PDI Communication System CV26 Hospital Grade LCD TV Receiver User Manual Purpose

PDI Communication System, Inc. Hospital Grade LCD TV Receiver Purpose

Users manual

Download: PDI Communication System CV26 Hospital Grade LCD TV Receiver User Manual Purpose
Mirror Download [FCC.gov]PDI Communication System CV26 Hospital Grade LCD TV Receiver User Manual Purpose
Document ID1312770
Application IDVoXlrAUyBehWfYuohFjLag==
Document DescriptionUsers manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize45.16kB (564531 bits)
Date Submitted2010-07-16 00:00:00
Date Available2010-07-16 00:00:00
Creation Date2010-04-05 14:03:26
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2010-07-13 18:19:48
Document TitlePurpose:
Document CreatorAcrobat PDFMaker 7.0 for Word
Document Author: Norman Mau

Page 1 of 11
WARNINGS
This symbol is intended to alert the user of the
presence of un-insulated ‘dangerous voltage’ within
the product’s enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to
persons.
This symbol is intended to alert the user of the
presence of important operating and maintenance
(servicing) instructions in the literature
accompanying the appliance.
NOTE TO CABLE TV INSTALLER
This reminder is provided to call the cable TV systems installer’s
attention to Article 820-40 of the National Electrical Code. The
code provides guidelines for proper grounding and, in particular,
specifies that the cable ground shall be connected to the
grounding system of the building, as close to the point of the
cable entry as practical.
FCC
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is
operated in a residential or commercial installation. If this
equipment does cause harmful interference to radio or TV
reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference
by one of more of the following measures:
ƒ Reorient or relocate the receiving antenna.
ƒ Increase the separation between the equipment and
receiver.
ƒ Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
ƒ Consult the dealer or an experienced radio/TV technician
for help.
SAFETY INSTRUCTIONS
MAINTENANCE AND SERVICING
Servicing is required when the apparatus has
been damaged in any way: the power cord or
plug is damaged, liquid has been spilled,
objects have fallen into the apparatus, the
apparatus has been exposed to rain or
moisture, it does not operate normally, or it
has been dropped.
Never remove the back cover of the TV; this
can expose you to high voltage and other
hazards. If the TV does not operate properly,
unplug it and call an authorized service
center.
POWER CORD
Protect the power cord from being walked on
or pinched particularly at the plugs,
convenience receptacles, and the point where
it exits from the apparatus.
CAUTION: DO NOT defeat the safety
purpose of the polarized or grounding-type
plug. A polarized plug has two blades with
one wider than the other. A grounding
type plug has two plates and a third
grounding prong. The wide blade or the
third prong is provided for your safety. If
the provided plug does not fit into your
outlet, consult an electrician for
replacement of the obsolete outlet.
RAIN AND MOISTURE
WARNING: To avoid the hazards of fire or
electrical shock, DO NOT expose this TV to
rain or moisture.
WET LOCATION
The apparatus SHOULD NOT be exposed to
dripping or splashing. Objects filled with
liquids, such as vases, SHOULD NOT be
placed on the apparatus.
OXYGEN ENVIRONMENT
WARNING: DO NOT use in an oxygen tent
or an oxygen chamber. Such use may cause
a fire hazard.
CLEANING AND DISINFECTION
Clean the exterior of this TV by removing
dust with a lint-free cloth.
INSTRUCTIONS
Be sure to read, follow, and keep these instructions. Heed all the
warnings.
CAUTION: To avoid damage to the surface
of the TV, DO NOT use abrasive or chemical
cleaning agents. Clean only with a dry cloth.
OTHER EQUIPMENT
Use only with the cart, stand, tripod, bracket or table specified by
the manufacturer or sold with the apparatus. Use caution when
moving the cart / apparatus combination to avoid injury from tipover.
DISCONNECTING DEVICE FROM MAINS
The main plug is the disconnecting device.
CAUTION: Unplug this apparatus during
lightning storms or when unused for long
periods of time.
PRODUCT MODIFICATION
DO NOT attempt to modify this product in
any way without written authorization.
Unauthorized modification could void the
user’s authority to operate this product.
OVERHEAD FALLING HAZARD
WARNING: To prevent injury, this apparatus
must be securely attached to the wall in
accordance with the installation instructions.
TVs can pose a striking hazard when
mounted at an elevated position.
Changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
Page 2 of 11
Copyright, Disclaimer, & Trademarks
COPYRIGHT
Clear View Communication Systems, Inc. claims proprietary right to the material disclosed in this user guide. This guide
is issued for user information only and may not be used to manufacture anything shown herein. Copyright 2009 by Clear
View. All rights reserved.
DISCLAIMER
The author and publisher have used their best efforts in preparing this guide. Clear View Communication Systems, Inc.
makes no representation or warranties with respect to the accuracy or completeness of the content of this guide and
specifically disclaim any implied warranties or merchantability or fitness for any particular purpose and shall in no event
be liable for any loss of profit or any other damages. The information contained herein is believed to be accurate, but is
not warranted, and is subject to change without notice or obligation.
TRADEMARKS
Manufactured under license from Dolby Laboratories. Dolby and the double-D symbol are trademarks of Dolby
Laboratories.
All other brand names and product names used in this guide are trademarks, registered trademarks, or trade names of
their respective holders. Clear View and Better Solutions Are Within Reach are registered trademarks of Clear View.
LOCATION GUIDELINES
The model CLEAR VIEW-LCD TV is intended for entertainment and educational purposes in a hospital, a nursing home,
medical-care center, or similar health-care facility in which installation is limited to a non-hazardous area in accordance
with the National Electrical Code, ANSI/NFPA 70. The CLEAR VIEW-CV26/32 designed for mounting to CLEAR VIEW
manufactured mounts. Installation of the TV on any other mount is not recommended.
WARNING: The TV’s VESA mounting holes are designed
for M4 and/or M6 metric screws only. Use of a non-CLEAR
VIEW approved mount or SAE hardware could result in a
condition where the TV could unexpectedly fall and cause
injury or death.
The CLEAR VIEW-CV26/32 mounts on the wall at the foot of a patient’s bed. Select a location that is near an AC wall
outlet and that does not expose the TV to bright room lights or sunlight, if possible. The LCD TV also requires connection
of both CATV cable signal and across-room wiring for the pillow speaker.
CABLE SYSTEM GROUNDING
The coax cable system connected to the CLEAR VIEW-CV26/32 should be grounded in accordance with the National
Electrical Code, ANSI/NFPA 70. The code provides guidelines for proper grounding and, in particular, specifies that the
cable ground shall be connected to the grounding system of the building, as close to the point of the cable entry as
practical.
Page 3 of 11
CONTROLS
Right Side Panel
1.
TV/AV button
Selects the video mode.
2.
CC button
Set the caption function.
3.
CH ▲/▼ buttons
Selects a program or a menu item.
4.
VOL ▲/▼ buttons
Adjusts the volume. Adjusts menu settings.
5.
POWER button
Switches TV set on or off.
Page 4 of 11
Rear Panel
1.
PILLOW
Moving this switch changes the voltage supplied to
Pillow speaker port.
the pillow speaker.
Use the switch to select correct voltage.
Make sure it is set correctly BEFORE plugging in the
CZ: Zenith Compatible (+14V)
pillow speaker jumper cable.
CP: Philips Compatible (+5V)
Failure to do so WILL RESULT IN THE PILLOW
CR: RCA Compatible (-5V)
SPEAKER BEING OVERDRIVEN AND POSSIBLE
Off: Pillow port disable (0V)
NOTES:
DAMAGE TO THE PILLOW SPEAKER.
2.
CCI
Communication port.
Page 5 of 11
3.
MTI
9.
10. COMPOSITE/S-VIDEO IN
4.
Connect to MTI device.
Note: CCI and MTI can not be connected to the
external public network, and can be used by the
technician only.
VGA IN
Connection to the video output jack on your PC.
5.
7.
or S-VIDEO VCR to the L & R IN of the set.
11. COMPONENT1 IN
sockets of the DVD to the COMPONENT audio/video
SD Card Slot
input sockets of the set.
12. COMPONENT2 IN
HDMI Jacks
Connect the COMPONENT audio/video output
Connection for HDMI device.
sockets of the DVD to the COMPONENT audio/video
COMPOSITE OUT
COAXIAL Jack
Provides a digital audio output signal for connection
to an external digital audio device.
Front Panel
Color TFT screen
2.
Speakers
3.
Power Indicator
Illuminates in red when the TV is off.
Illuminates in green when the TV is switched on.
4.
Connect the audio cable from the external equipment
Connect the COMPONENT audio/video output
equipment to this input.
1.
equipment to this input.
IN of the set.
Connect the Video/Audio inputs of external
8.
Connect the Video/S-VIDEO outputs of external
Connect the audio cable from the PC to the AUDIO
Firmware upgrading purpose.
6.
Power Supply Cord
Remote Sensor
Accepts the IR signal of remote controller.
input sockets of the set.
13. ANT TV/FM Jack
Connection to TV/FM antenna.
Page 6 of 11
Wall MOUNTING STANDARD WALL BRACKET for CLEAR VIEW-P26LCD TV
The CLEAR VIEW-CV26LCD TV is mounted to the wall with a PD168-103 mount (Not supplied with TV) or a PD168203 mount (Not supplied with TV). The PD168-203 mount is a heavy duty mount and is to be used if a DVD or an IPT
module is going to be mounted on the P26. A PD168-203 wall mount connects to a PD181-674 LCD mount. A PD168-103
wall mount connects to a PD181-597 LCD mount.
Mounting Pieces
Wall
Mount
LCD
Mount
Purpose
PD168-103
PD181-597
PD168-203
PD181-674
For mounting CV26
LCD TV to wall
without DVD
and/or IPT
Modules (1)
For mounting CV26
LCD TV to wall
with DVD and/or
IPT Modules (1)
Screws
Part #
Part
10-32 X ½ Pilfer
PDIPPBHSCS103250
Proof PIH Button
Head (2)
M4-.7 X 6MM
PDIPPHMSM4X76
PPHMS (4)
Numbers in parenthesis represent quantity
1. Refer to Figure 1. Select a location on the wall
approximately 9 inches below the ceiling.
NOTE: DO NOT locate AC, Across-Room
Wiring, and CATV Signal outlets below the
Wall Bracket’s location as it will cause
clearance issues and interfere with the TV’s
cabinet when mounted to the bracket.
2. Position the wallmount and locate the two
mounting holes. Secure the bracket to the wall
(mounting hardware is not included).
3. Refer to Figure 2. Position the LCD mount on
the LCD TV cabinet.
Mounting Connections
Figure 2
Back Mount
M6 x 10mm
Screws (4)
Pilfer Screws (2)
Wall
Mount
Attach with the four M4 screws (PDIPPHMSM4X76) that
are provided.
4. Mate the LCD mount to the wall mount, making sure the
pivot pins are retained in the slots.
5. Secure with two 10x32 Pilfer screws
(PDIPPBHSCS103250).
6. The TV’s tilt can be adjusted by loosening both Pilfer
screws, adjusting tilt, and then tightening the screws.
Page 7 of 11
Wall Mounting for CLEAR VIEW-CV32LCD TV
The CLEAR VIEW-CV32LCD require a PD181-672 200mm to 100mm Adapter Plate (Not supplied with TV), a PD181-596 LCD
Mounting Bracket (Not supplied with TV), and a PD181-674 HD Extended LCD Tilt Clevis (Not supplied with TV) to be mounted to
the wall.
1.
Refer to Figure 1. For the CLEAR VIEW-CV32LCD find a
location on the wall 10.5 inches below the ceiling to mount
the HD Extended LCD Tilt Clevis (wall mount).
NOTE: DO NOT locate AC, Across-Room
Wiring, and CATV Signal outlets below the
Wall Bracket’s location as it will cause
clearance issues and interfere with the TV’s
cabinet when mounted to the bracket.
2.
3.
Position the HD Extended LCD Tilt Clevis and locate two
mounting holes. Place one of the supplied ¼” flat washers
(CLEAR VIEWFW25) and the ¼” lock washer (CLEAR
VIEWSLW25) on a ¼” screw (not included) and insert it into
the top mounting hole of the clevis. Secure the clevis to the
wall. Place the other supplied ¼” flat washer on another ¼”
screw and insert it in the bottom mounting hole. Secure it to
the wall and tighten both screws.
Refer to Figure 2. Attach the LCD mount to adapter plate
using the four M4 screws (CLEAR VIEWPPHMSM4X76)
and four #10 Internal Tooth Lock washers (CLEAR
VIEWITLW10).
NOTE: The side with the four hex sides will
go toward the back of the set.
4.
Position the mounting bracket and adapter plate on the LCD
TV cabinet. Attach with the four M6 screws (CLEAR
VIEWPPHMSM6X110) that are provided.
5.
6.
Mate the mounting bracket to the clevis making sure
the resting pins are inserted in the two notches at the
front of the clevis. Secure with the two 10x32 screws
(PDIPPHMS103238) and the two remaining Internal
Tooth Lock washers.
The TV’s tilt can be adjusted by loosening both Pilfer
Screws, adjusting tilt, and then tightening the screws.
Mounting Connections
Mounting Pieces
Part #
Part
200mm to
100mm
PD181-672
Adapter Plate
(1)
LCD Mounting
PD181-596
Bracket (1)
HD Extended
PD181-674
LCD Tilt Clevis
(1)
Screws and Washers
CLEAR
10-32X3/8
VIEWPPHMS1
PPHMS (2)
03238
#10 Internal
CLEAR
Tooth Lock
VIEWITLW10
Washer (6)
CLEAR
M4-.7X6mm
VIEWPPHMSM
PPHMS (4)
4X76
Figure 2
PD181-596: LCD
Mounting Bracket
PD181-674: HD Extended
LCD Tilt Clevis
PD181-672: 200mm to
100mm Adapter Plate
CLEAR
VIEWPPHMSM
6X110
M6-1X10mm
PPHMS (4)
CLEAR
VIEWFW25
¼” flat washer
(2)
CLEAR
¼” lock
VIEWSLW25
washer (1)
Numbers in parenthesis represent
quantity
Page 8 of 11
Pillow speaker
A ¼” stereo-style pillow speaker (pendant control) jack is located on the TV’s connector panel on the backside. This TV is designed to
work with either a digital pillow speaker that generates digital-style control codes or a single-button analog (switch-style) pillow
speaker. A rear panel mounted switch allows use of different brands of pillow speakers and supports the major brands: Zenith, Philips,
and RCA.
CAUTION: Confirm the pillow speaker type and set the side switch appropriately
BEFORE connecting the pillow speaker to the TV. Failure to follow this procedure could
result in damage to the pillow speaker and/or TV.
Pillow Speaker and Antenna Connection
CAUTION: Some hospital
cable systems provide
power voltage on the coaxial
cable. This TV is NOT
designed to be powered via
a coaxial cable. DO NOT
connect to a powered
coaxial cable. Damage will
result to the TV.
Across-Room Wiring
NOTE: A Jumper Cable is NOT supplied with the TV and must be ordered separately.
SPEAKER
¼” to ¼” Jumper Cable
PD106-417
¼” to 6-Pin Jumper Cable
PD106-416
DATA / SWITCH
SPEAKER
COMMON
COMMON
DATA / SWITCH
ACROSS ROOM WIRING
WARNING: DO NOT connect
the pillow speaker circuit
Common to earth ground.
Grounding of the Common will
defeat the isolation circuitry of
the TV and possibly expose the
patient to harmful shock
currents should a wiring fault
occur.
Programming
A programming remote control (PD108-420) is used to perform all setup operations for the TV.
Page 9 of 11
NOTE: The following instructions assume you have correctly mounted the TV, wired an external pillow speaker, and connected
an RF coax cable signal, and AC power cord to the TV.
Service Levels Setup
The CLEAR VIEW-CV26/32 contains four separate service levels, allowing the hospital to offer basic and enhanced viewing. The
current service level can be quickly determined by accessing the SETUP menu using the remote control. Service Level can be
changed to any of the 4 levels at any time by entering the SETUP menu and changing the Service Level setting.
DISABLED – This is like a mechanical key lock. The TV
can be turned OFF and ON, but cannot be used for viewing
programs. A standard message appears on a black
screen.
FREE – This lets patients watch hospital education and
information channels without renting the TV. The channels
containing programming for no charge are typically
programmed into this level of service. This is the factory
default setting for Service Level.
BASIC – This service typically allows additional channels
beyond those offered in the FREE level.
PREMIUM – This is the highest service level with typically
the most channels available for viewing.
Signal
Four different tuning types are available depending upon the healthcare facility’s signal style. Selection of the correct signal type is
required for the TV to recognize all possible channels and before any channel programming can begin.
1.
2.
3.
4.
5.
6.
Press SETUP
Press CH▲ or CH▼ to highlight Channels.
Press VOL► to enter the Channels menu.
Press CH▲ or CH▼ to highlight Signal.
Press VOL◄ or VOL► to select Air, Cable STD, Cable IRC, or Cable HRC.
NOTE: Most hospitals use the Cable STD signal style.
Now perform Auto Program or Add/Delete Channels to adjust the channels.
Page 10 of 11
Auto Program
The TV automatically scans each available channel for activity. Channels that display activity are memorized into the selected Service
Level.
1.
2.
3.
After setting Signal, press CH▲ or CH▼ to highlight Auto Program.
Press VOL► to select it.
On Mode, press VOL◄ or VOL► to select the scope of channel scanning.
ƒ
Analog Only: TV searches for analog channels only.
ƒ
Digital Only: TV searches for digital channels only.
ƒ
Analog and Digital: TV searches for both analog and digital channels.
4. Press CH▲ or CH▼ to highlight Channel Sequence.
5. Press VOL◄ or VOL► to select the channel sequence in which the channels are displayed.
ƒ
Interleave A+D: Channels are displayed in the order of channel number.
ƒ
All A then D: All digital channels are displayed after all analog channels.
6. If you want to allow the TV to program additional digital channels, press CH▲ or CH▼ to highlight Add. Digital
Signal. Press VOL◄ or VOL► to select Air.
NOTE: This feature is only available if Mode is set to Digital Only or Analog and Digital.
7. Press CH▲ or CH▼ to highlight the Service Level (Free, Basic, or Premium) you wish to program. The menu
displays the current programming status of each level as either Programmed or Blank.
NOTE: A programmed service level can also be reprogrammed if desired.
8. Press VOL► to start auto programming.
9. A confirmation menu will appear before proceeding. Press CH▲ to start auto programming. Press CH▼ to
cancel the operation. The TV now will search all available channels. Auto programming requires several
minutes to complete.
NOTE: Digital channel auto programming may take longer than 10 minutes to complete.
10. Press SETUP to return to the previous menu. To exit, press SETUP until the programming menus disappear.
Page 11 of 11
Internal Speaker Enabled
The speakers inside the TV’s cabinet normally are enabled. Sound is also routed externally to an attached pillow speaker.
1.
2.
3.
4.
Enter the Sound menu
Press CH▲ or CH▼ to highlight the component you want to change.
Press VOL◄ or VOL► to select Enabled or Disabled.
Press SETUP to return to the previous menu.
Minimum Volume
This sets the minimum volume level the TV can reach. For pillow speakers with an adjustment thumbwheel volume control, ALWAYS
set a minimum volume level for the TV. A minimum volume setting is usually not required for pillow speakers with dedicated Volume
Up and Down buttons.
NOTE: Setting this level to any value other than 0 guarantees that some level of sound will always be heard when
the TV is operating.
1.
2.
3.
In the Sound menu, press CH▲ or CH▼ to highlight Minimum Volume.
Press VOL◄ or VOL► to select the preferred minimum volume.
Press the SETUP button to return to the preceding menu.
Power on Volume
This sets the initial volume the TV starts at upon powering on. Once the TV is on, the volume can be set to any allowable level.
In Sound menu, press CH▲ or CH▼ to highlight Power on Volume.
1. Press VOL◄ or VOL► to select the preferred volume when the TV turns on.
NOTE: Setting the level to LAST causes the TV to remember the last volume level used by the TV prior to turning off.
2. Press the SETUP button to return to the preceding menu.
Cloning
Cloning allows quick programming of a TV. Cloning instructions can be found on the Clear View Communication web site:
http://www.Clear Viewarm.com/support/
Click on the Firmware and Driver link and follow the on-screen instructions to find your TV model.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Company                         : PDi Communication Systems, Inc.
Source Modified                 : D:20100405180245
Create Date                     : 2010:04:05 14:03:26-04:00
Creator Tool                    : Acrobat PDFMaker 7.0 for Word
Modify Date                     : 2010:07:13 18:19:48+08:00
Metadata Date                   : 2010:07:13 18:19:48+08:00
Document ID                     : uuid:b3cef378-09c9-4471-861b-209004edb6d7
Instance ID                     : uuid:db0f6076-a2a3-4b53-bb61-0a579a43bfec
Version ID                      : 4
Format                          : application/pdf
Title                           : Purpose:
Creator                         : Norman Mau
Subject                         : 
Headline                        : 
Page Count                      : 11
Page Layout                     : OneColumn
Author                          : Norman Mau
EXIF Metadata provided by EXIF.tools
FCC ID Filing: WQ5CV26

Navigation menu