Paradox Security Systems DCTXP2 Door Contact Wireless Detector User Manual DCTXP2 TI09 new format

Paradox Security Systems Door Contact Wireless Detector DCTXP2 TI09 new format

Users Manual

DCTXP2-EI09 08/2018 paradox.comDCTXP2Wireless 2-Zone Door ContactInstallation Manual (V3.0/4.0)IntroductionThe DCTXP2 can support two inputs simultaneously (reed switch & universal input). It transmits two different serial numbers (SN), one for each input, which are always SN and SN+1 (e.g., 240 000 & 240 001). A switch or other security device can be connected to the universal transmitter input terminals to provide wireless transmission of the device's open/closed status. Compatibility • MG5000, MG5050, MG6250• EVO192 and EVOHD with a RTX3• SP4000, SP5500, SP6000, SP65, and SP7000 with a RX1Location and MountingThere should be at least 30cm (1ft) between each transmitter and 1.5m (5 ft) between the transmitters and the receiver. Please refer to the table below for magnet distances depending on the surface of installation.Testing the Unit1. Perform a signal strength test before finalizing installation. If the transmission is weak, relocate the transmitter by a few inches to improve reception.2. Verify that the batteries are inserted properly.3. Assign the door contact to a Magellan receiver.4. Open and close the assigned door/window to verify proper operation.Configurations Axis Removal Distance Approach DistanceWood X 2 cm (0.78 in) 1.4 cm (0.55 in)Y 2.8 cm (1.10 in) 2.7 cm (1.06 in)Z 3.6 cm (1.41 in) 3.2 cm (1.25 in)Iron X 2.3 cm (0.90 in) 1.5 cm (0.59 in)Y 2.4 cm (0.94 in) 1.9 cm (0.74 in)Z 3.2 cm (1.25 in) 2.9 cm (1.14 in)Do not cut, bend or alter the antenna. Avoid mounting the door contact near or on metal as this may affect transmission.JumpersJP1 ONNormally OpenReed Switch/Universal Input:open = “zone open” signalclosed = “zone closed” signalJP1 OFFNormally ClosedReed Switch/Universal Input:open = “zone closed” signalclosed = “zone open” signal            JP2 NOT USEDLearn ModeLearn Mode allows you to transmit the serial numbers of each input. To enter Learn Mode, open the cover and wait until the LED stops flashing. Anti-Tamper SwitchSerial NumberVisual ConfirmationPress and release the anti-tamper switch once.SN = Reed switch(e.g. 240 000)The LED will flash once four times.Press and release the anti-tamper switch twice within one second.SN+1 = Universal transmitter input(e.g. 240 001)The LED will flash twice rapidly four times.Powering the UnitVerify proper polarity and insert two alkaline “AAA” batteries. After inserting batteries, a power up sequence will begin (10-20 seconds) during which the door contact will not detect an open zone or tamper.Replacing the BatteriesTo replace batteries:1. Remove the old batteries.2. Press and release the anti-tamper switch several times.3. Wait 60 seconds to reinitialize the unit.Low Battery The door contact performs a battery test every 12 hours. If the voltage is below 2.3V after four consecutive battery tests (48 hrs.), the red LED will flash at 5 second intervals and the DCTXP2 will transmit a low battery signal. A low battery signal will be sent for battery voltage below 2.3V.AAAAAA JP2JP1
DCTXP2-EI09 08/2018 paradox.comTamperIn order to secure the tamper screw you must first remove the PCB of the DCTXP2.Technical SpecificationsSpecifications may change without prior notice. †For the latest information on product approvals visit our website at www.paradox.com. *The warranty does not apply to the batteries provided with the unit.** Battery life depends on the traffic through the protected zone.Changes or modifications on equipment not expressly approved by Paradox could void the user's authority to operate the equipment.FCC and Industry Canada Compliance StatementThis device complies with FCC Rules Part 15 and with Industry Canada license exempt RSS standard(s). Operation is subject to two conditions:1. This device may not cause harmful interference2. This device must accept any interference that may be received or that may cause undesired operation.Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : 1. l'appareil ne doit pas produire de brouillage, et 2. l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.This Class B digital apparatus complies with Canadian ICES-003.Cet appareil numerique de la classe B est conforme a la norme NMB-003 du Canada.FCC ID: KDYDCTXP2CANADA: 2438A-DCTXP2FCC WARNINGThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:· Reorient or relocate the receiving antenna.· Increase the separation between the equipment and the receiver.· Connect the equipment into an outlet different from that to which the receiver is connected.· Consult the dealer or an experienced radio/TV technician for help.Reed switch w/magnet One (high sensitivity) with a standard gap of 1cm (0.4”) from magnetInput Response Time 45 ms RF frequency 433 MHz or 868 MHzCurrent consumption 25 µA Standby / 5 mA AlarmPower 3.0 Vdc (Two “AAA” Alkaline batteries)* Low Battery 2.3 VDCType of power supply Type CBattery life Up to three years**  Range (typical in a residential environment)MG/SP Series, RTX3, and RCV3: 60m (200 ft) Magellan Console: 30m (100ft)Spectra 1759MG: 45m (150ft)Anti-tamper switch YesCompatibility MG5000/MG5050, Any Spectra SP Series panel, EVO192, EVOHD, MG6130/MG6160, RTX3Dimensions 11 X 3.2 X 2.5 cm (4.4 X 1.3 X 1.0in)Operating temperature -10°C to 55°C (14°F to 131°F)Certification EN 50131-2-6, EN 50131-6Security Grade 2 Environmental Class IIApprovals† FCC, IC, and ETL approvals are valid for 433 MHz only CWarrantyFor complete warranty information on this product please refer to the MG-6060/MG-6030 reference manuals, together with the Limited Warranty Statement found on the website www.paradox.com/terms. Your use of the Paradox product signifies your acceptance of all warranty terms and conditions.PatentsUS, Canadian and international patents may apply. Paradox is a trademark or registered trademark of Paradox Security Systems (Bahamas) Ltd. © 2018 Paradox Security Systems Ltd.

Navigation menu