Panamax Max A Max4310 Users Manual
MAX4310 to the manual 7c4827c5-0923-4c6f-8b5a-7ff1cba3bb3f
2015-02-06
: Panamax Panamax-Max-A-Max4310-Max4310-Users-Manual-516318 panamax-max-a-max4310-max4310-users-manual-516318 panamax pdf
Open the PDF directly: View PDF .
Page Count: 1
Download | |
Open PDF In Browser | View PDF |
INSTRUCTIONS MAX 4310 ® Thank you for choosing Panamax . The MAX® 4310 is designed to provide maximum protection for audio/video equipment with external signal connections such as cable TV, rooftop antenna and DBS satellite systems. INSTALLING THE MAX ® 4310 NOTE: The MAX® 4310 and the connected equipment must be indoors and in the same building. AC Installation 1. Plug the MAX ® 4310 directly into a properly grounded 3-wire AC outlet*. 2. Turn the MAX® 4310 on. 3. Plug in one of the pieces of equipment you want to protect and turn the equipment on. If the equipment is working correctly, continue to plug in and turn on your equipment. In the extremely unlikely event that everything does not work perfectly, stop and read the troubleshooting section. If you continue to have problems, call PANAMAX Customer Relations Department at 800-472-5555, USA and Canada. *Many old buildings are inadequately wired. It is very common for a building to be improperly grounded. Building wiring and grounding must conform to applicable NEC (USA) or CEC (Canada) codes for the PANA MAX connected equipment policy to be valid. Switched Outlets pushbutton one of two triggers that can turn-on or turn-off the switched outlets. Leave this switch in the ON position if the DC trigger is being used. Note to CATV Installer: This reminder is provided to call the attention to Article 820-40 of the NEC. That article provides specific guidelines for proper grounding. It specifies that the cable ground shall be connected to the grounding system of the building and as close to the point of cable entry as practical. Satellite Coax Installation ** 1. Connect the coax cable from the satellite dish to a Satellite coax terminal on the MAX® 4310. Phone Installation 1. Connect a phone cable from the wall jack to the LINE terminal on the telephone jack on the MAX® 4310. 2. Connect the provided phone line cable from the EQUIP terminal on the MAX® 4310 to the input jack on your satellite receiver. Please note that the protection circuitr y will not work if these lines are reversed. When running the DBS system test, the DBS connection displays as failed. Check the appropriate connections to ensure that they are correctly and securely installed. Rack Mounting An optional rack mount kit is available. Order # GRM2205. If you continue to have trouble with your MAX® 4310 or this section has not fixed the problem, please call PANAMAX Customer Relations Department at 800-472-5555. 2. Connect the provided coax jumper cable to the other Satellite coax terminal on the MAX® 4310. TROUBLESHOOTING 3. Connect the other end of the coax jumper cable to the input jack on your satellite receiver. There is no AC power to my equipment, or my equipment doesn’t turn on. Make sure that the MAX ® 4310 is plugged into a working AC outlet. Check all AC connections. Cable TV or Rooftop Antenna Coax Installation ** 1. Connect the coax cable from the wall or floor plate to a CATV/ANT coax terminal on the MAX® 4310. 2. Connect the provided coax jumper cable to the other CATV/ANT coax terminal on the MAX® 4310. 3. Connect the other end of the coax jumper cable to the input jack on your television, VCR, or satellite receiver. **There is no designated input or output jack for the MAX® 4310 Satelliteand CATV/ANT coax terminals. The coaxial protection circuitry is bi-directional in both signal transmission and protection capabilities. Switched Outlets LED (green) indicates the status of the “Switched Outlets” pushbutton and corresponds with the switch position. Ground OK LED - (green) indicates that the wall outlet is properly grounded. CONTACTING PANAMAX For product and warranty information, dealer information, and other general information contact Customer Relations at: Make sure the MAX ® 4310 and connected equipment is turned on. If you are using the 12VDC trigger, make sure that the source is actually supplying the voltage needed to activate the MAX® 4310. Check to see if the circuit breaker on the MAX® 4310 needs to be reset (press in). Email: Web: Fax: Phone: custrelations@panamax.com www.panamax.com 707-283-5901 800-472-5555 or 707-283-5900, 7:30 a.m.- 5 p.m.PST The MAX ® 4310 circuit breaker disconnects AC power from the connected equipment. You have exceeded the ampere rating for your surge protector. As a temporary fix, disconnect one or more pieces of equipment. Ask your dealer about additional PANAMAX products that may be required. Ground Fault LED - (red) when lit, indicates that the wall outlet is improperly wired. Unsafe Voltage LED - (red) when lit, indicates that incoming voltages are unsafe and the surge protector has disconnected the power to protect your equipment. Always-on Convenience Outlet 10 Ft. AC Power Cord - 15A Circuit Breaker - will automatically “open” when the current load is greater than 15 Amperes. When this happens, the circuit breaker can be manually reset by simply pushing the reset button, which will have “popped” out.” There is no picture or sound on my TV . Check the coaxial connections, making sure that they are correctly and securely installed. Ensure that the TV set is plugged into a powered AC outlet. MAX® 4310 PRODUCT SPECIFICATIONS AC Surge Protection Line Voltage……………......……………….120V, 50/60 Hz Maximum Current Rating…….......................………….15A UL 1449 Surge Suppression Rating…...................……330V Protection Modes…………………….......…..L-N, L-G, N-G Initial Clamping Level………........….200V Peak, 141V RMS Response Time………...........................……………...<1ns Joule Rating……………………............………1650 Joules Peak Impulse Current……...........................………52,000A EMI/RFI Noise Filtration……......…. 50dB (100KHz - 1 MHz) Catastrophic Surge Circuit……......................………….YES Thermal Fusing……...................……………………….YES Over/Under Voltage Protection……....................………YES Over-voltage shutoff threshold…………..............…147V ±8 Under-voltage shutoff threshold……..................……84V±6 DC Trigger Connection………………….............……3.5mm mini-plug Voltage and Polarity……..................5-30VDC, bi-directional Current Requirement….......................……………>10mA Always-On Outlets Three Always-On, Balanced L Filtered outlets provide a constant power source for programmable analog or digital equipment. Switched Outlets Four Balanced L Filtered outlets controlled by one of the two trigger sources. Voltage Sense Trigger Input - 3.5mm Mini-Plug jack. Connect to a remote trigger device that pro vides 12VDC to trigger a startup/ shutdown sequence. This is the second trigger that will turnon or turn-off the switched outlets. Telephone Jacks In/Out connections for telephone line or pay-per-view line protection. Cable TV Coax Jacks Single pair of gold plated F-connectors optimized for Cable TV and Rooftop Antenna signal line protection. Satellite Coax Jacks - Two pair of gold plated F-connectors optimized for Satellite TV signal line protection. Satellite Circuit Clamping Level………...........................……………….27V Attenuation……..................…<1 dB from 950MHz - 2.2GHz Shielded……........................................………………..YES Connections……..........……………Gold plated, Female “F” CATV/ANT Circuit Clamping Level……..................................…………….0.7V Attenuation………….........……<1 dB from 5MHz - 950MHz Shielded……….................................………………….YES Connections…………………......…Gold plated, Female “F” Telephone Circuit Clamping Level…….....................................………….260V Capacitance………………….....................…30pf (approx.) Suppression Modes…….......………Metallic & Longitudinal Wires Protected…………......……….2 wire/ 1pr. (Pins 4,5) Fuseless/Auto-Resetting……..................................……YES Connections…………........................……………RJ-11/45 1690 Corporate Circle, Petaluma, 94954 • Phone 707-283-5900 • Toll Free 800-472-5555 • Fax 707-283-5901 • www.panamax.com INS4310 REV. A 11/02
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 1 Creator : QuarkXPress™ 4.1 Create Date : 2003:02:24 16:07:18 Subject : Title : Author : GEORGEM Producer : Acrobat PDFWriter 4.0 for Power MacintoshEXIF Metadata provided by EXIF.tools