, and one a leaky feeder, omni-directional antenna or Yagi to cover
the area in which the mobiles are to be served.
The maximum gain at which the Cell Enhancer can be set is limited by the isolation that can
be achieved between these two antennas. Therefore when the antennas have been installed, inject a
signal (at a known power level) into one of them and measure the signal level received by the other
antenna on a spectrum analyser. The isolation can then be calculated as the difference between
these two figures. The gain in each path of the Cell Enhancer should be set at least 10 dB below this
figure, using the switched attenuators as described below in paragraph 5.
Now measure the received signal from the donor cell at the input to the Cell Enhancer (base
port). The gain of the Cell Enhancer downlink path should be set such that the donor site signal will
not overload the Cell Enhancer amplifiers. It is recommended that the input level should be less than 50dBm at the input of the Cell Enhancer (Base port). (This figure is assuming maximum gain, and
may be increased by the value of the attenuator fitted in the downlink path.)
Ensure that the mobile facing antenna has at least 70 dB isolation from the nearest mobile.
(This is normally easily achievable when using a leaky feeder antenna, but usually requires positional
adjustment when using a Yagi.)
The Cell Enhancer gain is fixed by setting the attenuation in each path (uplink and downlink)
between the first two amplifier stages (see markings within the Cell Enhancer or layout drawings for
the exact attenuator locations). Note that the uplink (mobile to base) and downlink (base to mobile)
path gains are set independently. This allows the paths to have different gains if required to set the
correct output power levels. The attenuation added into the path is a direct reflection of the active
switch positions, i.e. switch 2 (2dB) and switch 4 (8dB) would add 10dB into the path.
It is recommended that the gains are set such that the Downlink channel output levels from the
Cell Enhancer are typically +20dBm.
(Input level + Gain = Output level).
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 15 of 26
4.3
A).
Antenna Isolation
First set up the two antennas & measure the isolation between them.
Measure Isolation
between antennas
Yagi
Yagi or leaky feeder
Mobiles
Base site (donor)
B).
Install the Cell Enhancer with its gain set 10dB below the isolation figure obtained above.
Yagi or leaky feeder
Yagi
Base port
Mobile port
Cell Enhancer
Mobiles
Base site (donor)
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 16 of 26
4.4
Rack Mounted Equipment
The size and weight of the equipment racks mean that they represent a significant topple hazard
unless they are bolted to the floor though the mounting holes in the base of the unit. In the interests of
safety this should be done before any electrical, RF, or optical connections are made.
The equipment must be located on a flat, level surface that is made from a material suitable for
bearing the weight of the rack assemblies. If the installer is in any doubt about the suitability of a site it
is recommended that he consult with an appropriately qualified Structural Engineer.
It is important in determining the location of the rack within the room that space is allowed for access
to the front and rear of the equipment. To enable maintenance to be carried out, the front doors of
each rack must be able to open fully. In this AFL system, all RF, optical and power interfaces are
located on the rear panels of the shelves; the cable interfaces to external equipment, mains, LCX
feeds, fibre cables etc., is from the floor area.
It is recommended that the mains supply connection is made by a qualified electrician, who must
satisfy himself that the supply will be the correct voltage and of sufficient capacity.
All electrical, optical and RF connections should be completed and double checked prior to power
being applied for the first time.
4.5
Optical Connections
The optical input and output ports will be located on the appropriate E/O shelf as shown in the
rack layout drawing and the system layout drawing. The ports are supplied with a green plastic
cover, which must be removed prior to the connection of the fibre cable. Ensure that transmitter
and receiver fibre cable are identified to prevent misconnection. At the master site, the fibre
transmitters are in the downlink path with the receivers in the uplink. At remote sites the fibre
transmitters are in the uplink with the receivers in the downlink. Observe optical safety
precautions in section 1. when handling fibre optic components.
The individual fibre optic units are fitted with a pair of status indicators on their front panels. One is a
green LED, which indicates that the unit is connected to a 12 Volt DC power supply. This indicator is
common to both transmit and receive units. The second LED on the RX module indicates that the
laser is operating (transmitting). On the RX unit the second LED indicates that a laser-light signal is
being received.
When all the fibre connections are completed and power to each site is connected each fibre unit
must show two illuminated indicators.
Ensure that connections are kept clean and are fully tightened.
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 17 of 26
4.6
Wall Mounted Equipment
The procedure for installing and commissioning a wall-mounted Bi-Directional
Amplifier unit is generally as follows:
Fix the unit in the chosen position. Ensure the mounting site is a straight, smooth,
perpendicular surface (brick or concrete recommended). Mounting bracket centres/dimensions
will be found in the specifications section (3.3). After fixing, mechanically test the installation
before proceeding.
Fix the two antennas (antenna isolation should already have been performed see section 4.2)
and connect them to the BDA.
Connect a suitable mains and/or battery power supply to the unit.
Connect the alarm interface connectors.
Calculate the attenuation settings required for the uplink and the downlink paths, and set the
attenuators as described elsewhere in this document.
Double-check all RF and power connections before switching the BDA mains on with the
small switch located inside the unit on the lower right hand side of the case.
Alarms may not settle for several seconds after switch-on, but they should extinguish after a
short time (up to 15 seconds).
Make test calls via the equipment to ensure correct operation, if possible monitoring the signal levels
during these calls to ensure that the uplink and downlink RF levels are as anticipated.
4.7
RF Connections
Care must be taken to ensure that the correct connections are made with particular attention made to
the optical TX/RX ports.
Ensure that connections are kept clean and are fully tightened.
4.8
RF Commissioning
Once all connections are made the equipment is ready for commissioning.
To commission the system the test equipment detailed in Section 5.1 will be required.
Using the system diagrams and the end-to-end test specification, the equipment should be tested to
ensure correct operation.
On initial power up the system alarm indicators on the front panels of the equipment should be
checked. A red LED illuminated indicates a fault in that particular shelf that must be investigated
before proceeding with the commissioning. A green LED on each shelf illuminates, to indicate that the
power supply is connected to the shelf.
In the event that any part of the system does not function correctly as expected, check all connections
to ensure that they are to the correct port, that the interconnecting cables are not faulty and that they
are tightened. The majority of commissioning difficulties arise from problems with interconnecting
cables and connectors.
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 18 of 26
5.
FAULT FINDING / MAINTENANCE
5.1
Tools & Test Equipment
The minimum tools and test equipment needed to successfully service this AFL product are as
follows:Spectrum analyser:
Signal Generator:
Attenuator:
Test Antenna:
Digital multi-meter:
Test cable x 2:
Test cable x 2:
100kHz to 2GHz (Dynamic range = 90dB).
30MHz to 2GHz (-120dBm to 0dBm o/p level).
20dB, 10W, DC-2GHz, (N male – N female).
Yagi or dipole for operating frequency.
Universal Volt-Ohm-Amp meter.
N male – N male, 2M long RG214.
SMA male – N male, 1m long RG223.
Hand tools:
Philips #1&2 tip screwdriver.
3mm flat bladed screwdriver.
SMA spanner and torque setter.
5.2
Basic Fault Finding
In the event that the performance of the system is suspect, a methodical and logical approach to the
problem will reveal the cause of the difficulty. The system consists of separate modules in a wallmounted enclosure.
Transmissions from the main base stations are passed though the system to the mobile radio
equipment; this could be a handheld radio or a transceiver in a vehicle. This path is referred to as the
downlink. The return signal path from mobile radio equipment to the base station is referred to as the
uplink.
The first fault finding operation is to check the alarms of each of the active units and determine that
the power supplies to the equipment are connected and active.
This can be achieved remotely (via CEMS, the RS232 Coverage Enhancement Management System,
if fitted), or locally with the front panel LEDs. The green LED on the door should be illuminated, while
the red alarm indicator should be off. If an alarm is on, then that individual module must be isolated
and individually tested against the original test specification. The individual amplifier units have a
green LED showing through a hole in their cover/lid, which is illuminated if the unit is working
correctly. (Without active power supplies there can be no alarm LED indicators, however without DC
power, the fail-safe summary alarm system [normally closed relay contacts] will be an open circuit,
thereby activating any externally connected system.)
If an amplifier is suspect, check the DC power supply to the unit. If no other fault is apparent use a
spectrum analyser to measure the incoming signal level at the input and then after reconnecting the
amplifier input, measure the output level. Consult with the system diagram to determine the expected
gain and compare result.
In the event that there are no alarms on and all units appear to be functioning it will be necessary to
test the system in a systematic manner to confirm correct operation.
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 19 of 26
5.3
Quick Fault Checklist
All AFL equipment is individually tested to specification prior to despatch. Failure of this type of
equipment is not common. Experience has shown that a large number of fault conditions relating to
installations result from simple causes often occurring as result of transportation, unpacking and
installation. Below are listed some common problems which have resulted in poor performance or an
indicated non-functioning of the equipment.
Mains power not connected or not switched on.
External connectors not fitted or incorrectly fitted.
Internal connectors/ports becoming loose due to transport vibration.
Wiring becoming detached as a result of heavy handling.
Input signals not present due to faults in the aerial and feeder system.
Base transmissions not present due to faults at the base station.
Modems fitted with incorrect software configuration/and or PIN No.’s.
Changes to channel frequencies and inhibiting channels.
Hand held radio equipment not correctly set to repeater channels.
Hand held radio equipment not correctly set to base station.
5.4
Downlink
Confirm that there is a signal at the expected frequency and strength from the base station(s). If this is
not present then the fault may lay outside the system. To confirm this, inject a downlink frequency
signal from a known source at the master site BTS input and check for output at the remote site
feeder output.
If a signal is not received at the output it will be necessary to follow the downlink path through the
system to find a point at which the signal is lost.
5.5
Uplink
Testing etc. of the uplink paths is similar to the downlink paths, except for the frequencies involved.
5.6
Fault repair
Once a faulty component has been identified, a decision must be made on the appropriate course to
carry out a repair. A competent engineer can quickly remedy typical faults such as faulty connections
or cables. The exceptions to this are cable assemblies connecting bandpass filter assemblies
(duplexers) that are manufactured to critical lengths to maintain a 50-ohm system. Care should be
taken when replacing cables or connectors to ensure that items are of the correct specification. The
repair of component modules such as amplifiers and bandpass filters will not usually be possible in
the field, as they frequently require specialist knowledge and test equipment to ensure correct
operation. It is recommended that items of this type are replaced with a spare unit and the faulty unit
returned to AFL for repair.
Following the repair of any part of the system it is recommended that a full end-to-end test is carried
out in accordance with the test specification and that the coverage is checked by survey.
It is important to bear in mind that the system includes antennas and base stations that may be faulty
or may have been damaged.
5.7
Service Support
Advice and assistance with maintaining and servicing this system are available by contacting Aerial
Facilities Ltd.
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 20 of 26
5.8
Care of Modules
Many of the active modules contain semiconductor devices utilising MOS technology, which can be
damaged by electrostatic discharge. Correct handling of such modules is mandatory to ensure their
long-term reliability. Good engineering practices should be observed at all times.
To prevent damage to a module, it must be withdrawn/inserted with care.
5.9
Module Removal (LNAs, general procedure):
The following general rules should be followed to remove a module:
1)
2)
3)
4)
Remove power to the unit
Remove all connectors (RF, DC/alarm)
Release module retaining screws.
Slowly but firmly, pull the module straight out of its position. Take care not to twist/turn the
module during withdrawal.
5.10
1)
2)
3)
4)
Module Replacement (general):
Carefully align the module into its location then slowly push the module directly straight into its
position, taking care not to twist/turn it during insertion.
Reconnect all connectors, RF, alarm, power etc.
Replace retaining screws (if any).
Double-check all connections before applying power.
5.11
Power Amplifiers
1)
Remove power to the unit. (Switch off at mains/battery)
2)
Disconnect multi-way alarm ‘D’ type connector
3)
Carefully disconnect the RF input and output coaxial connectors (usually SMA)
4)
If the amplifier to be removed has a heatsink attached, there may be several different ways it
can have been assembled. The most commonly used method, is screws through the front of the
heatsink to threaded screw holes (or nuts and bolts), into the amplifier within the main case. If the
heatsink is mounted on the rear of the main case (e.g., against a wall in the case of wall mounted
enclosures), then the fixing method for the heatsink will be from within the case, (otherwise the
enclosure would have to be removed from the wall in order to remove the heatsink).
When the heatsink has been removed, the amplifier may be unscrewed from the main casing by its
four corner fixings and gently withdrawn.
Fitting a new power amplifier module will be the exact reverse of the above.
Note: Do not forget to apply fresh heatsink compound to the heatsink/main case joint and also
between the amplifier and the main case.
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 21 of 26
5.12
Low Power Amplifier Replacement
Disconnect the mains power supply and disconnect the 24V dc supply connector for the LPA.
Disconnect the RF input and output cables from the LPA.
Disconnect the alarm connector (D type connector).
Remove the LPA module by removing the four retaining screws, replace with a new LPA module and
secure it with the screws.
Connect the RF cables to the LPA input and output connectors. Reconnect the wires to the alarm
board connector pins 9 and 10.
Reconnect the DC supply connector and turn the mains switch on.
Note: Tighten SMA connectors using only a dedicated SMA torque spanner. If SMA connectors are
over-tightened, irreparable damage will occur. . Do not use adjustable pliers to loosen/tighten SMA
connectors.
Also take care not to drop or knock the module as this can damage (or misalign in the case of tuned
passive modules) sensitive internal components. Always store the modules in an environmentally
friendly location
Test equipment should always be used to verify the performance of any new module fitted to the
system before broadcasting in the public domain.
5.13
Module Transportation:
To maintain the operation, performance and reliability of any module it must be stored and
transported correctly. Any module not installed in a whole system must be kept in an anti-static bag or
container. Any module sent back to AFL for investigation/repair must be so protected. Please contact
AFL’s quality department before returning a module.
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 22 of 26
6
APPENDIXES
6.1
Glossary of Terms used in this document
Repeater or
Cell Enhancer
Band Selective
Repeater
Channel Selective
Repeater
AC
AGC
BBU
BTS
CEMS
C/NR
DAB
DC
Downlink (D/L)
FO
GND
ID
LED
LCX
LNA
LPA
MOU
M/S
MS
MTBF
N/A
N/C
OFR
OIP3
PA
RF
RSA
RX
S/N
TTL
TX
Uplink (U/L)
VSWR
WDM
A Radio Frequency amplifier which can simultaneously amplify and rebroadcast Mobile Station and Base Transceiver Station signals.
A Cell Enhancer designed for operation on a range of channels within a
specified frequency band.
A Cell Enhancer, designed for operation on specified channel(s) within a
specified frequency band. Channel frequencies may be factory set or onsite programmable.
Alternating Current
Automatic Gain Control
Battery Backup Unit
Base Transceiver Station
Coverage Enhancement Management System
Carrier-to-Noise Ratio
Digital Audio Broadcasting
Direct Current
RF signals RX from the BTS to the Master Site
Fibre Optic
Ground
Identification Number
Light Emitting Diode
Coaxial Leaky Feeder
Low Noise Amplifier
Low Power Amplifier
Master Optical Unit
Master Site
Mobile Station
Mean Time Between Failures
Not Applicable
No Connection
On Frequency Repeater
Output Third Order Intercept Point = RFout +(C/I)/2
Power Amplifier
Radio Frequency
Receiver/Splitter Amplifier
Receiver
Serial Number
Transistor-Transistor Logic, a common type of digital circuit.
Transmitter
RF signals transmitted from the MS to the BTS
Voltage Standing Wave Ratio
Wave division multiplex
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 23 of 26
6.2
AFL RF Module Drawing Key
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 24 of 26
6.3
EC Declaration of Conformity
In accordance with BS EN ISO/IEC 17050-1&-2:2004
Aerial Facilities Limited
Aerial House
Asheridge Road
Chesham
Buckinghamshire HP5 2QD
United Kingdom
DECLARES, UNDER OUR SOLE RESPONSIBILITY THAT THE FOLLOWING PRODUCT:
PRODUCT PART NO[S]
PRODUCT DESCRIPTION
60-166501
Baltimore Transit radio repeaters
IN ACCORDANCE WITH THE FOLLOWING DIRECTIVES:
1999/5/EC
The Radio & Telecommunications Terminal Equipment Directive Annex V and
its amending directives
HAS BEEN DESIGNED AND MANUFACTURED TO THE FOLLOWING STANDARD[S] OR OTHER
NORMATIVE DOCUMENT[S]:
BS EN 60950
Information technology equipment.
Safety. General requirements
ETS EN 301 489-1
EMC standard for radio equipment and services.
Part 1. Common technical requirements
I hereby declare that the equipment named above has been designed to comply with the relevant
sections of the above referenced specifications. The unit complies with all essential requirements of
the Directives.
SIGNED
B S BARTON
TECHNICAL DIRECTOR
DATE: 16/02/2006
Registered Office: Aerial House, Asheridge Road, Chesham, Buckinghamshire, HP5 2QD England Registered No. 4042808 (England)
www.aerialfacilities.com
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 25 of 26
6.4
Issue
No.
Amendment List Record Sheet
Date
09/02/2006
Incorporated
by
CMH
CMH
Page Nos.
Amended
Reason for new issue
1st Draft
1st Issue
Document Ref:- 60-166501HBKM
Maintenance Handbook
Baltimore Radio Repeater System
Handbook No. 60-166501HBKM
Page 26 of 26

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 26
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:a36b582e-f36a-4a8f-84ac-fb4bad6220d1
Producer                        : Acrobat Distiller 6.0 (Windows)
Create Date                     : 2006:08:07 14:27:03+01:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2006:08:07 14:27:03+01:00
Document ID                     : uuid:e4234072-6a22-41d5-976f-5a899ea3c099
Format                          : application/pdf
Creator                         : dwinstanley
Title                           : 60-166501HBKM.pdf
Author                          : dwinstanley
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NEO60-1665SERIES

Navigation menu