PECO SW206 Wireless Door/Window Sensor User Manual P1

PECO Inc. Wireless Door/Window Sensor P1

User Manual

Download: PECO SW206 Wireless Door/Window Sensor User Manual P1
Mirror Download [FCC.gov]PECO SW206 Wireless Door/Window Sensor User Manual P1
Document ID1404967
Application IDHaF9pbkjoHvpBAN02xr/xg==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize37.29kB (466086 bits)
Date Submitted2011-01-14 00:00:00
Date Available2011-01-14 00:00:00
Creation Date2010-12-23 10:19:41
Producing SoftwarePDF-XChange Viewer [Version: 2.0 (Build 54.0) (Jul 12 2010; 13:12:40)]
Document Lastmod2011-01-13 16:36:30
Document TitleP1
Document CreatorAdobe Illustrator CS2

SW206 Wireless Door/Window Sensor
SPECIFICATIONS
Power supply
Magnet operation
Radio frequency
Radio range
Radio modulation
Temperature limit
Humidity
Dimensions
INTRODUCTION
Installation Guide
! WARNING
▲
2 x AAA alkaline battery / 1.5 V Nominal (1200MAH)
Maximum 3/4“ inch (2 cm) from sensor for closed switch
902-928 MHz
100 feet (30.5 m) line of sight at open field
Frequency Hopping Spread Spectrum (FHSS)
-10°C~50°C (-14°F ~ 122°F)
95% RH maximum
4.8” x 1.1” x .78” (123.5 x 29 x 20 mm)
• READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL,
OPERATE OR SERVICE THIS DEVICE.
• Failure to observe safety information and comply with instructions could result in
PERSONAL INJURY, DEATH AND/OR PROPERTY DAMAGE.
• To avoid electrical shock or damage to equipment, disconnect power to all
devices before installing or servicing.
• To avoid potential fire and/ or explosion do not use in potentially flammable or
explosive atmospheres.
• Retain these instructions for future reference. This product, when installed,
will be part of an engineered system whose specifications and performance
characteristics are not designed or controlled by PECO, Inc. You must review
your application and national and local codes to assure that your installation will
be functional and safe.
Wireless Pairing
• PECO recommends completing the pairing process before mounting the sensor.
• To ensure successful pairing, refer to pairing instructions for the RW205 Receiver.
The SW206 Sensor must be paired with the RW205 Receiver. Wireless pairing enables the
associated RW205 Receiver to receive a radio signal from the SW206 Sensor.
1. To begin pairing, remove the front cover of the SW206 Sensor (see Fig. 1).
2. Place two AAA batteries in the SW206 Sensor battery compartment.
3. On the SW206 Sensor, press and hold the pairing switch (see Fig. 1) for about five
seconds. The corresponding LED indicator on the RW205 Receiver will begin flashing.
After the sensor has been successfully paired with the RW205 Receiver,
the corresponding LED on the RW205 Receiver will remain lit.
Thank you for choosing the PECO® SW206 Wireless Door/Window Sensor, an accessory
intended for use with the RW205 Receiver as part of the PECO Wave Wireless ® System.
The SW206 Sensor (in association with magnet assembly) is designed to report the open/
closed status change of the monitored door/window to the paired PECO RW205 Receiver
(HVAC operation controller) via a built-in radio communication module. The SW206 Sensor
is powered by two AAA alkaline batteries.
DESCRIPTION
The SW206 Wireless Door/Window Sensor operates in association with a required magnet.
When the sensor moves away (min. 10”) from the magnet, the switch opens; when the
sensor moves close to the magnet, the switch closes. A radio signal is transmitted from the
sensor to the associated RW205 Receiver when it detects any door/window open/closed
status change. The sensor is comprised of:
• Front cover: Plastic part must be assembled with unit base for proper sensor operation.
• Printed Circuit Board Assembly (PCBA): Main board for sensor operation and settings.
• Unit base: Plastic base part where the PCBA is located.
• Magnet assembly: Associated magnet must be located within 3/4” (2 cm) of sensor for
proper “closed” signal.
Figure 1. SW206 Door/Window Sensor.
Magnet
assembly
Front Cover Sensor PCBA
▲
Mounting
1. Open the front cover of the SW206 Sensor.
2. Insert two AAA batteries (if not already inserted) in the SW206 battery compartment.
3. Insert screws through the mounting holes of the unit base on the frame of the door/window
(see Fig. 2/3) that will be monitored, and mount the SW206 Sensor.
4. Mount the magnet assembly on the door/window, directly adjacent to the SW206 Sensor.
Note: Magnet assembly must be located within 3/4” (2 cm) of the sensor when the door/
window is in the closed position (see Fig.2/3) for sensor to function properly.
Figure 2. SW206 Sensor Door Mount.
Figure 3. SW206 Sensor Window Mount.
SW206 Sensor
SW206 Sensor
Magnet assembly
Magnet assembly
Unit base
mounting hole
LED
NOTE: In the event of battery depletion, the sensor’s corresponding LED
on RW205 will shut off; the RW205 will assume that the room is occupied.
Radio
module
Pairing switch
Battery
compartment
mounting hole
INSTALLATION
Required Components (included unless noted):
• SW206 Wireless Door/Window Sensor • Two AAA alkaline batteries
• Small Phillips screwdriver (not included)
• Magnet assembly (required)
• Package of screws (4)
LOW BATTERY
The SW206 Sensor LED will blink once every four (4) seconds to alert the occupant
when battery power is getting low. If this occurs, replace old batteries with new batteries
immediately. The LED will stop blinking after new batteries are inserted.
Sensor installation is complete after both wireless pairing and mounting.
STATUS HEARTBEAT
A heartbeat signal will be transmitted from the SW206 Sensor once every 10 minutes to
report the current open/closed status to the associated RW205 Receiver. The sensor will
also transmit an update when the status changes.
FCC COMPLIANCE
This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired
operation.
Warning: Modifications not expressly approved by the manufacturer could void the
user’s authority to operate the equipment under FCC rules.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B
A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communication.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
© COPYRIGHT 2010 PECO, INC. ALL RIGHTS RESERVED.
Indust ry Canada statement :
This device complies with RSS- 210 of the Industry Canada Rules. Operation is
subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
French translation:
IMPORTANT NOTE:( For mobile device use)
Radiat ion Exposure Stat ement :
This equipment complies with IC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
French translation:
PECO Wave Wireless and PECO are registered trademarks of PECO, Inc. The PECO logo is a trademark or servicemark of PECO, Inc.
P/N 70514 3220-2280 REV 00

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Copy, Extract, Print high-res
XMP Toolkit                     : 3.1-701
Format                          : application/pdf
Title                           : P1
Creator Tool                    : Adobe Illustrator CS2
Create Date                     : 2010:12:23 10:19:41+09:00
Metadata Date                   : 2011:01:13 16:36:30+08:00
Modify Date                     : 2011:01:13 16:36:30+08:00
Thumbnail Width                 : 256
Thumbnail Height                : 168
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 8213 bytes, use -b option to extract)
Document ID                     : uuid:F9C2790E3B0EE011BF7FAD96ADB68463
Instance ID                     : uuid:42102eb2-7cf5-4ab1-adeb-9c3db7e7734b
Derived From Instance ID        : uuid:F8C2790E3B0EE011BF7FAD96ADB68463
Derived From Document ID        : uuid:524E6D012008E011B3ABA22984A026E9
Producer                        : PDF-XChange Viewer [Version: 2.0 (Build 54.0) (Jul 12 2010; 13:12:40)]
Page Count                      : 1
Creator                         : Adobe Illustrator CS2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XDTSW206

Navigation menu