Panasonic Fv 05 11Vkl1 Installation Manual 11VKSL1 (English)
Panasonic-Fv-05-11Vk1-Installation-Manual-731091 panasonic-fv-05-11vk1-installation-manual-731091
fv0511vkl1 de35aeed-ea3a-44b6-bbd0-60d609ec6955 Panasonic Oxygen Equipment FV-05-11VKL1 User Guide |
2015-05-18
: Panasonic Panasonic-Fv-05-11Vkl1-Installation-Manual-731114 panasonic-fv-05-11vkl1-installation-manual-731114 panasonic pdf
Open the PDF directly: View PDF
.
Page Count: 12
| Download | |
| Open PDF In Browser | View PDF |
INSTALLATION INSTRUCTIONS Ventilating Fan Model No. Representative models: FV-05-11VKSL1 FV-05-11VKL1 FV-05-11VKSL1 FV-05-11VKL1 FV-11-15VKL1 Contents GENERAL SAFETY INFORMATION 2-3 PLEASE READ PRIOR TO INSTALLING THIS FAN 3-4 DESCRIPTION 4 UNPACKING 4 SUPPLIED ACCESSORIES 5 DIMENSIONS 5 WIRING DIAGRAM 5 FEATURE 6 INDICATION (PLUG ‘N PLAY FUNCTION DEVICES) MOTION (PLUG ‘N PLAY FUNCTION DEVICES) 7 INSTALLATION (PLUG ‘N PLAY FUNCTION DEVICES) 8 INSTALLATION (NEW CONSTRUCTION) FV-11-15VKL1 6-7 8-10 INSTALLATION (RETROFIT) 10 MAINTENANCE (CLEANING) 11 MAINTENANCE (REPLACEMENT OF LAMP) 11 PRACTICAL GUIDE TO INSTALLATION BACK COVER SPECIFICATIONS BACK COVER PRODUCT SERVICE BACK COVER READ AND SAVE THESE INSTRUCTIONS Thank you for purchasing this Panasonic product. Please read these instructions carefully before attempting to install, operate or service the Panasonic product. Failure to comply with instructions could result in personal injury or property damage. Please explain to users how to operate and maintain the product after installation, and this booklet should be presented to users. Please retain this booklet for future reference. GENERAL SAFETY INFORMATION For Your Safety To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or property, always observe the following safety precautions. Explanation of symbol word panels The following symbol word panels are used to classify and describe the level of hazard, injury, and property damage caused when the denotation is disregarded and improper use is performed. WARNING Denotes a potential hazard that could result in serious injury or death. CAUTION Denotes a hazard that could result in minor injury. The following symbols are used to classify and describe the type of instructions to be observed. This symbol is used to alert users to a specific operating procedure that must be followed in order to operate the unit safely. This symbol is used to alert users to a specific operating procedure that must not be performed. This symbol is used to alert users not to disassemble the equipment. This symbol is used to alert users to make sure of grounding when using the equipment with the grounding terminal. WARNING To reduce the risk of fire, electric shock or injury to persons, observe the following : Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. Ducted fans must always be vented to the outdoors. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI(Ground Fault Circuit Interrupter) - protected branch circuit. These models are UL listed for tub and shower enclosures. Canada only: Not to be installed in a ceiling thermally insulated to a value greater than R40. Do not disassemble the unit for reconstruction. 2 GENERAL SAFETY INFORMATION CONTINUED WARNING When this product is no longer being operated, please remove the product to prevent the possibility of falling. Ceiling joist must be subjected to static load more than five times the weight of the product. Do not install with a method which is not approved in the instructions. Do not use this fan with any solid-state speed control device. Solid state controls may cause harmonic distortion which can cause motor humming noise. This product must be properly grounded. CAUTION Do not install this ventilating fan where interior room temperature may exceed 104°F(40°C). Prohibited Make sure that the electric service supply voltage is AC 120V, 60Hz. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA). Prohibited Always disconnect the power source before working on or near the fan, motor, light fixture or junction box. Protect the supply wiring from sharp edges, oil, grease, hot surfaces, chemicals or other objects. Prohibited Adaptor Do not kink the supply wiring. Prohibited Provide make up air for proper ventilation. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. Do not install the unit where ducts are configured as shown in Fig.A. (Cooking area) Do not install above or inside this area 45 45 Not for use in cooking area. (Fig.B) The special-purpose or dedicated parts, such as mounting fixtures, must be used if such parts are provided. Cooking equipment Floor Fig. B PLEASE READ PRIOR TO INSTALLING THIS FAN Spot and Continuous Ventilation: These fans are designed to run continuously ensuring a healthy environment at low CFM levels 24 hours a day. By utilizing the optional CustomVent Multi-Speed module the fans are built to run continuously at a pre-set lower level (FV-05-11VKSL1 and FV-05-11VKL1: 0, 30, 40, 50, 60, 70, 80, 90, 100 CFM; FV-11-15VKL1: 0, 50, 60, 70, 80, 90, 100, 110, 120 CFM). The setting is dependent on the size of the house and the individual wishes of the homeowner. It is crucial that the installer pre-set the lower setting during the installation. Please refer to the chart below and the switch indication on page 6. 3 PLEASE READ PRIOR TO INSTALLING THIS FAN CONTINUED CustomVent Multi-Speed module (Lower Setting). ASHRAE 62.2-2010 (sq.feet) Two Bedrooms Three Bedrooms Four Bedrooms <1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000 5,500 6,000 6,500 7,000 33 38 43 48 53 58 63 68 73 78 83 88 93 40 45 50 55 60 65 70 75 80 85 90 95 100 48 53 58 63 68 73 78 83 88 93 98 103 108 Five Bedrooms 55 60 65 70 75 80 85 90 95 100 105 110 These fans are also built to take care of the homeowner’s spot ventilation needs when the room is occupied. The basic fan models allow a choice of three speeds. When fans are equipped with the optional Multi-Speed module, these models kick up to a maximum level of 150 CFM for the FV-11-15VKL1 and 110 CFM for the FV-05-11VKSL1 and FV-05-11VKL1 either when the switch is turned on or activated by the optional Condensation Sensor module or the optional Motion Sensor module. A High/Low Delay Timer, located inside the fan unit, is utilized to return the fan back to the pre-set Continuous ventilation mode. The installer needs to consult with the homeowner for the desired setting on the timer (0 - 60 minutes) and make the adjustments during the installation. DESCRIPTION These products are listed by UL under UL file No. E78414. These products use a sirocco fan driven by a DC motor powered by an integral transformer. The motor is designed to have long operating life, high dynamic response, higher speed ranges with saving energy. The grille covering the fan body is a spring-loaded, quick remove type. A damper for preventing air counter flow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level. The lighting unit is an energy-saving LED lighting device that uses two 7W LED lamps and produces almost the same illumination as a standard 60W incandescent lamp. FCC Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning this product on and off, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect equipment into outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Warning: This equipment must be installed by qualified person in accordance with the provided installation instructions; and all applicable codes and standards. Also, any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. DoC Responsible Party: Panasonic Corporation of North America Two Riverfront Plaza, Newark, NJ 07102 Customer Call Support: 1-866-292-7299 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Risk of Fire: Type IC-Inherently Protected, Only Use LED Lamp, Max 7W, Type GU24. UNPACKING Unpack and carefully remove the unit from carton. Refer to the Supplied Accessories list to verify that all parts are present. 4 SUPPLIED ACCESSORIES Part name Appearance Grille Quantity Part name 1 Installation instructions 2 Warranty sheet 1 Tapping screw (ST4.2X20) 4 Self-drilling screw 4 TM Flex-Z Fast bracket 1 7W LED lamp 2 Appearance Quantity DIMENSIONS 1 1/2 (38) 1 (26) Unit: inches (mm) 4 5/8 (116) FV-11-15VKL1 13 (330) 3 1/2 (88) 3 1/4 (81) 5 7/8 (148) 3 7/8 (98) 5 7/8 (148) FV-05-11VKL1 FV-11-15VKL1 10 1/4 (260) 12 1/8 (307) 13 6 3/8 (163) FV-11-15VKL1 FV-05-11VKSL1 No. 1 13 (330) 2 3 4 5 6 10 1/4 (260) 3 7/8 (100) 3 7/8 (100) 7 15 7 3/8 (190) 14 14 No. Part name Part name 8 Connector cover Blade 9 Base PCB box Grille 10 Pick-A-Flow switch Lens Motion sensor location 11 Lighting unit (FV-MSVK1 not included) 12 LED lamp 13 Fan body Junction box Adaptor 14 Damper Multi-Speed module (FV-05-11VKSL1 only, Flex-Z FastTM bracket 15 other models not included) WIRING DIAGRAM Junction box Fan body DC-Motor (114°C Fuse) Thermally protected Multi-Speed module (FV-05-11VKSL1 only, other models not included) Plug ‘N Play module slot Switch for power Black Live (Fan) White Neutral (Power supply) AC120V 60Hz Hi/Low switch: When plug in Multi-Speed module; On/Off switch: When plug in other Plug ‘N Play modules. Red Red (Non-powered control wires) Plug ‘N Play module slot Green Earth ground Green Switch for power LED lamp Black Live (Light) (Power supply) White Neutral AC120V 60Hz 5 FEATURE [For models of: FV-05-11VKSL1, FV-05-11VKL1, FV-11-15VKL1.] The WhisperGreen Select Line of ventilation fans employs innovative, state-of-the-art technologies that provide a number of customizable unique features that lead to improved indoor air quality. Please read the installation manual first in order to realize the benefits of this customizable, modular fan. Optimum Ventilation Performance: Duct length, elbows and other factors increase static pressure which can hinder the performance of most ventilation fans. This fan utilizes SmartFlow microchip technology that monitors the static pressure in the system and speeds up or slows down the rpm of the fan depending upon the amount of resistance within the ducts. This feature allows the fan to perform as rated and avoid potential installation issues. Outstanding Energy Savings: The WhisperGreen Select Line of fans are built using DC motor technology. The DC motor is 30% - 70% more energy efficient than the minimum ENERGY STAR requirements. Pick-A-Flow switch All the WhisperGreen Select base models of fans come with Pick-A-Flow speed options. The Pick-A-Flow switch on the face of all WhisperGreen Select fans allows the option to choose 50 – 80 – 110 CFM for the FV-05-11VKL1, FV-05-11VKSL1 or 110 – 130 – 150 CFM for the FV-11-15VKL1. These fans can run continuously or intermittently, depending upon the needs of the owner. 11-15 MODEL 110130150 AIR VOLUME (CFM ) 05-11 50 80 110 MODEL Pick-A-Flow Feature AIR VOLUME (CFM ) 05-11 50 80 110 MODEL 11-15 MODEL 110130150 Air volume type (CFM) FV-05-11VKSL1 50 FV-05-11VKL1 FV-11-15VKL1 110 Factory setting 80 110 80 CFM 130 150 130 CFM INDICATION (PLUG ‘N PLAY FUNCTION DEVICES) PLUG ‘N PLAY Modular Component Accessories Sold Separately, Not Included With Base Model Fan 11-15 MODEL 110130150 AIR VOLUME (CFM ) 05-11 50 80 110 MODEL Note that there is ONLY ONE Plug ‘N Play slot to insert the Multi-Speed module within the base model fan. There are TWO interchangeable Plug ‘N Play slots to insert the Condensation Sensor module, Motion Sensor module or Nite-GloTM LED Night Light module within the base model fan. FV-VS15VK1 Multi-Speed module allows the fan to run continuously at lower speeds to maintain ventilation standards to meet Indoor Air Quality and then boost up to high speed to meet intermittent needs for ‘Spot’ or ‘Point Source’ exhaust needs. The FV-VS15VK1 Modular Component will operate for both the FV-05-11VKL1 and the FV-11-15VKL1 matching the appropriate Multi-Speed setting shown below. The FV-05-11VKSL1 comes with the FV-VS15VK1 Multi-Speed module. It is not necessary to purchase this component. Note the options on the face of the FV-VS15VK1 Multi-Speed module to choose appropriate levels of airflow (CFM) and time delay before returning back to low speed (TIME). Choosing the Pick-A-Flow setting automatically adjusts the Multi-Speed setting accordingly. As an example, if the Pick-A-Flow Multi-speed setting is 80 CFM, the Multi-Speed settings adjust automatically to be 0, 30, 40, 50, 60 or 70 CFM at the lower speeds. The fan will ‘boost’ to the 80 CFM speed as the high speed setting. Selecting a particular TIME option will cause the fan to run for the selected amount of time before returning to the lower speed setting chosen on the CFM dial. Multi-Speed Air volume (CFM) Pick-A-Flow (CFM) FV-05-11VKSL1, FV-05-11VKL1 50 80 (plug-in FV-VS15VK1) 110 110 FV-11-15VKL1 130 (plug-in FV-VS15VK1) 150 Delay Time (min) 6 0 0 0 0 0 0 30 30 30 50 50 50 40 40 40 60 60 60 40 50 50 70 70 70 40 60 60 80 80 80 40 70 70 90 90 90 40 40 40 70 70 70 80 90 100 100 100 100 100 110 110 100 110 120 45 Factory setting: 20 minutes. Delay Time position “0“ : Manual wall switch control is 0 minute; without manual wall switch control is 0.5 minute. INDICATION (PLUG ‘N PLAY FUNCTION DEVICES) CONTINUED PLUG ‘N PLAY Modular Component Accessories Sold Separately, Not Included With Base Model Fan FV-CSVK1 Condensation Sensor module turns the base fan on or boosts to higher speed when humidity is detected when used in combination with the FV-VS15VK1. The Condensation Sensor works based on calculations from the Psychrometric Chart, or combination of Relative Humidity (RH) and Temperature. This allows the fan to anticipate the formation of condensation and automatically turn on when needed to expel humid air. The Condensation Sensor is pre-set to run for 20 minutes; it will then check the RH and Temperature to detect if the fan needs to run for another 20 minutes cycle. FV-MSVK1 Motion Sensor module turns the base fan on or boosts to higher speed when motion is detected when using in combination with the FV-VS15VK1. The Motion Sensor is pre-set to run for 20 minutes; it will then re-check for movement; if detected the fan will run for another 20 minutes cycle. The Motion Sensor detects within the range shown below. The distance that motion can be detected is limited to 10 feet (3m). The field of view of the sensor is 90°. (Room temperature is 25 C). FV-NLVK1 Nite-GloTM LED Night Light module automatically turns on when ambient light levels are met. Turning the dial on the Modular Nite-Glo Component to ‘DARK’ is ideal if the fan is in an isolated room with little ambient light from nearby rooms. Turning the dial to ‘BRIGHT’ is ideal if there is light spill from nearby rooms. (Note that it is necessary to connect wall switch when only plug in FV-NLVK1, fan can operate on high speed with wall switch control, fan can also operate on low speed when used in combination with the FV-VS15VK1.) MOTION (PLUG ‘N PLAY FUNCTION DEVICES) PLUG ‘N PLAY Modular Components used in Combinations PLUG ‘N PLAY Modular Component Accessories Sold Separately, Not Included With Base Model Fan FV-CSVK1 + FV-MSVK1 Turns the fan on for 20 minutes when either motion or excess humidity is detected. FV-CSVK1 + FV-VS15VK1 Cycles the fan to high speed from low speed for the amount of time selected on the Control Dial based upon detection of excess humidity. FV-MSVK1 + FV-VS15VK1 Fan active When motion or At low excess humidity is speed detected, fan runs at high speed. OUTSIDE Human active INSIDE Module FV-MSVK1, FV-CSVK1 (Not included) Cycles the fan to high speed from low speed for the amount of time selected on the Control Dial based upon motion within the room. Remains running at high speed until the delay time has passed. Motion FV-CSVK1 only FV-MSVK1 only FV-CSVK1 + FV-VS15VK1 FV-MSVK1 + FV-VS15VK1 Fan operation Time delay operation Fan ON/OFF 20 minutes time delay Fan Hi/Low speed Depend on FV-VS15VK1 Time delay setting 7 INSTALLATION (PLUG ‘N PLAY FUNCTION DEVICES) You can purchase the specified Plug ‘N Play devices that are explained on page 6-7 and install them in positions , 2 and 3 . Position can only be used with Multi-Speed module (model FV-05-11VKSL1 already have this control installed), position 2 and 3 can be used for any of the other optional control modules. 1. Remove the connector cover from position , 2 or 3 . 2. Plug in the specified devices to Base PCB box and fix to the slot, till hear the sound installed in place. Connector cover Base PCB box Slot 2 2 3 3 Clasp Squeeze tabs on the Clasp to remove. Squeeze, insert and release the tabs on Clasp to replace. INSTALLATION (NEW CONSTRUCTION) The fan position between joists from 16" to 24" on center can be adjusted flexibly. Adaptor Machine screw (M4X6) CAUTION Please wear gloves during the installation work as follow. Fig.1 Fan body 1. Disconnet plug connector from receptacle and remove adaptor from fan body by removing the machine screw (M4X6) before installation. (Fig.1) Joist IMPORTANT: Remove the tape from damper and adaptor before installation. As shown below: Adaptor Bend down 4 tabs Damper 2 Tapping screws (ST4.2X20) Fig.2 Tape 2. Bend down 4 tabs for positioning, install the Flex-Z FastTM bracket to joists by using 2 tapping screws (ST4.2X20) (Please prepare the screws and put on Flex-Z FastTM bracket before Flex-Z FastTM bracket is installed on joist). (Fig.2) 3. Adjust the length of Flex-Z FastTM bracket as the spacing between joists, and install to joists by using 2 tapping screws (ST4.2X20). (Fig.3) 4. Remove junction box cover and secure conduit or stress relief to junction box knock-out hole. (Fig.4) 5. Install a circular duct and secure it with clamps, or ties and seal it with mastic or approved foil tape. 4 inch 6 inch circular duct is needed to connect to relevant part of common adaptor. (Fig.4) 6. Install the adaptor to Flex-Z FastTM bracket by using 2 self-drilling screws. (Fig.4) 8 Joist 2 Tapping screws (ST4.2X20) Fig.3 Circular duct Conduit Mastic or approved foil tape Knock-out hole Junction box cover 2 Self-drilling screws Fig.4 INSTALLATION (NEW CONSTRUCTION) CONTINUED 7. Refer to wiring diagram on page 5. Follow all the local electrical safety codes as well as the National Electrical Code (NEC). Using UL approved wire nuts, connect house power wires to ventilating fan wires. (Fig.5) CAUTION Mount junction box cover carefully so that lead wires are not pinched. 8. Insert fan body and slide into adaptor assy with some strength, untill the flange overlaps the Flex-Z FastTM bracket. Secure the fan body to Flex-Z FastTM bracket by using 2 self-drilling screws, plug connector to receptacle and secure the fan body to adaptor by using machine screw (M4X6). (Fig.6) CAUTION Secure machine screw (M4X6) to the suitable hole and not touch the Flex-Z FastTM bracket. Please fix the screw carefully to avoid screw slip teeth. FV-05-11VKSL1 FV-05-11VKL1 FV-11-15VKL1 Earth ground to green Wire nut Junction box Live to black (Fan) Netural to white Netural to white Two red wires (Connect to a general manual wall switch) Live to black (Light) Fig.5 Joist Plug connector Machine screw (M4X6) 2 Self-drilling screws Receptacle 9. Finish ceiling work. Ceiling hole should be aligned with the inside edge of the flange. (Fig.7) ) /2 10 1 (270 Ceiling Fig.6 Unit: inches (mm) 10 1/2 0) (27 10. Remove the tapes from louver and springs before installation. Remove screw (M4X8) and light cover. (Fig.8) Conduit IMPORTANT: Replace the sensor cover before the installation (only for plug-in Motion sensor module FV-MSVK1). As shown below: Keep on pressing the clasps when removing the ornamental cover. Gloves After finishing the ceiling job, fill gap between flange and ceillng with caulk or other sealant to prevent air leakage Fig.7 Remove screw (M4X8) Tapes Ornamental cover Light cover Fig.8 Insert the sensor cover (attachment for FV-MSVK1) into slot. Sensor cover LED lamp Fig.9 Secure screw (M4X8) 11. Install the LED lamps. (Fig.9) 12. Install light cover. (Fig.10) 13. Insert the grille mounting spring on the wiring side into the slot and insert the plug connector into the housing of the lighting unit. (Fig.11 of page 10) Light cover Fig.10 9 INSTALLATION (NEW CONSTRUCTION) CONTINUED Ceiling Plug connector CAUTION Before turn on the light, make sure the connector at the correct position. If not, the lighting can’t work. Mounting spring Motion sensor (FV-MSVK1 only) Clasp Lighting Gloves unit The claw of connector must latch the rib completely. 14. Plug in the specified devices as your choice (refer to installation on page 8). Insert the motion sensor (FV-MSVK1 only) or LED night light (FV-NLVK1 only) into slot of the grille. Fix the lead wire into the clasp (Fig.11). LED night light (FV-NLVK1 only) Rib Inser plug connector Claw Fig.11 Ceiling 15. Adjust Pick-A-Flow switch; if used, adjust the FV-VS15VK1 Multi-Speed module. (Fig.12) Refer to indication on page 6. Grille 16. Insert the other mounting spring into the slot as shown and mount grille to fan body. (Fig.13) Fig.12 Ceiling CAUTION Mount grille carefully so that lead wire of lighting unit is not pinched. Mounting spring Gloves Grille Fig.13 INSTALLATION (RETROFIT) Conduit Circular duct WARNING Joist bracket by using 4. Secure the fan body to Flex-Z FastTM bracket by using 2 self-drilling screws, plug connector to receptacle and secure the fan body to adaptor by using machine screw (M4X6). (Fig.16) 10 7/8 (275) Circular duct Conduit 5) 3. Install the adaptor to Flex-Z Fast 2 self-drilling screws. (Fig.15) Ceiling (already existed) (27 2. Follow the step 1, 4, 5 on page 8 and step 7 on page 9. (Before connect the circular duct to the adaptor, should pull down the circular duct from the ceiling) 4 Tapping screws (ST4.2x20) 7/8 1. Remove the existing fan and cut ceiling openning. Secure the Flex-Z FastTM bracket to joists by using 4 tapping screws (ST4.2x20) (Please prepare the screws and put on Flex-Z FastTM bracket before Flex-Z FastTM bracket is installed on joist). Existing ductwork and wiring left in place. (Fig.14) 10 Disconnect power source before working on unit. TM Unit: inches (mm) Fig.14 Mastic or approved foil tape Joist Knock-out hole Junction box cover Ceiling 2 Self-drilling screws Fig.15 Joist CAUTION Secure machine screw (M4X6) to the suitable hole and not touch the Flex-Z FastTM bracket. Please fix the screw carefully to avoid screw slip teeth. 5. Follow the step 10 to 16 on page 9 to 10. 10 Ceiling Machine screw (M4X6) Flange 2 Self-drilling screws (Fix the Fig.16 flange and Flex-Z FastTM bracket through the ceiling) MAINTENANCE (CLEANING) WARNING Gloves Disconnect power source before working on unit. Fig.17 CAUTION Ceiling Routine maintenance must be done every year. Please wear gloves during the cleaning work. Never use gasoline, benzene, thinner or any other such chemicals for cleaning the ventilating fan. Vacuum cleaner Do not immerse motor in water when cleaning. Do not soak resin parts in water over 140 F (60 C). Fig.18 1. Clean grille. (Don’t put into hot water. Use non-abrasive kitchen detergent, wipe dry with clean cloth) (Fig.17) Ceiling 2. The grille should be dry after cleaning. 3. Remove dust and dirt from fan body using a vacuum cleaner. (Fig.18) 4. Using a cloth dampened with kitchen detergent, remove any dirt from fan body. Wipe dry with clean cloth. (Fig.19) 5. Reinstall grille. MAINTENANCE Gloves Fig.19 (REPLACEMENT OF LAMP) WARNING Disconnect power source before working on unit. The lamp’s glass is fragile, be careful when the lamp is replaced. Make sure the temperature of lens and lighting unit has cooled down before maintenance (cleaning) or replacement of lamp. CAUTION Remove dust and dirt from light cover and lens, before replace the lamps. Motion sensor (FV-MSVK1 only) Clasp Gloves LED night light (FV-NLVK1 only) Rib Claw The LED lamps should be replaced as the specified type. The supplied LED lamps are not intended for other use. Remove plug connector Lighting unit Grille Fig.20 Remove screw (M4X8) 1. Remove grille by pulling down one mounting spring (Fig.20). Remove plug connector then pull down the other. (For models plug-in FV-MSVK1 or FV-NLVK1: Pull down the mounting spring that without lead wire passed side, and remove motion sensor or LED night light as shown in Fig.20) (Squeeze mounting spring and pull down carefully) 2. Remove the screw as shown in step of Fig.21. Remove the light cover as shown in step of Fig.21. Mounting spring Ceiling Plug connector Light cover Fig.21 Lens 3. Replace the LED lamps (CX-GU24-H-B, 7W) as shown in step 1 and step 2 of Fig.22. 4. Install the LED lamps (CX-GU24-H-B, 7W) as shown in step 1 and step 2 of Fig.9 (Page 9). LED lamp Fig.22 5. Install light cover. (Fig.10 of page 9) 11 PRACTICAL GUIDE TO INSTALLATION Properly insulate the area around the fan to minimize building heat loss and gain. (Fig.23) Loose fill or batt insulation can be placed directly over the fan housing in the attic. Our fans and fan/light combination units do not create excessive heat that is a common problem with recessed light fixtures or some competitor’s fan/light combination. Our efficient, cool-running motors and our LED lighting unit do not create enough ambient heat to be subjected to these limitations. 4 inches or 6 inches roof jack, wall cap, or soffit vent with backdraft damper Mechanically connect duct to termination and seal with mastic or approved foil faced tape 2-3 ft straight run before elbow In attic installation, caulk box to drywall Short piece of flexible duct helps Insulation alignment and absorbs sound. Clamps plus mastic or approved Foil tape tightly covers all metal 3 foil faced tape at all flex joints duct joints (glue PVC joints) SPECIFICATIONS Specifications for Base Model fans Model No. Duct Air Voltage Frequency diameter direction (V) (Hz) (inches) FV-05-11VKSL1 Exhaust FV-05-11VKL1 FV-11-15VKL1 Air volume at 0.1"WG (CFM) 50 80 110 110 130 4 or 6 Exhaust 150 Power (W) Noise (sones) Speed (rpm) Fan <0.3 <0.3 0.4 <0.3 <0.3 0.6 750 825 965 650 680 730 3.6 6.0 11.0 8.5 12.0 16.5 Lighting unit Weight lb. 14 11.5(5.2) 14 11.7(5.3) HVI Certified performance based on HVI Procedures 915, 916, and 920. Specifications for Multi Speed fans Model No. Duct Air Voltage Frequency diameter direction (V) (Hz) (inches) Air volume at 0.1"WG (CFM) FV-05-11VKSL1, FV-05-11VKL1 (Plug-in FV-VS15VK1) FV-11-15VKL1 (Plug-in FV-VS15VK1) Exhaust Exhaust 100 90 80 70 60 50 40 30 0 120 110 100 90 80 70 60 50 0 Power (W) Noise (sones) Speed (rpm) Fan <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 915 865 825 795 770 750 730 725 8.7 7.0 6.0 4.7 3.9 3.6 2.8 2.5 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 665 650 645 640 635 630 625 620 9.5 8.5 6.9 5.7 5.0 4.3 4.0 3.2 Lighting unit Weight lb. 14 11.5(5.2) 14 11.7(5.3) Reference performance based on HVI Procedures 915, 916, and 920. [(*) Standby wattage.] PRODUCT SERVICE Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only. Your product is designed and manufactured to ensure a minimum of maintenance. Should your unit require service or parts, call Panasonic Call Center at 1-866-292-7299 (USA) or 1-800-669-5165 (Canada). Panasonic Corporation of North America Two Riverfront Plaza, Newark, NJ 07102 www.panasonic.com Panasonic Canada lnc. 5770 Ambler Drive, Mississauga, Ontario L4W 2T3 www.panasonic.ca Panasonic corporation 2014 Printed in China X0114-2024 11KSL1420B
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Create Date : 2014:03:24 14:29:11-04:00 Creator Tool : CorelDRAW X5 Modify Date : 2014:03:24 14:29:11-04:00 Metadata Date : 2014:03:24 14:03:02-04:00 Format : application/pdf Creator : R&D Title : 05-11VKSL1 (English).cdr Producer : Acrobat Distiller 8.0.0 (Windows) Document ID : uuid:21ff87f5-162b-4560-b35a-3897a5a03eab Instance ID : uuid:3b9f4311-de61-4e66-872f-a06cf684302a Page Count : 12 Author : R&DEXIF Metadata provided by EXIF.tools