Panasonic Healthcare 9TB095DSS DDS Storage Device User Manual 1U Sfy

Panasonic Healthcare Co., Ltd. DDS Storage Device 1U Sfy

users manual

DDS BACKUP LIBRARYLKM-SD21-S         INSTRUCTION MANUALPlease read through these instructions before operating this unit.
IMPORTANT SAFETY NOTICELMQT00583For USACAUTION :Use shielded connecting cables in order to meet FCC emission limits and also to preventinterference to nearby radio and television reception.FEDERAL COMMUNICATIONS COMMISSION (FCC) RADIOFREQUENCY INTERFERENCE STATEMENTClass B Computing DeviceNOTE : This equipment has been tested and found to comply with the limits for a Class Bdigital device, pursuant to part 15 of the FCC Rules. These limits are designed to providereasonable protection against harmful interference in a residential installation.This equipment generates, uses and can radiate radio frequency energy and , if notinstalled and used in accordance with the instructions, may cause harmful interferenceto radio communications. However, there is no guarantee that interference will not occurin a particular installation. If this equipment does cause harmful interference to radioor television reception, which can be determined by turning the  equipment off and on, theuser is encouraged to try to correct the interference by one or more of the followingmeasures :- - Reorient or relocate the receiving antenna.- - Increase the separation between the equipment and receiver.- - Connect the equipment into an outlet on a circuit different from that to which the     receiver is connected.- - Consult the dealer or an experienced radio/TV technician for help.FCC WARNING : Changes or modifications not expressly approved by the partyresponsible for compliance could void the user’s authority to operate the equipment.NOTICE(1) You may not reproduce or transcribe any part of this publication without permission.(2) We reserve the right to revise this document at any time without notice.(3) If you have any questions about this document, contact your sales representative.SAFETY NOTICE(1) To prevent fire or electric shock, do not expose this appliance to rain or moisture.(2) To avoid electric shock, do not attempt to disassemble the cabinet.(3) For pluggable equipment, the socket-outlet shall be installed near the equipment andshall be easily accessible.
IMPORTANT SAFETY INSTRUCTIONS  1. Read all of these instructions.  2. Save these instructions for later use.  3. Follow all warnings and instructions marked on the product.  4. Unplug this product from the wall outlet before cleaning. Do not use liquid cleanersor aerosol cleaners. Use a damp cloth for cleaning.  5. Do not use this product near water.  6. Do not place this product on an unstable rack, cart, stand, or table. The product mayfall, causing serious damage to the product.  7. This product should be operated from the type of power source indicated on themarking label. If you are not sure of the type of power available, consult yourdealer or local power company.  8. This product is equipped with a 3-wire grounding type plug, a plug having a third(grounding) pin. This plug will only fit into a grounding-type power outlet. This is asafety feature. If you are unable to insert the plug into the outlet, contact yourelectrician to replace your obsolete outlet. Do not defeat the purpose of thegrounding-type plug.  9. Do not allow anything to rest on the power cord. Do not locate this product wherepersons will walk on the cord.10. If an extension cord is used with this product, make sure that the total of theampere ratings on the products plugged into the extension cord do not exceed theextension cord ampere rating. Also, make sure that the total of all productsplugged into the wall outlet does not exceed 15 amperes.11. Never push objects of any kind into this product through cabinet slots as they maytouch dangerous voltage points or short out parts that could result in a risk of fireor electric shock. Never spill liquid of any kind on the product.12. Do not attempt to service this product yourself, as opening or removing covers mayexpose you to dangerous voltage points or other risks. Refer all servicing toservice personnel.13. Unplug this product from the wall outlet and refer servicing to qualified servicepersonnel under the following conditions:A. When the power cord or plug is damaged or frayed.B. If liquid has been spilled into the product.C. If the product has been exposed to rain or water.D. If the product does not operate normally when the operating instructions arefollowed. Adjust only those controls that are covered by the operatinginstructions since improper adjustment of other controls may result in damageand will often require extensive work by a qualified technician to restore theproduct to normal operation.E. If the product has been dropped or the cabinet has been damaged.F. If the product exhibits a distinct change in performance, indicating a need forservice.14. Slots and openings in the cabinet and back or bottom are provided for ventilation andto ensure reliable operation of the product and to protect it from overheating. Theseopenings must not be blocked or covered.
KIT CONTENTS■  DDS Backup Library Unit■  Power Cable■  Safety Instruction ManualRecommended Kits◆ SCSI Interface BoardAdaptec SCSI narrow (AHA-2940 series)◆ Terminator (for SCSI daisy Chain)P/N: ACK-68 TERM KIT (1718100)  ( by Adaptec )◆ RackPlease use the suitable rack for this Library.( should be based on EIA standard )◆ Angle or Rail (Rail-Bracket) for Installing into RackPlease use the suitable angle or rail for the Library and Rack.( should be based on EIA standard )◆ Application Software ( for Writing / Reading )ARCserveNetVault ( by BakBone Software )Backup Exec ( by VERITAS Software Corporation )◆ Cartridge TapeFuji Film ( DDS-4, P/N: DG4-150M )◆ Cleaning TapeFuji Film ( P/N: DDS DG-15CL WS ),  Sony ( P/N: DGD15CL )–––– If Daisy Chain Connection ( for EMC: Electro-Magnetic Compatibility) ––––◆ SCSI interface cableAdaptec ( P/N: ACK / WP-WP )◆ Ferrite-CoreTDK ( P/N: ZCAT2436-1330A-M )This product can be used with the attached power cable only.• SCSI : Small Computer System Interface.•All other product/ brand names are trademarks or registered trademarks of theirrespective companies.    NOTE :
PARTS AND FUNCTIONSFront View➀➁➂➃➄➅➆➇➈➉11 12➀ Rack Mount Plate     For mounting to the rack➁ Air Flow Hole ( for absorption )     Not be blocked or covered to protect this Library from overheating➂ Cartridge Insertion Portion ( Door )     Trough hole for setting/ ejecting cartridge tape to/from the Library➃ LCD Display     Displays the Garage/ Cartridge-tape and the Library operating status,     and Menu mode screen.  This has a backlight function.➄ Power LED     Lights up "Green" when the Library power is ON➅ Testing Connector     Use for repair/ modification ( Not use generally )➆ Drive Status LED     Lights up "Green" while accessing to the drive➇ Tape Status LED     Lights up "Green" while setting a tape in the drive➈ Fault LED     Lights up "Red" when any system error occurred ( For error detail, see the LCD display)➉ Cursor Key Button     Press to select garage or cartridge tape ( Operation mode )     Press to select menu item ( Menu mode ) 11 ESC/DOOR Button     Press to cancel a execution ( escape the interrupted status ), return to the previous     screen ( Menu mode ), or close the front door. 12 ENTER Button     Press to input any data/ text, execute the command item or set the selected item.
MOUNTINGRear View1) If you need the Rail (Rail-Bracket) or Angle for mounting to your rack, attach the suitableones for the Rack / Library to them.– For details of installing the Rail (Rail-Bracket) or Angle, refer to each manual for them.2) Gently slide the Library into the vacant rack part, and secure it with mounting screwsas below figure. Angle Rail-BracketRack Mounting                Screw RailNote :Surely mount to horizontal direction.The above equipments ( Angle/ Rail/ Rail-Bracket/ Screw ) are NOT includedwith this product.➀ Power On/Off Switch➁ Power Connector     Connect the attached power cable➂ Fan / Air Flow Hole ( for release )     Not be blocked or covered to protect this Library from overheating➃ SCSI Interface Connector     Connect the SCSI interface cable ( 68-pin half pitch type )     – If this Library is a terminal device on the SCSI bus, connect the proper terminator        to the other (vacant) connector.➀➁➂➃
CONNECTING4321Please connect the power and SCSI interface cable to the rear of the Library as follows.Before you begin the below connecting steps, make sure that the host PC and thelibrary Power switch is OFF.  ( Recommended the host PC power cable is unplugged )➀Connect the SCSI interface cable to the Library.➁Connect  the other end of SCSI interface cable to the host PC's SCSI connector.➂Connect the attached power cable to the Library and AC outlet.➃Switch the Library power ON.When switch the Library power ON, this Library scans the tape In/Outof all the garages (slots).  Please wait for a moment of the slot tape scanning ( until"READY" is appeared on the LCD ).➄Set up SCSI ID number with key-buttons and LCD display in Menu mode.If the default setting is incorrect for your system, please set up according to the system.( Set up to the vacant ID No. )➅ Turn your host PC power ON.AC OutletHost PC'sSCSI connectorDDS Backup LibraryPower Cable( Attached )SCSI Interface Cable( Not attached )Note:The connecting sockets are keyed.If Daisy Chain ConnectionIf connect other SCSI device to the other SCSI connector on the Library (SCSI daisy Chainconnection), follow the below procedure for EMC (= Electro-Magnetic Compatibility).Please connect the recommended SCSI interface cable mounted the Ferrite-Core to theother SCSI device side as below figure.Less than100 mm lengthLibrary sideOtherdevice sideFerrite-CoreNote :These SCSI interface cable and Ferrite-Core are NOT attached with this product.
SPECIFICATION SUMMARYGENERAL PERFORMANCE➀   Power rating 120 – 240 V ~ AUTO0.5 – 0.28 A      50 / 60 Hz➁   Dimensions (W x H x D) 430 x 44 x 650 mm➂   Weight 11.5 kg [ typical ]➃   Temperature     Operating:   5~40 °C Non-operating:  – 40~65 °C➄   Humidity                        Operating:   20~80 %RH Non-operating:   0~90 %RH    (Max. wet bulb temp. is 26 °C, Non-condensation) (Non-condensation,No cartridge tape)ENVIRONMENTAL CONDITIONSWeight and dimensions shown are approximate.Specifications are subject to change without notice.LMQT00583 Printed in Japan

Navigation menu