Fire alarm system EBL512 1548, 1549 and 1550 • • EBL512 -- an intelligent analog addressable fire alarm system Up to 512 addresses per control and indicating equipment (c.i.e.) • TLON network for up to 30 c.i.e.:s Analog addressable system Up to 512 addresses EBL512 is an intelligent analog addressable fire alarm system, conforming to the EN54-2 and –4 standards. EBL512 has the capacity of connecting 512 addresses. Basic configurations 128, 256 or 512 addresses. Can be upgraded on site. Each c.i.e. has four COM loops for connection of up to 512 loop units. Each addressable loop unit uses one address. Some loop units that can be connected: • Analog detectors (sensors) • Addressable manual call points • Addressable short circuit isolators • Addressable input and output units • Addressable sirens & sounder bases • Addressable external power supply units • Conventional detectors and manual call points Features / functions The fire alarm system EBL512 meets the most stringent requirements relating to fire detection and alarm. A user-friendly PC software Win512 is used for site specific data editing, download, backup and SW download. Some features / functions: • Adaptation of each analog detector's alarm level in relation to its contamination. Service signal when required. • Algorithms for filtering and alarm, to reduce nuisance alarms. Algorithm for faster detection of smouldering fires. • Functions, customer related: Test mode, alert annunciation, disablements, etc. • Functions: Fire door closing, interlocking combinations of outputs & inputs, time channels, alarm delay, twounit dependence, user definable text message for each alarm point, etc. • Programmable inputs and outputs and a large number of trigger conditions. • Expansion boards (options) with zone line inputs or relay outputs. • Interface (option) for ext. Fire brigade panels, alert annunciation units, data converters, etc. TLON Network Up to 30 EBL512 c.i.e.:s can be connected to a TLON network. A TLON connection board 1590 is then required in each c.i.e. Miscellaneous EBL512 has space in the cabinet for two sealed Lead Acid 24 (27) Ah batteries. In each c.i.e. can be mounted up to six expansion boards 1580-1587. The ext. FBPs 182x and the Alert Annunciation units 173x, shall be connected via a 1587 board. One Web-server II 1598 (option) connects the EBL512 system to Internet / an Intranet (LAN). Panasonic Electric Works Fire & Security Technology Europe AB Citadellsvägen 23, SE-211 18 Malmö, Sweden Tel: +46 (0)40 697 70 00 • Fax: +46 (0)40 697 70 99 info-fste@eu.pewg.panasonic.com • www.panasonic-fire-security.com Type numbers 1548 1549 1550 EBL512 c.i.e., excl. printer, configured for 128, 256 or 512 addresses. EBL512 c.i.e., incl. printer, configured for 128, 256 or 512 addresses. EBL512 c.i.e., excl. front panel, excl. printer, configured for 128, 256 or 512 addresses. Printer board (option for 1548). Cabinet for drawings. 8 zones expansion board (8 zone line inputs for conventional detectors). 8 relays expansion board (8 programmable relay outputs). External FBP interface board (for connection of data converters and the "older" types of ext. FBPs). German FBP interface board (for connection of a "Feuerwehr-Bedienfeld", incl. a VdS Standardschnittstelle "Löschen"). Autronica interface board (for connection of Autronica, BS100 units). Connection cable (male-male) for the 1580-1587 boards (no. 1->2 and no. 5->6). Connection cable (female-female) for the 1580-1587 boards (no. 3->4). External FBP / DU interface board (for connection of the newest types of display units, e.g. ext. FBPs (1826 / 1828) and Alert Annunciation units (1735 /1736). TLON connection board (for TLON network). One board in each c.i.e. 1558 1572 1580 1581 1582 1583 1584 1585 1586 1587 1590 Technical data Voltage primary (V AC) secondary system (V DC) Current consumption (mA) Ambient temperature (°C) operating storage 230 24 Depending on type (1548-1550), expansion board(s), etc. See EBL512 Planning Instructions. 0 to +40 -40 to +70 Ambient humidity (% RH) max. 90, non-condensing Ingress Protection rating (estimated) IP32 Inputs 4 COM loops for 128, 256 or 512 addresses 4 programmable Outputs 4 programmable supervised voltage outputs 2 programmable relay outputs Relay outputs for routing equipment (Fire brigade tx and Fault tx) Power supply (24 V DC) for routing equipment and external equipment Size W x H x D (mm) 400 x 610 x 175 Weight (kg) 1548: 17.6 / 1549: 18 / 1550: 17.4 Colour (metal cabinet) Light grey (NCS S1500-N, PMS Cool Grey 2) Approvals CE; Conforms with EN54-2 and -4. The front conforms with SS3654. Note! All voltages are nominal. All technical features and data are subject to changes without notice, resulting from continuous development and improvement. Product Leaflet Date of issue Revision / Date of revision MEW00006 2000-05-12 6 / 2008-01-24
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Count : 2 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:a9e50b72-cb56-447d-809a-5ca08de24818 Producer : Acrobat Distiller 6.0.1 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2008:01:24 09:31:10+01:00 Create Date : 2008:01:24 09:31:10+01:00 Document ID : uuid:cd2d8df2-e13e-4309-9e0d-ac3aa9ea95ba Format : application/pdf Title : Microsoft Word - MEW00006rev6.doc Creator : PetterssonJ Author : PetterssonJEXIF Metadata provided by EXIF.tools