Paradox Security Systems 1759MG Spectra 1759MG User Manual 1759MGEI05

Paradox Security Systems Spectra 1759MG 1759MGEI05

Contents

Installation instructions

1759MG V2.0Reference & Installation Manual(433MHZ / 868MHZ)1759MG
Spectra SeriesTable of ContentsIntroduction...................................................................... 1Features.............................................................................................. 1Specifications...................................................................................... 1Installation........................................................................ 2Location and Mounting ....................................................................... 2Earth Ground ...................................................................................... 2AC Power............................................................................................ 2Backup Battery ................................................................................... 2Auxiliary Power Terminals*................................................................. 4Telephone Line Connection................................................................ 4Bell Output Connection....................................................................... 4Programmable Output Connections* .................................................. 4Single Zone Inputs.............................................................................. 5Keypad and Keypad Zone Connections     ......................................... 5Keyswitch Connections....................................................................... 6Fire Circuits......................................................................................... 6Programming Methods.................................................... 7WinLoad Software for Windows* ........................................................ 7Programming Using a Keypad............................................................ 7Configuring The LED Keypad ............................................................. 8Programming Using A Paradox Memory Key*.................................... 9Access Codes ................................................................ 10Access Code Length......................................................................... 10Installer Code (Default: 0000 / 000000)............................................ 10System Master Code (Default: 1234 / 123456)................................. 10User Code Options ........................................................................... 10Lock Master Code............................................................................. 11Duress Code..................................................................................... 11Zone Programming........................................................ 12What is an Expansion Input? ............................................................ 12Reassign Keypad Zone 2 ................................................................. 12Reassign Zones to Expansion Inputs ............................................... 13Zone Programming ........................................................................... 13Zone Definitions................................................................................ 13Exclusive Zone Definitions................................................................ 14Programming a Wireless Fire Zone .................................................. 15Zone Partition Assignment................................................................ 15Zone Options .................................................................................... 16Zone Speed ...................................................................................... 17EOL Zones........................................................................................ 17Wireless Features.......................................................... 18Wireless Transmitter Programming .................................................. 18Viewing the Wireless Transmitter Signal Strength............................ 19Serial Number Display ...................................................................... 19Supervision Options.......................................................................... 19Remote Control Programming .......................................................... 20Arming and Disarming Options.................................... 22Switch To Stay Arming ..................................................................... 22Stay Arming with Delay..................................................................... 22Regular Arming Switches to Force Arming (Not to be used with UL Installations) ............................................... 23Restrict Arming on Battery Fail ......................................................... 23Restrict Arming on Tamper Failure................................................... 23Timed Auto-Arming........................................................................... 23No Movement Auto-Arming .............................................................. 23Auto-Arming Options (Not to be used with UL installations)............. 24One-Touch Arming (Not to be used with UL installations)................ 24Exit Delay .........................................................................................  24Bell Squawk On Arm/Disarm with Keypad .......................................  24Bell Squawk On Arm/Disarm with Remote Control ..........................  24No Exit Delay When Arming with Remote Control ...........................  24No Exit Delay Beeps and No Bell Squawk When Stay Arming........  25 Alarm Options............................................................... 25Bell Cut-Off Timer.............................................................................  25Recycle Alarm ..................................................................................  25Tamper Recognition.........................................................................  25Keypad Panic Options......................................................................  26Panic Lockout Timer.........................................................................  26Reporting and Dialer settings....................................... 27Reporting/Dialer (Enable/Disable)....................................................  28Report Codes ...................................................................................  28Monitoring Station Telephone Numbers...........................................  30Partition Account Numbers...............................................................  30Reporting Formats............................................................................  30Pager Delay......................................................................................  32Event Call Direction..........................................................................  32Dialing Method .................................................................................  32Pulse Ratio.......................................................................................  32Bell on Communication Failure ........................................................  32Dial Tone Delay................................................................................  32Maximum Dialing Attempts...............................................................  33Delay Between Dialing Attempts......................................................  33Alternate Dial Option ........................................................................  33Recent Close Delay..........................................................................  33Auto Test Report ..............................................................................  33Closing Delinquency Timer ..............................................................  33Power Failure Report Delay .............................................................  33Disarm Reporting Options................................................................  33Zone Restore Report Options ..........................................................  34Telephone Line Monitoring (TLM) ....................................................  34 Programmable Outputs................................................ 34PGM Activation Event ......................................................................  34PGM Deactivation Event ..................................................................  35PGM Delay.......................................................................................  35PGM Normal State ...........................................................................  35PGM2 Strobe Options ......................................................................  35Alarm Relay Options ........................................................................  35System Settings............................................................. 36Hardware Reset ...............................................................................  36Installer Lock ....................................................................................  36Keypad Lockout Feature ..................................................................  36Battery Charge Current ....................................................................  36Partitioning .......................................................................................  36System Real-Time Clock..................................................................  36Clock Adjust .....................................................................................  36Keypad Tamper Supervision............................................................  37Keypad Audible Trouble Warning.....................................................  37Confidential Mode ............................................................................  37Installer Quick Functions Keys.........................................................  38PGM Modules Supervision...............................................................  38Printer Module Supervision ..............................................................  38Zone Expansion Bus Module Supervision........................................  38Wireless Transmitter Low Battery Supervision.................................  39Wireless Transmitter Supervision Options .......................................  39Reprogram All Expansion Modules..................................................  39
Reference & Installation Manual   Settings for WinLoad Software .................................... 40Panel Answer Options ...................................................................... 40Panel Identifier.................................................................................. 40PC Password .................................................................................... 40PC Telephone Number ..................................................................... 40Call WinLoad Software ..................................................................... 40Answer WinLoad Software ............................................................... 41Auto Event Buffer Transmission ....................................................... 41Call Back WinLoad ........................................................................... 41 User Operation.............................................................. 42Trouble Display................................................................................. 42Programming Access Codes ............................................................ 43Disarming & Deactivating an Alarm .................................................. 43Regular Arming................................................................................. 44Stay Arming ...................................................................................... 44Instant Arming................................................................................... 44Force Arming (Not to be used with UL Installations) ........................ 44Manual Bypass Programming........................................................... 44One-Touch Arming ........................................................................... 45Keyswitch Arming ............................................................................. 45Panic Alarms..................................................................................... 45Auto-Arming (Not to be used with UL installations) .......................... 45Alarm Memory Display...................................................................... 46Programming Chime Zones.............................................................. 46Keypad Muting (Not to be used with UL installations) ...................... 46Keypad Backlight (1686H and 1686V only) ...................................... 46FCC Warnings................................................................  47Index ............................................................................... 49List of TablesTransformer Requirements Table....................................................... 2Current Consumption Table................................................................ 4Decimal and Hexadecimal Programming Table ................................. 7Zone Recognition Table  .................................................................. 12Sections and Expansion Inputs ........................................................ 18Remote Control Button Programming............................................... 21Button Options.................................................................................. 22Special Keys for Telephone Numbers .............................................. 30Reporting Formats............................................................................ 31Zone Tamper Report Code for Keypad Tamper Supervision Failure.. 37Trouble List ....................................................................................... 42
Spectra 1759MG   1Part 1: Introduction1.1 Features• Up to 15 fully programmable zones• Two completely independent partitions. Many of the features and options in the Spectra System can be independently set for each partition such as Event Reporting, Entry/Exit Delay, Auto-arming and many more. All zones, the keyswitches and all user codes are assigned to specific partitions, which makes this a true partitioned system.• Communication bus facilitates the adding, programming and monitoring of all expansion modules • 1 Installer Code and 48 user codes (including: 1 System Master, 2 Masters, and 1 Duress)• 2 on-board, fully programmable outputs (PGMs) and one 5A alarm relay• Simple, direct and logical programming• Event Call Direction: The Spectra 1759MG control panel events are divided into 5 groups of events. Each of these event groups can be programmed with a separate dialing sequence.• Two 32-digit monitoring station telephone numbers and one 32-digit Backup Telephone Number • Contact ID, Pager Format and many more High-Speed Communication Formats• "False Alarm Prevention" features such as: Intellizone, Auto Zone Shutdown, Beep on Exit Delay, Programmable Delay Before Alarm Transmission, and Recent Closing Report• Regular arming, Stay arming, Instant arming, Force arming, One-touch arming, Auto-arming, or Keyswitch arming  • 256 Event Buffer with time stamp• Telephone Line Supervision• Keypad activated panic alarms• Compatible with Winload Security System Management Software for Windows®1.2 Specifications1.2.1 Spectra 1759MG Control Panel• AC Power: 16Vac transformer (refer to Table 1 on page 2) with minimum 20VA rating (Rec.: 40VA), 50 to 60Hz • Battery: 12Vdc, 4Ah/7Ah •Aux. Power:+600mA typical, 700mA maximum, fuseless shutdown @ 1.1A• Bell Output:++ 1A, fuseless shutdown @ 3A• PGM Outputs: PGM1 = 150mA low-current output, PGM2 = 1A high-current output• Alarm Relay: One form “C” relay rated @ 125V, 5A receptive load• Approvals: 433MHz 868MHz  Compliant to all EU and EFTA countries except Greece accordingto RTT&E directives.1.2.2 Spectra Keypads (1686H, 1686V, 1689 and 1641)• Power input: Typically 9-16Vdc• 1 standard keypad zone• On-board anti-tamper switch (optional)1686H and 1686V 10-Zone LED Keypad• Current consumption: 62 to 116mA1689 16-Zone LED Keypad• Current consumption: 50 to 117mA1641 32-Character LCD Keypad• Current consumption: 60 to 80mA• PGM: 1 with 50mA current limit• LCD:  Super Twisted Nematic display (STN), Wide viewing angle, Backlight & Contrast adjustableSpecifications may change without prior notice+ Cannot exceed 200mA for UL installations++ Cannot exceed 1A for UL installations
2   Reference & Installation Manual   Part 2: Installation2.1 Location and MountingBefore mounting the cabinet, push the five white nylon mounting studs into the back of the cabinet. Pull all cables into the cabinet and prepare them for connection before mounting the circuit board into the back of the cabinet. Select a centralized installation site on the main floor that isn't easily accessible to intruders and leave at least 5cm (2in) around the panel box to permit adequate ventilation and heat dissipation. The installation site should be dry and close to an AC source, ground connection and telephone line connection. Avoid installation near or in the path of strong RF fields (i.e. neon lights, computers), on or near metal objects, circuit breaker boxes, air conditioners and heater ducts since they may cause interference and reduce sensitivity. Avoid installing the 1759MG in the basement. Do not cut, bend or alter the antennae and ensure that electrical wires do not cross over the antennae as these may affect the signal reception.2.2 Earth GroundConnect the zone and dialer ground terminals from the control panel to the metallic enclosure and cold water pipe or grounding rod as per local electrical codes. For maximum lightning protection, use separate earth grounds for the zone and dialer grounds as shown in Figure 2 on page 3. For UL installations, the metallic enclosure must be grounded to the cold water pipe.2.3 AC PowerDo not use any switch-controlled outlets to power the transformer. Connect the transformer as shown in Figure 1 on page 2. Use Table 1 to determine the required transformer.2.4 Backup BatteryTo provide power during a power loss, connect a 12Vdc 4Ah rechargeable acid/lead or gel cell backup battery as shown in Figure 1 on page 2. Use a 7Ah battery to comply with UL fire requirements. Connect the backup battery after applying AC power. When installing, verify proper polarity as reversed connections will blow the battery fuse. Also, refer to Battery Charge Current on page 36.2.4.1 Battery TestIf the battery is disconnected or if the battery fuse is blown, a No/Low Battery failure will appear in the keypad’s trouble display (see page 42). This trouble will also appear if the battery’s capacity is too low or if the voltage drops to 10.5V or lower while the control panel is running on the backup battery. At 8.5V or lower, the panel shuts down and all outputs close.Figure 1: AC Power and Backup Battery ConnectionsTable 1: Transformer Requirements TableTransformer: Amseco XP-1620 16VAC 20VA(not verified by UL) UL: Basler Electric BE156240CAA00716.5VAC 40VASpectra DC Power Supply rated at: 1.2A 1.5AAuxiliary Supply can provide a maximum of: typ: 600mA, max: 700mA typ: 600mA, max: 700mADo not exceed 200mA for UL installationsAcceptable Battery Charge Currents 350mA 350mA/700mAUL Warning:A 12Vdc / 7Ah battery is required to comply with UL fire requirements.Caution:Disconnect battery before replacing the fuse.Improper connection of the transformer may result in damage to the system.Rechargeable BatteryUL/ULC - 12Vdc / 4Ah or 7AhPartial view of Spectra 1759MG control panel
Spectra 1759MG   3Figure 2: Spectra 1759MG Control Panel OverviewTo connect the 5A Alarm Relay and the PGMs, refer to Relay and PGM Connections on page 5. To connect AC power, refer to AC Power and Backup Battery Connections on page 2. For UL Listed Warnings, refer to UL AND ULC WARNINGS on page 48.Warning: Do not cut, bend or alter the antennae & ensure that electrical wires do not cross over the antennae as these may affect the signal reception.“STATUS” LED:Flash once every second = normalON 1 second and OFF 1 second = troubleAlways ON = panel is using phone lineFast flash 4 seconds after power up = installer lock enabled“RX” LED:Flashes quickly when receiving signals from wireless devices. AntennaeWarning: Disconnect telephone line before servicing.Paradox Memory Key (PMC-3)Reset JumperFour pin connector can be used for the quick installation of a Spectra keypad or Expansion Module.The “BELL” output will shut down if the current exceeds 3A.Communication BusTo provide maximum lightning protection, we strongly recommend having separate earth connections for the dialer and zone ground terminals.AWG#14 single conductor solid copper wireCold water pipe groundingGround clampTo metallic enclosureSpectra KeypadsThe maximum number of keypads per installation is dependent on the auxiliary output, which cannot exceed 700mA.AUX PowerRefer to Transformer Requirements Table on page 2 for Aux. Power Output. To connect additional wiring to auxiliary power, use the red (+) and black (-) keypad connectors. Auxiliary power will shut down if current exceeds 1.1A. If the auxiliary output is overloaded and is shut down, you must disconnect all loads from the output for at least 10 seconds before reconnecting any load back to the auxiliary output.A door contact or any other detection device can be connected to the Keypad Zone.Warning: Do not connect keypads more than 76m (250ft) from the control panel.For the keypad’s zone, EOL and tamper configurations, refer to Configuring The LED Keypad on page 8.Refer to Single Zone Inputs on page 5.Refer to AC Power and Backup Battery Connections on page 2.
4   Reference & Installation Manual   2.5 Auxiliary Power Terminals*The auxiliary power supply terminals can be used to power motion detectors, keypads and other modules or accessories in the security system. A fuseless circuit protects the power supply against current overload and automatically shuts down if the current exceeds 1.1A. If this occurs, the Maximum Auxiliary Current failure will appear in the keypad’s trouble display (see page 42). Therefore, the combined current consumption of devices connected to the auxiliary power supply should not exceed 700mA. If the auxiliary output is overloaded and is shut down, you must disconnect all loads from the output for at least 10 seconds before reconnecting any load back to the auxiliary output.Modules with the APR- prefix are compatible with the Spectra 1759MG and DGP-848. Modules with the APR3- prefix are compatible with the Spectra 1759MG, DGP-848 and DGP-NE96.2.6 Telephone Line ConnectionIn order to report system events to the monitoring station, you must connect the incoming telephone company wires into the TIP and RING connections of the control panel and then run the wires from T1 and R1 to the telephone or telephone system as shown in Figure 2 on page 3.2.7 Bell Output ConnectionThe BELL+ and BELL- terminals power bells, sirens and other warning devices requiring a steady voltage output during an alarm. The bell output supplies 12Vdc upon alarm and can support one 30-watt or two 20-watt sirens. The bell output uses a fuseless circuit and will automatically shut down if the current exceeds 3A. When this occurs the Maximum Bell Current failure will only appear in the keypad’s trouble display (see page 42) during an alarm. If the load on the BELL terminals returns to normal, the control panel will re-instate power to the BELL terminals during the next alarm. When connecting sirens, please verify correct polarity. Connect the positive lead to the BELL+ terminal and the negative lead to the BELL- terminal of the control panel as shown in Figure 2 on page 3.   If the BELL output is not being used, the Bell Disconnected failure will remain in the keypad’s trouble display (see page 42). To avoid this connect a 1KΩ resistor across the BELL terminals. 2.8 Programmable Output Connections*When a specific event occurs in the system, a PGM can reset smoke detectors, activate strobe lights, open/close garage doors and much more.2.8.1 Alarm Relay and PGMs The Spectra 1759MG control panel includes two on-board programmable outputs (PGMs). For details on how to program the PGM, refer to PGM Programming on page 34. PGM1 can support up to 150mA while PGM2 supports up to 1A (see Figure 3 on page 5) and can be used as a strobe output (see page 35). The PGMs are limited by the power source being used. If powered by:•The AUX terminals. The current consumption of the AUX terminals cannot exceed 700mA. Therefore, whatever devices are connected to the AUX terminals (i.e. modules and PGMs) cannot exceed 700mA combined. For example, if there are six modules connected to the AUX terminals that are using 600mA and you wish to power the PGM using the AUX terminals, the PGM’s current consumption cannot exceed 100mA.•An external power supply. If using an external power supply, the current consumption cannot exceed 150mA for PGM1 and 1A for PGM2. If the external power supply’s current consumption limit is less than that of the PGM it is connected to, than the current consumption will not exceed the power supply’s current limit.  The Spectra 1759MG control panel also has a 5A relay. This relay can be connected as shown in Figure 3 on page 5. The Alarm Relay can be programmed to follow the bell output or the activation and deactivation of the Global PGM (see Alarm Relay Options on page 35).* UL Note: The AUX and PGM terminals cannot exceed 200mA for UL installations.Table 2: Current Consumption TableModules Current ConsumptionTypical MaximumSpectra 1686H and 1686V 10-Zone LED Keypad 62mA  116mASpectra 1689 16-Zone LED Keypad 50mA  117mASpectra 1641 LCD Keypad 60mA  80mA4-Zone Hardwire Modules (APR3-ZX4/SPC-ZX4) 12mA  12mA8-Zone Hardwire Modules (APR3-ZX8/SPC-ZX8) 30mA  30mA4-PGM Output Module (APR3-PGM4) 13mA  150mAPrinter Module (APR3-PRT1) 22mA  40mAInTouch Voice-Assisted Arm/Disarm Module (APR3-ADM2) 70mA 105mAMotion Detectors (see detector instructions for details) 10 to 50mA
Spectra 1759MG   5Figure 3: Relay and PGM Connections2.9 Single Zone InputsDetection devices such as motion detectors and door contacts are connected to the control panel's zone input terminals. Figure 4  demonstrates single zone input terminal connections recognized by Spectra. Once connected, the associated zone's parameters must be defined. For details refer to Zone Programming on page 12. Figure 4: Single Zone Input Connections2.10 Keypad and Keypad Zone Connections     To connect the keypads to the control panel, remove the back cover and wire the GRN, YEL, RED, and BLK terminals of each keypad to the corresponding terminals on the control panel as shown in Figure 2 on page 3. There is no limit to the number of keypads that can be connected to the control panel as long as the current consumption does not surpass 700mA*. See Keypad Tamper Supervision on page 37.Each keypad has one zone input terminal, allowing you to connect one motion detector or door contact directly to a keypad. The Alarm Relay (5A) can be programmed to follow the BELL output or the Global PGM.Any device such as a strobe light or sirenExternal Power SupplyAUX+ or External Power Supply. See Programmable Output Connections* on page 4.* UL Note: Cannot exceed 200mA for UL installations.
6   Reference & Installation Manual   keypad can then communicate the status of the zone to the control panel. A maximum of two keypad zones can be used with each control panel. After connecting the device, the zone's parameters must be defined. For details on zone recognition and  Zone Programming on page 12. Also, refer to the feature Reassign Keypad Zone 2 on page 12.Example: A door contact located at the entry point of an establishment can be wired directly to the input terminal of the entry point keypad instead of wiring the door contact all the way to the control panel. Figure 5: Keypad Zone ConnectionsWhen a 1641 LCD keypad is connected to the 1759MG, the Keypad Zone Sending option (Option [2] key [1]) determines whether the status of the keypad zone will be transmitted to the control panel. The Keypad Zone Sending option of the 1641 keypad must be enabled during the following conditions:• If you are using both keypad zones and at least one is from a 1641 keypad.• If you are using the keypad zones of other types of keypads, such as a 1686H 10-zone LED keypad, and the keypad zone definition of the 1641 keypad (keypad zone 1 or keypad zone 2; Option [2] key [3]) matches that of another connected keypad.2.11 Keyswitch ConnectionsKeyswitches allow users to arm or disarm a partition by pushing a button or by activating a switch with a key. Connect the keyswitch (as shown in Figure 6) directly to the control panel terminals. Once a keyswitch is connected, it must be assigned to a zone and its parameters must be programmed (see Zone Programming on page 12 and Keyswitch Options on page 17).2.12 Fire CircuitsWhen a zone is programmed as a fire zone, the zone becomes normally open and requires an EOL resistor. If a line short occurs or if the smoke detector becomes active, whether the system is armed or disarmed, the control panel will generate an alarm. If a trouble occurs on a fire zone, the Fire Loop Trouble will appear in the keypad’s trouble display (see page 42) and the control panel can transmit the Fire Loop Trouble report, if programmed, in section [206]. 2.12.1 4-Wire Installation:Any on-board zone can be defined as a fire zone (see page 13) when using the 4-wire installation. Connect the smoke detectors (as shown in Figure 7) directly to the control panel terminals. Program the PGM with the “[PG]/[FNC1] Key was Pressed” Activation Event (see page 34) so the smoke detectors can be reset by pressing the [PG] or [FNC1] key. Pressing the [PG] or [FNC1] key will interrupt power to the smoke detectors for 4 seconds (see PGM Delay on page 35).  It is recommended that all smoke detectors be connected using a daisy chain configuration.Do not place a jumper across the zone and “BLK” input terminals of the keypads that are not using their keypad zones.1641 LCD Keypad(Not using keypad zone)Be sure to enable option [1] (“Keypad Zone Sending”) of option [2] (“Options”) in the 1641’s LCD Programming Mode.A door contact or any other detection device 1686H(Not using keypad zone)1686H(Using keypad zone)Figure 6: KeyswitchFigure 7: Fire Zones
Spectra 1759MG   7Part 3: Programming Methods3.1 WinLoad Software for Windows*Program the Spectra Series control panels remotely or on-site using the Winload Software for Windows®. For more information, contact your local Paradox Distributor or visit our web site at www.paradox.ca. If you are using the WinLoad software, you must program the features explained on pages 40 and 41.* Not investigated by UL.3.2 Programming Using a KeypadUse the supplied Spectra 1759MG Programming Guide to keep track of which sections were programmed and how. We recommend you read this entire manual before you begin programming. 3.2.1 Single Digit Data Entry Method (Hexadecimal and Decimal)Single Digit Data Entry is used in all sections except those specified in the Feature Select Programming Method (below). After entering Programming Mode as described in the shaded box above, some sections will require that you enter Decimal values from 000 to 255. Other sections will require that you enter Hexadecimal values from 0 to F. The required data will be clearly indicated in this manual as well as in the Spectra 1759MG Programming Guide. When entering the final digit in a section, the control panel will automatically save and advance to the next section. Except sections 001 to 016, after entering the first two digits the control panel will switch to Feature Select Programming.  3.2.2 Feature Select Programming MethodAfter entering sections [001] to [016], [126] to [138], and [302] to [348], each option from [1] to [8] represents a specific feature or option. Press the key corresponding to the desired option and the corresponding light will illuminate or the option number will appear in the LCD display. This means the option is on. Press the key again to extinguish the corresponding light or remove the digit from the LCD display, thereby, turning off the option. Press the [FORCE] key to set all 8 options to off. Press the keys until the current section’s options are set. When the options are set, press the [ENTER] key to save and advance to the next section. 3.2.3 Data Display Mode (LED Keypads Only)In the Data Display Mode you can view the programmed contents of each section one digit at a time. After entering the desired 3-digit section (see step 3 of the shaded box on page 7), press the [ENTER] key to access the Data Display Mode (will not function with sections using Multiple Feature Select Programming).How Do I Enter Programming Mode?1) Press [ENTER]2) Enter your [INSTALLER CODE] (default: 0000 / 000000)3) Enter 3-digit [SECTION] you wish to program4) Enter required [DATA] Table 3: Decimal and Hexadecimal Programming TableValue or Action What Do I Press? What Do I See?10-Zone LED 16-Zone LED LCDValues 1 to 9 [1] to [9][1] to [9] [1] to [9] [1] to [9]A (hexa only) [0] [0 (10)] [10] 0B (hexa only) [STAY][STAY][11] BC (hexa only) [BYP][BYP][12] CD (hexa only) [MEM][MEM][13] DE (hexa only) [TBL] / [TRBL][TBL][14] EF (hexa only) [PG] / [FNC1] [PG][15] FExit Without Saving [CLEAR][ENTER] flashes [ARM1] & [STAY1] flash “SECTION [       ]”Insert Blank Digit [FORCE] Displays next digit or next sectionSave Data [ENTER] Advances to the next section
8   Reference & Installation Manual   Figure 8: Data Display Mode (LED Keypads Only)3.3 Configuring The LED KeypadDepending on the version of the keypad, two methods can be used to configure the LED keypad (1686H, 1686V and 1689):3.3.1 Configuring the 1686H, 1686V and 1689 Keypad V2.0 or higherThe keypad’s zone number, EOL definition and anti-tamper switch are programmed through the control panel’s programming mode. To do so:PLEASE NOTE: After two minutes, the keypad exits programming mode.Key [1] - Keypad Zone SelectionKey [1] determines whether the keypad’s zone is Keypad Zone 1 or Keypad Zone 2. When key [1] is OFF (not illuminated), the keypad’s zone is Keypad Zone 1. When key [1] is ON (illuminated), the keypad’s zone is Keypad Zone 2. Refer to the Table 4 on page 12 for more information.Key [1] OFF - Keypad Zone 1 (default)Key [1] ON - Keypad Zone 2Key [2] - EOL DefinitionKey [2] determines the keypad zone’s EOL definition. When key [2] is OFF (not illuminated), EOL is disabled and the keypad zone will use the on-board EOL resistor. When key [2] is ON (illuminated), EOL is enabled and the keypad zone requires that an external EOL resistor be connected (refer to Spectra 1759MG Control Panel Overview on page 3 for more details).Key [2] OFF - EOL disabledKey [2] ON - EOL enabled (default)Key [3] - On-Board Anti-TamperKey [3] enables or disables the keypad’s on-board anti-tamper switch. When key [3] is OFF (not illuminated), the anti-tamper switch is disabled. When key [3] is ON (illuminated), the anti-tamper switch is enabled.Key [3] OFF - On-board anti-tamper switch disabledKey [3] ON - On-board anti-tamper switch enabledHow Do I Configure The Keypad?1) Press [ENTER].2) Enter your [INSTALLER CODE] (default: 0000 / 000000).3) Press the [PG] (1686H/V) / [FNC1] (1689) key and hold it for 3 seconds.4) Press the desired key ([1] to [3]. See below).5) Press [ENTER] to exit programming mode.To access the Data Display Mode, press the [ENTER] key after entering a section and before entering any data. The three LEDs as indicated below will begin to flash indicating that you are in the Data Display Mode.Each time the [ENTER] key is pressed, the keypad will display the next digit in the current section and will continue through all the following sections one digit at a time without changing the programmed values. Not available for sections using the Multiple Feature Select Method. Press the [CLEAR] key at any time to exit the Data Display Mode.1686H 1686V 1689
Spectra 1759MG   9NOTE: The keypad can be ordered with or without an anti-tamper switch. If the keypad has no anti-tamper switch, key [3] will be OFF by default. If the keypad has an anti-tamper switch, key [3] will be ON by default.3.4 Programming Using A Paradox Memory Key*Copy the sections of one Spectra control panel into the Paradox Memory Key (PMC-3). Then copy the contents of the Memory Key into as many Spectra control panels as needed. Each panel is programmed in less than 3 seconds.Download to DESTINATION Control Panel1) Remove AC and battery power from the control panel.2) Place the Memory Key on the serial connector labeled KEY of the Spectra Control Panel that is to receive the contents of the Memory Key.3) Reapply AC and battery power. 4) In Installer Programming Mode, enter section [900], then press [ENTER] to acknowledge. 5) When the keypad emits a confirmation beep, remove the Memory Key.6) Enter section [750] to reprogram the modules with the information downloaded from the Paradox Memory Key.Copy to Memory Key from SOURCE Control Panel1) Remove AC and battery power from the control panel.2) Place Memory Key on the serial connector labeled KEY of the Spectra Control Panel that you want to copy. Make sure the write protect jumper of the Memory Key is on.3) Reapply AC and battery power.4) In Installer Programming Mode, enter section [902], then press [ENTER] to acknowledge.5) When the keypad emits a confirmation beep, remove the Memory Key. Remove the Memory Key’s jumper if you do not wish to accidentally overwrite its contents.Figure 9: Paradox Memory Key* Not investigated by ULJumper ON = Read from and/or write to memory key.Paradox Memory Key PMC-3Jumper OFF = Write protected (read from memory key only)Insert Paradox Memory Key onto the ‘MEMORY KEY’ connector. Partial view of Spectra 1759MG control panel
10   Reference & Installation Manual   Part 4: Access CodesThe Spectra 1759MG control panel supports the following access codes:4.1 Access Code LengthSection [127]: System OptionsOption [2] OFF = 6-Digit Access Codes Option [2] ON = 4-Digit Access Codes (default)All access codes can be set to lengths of either 4- or 6-digits. When the 4-digit option is selected, entering a 4-digit code will allow access. Using the 6-digit option, entering 6 digits is required to allow access.If the access code length is changed from four digits to six digits when access codes have already been programmed, the control panel will automatically add the last 2 digits by using the first 2 digits. For example, if the access code is 1234 and you switch to 6 digits, the code will become 123412. Be sure to verify the access codes after switching from 4-digit access codes to 6-digit codes. When switching from six digits to four digits, the control panel will simply remove the final two digits of the access code. For example, 123456 will become 1234. 4.2 Installer Code (Default: 0000 / 000000) The Installer Code is used to enter the 1759MG‘s programming mode (see page 7), which allows you to program all the features, options and commands of the control panel. The Installer Code can be 4- or 6-digits in length (see Access Code Length on page 10) where each digit can be any value from 0 to 9. The Installer Code cannot be used to program Master Code 1, Master Code 2 or user access codes. To program the Installer Code press:[ENTER] + [CURRENT INSTALLER CODE] + [281] + new 4- or 6-digit Installer Code4.3 System Master Code (Default: 1234 / 123456)The Installer Code can be used to program the System Master Code. With the System Master Code a user can use any arming method and can program any user access code, but not the User Code Options. The System Master Code can be 4 or 6 digits in length Access Code Length on page 10, where each digit can be any digit from 0 to 9. To change the System Master Code press:[ENTER] + [INSTALLER CODE] + [301] + new 4- or 6-digit System Master Code4.4 User Code OptionsSections [302] to [348]: Options [1] to [7]The User Code Options define which arming methods each user can use to arm or disarm the system. Regardless of these settings, all users can Regular arm assigned partitions and all users except those with the Arm Only option can disarm an assigned partition, regardless of how it is armed. Select one or more of the options described on the following pages for each user access code, where sections [302] to [348] represent user access codes 002 to 048. For more information please refer to Programming Access Codes on page 43.4.4.1 Partition 1 AssignmentSections [302] to [348]: User codes 002 to 048Option [1] OFF = Deny access to partition 1 Option [1] ON = User code has access to partition 1 (default)If the system is partitioned (see page 36), user codes with this option enabled can arm and disarm partition 1. If the system is not partitioned, you must assign partition 1 to the user access code. Otherwise, the user access code will be considered disabled. Installer Code: Used to program all control panel settings except user access codes.System Master Code (001): Provides full access. Arm and disarm using any method described in the User Code Options on page 10 as well as program the user access codes.Master Code 1 (002): Permanently assigned to partition 1. Same as a regular user code except it can also program access codes for user codes assigned to partition 1.Master Code 2 (003): Permanently assigned to partition 2. Same as a regular user code except it can program access codes for user codes assigned to partition 2. If the system is not partitioned Master Code 002 will be assigned to partition 1.45 User Codes (004 to 048):  Can arm and disarm as per User Code Options on page 10.
Spectra 1759MG   114.4.2 Partition 2 AssignmentSections [302] to [348]: User Codes 002 to 048Option [2] OFF = Deny access to partition 2 (default)Option [2] ON = User code has access to partition 2If the system is partitioned (see Partitioning on page 36), user codes with this option enabled can arm and disarm partition 2. If the system is not partitioned, the control panel ignores this option. 4.4.3 Bypass ProgrammingSections [302] to [348]: User Codes 002 to 048Option [3] OFF = Bypass Programming Disabled Option [3] ON = Bypass Programming Enabled (default)User codes with this option enabled can perform Bypass Programming in assigned partitions. 4.4.4 Stay ArmingSections [302] to [348]: User Codes 002 to 048Option [4] OFF = Stay Arming Disabled Option [4] ON = Stay Arming Enabled for selected User Code (default)User codes with this option enabled can Stay arm assigned partitions.4.4.5 Force ArmingSections [302] to [348]: User Codes 002 to 048Option [5] OFF = Force Arming Disabled (default)Option [5] ON = Force Arming Enabled for selected User CodeUser codes with this option enabled can Force arm assigned partitions.4.4.6 Arm OnlySections [302] to [348]: User Codes 002 to 048Option [6] OFF = Arm Only Disabled (default)Option [6] ON = Arm Only Enabled for selected User CodeThe user code with this option enabled can arm assigned partitions, but  cannot disarm any partitions. The type of arming is dependent on the other User Code Options selected. Please note that with the Arm Only option, the user can cancel a recently armed system by re-entering the access code before the end of the exit delay.4.4.7 PGM ActivationSections [302] to [348]: User Codes 002 to 048Option [7] OFF = User Code follows User Code Options and can activate a PGM (default)Option [7] ON = User Code can activate a PGM only With option [7] off, entering the access code will arm or disarm according to the programmed User Code Options as well as activate or deactivate a PGM. The appropriate PGM Activation/Deactivation Event must also be programmed (see Programmable Outputs on page 34). With option [7] on, the control panel will ignore all other User Code Options. Therefore, entering the access code will only activate or deactivate the PGM. 4.5 Lock Master CodeSection [127]: System OptionsOption [4] OFF = Lock System Master Code Disabled (default)Option [4] ON = Lock System Master Code EnabledWith this feature enabled, the control panel will lock the System Master Code (001). This means that the System Master Code cannot be deleted, but it can be changed.4.6 Duress CodeSection [127] = System OptionsOption [6] OFF = Duress Code Disabled (default)Option [6] ON = User Code 048 becomes a Duress codeWith this feature enabled, User Code 048 becomes a Duress Code. When forced to arm or disarm their system, users can enter a Duress Code (User Code 048) to arm or disarm the system which can immediately transmit a silent alert to the monitoring station, transmitting the duress report code programmed in section [196].
12   Reference & Installation Manual   Part 5: Zone ProgrammingWhen programming zones, the zone assignments are dependent on where the detection devices are connected to in the system (see Table 4). In installations that require using mostly the expansion inputs (see section 5.1), refer to Reassign Keypad Zone 2 on page 12 and Reassign Zones to Expansion Inputs on page 13. Table 4: Zone Recognition Table  5.1 What is an Expansion Input?An expansion input allows you to connect modules to the system to increase the number of zones available up to 15 zones. Each hardwired input on a zone expansion bus module or wireless transmitter can be assigned to an expansion input. The expansion inputs can be used in any combination. For example, 5 wireless transmitters and 3 hardwire inputs can be assigned to the expansion inputs. Spectra control panels cannot support more than eight expansion inputs. Refer to the appropriate module’s Instruction Sheet for details.Do not assign inputs from different modules to the same expansion input. 5.2 Reassign Keypad Zone 2Section [126]: General OptionsOption [7] OFF = Reassign Keypad Zone 2 Disabled (default)Option [7] ON = Reassign Keypad Zone 2 EnabledIn installations that require using mostly the expansion inputs, such as using wireless zones, 10-Zone LED keypads may be unable to display some of the zones. The Reassign Keypad Zone 2 feature changes the zone numbering to increase the number of expansion inputs that are displayed on 10-Zone LED keypads. Combine with the Reassign Zones to Expansion Inputs feature (see page 13) to increase the number of displayable expansion inputs. See Table 4 for Zone Recognition.When Reassign Keypad Zone 2 is enabled, the Keypad Tamper Supervision (see page 37) for Keypad Zone 2 is lost. Keypad Tamper Supervision will ONLY function on Keypad Zone 1.Option [7]: OFFOption [8]: OFF Option [7]: ONOption [8]: OFF Option [7]: OFFOption [8]: ON Option [7]: ONOption [8]: ONControl PanelInput 1 = Zone 1 Zone 1 Zone 1 Zone 1Input 2 = Zone 2 Zone 2 Zone 2 Zone 2Input 3 = Zone 3Zone 3N/A N/AInput 4 = Zone 4Zone 4N/A N/AInput 5 = Zone 5Zone 5N/A N/AKeypadZone 1 =  Zone 6 Zone 6 Zone 3 Zone 3Zone 2 =  Zone 7 N/A Zone 4 N/AExpansionInput 1 =  Zone 8 Zone 7 Zone 5 Zone 4Input 2 =  Zone 9 Zone 8 Zone 6 Zone 5Input 3 =  Zone 10 Zone 9 Zone 7 Zone 6Input 4 =  Zone 11 Zone10 Zone 8 Zone 7Input 5 =  Zone 12 Zone 11 Zone 9 Zone 8Input 6 =  Zone 13 Zone 12 Zone 10 Zone 9Input 7 =  Zone 14 Zone 13 Zone 11 Zone 10Input 8 =  Zone 15 Zone 14 Zone 12 Zone 11= not displayed on 10-Zone LED KeypadsOption [7] = Reassign Keypad Zone 2Option [8] = Reassign Zones to Expansion Inputs
Spectra 1759MG   135.3 Reassign Zones to Expansion InputsSection [126]: General OptionsOption [8] OFF = Reassign Zones to Expansion Inputs Disabled (default)Option [8] ON = Reassign Zones to Expansion Inputs EnabledIn installations that require using mostly the expansion inputs, such as using wireless zones, 10-Zone LED keypads may be unable to display some of the zones. The Reassign Zones to Expansion Inputs feature changes the zone numbering to increase the number of expansion inputs that are displayed on 10-Zone LED keypads. Combine with the Reassign Keypad Zone 2 feature (refer to Reassign Keypad Zone 2 on page 12) to increase the number of displayable expansion inputs. See Table 4 on page 12 for the Zone Recognition.5.4 Zone ProgrammingAfter connecting a hardwired detection device to one of the control panel's or zone expansion bus module’s input terminals or after setting up any wireless transmitters, define the associated zone's parameters. The zone parameters define the type of zone, the zone's partition assignment and how the control panel will react when an alarm condition occurs on that zone. These zone parameters are programmed into one section as detailed in Figure 10 on page 13. See Table 4 on page 12 for the Zone Number Recognition.Only the control panel’s on-board inputs can be defined as a fire, delayed fire or a keyswitch zone. The on-board zones are zones 01 to 05. Figure 10: Spectra Zone Programming5.5 Zone DefinitionsAs demonstrated in Figure 10, sections [001] to [015] represent zones 1 through 15 respectively, where the first digit in each of these sections represents the zone's definition. Also, refer to Zone Speed on page 17. To disable a zone, clear the contents of the section corresponding to the desired zone by pressing the [FORCE] key 3 times and pressing [ENTER]. There are 9 available Zone Definitions, which are described as follows.Zone Definitions1 - Entry Delay 12 - Entry Delay 23 - Follow4 - Instant5 - 24Hr Burglary6 - 24Hr BuzzerAdditional definitions foron-board terminals:7 - Keyswitch8 - 24Hr Fire9 - 24Hr Delayed FirePress the[ENTER] keyEnter the [INSTALLER CODE]Key in 3-digit[SECTION]Zone DefinitionFirst DigitZone PartitionAssignmentSecond DigitZone OptionsFeature SelectPress [ENTER][001] = Zone 1 [009] = Zone 9[002] = Zone 2 [010] = Zone 10[003] = Zone 3 [011] = Zone 11[004] = Zone 4 [012] = Zone 12[005] = Zone 5 [013] = Zone 13[006] = Zone 6 [014] = Zone 14[007] = Zone 7 [015] = Zone 15[008] = Zone 8Zone Partition Assignment1 - Zone Assigned to Partition 12 - Zone Assigned to Partition 23 - Zone Assigned to both PartitionsZone Options[1] Auto Zone Shutdown Enabled[2] Bypass Enabled[3] Stay Zone[4] [5] Zone Alarm TypeOFF OFF Audible Alarm (steady)OFF ON Audible Alarm (pulsed)ON OFF Silent AlarmON ON Generates only a report[6] Intellizone[7] Delay alarm transmission[8] Force ZoneKeyswitch Options[1] OFF= MaintainedON = Momentary[2] OFF = Regular ArmON = Stay ArmKeypads beep twiceSelectone Selectone
14   Reference & Installation Manual   5.5.1 Entry Delay 1 Sections [001] to [015]: Zones 1 to 15, First Digit = 1When the system is armed and a zone defined with Entry Delay 1 opens, the control panel will generate an alarm after the programmed Entry Delay 1 Timer elapses. This is to provide users with enough time to enter the protected area and disarm the system. To program the Entry Delay 1 Timer, key in the desired 3-digit delay value (000 to 255 seconds, Default = 45 seconds) into section [069]. Entry delay zones are commonly used at the entry/exit points of the protected area (i.e. front/back door, garage, etc.). Using different entry delays (see Entry Delay 2 on page 14) is useful when, for example, one entry point requires a longer delay than the other entry point or in a partitioned system where each partition may require a different entry delay.5.5.2 Entry Delay 2Sections [001] to [015]: Zones 1 to 15, First Digit = 2Entry Delay 2 zones are identical to the Entry Delay 1 zones (see section 5.5.1), except it uses a separate entry delay timer. To program the Entry Delay 2 Timer, key in the desired 3-digit delay value (000 to 255 seconds, Default = 45 seconds) into section [070].This timer is also used as the Stay Delay timer (see Stay Arming with Delay on page 22).5.5.3 Follow ZonesSections [001] to [015]: Zones 1 to 15, First Digit = 3When an armed Follow Zone opens, the control panel will immediately generate an alarm, unless an entry delay zone opens first: • If an armed Follow Zone opens after an entry delay zone opens, the control panel waits until the entry delay timer has elapsed before generating an alarm.• If an armed Follow Zone opens after more than one entry delay zone opens, the control panel will wait until the entry delay timer of the zone that opened first has elapsed.This feature is commonly used when a motion detector is protecting the area occupied by the entry point keypad. This will prevent the motion detector from causing an alarm when a user enters through the entry point to disarm the system.5.5.4 Instant ZonesSections [001] to [015]: Zones 1 to 15, First Digit = 4When an armed Instant Zone opens, the control panel immediately generates an alarm. Instant Zones are commonly used for windows, patio doors, skylights and other perimeter type zones.5.5.5 24Hr  Burglary ZonesSections [001] to [015]: Zones 1 to 15, First Digit = 5Whenever a 24Hr Burglary Zone opens, whether the system is armed or disarmed, the control panel will immediately generate an alarm.5.5.6 24Hr BuzzerSections [001] to [015]: Zones 1 to 15, First Digit = 6Whenever a 24Hr Buzzer Zone opens, whether the zone is armed or disarmed, the control panel sets off the keypad’s buzzers to indicate that the zone was breached. The control panel will report the alarm, but will not enable the bell/siren output. Enter any valid access code on the keypad to stop the buzzer. This zone definition is particularly useful when a user wishes to be notified when something such as a safe or locker within the home has been accessed (i.e. a child accessing a valuable collection).5.6 Exclusive Zone DefinitionsThe following three zone definitions can only be used for devices connected directly to the control panel’s on-board input terminals. When a zone is programmed as a keyswitch zone, the control panel will ignore all other Zone Options. When a zone is programmed as a standard fire zone or delayed fire zone, the control panel will ignore the Zone Options that may have been programmed, except Auto Zone Shutdown. Wireless devices and devices connected to the zone expansion bus modules cannot be programmed  with these definitions.5.6.1 Keyswitch Zone Sections [001] to [005]: Zones 1 to 5, First Digit = 7Connecting a keyswitch to a zone allows users to arm the system by pressing a button or by turning a switch on or off with a key. Please refer to Keyswitch Connections on page 6 and Keyswitch Options on page 17.
Spectra 1759MG   155.6.2 Standard 24Hr Fire ZoneSections [001] to [005]: Zones 1 to 5, First Digit = 8Whenever a Standard 24Hr Fire Zone opens, whether it is armed or disarmed, the control panel will generate the following:• The control panel can send the corresponding Alarm report code from sections [187] to [190]. • If a tamper/wiring fault occurs on a fire zone, the control panel can send a Fire Loop Trouble report code programmed in section [206] to the monitoring station. The keypad will display a Fire Loop Trouble in its trouble display (see page 42).• Alarms are always audible regardless of other settings. Fire alarms generate an intermittent (pulsed) bell/siren output signal as shown in Figure 11 on page 15.For information on how to connect smoke detectors to the control panel, refer to Fire Circuits on page 6.5.6.3 Delayed Fire ZoneSections [001] to [005]: Zones 1 to 5, First Digit = 9When a Delayed 24Hr Fire Zone opens, whether it is armed or disarmed, the control panel will react as shown in Figure 12 on page 15. Delayed 24Hr Fire Zones are commonly used in residential homes where a smoke detector often generates false alarms (i.e. burning bread, etc.). 5.7 Programming a Wireless Fire ZoneFire zones cannot be assigned to expansion zones. As a result, when installing a wireless smoke detector, the corresponding zone must be programmed as follows:5.8 Zone Partition AssignmentSections [001] to [015]: Zones 1 to 15The control panel provides the option of partitioning the security system into two completely independent systems. As demonstrated in Figure 10 on page 13, sections [001] to [015] represent zones 1 through 15 respectively, where the second digit in each of these sections represents the zone's partition assignment. The zone is assigned to Partition 1 if second digit = 1,  Partition 2 if second digit = 2, or both partitions is second digit = 3. For more details, refer to Partitioning on page 36. How Do I  Program a Wireless Fire Zone?1) Enter [5] in the Zone Definition to define it as a 24Hr Burglary Alarm (see page 14).2) Disable [4] and enable [5] in Zone Options to set the zone’s alarm type to a pulsed Audible Alarm (see Figure 10 on page 13).3) Disable [1] and [2] in Zone Options to disable the zone’s Auto Zone Shutdown and Bypass Enabled features (see Figure 10 on page 13).4) Change the zone’s report code from a Burglary report code (Prog. Value 11) to a Fire report code (Prog. Value 04).  If using Ademco Contact I.D., set the Contact ID Options from All Codes to Programmable (section [136] option [3] = OFF) and then enter the report code manually. See Spectra 1759MG Programming Guide for more information.BellOutputOnOffFire AlarmLatched0.5s 0.5s1.5sFigure 11: Bell Output During Fire Alarm Figure 12: Delayed 24Hr Fire Zone
16   Reference & Installation Manual   5.9 Zone OptionsAs demonstrated in Figure 10 on page 13, sections [001] to [015] represent zones 1 through 15 respectively. After entering the first two digits, select one or more of the following Zone Options by using the Multiple Feature Select Programming Method (see page 7):5.9.1 Auto Zone ShutdownSections [001] to [015] = Zones 1 to 15Option [1] OFF = Auto Zone Shutdown Disabled Option [1] ON = Auto Zone Shutdown Enabled for    selected zone (default)If, in a single armed period, the number of alarms generated by a zone with the Auto Zone Shutdown option enabled exceeds the number defined by the Auto Zone Shutdown Counter, the control panel will no longer generate an alarm for that zone. To program the Auto Zone Shutdown Counter, key in the desired limit (000=Disabled, 001 to 015, Default = 5) into section [089]. The Auto Zone Shutdown Counter resets every time the partition that is assigned to the corresponding zone is armed.5.9.2 Bypass ZonesSections [001] to [015] = Zones 1 to 15Option [2] OFF = Bypass Zone Disabled Option [2] ON = Selected Zone is Bypass Enabled (default)When a user utilizes the Bypass Programming feature (see page 44), only zones with the Bypass option enabled can be programmed as bypassed.Do not program a fire zone with the Bypass option, as the control panel will never bypass fire zones. 5.9.3 Stay ZonesSections [001] to [015]: Zones 1 to 15Option [3] OFF = Stay Zone Disabled (default)Option [3] ON = Selected Zone is Stay EnabledZones with the Stay option enabled will be bypassed when the system is Stay Armed (see page 44).Do not program a fire zone with the Stay option, as the control panel will never bypass fire zones when Stay arming. 5.9.4 Alarm TypesSections [001] to [015]: Zones 1 to 15[4] OFF / [5] OFF: Audible Steady (default) When the conditions for an alarm have been met, the control panel can transmit the appropriate Zone Alarm report code (see page 28) and provides a steady output for any bells or sirens connected to the control panel’s bell output. [4] OFF / [5] ON: Audible Pulsed AlarmWhen the conditions for an alarm have been met, the control panel can transmit the appropriate Zone Alarm report code (see page 28) and provides a pulsed output (see Figure 11 on page 15) for any bells or sirens connected to the control panel’s bell output. [4] ON / [5] OFF: Silent Alarm When the conditions for an alarm are met, the control panel can transmit the appropriate Zone Alarm report code (see page 28) and will not activate the control panel’s bell output. The appropriate ARM or STATUS LED on the keypads will flash to indicate an alarm and the user will still have to disarm the system.[4] ON / [5] ON: Report Only When the conditions for an alarm have been met, the control panel can transmit the appropriate Zone Alarm report code (see page 28). The system will not have to be disarmed.5.9.5 IntellizoneSections [001] to [015]: Zones 1 to 15Option [6] OFF = Intellizone Disabled (default)Option [6] ON = Intellizone Enabled for Selected ZoneThis feature reduces the possibility of false alarms. When a zone with the Intellizone option opens, the  panel does not immediately generate an alarm. First it triggers the Intellizone Delay Timer. To program the Intellizone Delay Timer, key in the desired 3-digit value (010 to 255 seconds, Default = 48 seconds) into section [084]. If any of the following conditions occur during this period, the panel will generate an alarm:• During the Intellizone Delay, a second zone has caused an alarm.• During the Intellizone Delay, the zone in alarm has restored (closed) and re-occurred (opened).• The zone in alarm remains open for the entire Intellizone Delay.
Spectra 1759MG   175.9.6 Delay Before Alarm Report Code Transmission Sections [001] to [015]: Zones 1 to 15Option [7] OFF = Delay Alarm Transmission Disabled (default)Option [7] ON = Delay Alarm Transmission Enabled for Selected ZoneWhen an alarm condition occurs on a zone with this option enabled, the control panel enables the bell/siren output, but does not report the alarm to the monitoring station until the end of the Alarm Before Transmission Delay. To program the Alarm Transmission Delay, key in the desired 3-digit delay value (000 = Disabled, 001 to 255 seconds) into section [080]. During this period, disarming the system disables the bell/siren output and cancels the report code transmission. This feature is commonly used with entry delay zones to reduce false alarms created by new users who may not disarm the system in time.5.9.7 Force ZonesSections [001] to [015]: Zones 1 to 15Option [8] OFF = Force Zone Disabled (default)Option [8] ON = Selected Zone is Force EnabledAny open Force Zones at the time of arming will be considered deactivated by the control panel (see page 44). If during this period a deactivated zone is closed, the control panel will revert that zone to active status. Consequently, the control panel will generate an alarm if the zone is breached.Do not program a fire zone with the Force option, as the control panel will never bypass fire zones when Force arming. 5.9.8 Keyswitch OptionsSections [001] to [005]: Option [1] and [2]When an on-board zone is programmed as a keyswitch zone (see page 14), the control panel will ignore any other Zone Option. The keyswitch can be programmed as a Maintained or Momentary Keyswitch and to Regular or Stay arm (see page 44). A Maintained Keyswitch will arm the system when it is set to the ON position and will disarm when set to the OFF position. To arm with a Momentary Keyswitch, set the keyswitch to the ON position then turn it back to the OFF position. Repeating this sequence will disarm the system. Program the keyswitch with the following:5.10 Zone SpeedSections [050] to [064]: Zones 1 to 15 001 to 255 X 10ms, Default = 600msThe Zone Speed defines how quickly the control panel will respond to an open zone. The control panel will not display an open zone on the keypad or generate an alarm until the programmed Zone Speed has elapsed. All other zone definitions and options do not come into effect until the Zone Speed has elapsed. This feature prevents any momentary glitches from causing an alarm or unnecessary reporting. 5.11 EOL ZonesSection [132]: Zone OptionsOption [4] OFF = Zones do not use EOL resistors (default)Option [4] ON = Zones require EOL resistorsIf all detection devices connected to the control panel have input terminals that require 1KΩ end of line resistors, enable option [4] in section [132]. For details on using EOL resistors, refer to Single Zone Inputs on page 5.Option [1] OFF = Maintained (default) Option [2] OFF  = Regular Arming (default)Option [1] ON = Momentary Option [2] ON  = Stay Arming
18   Reference & Installation Manual   Part 6: Wireless FeaturesThe Spectra 1759MG allows for the addition of up to eight fully supervised Magellan wireless transmitters, and up to eight programmable remote controls. To program a wireless fire zone, refer to Programming a Wireless Fire Zone on page 15.6.1 Wireless Transmitter ProgrammingThe programming of the wireless transmitters (detectors and door contacts) is accomplished in two steps:1. Assign the wireless transmitter to the Spectra 1759MG.2. Program the zones.6.1.1 Assigning Wireless Transmitters to the ReceiverSections [601] to [608]Sections [601] to [608] represent expansion inputs 1 to 8 respectively. For example, section [601] is assigned to expansion input 1, section [602] is assigned to expansion input 2, etc. (refer to Table 5). Each Expansion Input represents a specific zone in the Spectra 1759MG system (see Table 4 on page 12).Do not assign detection devices from different modules to the same expansion input. For example, do not assign a wireless transmitter to section [601] and then connect a detection device to input Z1 of the APR3-ZX8. The serial number is located on the inside of the transmitter or you can use the Serial Number Display (see page 19) to determine its serial number.The transmitters must be activated once having been assigned to the Spectra 1759MG. To activate a transmitter, insert the batteries and close the cover. To ensure proper synchronization between the control panel and the transmitter, open and close the zone corresponding to the transmitter.6.1.2 Deleting Assigned Wireless TransmittersSections [601] to [608]6.1.3 Programming the ZonesThe zones allocated to the wireless transmitters must be programmed. Refer to Zone Programming on page 12 for more information.Table 5: Sections and Expansion InputsSection # 6-digit Serial Number Expansion Input[601] ___/___/___/___/___/___ Input 1[602] ___/___/___/___/___/___ Input 2[603] ___/___/___/___/___/___ Input 3[604] ___/___/___/___/___/___ Input 4[605] ___/___/___/___/___/___ Input 5[606] ___/___/___/___/___/___ Input 6[607] ___/___/___/___/___/___ Input 7[608]  ___/___/___/___/___/___ Input 8How Do I Assign Wireless Transmitters to the Spectra 1759MG?1) Press the [ENTER] key.2) Enter your [INSTALLER CODE].3) Enter the desired [SECTION NUMBER] (from sections [601] to [608]).4) Enter the 6-digit [SERIAL NUMBER] of the wireless transmitter.How Do I Delete Assigned Wireless Transmitters?1) Press the [ENTER] key.2) Enter your [INSTALLER CODE].3) Enter the desired [SECTION NUMBER] (from sections [601] to [608]).4) Press the [0] key six times to clear the serial number.
Spectra 1759MG   196.2 Viewing the Wireless Transmitter Signal StrengthSections [631] to [638]Once wireless transmitters have been installed and assigned to the Spectra 1759MG, the signal strength of each transmitter can be verified in sections [631] to [638]. Each section represents the signal strength viewer for a specific device. For example, section [631] is the viewer for the device in section [601] and section [638] is the viewer for the device in section [608]. Please note that this feature only works with wireless transmitters assigned to an Expansion Input (zone) as described in Assigning Wireless Transmitters to the Receiver on page 18. A reading of 1 is the weakest and a reading of 8 is the strongest. An average reading of 3 or higher is acceptable. Sometimes moving the transmitter or control panel by a small amount will greatly increase the signal reception.After entering the desired section, ignore the first reading as it will not be accurate.You can also use a beep sequence feature to verify a transmitter’s signal strength. When you press a transmitter’s anti-tamper switch, beep tones emanating from all the keypads connected to the communication bus will advise you of the transmitter’s signal strength.This feature cannot be used with any remote controls assigned to the control panel.6.3 Serial Number DisplaySection [630]This feature will display the serial number of any wireless transmitter on any Spectra keypad.6.4 Supervision OptionsThe Supervision Options cannot be used with any remote controls assigned to the control panel.6.4.1 Check-in SupervisionSection [610]: Supervision OptionsOption [1] OFF = Check-in Supervision disabled (default)Option [1] ON = Check-in Supervision enabledHow Do I View a Wireless Transmitter’s Signal Strength?1) Press the [ENTER] key.2) Enter your [INSTALLER CODE].3) Enter the desired [SECTION NUMBER] (from sections [631] to [638]).4) Press the transmitter’s anti-tamper switch or open the corresponding zone.5) On an LED keypad: The keypad will illuminate numbers 1 to 8.On an LCD keypad: The keypad will display numbers from 1 to 8 on the screen. For example, the LCD screen below shows a signal strength reading of 5.How Do I Attain a Wireless Transmitter’s Signal Strength using the Beep Sequence?1) Press the [ENTER] key.2) Enter your [INSTALLER CODE].3) Enter the desired [SECTION NUMBER] (from sections [631] to [638]).4) Press the transmitter’s anti-tamper switch or open the corresponding zone.5) Listen for the beep tones:If the signal strength is less than 3 = One beepIf the signal strength is between 3 and 6 = Two beepsIf the signal strength is greater than 6 = Three beepsHow Do I View a Transmitter’s Serial Number?1) Press the [ENTER] key.2) Enter your [INSTALLER CODE].3) Enter the section [630].4) Press the [0] key six times to clear the serial number.5) On an LED Keypad: The serial number digits will appear one at a time by illuminating the corresponding LED light. To view the next digit, press the [ENTER] key.On an LCD Keypad: The first three digits of the serial number will appear. Press the [ENTER] key three times to view the next three digits.
20   Reference & Installation Manual   Option [1] enables the Check-in Supervision feature. The Spectra 1759MG waits for each of its assigned wireless transmitters to send a status signal within a specified time period (as programmed in Check-in Supervision Timer Settings on page 20) to confirm their presence and functionality. If a device has not sent a signal within that time period, the Spectra 1759MG can generate a trouble, an alarm, and/or transmit a report code to the monitoring station (refer to Wireless Transmitter Supervision Options on page 39).6.4.2 Check-in Supervision Timer SettingsSection [610]: Supervision OptionsOption [2] OFF = Check-in supervision interval is every 24 hours (default)Option [2] ON = Check-in supervision interval is every 80 minutesOption [2] defines the time period that the control panel will expect a check-in status signal from its assigned wireless transmitters. For example, if the timer is set to 80 minutes (option [2] = ON), the control panel will expect a check-in status signal to be sent from its assigned wireless transmitters every 80 minutes. If the Spectra 1759MG does not receive a signal from one of its wireless transmitters within the period of time defined here, it can then generate a trouble, an alarm, and/or can transmit a report code to the monitoring station (refer to Wireless Transmitter Supervision Options on page 39). Refer to Check-in Supervision on page 19 for instructions on enabling check-in supervision.6.4.3 Tamper SupervisionSection [610]: Supervision OptionsOption [8] OFF = Tamper Supervision disabled (default)Option [8] ON = Tamper Supervision enabled When the control panel detects a tamper or wire fault on a zone or on an expansion module, the control panel can generate an alarm and/or trouble, unless the Tamper Supervision is disabled.6.4.4 Low Battery SupervisionWhen the battery voltage of a wireless transmitter (motion detector or door contact) drops below a certain value, the Spectra 1759MG will send a low battery report code to the monitoring station, and a trouble will appear in the keypad’s trouble display.Section [129] option [6] must be enabled in order for Low Battery Supervision to work. For more information, refer to Wireless Transmitter Low Battery Supervision on page 39.6.5 Remote Control ProgrammingThe Spectra 1759MG accepts up to eight fully programmable remote controls. Programming the remote controls is accomplished in three steps:1) Assign the remote controls to the Spectra 1759MG control panel.2) Assign the remote controls to user access codes. 3) Program the buttons on the remote controls.6.5.1 Assigning a Remote Control to the Spectra 1759MGSections [731] to [738]: Remote Controls 1 to 8 respectivelyRemote controls are assigned to the module using the Automatic Learning method.If you are having trouble assigning the remote control, the environment may be too noisy. Therefore, we recommend that you assign the remote controls before installing the transmitters.6.5.2 Deleting Assigned Remote ControlsSections [731] to [738]: Remote Controls 1 to 8 respectivelyHow Do I Assign a Remote Control to the Spectra 1759MG?1) Press the [ENTER] key.2) Enter your [INSTALLER CODE].3) Enter the desired [SECTION NUMBER] (from sections [731] to [738]).4)Press and hold any button on the remote control until the confirmation beep sounds (“Beep-Beep-Beep-Beep-Beep”).How Do I Delete a Remote Control?1) Press the [ENTER] key.2) Enter your [INSTALLER CODE].3) Enter the desired [SECTION NUMBER] (from sections [731] to [738]).4) Press the [FORCE] button.
Spectra 1759MG   216.5.3 Assigning Remote Controls to User Access CodesSections [701] to [708]: Remote Controls 1 to 8 respectivelyEach remote control must be assigned to a user access code. All user access codes are given a user number from 001 to 048. Enter the desired user number in a section from [701] to [708] that represent the remote control assigned in sections [731] to [738] (refer to Assigning a Remote Control to the Spectra 1759MG on page 20). For example, the remote control assigned in section [731] will be assigned to the user access code designated in section [701].6.5.4 Programming the Remote Control ButtonsSections [711] to [718]: Remote Controls 1 to 8 respectivelyEach remote control can be programmed to perform up to 5 different actions. Each digit in sections [711] to [718] represents a button or combination of buttons (refer to Table 6 on page 21). When a user arms or disarms using the remote control, the control panel will arm or disarm all the areas assigned to the user access code (see Assigning Remote Controls to User Access Codes on page 21). Sections [711] to [718] represent the remote controls assigned to sections [731] to [738] (refer to Assigning a Remote Control to the Spectra 1759MG on page 20). For example, the buttons for the remote control assigned in section [731] will be programmed in section [711].The user code assigned to the remote control (refer to Assigning Remote Controls to User Access Codes on page 21) must have the same User Options enabled. For example, if you enable the Force Arming button option, you must enable the appropriate Force Arming user option. Also, if you enable any Panic button options, you must enable the Panic options in the control panel (refer to Keypad Panic Options on page 26).How Do I Assign a Remote Control to a User Access Code?1) Press the [ENTER] key.2) Enter your [INSTALLER CODE].3) Enter the desired [SECTION NUMBER] (from sections [701] to [708]).4) Enter the [USER NUMBER] to be assigned to the remote control (001 to 048).How Do I Program the Remote Control’s Buttons?1) Press the [ENTER] key.2) Enter your [INSTALLER CODE].3) Enter the desired [SECTION NUMBER] (from sections [711] to [718]).4) Enter the [HEXADECIMAL VALUE] (0 to D) of the desired button option from Table 7 in the appropriate space (refer to Table 6). If you do not wish to program all the buttons or button combinations, simply press the [ENTER]  key at any time to save and exit.Table 6: Remote Control Button ProgrammingRC# Section RC ButtonsDefault: ( 1  5  0  0  0  0  0  0 )1 [711]   _____/_____/_____/_____/______/_____/_____/______        2 [712]   _____/_____/_____/_____/______/_____/_____/______        3 [713]   _____/_____/_____/_____/______/_____/_____/______        4 [714]   _____/_____/_____/_____/______/_____/_____/______        5 [715]   _____/_____/_____/_____/______/_____/_____/______        6 [716]   _____/_____/_____/_____/______/_____/_____/______        7 [717]   _____/_____/_____/_____/______/_____/_____/______        8 [718]   _____/_____/_____/_____/______/_____/_____/______        ++ + +++ + +++ + +++ + +++ + +++ + +++ + +++ + += These button combinations are not available with the MG-REM1 or MG-RAC1 remote controls and cannot be programmed.
22   Reference & Installation Manual        *  Event Group #07, #08 and #09 (Button Pressed on Remote) of the Spectra 1759MG PGM Table. For the PGM Table, please refer to the Spectra 1759MG Programming Guide (1759MG-EP).† The Panic feature must be enabled in the control panel.Part 7: Arming and Disarming Options7.1 Switch To Stay ArmingSection [133]: Partition 1, Section [134] = Partition 2 Option [4] OFF = Switch to Stay Arming Disabled (default)Option [4] ON = Switch to Stay Arming EnabledIf a user Regular arms a partition, but does not exit through (open and close) an entry delay zone during the exit delay, the control panel can be programmed to switch from Regular arming to Stay arming.7.2 Stay Arming with Delay Section [133]: Partition 1, Section [134] = Partition 2 Option [5] OFF = Stay Arming with Delay Disabled (default)Option [5] ON = Stay Arming with Delay EnabledIf a partition is Stay armed when this feature is enabled, all the zones in the partition, except 24Hr zones and Stay zones, are associated with the Stay Delay. Therefore, the control panel will not generate an alarm if a zone is breached until the Stay Delay has elapsed. This feature prevents false alarms by allowing users enough time to disarm their system if a zone is accidentally triggered. For example, if a user opens an armed window or crosses an armed detector on the way to the kitchen in the middle of the night, the user will have enough time to disarm the system before the alarm is generated. Each partition’s Stay Delay follows the value programmed in Entry Delay Timer 2 in section [070].Table 7: Button Options[FORCE] = Button Disabled [7] = Regular Arm and Disarm[1] = Regular Arm [8] = Generate a Panic 1† Alarm (Police)[2] = Stay Arm [9] = Generate a Panic 2† Alarm (Medical)[3] = Instant Arm [A] = Generate a Panic 3† Alarm (Fire)[4] = Force Arm [B] = Activates any PGMs that have Event Group #07* as their Activation Event[5] = Disarm [C] = Activates any PGMs that have Event Group #08* as their Activation Event[6] = Disarm when there is no alarm [D] = Activates any PGMs that have Event Group #09* as their Activation EventFigure 13: Remote Control Button IdentificationFour button Remote Control
Spectra 1759MG   237.3 Regular Arming Switches to Force Arming (Not to be used with UL Installations)Section [131]: Arming/Disarming OptionsOption [2] OFF = Regular Arming Switches to Force Arming Disabled (default)Option [2] ON = Regular Arming Switches to Force Arming EnabledWith this feature enabled, the control panel will always Force arm instead of Regular arm when a valid user access code with the Force Arming Option is entered. In installations where the user must always Force arm when leaving the protected area, this feature allows users to Force arm without pressing the [FORCE] key before entering their user access code. Force arming cannot be done using a keyswitch. Force arming is not supported by keyswitches.7.4 Restrict Arming on Battery FailSection [130]: Arming/Disarming OptionsOption [5] OFF = Permit arming on battery failure (default)Option [5] ON = Restrict arming on battery failureIf this option is enabled, the control panel will not arm the system if the control panel detects that the backup battery is disconnected, that its fuse is blown, or that the battery voltage drops to less than 10.5V. The control panel will not arm the system until all battery trouble conditions are rectified. 7.5 Restrict Arming on Tamper FailureSection [130]: Arming/Disarming OptionsOption [6] OFF = Permit arming on tamper failure (default)Option [6] ON = Restrict arming on tamper failureIf this option is enabled, the control panel will not arm the system if the control panel detects a tamper trouble on one or more zones. The control panel will not arm the system until all tamper trouble conditions are rectified. This feature will not function if the Tamper Recognition Options (see page 25) are disabled or whenever the tampered zone is bypassed and the Tamper Bypass Options (see page 26) have been enabled.7.6 Timed Auto-ArmingSection [133] = Partition 1, [134] = Partition 2 Option [1] OFF = Timed Auto-Arming Disabled (default)Option [1] ON = Timed Auto-Arming EnabledEach partition can be programmed to arm every day at the time specified by the Auto-arm Timer. The Auto-arming Options (see page 24) determine the partition's arming method. Any open zones detected when a partition is Auto-Armed will be bypassed regardless of their definition (except 24Hr zones). The control panel will enter a 60-second exit delay period before arming the system. At this point, Auto-arming can be cancelled by entering a valid access code. Once the partition has successfully armed, the control panel can transmit the Timed Auto-arming report code programmed in section [172]. Example: To automatically arm partition 2 everyday at 6:15PM, enable Timed Auto-arming for partition 2 by turning on option [1] in section [134]. Then key in 18:15 into section [112].7.6.1 Auto-Arm TimerSection [111] = Partition 1, [112] = Partition 2 Select the section corresponding to the desired partition and program the time (use the 24-hour clock i.e. 6:30PM = 18:30) that you wish the control panel to attempt to arm the selected partition and/or send the Late to Close report code.  7.7 No Movement Auto-Arming Section [133] = Partition 1, [134] = Partition 2 Option [2] OFF = No Movement Auto-Arming Disabled (default)Option [2] ON = No Movement Auto-Arming EnabledIf no movement occurs in a partition's protected area for the period specified by the No Movement Timer (see page 24), the control panel can automatically arm that partition. The Auto-arming Option described on page 24 of this manual determines the partition's arming method. Any open zones detected when a partition is Auto-armed will be bypassed regardless of their definition (except 24Hr zones). Upon arming, the control panel will transmit the No Movement report code if programmed in section [172]. Regardless of whether the system was successfully armed or not, the control panel will always transmit the No Movement report code if programmed in section [172]. If No Movement Auto-arming is disabled, the control panel will still send the No Movement report code at the time specified by the No Movement Timer. Example: To arm partition 1 whenever there is no movement for a period of 4 hours, enable No Movement Auto-arming for partition 1 by turning on the [2] Option in section [133]. Then in section [075] enter 016 (16x15min = 240min = 4 hours).
24   Reference & Installation Manual   7.7.1 No Movement TimerSection [075] = Partition 1, [076] = Partition 2 001 to 255 x15min, Default = Disabled Select the section corresponding to the desired partition and program the interval of time without movement you wish the control panel to wait before arming and/or sending the No Movement report code. If No Movement Auto-arming is disabled, the control panel can still send the No Movement report code when no movement has been detected for the period specified by the No Movement Timer. 7.8 Auto-Arming Options (Not to be used with UL installations)Section [133] = Partition 1, [134] = Partition 2 Option [3] OFF = Regular Arming (default)Option [3] ON = Stay Arming When using Timed Auto-arming or No Movement Auto-arming (see pages 23 and 23), the control panel can Regular or Stay arm (see page 44) the selected partition. 7.9 One-Touch Arming (Not to be used with UL installations)Section [130]: Options [1] to [4]Option [1] ON = Press & hold the [ENTER] key for One-touch Regular Arming.Option [2] ON = Press & hold the [STAY] key for One-touch Stay Arming. Option [3] ON = Press & hold the [FORCE] key for One-touch Force Arming.Option [4] ON = Press & hold the [BYP] key for One-touch Bypass Programming.The One-touch arming features allow users to arm the system without having to enter any access codes. To arm the system, press and hold the appropriate key (see above) for approximately 2 seconds. If the system is partitioned (see page 36), you must also press the key corresponding to the partition you wish to arm. For more information on the different arming methods, please refer to page 44.7.10 Exit DelaySection [071] = Partition 1, [072] = Partition 2 001 to 255 seconds, Default = 30 seconds, Maximum 60 seconds for UL Listed systems After entering the required arming sequence (i.e. user access code, etc.), the exit delay parameter determines the amount of time a user has to leave the protected area before the control panel arms the partition. The exit delay applies to all zones in the selected partition. When enabled, the keypad will beep once every second during the exit delay and will beep rapidly during the final 10 seconds of the exit delay. 7.10.1 Beep On Exit DelaySection [130]: Arming/Disarming OptionsOption [8] OFF = Beep on Exit Delay Disabled Option [8] ON = Beep on Exit Delay Enabled (default)7.11 Bell Squawk On Arm/Disarm with KeypadSection [130]: Arming/Disarming OptionsOption [7] OFF = Bell Squawk on Arm/Disarm Disabled (default)Option [7] ON = Bell Squawk on Arm/Disarm EnabledWhen this feature is enabled, the bell or siren will squawk once upon arming and twice upon disarming.7.12 Bell Squawk On Arm/Disarm with Remote ControlSection [131]: Arming/Disarming OptionsOption [3] OFF = Bell Squawk on Arm/Disarm with Remote Control Disabled (default)Option [3] ON = Bell Squawk on Arm/Disarm with Remote Control EnabledWhen this feature is enabled, the bell or siren will squawk once upon arming with a remote control and twice upon disarming with a remote control. Must be enabled for UL installations.7.13 No Exit Delay When Arming with Remote ControlSection [131]: Arming/Disarming OptionsOption [4] OFF = Provides Exit Delay When Arming with a Remote Control (default)Option [4] ON = No Exit Delay When Arming with a Remote ControlWhen the option is enabled, the panel cancels the exit delay (arms instantly) when a partition is armed with a remote control. When disabled, the exit delay timer will start when a partition is armed with a remote control.
Spectra 1759MG   257.14 No Exit Delay Beeps and No Bell Squawk When Stay ArmingSection [131]: Arming/Disarming OptionsOption [5] OFF = No Exit Delay Beeps and No Bell Squawk When Stay Arming Disabled (default)Option [5] ON = No Exit Delay Beeps and No Bell Squawk When Stay Arming EnabledWith this feature enabled, the control panel will prevent the bell or siren from squawking and the keypads from beeping during the exit delay, whenever a partition is Stay armed. Part 8:  Alarm Options8.1 Bell Cut-Off TimerSection [073] = Partition 1, [074] = Partition 2 000 = Disabled, 001 to 255 minutes, Default = 4 minutes, 5 minutes minimum for ULC installationsAfter an audible alarm, the bell or siren will stop upon disarming of the partition or when the Bell Cut-Off Timer has elapsed, whichever comes first. 8.2 Recycle AlarmAfter the Bell Cut-Off Timer and the Recycle Delay have elapsed, the control panel will re-verify the zone status. If there are any open zones, the control panel will generate another alarm. In one armed period, the control panel will repeat this sequence the number of times defined by the Recycle Counter. 8.2.1 Recycle Alarm DelaySection [090] 000 = disabled, 001 to 255 minutes, Default = DisabledThe Recycle Delay determines the amount of time after Bell Cut-Off that the control panel will wait before re-verifying zone status.  8.2.2 Recycle CounterSection [091] 000 = disabled, 001 to 255, Default = Disabled The Recycle Counter determines the number of times the control panel will re-verify the zone status after Bell Cut-Off in one armed period. 8.3 Tamper Recognition Section [132]: Zone Options[1] OFF / [2] OFF: Tamper Recognition Disabled (default)If the system is armed or disarmed, the control panel will display the zone as open in the keypad display, but will not generate an alarm. This option is not permitted on UL systems.[1] OFF / [2] ON: Trouble OnlyIf the system is armed and a tamper wiring failure occurs on a zone, the control panel will follow the zone's Alarm Types setting (see page 16). If the system is disarmed and a tamper wiring failure occurs on a zone, a Tamper/Zone Wiring Failure will appear in the keypad’s trouble display (see page 42) and the control panel will transmit the appropriate Zone Tamper report code (see page 29).    [1] ON / [2] OFF: Silent AlarmIf the system is armed and a tamper wiring failure occurs on a zone, the control panel will follow the zone's Alarm Types setting (see page 16). In a disarmed system, it functions the same as the Trouble Only setting, but it will also generate a silent alarm. A silent alarm will not trigger any bells or sirens, but the system will have to be disarmed.[1] ON / [2] ON: Audible AlarmIn an armed system and a tamper wiring failure occurs on a zone, the control panel will follow the zone's Alarm Types setting (see page 16). In a disarmed system, it functions the same as Trouble Only setting, except it will also generate an audible alarm.
26   Reference & Installation Manual   8.3.1 Tamper Bypass OptionsSection [132]: Zone OptionsOption [3] OFF = Will generate a tamper if detected on a bypassed zone (default)Option [3] ON = Tampers on bypassed zones will be ignoredWith option [3] on, the Tamper Recognition feature follows the zone bypass definition. This means the control panel will ignore any tampers detected on a bypassed zone. With option [3] off, Tamper Recognition ignores the bypass definition. This means the control panel will generate an incident as per Tamper Recognition settings if a tamper or wire fault occurs on a bypassed zone. 8.4 Keypad Panic OptionsSection [128]: General OptionsOption [1] OFF = Emergency Panic Disabled (default)Option [1] ON  = Emergency Panic EnabledPressing the [1] and [3] keys simultaneously on the keypad for 2 seconds will generate a silent or audible alarm as defined by option [4].Option [2] OFF = Auxiliary Panic Disabled (default)Option [2] ON  = Auxiliary Panic EnabledPressing the [4] and [6] keys simultaneously on the keypad for 2 seconds will generate a silent or audible alarm as defined by option [5].Option [3] OFF = Fire Panic Disabled (default)Option [3] ON  = Fire Panic EnabledPressing the [7] and [9] keys simultaneously on the keypad for 2 seconds will generate a silent or audible alarm as defined by option [6].Option [4] OFF = Emergency Panic is Silent (default)Option [4] ON  = Emergency Panic is AudibleOption [5] OFF = Auxiliary Panic is Silent (default)Option [5] ON  = Auxiliary Panic is AudibleOption [6] OFF = Fire Panic is Silent (default)Option [6] ON  = Fire Panic is PulsedSilent alarm:The control panel emits a confirmation beep and transmits the appropriate Panic report code if programmed in section [195]. The control panel will not enable the keypad buzzers or the control panel’s BELL output (no audible alarm). Audible alarm:Same as silent alarm, except the keypad buzzers and the BELL output will activate until a user cancels the alarm (disarms) with a valid user access code or when the Bell Cut-Off Timer elapses (see page 25).Fire (pulsed) alarm:Same as audible operation, except that the BELL output will be pulsed as shown in Figure 11 on page 15.Whether the system is partitioned or not, the control panel will report all panic alarms to partition 1.8.5 Panic Lockout TimerSection [094]When a panic alarm is activated, the control panel can ignore the disarm signal from a remote control for a specified period. This prevents an aggressor from disarming the system by remote control during a panic situation. In section [094] enter a 3-digit value (000 to 255, 000 = disabled) representing the number of seconds that the remote controls will be locked out of the system.
Spectra 1759MG   27Part 9: Reporting and Dialer settingsThe following section explains all the features and options that must be programmed in order for your security system to properly report system events to a monitoring station. When an event (e.g. zone in alarm) occurs in the system, the control panel verifies if a report code was programmed in the section corresponding to the event (except Ademco Contact ID “All Codes”). If a report code was programmed, the control panel will dial the monitoring station telephone number defined by the Event Call Direction feature. When the monitoring station answers, the control panel will transmit the System Account Code, followed by the programmed report code.Figure 14: Event ReportingReporting/DialerOption [3] - Section [135]Partition Account NumbersPartition Account Number 13 or 4 digits (0-F) in section [143]Partition Account Number 23 or 4 digits (0-F) in section [144]Monitoring Station Telephone Numbers 1 & 2Defines which monitoring station telephone numbers each group of events will report to.Section [137]Option [1] ON = Call Telephone #1 for Arm/Disarm Report CodesOption [2] ON = Call Telephone #2 for Arm/Disarm Report CodesOption [3] ON = Call Telephone #1 for Alarm/Restore Report CodesOption [4] ON = Call Telephone #2 for Alarm/Restore Report CodesOption [5] ON = Call Telephone #1 for Tamper/Restore Report CodesOption [6] ON = Call Telephone #2 for Tamper/Restore Report CodesSection [138]Option [1] ON = Call Telephone #1 for Trouble/Restore Report CodesOption [2] ON = Call Telephone #2 for Trouble/Restore Report CodesOption [3] ON = Call Telephone #1 for Special System Report CodesOption [4] ON = Call Telephone #2 for Special System Report CodesMonitoring Station Telephone Numbers 1 & 2Sections [151] & [152]Back-up NumberSection [153]Related FeaturesDelay Before Alarm TransmissionSection [080]Pager Format Delay TransmissionSection [083]Recent Closing DelaySection [085]Power Failure Report DelaySection [086]Auto Test ReportSections [087] & [110]Report Disarm OptionsOption [1] - Section [131]Report Zone Restore OptionsOption [6] - Section [132]Alternate DialOption [4] - Section [136]Maximum Dialing AttemptsSection [081]Delay between Dialing AttemptsSection [136]Reporting FormatsSection [140]1st digit = CSTN#12nd digit = CSTN#2Program 1 or 2-digit (1 - FF) report codes into sections [160] to [213] where each section represents up to four events in the system.Program the 2-digit report codes corresponding to the Contact I.D. Table into sections [160] to [213] where each section represents up to four events in the system. Program FF to use the default Contact ID report code.The control panel automatically generates all report codes. You do not have to program any report codes.DTMF(Tone)[5] = Ademco Contact ID[6] = Pager[4] = Ademco Express“Programmable”Option [3] OFF - Section [136]“Programmable”Option [3] ON - Section [136][2] = Silent Knight FastPulse[1] = Ademco Slow[3] = SescoaPartition 1Partition 2
28   Reference & Installation Manual   9.1 Reporting/Dialer (Enable/Disable)Section [135]: Dialer OptionsOption [3] OFF = Reporting/Dialer Disabled (default)Option [3] ON = Reporting/Dialer Enabled9.2 Report Codes A report code is a 1- or 2-digit hexadecimal value consisting of digits from 1 to F. Each section from [160] to [213] represents a set of up to four specific events and each of these events can be programmed with a separate 1- or 2-digit report code. Only the Ademco Slow, Silent Knight, Sescoa and Pager Formats support 1-digit report codes. To program a 1-digit report code, press the [FORCE] key followed by the desired hexadecimal digit or vice versa. When a specific event occurs, the control panel will attempt to transmit the programmed report code to the monitoring station. The method of report code transmission is defined by the Reporting Formats (see page 30) and the Event Call Direction (see page 32). These two items define how and where the report codes are transmitted. If you are using the Ademco Contact ID “All Codes” format, sections [160] to [213] do not have to be programmed. For more information, refer to Reporting Formats on page 30. The following sub-sections provide a brief description of the events that the control panel can report.9.2.1 Arming Report CodesSections [160] to [171]A report code can be programmed for each of the 48 user access codes. When using an access code to arm a partition, the control panel can send the appropriate report code to the monitoring station, identifying which access code was used to arm the partition.9.2.2 Special Arming Report CodesSections [172] and [173]Whenever the system is armed using one of the special arming features listed below, the control panel can send the appropriate report code to the monitoring station identifying how the system was armed.Section [172]•Timed Auto-Arming: A partition has armed itself at the programmed time (see page 23). •Late to Close: Reports every day at the time specified by the Auto-arm Timer (see page 23). •No Movement: A partition has armed itself after the programmed period without movement (see No Movement Auto-Arming on page 23).•Partial Arming: A partition was Stay, Instant or Force armed or armed with Bypassed zones.Section [173]•One-Touch Arming: A partition was armed using a One-touch arming feature (see page 24).•Remote Arming: A partition was armed using the Winload software. •Keyswitch Arming: A partition was armed using a keyswitch (see page 14).•Closing Delinquency: Partition 1 was not armed within a set period of time (see page 33).9.2.3 Disarming Report CodesSections [174] to [185]A report code can be programmed for each of the 48 user access codes. Whenever an access code is used to disarm an armed partition or a partition in alarm, the control panel can send the appropriate report code to the monitoring station, identifying which access code was used to disarm the partition. The Disarming and the Special Disarming report codes can be transmitted every time a partition is disarmed or only when a partition is disarmed after an alarm (see Disarm Reporting Options on page 33).9.2.4 Special Disarming Report CodesSection [186]Whenever using one of the special disarming features, the control panel can send the report code to the monitoring station, identifying how the system was disarmed.•Cancel Auto-Arm: A partition is disarmed during the Timed Auto-arm's 60-second exit delay (see Timed Auto-Arming on page 23). Only reports if Disarming Reporting Options (see page 33) are set to always report disarming. •Remote Disarm: System is disarmed using   the   Winload software.                                                                                                                        •Keyswitch Disarming: System disarmed using a keyswitch (see page 14).• Future use9.2.5 Zone Alarm Report CodesSections [187] to [190]A report code can be programmed for each of the 15 available zones. Whenever a zone generates an alarm, the control panel can send the appropriate report code to the monitoring station, identifying which zone generated an alarm.
Spectra 1759MG   299.2.6 Zone Alarm Restore Report CodesSections [191] to [194]A report code can be programmed for each of the 15 available zones. The control panel can transmit these report codes to the monitoring station identifying which zone was restored. A zone is restored when it closes after generating an alarm or once the bell has cut-off after alarm generation. Please refer to Zone Restore Report Options on page 34. 9.2.7 Special Alarm Report CodesSections [195] and [196]Whenever the system generates an alarm due to one of the conditions listed below, the control panel can send the appropriate report code to the monitoring station identifying the type of alarm.Section [195]•Emergency Panic: Panic keys [1] and [3] have been pressed (see page 26).•Auxiliary Panic: Panic keys [4] and [6] have been pressed (see page 26).•Fire Panic: Panic keys [7] and [9] have been pressed (see page 26).•Recent Closing: Reports when an alarm is generated after arming the system within period defined by the Recent Close Delay (see page 33).Section [196]•Auto Zone Shutdown: A zone communicates more than the programmed number of transmissions in a single armed period (see page 16). •Duress: A Duress access code is keyed in (see page 11). •Keypad Lockout: If a consecutive number of invalid codes are entered into a keypad, the control panel can be set to deny access from all keypads for a specified period.• Future use9.2.8 Zone Tamper Report CodesSection [197] to [200]A report code can be programmed for each of the 15 available zones. Whenever a tamper or wire fault occurs on a zone, the control panel can send the appropriate report code to the monitoring station identifying which zone was tampered.9.2.9 Zone Tamper Restore Report CodesSections [201] to [204]A report code can be programmed for each of the 15 available zones. Whenever a tampered zone is restored, the control panel can send the appropriate report code to the monitoring station identifying which zone has been restored.If Tamper Recognition (see page 25) is disabled, the control panel will not report the occurrence of any tampers, wire faults or tamper restores.9.2.10 System Trouble Report CodesSection [205] to [207]Whenever the system generates one of the instances listed below, the control panel can send the appropriate report code to the monitoring station identifying the type of system trouble.Section [205]• Future use•AC Failure: The control panel has detected a loss of AC power. Transmission of this report code can be delayed (see Power Failure Report Delay on page 33).•Battery Failure: Backup battery is disconnected or battery voltage is ≤10.5V.•Auxiliary Supply: Auxiliary power supply has overloaded (current consumption is >1.1A).Section [206]•Bell Output Overload: Bell/siren output has overloaded (see page 4).•Bell Output Disconnected: Devices connected to the Bell Output have been disconnected.•Timer Loss: The control panel has detected a loss in time or clock failure (see page 36).•Fire Loop Trouble: The control panel has detected a tamper trouble on a fire zone. Section [207]•Wireless Low Battery: The battery voltage of an Magellan wireless transmitter (motion detector or contact switch) has dropped below recommended limits. •Module Fault: Will report if all keypads connected to the control panel have been disconnected or if a module with its corresponding supervision option enabled in the control panel (see pages 38 and 39) is disconnected.•Printer Fault: An error has occurred on the Printer Module.•Fail To Communicate: The control panel has failed all attempts to communicate with the monitoring station. The report code will be transmitted upon the next successful attempt.
30   Reference & Installation Manual   9.2.11 System Trouble Restore CodesSections [208] to [210]Whenever the system restores one of the troubles listed in System Trouble Report Codes on page 29, the control panel can send the appropriate report code to the monitoring station identifying the type of system trouble restore. If Telephone Line Monitoring is enabled (see page 34), the control panel can also transmit a TLM Restore report code.9.2.12 Special Reporting CodesSections [211] to [213]Whenever the system generates one of the instances listed below, the control panel can send the appropriate report code to the monitoring station identifying the type of system occurrence.Section [211]•Cold Start: The control panel was completely shutdown (no battery, no AC) and then was re-started.•Test Report: A test report has been generated automatically (see Auto Test Report on page 33).• Not available•PC Exit: The control panel has ended communication with WinLoad.Section [212]•Installer In: Installer has entered the programming mode.•Installer Out: Installer has exited the programming mode.• Future use• Future useSection [213]•Tx Supervision Loss: Wireless Transmitter Supervision (see SPC-319 Instruction Sheet) has been enabled and a transmitter is no longer communicating with the system.•Tx Supervision Restore: Reports when the above trouble has been restored• Future use• Future use9.3 Monitoring Station Telephone NumbersSection [151] = Phone#1, [152] = Phone#2, [153] = Backup Phone#: Up to 32 digits The 1759MG control panel can dial up to 2 different monitoring station telephone numbers. You can enter any digit from 0 to 9 and any special keys or functions (see Table 8) up to a maximum of 32 digits. For more information on how these telephone numbers are used, please refer to Event Call Direction on page 32 and Reporting Formats on page 30. After the Maximum Dialing Attempts (see page 33) to one monitoring station telephone number have failed, the control panel will then dial the backup telephone number. If the Alternate Dial Option (see page 33) is enabled, the control panel will dial the programmed backup telephone number after every failed attempt. If no backup telephone number is programmed, the control panel will never report to the backup telephone number. Also refer to Delay Between Dialing Attempts on page 33.9.4 Partition Account NumbersSection [143] = Partition 1, [144] = Partition 2All report codes are preceded by a 4-digit or 3-digit Partition Account Number to ensure correct identification in a partitioned system. Partition account numbers can be any hexa-digit from 1 to F. To enter a 3-digit account number, simply press the [FORCE] key followed by the 3-digit account number. Also, when using 3-digit account numbers, you must use 1-digit report codes.9.5 Reporting FormatsSection [140]: 1st digit = Format for Phone #1, 2nd digit = Format for Phone #2The Spectra 1759MG can use a number of different reporting formats and each monitoring station telephone number can be programmed with a different reporting format. The first digit entered into section [140] represents the reporting format used to communicate with Monitoring Station Telephone Number 1, the second digit represents the reporting format used to communicate with Monitoring Station Telephone Number 2. The Backup Telephone Number uses the same reporting format as the last monitoring station telephone number that was dialed.Table 8: Special Keys for Telephone NumbersPress Action or Value[STAY]*[BYP]#[MEM]switch from pulse to tone dialing or vice versa[TBL] or [TRBL]4-second pause[FORCE]deletes current digit[PG] or [FNC1] inserts blank space
Spectra 1759MG   31 If Hexadecimals (0 to FF) are used to program the report codes, verify that the pager also supports Hexadecimals. If the pager does not support Hexadecimals, use only the digits 0 to 9.UL Note: The installer is required to verify the complete compatibility of the DAC Receiver and formats at least once per year.9.5.1 Standard Pulse FormatsThe Spectra 1759MG can use the Ademco slow, Silent Knight and Sescoa standard pulse reporting formats (see Table 9 above).9.5.2 Ademco ExpressThe Ademco Express is a high-speed reporting format, which will transmit the 2-digit (11 to FF) report codes programmed into sections [160] to [213]. Unlike other Ademco formats, the Ademco Express does not use the Contact ID report codes. 9.5.3 Ademco Contact IDAdemco Contact ID is a fast communicator format that uses tone reporting instead of pulse reporting. This communicator format also uses a pre-defined list of industry standard messages and report codes that will suit most of your basic installation needs. Please refer to the Contact ID Report Codes List in the Programming Guide for a complete list of these report codes and messages. 9.5.4 Contact ID OptionsSection [136]: Dialer OptionsOption [3] OFF  = Programmable Codes Option [3] ON  = All Codes (default)When using the Programmable Codes format, use the Ademco Contact ID Report Codes List in the Spectra System Programming Guide (version 2.0 or higher) to program the desired report codes into sections [160] to [213]. Enter FF to use the default Contact ID report codes. Press the [FORCE] key to enter a 0 value. When using the All Codes format, the control panel will automatically generate Contact ID report codes for every event in sections [160] to [213]. Refer to the “All Codes” Ademco Contact ID Report Code List in the Spectra System Programming Guide. When using the Ademco Contact ID Programmable format, both telephone numbers must use this reporting format.9.5.5 Pager Reporting FormatSection [136]: Dialer Options[6] OFF / [7] OFF: 1 call to the pager/cellular telephone[6] OFF / [7] ON: 2 calls to the pager/cellular telephone[6] ON / [7] OFF: 3 calls to the pager/cellular telephone[6] ON / [7] ON: 4 calls to the pager/cellular telephoneUsing this format allows the control panel to transmit report codes to a pager or a cellular telephone. Since the control panel cannot confirm whether the transmission was successful or not, it can be programmed to call the pager or cellular telephone up to four times and transmit the report codes each time. To ensure that the report is received, the control panel transmits the account number, the report code and the # sign four times during each call. Also, refer to Pager Delay on page 32. 9.5.6 Pager Format Transmission OptionsSection [136]: Dialer OptionsOption [8] OFF = Transmit Report Code(s) after Pager Delay (default)Option [8] ON = Transmit Report Code(s) immediatelyThe Pager Reporting Format can be configured to transmit immediately or to transmit after a pager delay has elapsed. With option [8] ON, the control panel will immediately transmit (personal dialing) the report code(s) to a pager or a cellular phone. The Pager delay in section [083] will then become the length of time that the control panel will continue to transmit the report code(s). With option [8] OFF, the control panel will transmit the report code(s) to a pager or cellular phone only after the Pager delay has elapsed.Table 9: Reporting FormatsValue Entered Reporting Format 1 Ademco Slow (1400Hz, 1900Hz, 10BPS)2 Silent Knight Fast (1400Hz, 1900Hz, 10BPS)3 SESCOA (2300Hz, 1800Hz, 20BPS)4 Ademco Express (DTMF 4+2)5 (Default) Ademco Contact ID 6 Pager Format
32   Reference & Installation Manual   9.6 Pager Delay Section [083] 001 to 255 seconds, default = 5 secondsWhen using the Pager Reporting Format (see page 31), the control panel will wait for the Pager Delay period before transmitting the report codes. This is to allow time for the pager system to provide a dial tone or to bypass the “welcome” message before sending data.9.7 Event Call DirectionThis feature determines where each group of events will be reported. The control panel events are divided into five groups (see above) where each event group can be programmed to dial one or both monitoring station telephone numbers (MSTNs). When a reportable event occurs in the system, the control panel will verify that one of the two telephone numbers has been enabled. The control panel will begin by dialing the selected telephone number(s). If both numbers were selected it will begin with MSTN1. After the Maximum Dialing Attempts (see page 33) to one MSTN have failed, the control panel will then dial the backup telephone number. If the Alternate Dial Option (see page 33) is enabled, the control panel will dial the programmed backup telephone number after every failed attempt. If no backup telephone number is programmed, the control panel will never report to the backup telephone number. Also, refer to Delay Between Dialing Attempts on page 33.Example: The system is armed and zone 1 has been breached causing an alarm. If option [3] is off and option [4] is on in section [137], the control panel will attempt to communicate with MSTN2 in order to transmit the Zone 1 Alarm report code programmed in section [187]. 9.8 Dialing MethodSection [135]: Dialer OptionsOption [4] OFF = Pulse Dialing. (Also, refer to Pulse Ratio, below)Option [4] ON = Tone/DTMF Dialing (default)9.9 Pulse RatioSection [135]: Dialer OptionsOption [5] OFF = European Pulse Ratio of 1:2 Option [5] ON = U.S.A. Pulse Ratio of 1:1.5 (default)When using Pulse dialing, you can select one of two Pulse Ratios. Although most European countries use the 1:2 pulse ratio, the 1:1.5 ratio may provide better results in some cases. The same applies for North American countries. If the 1:1.5 pulse ratio is not providing the desired results, the 1:2 ratio may be used.9.10 Bell on Communication FailureSection [135]: Dialer Options Option [6] OFF = Bell On Communication Failure Disabled (default) Option [6] ON = Bell On Communication Failure EnabledIf the control panel fails to communicate with the monitoring station when the system is armed, it will enable the BELL output, setting off any bells or sirens connected to the output.9.11 Dial Tone DelaySection [136]: Dialer Options Option [5] OFF = Dialer will continue to dial if no dial tone is present after 4 seconds (default). Option [5] ON = Dialer will hang-up if no dial tone is present after 16 secondsSection [137]Option [1] ON = Call Telephone #1 forOption [2] ON = Call Telephone #2 forOption [3] ON = Call Telephone #1 forOption [4] ON = Call Telephone #2 forOption [5] ON = Call Telephone #1 forOption [6] ON = Call Telephone #2 forSection [138]Option [1] ON = Call Telephone #1 forOption [2] ON = Call Telephone #2 forOption [3] ON = Call Telephone #1 forOption [4] ON = Call Telephone #2 forArm/Disarm Report Codes in sections [160] to [186] (page 28)Alarm/Restore Report Codes in sections [187] to [196] (pages 28 to 29)Tamper/Restore Report Codes in sections [197] to [204] (page 29)Trouble/Restore Report Codes in sections [205] to [210] (pages 29 to 30)Special Report Codes in sections [211] to [213] (page 30)
Spectra 1759MG   339.12 Maximum Dialing AttemptsSection [081] 001 to 016 attempts, Default = 8 attemptsThe value programmed in section [081] determines how many times the control panel will re-dial the same monitoring station telephone number before proceeding to the next number. 9.13 Delay Between Dialing AttemptsSection [082] 000 to 255 seconds, Default = 20 seconds This delay determines the amount of time the control panel will wait between each dialing attempt. 9.14 Alternate Dial OptionSection [136]: Dialer OptionsOption [4] OFF = Alternate Dial Disabled (default)Option [4] ON = Alternate Dial EnabledWith option [4] OFF, the control panel will dial the backup telephone number programmed in section [153] after all attempts to one monitoring station telephone number have failed (see Maximum Dialing Attempts on page 33). With option [4] ON, the control panel will dial the backup telephone number after every failed attempt.9.15 Recent Close DelaySection [085] 000 to 255 seconds, Default = no delayIf after having armed the system, an alarm is generated within the period defined by the Recent Close Delay, the control panel will attempt to transmit the Recent Close report code programmed in section [195]. 9.16 Auto Test ReportSections [087] 000 = Disabled, 001 to 255 days, Default = Disabled   Section [110]: Time (HH:MM)The control panel will transmit the Test Report report code programmed into section [211] after the number of days programmed into section [087] has elapsed at the time programmed into section [110]. Use the 24-hour clock to program the time (i.e. 6:30PM = 18:30). The first Test Report will be transmitted within 24 hours after the feature is enabled at the time programmed in [110]. Example: Section [087] = 005 and section [110] = 13:00. The first Test Report will be sent at 1 PM that day and then the report will be sent every 5 days at 1 PM.9.17 Closing Delinquency TimerSection [095]000 = Disabled, 001 to 255 days, Default = DisabledAt midnight every day, the control panel will verify when the partition was last disarmed. If the partition has not been armed within the time programmed in the Closing Delinquency Timer, the control panel will transmit a Closing Delinquency event to the monitoring station.Example: The Closing Delinquency Timer for partition 1 in section [095] is programmed for 005 days. Spectra verifies when partition 1 was last disarmed at midnight every day. If partition 1 was not armed within the last 5 days, Spectra will transmit a Closing Delinquency event to the monitoring station.The Closing Delinquency Event and timer apply only to partition 1.9.18 Power Failure Report DelaySection [086] 001 to 255 minutes, Default = 15 minutesThe control panel will transmit the AC Failure report code programmed in section [205] after the Power Failure Report Delay period has elapsed. 9.19 Disarm Reporting Options    Section [131]: Arming /Disarming OptionsOption [1] OFF = Always Report DisarmingOption [1] ON = Report Disarming Only After Alarm (default)
34   Reference & Installation Manual   With option [1] OFF, the control panel will send the Disarming report codes (see page 28) to the monitoring station every time the system is disarmed. With option [1] ON, the control panel will send the Disarming report codes to the monitoring station when the system is disarmed following an alarm.9.20 Zone Restore Report OptionsSection [132]: Zone OptionsOption [6] OFF = Report On Bell Cut-Off (default)Option [6] ON = Report On Zone ClosureWith option [6] OFF, the 1759MG will send the Zone Alarm Restore report codes (see page 29) to the monitoring station when the zone has returned to normal and the Bell Cut-Off Timer has elapsed (see page 25). With option [6] ON, the 1759MG will send the Zone Alarm Restore report codes to the monitoring station as soon as the zone returns to normal or when the system is disarmed. 9.21 Telephone Line Monitoring (TLM) When enabled, the system verifies the existence of a telephone line once every second. A line test failure occurs when the TLM detects less than 3 volts for the period defined by the TLM Fail Timer. If the line test fails, the control panel’s STATUS LED flashes and generates one or more conditions as defined by the TLM settings below. These will be restored when the control panel detects the telephone line again. Please note that when the dialer detects an incoming call, the TLM test will stop for 1 minute.Section [135]: Dialer Options [1] OFF / [2] OFF: TLM Disabled[1] OFF / [2] ON: Trouble OnlyUpon line test failure, a TLM Trouble will appear in the keypad’s Trouble Display (see page 42).[1] ON / [2] OFF: Alarm If System Armed Upon line test failure, a TLM Trouble will appear in the keypad’s Trouble Display (see page 42) and if the system is armed, the control panel will generate an alarm.[1] ON / [2] ON: Silent Alarm Becomes Audible Upon line test failure, a TLM Trouble will appear in the keypad’s Trouble Display (see page 42) and causes a silent zone or silent panic alarm to switch to audible.9.21.1 TLM Fail TimerSection [079] 016 to 255 x 2 seconds, Default = 32 secondsIf TLM does not detect the existence of a telephone line for the duration of this period, the control panel will generate the condition(s) defined by the TLM options (see above). Part 10:  Programmable OutputsA PGM is a programmable output that toggles to its opposite state (i.e. a normally open PGM will close) when a specific event has occurred in the system. For example, a PGM can be used to reset smoke detectors, activate bells or strobe lights, open/close garage doors and much more. When a PGM closes, the control panel supplies a ground to the PGM activating any device or relay connected to it. When a PGM opens, the circuit opens from ground, therefore, cutting power to any devices connected to it. PGM1 A programmable output that provides up to 150mA. Refer to Alarm Relay and PGMs on page 4.PGM2 PGM2 is a programmable output that can provide up to 1A. PGM2 is designed to be used as a Strobe Output. For information refer to PGM Strobe Options on page 35. For connections, refer to Alarm Relay and PGMs on page 4.   Global PGMThe Global PGM allows you to use the control panel’s PGM Event List to activate PGMs located on a module or LCD keypad. For example, if you enable a module’s “Follows Global PGM” option, the PGM on the module will activate whenever the event programmed in section [124] occurs. Every PGM on every keypad and/or expansion bus module can be programmed to follow the event(s) defined by the Global PGM. 10.1 PGM Activation EventSections [120], [122], and [124]This feature allows you to program the control panel to activate a PGM when a specific event occurs in the system. The PGM will remain in its active state until the programmed PGM Deactivation Event occurs or when the PGM Delay period elapses (see page 35). For the Event List see the PGM Table in the Spectra 1759MG Programming Guide. To program a PGM Activation Event:
Spectra 1759MG   351) Enter section that represents the desired PGM. PGM1 = [120], PGM2 = [122], Global PGM = [124] 2) Enter the Event Group #. 3) Enter the Sub-Group #. 4) Enter the Partition #   (01 = Partition 1 02 = Partition 2 99 = Both Partitions) The “AC Loss” PGM Event will only occur after the Power Failure Report Delay elapses (see page 33).10.2 PGM Deactivation EventSections [121], [123], [125]After PGM activation, the PGM will return to its normal state (deactivate) when the programmed PGM Deactivation Event occurs. Instead of deactivating the PGM when a specific event occurs, the PGM can deactivate after a programmed period elapses (see PGM Delay below). For the Event List see the PGM Table in the Spectra 1759MG Programming Guide. If using the PGM Delay, these sections can be used as a second activation event.1) Enter section that represents the desired PGM. PGM1 = [121], PGM2 = [123], Global PGM = [125]2) Enter the Event Group #. 3) Enter the Sub-Group #. 4) Enter the Partition #   (01 = Partition 1 02 = Partition 2 99 = Both Partitions) 10.3 PGM Delay Section [066] = PGM1, [067] = PGM2, [068] = Global PGM001 to 255 seconds, 000 = Follows Deactivation Event, Default = 5 secondsInstead of deactivating the PGM on the occurrence of a specific event, the PGM will deactivate after the period programmed here has elapsed.If a PGM Delay is programmed, the deactivation event can be used as a second activation event.10.4 PGM Normal StateSection [126]: Options [4], [5] and [6]A PGM switches to its opposite state (i.e. a normally open PGM will close) when a specific event has occurred in the system. You can program each PGM output to be normally open (N.O.) or normally closed (N.C.) by enabling or disabling options [4], [5] and [6] in section [126]. Option [4] OFF = PGM1 Normally Open (Default)Option [4] ON  = PGM1 Normally ClosedOption [5] OFF = PGM2 Normally Open (Default)Option [5] ON  = PGM2 Normally ClosedOption [6] OFF = Global PGM Normally Open (Default)Option [6] ON  = Global PGM Normally Closed10.5 PGM2 Strobe OptionsSection [129]: General OptionsOption [1] OFF = PGM2 Output is Steady (Default)Option [1] ON  = PGM2 Output is Pulsed (Strobe)With option [1] enabled, PGM2 will flash on and off whenever activated. Otherwise, it will provide a steady output. Option [2] OFF = Disable PGM2 Pulse When System is Armed (Default)Option [2] ON  = Enable PGM2 Pulse When System is Armed Whenever the system is armed, PGM2 will flash once every 30 seconds until the system is disarmed.Option [3] OFF = Disable PGM2 Pulse on Arm/Disarm (Default)Option [3] ON  = Enable PGM2 Pulse on Arm/Disarm EnabledWith this option enabled, PGM2 will flash once to indicate the system has been armed and will flash twice to indicate that the system has been disarmed.10.6 Alarm Relay OptionsSection [127]: General OptionsOption [7] OFF = Alarm Relay Follows Bell Output (Default)Option [7] ON  = Alarm Relay Follows Global PGMWith this option off, the optional Alarm Relay will activate or deactivate whenever the Bell Output activates or deactivates. With the option on, the Alarm Relay will activate or deactivate whenever Global PGM activates or deactivates.
36   Reference & Installation Manual   Part 11: System Settings11.1 Hardware ResetPerforming a hardware reset will set all control panel settings to factory default except for the Panel ID and PC Password. Also, the event buffer will not be erased. To perform a power down reset:1) Make sure the Installer Lock is disabled (see below)2) Remove battery and AC power from the control panel.3) Set the RESET jumper to on by placing a jumper on the RESET pins of the control panel.4) Re-connect AC and battery power to the control panel.5) Wait 10 seconds and remove the jumper.11.2 Installer LockSection [282]000 = Disabled, 147 = Lock Enabled, Default = DisabledProgram 147 into section [282] to lock all programming. Performing a hardware reset will not affect the current panel settings. To remove the Installer Lock, enter 000. Please note that four seconds after resetting the control panel the STATUS LED on the control panel will flash fast for 5 seconds to indicate that the installer lock is enabled.11.3 Keypad Lockout FeatureSections [092] and [093]If a consecutive number of invalid codes are entered into a keypad, the control panel can be set to deny access from all keypads for a specified period and send the report code programmed in section [196]. Program the number of consecutive invalid codes from 001 to 255 (000 = disabled) into section [092]. Program the duration of the Keypad Lockout from 001 to 255 minutes into section [093]. If 000 is programmed in section [093], the keypads will not be locked-out, but the report code programmed in section [196] will be sent.11.4 Battery Charge CurrentSection [127]: General Options Option [5] OFF = Battery Charge Current: 350mA (default)Option [5] ON = Battery Charge Current: 700mA (40VA transformer required)11.5 PartitioningSection [127]: General Options Option [1] OFF = Partitioning Disabled (default)Option [1] ON = Partitioning EnabledThe 1759MG is equipped with a partitioning feature which can divide the alarm system into two distinct areas identified as Partition 1 and Partition 2. Partitioning can be used in installations where shared security systems are more practical, such as an office/warehouse building. When partitioned, each zone, each user code (see User Code Options on page 10) and some of the system's features can be assigned to Partition 1, Partition 2 or both (see Zone Partition Assignment on page 15). If the system is not partitioned, all user codes and features will be recognized as belonging to Partition 1.• Users can only arm partitions to which they have been assigned.• Only zones assigned to Partition 1 will arm/disarm when Partition 1 is armed or disarmed.• Only zones assigned to Partition 2 will arm/disarm when Partition 2 is armed or disarmed.• Zones assigned to both partitions will arm when both partitions are armed and will disarm when at least one disarms.• The following features can be programmed separately for each partition: Entry/Exit Delay Timer, Auto-arming Options, Bell Cut-Off Timer, Switch to Stay arming, PGM Events and Account Numbers. If the system is not partitioned, all zones, user codes, and features will be recognized as belonging to partition 1. Zones that have been manually assigned to partition 2 will no longer function.11.6 System Real-Time Clock Section [280] Program the current time into section [280] using the 24-hour clock (i.e. 8:30PM = 20:30). 11.7 Clock AdjustSection [088]000 = Disabled, 001 to 255, Default = Disabled 001 to 127 = + 1 to +127 seconds128 to 255 = -1 to -127 seconds
Spectra 1759MG   37If you notice a gain or loss in control panel time, calculate the average gain or loss per day and program the opposite amount in order to automatically correct the time setting every 24 hours. Example: If a control panel loses 4 minutes per month, this represents an average loss of 8 seconds per day. Therefore, programming 008 (plus 8 seconds) into section [088] would compensate for the 8-second loss. 11.8 Keypad Tamper SupervisionSection [128]: General Options Option [7] OFF = Keypad 1 Tamper Supervision Disabled (default)Option [7] ON = Keypad 1 Tamper Supervision EnabledOption [8] OFF = Keypad 2 Tamper Supervision Disabled (default)Option [8] ON = Keypad 2 Tamper Supervision EnabledThe control panel can be programmed to monitor the on-board tamper status of one or two keypads in the system. If Keypad 1 Tamper Supervision is enabled, the control panel will verify the tamper status of a keypad with its keypad zone set as Keypad Zone 1. If Keypad 2 Tamper Supervision is enabled, the control panel will verify the tamper status of the keypad with its keypad zone set as Keypad Zone 2. Ensure that the keypad’s on-board anti-tamper switch is enabled. For LED keypads, see Configuring The LED Keypad on page 8. For LCD keypads, see the appropriate Installation Guide.Regardless of whether the keypad zones are being used or not, if more than one keypad is set with the same keypad zone number, Keypad Tamper Supervision will be lost for that keypad zone. For example, if two keypads in your system have their keypad zones defined as Keypad Zone 1, the control panel will not recognize a Keypad 1 Tamper Supervision Failure. If a keypad tamper occurs, the control panel can transmit the appropriate Zone Tamper report code (see page 29) as originating from the zones specified by the Table 10. If the zone (as specified by Table 10) is enabled, the control panel will report the tamper as originating from the partition where the zone is assigned. If the zone is not enabled, the control panel will send the Zone Tamper report code as originating from partition 1. A Tamper/Zone Wiring Failure will also appear in the keypad’s trouble display (see page 42).When Reassign Keypad Zone 2 is enabled (see page 12), the Keypad Tamper Supervision for Keypad Zone 2 is lost. Therefore, Keypad Tamper Supervision will ONLY function on Keypad Zone 1.11.9 Keypad Audible Trouble WarningSection [127]: General Options Option [3] OFF = Keypad Beep on Trouble Disabled Option [3] ON = Keypad Beep on Trouble Enabled (default)When enabled, the keypads emit an intermittent beep tone whenever a trouble condition occurs in the system. The intermittent beep tone remains activated until the user enters the trouble display by pressing the [TBL] or [TRBL] key. The intermittent beeps will re-initialize whenever a new trouble occurs or the trouble restores and re-occurs. 11.10 Confidential ModeSection [126] Options [1], [2] and [3] Option [1] OFF = Confidential Mode Disabled (default)Option [1] ON = Confidential Mode Enabled Option [2] OFF = Keypads activate when an access code is entered Option [2] ON = Keypads activate when a key is pressed (default)Option [3] OFF = Confidential Mode Timer is 2 minutes Option [3] ON = Confidential Mode Timer is 5 seconds (default)If Confidential Mode is enabled and no actions are performed on the keypads for the time defined by the Confidential Mode Timer, all the keypad’s LEDs will be off and LCD screens will show “Paradox Family” until either a key is pressed or an access code is entered. When the system exits Confidential Mode, the keypads will display the system’s status. Confidential Mode is activated by enabling option [1]. Option [2] regulates whether the keypads will be activated at the touch of a key or only when an access code is entered. Option [3] determines the amount of time without action before the system enters Confidential Mode (5 seconds or 2 minutes).Table 10: Zone Tamper Report Code for Keypad Tamper Supervision FailureKeypad Tamper1759MGKeypad 1 Tamper Supervision =  Zone 6Keypad 2 Tamper Supervision =  Zone 7
38   Reference & Installation Manual   11.11 Installer Quick Functions KeysAfter entering the Installer Code, you can press a key to perform specific actions as described below.11.11.1 Installer Test Mode[ENTER] + [INSTALLER CODE] + [TBL] / [TRBL]The Installer Test Mode allows you to perform walk tests where the bell or siren will squawk and the keypad will emit a confirmation beep to indicate opened zones. To enter this mode, simply enter the Installer Code then press the [TBL] or [TRBL] key. The keypad will emit a confirmation beep. To disable this mode, press the [TBL] key again. The keypad will emit a rejection beep.11.11.2 Test Report[ENTER] + [INSTALLER CODE] + [MEM] Sends the Test Report report code programmed in section [211] to the monitoring station (see Reporting and Dialer settings on page 27). 11.11.3 Call WinLoad Software[ENTER] + [INSTALLER CODE] + [BYP] Refer to page 40.11.11.4 Cancel Communication [ENTER] + [INSTALLER CODE] + [STAY] Cancels all communication until the next reportable event.11.11.5 Answer WinLoad Software[ENTER] + [INSTALLER CODE] + [FORCE] Refer to page 41.11.12 PGM Modules SupervisionSection [129]: General OptionsOption [7] OFF = 4-PGM Output Module Supervision Disabled (default)Option [7] ON = 4-PGM Output Module Supervision Enabled By enabling this option, the control panel will supervise the 4-PGM Output Module (APR3-PGM4) connected to the Spectra bus. This means that whenever the module is disconnected or is not communicating with the control panel, the control panel will attempt to transmit the Module Fault report code programmed in section [210] and the Module Loss Failure will appear in the keypad’s trouble display (see page 42). Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and DGP-848. Modules with the APR3- prefix are compatible with Spectra (versions 2.0 and higher), DGP-848 and DGP-NE96.11.13 Printer Module SupervisionSection [129]: General Options Option [8] OFF = Printer Module Supervision Disabled (default)Option [8] ON = Printer Module Supervision Enabled By enabling this option, the control panel will supervise the Printer Module (APR3-PRT1) connected to the Spectra bus. This means that whenever the Printer Module is disconnected or is not communicating with the control panel, the control panel will attempt to transmit the Module Fault report code programmed in section [210] and the Module Loss Failure will appear in the keypad’s trouble display (see page 42). Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and DGP-848. Modules with the APR3- prefix are compatible with Spectra (versions 2.0 and higher), DGP-848 and DGP-NE96.11.14 Zone Expansion Bus Module SupervisionSection [129]: General Options Option [4] OFF = Zone Expansion Bus Module Supervision Disabled (default)Option [4] ON = Zone Expansion Bus Module Supervision Enabled By enabling this option, the control panel will supervise the 4- or 8-Zone Expansion Bus Module (SPC/APR3-ZX4 or SPC/APR3-ZX8) connected to the Spectra bus. This means that whenever the Zone Expansion Bus Module is disconnected or is not communicating with the control panel, the control panel will attempt to transmit the Module Fault report code programmed in section [210] and the Module Loss Failure will appear in the keypad’s trouble display (see page 42). Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and DGP-848. Modules with the APR3- prefix are compatible with Spectra (versions 2.0 and higher), DGP-848 and DGP-NE96.
Spectra 1759MG   3911.15 Wireless Transmitter Low Battery SupervisionSection [129]: General Options Option [6] OFF = Wireless Transmitter Low Battery Supervision Disabled (default)Option [6] ON = Wireless Transmitter Low Battery Supervision Enabled When option [6] in section [129] is enabled and the battery voltage of an Magellan wireless transmitter (motion detector or contact switch) has dropped below recommended limits, the control panel will attempt to transmit the Wireless Transmitter Low Battery report code programmed in section [210] and the Wireless Transmitter Low Battery Failure will appear in the keypad’s trouble display (see page 42). 11.16 Wireless Transmitter Supervision Options Section [132]: Zone Options[7] OFF / [8] OFF: Supervision Failure Recognition Disabled (default)When a tamper occurs on an Magellan wireless transmitter zone in a disarmed system, the control panel will display the zone as open in the keypad display, but will not generate an alarm. When it occurs on in an armed system, the control panel will follow the zone's Alarm Types setting (see page 16). This option is not permitted on UL systems.[7] OFF / [8] ON: Trouble OnlyWhen a tamper occurs on an Magellan wireless transmitter zone in a disarmed system, a Wireless Transmitter Supervision Loss will appear in the keypad’s trouble display (see page 42) and the control panel will attempt to transmit the TX Supervision Loss report code programmed in section [213]. When it occurs on in an armed system, the control panel will follow the zone's Alarm Types setting (see page 16).  [7] ON / [8] OFF: Silent AlarmWhen a tamper occurs on an Magellan wireless transmitter zone in a disarmed system, it functions the same as the Trouble Only setting, but it will also generate a silent alarm. A silent alarm will not trigger any bells or sirens, but the system will have to be disarmed. In an armed system, the control panel will follow the zone's Alarm Types setting (see page 16). [7] ON / [8] ON: Audible AlarmWhen a tamper occurs on an Magellan wireless transmitter zone in a disarmed system, it functions the same as the Trouble Only setting, except it will also generate an audible alarm. In an armed system, the control panel will follow the zone's Alarm Types setting (see page 16). 11.16.1 Restrict Arming on Supervision LossSection [131]: Arming/Disarming OptionsOption [6] OFF = Disabled (default)Option [6] ON = Restrict Arming on Wireless Transmitter Supervision LossThe control panel will not allow users to arm the system if it receives a Supervision Loss signal. Please note that the Wireless Transmitter Supervision Options (see page 39) must be enabled. The control panel will not arm any partition until all Supervision Loss trouble conditions are rectified.11.16.2 Supervision Bypass OptionsSection [131]: Arming/Disarming OptionsOption [7] OFF = Generate Supervision Loss if detected on a Bypassed Wireless Transmitter Zone (default)Option [7] ON = No Supervision Loss if Detected on a Bypassed Wireless Transmitter Zone When this feature is enabled, the Wireless Transmitter Supervision Options will follow the zone's bypass definition. This means the control panel will not perform any action if a Supervision Loss occurs on a bypassed zone. When this feature is disabled, the Wireless Transmitter Supervision Options will ignore the bypass definition. This means the control panel will generate an incident as per Wireless Transmitter Supervision Options if a supervision loss occurs on a bypassed zone.11.17 Reprogram All Expansion ModulesSection [750]After removing an expansion bus module from the communication bus, the control panel keeps the module’s programmed sections in memory. Therefore, if you add or replace a module or when you have downloaded the contents of the Paradox Memory Key (refer to Programming Using A Paradox Memory Key* on page 9), you can reprogram the modules with the settings saved in the control panel.  To do so, enter section [750] and press [ENTER]. The keypad will emit 2 beeps every second while downloading.
40   Reference & Installation Manual   Part 12: Settings for WinLoad SoftwareWinLoad has not been verified by UL12.1 Panel Answer OptionsThe following two options define how the control panel answers an incoming call from a computer using the WinLoad Software for Windows®. 12.1.1 Answering Machine OverrideSection [077]000 = Disabled, 010 to 255 seconds, Default = DisabledWhen using the WinLoad software to communicate remotely with an installation site that uses an answering machine or service, the answering machine override must be programmed. Using the WinLoad software you will call the control panel, hang up, then call back. If the installation site is called back within the programmed delay period, the control panel will override the answering machine or service by picking-up the line after the first ring on the second call. You must wait at least 10 seconds before attempting the second call, otherwise, the control panel will think it is the same call. For details on how to use the WinLoad software, refer to the WinLoad Help Manual.Example: A security installation is using an answering machine set to answer after three rings. If section [077] has been programmed with 040 (40 seconds) and the second call is made within 40 seconds, the control panel will pick up the line on the first ring. If it takes more than 40 seconds, the control panel will not answer on the first ring and the answering machine will answer after three rings. 12.1.2 Number of RingsSection [078]000 = disabled, 001 to 015 rings, Default = 8 rings This value represents the number of rings the control panel will wait before picking-up the line. If the line is not answered after the number of programmed rings, the control panel will answer the call. You must wait at least 10 seconds before attempting the second call or the control panel will think it is the same call.12.2 Panel IdentifierSection [141]0000 to FFFFThis 4-digit code identifies the control panel to the WinLoad software before initiating communication. The control panel will verify that the Panel Identifier in the WinLoad software is the same. If the codes do not match, the control panel will not establish communication. Therefore, be sure to program the same panel identifier into both the Spectra control panel and the WinLoad software. 12.3 PC PasswordSection [142]0000 to FFFFThis 4-digit password identifies the PC to the panel before establishing communication. Program the same PC Password into both the Spectra control panel and the WinLoad software. If the passwords do not match, the WinLoad software will not establish communication. 12.4 PC Telephone NumberSection [150]Up to 32 digitsThe control panel will dial this number when trying to initiate communication with a computer using the WinLoad software. You can enter any digit from 0 to 9 and any special keys or functions (see Table 8 on page 30) up to a maximum of 32 digits. 12.5 Call WinLoad Software[ENTER] + [INSTALLER CODE] + [BYP] The control panel will dial the PC Telephone Number programmed in section [150] in order to communicate with the WinLoad software. The control panel and the WinLoad software will verify that the Panel Identifier and the PC Password match before establishing communication.
Spectra 1759MG   4112.6 Answer WinLoad Software[ENTER] + [INSTALLER CODE] + [FORCE] In order to perform on-site upload/download connect your computer directly to the control panel using an ADP-1 line adapter. In the WinLoad software set Dialing Method to Blind Dial. Program the panel telephone number in WinLoad software and follow the instructions on the ADP-1 adapter. When the computer has dialed, press [ENTER] followed by the Installer Code, then press the [FORCE] key to manually answer the WinLoad software from the control panel.12.7 Auto Event Buffer TransmissionSection [136]: Dialer OptionsOption [2] OFF = Auto Event Buffer Transmission Disabled (default)Option [2] ON = Auto Event Buffer Transmission EnabledWhen the event buffer reaches 50% capacity, the control panel will make two attempts to establish communication with a PC using the WinLoad software by calling the PC Telephone Number programmed in section [150]. The WinLoad software must be in Wait to Dial mode. When the system establishes communication, it will upload the contents of the event buffer to the WinLoad software. If communication is interrupted before completing transmission or if after two attempts communication is not established, the system will wait until the Event Buffer attains another 50% capacity before attempting to re-communicate with the monitoring station. When the Event Buffer is full, each subsequent new event will erase the oldest event in the buffer.12.8 Call Back WinLoadSection [136]: Dialer Options Option [1] OFF = Call Back WinLoad Disabled (default)Option [1] ON = Call Back WinLoad EnabledFor additional security, when a PC using the WinLoad software attempts to communicate with the control panel, the control panel can hang up and call the PC back in order to re-verify identification codes and re-establish communication. When the control panel hangs up, the WinLoad software automatically goes into Wait for Call mode, ready to answer when the control panel calls back. Please note that the PC Telephone Number must be programmed in section [150] in order to use the Call Back feature.
42   Reference & Installation Manual   Part 13:  User Operation13.1 Trouble Display The Spectra system continuously monitors fourteen possible trouble conditions. When a trouble condition occurs, the [TBL] key or [TRBL] indicator will illuminate on the LED keypads or “Trouble” will appear on the LCD keypad’s screen. Press the [TBL] or [TRBL] key to switch to the trouble display. The [TBL] key or [TRBL] indicator will flash and lights corresponding to an existing trouble condition will illuminate on the LED keypads (see Table 11) or the appropriate trouble message will appear on the LCD keypad. Press the [CLEAR] key to exit the trouble display. Please note that the keypad can be programmed to emit a BEEP every 5 seconds whenever a new trouble condition has occurred. Pressing the [TBL] or [TRBL] key will stop the beeping.Table 11: Trouble ListLED # Description Details[1] No/Low Battery Failure The control panel performs a dynamic battery test under load every 60 seconds. This trouble indicates that the back up battery is disconnected or that the battery should be replaced, as it will not provide adequate current in case of AC loss. This trouble will also appear when the control panel is running on battery power and the battery voltage has dropped to 10.5V or lower. This means the battery must be recharged or replaced.[2] Wireless Transmitter Low Battery The battery voltage of an Magellan wireless transmitter has dropped below recommended limits. To determine the zones generating the trouble, examine the Low Battery LED indicators on all the transmitters. The batteries should be replaced.[3] Power Failure Upon power failure, the AC LED on all keypads will turn off. The control panel can transmit the report code programmed in section [205]. This report code can be delayed by programming a Power Failure Report Delay in section [086]. The AC LED turns back on as soon as power is restored.[4] Bell Disconnected This trouble occurs when a bell or siren is not connected to the bell output terminals. If you are not using the BELL terminals, connect a 1KΩ resistor across the bell output. [5] Maximum Bell Current The BELL output uses a fuseless circuit and will automatically shut down if the current exceeds 3A. After opening the short or reducing the load, the bell current is restored upon the following alarm generation. This trouble indicator will only appear when a condition has occurred that would activate the bell output (e.g. during an alarm). [6] Maximum Auxiliary Current The auxiliary output uses a fuseless circuit to protect the power supply against current overload and automatically shuts down if the current exceeds 1.1A. After opening the short or reducing the load, the panel will restore power to the auxiliary output.[7] Communicator Report Fail The control panel has failed all attempts to communicate with the central monitoring station.[8] Timer Loss The control panel’s internal clock must be re-programmed. To re-program the timer press the [8] key followed by the current time using the 24-hour clock (i.e. 8:30PM = 20:30).[9] Tamper/Zone Wiring Fail If the Tamper Recognition options are enabled (see page 25), this trouble indicates a wiring problem on one or more zones or that the cover has been removed on one or more wireless transmitters. To provide line short recognition the zone connections must have EOL resistors. If you press the [9] key, the keypad will display which zones are in trouble. Enter the Installer Code to clear Tamper troubles.[10] Telephone Line Monitoring If the Telephone Line Monitoring (TLM) feature is enabled (see section [135]), this trouble indicates that the control panel has not detected the presence of a telephone line for 30 seconds.[STAY] or [11]Fire Loop Trouble Indicates a wiring problem on a fire zone. Press [STAY] to view the zones that are generating this trouble.
Spectra 1759MG   4313.2 Programming Access CodesAccess codes are personal identification numbers that allow you to enter certain programming modes, arm or disarm your system as well as activate or deactivate PGMs. The Spectra security system supports the following:System Master Code arms or disarm partitions using any arming method and can create, modify or delete any user access code. Only the System Master Code can modify or delete user access codes assigned to both partitions.Master Code 1 is permanently assigned to partition 1 and can be used to create, modify or delete user access codes that are assigned to partition 1. Master Code 2 is permanently assigned to partition 2 (except when partitioning is disabled, Master Code 2 will be assigned to partition 1) and can be used to create, modify or delete user access codes that are assigned to the same partition. 45 User Access Codes (including 1 Duress code)   13.3 Disarming & Deactivating an Alarm To disarm an already armed system or to deactivate an alarm, simply key in a valid access code. Program a designated entry/exit point, such as the front door or the garage door with an entry delay timer. When these entry/exit point are opened (breached), it will set off a timer. The system will not generate an alarm until this timer elapses, giving users enough time to enter the premises and disarm the system. Any user can disarm the system, except users have been assigned the Arm Only Option.[FORCE] or [16]Keypad Fault If the keypad is no longer communicating with the control panel, the [TBL] or [TRBL] will flash, the [FORCE] key will illuminate (the LCD keypad displays “Keypad Fault”) and the keypad will emit four consecutive beeps at 5-second intervals. Press any key on the keypad to terminate the “beeping” sequence. When communication has been restored, the system will revert to previous status.[BYP] or [12]Module Loss A bus module is no longer communicating with the control panel. The module’s supervision option must be enabled in section [129].[MEM]or [13]Wireless Transmitter Supervision Loss One or more wireless transmitters are no longer communicating with the receiver. If you press the [MEM] key, the keypad will display which zones are in trouble. How Do I Program Access Codes?1) Press [ENTER].2) Key in the [SYSTEM MASTER CODE] or [MASTER CODE].3) Key in 3-digit [SECTION] (see Table below).4) Key in new 4- or 6-digit [ACCESS CODE].[ENTER] flashes. Return to step 3.How Do I Delete Access Codes?1) Repeat steps 1 to 3 (see above).2) Press the [FORCE] key once for each digit in the access code (4 or 6 times) until the keypad emits a confirmation beep.Section User Codes[001]User Code 001 = System Master Code[002]User Code 002 = Master Code 1[003]User Code 003 = Master Code 2[004] to [047]User Code 004 to User Code 047[048]User Code 048 or Duress CodeHow Do I Disarm the System or Deactivate an Alarm?1) Key in your [ACCESS CODE]*.The arm or alarm indication will turn off and the keypad will emit a confirmation beep.*IF YOU HAVE ACCESS TO BOTH PARTITIONS:Press the key corresponding to the partition you wish to Disarm or to Disarm both partitions, press the [1] key then after the confirmation beep press the [2] key. Table 11: Trouble ListLED # Description Details
44   Reference & Installation Manual   13.4 Regular ArmingThis method, commonly used for day-to-day arming, will arm all the zones in the selected partition. If you make a mistake, the keypad will emit a rejection beep. When you have correctly armed the system, the appropriate ARM indication will turn on and the exit delay will be initiated. Please note that Regular arming can also be activated through Auto-arming, Keyswitch arming or One-touch arming. 13.5 Stay ArmingThis method allows users to remain in the protected area while partially arming the system. For example, when going to sleep at night, entry/exit points like doors and windows can be armed while other zones like motion detectors remain deactivated. Please note that fire zones cannot be bypassed.If you make a mistake, the keypad will emit a rejection beep. When you have correctly Stay armed the system, the appropriate ARM or STAY indication appears and the exit delay is initiated. Stay arming can also be activated using Auto-arming, Keyswitch arming or One-touch arming. The user code must have the Stay Arming Option enabled.13.6 Instant ArmingAfter Stay arming the system and during its exit delay, press and hold the [STAY] key for 3 seconds. You should hear a confirmation beep. This will switch all armed zones to Instant zones. If you have access to both partitions: To Instant arm one partition, press [STAY] + [ACCESS CODE] + Select Partition + [CLEAR] + press & hold [STAY] To Instant arm both partitions, press [STAY] + [ACCESS CODE] + [1] + [2] + press & hold [STAY] 13.7 Force Arming (Not to be used with UL Installations)Force arming allows users to rapidly arm the system, without having to wait for all zones in the system to be closed. Force arming is commonly used when a motion detector is protecting the area occupied by a keypad. Therefore, when arming the system, if the motion detector is set as a Force Zone, the control panel will ignore the zone and allow users to arm the system even if the zone is open. Any open Force Zones at the time of arming will be considered deactivated by the control panel. If during this period a deactivated zone is closed, the control panel will revert that zone to active status, hence, will generate an alarm if breached. If you make a mistake, the keypad will emit a rejection beep. When correctly Force armed, the appropriate arm indication appears and the exit delay will initiate. Please note that Force arming can also be activated using One-Touch Force arming. Also, note that the user access code must have the Force Arming Option enabled.13.8 Manual Bypass ProgrammingManual Bypass Programming allows users to program the alarm system to ignore (deactivate) specified zones the next time the system is armed. The access code must have the Bypass Programming Option enabled. Please note that fire zones cannot be bypassed. Manual Bypass Programming can also be activated using One-Touch Bypass Programming.How Do I Regular Arm?1) Green “READY” indicator must be illuminated. Unless the system is partitioned, in which case all zones in the desired partition must be closed.2) Key in a valid [ACCESS CODE]*.*IF YOU HAVE ACCESS TO BOTH PARTITIONS:Press the key corresponding to the partition you wish to arm. To arm both partitions, press the [1] key then after the confirmation beep press the [2] key.How Do I Stay Arm?1) All zones in the desired partition (except Stay Zones) must be closed.2) Press the [STAY] key.3) Key in a valid [ACCESS CODE]*.*IF YOU HAVE ACCESS TO BOTH PARTITIONS:Press the key corresponding to the partition you wish to Stay arm. To Stay arm both partitions, press the [1] key then after the confirmation beep press the [2] key. How Do I Force Arm?1) All zones in the desired partition (except Force Zones) must be closed.2) Press the [FORCE] key.3) Key in a valid [ACCESS CODE]*.*IF YOU HAVE ACCESS TO BOTH PARTITIONS:Press the key corresponding to the partition you wish to Force arm. To arm both partitions, press the [1] key then after the confirmation beep press the [2] key.
Spectra 1759MG   4513.8.1  Bypass Recall FeatureAfter disarming the system, the control panel will erase the bypass entries. By using the Bypass Recall Feature, you can reinstate the previous bypass entries saved in memory. This eliminates the need to manually program the bypass entries every time you arm the system. The access code must have the Bypass Programming Option enabled.13.9 One-Touch ArmingOne-touch arming allows users to arm the system without using an access code. Simply press and hold a key. One-touch arming can be used to allow specific individuals like service personnel (i.e. cleaners, maintenance) to arm the system when leaving the protected area, without giving them access to any other alarm system operations.One-Touch Regular Arming: Press and hold the [ENTER] key for 3 seconds* to arm all zones in the partition.One-Touch Force Arming: Press and hold the [FORCE] key for 3 seconds* to bypass any open Force Zones. One-Touch Bypass Programming: Press and hold the [BYP] key for 3 seconds* to access Bypass Programming Mode.One-Touch Stay Arming: Press and hold the [STAY] key for 3 seconds* to arm all zones not defined as Stay Zones. Fast Exit - When the system is already Stay armed:•To Exit and Stay Arm: Press and hold the [STAY] key for 3 seconds*. The system will switch to exit delay. At the end of the exit delay period, the system will return to Stay arming.•To Exit and Regular Arm: Press and hold the [ENTER] key for 3 seconds*. The system will switch to exit delay. At the end of the exit delay period, the control panel will switch to Regular arming.•To Exit and Force Arm: Press and hold the [FORCE] key for 3 seconds*. The system will switch to exit delay. At the end of the exit delay period, the control panel will switch to Force arming.13.10 Keyswitch ArmingA keyswitch can be used to arm and disarm the system. Assign the keyswitch to a specific partition and program the keyswitch to Stay or Regular arm the assigned partition. Also program the keyswitch to function as a Maintained or Momentary keyswitch. To arm the system using a Maintained Keyswitch, set the keyswitch to the ON position. To disarm the system set the keyswitch to the OFF position. To arm the system using a Momentary Keyswitch, set the keyswitch to the ON position then turn it back to the OFF position. Repeating this sequence will disarm the system. 13.11 Panic AlarmsIn case of emergency, the Spectra system provides up to three panic alarms. These panic alarms, if programmed, will immediately generate an alarm after pressing and holding two specific keys for two seconds, as described below. Press and hold keys [1] and [3] for a panic alarm. Press and hold keys [4] and [6] for a panic or medical alarm. Press and hold keys [7] and [9] for a panic or fire alarm.13.12 Auto-Arming (Not to be used with UL installations)Each partition can be programmed to arm every day at the time specified by the Auto-arm Timer or for the period specified by the No Movement Timer. The user can program the Auto-arm Timer by using the System Master Code, Master Code 1 or Master How do I Program Bypass Entries?1) Press the [BYP] key.2) Key in a valid [ACCESS CODE]*.3) Select one or more [ZONES] you wish to bypass.4) Once you have entered the desired bypass entries, press the [ENTER] key to accept these entries.*IF YOU HAVE ACCESS TO BOTH PARTITIONS:Press the key corresponding to the desired partition. How Do I Recall Bypass Entries?1) Press the [BYP] key.2) Key in your [ACCESS CODE]*.3) Press the [BYP] key. Previously bypassed zones will illuminate.4) Press the [ENTER] key.*IF YOU HAVE ACCESS TO BOTH PARTITIONS:Press the key corresponding to the desired partition. * If you have access to both partitions after activating a one-touch feature, press the key corresponding to the desired partition. To select both partitions, press the [1] key then after the confirmation beep press the [2] key.
46   Reference & Installation Manual   Code 2. Please note that the control panel will enter a 60-second exit delay period before arming the system. At this point, Auto-arming can be cancelled by entering a valid access code.13.13 Alarm Memory DisplayA record of all alarm situations that occur will be stored in memory. After disarming the system, pressing the [MEM] key will display which zones were in alarm during the alarm period. To exit the Alarm Memory Display, press the [CLEAR] key. The control panel will erase the contents of the alarm memory every time the system is armed. 13.14 Programming Chime ZonesUsers can program which zones will be Chime Enabled. A Chime Enabled zone will cause the keypad to emit a rapid intermittent beep tone (BEEP-BEEP-BEEP-BEEP) advising the user every time it is opened. Each keypad must be Chime Programmed separately.10-ZONE LED KEYPAD:Press and hold any key from [1] to [10] for 3 seconds to activate or deactivate Chiming for zones 1 to 10. For example, press and hold the [1] key to enable chiming on zone 1. If after pressing and holding a key, the keypad emits a confirmation beep, this means the chime feature has been enabled for that zone. If the keypad emits a rejection beep, this means the chime feature has been disabled for the corresponding zone.16-ZONE LED KEYPAD:Press and hold the [9] key. Enter the 2-digit (01 to 15) zone number(s). When the corresponding LED is on, the zone is chimed. When the corresponding LED is off, the zone is unchimed. When the desired zones are chimed, press [ENTER]. LCD KEYPAD:Press and hold the [9] key. Enter the 2-digit (01 to 16) zone number(s), or use the arrow keys to scroll through the zones. and when the appropriate zone is displayed, press the [FNC1] key. When the desired zones are chimed, press [ENTER].13.15 Keypad Muting (Not to be used with UL installations)Press and hold the [CLEAR] key for 3 seconds to enable or disable keypad muting. When muted, the keypad will only beep when a key is pressed or when the keypad emits a Rejection or confirmation beep. All other beep functions are disabled.13.16 Keypad Backlight (1686H and 1686V only)The illumination level behind the keys can be modified to suit the user’s needs. There are four backlight levels. The [MEM] key is used to set the desired level. Each consecutive push of the [MEM] key will increase the backlight level until the maximum level is reached. After reaching the maximum level, the backlight level will return to the lowest level and the whole process is repeated. To change the backlight level:How do I Modify The Backlight?1) Press and hold the [MEM] key for 3 seconds.2) The [MEM] key will illuminate.3) Press the [MEM] key to set the desired backlight level.4) Press [CLEAR] or [ENTER] to exit.
Spectra Series   47FCC WarningsIMPORTANT INFORMATIONThis equipment complies with Part 68 of the FCC rules subpart D and CS-03. Inside the cover of this equipment is a label that contains, among other information, the FCC registration number of this equipment.NOTIFICATION TO TELEPHONE COMPANYUpon request, customer shall notify telephone company of particular line to which the connection will be made, and provide the FCC registration number and the ringer equivalence of the protective circuit.FCC REGISTRATION NUMBER:5A7CAN-22633 - AL - ERINGER EQUIVALENCE NUMBER:0.1B (U.S. & CANADA)USOC JACK: RJ31X (USA), CA31A (CANADA)TELEPHONE CONNECTION REQUIREMENTSExcept for telephone company provided ringers, all connections to the telephone network shall be made through standard plugs and telephone company provided jacks, or equivalent, in such a manner as to allow for easy, immediate disconnection of terminal equipment. Standard jacks shall be so arranged that, if plug connected thereto is withdrawn, no interference to operation of equipment at customer's premises which remains connected to telephone network shall occur by reason of such withdrawal.INCIDENCE OF HARMShould terminal equipment/protective circuitry cause harm to telephone network, telephone company shall, where practicable, notify customer that temporary disconnection of service may be required; however, where prior notice is not practicable, the telephone company may temporarily discontinue service if action is deemed reasonable in circumstances. In case of temporary discontinuance, telephone company shall promptly notify customer and will be given opportunity to correct the situation.CHANGES IN TELEPHONE COMPANY EQUIPMENT OR FACILITIESThe telephone company may make changes in its communication facilities, equipment operations or procedures, where such actions are reasonably required and proper in its business. Should any such changes render customer's terminal equipment incompatible with the telephone company facilities, the customer shall be given adequate notice to effect the modifications to maintain uninterrupted service.GENERALThis equipment shall not be used on coin telephone lines. Connection to party line service is subject to state tariffs.RINGER EQUIVALENCE NUMBER (REN)The ren is useful to determine the quantity of devices that you may connect to your telephone line and still have all of those devices ring when your telephone number is called. In most, but not all areas, sum of the   ren's of all devices connected to one line should not exceed five (5.0). To be certain of the number of devices that you may connect to your line, you may want to contact your local telephone company.EQUIPMENT MAINTENANCE FACILITYIf you experience trouble with this telephone equipment, please contact facility indicated below for information on obtaining service or repairs. The telephone company may ask that you disconnect this equipment from network until problem is corrected or until you are sure that the equipment is not malfunctioning.FCC PART 15, WARNINGS INFORMATION TO USERThis equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to equipment intermittently, the user is encouraged to try to correct the interference by one or more of the following measures: (1) re orient or relocate the receiving antenna; (2) increase the separation between the equipment and receiver; (3) connect the equipment to an outlet on a circuit other than the one to which the receiver is connected, or (4) consult the dealer or an experienced radio/tv technician for assistance.CAUTION: The user is cautioned that any changes or modifications not expressly approved by Paradox Security Systems could void the user’s authority to operate/use the equipment.WARRANTYParadox Security Systems Ltd. (“Seller”) warrants its products to be free from defects in materials and workmanship under normal use for a period of one year. Except as specifically stated herein, all express or implied warranties whatsoever, statutory or otherwise, including without limitation, any implied warranty of merchantability and fitness for a particular purpose, are expressly excluded. Because Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller, Seller cannot guarantee the performance of the security system and shall not be responsible for circumstances resulting from the product’s inability to operate. Seller obligation and liability under this warranty is expressly limited to repairing or replacing, at Seller's option, any product not meeting the specifications. Returns must include proof of purchase and be within the warranty period. In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental, including without limitation, any damages for lost profits stolen goods, or claims by any other party, caused by defective goods or otherwise arising from the improper, incorrect or otherwise faulty installation or use of the merchandise sold. Notwithstanding the preceding paragraph, the Seller’s maximum liability will be strictly limited to the purchase price of the defective product. Your use of this product signifies your acceptance of this warranty.*BEWARE: Dealers, installers and/or others selling the product are not authorized to modify this warranty or make additional warranties that are binding on the Seller. ATTACHMENT LIMITATION NOTICEThe Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction.Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.
48   Reference & Installation Manual   CAUTION: Users should not attempt to make such connections themselves, but should contact the appropriate electrical inspection authority, or electrician, as appropriate.The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all of the devices does not exceed 100. Industry Canada certification is only applicable to installation of devices which include transformers approved by the Canadian Standards Association (CSA).RESTRICTIONS CONCERNANT LE RACCORDEMENT DE MATÉRIELL'étiquette d'Industrie Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est conforme à certaines normes de protection, d'exploitation et de sécurité des réseaux de télécommunications. Le Ministère garantir toutefois pas que le matériel fonctionnera à la satisfaction de l'utilisateur.Avant d'installer ce matériel, l'utilisateur doit s'assurer qu'il est permis de le raccorder aux installations de l'entreprise locale de télécommunication. De plus, le matériel doit être installé en suivant une méthode acceptable de raccordement. L'abonné ne doit pas oublier qu'il est possible que la conformité aux conditions énoncées ci-dessus n'empêchent pas la dégradation du service dans certaines situations. Les réparations de matériel homologué doivent être effectuées par un centre de service d'entretien canadien autorisé désigné par le fournisseur. La compagnie de télécommunications peut demander à l'utilisateur de débrancher un appareil à la suite de réparations ou de modifications effectuées par l'utilisateur ou à cause d'un mauvais fonctionnement.Pour sa propre protection, l'utilisateur doit s'assurer que tous les fils de mise à la terre de la source d'energie électrique, des lignes téléphoniques et des canalisations d'eau métalliques, s'il y en a, sont raccordés ensemble. Cette précaution est particulièrement importante dans les régions rurales.AVERTISSEMENT: L'utilisateur ne doit pas tenter de faire ces raccordements lui-même; il doit avoir recours à une service d'inspection des installations électriques, ou à un électricien, selon le cas.L'indice de charge (IC) assigné à chaque dispositif indique, pour éviter toute surcharge, le pourcentage de la charge totale qui peut être raccordée à un circuit téléphonique bouclé utilisé par ce dispositif. La terminaison du circuit bouclé peut être constituée de n'importe quelle combinaison de dispositifs, pourvu que la somme des indices de charge de l'ensemble des dispositifs ne dépasse pas 100.La certification d'Industrie Canada s'applique seulement aux installations d'appareils utilisant un transformateur approuvé par l'Association Canadienne de Normalisation (CSA).UL AND ULC WARNINGS UL AND C-UL INSTALLATION NOTESThis equipment is UL listed in accordance with standard UL1023 (Household Burglar -- Alarm Systems Units), standard UL985 (Household Fire Warning Units) and standard UL1635 (Digital Alarm Communicator System Units). This equipment has the capability of being programmed with features not verified for use in UL installations. To stay within these standards, the installer should use the following guidelines when configuring the system:• All components of the system should be UL listed for the intended application.• If the system will be used for “Fire” detection, the installer should refer to NFPA Standards #72, Chapter 2. In addition, once installation is complete, the local fire authority must be notified of the installation.• This equipment must be verified by a qualified technician once every three years.• All keypads must use an anti-tamper switch.• Maximum allowed entry delay is 45 seconds.• Maximum allowed exit delay is 60 seconds.• Minimum 4 minutes for bell cut-off time.• The following features do not comply with UL requirements: Bypass Recall and Auto Trouble Shutdown. • Do not connect the primary indicating device to a relay. The installer must use the bell output.• To comply with UL985, the auxiliary power output should not exceed 200mA. Please refer to Table 2: Current Consumption Table on page 4.• Do not connect the zone ground terminal with UL Listed products.• The metallic enclosure must be grounded to the cold water pipe.• All outputs are Class 2 or power-limited, except for the battery terminal.The Class 2 and power-limited fire alarm circuits shall be installed using CL3, CL3R, CL3P, or substitute cable permitted by the National Electrical Code, ANSI/NFPA 70.RECOMMENDED:• EOL resistor part #2011002000•For UL Installations: Basler Electric BE156240CAA007 16.5VAC min 40VA• 12Vdc 4Ah rechargeable acid/lead or gel cell backup battery (YUASA model #NP7-12 recommended) for residential use. Use a 7Ah battery to comply with fire requirements.• Wheelock 46T-12 sirenWARNING: This equipment must be installed and maintained by qualified service personnel only.© 2002-2004 Paradox Security Systems Ltd. All rights reserved.Specifications may change without prior notice. One or more of the following US patents may apply: 6215399, 6111256, 5751803, 5721542, 5287111, 5119069, 5077549, 5920259 and 5886632. Canadian and international patents may also apply.Spectra, WinLoad, InTouch and Digiplex are trademarks or registered trademarks of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries.
Spectra Series   49INDEXNumerics24Hr. Buzzer Zone ...........................................................1424Hr. Delayed Fire Zone  .................................................1524Hr. Standard Fire Zone  ................................................15AAC Failure Report Code  ..................................................29AC Power ...........................................................................2Access Codes ..................................................................10Length ........................................................................10Programming ...............................................................43Account Numbers  ............................................................30Ademco Contact ID ..........................................................31Ademco Contact ID Options  ............................................31Ademco Express ..............................................................31Adjust Clock .....................................................................36Alarm Memory Display .....................................................46Alarm Options ..................................................................25Alarm Relay  .......................................................................4Options .......................................................................35Alarm Report Code Transmission, Delay  ........................17Alarm Types .....................................................................16Alternate Dial Option ........................................................33Answer Upload/Download Software  ................................38Answer WinLoad Software  ..............................................41Answering Machine Override ...........................................40Arming and Disarming Options ........................................22Arming Report Codes  ......................................................28Auto Event Buffer Transmission  ......................................41Auto Force Arming ...........................................................23Auto Test Report ..............................................................33Auto Zone Shutdown  .......................................................16Counter .......................................................................16Report Code ................................................................29Auto-ArmingOn No Movement .........................................................23Options .......................................................................24Timer ..........................................................................23Timing .........................................................................23Auxiliary Panic Report Code ............................................29Auxiliary Power ..................................................................4Auxiliary Supply Report Code ..........................................29BBacklight, Keypad ............................................................46Backup Battery  ..................................................................2Battery Charge Current ....................................................36Battery Failure Report Code ............................................29Battery, Backup  .................................................................2Beep On Exit Delay  .........................................................24Beep On Trouble  .............................................................37Bell Cut-Off Timer ............................................................25Bell on Communication Failure ........................................32Bell OutputConnection ....................................................................4Disconnected Report Code ...........................................29Overload Report Code ..................................................29Bell Squawk On Arm/DisarmWith Keypad ................................................................24With Remote Control ....................................................24Burglary Zones, 24 Hr. .....................................................14Buzzer Zone  ....................................................................14Bypass Options, Supervision ...........................................39Bypass Programming  ......................................................44Bypass Recall Feature .....................................................45Bypass Zones ..................................................................16CCall Back Feature  ............................................................41Call Upload/Download Software ......................................38Call WinLoad Software  ....................................................40Cancel Auto-Arm Report Code ........................................28Cancel Communication ....................................................38Charge Current ................................................................36Check-in Supervision .......................................................19Chime Zones  ...................................................................46Clock Adjust .....................................................................36Closing Delinquency ........................................................33Report Code ................................................................28Cold Start Report Code  ...................................................30Configuring The LED Keypads  ..........................................8ConnectingBells or Sirens ...............................................................4Fire Zones .....................................................................6Keypad Zones ...............................................................5Keypads ........................................................................5Keyswitches ..................................................................6PGMs ...........................................................................4Single Zone Inputs .........................................................5Telephone Lines ............................................................4Contact ID Options  ..........................................................31Counter, Auto Zone Shutdown ........................................16Current Consumption Table ...............................................4DData Display Mode  ............................................................7DelayBefore Alarm Report Code Transmission ........................17Between Dialing Attempts .............................................33Dial Tone ....................................................................32Pager Report ...............................................................32Power Failure Report ....................................................33Delayed Fire Zone  ...........................................................15Dial Tone Delay  ...............................................................32Dialer settings ..................................................................27Dialing Attempts ...............................................................33Dialing Method .................................................................32Disarm Reporting Options  ...............................................33Disarming .........................................................................43Duress Code ....................................................................11Duress Report Code ........................................................29
50   Reference & Installation Manual   EEmergency Panic Report Code ....................................... 29Entry Delay ...................................................................... 14EOL Zones  ...................................................................... 17Event Buffer Transmission  .............................................. 41Event Call Direction ......................................................... 32Exclusive Zone DefinitionsDelayed Fire Zone .......................................................15Keyswitch Zone ........................................................... 14Standard 24Hr. Fire Zone ............................................. 15Exit Delay  ........................................................................ 24Expansion Input ............................................................... 12FFail to Communicate Report Code  .................................. 29Feature Select Programming Method ................................ 7Features, Wireless ........................................................... 18Fire Circuits  ....................................................................... 6Fire Loop Trouble Report Code ....................................... 29Fire Panic Report Code ................................................... 29Fire ZoneDelayed ...................................................................... 15Standard 24 Hr. ........................................................... 15Wireless ...................................................................... 15Follow Zones  ................................................................... 14Force Arming ................................................................... 44Force Zones  .................................................................... 17GGlobal PGM ..................................................................... 34Ground ...............................................................................2HHardware Reset ............................................................... 36IInput Speed  ..................................................................... 17Installation ......................................................................... 2InstallerCode .......................................................................... 10Lock ...........................................................................36Quick Functions Keys ................................................... 38Test Mode ................................................................... 38Installer In Report Code ................................................... 30Installer Out Report Code ................................................ 30Instant Arming  .................................................................44Intellizone ........................................................................ 16KKey. See Memory CardKeypadAudible Trouble Warning ..............................................37Backlight ..................................................................... 46Installation .....................................................................5Lockout Report Code .................................................... 29Muting ........................................................................ 46Panic Options .............................................................. 26Tamper Supervision ..................................................... 37Zone Connection ........................................................... 5KeyswitchArming ........................................................................ 45Arming, Report Code .................................................... 28Connections .................................................................. 6Disarming Report Code ................................................ 28Options ....................................................................... 17Zone ........................................................................... 14LLate to Close Report Code .............................................. 28Length of Access Codes .................................................. 10Location and Mounting  ...................................................... 2Lock Master Code  ........................................................... 11Lock-out ........................................................................... 36MManual Bypass Programming  ......................................... 44Maximum Dialing Attempts .............................................. 33Memory Card ..................................................................... 9Memory Display ............................................................... 46Module Fault Report Code  .............................................. 29Mounting ............................................................................ 2Multiple Feature Select Programming Method  .................. 7Muting .............................................................................. 46NNo ArmingOn Battery Fail ............................................................ 23On Supervision Loss .................................................... 39On Tamper Trouble ...................................................... 23No Audible Feedback Upon Stay Arming ........................ 25No Exit Delay When Arming with Remote Control  .......... 24No Movement Auto-Arming  ............................................. 23No Movement Report Code ............................................. 28Number of Rings .............................................................. 40OOne-Touch Arming  .................................................... 24, 45Report Code ................................................................ 28OptionsAlarm .......................................................................... 25Arming and Disarming .................................................. 22Auto-Arming ................................................................ 24Keyswitch ................................................................... 17User code ................................................................... 10Zone ........................................................................... 16Override Answering Machine  .......................................... 40PPagerDelay .......................................................................... 32Format Transmission Options ........................................ 31Reporting Format ......................................................... 31Panel Answer Options ..................................................... 40Panel Identifier ................................................................. 40Panic Alarms  ................................................................... 45Panic Options  .................................................................. 26
Spectra Series   51Partial Arming Report Code .............................................28Partition Account Numbers  ..............................................30Partition Assignment, Zone ..............................................15Partitioning .......................................................................36PC Exit Report Code  .......................................................30PC Password ...................................................................40PC Telephone Number ....................................................40PGM (Control Panel)Activation Event ...........................................................34Deactivation Event .......................................................35PGM Delay ..................................................................35Strobe Options .............................................................35PGM Activation, User Code Option  .................................11Power .................................................................................2Power Failure Report Delay .............................................33Printer Fault Report Code ................................................29Programmable Output Connections  ..................................4Programmable Outputs ....................................................34ProgrammingAccess Codes ..............................................................43Chime Zones ...............................................................46Methods ........................................................................7Using a Keypad .............................................................7Wireless Features ........................................................18Wireless Fire Zone .......................................................15Pulse Ratio  ......................................................................32QQuick Arming  ...................................................................24Quick Functions Keys (Installer)  ......................................38RReal-Time Clock  ..............................................................36Reassign Zones to Expansion Inputs  ..............................13Recall Bypass ..................................................................45Recent Close Delay .........................................................33Recent Closing Report Code ...........................................29Recycle Alarm ..................................................................25Regular Arming ................................................................44Regular Arming Switches to Force Arming ......................23Remote Arming Report Code  ..........................................28Remote ControlsAssigning to 1759EX ....................................................20Assigning to User Access Codes ...................................21Deleting ......................................................................20Programming ...............................................................20Programming Remote Control Buttons ...........................21Remote Disarm Report Code  ..........................................28Report Code, SpecialCold Start ....................................................................30Installer In ...................................................................30Installer Out .................................................................30PC Exit ........................................................................30Test Report .................................................................30Tx Supervision Loss .....................................................30Tx Supervision Restore .................................................30Report Code, Special AlarmAuto Zone Shutdown ....................................................29Auxiliary Panic .............................................................29Duress ........................................................................29Emergency Panic .........................................................29Fire Panic ....................................................................29Keypad Lockout ...........................................................29Recent Closing ............................................................29Report Code, Special ArmingClosing Delinquency .....................................................28Keyswitch Arming .........................................................28Late to Close ...............................................................28No Movement ..............................................................28One-Touch Arming .......................................................28Partial Arming ..............................................................28Remote Arming ............................................................28Timed Auto-Arming ......................................................28Report Code, Special DisarmingCancel Auto-Arm ..........................................................28Keyswitch Disarming ....................................................28Remote Disarm ............................................................28Report Code, System TroubleAC Failure ...................................................................29Auxiliary Supply ...........................................................29Battery Failure .............................................................29Bell Output Disconnected ..............................................29Bell Output Overload ....................................................29Fail to Communicate .....................................................29Fire Loop Trouble .........................................................29Module Fault ................................................................29Printer Fault .................................................................29Timer Loss ..................................................................29Wireless Low Battery ....................................................29Report Codes ...................................................................28Reporting and Dialer settings  ..........................................27Reporting Formats ...........................................................30Re-Program All Expansion Modules ................................39Reset, Hardware ..............................................................36Restrict ArmingOn Battery Fail .............................................................23On Supervision Loss ....................................................39On Tamper Trouble ......................................................23Rings ................................................................................40SSingle Zone Inputs .............................................................5Software, Upload/Download  ..............................................7Special Alarm Report Codes  ...........................................29Special Arming Report Codes  .........................................28Special Disarming Report Codes .....................................28Special Reporting Codes .................................................30Standard 24Hr. Fire Zone ................................................15StayArming ........................................................................44Delay ..........................................................................22Zones .........................................................................16Strobe Options .................................................................35Supervision Bypass Options ............................................39Supervision Options, Wireless Transmitter ......................39Switch to Stay Arming ......................................................22SystemMaster Code ................................................................10Real-Time Clock ..........................................................36Settings .......................................................................36Trouble Report Codes ..................................................29
52   Reference & Installation Manual   Trouble Restore Codes ................................................. 30TTamper Bypass Options .................................................. 26Tamper Recognition  ........................................................ 25Telephone Line Connection ............................................... 4Telephone Line Monitoring (TLM) ................................... 34Telephone Number, PC ................................................... 40Telephone Numbers ........................................................ 30Test ReportAutomatic .................................................................... 33Manual ....................................................................... 38Report Code ................................................................ 30Timed Auto-Arming .......................................................... 23Report Code ................................................................ 28Timer ............................................................................... 33Timer Loss Report Code  ................................................. 29Transformer Requirements ................................................ 2Transmission Options, Pager Format .............................. 31Trouble Display ................................................................ 42Tx SupervisionLoss Report Code ........................................................ 30Restore Report Code .................................................... 30UUpload/Download Software ............................................... 7User Code OptionsArm Only ..................................................................... 11Bypass Programming ................................................... 11Force Arming ...............................................................11Partition 1 Assignment .................................................. 10Partition 2 Assignment .................................................. 11PGM Activation ............................................................ 11Stay Arming ................................................................ 11User Operation  ................................................................ 42WWinload Software  .............................................................. 7Wireless Features ............................................................ 18Wireless Fire Zone Programming .................................... 15Wireless Low Battery Report Code ................................. 29Wireless TransmittersAssigning .................................................................... 18Check-in Supervision .................................................... 19Check-in Supervision Timer Settings .............................. 20Deleting ......................................................................18Low Battery Supervision ......................................... 20, 39Programming ............................................................... 18Serial Number Display .................................................. 19Supervision Options ..................................................... 39Viewing Signal Strength ................................................ 19ZZone Alarm Report Codes ............................................... 28Zone Alarm Restore Report Codes  ................................. 29Zone Definitions24Hr. Burglary Zones ................................................... 1424Hr. Buzzer ............................................................... 14Entry Delay 1 ............................................................... 14Entry Delay 2 ............................................................... 14Follow Zones ............................................................... 14Instant Zones .............................................................. 14Zone OptionsAlarm Types ................................................................ 16Auto Zone Shutdown .................................................... 16Delay Before Alarm Report Code Transmission ............... 17Force Zones ................................................................ 17Intellizone ................................................................... 16Keyswitch Options ....................................................... 17Stay Zones .................................................................. 16Zone Partition Assignment  .............................................. 15Zone Programming .......................................................... 12Zone Restore Report Options .......................................... 34Zone Shutdown, Auto ...................................................... 16Zone Speed ..................................................................... 17Zone TamperReport Codes .............................................................. 29Restore Report Codes .................................................. 29Zones OptionsBypass Zones .............................................................. 16
Notes
For technical support in Canada or the U.S., call 1-800-791-1919 for English or 1-866-912-0600 for French, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST. For technical support outside Canada and the U.S. call 00-1-450-491-7444, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST. Please feel free to visit our website at www.paradox.ca.780 Industriel Blvd., Saint-Eustache (Quebec) J7R 5V3 CANADATel.: (450) 491-7444                                      Fax: (450) 491-2313www.paradox.caPRINTED IN CANADA 09/2004                                        1759MG-EI05

Navigation menu