Palmer Environmental PERMALOGII Permalog Logger II User Manual Seiten

Palmer Environmental Ltd Permalog Logger II Seiten

User Manual

Download: Palmer Environmental PERMALOGII Permalog Logger II User Manual Seiten
Mirror Download [FCC.gov]Palmer Environmental PERMALOGII Permalog Logger II User Manual Seiten
Document ID146698
Application IDH0e9XZn1LxEdN+GJNgEgDQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize80.55kB (1006928 bits)
Date Submitted2001-04-26 00:00:00
Date Available2001-04-26 00:00:00
Creation Date2001-04-23 15:37:01
Producing SoftwareAcrobat PDFWriter 4.0 für Windows
Document Lastmod2001-04-24 08:43:09
Document TitleSeiten)
Document CreatorGedruckt wird 23135941.tif (21 Seiten)
Document Author: tr

FCC ID: MJCPERMALOGII
Permalog®
Patroller
User’s Guide
environmental
Palmer Environmental
Ty Coch House
Llantamam Park Way
Cwmbran
NP44 3AW
United Kingdom
Tel: +44 (0) 1633 489479
Fax: +44 (0) 1633 877857
Email: info@@lmer.oo.uk
Web: www.pa|mer.co.uk
Pennalog“ Patroller Users Guide
PPUG Issue 6 8/00
Contents
Scope ................
Introduction
Safety warning
Patroller equipment supplied ..
Battery installation
Checking Battery voltage
Connections and interfaces to the Patrolier.
Operating the Patroller.
On-Screen Menus .
Specifications ....
Conditions of Use of Permalog System i.
Pen'nalog® deployment instructions
Warranty ..............................
OWQUIUIPMWW
Pam-ialogo Patroller User's Guide
Scope
This manual covers the uses of the Permalogcm Patroller' in conjunction with
Permalog® 1 and Permalog® 2 leak noise loggers.
Introduction
Permalog® leak nolse loggers are deployed throughout the water distribution
system to provide continuous surveying of leakage. Each Perrnaloga unit
adapts itself automatically to its environment. If no leak is present a signal is
transmitted to indicate normal background conditions (® 0 LEAK). However,
as soon as a possible leak is detected the Pem'ialog unit enters an alarm
state and transmits a signal to indicate a LEAK condition.
Petrol/er used to survey an area
Following a rise in unaccounted-for water,
or at standard intervals, 3 leakage patrol is
can-led out in the area using the Permalcg‘o
Patroller module. This module receives,
analyses and “homes in" on signals to
identify the location of units in LEAK mode
and thereby the approximate position of
the leaks. Information from the loggers is displayed on the LCD screen and
held in memory. Data from loggers" in LEAK mode can be downloaded to a
PC or printed out directly. The Permalog® Patroller may optionally be
integrated with GPS or GIS data to enhance the LEAK list with geographical
or system specific information.
Safety warning
The Perrnalog" noise logger contains a high strength magnet and should not
be can'ied by anyone with a heart pacemaker. This magnet can permanently
corrupt magnetic storage media such as floppy discs, hard discs, tapes etc. It
can also damage TV and PC monitor screens and some watches. See
“Conditions of use".
Caution.
The Patroller contains a lithium backup battery. There is a danger of
explosion if this battery is incorrectly replaced. It must only be replaced with
the same or equivalent type recommended by the manufacturer. Used
batteries must be disposed of according to the manufacturers instructions.
Wamlng
When charging from a 12V vehicle supply. ifthe engine is switched off, the
unit must be disconnected before restarting the vehicle; otherwlse permanent
damage to the charge circuits may result. Once the engine is running, it safe
to re-connect the Patroller.
Patroller equipment supplied
The Patroller is supplied with cables and accessories required for normal
operation.
Patrol/er with magmounr antenna with Patrol/er. carry strap and short
integral lead, cany strap and vehicle antenna (used for surveying on foot).
power supply/charge lead.
The following equipment is supplied as standard:
Patroller unit fitted with rechargeable battery pack
12V Dc power cable with vehicle lighter interface
PC download cable
Carry strap
Small antenna for portable use
Mag-mount antenna with integral coaxial lead
Mains-powered charger unit
_l_l_l_l_\_\_h
The following equipment is not supplied as standard but may be supplied as
accessories to the Patroller:-
Carry satchel
Replacement battery set
Portable printer with cable
Right-angled connector for antenna
Transit case
Battery installation
The Patroller is powered by a rechargeable battery pack located in the back of
the unit. To install the battery pack, use a screwdriver to undo the two panel
7 screws a quarter tum.
Remove the panel. insert the battery pack and clip the battery and Patroller
~ connectors together. Ensure the leads do not become trapped when
replacing the panel. Refit the panel and tighten the screws.
7 WARNING: DO NOT ALLOW ANY METAL OBJECT TO CONNECT THE
TWO BATTERY TERMINALS ON THE CONNECTOR. This would cause a
short circuit and would rapidly generate intense heat in these special
' batteries.
Battery panel cover Serial Number
4— OnlOfl button
Rechargeable
battery pack
7 Back ofPatroIler unit
Checking Battery voltage
To check battery voltage, switch on the Patroller. then press ESC to access
g the main menu. Select Setup, then System info to display battery voltage.
Nominal battery voltage is 7.2V. When the battery voltage drops to 6.5V the
Patroller vvlll start to Issue low battery wamlngs. When the voltage drops to
, 6.0V the unit will power off automatically and can not be used until the battery
is recharged, or an external power supply is connected. Even when the
Patroller is powered off, the data is preserved.
In the event of a battery failure. the data stored in the Patroller is maintained
by a small backup battery for up to one year.
Connections and interfaces to the Patmller
The various connections and interfaces of the Patroller unit are identified on
the diagram below:-
9 Way connector for
GPS communications
BNC connection to
antenna
Carry strap lug
Communirations
connector to PC or
printer
Power suppty and
charger wnneotion
v Ilgming
button tor
Patmller unit: connections and Interfaces
Connections for in-vehicle use
Place the mag-mount antenna on the roof of the vehicle and connect the
antenna lead to the connector on top of the Patroller. Connect the external
power lead to the Patroller and plug into the cigar lighter socket of the vehicle.
Connections for hand-held use
Connect the short antenna to the top of the Patroller. Clip on the carry strap.
Connection to a Printer (optional)
The Patroller uses plain text printing and requires a printer that will support
this. Most dot matrix inkjet and laser printers will, but Windows Printing
System (WPS) printers will not. Check the printer specifications to see that it
supports printing from MS—DOS.
Connect the printer lead to the Communications port. The lead supplied is
terminated with a 9 pin serial connector suitable for most printers with a serial
port. For printers with a parallel port, a serial-to-parallel converter is available.
Connection to a PC (optional)
Connect the PC lead to the Patroller Communications port. and then to one of
the 9-way COM ports on the PC.
Operating the Patroller
The Patroller uses on-screen menus for most of its operational functions. The
key required for each function is highlighted on the display in inverse video.
ESC can be used to exit a function and return to the menu above, Pressing
ESC several times will always return you to the Main Menu.
Press the on-off button to switch the Patroller on. The unit will display the
Palmer logo and firmware version number for 5 seconds then switch
automatically to Leak Patrol mode. During the 5 second period, pressing ENT
takes you directly to Leak Patrol mode and pressing any other key takes you
to the Main Menu.
The backlight for the display will remain on when switched on if the Patroller is
connected to a DC supply. When powered by the Patroller only, the backlight
will switch off after 10 seconds to conserve power.
Front view of
Patroller
High, Medium and Low
sensitivity ranges
On-Screen Menus
Patroller Main Menu
Leak Patrol
Patrol Menu
Deployment
Communications
Setup
This allows access to each of the Patroller‘s modes of operation. These are
as follows:-
1. Leak Patrol
This is the normal mode of operation in the field where data received from
Permalog” loggers is displayed on the screen. The Patrol Menu is normally
accessed directly from Leak Patrol and offers a range of special functions
whilst a patrol is in progress.
Leak Patrol Radio sensitivity
' range
Serial Lv Sp km“ or
08990980 54 6 High
08990127 44 22
08994513 52 1 Details of loggers
indicating leak
08970655 46 14
03984502 40 23
05816442 44 21
03991720 40 6
Deployment
information for
highlighted logger
(if entered)
Leak Scrolling cursor
NoLk ‘|_T_l_ and LEAK/N0
LEAK signals
received.
Leak Patrol Display
The display shows :-
The serial number of loggers in leak mode
The noise level in dB from the logger: Lv
The noise spread in dB from the logger Sp
The time or date the data was received from the logger. The
time is shown for data received today. If the data was received
on a previous day AND more than 12 hours ago, then the date is
displayed.
a The characters on the right hand side of the display are L for
leak and W for warning. Statistically, the probability of a leak
being present is greater for L than for W. However, all logger
results require further investigation to confirm a leak.
All patrol activities are carried out from this screen. The Patroller is fitted with
two sounders. A high pitched beep indicates no-leak and a low-pitched beep
indicates a leak. This information is also shown graphically on the lower part
of the screen where a cursor scans across the screen over a period of 5
seconds. A vertical bar marks each Ieaklno—Ieak event received. with the
height of the bar indicating the received signal strength. When full radio data
is received (serial number, noise level and spread), the bar is marked with a
pennant.
The main part of the screen shows a list of loggers whose full radio data have
been received. One of these is highlighted with an inverting cursor and the
deployment details of the highlighted logger (it entered previously) are shown
in the box below. Use the up and down arrows to move the cursor and select
a different logger.
The number keys each have a specific function assigned. These functions
can be accessed directly by pressing the key in the Leak Patrol screen, or by
first pressing ENT to show the Patrol Menu which lists these functions. The
ENT key toggles between the Leak Patrol Screen and the Patrol Menu
screen.
10
2. Patrol menu
Patrol Menu
Max Range
Mld Range
Min Range
Logger Details
Closest Loggers
Patrol Setup
Clear Display
Restore Display
Print Results
Reset Logger Entry
Ent Leak Patrol
Esc Main Menu
1. nghIMax range
Sets high sensitivity on the radio receiver to achieve maximum range,
typically greater than 50 m.
2. Medium range
Sets medium sensitivity on the radio receiver for a range of typically 15 m.
In an area where many loggers are in range, this can be used to limit the
number of received signals.
3. Low/Minimum range
Sets low sensitivity on the radio receiver for a typical range of 5 m. This
may be used to ‘home-in’ on one particular logger.
4. Logger Details
Press 4, then enter a serial number and press Ent to view the stored
results for a given logger. The default serial number is the currently
highlighted logger. The display shows the level, spread and date received
of the last 6 results, along with the deployment details. Press Esc to return
to the Patrol menu.
5. Closest Loggers
To find the closest loggers to a particular logger, first select the Leak
Patrol screen and check the appropriate logger is selected. Alternatively,
select the Patrol menu and press 4 to enter logger details. Type in the
serial number of the logger you are interested in and press Ent to search
for it. The selected logger details are displayed. Press Esc to return to
the Patrol Menu. Press 5
11
The screen then shows the grid reference of the selected logger by
default. You may either use this grid reference or enter a different one.
Press Ent to search for the closest loggers. The display then shows a list
of loggers within 1000 m of this point. The list of loggers shows serial
number, distanoe from the reference point (in metres), noise level and
time/date last received. From this list of loggers, the up and down arrows
can be used to move a highlight bar. Press ENT to view logger details and
history for the highlighted logger. (This feature will only work if the correct
grid reference has been entered for each logger). Press Eso to return to
this llst.
6. Patrol Setup
Press 6 to go to the Patrol Setup screen. Use the left/right arrows to
change the sounder options, allowing sound for both leak and no-Ieak,
leak only, or neither (sound disabled). Press Ent to return.
7. Clear Display
This option removes the highlighted logger and those below it from the
display (but not from the database) in order to keep only the most recent
acquisitions.
8. Restore dlsplay
Undoes the effect of Clear Display and restores all loggers to the display.
9. Print Results
Sends the Leak Patrol results to a connected printer. There are 4 options
to limit the number of loggers printed.
a. Display only — prints only those loggers in the display list.
b. Today — prints only results received today.
C. Date Range — pn‘nts only results received between the two dates
specified.
d. All Loggers — prints results from all loggers in the database.
0. Reset Logger Entry
When a leak has been repaired and the logger switches back to no—Ieak
mode (this happens automatically), it stops transmitting its serial number
information. This option is used to inform the Patroller that a particular
logger is no longer indicating leak mode. Press ESC to return to the main
menu.
NOTE: When no external power supply is connected, returning to the main
menu will switch off the radio receiver to conserve battery power.
12
3. Deployment
Deployment
Serial 03997244
G.Ref SK 4321 6542
Area DMA 1625
Comment OUTSIDE 27 PARK AVE
Ent Accept
Esc Cancel
This is used when deploying Permalog® loggers on the network. It allows the
location details of each logger to be entered and stored in the internal
database. It also allows logger details to be edited or deleted from the
database.
Enter the logger serial number. Press Ent.
If the same serial number is re-entered, then a Deployment Error Screen is
displayed. You can either delete the entry or confirm it.
Enter the Grid reference of this logger. The first two characters must be
Ietters'. These are followed by numbers for the rest of the grid reference.
Press Ent.
Then enter the area details, up to 8 numbers or characters".
Two seconds alter entering a number, the cursorjumps along one digit.
Altematively you can use the left/right arrow keys.
" To enter letters instead of numbers, press the relevant keypad button
twice or more as required. The numbers and letters step through in sequence
and return to the start point again. For the area details the first character to
appear is always a number. In the Comments section, this is reversed so that
letters come up first.
The system works as shown in this example:-
Press button 2. The number 2 appears.
Press button 2 again. The IetterA appears.
Press button 2 again. The letter B appears.
Press button 2 again. The letter C appears.
Press button 2 again. The number 2 reappears.
To enter a space, press 0 (zero) twice.
13
4. Communications
This menu enables the Patroller to download the logger database to a PC or
to upload the database from a PC. The screen will show the number of
packets of data transmitted and the number of retries attempted if data
transmission was not completed.
5. Setup
This configures the Patroller for the area of operation.
Setup menu
Set date & time
LCD Contrast
Power Saving
Map Refs
Language
System Info
check database
Delete database
Ese Return
1. Set date a. tlme
Set date and time including daylight saving time option.
2. LCD Contrast
Adjust display contrast as required
3. Power Saving
Adjust the time to automatically power off the display back-light when
not used.
4. Map Refs
Select map reference system required.
5. Language
The default language is UK English.
14
System Info
This gives battery smtus information, the firmware version, the number
of loggers on the database and the archive status. if the screen
displays a message saying “Archive out of date”, this means
data has been received from loggers since the database was
transmitted to a PC. In other words, changes have been made that
have not been saved to a PC.
Check database
This option checks the database is intact and will state if it has been
corrupted or not.
Delete database
This option should be used when the Patroller is about to be used in a
different area and the latest version of the existing database has
already been downloaded to a PC. This enables the user to make a
fresh start, knowing that all logger date entered is relevant to the latest
survey
15
Specifications
Pormalog" leak noise logger smciflcatlon
Scope of supply
Logger unit with integral sensor, magnet and aerial (minimum quantity 10
units)
Dimensions
Pemalog 1 193mm x 60mm diameter (without antenna)
Permalog 2 From bottom of magnet to top of logger 110mm
From bottom of magnet to top of antenna 135mm
Diameter 60mm
Antenna length
Pemalog 1 70mm (standard) or 140mm (option for increased range)
Permalog 2 55mm
Weight (Permalog 1 and 2)
1kg
Power source (Pennalog 1 and 2)
Internal battery - up to 10 years” operation (guaranteed 5 years)
Construction materials
(Permalog 1) Hostaforrn 02521 black case, Stainless steel sensor assembly
(Permalog 2) Hostaform 09021 black case , Stainless steel sensor assembly
Environmental Protection (Permalog 1 and 2)
IP68
Communications (Permalog 1 and 2)
Signal LEAK/N0 LEAK
Wsible LED indicator
16
Patrol Ier Smclflcgtion
Scope of supply
Patmller unit including 12V DC power cable with vehicle lighter socket
connector, magnetic vehicle-mounted antenna and cable, short antenna, PC
download cable and printer cable.
Dimensions
290mm x 150mm x 82mm
Weight
1.Bkg
Construction material
ABS
Environmental protection
IP65
Standard antenna
Magnetically-attached vehicle mounting antenna with 3 metre connection
cable
User interface
Membrane keypad with backlit LCD
Power source
Rechargeable/replaceable battery
12V DC vehicle battery power
Communications
Audible LEAK and N0 LEAK signals
R8232 serial output to PC, printer
Antenna input
(optional) GPS receiver interface
Fuse information
Surface mount fuse part no. FUS4040 1.0 Amp, 125 V (F)
Standard accessories
12V DC power cable with vehicle lighter interface
PC download cable
Carry strap
Small antenna for portable use
Optional accessories
Carry satchel
Mains—powered charger unit
Replacement battery set
Portable printer
17
Conditions of Use of Permalog° System
1. Deployment of F‘ermalog'm units should be carried out in accordance with
Palmer Environmental document PDI(E) Issue 1. Mishandling the logger
could result in damage to the antenna (if incorrectly used to lower or raise
the logger) or the sensor (connecting the logger to, or removing it from, the
fitting). Such damage is not covered by Palmer Environmental’s 5-year
warranty and customers are warned that damage to the sensor in
particular is unlikely to be economic to repair.
2. During handling and transportation of Permalog" units from place to place,
care must be taken not to bring the communications window into the
magnetic field of a medium or strong strength magnet. Continuous
exposure to a magnetic field can result in variation in the Permalogo‘s
internal clock, which will lead to an increased possibility of false alarms.
Particular care must be taken to avoid packing Pen’nalog® units “head to
tail". Remedial work by Palmer Environmental required to correct loggers
that have been affected in this way is not covered by warranty and will be
charged.
3. Due to the strength of the magnet used with Pennalog®, large quantities of
Permalog‘g units should not be carried by staff with heart pacemakers.
4. The magnet keeper fitted to Permalog loggers should be left attached to
the magnet until the unit is ready to be placed in its logging position. If the
unit is to be moved for any reason the keeper should be refitted to the
magnet. All Permalgg units should be transmrted with the keegr
attached to the magnet.
18
Pormulog Deployment Instruction
1. Ensure that both the screw thread on the Fennalog Is a permanenfly installed
aerial and the screw hole on top of the Permalng are leak noise monltorr‘rrg unit.
Clea" it transmits a short 1mW radio
signal at 173MHz every 5 seconds.
. Screw the mental into the top of the Pemrelog
firm e! by hand Ensure that the mbberwoeher Is
to make a watertight seal (Fig 1).
3. Reset the Permelog by passing a mgnet
close to and across, the communications window.
(Fig 2) Look into the communications window to see
a faint red LED flash every 5 eeoonds. if the LED
does not flash, then pass the magnet across the
window again and look into the window to verify.
Resetti the Ferrrralog erases the internal memory.
Should rbe moved liom one location to
another, If mu be reset in remove historical data
Thisisthaonlywa toresettheunlt-itcannotbe
switched off even f a magnet ls passed over it many
fimes. Once reset, it will ousrets continuous forthe
life of the batteries. The guaranteed batteryl
years, Any medium strength magnet will reset the
Pennalog; for convenience, the magnet on another
Permalog may be used (Fig 2).
Do not attempt to remove the magnet from the
bottom ofeny Permelog - It Is lootited on and should
not be removed.
4 Attach the Permaiog to a metal pipe fitting
using the magnet on the base. Always ensure that
the Contact point is free from dirt so that the magnet
makee a good contact
5. The Permalog must remain In an up htl
vertical position when mstalled. The serial is exible
and may be bent out of the way to retita manhole
cover.
Only eerie/s supplied b Palmer Environmental may
be used. Pemralog u ts have no user serviceable
parts. If any unit does not appear to function
con-ectly then it muetbe returned to Fell-her
Environmental oren authorised Palmer
represenlatlve.
Pennalog units have no userservr’oeable parts. The enclosure protects the user from electrical shock
and other hazards, Sen/icing must be refined to corruaetent personnel If any unit does not appear to
hmctlon correctly then it mustbe returned to Palmer Environmental oren authon'sed Palmer
represenhtlve. Caution: Penna/cg units contain batteries, There Is a dangerofexploslon if they are
inconectly replaced. They must only be replaced with me same orequivalent type recommended bythe
manufacturer Used batteries must be disposed ufacoordlng to the manufacturers instrudlone.
Biogloyment
- Ensure you have sutfiotent keepers for the magnets and pieces of card to out between the
keepers end the logger magnets. Removing keepers from logger magnets takes some eltort.
Always insert a pleoe ofthln card between the keeper and the magnet to make this Job easier.
On retrieval, airways grasp the main body of the logger. Do not pull loggers by the serials.
Ensure the magnet lmm one logger is kept more than 3 Indies (Borne) away item the window
01 the nearest logger. If any magnet is held too close to the logger window. the logger will
oontinuelty reset causing an lnooneot Internal clock setting.
. An option during transport is to magnetically attach the loggers to a large piece of metal. This
will act as a keeper and prevent the loggers from moving.
19
Permalo 2De Io mentlnstruc n
1. Ensure that both the screw thread on the aerial
and the lower recessed screw hole in the Permalog are
clean. then screw the aerial into the lower screw hole
firmly by hand. Ensure that the rubber washer is fitted to
make a watertight seal (Flg 1). Remove the magnet
keeper and store for later use.
2. Reset the Pen-naiog by passing a magnet close to,
and across. the communications window. (Flg 2). Look
Into the oommunlcatlons wlnoow to see a faint red LED
flash every 5 seconds. it the LED does not flash, then
pass the magnet across the window agaln and look into
the window to verify.
Resetting the Permalog erases the internal memory.
Should the logger be moved from one location to another,
it must be reset to remove historical data.
This is the only way to reset the unit - it cannot be
swltched off even if a magnet is passed over it many
times, Once reset, it will operate continuously for the life
of the batteries. The guaranteed battery life is 5 years.
Any medium strength magnet will reset the Permalog; for
convenience, the magnet on another Pennelog may be
used (Fig 2).
Do not attempt to remove the magnet from the bottom of
any Perms/cg - it is loctited on and should not be removed.
3. Attach the Permalog to a metal pipe-fitting using
the magnet on the base. Always ensure that the contact
point is free from dirt so that the magnet makes a good
contact. if an eye-hook (optional accessory) is used, this
must be screwed Into the top ofthe logger.
4. For best performance, it is recommended that the
Permalog unit is deployed in a vertical/upright position.
Only use serials supplied by Palmer Environmental. A
right angle connector is available to position the aerial
vertlcally.
Permelog units have no user serviceable parts. Ute
enclosure protects the user from electrical shock and other
hazards. Servicing must be refen'ed to competent
personnel If any unit does not appear to function correctly
then it must be returned to Palmer Environmental or an
authorised Palmer representative.
Caution: Pennalog units contain batteries. There is a
Screw thread for
optional hook
Oommnicetro' ns
'ndow
Flashing LED
danger of explosion it they are incorrectly replaced They must only be replaced with the
same or equivalent type recommended by the manufacturer. Used batteries must be
disposed of awarding to the manufacturers instructions.
Redemoyment
o Ensure you have sufficient keepers for the magnets. Removing keepers from logger
magnets takes some effort Always insert a piece of thin card between the keeper
and the magnet to make this job easier.
- On retrieval, always grasp the main body of the logger. Do not wll Iogggrs by the
serials.
~ Ensure the magnet from one logger is kept more than 3 inches (Boms) away from the
window of the nearest logger. If any magnet is held too close to the logger window.
the logger will continually reset causing an incorrect internal clock setting,
0 An option during transport is to magnetically attach the loggers to a large place of
metal. This will act as a keeper and prevent the loggers from moving.
20
Warranty
7 Permalog” loggers are warrantied 5 years.
Permalog® Patrollers are warrantied 1 year.
All equipment is warrantied by Palmer Environmental Ltd to be free from
defects in materials and workmanship for a period of one year (unless
a othenNise stated) from the date of shipment to the original customer. This
warranty ls only valld If the equipment has been installed and used in the
correct manner as described in this manual.
Repair or replacement (at Palmer Environmental‘s option) will be made
without charge provided the above conditions have been met.
If any problems occur, notify Palmer Environmental Ltd or its authorised
representative giving full details of the problem, and the model and serial
number of the equipment. You will receive technical advice and/or shipping
instructions depending upon the nature of the problem.
Palmer Environmental Ltd
Ty Coch House
Llantamam Park Way
Cwmbran
NP44 SAW
United Kingdom
Tel: m (o) 1533 439419
~ Fax: +44 (0) 1633 811857
email:info@pa|mer.co.uk
Mtp:llwww.palmar.co.uk
21

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Creator                         : Gedruckt wird 23135941.tif (21 Seiten)
Create Date                     : 2001:04:23 15:37:01
Title                           : Seiten)
Author                          : tr
Producer                        : Acrobat PDFWriter 4.0 für Windows
Modify Date                     : 2001:04:24 08:43:09+02:00
Page Count                      : 21
Has XFA                         : No
EXIF Metadata provided by EXIF.tools
FCC ID Filing: MJCPERMALOGII

Navigation menu