Paradox Security Systems MG6160 Wireless Console User Manual MAGELLAN MG 6160 MG 6160 Installation Manual
Paradox Security Systems Wireless Console MAGELLAN MG 6160 MG 6160 Installation Manual
Contents
- 1. User Manual 1
- 2. User Manual 2
- 3. user Manual 3
User Manual 1
All-In-One Wireless Security System V2.0 Model #: MG-6130 / MG-6160 Reference and Installation Manual We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us your comments. Table of Contents Introduction................................................... 3 About Magellan and this Manual............................. 3 Conventions ............................................................ 3 Specifications.......................................................... 3 Quick Setup................................................... 4 Installation..................................................... 7 AC Power................................................................ 7 DC Power................................................................ 7 Backup Battery Pack............................................... 7 Auxiliary Output....................................................... 7 Telephone Line Connections .................................. 8 Programmable Outputs (PGMs) ............................. 8 Hardwire Zone Connections ................................... 9 WinLoad Connection............................................. 10 UIP-256 Universal In-Field Programmer Connection. 10 X10 Transmitter Connection (MG-6160 only) ....... 10 Connecting a Paradox Memory Key (PMC-3)....... 10 Location and Mounting.......................................... 11 Connecting the Radio Antenna (MG-6160 only) ... 12 Programming Methods .............................. 13 WinLoad Installer Upload/Download Software...... 13 Programming Using the Built-in Keypad ............... 13 Programming Using a Paradox Memory Key........ 13 User Codes.................................................. 14 User Code Length................................................. Installer Code........................................................ Maintenance Code................................................ System Master Code ............................................ Duress Code ......................................................... 14 14 14 14 14 Zone Programming..................................... 15 Zone Programming Overview ............................... Zone Definitions .................................................... Zone Options ........................................................ Zones 31 and 32 Become Hardwire Zones .......... EOL (End-Of-Line) Zones ..................................... Assigning Wireless Zone Transmitters ................. Assigning Wireless Doorbells to the Console ....... Deleting Assigned Wireless Transmitters ............. Viewing Wireless Transmitter Signal Strength...... Assigning Remote Controls .................................. Programming the Remote Control’s Buttons ........ Assigning Wireless Keypads................................. Assigning Wireless Repeaters .............................. Wireless Repeater Options ................................... 15 15 17 18 18 19 19 19 19 20 20 21 21 21 Arming and Disarming ............................... 22 Regular Arming Switches to Stay Arming ............. 22 Paradox Magellan Systems Regular Arming Switches to Force Arming ........... Stay Arming Switches to Force Arming................. Timed Auto-Arming ............................................... No Movement Auto-Arming................................... Auto-Arming Options............................................. One-Touch Arming................................................ Exit Delay .............................................................. Bell Squawk on Arm/Disarm with Remote Control No Exit Delay when Arming with Remote Control. Exit Delay Termination .......................................... Follow Zone Switches to Entry Delay 2................. Closing Delinquency Timer ................................... Stay Arm Siren Delay............................................ 22 22 22 22 23 23 23 23 23 23 23 23 23 Alarm Options............................................. 24 Bell Cut-off Timer .................................................. 24 Wireless Transmitter Supervision Options ............ 24 Check-in Supervision Options............................... 24 Tamper Recognition Options ................................ 24 Wireless PGM Supervision Options ...................... 25 Wireless Keypad Supervision Options .................. 25 Wireless Repeater Supervision Options ............... 25 Wireless PGM Console Supervision Options (Follow Alarm/Follow Bell) ................................................. 25 Backup Alarm Reporting Option............................ 25 Panic Alarms ......................................................... 26 Reporting and Dialer Settings................... 27 Report Codes ........................................................ Console Telephone Numbers ............................... Console Account Number ..................................... Reporting Formats ................................................ Event Call Direction............................................... Delay Between Dialing Attempts........................... Alternate Dial Option ............................................. Force Dial Option .................................................. Dialing Method ...................................................... Pulse Ratio............................................................ Switch to Pulse Dialing on 5th Attempt ................. Telephone Line Monitoring (TLM) ......................... Recent Close Delay .............................................. Auto-Test Report................................................... Power Failure Report Delay .................................. Disarm Reporting Options..................................... Zone Restore Report Options ............................... RF Jamming Supervision ...................................... 27 29 30 30 31 31 31 31 32 32 32 32 32 32 33 33 33 33 Programmable Outputs ............................. 34 Assigning PGMs.................................................... 34 Setting PGM Function ........................................... 34 Onboard PGM Activation Event ............................ 34 Onboard PGM Deactivation Event ........................ 34 Onboard PGM Delay............................................. 34 PGM Normal State (Onboard Only) ...................... 35 PGM X10 Option (MG-6160 Only / Onboard Only) 35 Wireless PGM Activation Event ............................. 35 Wireless PGM Deactivation Event......................... 35 Wireless PGM Delay.............................................. 35 System Settings .......................................... 36 Software Reset ...................................................... 36 Installer Lock.......................................................... 36 Console Tamper Supervision ................................ 36 Console Audible Trouble Warning ......................... 36 FM Tuner Option (MG-6160 only).......................... 36 Daylight Savings Time ........................................... 36 AC Power Failure Warning .................................... 36 The Trouble Display............................................... 36 WinLoad Software Settings ....................... 38 Panel Answer Options ........................................... 38 Panel Identifier....................................................... 38 PC Password ......................................................... 38 PC Telephone Number .......................................... 38 Call Back Feature .................................................. 38 Appendix 1: Automatic Report Code List. 39 Appendix 2: Ademco Contact ID Report Code List ............................................................... 41 Index ............................................................ 44 Reference & Installation Manual Introduction About Magellan and this Manual Specifications Magellan is designed for fast and easy installation. Simply remove it from the box, mount the console and wireless transmitters, apply power, perform some basic programming and Magellan is ready to protect your home. Power input: AC*: 12Vac, 1A transformer or 16.5Vac, 1A transformer or DC: 12Vdc to 18Vdc (1A) power supply Some of Magellan’s features can be programmed through a quick Installer menu (menu programming) or through section programming. Use the quick setup chapter (see page 4) to install the Magellan console quickly with the basic programming required for a standard security application. All other chapters (pages 7 to 38) are for advanced section programming. These other chapters provide more in-depth and precise information if more advanced programming is required. or For UL installations: Primary: 120Vac, 60Hz, 120mA Secondary: 16.5Vac, 60Hz, 600mA Current consumption: 1A max. (600mA max. for UL installations) We recommend that you read this entire manual before you begin your installation. Auxiliary output: When using an AC or DC power source, the auxiliary output provides 13.8V (200mA maximum). To achieve this value, use a minimum of 15Vdc. Conventions This symbol designates a reference to another section, manual or guide. Backup Battery: 7.2Vdc, 1.8Ah NiMH rechargeable battery pack (order # 0780100178) Not user replaceable. Replace battery every 35 years. This symbol designates either a warning or important information. PGM1: N.O solid-state relay (not polarized); Internal resistance 16 9max.; Max. handling current 100mA. PGM2: One low powered open-collector; Max. handling current 50mA. This symbol designates a reminder or suggestion. [DATA] = - Text shown in this manner designates data or programming information that is entered through the console’s keypad. - Text shown in this manner can also designate a specific key that has to be pressed. * It is recommended that you use a 12Vac, 1A transformer to power the Magellan console. The console will generate less heat when connected to a 12Vac transformer than when connected to a 16.5Vac transformer. In UL installations, use only the Universal transformer (model no. UB1640W, 16.5Vac, 40VA). The alternate DC power supply is not for use in UL installations. Grade A Household Fire and Burglar Alarm Warning System Unit. Paradox Magellan Systems Quick Setup Follow these steps to quickly set up Magellan with the required settings for a basic security installation. Profile” menu or press the [6] key to immediately access the “Zone Profile” menu. For more in-depth programming of the console’s communication features, see Reporting and Dialer Settings on page 27. 1.Getting Started 1. After powering up for the first time, the language selection option will appear. Select the desired language. 2. Press [START] to access the Installer menu. 4.Adding and Programming Zones 1. From the “Zone Profile” menu, press [OK]. 2. Select which zone you wish to add by pressing [NEXT] and press [OK] when the desired zone number appears. 2.User Programming 1. From the “User Profile” menu, press [OK]. 2. Select which user you wish to add by pressing [NEXT]. When the desired user appears, press [OK] and follow the menus to set: - Access code - User label - Remote control When you are done the next menu option will appear (see Monitoring Station Reporting below). For more in-depth programming of the remote controls, see Programming the Remote Control’s Buttons on page 20. 3. Press the tamper switch on the transmitter you wish to assign to the selected zone. Follow the menus to set: - Zone Label - Zone Type - Other Zones When you are done the next menu option will appear. Press [NEXT] until you see the “System Test” menu or press the [5] key to immediately access the “System Test” menu. For more in-depth programming of the console’s zones, see Zone Programming on page 15 and When hardwired zones are used, the EOL Resistor Option must be enabled for UL installations.Wireless Programming on page 18. 5.Testing the Magellan System 1. From the “System Test” menu, press [OK]. 3.Monitoring Station Reporting 1. From the “Communicator” menu, press [OK]. 2. Press [OK] and follow the menus to set: - Telephone numbers - Account Number - Report Format When you are done the next menu option will appear. Press [NEXT] until you see the “Zone 2. Select which test you wish to perform by pressing [NEXT] and press [OK] when the desired test appears. The following tests can be performed: - Zone tests - Remote control tests - Reporting tests - Hardware tests Reference & Installation Manual WARNING! When testing the hardware, the speaker and sirens will also be tested. Avoid close proximity to the Magellan console when performing the hardware test to avoid any damage to your hearing. 8.Time and Date 1. Press the [MENU] key. When you are done the next menu option will appear. Press [NEXT] until you see the “Passwords” menu or press the [8] key to immediately access the “Passwords” menu. 2. Press [NEXT] until you reach the “Time and Date” menu and press [OK] or press the [3] key to access the “Time and Date” menu. 6.Signal Strength 1. From the “Signal Strength” menu, press [OK]. 3. Select the time format (12Hrclock or 24Hr-clock) and then program the time. Press [OK] when done.Program the date by entering the 4-digit year first, followed by the 2-digit month and then the 2-digit day. Press [OK] when done. 2. The Magellan will begin testing the noise level and signal strength of all assigned wireless transmitters. Press [NEXT] to navigate through the various tests. Press [EXIT] when you are done. Deleting Zones 7.Passwords 1. From the “Passwords” menu, press [OK]. 2. Select which password(s) or code(s) you wish to program by pressing [NEXT] and press [OK] when the desired password appears. The following passwords can be programmed: - Installer code - Maintenance code - Panel ID - PC Password When you are done the next menu option will appear. Press [EXIT]. For more in-depth programming of the console’s passwords, see User Codes on page 14 and WinLoad Software Settings on page 38. 1. From the “Zone Profile” menu, press [OK]. 2. Select which zone you wish to delete by pressing [NEXT] and press [OK] when the desired zone number appears. 3. Press [YES]. 4. Press [YES]. To delete another zone, press [YES] and then repeat steps 2 to 4. When you are done the next menu option will appear. Press [NEXT] until you see the “System Test” menu or press the [5] key to immediately access the “System Test” menu. For more in-depth programming of the console’s zones, see Zone Programming on page 15 and When hardwired zones are used, the EOL Resistor Option must be enabled for UL installations.Wireless Programming on page 18. Paradox Magellan Systems Adding Outputs 1. From the “Output Profile” menu, press [OK]. 2. Select which output you wish to add, modify or delete by pressing [NEXT] and then [OK] when the desired output number appears. 3. Select what type of output you wish to add. Press [YES] for a wireless output, or [NO] for a hardwired output. For hardwired, follow the menus to configure the output. 4. If you are adding a wireless output, press the tamper switch on the transmitter you wish to assign to the selected zone. When you complete an output programming option, you will be given the choice to configure another output. If you do not choose to program another output, you will be brought back to the “Output Profile” menu. Deleting Outputs 1. From the “Output Profile” menu, press [OK]. 2. Select which output you wish to delete by pressing [NEXT] and then [OK] when the desired output number appears. 3. Press [YES]. 4. Press [YES]. To delete another output press [YES] and then repeat steps 2 to 4. When you are done the next menu option will appear. Press [NEXT] until you see the “System Test” menu or press the [5] key to immediately access the “System Test” menu. Reference & Installation Manual Installation AC Power Backup Battery Pack Magellan requires a 12Vac (1A) or 16.5Vac (1A) transformer (not included) to supply power to the console. Connect the transformer to the AC terminals as shown in Figure 1 on page 7. Magellan uses a backup battery pack to provide power during a power loss. A 7.2Vdc 1.8Ah NiMH (Nickel Metal Hydride) rechargeable battery pack is included with the Magellan console. Connect the battery pack as shown in Figure 3 on page 7. Magellan can also be powered through a DC power supply. Connect a 12Vdc to 18Vdc (1A) power supply to the AC terminals to power the console. The alternate DC power supply is not for use in UL installations. Do not connect to a receptacle controlled by a switch. Connect the backup battery pack after applying AC power. Figure 3: Connecting the Backup Battery Back view of the Magellan console Figure 1: Connecting the Transformer Back view of the Magellan console. Do not use any switch-controlled outlets. 1. Insert the backup battery’s plug into the connector labeled BATT. 2. Slide in the battery pack horizontally, tilt the battery pack downward and then tuck it in Magellan’s battery compartment. 12Vac (1A) to 16Vac (1A) transformer Insert the transformer’s wires into the AC terminals. 3. Snap in the battery compartment cover when finished. To order a battery pack, the battery pack’s part number is: Paradox# 0780100178. DC Power Magellan can also be powered through a DC power supply. Connect a 12Vdc to 18Vdc (1A) power supply to the AC terminals to power the console. Connect the transformer to the AC terminals as shown in Figure 2 on page 7. Figure 2: Connecting the DC Power Supply Back view of the Magellan console. The backup battery can support Magellan during an AC failure for 24 hours when in standby mode. Auxiliary Output The auxiliary power supply terminals can be used to power motion detectors. The combined current consumption of devices connected to the auxiliary power supply should not exceed 200mA. If the auxiliary output is overloaded and is shut down, you must disconnect all loads from the output for at least 10 seconds before reconnecting any load back to the auxiliary output. Insert the transformer’s wires into the AC terminals. DC Power Supply 12Vdc to 18Vdc 1A Paradox Magellan Systems Figure 4: Auxiliary Output Connection Devices such as a light, etc. Insert the device’s wires into the AUX AND C terminals. Telephone Line Connections The Magellan console can be connected to a telephone line by connecting the telephone company’s wires directly to Magellan’s dialer or by connecting a standard 4-pin RJ-11 cable between the LINE plug of the console to a standard telephone wall jack. Direct Connect Connect the telephone line through a RJ31X jack as shown in Figure 5 on page 8. Figure 5: Telephone Line Direct Connect Line Plug Connect The Magellan console can also be connected to a telephone line via its on-board LINE plug. See Figure 6 on page 8 for more information on connecting the telephone line using this method. When connecting via the LINE plug, if the telephone line is shared and it is busy (i.e. someone is talking on the telephone) the console will be unable to communicate with the Monitoring Station. It is recommended that the Direct Connect method (see page 8) be used to connect the telephone line. Figure 6: Line Plug Connection Back view of the Magellan console. Back view of the Magellan console. 4-pin RJ-11 cable To connect the telephone line: 1. Connect a RJ31X to the R1, T-1, RING and TIP terminals as shown at right. 2. Connect the telephone company wires and the home telephone to the RJ31X. For UL compliant installations, the Magellan console must be able to seize the telephone line and place a call in a nonmedical emergency situation. It must be able to do this even if other equipment (telephones, answering machines, computer modems, etc.) already has the line in use. To do so, the Magellan console must be connected to a properly installed RJ31X jack that is in series with and ahead of all other equipment attached to the same telephone line. Proper installation is depicted in the diagram below. If you have any questions concerning these instructions, you should consult your telephone company about installing the RJ31X jack and the Magellan console for you. 1. Insert one end of the 4-pin RJ-11 cable into the LINE plug of the Magellan console. 2. Insert the other end of the RJ-11 cable into a standard telephone wall plug. Programmable Outputs (PGMs) Magellan comes equipped with one 100mA solid-state PGM output and one low powered open-collector; Max. handling current 50mA. When a specific event occurs in the system, a PGM can be programmed to activate lights, garage door openers, etc. See Programmable Outputs on page 34 for more information on programming PGMs. Connect Magellan’s PGM outputs as shown in Method 1 in Figure 7 on page 9. Since Magellan does not come with a power supply, an external power supply must be employed to power the circuit. The PGM outputs can be either Normally Open (N.O.) or Reference & Installation Manual Normally Closed (N.C.) as detailed in PGM Normal State (Onboard Only) on page 35. Hardwire Zone Connections If the current draw on the PGMs is to exceed 100mA, we recommend using an external relay as shown in Method 2 in Figure 7 on page 9. For connecting PGM2, see Figure 8. Magellan comes with two on-board hardwire zones. You can connect hardwire detection devices such as door contacts to Magellan’s zone terminals. Connect the detection devices as shown in Figure 9 on page 9. Please note the following: Using Method 2, connect the device to the output terminal of the external relay that matches the normal state of Magellan’s PGM output. For example, if PGM1’s normal state is Normally Open (N.O.), connect the device to the N.O. terminal of the external relay. • • Figure 7: PGM1 Connections Back view of the Magellan console. Method 1 (less than 50mA) • Section [095] options [1] and [2] must be enabled in order to use the two on-board hardwire zones. See Zones 31 and 32 Become Hardwire Zones on page 18 for more information. After connecting the detection devices, the zones must be defined. See Zone Programming on page 15 for more information. The hardwire zones follow the console’s EOL and tamper definitions. Though any hardwire detection device can be connected to Magellan’s on-board hardwire zone inputs, it is recommended that only devices that do not require a power source (i.e., standard door contacts) be connected. Since Magellan has no power supply, an external power supply would have to be connected in order to power hardwire detection devices that do require a power source. Method 2 (> 50mA) External DC Power Supply Devices such as a light, etc. Figure 9: Hardwire Zone Connections Devices such as a light, etc. External relay External DC Power Supply Figure 8: PGM2 Connections Back view of the Magellan console. Method 2 (exceeds 100mA) External relay Method 1 (less than 100mA) External DC Power Supply Devices such as a light, etc. Devices such as a light, etc. External DC Power Supply Paradox Magellan Systems Figure 11: Connecting the UIP-256 WinLoad Connection The Magellan console can be programmed and monitored through the WinLoad Installer Upload/Download Software for Windows®. WinLoad allows for remote or on-site uploading and downloading using most standard modems. It also allows for advanced printing of reports and supports several languages simultaneously. Connect Magellan to a computer containing the WinLoad software as shown in Figure 10 on page 10. Refer to the WinLoad’s Online Help for more information on WinLoad. Figure 10: On-site Connection Connect the 10-pin cable of the UIP-256 to the 10-pin connector of the Magellan console. Back view of the Magellan console. UIP-256 Universal In-Field Programmer Back view of the Magellan console. Standard DB-9 cable (9-pin serial cable) Download latest Magellan firmware from paradox.com X10 Transmitter Connection (MG-6160 only) 4-pin connector cable 4- to 10-pin cable (supplied with the 306 Adapter) 306 Adapter Computer containing WinLoad software Magellan supports the X10 communication protocol. X10 is a communication protocol for remote control of electrical devices such as lamps and appliances. Communication is accomplished through standard household electrical wiring using X10 transmitters and receivers. Configure Magellan, with the use of an X10 transmitter, to automate a home. Connect the X10 transmitter as shown in Figure 12 on page 10. Refer to the Magellan X10 Instructions on our website, paradox.com, for information on using and configuring Magellan’s X10 feature. Standard DB-9 cable (9-pin serial cable) Figure 12: Connecting the X10 Transmitter Back view of the Magellan console. UIP-256 Universal In-Field Programmer Connection 1. Connect one end of the 4-pin RJ11 cable into the X10 plug of the console. 2. Connect the other end of the 4-pin RJ11 cable into the X10 transmitter. Magellan’s firmware can be upgraded locally using the UIP-256 Universal In-Field Programmer. The UIP-256 includes proprietary PC software, cables to interconnect Magellan and a PC, as well as two 9V batteries. Connect the UIP-256 as shown in Figure 11 on page 10. 3. Plug the X10 transmitter into a standard wall outlet. Refer to the Universal In-Field Programmer (UIP-256) Instructions for more information. 4-pin RJ11 cable X10 transmitter The X10 feature is not for use in UL installations. Connecting a Paradox Memory Key (PMC-3) When using a Paradox Memory Key with a Magellan console, remove power (both AC and battery power) and connect the memory key to the 5-pin connector on the back of the Magellan console as shown in Figure 13 on page 11. Once connected, re10 Reference & Installation Manual apply power to the console. For more information, see Programming Using a Paradox Memory Key on page 13. Figure 14: Wall Plate Figure 13: Connecting a Paradox Memory Key (PMC-3) A (x7) Figure 15: Mounting Magellan onto the Wall Plate Jumper ON: Read from and/or write to memory key Jumper OFF: Write protected (read from memory key only) The installer should verify the proper installation of the memory key. Location and Mounting Location The locations of Magellan and its wireless transmitters affect the overall performance of the wireless system. To ensure the best signal reception, the following list of location criteria should be respected whenever possible: • • • • • • Select an installation site that is free of obstacles that reflect and absorb radio frequency (RF) signals, as well as interference that may distort signals. Avoid installation near or in the path of strong RF fields (i.e., neon lights, computers), and on or near metal objects, circuit breaker boxes, air conditioners and heater ducts since they may cause interference and reduce the console’s sensitivity. Select a site that is not susceptible to drastic temperature changes. Mount the Magellan console as central as possible to the proposed placement of the wireless transmitters. Mount the Magellan console as high as possible. Avoid installing Magellan in the basement as the range of the console is reduced when installed below ground level. However, if it is absolutely necessary to install the console in the basement, install the console as high as possible. Install the Magellan console on a wall allowing at least 5cm (2”) around the console to permit adequate ventilation and heat dissipation. The Wall Plate Magellan uses a plastic wall plate to stay mounted on a wall. The wall plate is also used for tabletop mounting to cover the back of the console as well as keep any wires within their respective wire slots. After choosing an appropriate location (see Location on page 11), mount the wall plate onto the Magellan console with two screws as described in Mounting Magellan on the Wall on page 11 or Tabletop Mounting on page 12. Paradox Magellan Systems Figure 16: Magellan’s Back Plate Mounting Magellan on the Wall Magellan can be mounted on a wall by first securing the wall plate (see The Wall Plate on page 11) to the wall and then mounting the Magellan console on the secured wall plate as shown in Figure 15 on page 11 and Figure 16 on page 11. To do so: 1. Place the wall plate on the desired spot of the wall. 2. Drill and insert screws into holes labeled A as shown in Figure 14 on page 11. 3. Place the console back plate flush against the mounted wall plate. 11 4. Slide the Magellan’s open slots labeled D (see Figure 16 on page 11) onto the wall plate’s tabs labeled B (see Figure 15 on page 11). 5. Gently apply downward pressure to insert the wall plate’s tabs into Magellan’s open slots. 6. Insert two screws through the wall plate’s screw holes labeled C and into holes labeled E (see Figure 15 on page 11 and Figure 16 on page 11) in the Magellan back plate. This will secure the console to the wall. Figure 18: Connecting the Radio Antenna Tabletop Mounting Magellan can also be mounted on a tabletop. This is a useful convenience that allows Magellan to be situated on a nightstand, desk, kitchen counter, etc. Included with Magellan are two plastic feet as well as two rubber stops. The plastic feet raise the Magellan console to a slight angle for easy viewing while the rubber stops prevent the console from sliding when Magellan is being used. To do so: Radio Antenna Back view of the Magellan console. 1. Place the console back plate flush against the wall plate. 2. Slide the Magellan’s open slots labeled D (see Figure 16 on page 11) onto the wall plate’s tabs labeled B (see Figure 15 on page 11). 3. Gently apply downward pressure to insert the wall plate’s tabs into Magellan’s open slots. 4. Insert two screws through the wall plate’s screw holes labeled C and into holes labeled E (see Figure 16 on page 11) in the Magellan back plate. 5. Attach the plastic feet and rubber stops as shown in Figure 17 on page 12. Figure 17: Mounting Magellan on a Tabletop Plastic feet (x2) Wall plate Rubber stops (x2) Tabletop Tabletop mounting may not be an approved installation method by local regulations. It is recommended that the local regulations be verified prior to installing the Magellan console using this method. Connecting the Radio Antenna (MG-6160 only) If the radio’s reception is not very good, connect the supplied radio antenna to the ANT terminal on the back of the Magellan console as shown in Figure 18 on page 12. Move the antenna around until the spot with the best reception is found. 12 Reference & Installation Manual Programming Methods WinLoad Installer Upload/Download Software Program the Magellan console remotely or on-site using the WinLoad Installer Upload/Download Software for Windows®. For more information, contact your local Paradox Distributor or visit our Web site at paradox.com. If you are using the WinLoad software, you must program the features explained on page 38. Please refer to WinLoad’s Online Help for more information on using WinLoad. Feature Select Programming Method After entering certain sections, eight options will be displayed whereby each option from [1] to [8] represents a specific feature or option. To manipulate the options: • • • Press the key corresponding to the desired option and the option number will appear in the LCD display. This means the option is ON. Press the key again to remove the digit from the LCD display, thereby, turning OFF the option. Press the [*] key to set all eight options to OFF. Press the keys until the current section’s options are set. When the options are set, press the [#] key to save and advance to the next section. Press the [*] key twice to exit without changing any data. Programming Using the Built-in Keypad Use the built-in keypad to access Magellan’s programming mode. Use the supplied Magellan Programming Guide to keep track of which sections were programmed and how. To access programming mode: 1. 2. 3. 4. Press and hold the [0] key. Enter your [INSTALLER CODE] or [MAINTENANCE CODE]. Enter the 3-digit [SECTION] you wish to program. Enter the required [DATA]. There are two methods that can be used to enter data when in programming mode: Single Digit Data Entry and Feature Select Programming. Single Digit Data Entry Method After entering programming mode, some sections will require that you enter decimal values from 000 to 255. Other sections will require that you enter hexadecimal values from 0 to F. The required data will be clearly indicated in this manual as well as in the Magellan Programming Guide. When entering the final digit in a section, Magellan will automatically save and advance to the next section. Table 1 (see below) shows the keys and their equivalent decimal and/or hexadecimal value. Table 1: Decimal and Hexadecimal Values Key Value Key Value [1] [9] [2] [0] 0 (decimal) Space (Hexadecimal) [3] [1] CK* A (Hexadecimal only) [4] [2] CK* B (Hexadecimal only) [5] [3] CK* C (Hexadecimal only) [6] [4] CK* D (Hexadecimal only) [7] [5] CK* E (Hexadecimal only) [8] [6] CK* F (Hexadecimal only) * CK = Center keypad Paradox Magellan Systems Programming Using a Paradox Memory Key The Paradox Memory Keys (PMC-3) are very useful when multiple Magellan consoles are to be programmed identically. Rather then programming each console by entering its programming mode and then scrolling through programming sections, use a memory key to program each console. The programming of a console with a memory key takes approximately three seconds. There are two actions that can be performed with a memory key. Download Data to Destination Console To download the data of a memory key into a console: 1. Remove power from the Magellan console (AC and battery) and connect the memory key to the 5-pin connector on the left side of the back of the console (see Figure 13 on page 11). 2. Re-apply both AC and battery power to the console. 3. Press the [OK] key and Magellan will begin downloading the data from the memory key. Copy Data to Memory Key from Source Console To copy the contents of a console into the memory key. 1. Remove power from the Magellan console (AC and battery) and connect the memory key to the 5-pin connector on the left side of the back of the console (see Figure 13 on page 11). 2. Re-apply both AC and battery power to the console. 3. Press the [NEXT] key and then the [OK] key. Magellan will begin copying its data into the memory key. The Installer code of the Magellan console used to download data to the memory key must be the same Installer code programmed in the Magellan console that is to download the contents from the same memory key. If the Installer codes do not match, the contents of the memory key cannot be downloaded into the receiving console. Example: The contents of the Magellan console A will be copied into memory key B. The Installer code for console A is 111111. In order to download the contents of memory key B into the Magellan console C, the Installer code programmed in console C must also be 111111. 13 User Codes A person must be assigned to a User code in order to have access to Magellan. A User code defines the extent of a user’s access to the system and consists of a code # (PIN) and user options. Magellan supports one Installer code, one Maintenance code and up to 16 User codes (one System Master code and 15 User codes). Installer Code Used to program all console settings except User codes and remote controls. Maintenance Code Identical to the Installer code except that the code cannot program some communication settings. System Master Code User Code 001 Provides access to the following Magellan user features: language, voice and utility reporting, delays and tones, zone labels, system tests. Arm and disarm using any method as well as program User codes. 15 User Codes User Codes 002 to 016 Can arm and disarm the system. Maintenance Code Section [182]; Default = 111111 The Maintenance code is similar to the Installer code. It can be used to enter the console’s programming mode (see Programming Using the Built-in Keypad on page 13), which allows you to program all features, options and commands except for the console’s communication settings (sections [108] to [112] and [180] to [182]) as well as any User code. The Maintenance code can be 4 or 6 digits in length (see User Code Length on page 14). Each digit can be any value from 0 to 9. To change the Maintenance code: 1. Access the installer programming mode (see page 13). 2. Enter section [182]. 3. Enter a new [4- OR 6-DIGIT MAINTENANCE CODE]. OR 1. Press [MENU] + [4] + [INSTALLER CODE] + [8] + [NEW CODE]. User Code Length System Master Code Section [090]: Option [1] Option [1] OFF = 6-digit User codes Option [1] ON = 4-digit User codes (default) With the System Master code a user can use any arming method and can program any user’s (from 1 to 16) Access code. The System Master code can be 4 or 6 digits in length (see User Code Length on page 14), where each digit can be any digit from 0 to 9. The System Master code cannot be changed by the Installer or Maintenance code, but it can be reset to default. All User codes can be set to lengths of either 4 or 6 digits. When the 4-digit option is selected, entering a 4-digit code will allow access. Using the 6-digit option, entering 6 digits is required to allow access. If the User code length is changed from 4 digits to 6 digits when User codes have already been programmed, the console will automatically add the last 2 digits by using the first 2 digits. For example, if the Access code is 1234 and you switch to 6 digits, the code will become 123412. Be sure to verify the Access codes after switching from 4-digit to 6-digit Access codes. When switching from 6 digits to 4 digits, the console will simply remove the final 2 digits of the Access code. For example, 123456 will become 1234. Lock System Master Code Section [090]: Option [3] Option [3] OFF = System Master code unlocked (default) Option [3] ON = System Master code locked With section [090] option [3] enabled, the System Master code can only be changed or deleted through WinLoad or a power down reset. Reset System Master Code Installer Code Section [200] Section [181]; Default = 000000 Enter section [200] to reset the System Master code to default (1234/123456). The Installer code is used to enter the console's programming mode (see Programming Using the Built-in Keypad on page 13), which allows you to program all the features, options and commands of the Magellan console. The Installer code can be 4 or 6 digits in length (see User Code Length on page 14) where each digit can be any value from 0 to 9. The Installer code cannot be used to program any User code. To change the Installer code: 1. Access the installer programming mode (see page 13). 2. Enter section [181]. 3. Enter a new [4- OR 6-DIGIT INSTALLER CODE]. OR 1. Press [MENU] + [4] + [INSTALLER CODE] + [8] + [NEW CODE]. 14 Make sure that the Lock System Master Code feature (section [090] option [3]) is disabled. Duress Code Section [090]: Option [4] Option [4] OFF = Duress code disabled (default) Option [4] ON = User code 016 becomes a Duress code With this feature enabled, User code 016 becomes a Duress code. When forced to arm or disarm their system, users can enter a Duress code (User code 016) to arm or disarm the system which can immediately transmit a silent alert to the Monitoring Station, transmitting the Duress report code programmed in section [148] (see page 28). Reference & Installation Manual Zone Programming Magellan supports up to 32 wireless zones whereby each zone can be configured with a different zone definition and option. Each zone can also have a voice label recorded for it. Magellan’s zones can be programmed using section programming or through the Installer menu. See Quick Setup on page 4 for more information on zone programming using the Installer menu. Zone Definitions Sections [001] to [032] represent zones 1 through 32 respectively, whereby the first three digits in each of these sections represents the zone's definition. To disable a zone, enter 000 and then press the [#] key. There are 15 available Zone Definitions, which are described as follows: Entry Delay 1 Zone Programming Overview Sections [001] to [032]: Zones 1 to 32, 3-digit # = 001 After assigning and setting up your wireless transmitters, define the associated zone's parameters. The zone parameters define the type of zone and how the control panel will react when an alarm condition occurs on that zone. These zone parameters are programmed into one section as detailed in Figure 19 on page 15. When the system is armed and a zone defined with Entry Delay 1 opens, the console will generate an alarm after the programmed Entry Delay 1 Timer elapses. This is to provide users with enough time to enter the protected area and disarm the system. Entry Delay zones are commonly used at the entry/ exit points of the protected area (i.e., front/back door, garage, etc.). Using different Entry Delays (see Entry Delay 2 below) is useful when, for example, one entry point requires a longer delay than another entry point. Figure 19: Magellan Zone Programming Overview [001] = Zone 1 [002] = Zone 2 [003] = Zone 3 [004] = Zone 4 [005] = Zone 5 [006] = Zone 6 [007] = Zone 7 [008] = Zone 8 [009] = Zone 9 [010] = Zone 10 [011] = Zone 11 [012] = Zone 12 [013] = Zone 13 [014] = Zone 14 [015] = Zone 15 [016] = Zone 16 [017] = Zone 17 [018] = Zone 18 [019] = Zone 19 [020] = Zone 20 [021] = Zone 21 [022] = Zone 22 [023] = Zone 23 [024] = Zone 24 [025] = Zone 25 [026] = Zone 26 [027] = Zone 27 [028] = Zone 28 [029] = Zone 29 [030] = Zone 30 [031] = Zone 31 [032] = Zone 32 Zone Definition 000 = Zone disabled 001 = Entry Delay 1 002 = Entry Delay 2 003 = Follow 004 = Follow / Stay 005 = Instant 006 = Instant / Stay 007 = Instant Fire 008 = Delayed Fire Zone 009 = 24Hr. Burglary 010 = 24Hr. Hold-up 011 = 24Hr. Buzzer 012 = 24Hr. Gas 013 = 24Hr. Heat 014 = 24Hr. Water 015 = 24Hr. Freeze Zone Options* [1] = Auto-zone Shutdown (default) [2] = Zone Bypass (default) [3] = Future use [4] Press and hold the [0] key Enter the desired 3-digit delay value from 000 to 255 seconds into section [060] to program the Entry Delay 1 Timer. Enter your [INSTALLER CODE] or [MAINTENANCE CODE] Entry Delay 2 Sections [001] to [032]: Zones 1 to 32, 3-digit # = 002 Enter 3-digit [SECTION] Entry Delay 2 zones are identical to the Entry Delay 1 zones (see Entry Delay 1 on page 15), except it uses a separate Entry Delay Timer. Entry Delay 2 Timer Section [061]: 001 to 255 seconds; 000 = Disabled; Default = 45 seconds Enter the desired 3-digit delay value from 000 to 255 seconds into section [061] to program the Entry Delay 2 Timer. Enter 3-digit [ZONE DEFINITION] Keypad beeps twice Follow Zones Sections [001] to [032]: Zones 1 to 32, 3-digit # = 003 Use feature select method (p. 13) to select the [ZONE OPTIONS] When an armed Follow zone opens, the console will immediately generate an alarm unless an Entry Delay zone opens first as described in the situations below: • [5] Zone Alarm Type • OFF OFF Audible alarm (steady) OFF ON Audible alarm (pulsed) ON OFF Silent alarm ON Entry Delay 1 Timer Section [060]: 001 to 255 seconds; 000 = Disabled; Default = 45 seconds ON Generate report only [6] = Intellizone [7] = Delay alarm transmission [8] = Force Zone * Available through Section Programming only. Paradox Magellan Systems Press the [#] key to save If an armed Follow zone opens after an Entry Delay zone opens, the console waits until the Entry Delay Timer has elapsed before generating an alarm. If an armed Follow zone opens after more than one Entry Delay zone opens, the console will wait until the Entry Delay Timer of the zone that opened first has elapsed. This feature is commonly used when a motion detector is protecting the area occupied by the entry point keypad. This will prevent the motion detector from causing an alarm when a user enters through the entry point to disarm the system. 15 Follow/Stay Zones Figure 21: Delayed Fire Zone Sections [001] to [032]: Zones 1 to 32, 3-digit # = 004 Follow/Stay zones function as follows: • • All zones defined as Follow/Stay zones become Follow zones (refer to Follow Zones on page 15) when the Magellan system is Regular armed. All zones defined as Follow/Stay zones become Stay zones when the Magellan system is Stay or Instant armed. Instant Zones Sections [001] to [032]: Zones 1 to 32, 3-digit # = 005 When an armed Instant zone opens, the console immediately generates an alarm. Instant zones are commonly used for windows, patio doors, skylights and other perimeter type zones. Instant/Stay Zones Sections [001] to [032]: Zones 1 to 32, 3-digit # = 006 Instant/Stay zones function as follows: • • All zones defined as Instant/Stay zones become Instant zones (refer to Instant Zones on page 16) when the Magellan system is Regular armed. All zones defined as Instant/Stay zones become Stay zones when the Magellan system is Stay or Instant armed. Standard 24Hr. Fire Zones Sections [001] to [032]: Zones 1 to 32, 3-digit # = 007 Whenever a Standard 24Hr. Fire zone opens, whether it is armed or disarmed, the console will generate the following: 24Hr. Burglary Zones • Whenever a 24Hr. Burglary zone opens, whether the system is armed or disarmed, the console will immediately generate an alarm. • The console can send the corresponding Alarm Report Code from sections [131] to [138]. Alarms are always audible regardless of other settings. Fire alarms generate an intermittent (pulsed) bell/siren output signal as shown in Figure 20 on page 16. Sections [001] to [032]: Zones 1 to 32, 3-digit # = 009 24Hr. Hold-up Zones Figure 20: Bell/Siren Output during a Fire Alarm Sections [001] to [032]: Zones 1 to 32, 3-digit # = 010 When a 24Hr. Hold-up zone opens, whether it is armed or disarmed, the console will immediately generate an alarm. The SIA FSK reporting format includes specific report codes to identify the alarm as a Hold-up alarm (see Appendix 1: Automatic Report Code List on page 39). 24Hr. Buzzer Zones Sections [001] to [032]: Zones 1 to 32, 3-digit # = 011 Delayed Fire Zones Sections [001] to [032]: Zones 1 to 32, 3-digit # = 008 When a Delayed 24Hr. Fire zone opens, whether it is armed or disarmed, the console will react as shown in Figure 21 on page 16. Delayed 24Hr. Fire zones are commonly used in residential homes where a smoke detector often generates false alarms (i.e., burning bread, etc.). This feature is not for use in UL installations. This zone definition is particularly useful when a user wishes to be notified when something such as a safe or locker within the home has been accessed (i.e., a child accessing a valuable collection). This zone definition functions as follows: • • • 16 Whenever a 24Hr. Buzzer zone opens, whether the console is armed or disarmed, the console sets off the keypad’s buzzer to indicate that the zone was breached. The console will report the alarm, but will not enable the bell/ siren output. Enter any valid Access code on the keypad to stop the buzzer. Reference & Installation Manual 24Hr. Gas Zones Bypass Option Sections [001] to [032]: Zones 1 to 32, 3-digit # = 012 Section [001] to [032]: Zones 1 to 32; Option [2] When a 24Hr. Gas zone opens, whether it is armed or disarmed, the console will immediately generate an alarm. The SIA FSK reporting format includes specific report codes to identify the alarm as a Gas alarm (see Appendix 1: Automatic Report Code List on page 39). Option [2] OFF = Bypass option disabled Option [2] ON = Selected zone is Bypass enabled (default) 24Hr. Heat Zones When a user uses the Bypass Programming feature, only zones with the Bypass option enabled can be programmed as bypassed. Fire zones cannot be programmed with the Bypass option because the console will not bypass a Fire zone. Sections [001] to [032]: Zones 1 to 32, 3-digit # = 013 When a 24Hr. Heat zone opens, whether it is armed or disarmed, the console will immediately generate an alarm. The SIA FSK reporting format includes specific report codes to identify the alarm as a Heat alarm (see Appendix 1: Automatic Report Code List on page 39). Alarm Types Sections [001] to [032]: Zones 1 to 32; Options [4] and [5] When an alarm condition occurs, the console can be programmed to react as shown in Table 2 on page 17. Table 2: Alarm Type Options 24Hr. Water Zones Options Description Sections [001] to [032]: Zones 1 to 32, 3-digit # = 014 When a 24Hr. Water zone opens, whether it is armed or disarmed, the console will immediately generate an alarm. The SIA FSK reporting format includes specific report codes to identify the alarm as a Water alarm (see Appendix 1: Automatic Report Code List on page 39). 24Hr. Freeze Zones [4] [5] OFF OFF Audible steady alarm (default) When the conditions for an alarm have been met, the control panel can transmit the appropriate Zone Alarm report code (see page 27) and provides a steady output for the on-board siren. OFF ON Audible pulsed alarm When the conditions for an alarm have been met, Magellan can transmit the appropriate Zone Alarm report code (see page 27) and provides a pulsed output (see Figure 20 on page 16) for the on-board siren. ON OFF Silent alarm When the conditions for an alarm are met, the control panel can transmit the appropriate Zone Alarm report code (see page 27) and will not activate the control panel’s bell output. The appropriate ARM or STATUS LED on the keypads will flash to indicate an alarm and the user will still have to disarm the system. ON ON Report only When the conditions for an alarm have been met, the control panel can transmit the appropriate Zone Alarm report code (see page 27). The system will not have to be disarmed. Sections [001] to [032]: Zones 1 to 32, 3-digit # = 015 When a 24Hr. Freeze zone opens, whether it is armed or disarmed, the console will immediately generate an alarm. The SIA FSK reporting format includes specific report codes to identify the alarm as a Freeze alarm (see Appendix 1: Automatic Report Code List on page 39). Zone Options Sections [001] to [032] represent zones 1 through 32 respectively as demonstrated in Figure 19 on page 15. After entering the 3-digit Zone Definition (see Zone Definitions on page 15), select one or more of the following Zone Options by using the Feature Select Programming Method (see page 13). Auto-zone Shutdown Sections [001] to [032]: Zones 1 to 32; Option [1] Option [1] OFF = Auto-zone Shutdown disabled Option [1] ON = Auto-zone Shutdown enabled (default) If, in a single armed period, the number of alarms generated by a zone with the Auto-zone Shutdown option enabled exceeds the number defined by the Auto-zone Shutdown Counter, the console will no longer generate an alarm for that zone. The Autozone Shutdown Counter resets every time the system is armed. Auto-zone Shutdown Counter Section [067]: 001 to 015 alarms; 000 = Disabled; Default = 5 alarms Enter the desired limit into section [067] to program the Auto-zone Shutdown Counter. Paradox Magellan Systems The Alarm Type options cannot be programmed for Fire zones. Fire zones are automatically programmed with an audible pulsed alarm. This cannot be altered. Intellizone Sections [001] to [032]: Zones 1 to 32; option [6] Option [6] OFF = Intellizone disabled (default) Option [6] ON = Intellizone enabled This feature reduces the possibility of false alarms. When a zone with the Intellizone option opens, the console does not immediately generate an alarm. First it triggers the Intellizone Delay Timer. If any of the following conditions occur during this period, the panel will generate an alarm: 17 • • • During the Intellizone Delay, a second zone has caused an alarm. During the Intellizone Delay, the zone in alarm has restored (closed) and re-occurred (opened). The zone in alarm is still open after the Intellizone Delay has elapsed. This feature is not for use in UL installations. Stay Delay Zones Section [094]: Options [1] Option [1] OFF = Stay Delay zone disabled (default) Option [1] ON = Stay Delay zone enabled When a Follow/Stay or Instant/Stay zone is armed using the Stay or Instant arming methods, with this option enabled and the zone is triggered, an alarm will not generate until the programmed Stay Delay elapses. A zone defined as Stay Delay follows the Entry Delay 1 Timer. To program the Entry Delay Timers, refer to Entry Delay 1 on page 15. Intellizone Delay Timer Section [065]: 010 to 255 seconds; Default = 45 seconds This feature is not for use in UL installations. Enter the desired 3-digit value into section [065] to program the Intellizone Delay Timer. Delay Before Alarm Report Code Transmission Zones 31 and 32 Become Hardwire Zones Option [7] OFF = Delay alarm transmission disabled (default) Option [7] ON = Delay alarm transmission enabled Section [095]: Options [1] and [2] Option [1] OFF = Wireless zone 31 remains unchanged (default) Option [1] ON = Wireless zone 31 uses the on-board hardwire zone input 1 This feature is commonly used with Entry Delay zones to reduce false alarms created by new users who may not disarm the system in time. This feature works as follows: Option [2] OFF = Wireless zone 32 remains unchanged (default) Option [2] ON = Wireless zone 32 uses the on-board hardwire zone input 2 • The Magellan console comes with two on-board zone inputs, hardwire zone inputs 1 and 2. Section [095] options [1] and [2] allow you to convert zones 31 and 32 from wireless to hardwire by allowing you to connect hardwire detection devices (i.e., door contacts) to zone inputs 1 and 2. Sections [001] to [032]: Zones 1 to 32; option [7] • When an alarm condition occurs on a zone with this option enabled, the console enables the bell/siren output, but does not report the alarm to the monitoring station until the end of the Alarm Transmission Delay. During this period, disarming the system disables the bell/ siren output and cancels the report code transmission. This feature is not for use in UL installations. Alarm Transmission Delay Section [075]: 001 to 255 seconds; 000 = Disabled; Default = 0 seconds Enter the desired 3-digit delay value into section [075] to program the Alarm Transmission Delay. Force Zones Sections [001] to [032]: Zones 1 to 32; Option [8] Option [8] OFF = Force zone disabled Option [8] ON = Selected zone is Force enabled (default) Any open Force zones at the time of arming will be considered deactivated by the console. If during this period a deactivated zone is closed, the console will revert that zone to active status. Consequently, the console will generate an alarm if the zone is breached. Fire zones cannot be programmed with the Force zone option because the console will not bypass a Fire zone when the system is being Force armed. This feature is not for use in UL installations. • • With section [095] option [1] ON, zone 31 is connected to zone input 1. With section [095] option [2] ON, zone 32 is connected to zone input 2. EOL (End-Of-Line) Zones Section [095]: Option [3] Option [3] OFF = Hardwire zones 1 & 2 do not require EOL resistors (default) Option [3] ON = Hardwire zones 1 & 2 require EOL resistors This feature only applies to Magellan’s on-board zone inputs. Section [095] options [1] and/or [2] (see Zones 31 and 32 Become Hardwire Zones on page 18) must be ON in order to use this feature. If the hardwire detection devices connected to Magellan’s zone inputs 1 and 2 have input terminals that require 1K9 end-of-line resistors, enable (ON) section [095] option [3]. For details on using EOL resistors, refer to page 9. When hardwired zones are used, the EOL Resistor Option must be enabled for UL installations.Wireless Programming The Magellan system supports up to 32 wireless zones and two wireless doorbells. These wireless zones are monitored using transmitters such as wireless detectors and door contacts. The Magellan console only supports the Paradox Magellan series of wireless transmitters. The programming of the transmitters is accomplished in two steps: 1. Assign the wireless transmitter to Magellan. 2. Program the wireless zone. 18 Reference & Installation Manual Table 3: Wireless Doorbell Tones Assigning Wireless Zone Transmitters Section [096] - Options [1] and [2] Sections [201] to [232]: Zones 1-32; Wireless Transmitters 1-32 Sections [201] to [232] represent zones 1 to 32. A wireless transmitter assigned to a section ([201] to [232]) will be assigned to the zone represented by the section. For example, a wireless transmitter assigned to section [205] will be assigned to zone 5. Doorbell Tone # Option [1] OFF / Option [2] OFF (Doorbell 1) Tone 1 (default) Option [1] OFF / Option [2] ON (Doorbell 1) Tone 2 Option [1] ON / Option [2] OFF (Doorbell 1) Tone 3 Option [1] ON / Option [2] ON (Doorbell 1) Tone 4 To assign a wireless transmitter: Section [096] - Options [3] and [4] 1. Access the installer programming mode (see page 13). 2. Enter the [SECTION] corresponding to the desired zone. 3. Enter the 6-digit [SERIAL NUMBER] of the wireless transmitter. The serial number is located on the inside of the wireless transmitter. The wireless transmitters must be activated once having been assigned to the Magellan console. To activate a transmitter, insert the batteries and close the cover. To ensure proper synchronization between the console and the transmitter, open and close the zone corresponding to the transmitter. Are the zones that have wireless transmitters assigned to them programmed? See Zone Definitions on page 15 and Zone Options on page 17. Wireless transmitters can also be assigned through the Installer menu. Press [MENU] + [4] + [INSTALLER CODE] + [6]. Select the zone you wish to assign the transmitter to, press [OK], open the cover of the transmitter and then close the cover. The transmitter has been assigned. Refer to the Magellan Quick Setup on page 4 for more information on the Installer menu and the assignment of the wireless transmitters. Doorbell Tone # Option [3] OFF / Option [4] OFF (Doorbell 2) Tone 1 Option [3] OFF / Option [4] ON (Doorbell 2) Tone 2 (default) Option [3] ON / Option [4] OFF (Doorbell 2) Tone 3 Option [3] ON / Option [4] ON (Doorbell 2) Tone 4 Deleting Assigned Wireless Transmitters Sections [201] to [232]: Zones 1-32; Wireless Transmitters 1-32 Sections [233] and [234]: Wireless Doorbells 1 and 2 To delete an assigned wireless transmitter: 1. Access the installer programming mode (see page 13). 2. Enter the [SECTION] corresponding to the desired zone or doorbell. 3. Press the [0] key six times to clear the wireless transmitter’s serial number. Assigning Wireless Doorbells to the Console Viewing Wireless Transmitter Signal Strength Sections [233] and [234]: Wireless Doorbells 1 and 2 Sections [201] to [232]: Zones 1-32; Wireless Transmitters 1-32 Magellan supports the use of two wireless doorbells. By connecting a pushbutton to the Universal Transmitter inputs of a Magellan Wireless Door Contact (MG-DCT1 or MG-DCTXP2), the MG-DCT1/MG-DCTXP2 will transmit a signal to Magellan whenever the pushbutton is pressed. Magellan will in turn become a doorbell and play a predetermined tone (see Wireless Doorbell Tones on page 19). Once wireless transmitters have been assigned to the Magellan console, the signal strength of each transmitter can be verified in sections [201] to [232] (zones 1 to 32 respectively). Each section represents the signal strength viewer for the wireless transmitter assigned to the corresponding zone. Please refer to the appropriate Magellan Wireless Door Contact Instruction for information on the installation and configuration of the wireless door contact. For example, section [201] is the viewer for the wireless transmitter assigned to zone 1 and section [232] is the viewer for the wireless transmitter assigned to zone 32. To assign a wireless doorbell: The signal strength is displayed using two terms: 1. Access the installer programming mode (see page 13). 2. Enter the [SECTION] corresponding to the desired doorbell. 3. Enter the 6-digit [SERIAL NUMBER] of the MG-DCT1. • • Wireless Doorbell Tones Section [096]: Options [1] to [4] Options [1] and [2] = Set tone for wireless doorbell 1 Options [3] and [4] = Set tone for wireless doorbell 2 Section [096] options [1] to [4] set the tones that will be played when Magellan receives a signal from either wireless doorbell 1 or 2 or both. Magellan comes with four tones. Refer to Table 3 on page 19 to set the desired tone. Paradox Magellan Systems “Good”: This is an average reading and is acceptable. “Weak”: This is the weakest reading. The transmitter should be moved to another location. Sometimes moving the transmitter by a small amount will greatly increase the signal reception. To view the signal strength of a wireless transmitter: 1. Access the installer programming mode (see page 13). 2. Enter the [SECTION] corresponding to the desired zone or doorbell. 3. The LCD will display either “Good” or “Weak” on the screen. When performing a signal strength test, Magellan also displays the noise level surrounding each of the transmitters. “Low” refers to a low level of noise while “High” refers to a noisy environment. 19 The signal strength can also be verified by performing a system test. See Quick Setup on page 4 for more information. Although remote controls can be assigned by the System Master, the remote control’s buttons are programmed by the installer. Assigning Remote Controls The Magellan console accepts up to 16 fully programmable remote controls. Every User code can have one remote control assigned to it. To assign a remote control: Each remote control can be programmed to perform different actions. Each digit in sections [041] to [056] represents a button or combination of buttons (see table below). To program a remote control’s buttons: 1. 2. Press [MENU] + [4] + [2]. 1. The remote control will transmit a signal for only 1 second when a button is pressed and held for 1 second. This is done to conserve the remote control’s batteries. 3. Programming the Remote Control’s Buttons Sections [041] to [056]: Users 1 to 16; Remote Controls 1 to 16 Access the installer programming mode (see page 13). Enter the [SECTION] (sections [041] to [056]) corresponding to the desired remote control. Enter the [HEXADECIMAL VALUE] (0 to F) of the desired button option from the Button Options Table on page 23. If you do not wish to program all the buttons or button combinations, press the [#] key at any time to save and exit. Sections [041] to [056] represent the remote controls assigned to User codes 1 to 16 (see table below). If you enable any Panic button options, you must enable the Panic options in the control panel (refer to Panic Alarms on page 26). Programming the MG-REM1/MG-REM2 Warning: When section [040] is accessed, the console will copy the saved value of that section to all remotes. Section RC# Data (Default: 4DE0) Section RC# Data (Default: 4DE0) [040] Default 1-16 ______ ______ ______ ______ [041] ______ ______ ______ ______ [049] ______ ______ ______ ______ [042] ______ ______ ______ ______ [050] 10 ______ ______ ______ ______ [043] ______ ______ ______ ______ [051] 11 ______ ______ ______ ______ [044] ______ ______ ______ ______ [052] 12 ______ ______ ______ ______ [045] ______ ______ ______ ______ [053] 13 ______ ______ ______ ______ [046] ______ ______ ______ ______ [054] 14 ______ ______ ______ ______ [047] ______ ______ ______ ______ [055] 15 ______ ______ ______ ______ [048] ______ ______ ______ ______ [056] 16 ______ ______ ______ ______ 20 Reference & Installation Manual Button Options Table MG-REM1 MG-REM2 0 - Button disabled 1 - Regular arming 2 - Stay arming 3 - Instant arming 4 - Force arming 5 - N/A 6 - N/A 7 - N/A 8 - Panic 1† 9 - Panic 2† A* - Panic 3† B* - PGM Activation (Event Group #7, see Appendix 1: PGM Event Table) C* - PGM Activation (Event Group #8, see Appendix 1: PGM Event Table) D* - Turn FM radio ON/OFF (MG-6160 only) E* - FM radio memory scan (MG-6160 only) F* - Non-medical alarm * = Hex values A to F are keys [1] to [6] from Magellan’s Center Keypad. Refer to Figure 1 on page 2. † = The panic feature (section [091] options [1] to [3]) must be enabled. The button of the MG-REM1 and MG-REM2 remote controls has been permanently programmed to disarm the system. However, when the system is disarmed and the Magellan console’s radio is on (MG-6160 only), the The button’s functionality cannot be altered. The button can be used for volume control. button of the MG-REM2 remote control has been permanently programmed to request feedback from the system. The button’s functionality cannot be altered. The combinations do not function with the MG-REM1 remote control. The with the MG-REM2 remote control. and button combinations do not function and button When section [040] is accessed, the console will display the contents of section [041] and copy the saved value of that section to all remote options: [041] to [56]. Assigning Wireless Keypads Wireless Repeater Options Sections [243] to [246]: Keypads 1-4 Section [300] to [305]:Options [1] to [8]; Repeater 1 options Section [306] to [311]:Options [1] to [8]; Repeater 2 options Defaults = OFF Sections [243] to [246] represent keypads 1 to 4. To assign a wireless keypad: 1. Access the installer programming mode (see page 13). 2. Enter the [SECTION] corresponding to the desired keypad. 3. Enter the 6-digit [SERIAL NUMBER] of the wireless keypad. Assigning Wireless Repeaters Sections [247] to [248]: Repeater 1-2 Sections [247] to [248] represent repeater 1 and 2. To assign a wireless repeater: Sections [300] to [303] represent zone repeating options for Repeater 1. Section [304] represents PGM repeating options for Repeater 1. Section [305] represents wireless keypad and doorbell repeating options. Sections [306] to [309] represent zone repeating options for Repeater 1. Section [310] represents PGM repeating options for Repeater 1. Section [311] represents wireless keypad and doorbell repeating options. By default, each option is OFF. Enable the option to have the respective zone/PGM/wireless keypad/doorbell repeated. 1. Access the installer programming mode (see page 13). 2. Enter the [SECTION] corresponding to the desired repeater. 3. Enter the 6-digit [SERIAL NUMBER] of the wireless repeater. Paradox Magellan Systems 21 Arming and Disarming Regular Arming Switches to Stay Arming Section [092]: Option [4] Option [4] OFF = Regular arming switches to Stay arming disabled (default) Option [4] ON = Regular arming switches to Stay arming enabled If a user Regular arms the system, but does not exit through (open and close) an Entry Delay zone during the Exit Delay, the console can be programmed to switch from Regular arming to Stay arming. • • The console will enter a 60-second Exit Delay period before arming the system. At this point, Auto-arming can be cancelled by entering a valid Access code. Once the system has successfully armed, the console can transmit the Timed Auto-Arming report code programmed in section [124]. Example: To automatically arm the system everyday at 6:15PM, enable section [092] option [1] to activate Timed Auto-arming and then key in 18:15 into section [085]. This feature is not for use in UL installations. Regular Arming Switches to Force Arming Auto-arm Timer Section [092]: Option [5] Option [5] OFF = Regular arming switches to Force arming disabled Option [5] ON = Regular arming switches to Force arming enabled (default) Section [085] With this feature enabled, the console will always Force arm instead of Regular arm when a valid User code is entered. In installations where the user must always Force arm when leaving the protected area, this feature allows users to Force arm after entering their User code. This feature is not for use in UL installations. Stay Arming Switches to Force Arming Using the 24-hour clock (i.e., 6:30PM = 18:30), program the time that you wish the console to attempt to arm the system and/or send the Late to Close report code. No Movement Auto-Arming Section [092]: Option [2] Option [2] OFF = No Movement Auto-arming disabled (default) Option [2] ON = No Movement Auto-arming enabled If no movement occurs in a zone's protected area for the period specified by the No Movement Timer (see below), the console can automatically arm the system. • Section [092]: Option [6] Option [6] OFF = Stay Arming Switches to Force Arming disabled (default) Option [6] ON = Stay Arming Switches to Force Arming enabled • With this feature enabled, the console will always Force arm and Stay arm when a valid User code is entered even if there are perimeter zones open. • This feature is not for use in UL installations. Timed Auto-Arming Section [092]: Option [1] Option [1] OFF = Timed Auto-arming disabled (default) Option [1] ON = Timed Auto-arming enabled The Magellan system can be programmed to arm every day at the time specified by the Auto-arm Timer (see Auto-arm Timer on page 22). The following also apply: • • The Auto-arming options (see Auto-Arming Options on page 23) determine the arming method. Any open zones detected when the system is Auto-armed will be bypassed regardless of their definition (except 24Hr. zones). movement has been detected for the period specified by the No 22 • • The Auto-arming option (see Auto-Arming Options on page 23) determines the system's arming method. Any open zones detected when the system is Auto-armed will be bypassed regardless of their definition (except 24Hr. zones). Upon arming, the console will transmit the No Movement report code if programmed in section [124]. Regardless of whether the system was successfully armed or not, the console will always transmit the No Movement report code if programmed in section [124]. If No Movement Auto-arming is disabled, the console will still send the No Movement report code at the time specified by the No Movement Timer. Example: To arm the system whenever there is no movement for a period of 4 hours, enable section [092] option [2] (No Movement Auto-arming) and then in section [064], enter 016 (16 x 15min. = 240min. = 4 hours). This feature is not for use in UL installations. No Movement Timer Section [064]: 001 to 255 x 15 minutes; 000 = Disabled; Default = 000 Program the interval of time without movement that you wish the console to wait before arming and/or sending the No Movement report code. If No Movement Auto-arming is disabled, the console can still send the No Movement report code when no Movement Timer. Reference & Installation Manual Auto-Arming Options Exit Delay Termination Section [092]: Option [3] Option [3] OFF = Auto-arm system using Regular arm (default) Option [3] ON = Auto-arm system using Stay arm Section [093]: Option [6] Option [6] OFF = Exit Delay Termination disabled Option [6] ON = Exit Delay Termination enabled (default) When using Timed Auto-arming (see page 22) or No Movement Auto-Arming (see page 22), the console can Regular or Stay arm the system. When option [6] is enabled (ON), the console will reduce the Exit Delay to 10 seconds when an Entry Delay zone (see Exit Delay on page 23) is opened and closed during the Exit Delay. This feature is not for use in UL installations. Example: 15 seconds into a 45 second Exit Delay, an Entry Delay zone opens and closes. The remaining 30 seconds is reduced to 10 seconds. One-Touch Arming Section [092]: Options [7] and [8] Option [7] OFF = One-touch Regular/Force arming disabled Option [7] ON = One-touch Regular/Force arming enabled (default) Option [8] OFF = One-touch Stay arming disabled Option [8] ON = One-touch Stay arming enabled (default) The One-touch arming features allow users to arm the system without having to enter any Access codes. To arm the system, press and hold the appropriate key for approximately 2 seconds. Exit Delay Section [062]: 001 to 255 seconds; 000 = disabled; Default = 60 seconds The Exit Delay determines the amount of time a user has to leave the protected area before Magellan arms the system. The Exit Delay applies to all zones (except 24Hr zones) in the system. Program the Exit Delay from 001 to 255 seconds. Bell Squawk on Arm/Disarm with Remote Control Section [093]: Option [3] Option [3] OFF = Bell squawk disabled (default) Option [3] ON = Bell squawk enabled When option [3] is enabled (ON), the siren will squawk once upon arming with a remote control and twice upon disarming with a remote control. This feature must be enabled in UL installations. No Exit Delay when Arming with Remote Control Section [093]: Option [4] Option [4] OFF = Provides Exit Delay when arming with remote control (default) Option [4] ON = No Exit Delay when arming with remote control Follow Zone Switches to Entry Delay 2 Section [093]: Option [7] Option [7] OFF = Follow zone triggers an alarm (default) Option [7] ON = Follow zone follows Entry Delay 2 when opened When option [7] is enabled (ON) and an Entry Delay 1 zone is bypassed, an armed Follow zone that opens without an Entry Delay being triggered will switch to the Entry Delay 2 timer. Example: Zone 1 is an Entry Delay zone and zone 2 is a Follow zone protecting the area where the keypad is installed. The system is armed but zone 1 is bypassed. With option [7] enabled, zone 2 will switch to and wait for the Entry Delay 2 timer to elapse before triggering an alarm. Closing Delinquency Timer Section [080]: 001 to 255 days; 000 = Disabled; Default = 000 The Magellan console will verify when the system was last armed at midnight of every day. If the last time the system was armed is greater than the programmed Closing Delinquency timer, the console will transmit a Closing Delinquency report code (see page 28) to the monitoring station. Enter a value from 001 to 255 days into section [080] to program the Closing Delinquency timer. Enter 000 to disable the timer. Stay Arm Siren Delay Section [095]: Option [4] Option [4] OFF = Stay Arm Siren Delay disabled Option [4] ON = Stay Arm Siren Delay enabled (default) When option [4] is enabled and an alarm is triggered on a stay armed system, the console plays an audible 15-second countdown that will increase in volume as the countdown progresses. While the system reports the alarm to the monitoring station immediately upon being triggered, the siren will not activate until the 15-second siren delay is complete. When option [4] is enabled (ON), the console cancels the Exit Delay (arms instantly) when the system is armed with a remote control. When disabled, the Exit Delay Timer will start when the system is armed with a remote control. Paradox Magellan Systems 23 Alarm Options Bell Cut-off Timer Section [063]: 001 to 255 minutes; 000 = Disabled; Default = 4 minutes After an audible alarm, the siren will stop upon the disarming of the system or when the Bell Cut-Off timer has elapsed, whichever comes first. • When option [8] is ON, the Wireless Transmitter Supervision Options (see page 24) will ignore the bypass definition. This means the console will generate an incident as per the set Wireless Transmitter Supervision Option if a Supervision Loss occurs on a bypassed zone. Check-in Supervision Options Wireless Transmitter Supervision Options Section [094]: Options [6] and [7] This feature determines how the Magellan console will react to a Supervision Loss trouble. Table 4 shows the different Supervision Loss combinations available and how the system will react when armed or disarmed. In UL installations, if a zone is used as a fire zone, the zone must be supervised and the check-in supervision time must be set to 80 minutes. Table 4: Wireless Transmitter Supervision Options Options Description [6] [7] OFF OFF Wireless transmitter supervision disabled OFF ON Trouble only (default) System armed or disarmed: If a Supervision Loss occurs on a zone, the console will display a trouble on the LCD screen and send a report to the monitoring station (if programmed). ON OFF Audible alarm when armed System armed: If a Supervision Loss occurs on a zone, the console will follow the zone's Alarm Types setting (see page 17). System disarmed: If a Supervision Loss occurs on a zone, the console will display a trouble on the LCD screen and send a report to the monitoring station (if programmed). ON ON Audible alarm System armed: If a Supervision Loss occurs on a zone, the console will follow the zone's Alarm Types setting (see page 17). System disarmed: It functions the same as Trouble Only setting, except it will also generate an audible alarm. Supervision Bypass Options Section [094]: Option [8] Option [8] OFF = No Supervision Loss if detected on a bypassed zone (default) Option [8] ON = Generate Supervision Loss if detected on a bypassed zone • When option [8] is OFF, the Wireless Transmitter Supervision Options (see page 24) will follow the zone's bypass definition. This means the console will not perform any action if a Supervision Loss occurs on a bypassed zone. 24 Section [290]: Section [291]: Section [292]: Section [293]: Options [1] to [8]; Zones 1 to 8; Default: All ON Options [1] to [8]; Zones 9 to 16; Default: All ON Options [1] to [8]; Zones 17 to 24; Default: All ON Options [1] to [8]; Zones 25 to 32; Default: All ON If enabled, Magellan can wait for each of its assigned wireless transmitters to send a status signal within a specified time (see Check-in Supervision Time on page 24) to confirm their presence and functionality. If a device has not sent a signal within the specified time period, Magellan can generate a trouble, an alarm and/or transmit a report code to the monitoring station as defined by the Wireless Transmitter Supervision Options (see page 24). Sections [190] and [193] determine which zones will be supervised and which will not. Enable the option pertaining to the zone you wish Magellan to supervise. This feature must be enabled in UL installations. Check-in Supervision Time Section [096]: Option [7] Option [7] OFF = Check-in Supervision Time = 24Hrs (default) Option [7] ON = Check-in Supervision Time = 80 minutes Section [096] option [7] defines the time period that Magellan will expect a check-in status signal from the specified wireless transmitters as defined in the Check-in Supervision Options (see page 24). If no signal is received within the check-in supervision time, Magellan’s reaction will be defined by the Wireless Transmitter Supervision Options (see page 24). In UL installations, if a zone is used as a fire zone, the zone must be supervised and the check-in supervision time must be set to 80 minutes. Tamper Recognition Options Section [094]: Options [3] and [4] This feature determines how the Magellan console will react to a zone tamper. Table 5 on page 25 shows the different Tamper Recognition combinations available and how the system will react when armed or disarmed. Reference & Installation Manual Table 5: Tamper Recognition Options Options Description [3] [4] OFF OFF Tamper Recognition disabled (default) OFF ON Trouble only System armed or disarmed: If a tamper wiring failure occurs on a zone, the console will generate a trouble and send a report to the monitoring station (if programmed). ON OFF Audible alarm when armed System armed: If a tamper failure occurs on a zone, the console will follow the zone's Alarm Types setting (see page 17). System disarmed: If a tamper failure occurs on a zone, the console will generate a trouble and send a report to the monitoring station (if programmed). ON ON Audible alarm System armed: If a tamper failure occurs on a zone, the console will follow the zone's Alarm Types setting (see page 17). System disarmed: It functions the same as Trouble Only setting, except it will also generate an audible alarm. Tamper Bypass Options Section [094]: Option [5] Option [5] OFF = Ignore any tampers detected on a bypassed zone (default) Option [5] ON = Generate tamper if detected on a bypassed zone • When option [5] is ON, the Tamper Recognition feature (see page 24) will ignore the zone’s bypass definition. This means the console will generate an incident as per the set Tamper Recognition option if a tamper occurs on a bypassed zone. • When option [5] is OFF, the Tamper Recognition feature (see page 24) will follow the zone's bypass definition. This means the console will ignore any tampers that occur on a bypassed zone. Wireless PGM Supervision Options Section [294]: Options [1] to [4]; Wireless PGMs 1 to 4; Default: All ON If enabled, Magellan can wait for each of its assigned MG2WPGM transmitters to send a status signal within a specified time (see Check-in Supervision Time on page 24) to confirm their presence and functionality. If a device has not sent a signal within the specified time period or Magellan tries to communicate with the device without success, Magellan can generate a trouble, an alarm and/or transmit a report code to the monitoring station as defined by the Wireless Transmitter Supervision Options (see page 24). Section [194] determines which wireless PGMs will be supervised and which will not. Enable the option pertaining to the MG-2WPGM you wish Magellan to supervise. Paradox Magellan Systems Wireless Keypad Supervision Options Section [295]: Options [1] to [4]; Wireless keypads 1 to 4; Default: All ON If enabled, Magellan can wait for each of its assigned wireless keypads to send a status signal within a specified time (see Check-in Supervision Time on page 24) to confirm their presence and functionality. If a device has not sent a signal within the specified time period or Magellan tries to communicate with the device without success, Magellan can generate a trouble, an alarm and/or transmit a report code to the monitoring station as defined by the Wireless Transmitter Supervision Options (see page 24). Section [295] determines which wireless PGMs will be supervised and which will not. Enable the option pertaining to the wireless keypad you wish Magellan to supervise. Wireless Repeater Supervision Options Section [296]: Options [1] to [2]; Wireless repeaters 1 to 2; Default: All ON If enabled, Magellan can wait for each of its assigned wireless repeaters to send a status signal within a specified time (see Check-in Supervision Time on page 24) to confirm their presence and functionality. If a device has not sent a signal within the specified time period or Magellan tries to communicate with the device without success, Magellan can generate a trouble, an alarm and/or transmit a report code to the monitoring station as defined by the Wireless Transmitter Supervision Options (see page 24). Section [296] determines which wireless repeaters will be supervised and which will not. Enable the option pertaining to the wireless repeater you wish Magellan to supervise. Wireless PGM Console Supervision Options (Follow Alarm/Follow Bell) Section [297]: Options [1] to [4]; Wireless PGMs 1 to 4; Default: All OFF This feature allows you to further program any wireless PGM that is set to follow an alarm or bell by allowing you to also program the wireless PGM to activate following an absence of successful communication with the Magellan console. If enabled, Magellan can send a status request to each of its assigned MG-2WPGM transmitters to confirm their presence and functionality. If a device has not received a status request by the Magellan console within a specified time period, the MG-2WPGM will activate. Section [195] determines which wireless PGMs that are set to follow an alarm/bell will supervise the Magellan console. If a wireless PGM has already been programmed for console supervision, this option will be ignored. Backup Alarm Reporting Option This feature provides you with the option of supervising the communication between the Magellan console and the MG2WPGM. If enabled, the MG-2WPGM will periodically check for communication with the Magellan console. If there is no response from the console, the relay will activate. 25 When the Magellan system is in entry delay, the console will send a message to the MG-2WPGM telling it that it is in entry delay. During the entry delay, the MG-2WPGM will check for communication with the Magellan console every 10 seconds and if there is no response from the console, the relay will activate. To enable the backup reporting option: 1. Press [MENU] + [4] + [INSTALLER CODE] + [7]. 2. Using the [NEXT] key, scroll to the [CONSOLE SUPERV?] option. 3. Press [OK]. section [139]). The console will not enable its speaker or the system siren. Audible Alarm: Same as the silent alarm except that the console will enable its speaker and system siren until a user cancels the alarm (disarms) with a valid Access code or when the Bell Cut-off timer elapses (if enabled; see Bell Cut-off Timer on page 24). Pulsed Alarm (Fire Panic only): Same as the audible alarm except that the siren will be pulsed as shown in Figure 20 on page 16. Refer to Standard 24Hr. Fire Zones on page 16 for more information on a pulsed siren output. Remote Panic Disarm Lock Delay Section [078]: 001 to 255 seconds; 000 = Disabled; Default = 20 seconds Panic Alarms Section [091]: Options [1], [2] and [3] Option [1] OFF = Panic 1 (Non-Medical Emergency Panic) disabled (default) Option [1] ON = Panic 1 (Non-Medical Emergency Panic) enabled When a panic alarm is generated through the use of a remote control, the system cannot be disarmed by remote control during the Remote Panic Disarm Lock Delay. Enter the desired 3-digit delay value into section [078] to program the Remote Panic Disarm Lock Delay. Option [2] OFF = Panic 2 (Auxiliary Panic) disabled (default) Option [2] ON = Panic 2 (Auxiliary Panic) enabled Option [3] OFF = Panic 3 (Fire Panic) disabled (default) Option [3] ON = Panic 3 (Fire Panic) enabled Enable section [091] options [1], [2] and [3] to enable the system’s three panic alarms. Each panic alarm is activated by pressing two keys simultaneously and holding them down for 2 seconds. See Table 6 on page 26 for the appropriate panic alarm keys. Whether these panic alarms will generate a silent or audible alarm is determined by section [091] options [4] to [6] (see Panic Alarm Types on page 26). Table 6: Panic Alarm Keys Keys to press Panic Alarm Type [1] and [3] Panic 1 (Non-Medical Emergency Panic) [4] and [6] Panic 2 (Auxiliary Panic) [7] and [9] Panic 3 (Fire Panic) Remote controls can also be programmed to generate panic alarms. See Programming the Remote Control’s Buttons on page 20 for more information on programming remote controls to generate panic alarms. Panic Alarm Types Section [091]: Options [4], [5] and [6] Option [4] OFF = Panic 1 (Non-Medical Emergency Panic) is silent (default) Option [4] ON = Panic 1 (Non-Medical Emergency Panic) is audible Option [5] OFF = Panic 2 (Auxiliary Panic) is silent (default) Option [5] ON = Panic 2 (Auxiliary Panic) is audible Option [6] OFF = Panic 3 (Fire Panic) is silent (default) Option [6] ON = Panic 3 (Fire Panic) is pulsed Options [4] to [6] represent the alarm types of panic alarms 1 to 3 respectively. Silent Alarm: The Magellan console will emit a confirmation beep and transmit the appropriate Panic report code (if programmed in 26 Reference & Installation Manual Reporting and Dialer Settings Report Codes A report code is a 1- or 2-digit hexadecimal value consisting of digits from 1 to F. Each section from [120] to [156] represents a set of up to four specific events and each of these events can be programmed with a separate 1- or 2-digit report code. Only the Ademco Slow, Silent Knight, and Sescoa formats support 1-digit report codes. To program a 1-digit report code, press the [0] key followed by the desired hexadecimal digit or vice versa. When a specific event occurs, the console will attempt to transmit the programmed report code to the monitoring station. The method of report code transmission is defined by the Reporting Formats (see page 30) and the Event Call Direction (see page 31). These two items define how and where the report codes are transmitted. If you are using the Ademco Contact ID format, sections [120] to [156] do not have to be programmed (see Appendix 2: Ademco Contact ID Report Code List on page 41). For more information, refer to Reporting Formats (see page 30). The following sub-sections provide a brief description of the events that the Magellan console can report. Arming Report Codes Disarming Report Codes Sections [126] to [129] A report code can be programmed for each of the 16 User codes. Whenever an Access code is used to disarm the system or an alarm, the Magellan console can send the appropriate report code to the monitoring station, identifying which user disarmed the system. The Disarming and the Special Disarming report codes can be transmitted every time the system is disarmed or only when the system is disarmed after an alarm (see Disarming Reporting Options on page 33). Special Disarming Report Codes Section [130] Whenever using one of the special disarming features, the Magellan console can send the report code to the monitoring station, identifying how the system was disarmed. • • End Auto-arm: The system is disarmed during the Timed Autoarm's 60-second Exit Delay (see page 22). Only reports if Disarming Reporting Options (see page 33) are set to always report disarming. Disarm via PC: System is disarmed using the WinLoad software. Sections [120] to [123] A report code can be programmed for each of the 16 User codes. When using an Access code to arm the system, the Magellan console can send the appropriate report code to the monitoring station, identifying which user armed the system. Special Arming Report Codes Zone Alarm Report Codes Sections [131] to [138] A report code can be programmed for each of the 32 available zones. Whenever a zone generates an alarm, the console can send the appropriate report code to the monitoring station, identifying which zone generated an alarm. Sections [124] and [125] Whenever the system is armed using one of the special arming features listed below, the console can send the appropriate report code to the monitoring station identifying how the system was armed. Section [124] • • • • Timed Auto-arming: The system has armed itself at the programmed time (see page 22). Late to Close: Reports every day at the time specified by the Auto-arm Timer (see page 22). No Movement: The system has armed itself after the programmed period without movement (see No Movement Auto-Arming on page 22). Partial Arming: The system was Stay, Instant or Force Armed or armed with bypassed zones. Section [125] • • Quick Arming: The system was armed using a One-touch Arming feature (see page 23). Arming via PC: The system was armed using the WinLoad software. Zone Alarm Restore Report Codes Sections [139] to [146] A report code can be programmed for each of the 32 available zones. The Magellan console can transmit these report codes to the monitoring station identifying which zone was restored. A zone is restored when it closes after generating an alarm or once the bell has cut off after alarm generation. Please refer to Zone Alarm Restore Report Codes on page 27. Special Alarm Report Codes Sections [147] and [148] Whenever the system generates an alarm due to one of the conditions listed below, the control panel can send the appropriate report code to the monitoring station identifying the type of alarm. Section [147] • • Paradox Magellan Systems Non-Medical Emergency Panic: Panic keys [1] and [3] (see page 26) or the appropriate button(s) on a remote control (see page 20) have been pressed. Auxiliary Panic: Panic keys [4] and [6] (see page 26) or the appropriate button(s) on a remote control (see page 20) have been pressed. 27 • • Fire Panic: Panic keys [7] and [9] (see page 26) or the appropriate button(s) on a remote control (see page 20) have been pressed. Recent Closing: Reports when an alarm is generated after arming the system within the period defined by the Recent Close Delay (see page 32). • Section [167] • Section [148] • • • Auto-zone Shutdown: A zone communicates more than the programmed number of transmissions in a single armed period (see page 17). Duress: A Duress code is keyed in (see page 14). Paramedical alarm Zone Tamper Report Codes Section [149] to [156] A report code can be programmed for each of the 32 available zones. Whenever a tamper or wire fault occurs on a zone, the Magellan console can send the appropriate report code to the monitoring station identifying which zone was tampered. If Tamper Recognition (see page 24) is disabled, the console will not report the occurrence of any tampers, wire faults or tamper restores. Zone Tamper Restore Report Codes Sections [157] to [164] A report code can be programmed for each of the 32 available zones. Whenever a tampered zone is restored, the Magellan console can send the appropriate report code to the monitoring station identifying which zone has been restored. If Tamper Recognition (see page 24) is disabled, the console will not report the occurrence of any tampers, wire faults or tamper restores. Tx Supervision Loss: Check-in Supervision (see page 24) has been enabled and a transmitter is no longer communicating with the system. RF Jamming Supervision: The Magellan console has encountered RF Jamming (see RF Jamming Supervision on page 33). System Trouble Restore Codes Sections [168] to [169] Whenever the system restores one of the troubles listed in sections [165] to [167] (see System Trouble Report Codes on page 28), the Magellan console can send the appropriate report code to the monitoring station identifying the type of system trouble restored. If Telephone Line Monitoring is enabled (see page 32), use the first two digits to program a TLM Restore report code that the console can transmit. Special Reporting Codes Sections [171] and [172] Whenever the system generates one of the instances listed below, the Magellan console can send the appropriate report code to the monitoring station identifying the type of system occurrence. Section [171] • • • Cold Start: The console was completely shut down (no battery, no AC) and then was restarted. Test Report: A test report has been generated automatically (see page 32). WinLoad Logout: The console has ended communication with WinLoad. Section [172] System Trouble Report Codes Section [165] to [167] • • • Whenever the system generates one of the instances listed below, the console can send the appropriate report code to the monitoring station identifying the type of system trouble. Section [165] • • • AC Failure: Magellan has detected a loss of AC power. Transmission of this report code can be delayed (see Power Failure Report Delay on page 33). Battery Failure: The backup battery is disconnected or battery voltage is ≤ (less than or equal to) a certain voltage. Timer Loss: The console has detected a loss in time or clock failure. Wireless Module Trouble Report Codes Section [173] to [174] Whenever the system generates one of the instances listed below, the console can send the appropriate report code to the monitoring station identifying the type of wireless module trouble. Section [173] • Section [166] • • • Unit Tamper: A tamper has been detected on the console itself (see Console Tamper Supervision on page 36). Fail To Communicate: The Magellan console has failed all attempts to communicate with the monitoring station. The report code will be transmitted upon the next successful attempt. Wireless Low Battery: The battery voltage of a wireless transmitter (motion detector or contact switch) has dropped below recommended limits. Installer logon: Installer has entered the programming mode. Installer Logout: Installer has exited the programming mode. Closing Delinquency: The last time the system was armed is greater than the programmed Closing Delinquency timer (see page 23). • • • PGM Supervision Loss: The console has lost communication with a wireless PGM. PGM Tamper: The anti-tamper switch of a PGM has been triggered. Keypad Supervision Loss: The console has lost communication with a wireless keypad. Keypad Battery Trouble: The battery voltage of a keypad has dropped below recommended limits. Section [174] 28 Reference & Installation Manual • • • • Keypad AC Failure: The AC voltage of a keypad has dropped below recommended limits. Repeater Supervision Loss: The console has lost communication with a wireless repeater. Repeater Battery Trouble: The battery voltage of a repeater has dropped below recommended limits. Repeater AC Failure: The AC voltage of a repeater has dropped below recommended limits. • For more information on how these telephone numbers are used, please refer to Event Call Direction on page 31 and Reporting Formats on page 30. Also refer to Delay Between Dialing Attempts on page 31. For UL installations, the number of dialing attempts shall not exceed 10. Wireless Module Trouble Restore Codes MSTN 2 as Backup Number Section [099]: Option [1] Sections [175] to [176] Whenever the system restores one of the troubles listed in sections [173] to [174] (see System Trouble Report Codes on page 28), the Magellan console can send the appropriate report code to the monitoring station identifying the type of system trouble restored. If Telephone Line Monitoring is enabled (see page 32), use the first two digits to program a TLM Restore report code that the console can transmit. Option [1] OFF = Use MSTN 2 as a monitoring station telephone number only Option [1] ON = In UL installations, only one telephone number is allowed. For more information, please refer to Monitoring Station Telephone Numbers (MSTNs) on page 29 and Alternate Dial Option on page 31. Pager Telephone Number Section [113] The Magellan console uses the Pager telephone number programmed in section [113] to connect and communicate the numeric pager message programmed in section [114] (see Pager Reporting Message on page 29) to a pager. Pager Reporting Message Section [114]: 32-digit decimal number (0 to 9 as well as [*] and [#]) Table 7: Special Keys for Telephone Numbers Keys to press [#] Center [ACTION] (pause) key Add a 4-second pause to the telephone number. Press the key and a “P” will be inserted into the telephone number Monitoring Station Telephone Numbers (MSTNs) Section [111] = Monitoring Station Telephone Number 1 Section [112] = Monitoring Station Telephone Number 2 The Magellan console uses the MSTNs (Monitoring Station Telephone Numbers) programmed in sections [111] and/or [112] to connect and communicate with the monitoring station. The following situations also apply: • • If after eight attempts of calling one monitoring station telephone number have failed, the console will then dial the backup telephone number (if section [099] option [1] is enabled. See MSTN 2 as Backup Number on page 29). If the Alternate Dial option (see page 31) is enabled, the console will dial the programmed backup telephone number after every failed attempt (if section [099] option [1] is enabled. See MSTN 2 as Backup Number on page 29). Paradox Magellan Systems Program the desired numeric message you wish to send whenever the console dials the Pager telephone number in section [114]. If the message is less than 32 digits, press the left [ACTION] key (OK) to save the message. Action or Value [*] MSTN 2 can be used a backup telephone number (default) MSTN 2 can also be used as a backup telephone number. If section [099] option [1] is enabled (ON) the console will use MSTN 2 as a backup telephone number. Console Telephone Numbers Magellan can dial up to two different monitoring station telephone numbers and one Pager telephone number. You can enter any digit from 0 to 9 and any special keys or functions (see Table 7 on page 29) up to a maximum of 32 digits. If the number is less than 32 digits, press the left [ACTION] key (OK) to save the message. If no backup telephone number is programmed, the console will never report to the backup telephone number. Voice Message Telephone Numbers The Magellan console will use up to five Voice Message telephone numbers (which are programmed in the Installer menu; refer to the Magellan Quick Setup Guide for more information) to play a pre-recorded message to an external telephone or cellular telephone. Please note the following when programming and using this feature: • • • The console will only dial a Voice Message telephone number when the system is in alarm. The console begins with the first programmed Voice Message telephone number. When the call is connected, the console will play the prerecorded message and the zone labels of all the zones that are in alarm. Once the telephone call from the Magellan console is received, the [#] key on the telephone can be pressed twice to acknowledge and end the message or the [1] can be pressed to use the speakerphone feature* and talk through the Magellan console. The [2] key can be pressed to disarm the system. The console will ask for an access code, and if granted, will disarm the system and enter Access Mode. 29 • • • • The console will repeat the message a programmed amount of times (see Voice Message Repetitions on page 30) if no acknowledgement is immediately received. If no acknowledgement is received before the number of repetitions has elapsed, the console will then call the next programmed Voice Message telephone number and repeat the process. After calling the last programmed Voice Message telephone number without an acknowledgement, the console will once again call the first Voice Message telephone number and repeat the process a maximum of three times. If no acknowledgement is received after the third time, the console will generate a Fail to Comm. event and trouble. * The speakerphone feature is only available with the MG-6160. Voice Message Repetitions Section [079]: 001 to 010 repetitions; Default = 3 repetitions; Maximum = 10 repetitions This feature determines the amount of times the console will repeat the pre-recorded message played with the Voice Message telephone number without receiving an acknowledgement. Enter any 3-digit number from 001 to 010 into section [079] to program the Voice Message Repetitions feature. Service Telephone Number Section [116] When a specific trouble occurs (Fail to Comm., Console Tamper or Supervision Loss), the console will offer you the option of calling the telephone number programmed in section [116]. After selecting the option, the console becomes a speakerphone*. * The speakerphone feature is only available with the MG-6160. Refer to the Magellan User Guide for more information on using this feature. Utility Reporting Within the Utility Reporting menu, customize what events and when these events will be reported to the user. One of five report types can be programmed to have the Magellan console call the user on up to two different telephone numbers with a prerecorded voice message when certain conditions are met. Once the telephone call from the Magellan console is received, the [#] key on the telephone can be pressed twice to acknowledge and end the message or the [1] can be pressed to use the speakerphone feature* and talk through the Magellan console. * The speakerphone feature is only available with the MG-6160. To program the Utility Reporting feature using the Magellan console: 1. Press [MENU] and then press the [4] key. 2. Enter the [INSTALLER CODE] and then press the [3] key. 3. Press [NEXT] until the Utility Reporting screen appears, then press [OK]. 4. Press [NEXT] until the desired telephone number appears, then press [OK]. 5. Enter the desired telephone number and then press [OK] twice. 30 6. Press [NEXT] until the desired report type appears, then press [OK] (see Report Types on page 30). 7. Press [NEXT] until the Record Alrm Mes? screen appears, then press [OK]. 8. Record the alarm message. Report Types There are four report types that can be used with Utility Reporting. • Disarm with user: The Magellan console calls the user when specific users disarm the system. • System troubles: The Magellan console calls the user when specific troubles appear. • Paramedic alarm: The Magellan console calls the user when specific users require non-medical emergency assistance and press the appropriate key on their remote controls. • Zone activation: The Magellan console calls the user when a specific zone is breached or opened. • Panic: There are four types of panic: Emergency, Auxiliary, Fire, and Duress Alarm. Refer to the Magellan User Guide for more information on using this feature. Console Account Number Section [107] All report codes are preceded by a 4-digit or 3-digit Console Account Number to ensure correct identification of the Magellan console. The Console account number can be any hexa-digit from 1 to F. To enter a 3-digit account number, simply press the [1] key from the center keypad, followed by the 3-digit account number. Also, when using 3-digit account numbers, you must use 1-digit report codes. Reporting Formats Section [105] = Reporting format for MSTN 1 Section [106] = Reporting format for MSTN 2 The reporting formats apply only to the MSTNs (Monitoring Station Telephone Numbers) programmed in sections [111] and [112] (page 29) The Magellan console can use a number of different reporting formats and each monitoring station telephone number can be programmed with a different reporting format. The three digits entered into section [105] represent the reporting format used to communicate with Monitoring Station Telephone Number 1 while the three digits entered into section [106] represent the reporting format used to communicate with Monitoring Station Telephone Number 2. Table 8: Reporting Formats 3-digit Value Reporting Format 001 Ademco slow (1400Hz, 1900Hz, 10BPS) 002 Silent Knight Fast (1400Hz, 1900Hz, 10BPS) 003 SESCOA (2300Hz, 1800Hz, 20BPS) 004 Ademco Contact ID Reference & Installation Manual 005 SIA FSK 006 Ademco Express (DTMF 4+2) UL Note: The installer is required to verify the complete compatibility of the DAC Receiver and formats at least once per year. If you are using any report format other than SIA in sections [105] and [106] and you would like to transmit an “A”, press [0] on the main keypad; if you would like to enter a space (non-reportable digit), press the [1] key on the center keypad. Standard Pulse Formats The Magellan console can use the Ademco slow, Silent Knight and SESCOA standard pulse reporting formats (see Table 8 on page 30). Option [1] ON = Call MSTN 1 Option [2] ON = Call MSTN 2 Option [3] ON = Call Pager telephone number The events are divided into five groups (see above) where each event group can be programmed to dial up to three telephone numbers (MSTN 1 & 2 and the Pager telephone number) with one as a possible backup (see MSTN 2 as Backup Number on page 29). • • • Ademco Contact ID Ademco Contact ID is a fast communicator format that uses tone reporting instead of pulse reporting. This communicator format also uses a pre-defined list of industry standard messages and report codes that will suit most of your basic installation needs. • • To manually program the report codes, use the 2-digit hexadecimal values from Appendix 2: Ademco Contact ID Report Code List on page 41. Enter 00 to disable reporting or FF to use the default report code from Appendix 1: Automatic Report Code List on page 39. SIA FSK SIA FSK is a fast communicator format that uses tone reporting instead of pulse reporting. This communicator format uses a predefined list of industry standard messages and report codes that will suit most basic installation needs. Please refer to Appendix 1: Automatic Report Code List on page 39 for a complete list of the format’s pre-defined industry standard messages and report codes. • When a reportable event occurs in the system, the Magellan console will begin dialing the numbers sequentially starting from MSTN 1 (if enabled), skipping any disabled numbers and stopping once all selected telephone numbers have been called. After eight failed attempts at trying to call the monitoring station, the console will then dial the selected backup telephone number (if enabled; see MSTN 2 as Backup Number on page 29). If the Alternate Dial option (see page 31) is enabled, the console will dial the programmed backup telephone number (if enabled, see MSTN 2 as Backup Number on page 29) after every failed attempt. If no backup telephone number is programmed or section [099] option [1] is disabled (OFF, see page 31), the console will never report to the backup telephone number. For more information, please refer to Monitoring Station Telephone Numbers (MSTNs) on page 29, Alternate Dial Option on page 31, MSTN 2 as Backup Number on page 29 and Delay Between Dialing Attempts on page 31. Example: The system is armed and zone 1 has been breached causing an alarm. If options [5] and [7] are OFF and option [6] is ON in section [100], the console will attempt to communicate with MSTN 2 in order to transmit the Zone 1 Alarm Report Code programmed in section [131]. Delay Between Dialing Attempts Section [076]: 001 to 255 seconds; 000 = disabled; Default = 20 seconds This delay determines the amount of time the Magellan console will wait between each dialing attempt. Event Call Direction Section [100]: Options [1] to [3]; Arming/Disarming Option [1] ON = Call MSTN 1 Option [2] ON = Call MSTN 2 Option [3] ON = Call Pager telephone number Section [100]: Options [5] to [7]; Alarm/Alarm Restore Option [5] ON = Call MSTN 1 Option [6] ON = Call MSTN 2 Option [7] ON = Call Pager telephone number Section [101]: Options [1] to [3]; Tamper/Tamper Restore Option [1] ON = Call MSTN 1 Option [2] ON = Call MSTN 2 Option [3] ON = Call Pager telephone number Section [101]: Options [5] to [7]; Trouble/Trouble Restore Option [5] ON = Call MSTN 1 Option [6] ON = Call MSTN 2 Option [7] ON = Call Pager telephone number Alternate Dial Option Section [098]: Option [5] Option [5] OFF = Alternate dial disabled (default) Option [5] ON = Alternate dial enabled With option [5] OFF, the Magellan console will dial the programmed backup telephone number MSTN 2 (see MSTN 2 as Backup Number on page 29) only after all attempts to call MSTN 1 have failed. With option [5] ON, the console will dial the backup telephone number after every failed attempt. Force Dial Option Section [098]: Option [6] Option [6] OFF = Force dial disabled Option [6] ON = Force dial enabled (default) Section [102]: Options [1] to [3]; Special Paradox Magellan Systems 31 When option [6] is enabled, the Magellan console will dial a telephone number even if no dial tone is present after 3 seconds. Table 9: Telephone Line Monitoring Options Options [2] OFF OFF TLM disabled (default) OFF ON Trouble only: Upon a line test failure, a TLM trouble will appear in the console’s Trouble Display. ON OFF Alarm if System Armed: Upon a line test failure, a TLM trouble will appear in the console’s Trouble Display and if the system is armed, the console will generate an alarm. ON ON Silent Alarm becomes Audible: Upon a line test failure, a TLM trouble will appear in the console’s Trouble Display and causes a silent zone or silent panic alarm to switch to audible. Dialing Method Section [098]: Option [7] Option [7] OFF = Pulse dialing Option [7] ON = Tone / DTMF dialing (default) When option [4] is ON, the Magellan console is set for Tone/ DTMF dialing. When option [4] is OFF, the console is set for pulse dialing. Refer to Pulse Ratio on page 32 for information on setting the pulse ratio. Pulse Ratio Section [098]: Option [8] Option [8] OFF = European Pulse Ratio of 1:2 Option [8] ON = U.S.A. Pulse Ratio of 1:1.5 (default) When using Pulse dialing, you can select one of two Pulse Ratios. Although most European countries use the 1:2 pulse ratio, the 1:1.5 ratio may provide better results in some cases. The same applies for North American countries. If the 1:1.5 pulse ratio is not providing the desired results, the 1:2 ratio may be used. Description [1] Please note that when the dialer detects an incoming call, the TLM test will stop for 1 minute. If transmission is used off premises, telephone line monitoring must be used in UL installations. TLM Fail Timer Section [073]: 001 to 255 seconds; 000 = Disabled; Default = 32 seconds If TLM does not detect the existence of a telephone line for the duration of this period, the control panel will generate the condition(s) defined by the TLM options (see Telephone Line Monitoring (TLM) on page 32). Switch to Pulse Dialing on 5th Attempt Section [098]: Option [3] Option [3] OFF = Switch to pulse dialing on fifth attempt disabled (default) Option [3] ON = Switch to pulse dialing on fifth attempt enabled When section [098] option [3] is ON, the Magellan console switches from tone/DTMF dialing to pulse dialing on the fifth attempt to report events to the monitoring station. The console continues to use pulse dialing until it establishes communication. When the console switches to another MSTN, it returns to tone/ DTMF dialing and will once again switch to pulse dialing on the fifth attempt. Telephone Line Monitoring (TLM) Section [098]: Options [1] and [2] When enabled, the system verifies the existence of a telephone line once every second. A line test failure occurs when the TLM detects less than a certain voltage for the period defined by the TLM Fail Timer (see page 32). If the line test fails, the Magellan console generates one or more conditions as defined by the TLM settings below. These will be restored when the console detects the telephone line again. 32 Recent Close Delay Section [066]: 001 to 255 seconds; 000 = Disabled; Default = Disabled If after having armed the system, an alarm is generated within the period defined by the Recent Close Delay, the Magellan console will attempt to transmit the Recent Close report code programmed in section [139] (page 27). Auto-Test Report Section [071]: 001 to 255 days; 000 = Disabled; Default = Disabled Section [084]: Time (HH:MM) The Magellan console will transmit the Test Report report code programmed into section [153] after the number of days programmed into section [071] has elapsed at the time programmed into section [084]. Use the 24-hour clock to program the time (i.e. 6:30PM = 18:30). The first Test Report will be transmitted within 24 hours after the feature is enabled at the time programmed in [084]. Example: Section [071] = 005 and section [084] = 13:00. The first Test Report will be sent at 1 PM that day and then the report will be sent every 5 days at 1 PM. Reference & Installation Manual Power Failure Report Delay Section [070]: 001 to 255 minutes; 000 = Disabled; Default = 15 minutes The Magellan console will transmit the AC Failure report code programmed in section [149] after the Power Failure Report Delay period has elapsed. Disarm Reporting Options Section [093]: Option [5] Option [5] OFF = Always report disarming Option [5] ON = Report disarming only after alarm (default) With option [5] OFF, the Magellan console will send the Disarming report codes (see page 27) to the monitoring station every time the system is disarmed. With option [5] ON, the console will send the Disarming report codes to the monitoring station when the system is disarmed following an alarm. Zone Restore Report Options Section [094]: Option [2] Option [2] OFF = Report on Bell Cut-Off (default) Option [2] ON = Report on zone closure With option [2] OFF, the Magellan console will send the Zone Alarm Restore report codes (see page 27) to the monitoring station when the zone has returned to normal and the Bell CutOff Timer (see page 24) has elapsed. With option [2] ON, the console will send the Zone Alarm Restore report codes to the monitoring station as soon as the zone returns to normal or when the system is disarmed. RF Jamming Supervision Section [096]: Option [8] Option [8] OFF = RF Jamming Supervision disabled Option [8] ON = RF Jamming Supervision enabled (default) With option [8] ON, a trouble will be generated when the Magellan console’s RF signal is jammed or encounters interference for a minimum of 10 seconds. This feature must be enabled for use in UL installations. Paradox Magellan Systems 33 Programmable Outputs A PGM is a programmable output that toggles to its opposite state (i.e. a normally open PGM will close) when a specific event has occurred in the system. For example, a PGM can be used to activate bells or strobe lights, open/close garage doors and much more. When a PGM activates, the control panel triggers any device or relay connected to it. The Magellan console includes two onboard PGMs. It can support up to a total of four PGMs (e.g., two onboard PGMs + two wireless PGMs OR four wireless PGMs). Assigning PGMs Sections [235] to [238]: PGMs 1 to 4 Sections [235] to [238] represent PGMs 1 to 4. A PGM module assigned to a section ([235] to [238]) will be assigned to the PGM represented by the section. Onboard PGM Activation Event Section [086] = PGM1 Activation Event Section [088] = PGM2 Activation Event This feature allows you to program the Magellan console to activate a PGM when a specific event occurs in the system. The PGM will remain in its active state until the programmed PGM Deactivation Event (see page 34) occurs or when the PGM Delay (see page 34) elapses. To program a PGM Activation Event: 1. 2. 3. The AC Loss PGM event (Event Group #28, Event Sub-group #01) will only occur after the Power Failure Report Delay elapses (see page 33). For example, a PGM module assigned to section [235] will be assigned to PGM1. For the Event List, see the PGM Table in the Magellan Programming Guide. To assign a PGM: 1. Access the installer programming mode (see page 13). 2. Enter the [SECTION] corresponding to the desired zone. 3. Enter the 6-digit [SERIAL NUMBER] of the PGM module. The serial number is located on the inside of the PGM module. The PGM module must be activated once having been assigned to the Magellan console. To activate a PGM module, insert the batteries and close the cover. PGM 1 and 2 are onboard. PGM 3 and 4 are wireless. Onboard PGM Deactivation Event Section [087] = PGM1 Section [089] = PGM2 After PGM activation (see Onboard PGM Activation Event on page 34), the PGM will return to its normal state (deactivate) when the programmed PGM Deactivation Event occurs. To program a Deactivation Event: 1. Setting PGM Function This feature allows you to program the Magellan console to recognize PGM1 and/or PGM2 as a hardwire PGM (onboard) and PGM 3 and/or 4 as wireless. To set a PGM’s function: 1. Press [MENU] + [4] + [INSTALLER CODE] + [7]. 2. Press [OK] to set the function of PGM1 or [NEXT] to set the function of PGM 2, 3, and/or 4. Press [OK] to set the function of the desired PGM module. 3. Press [YES] to set the PGM as wireless. 4. Open and then close the cover of the wireless PGM module. The PGM function has been set. 5. To continue programming the module, follow the instructions on the Magellan console. To program the PGM’s activation event and/or deactivation event, see Onboard PGM Activation Event on page 34, Wireless PGM Activation Event on page 35, Onboard PGM Deactivation Event on page 34 and Wireless PGM Deactivation Event on page 35. If both PGM1 and PGM2 are set as hardwire (onboard), Magellan will ignore sections [260] to [267], and [280] to [283]. Enter the section that corresponds to the desired PGM; PGM1 = [086], PGM2 = [088]. Enter the [EVENT GROUP #]. Enter the [SUB-GROUP #]. 2. 3. Enter section that represents the desired PGM; PGM1 = [087], PGM2 = [089]. Enter the [EVENT GROUP #]. Enter the [SUB-GROUP #]. A PGM can also be set to deactivate after a programmed period elapses (see Onboard PGM Delay on page 34). If using the PGM Delay, sections [087] and [089] can be used as an additional PGM Activation Event. For the complete Event List, see the PGM Table in the Magellan Programming Guide. Onboard PGM Delay Section [068] = PGM1, Section [069] = PGM2 001 to 255 seconds; 000 = Follow Deactivation Event; Default = 5 seconds Instead of deactivating the PGM on the occurrence of a specific event, the PGM will deactivate after the period programmed in here has elapsed. Enter 000 to have the PGMs deactivate with a PGM Deactivation Event (see page 34). If a PGM Delay is programmed, the corresponding PGM Deactivation Event can be used as an additional PGM Activation Event. 34 Reference & Installation Manual PGM Normal State (Onboard Only) Wireless PGM Deactivation Event Section [090]: Options [7] (PGM1) and [8] (PGM2) Option [7] OFF = PGM1 Normally Open (default) Option [7] ON = PGM1 Normally Closed Section [261] = Wireless PGM1 Deactivation Event Section [263] = Wireless PGM2 Deactivation Event Section [265] = Wireless PGM3 Deactivation Event Section [267] = Wireless PGM4 Deactivation Event Option [8] OFF = PGM2 Normally Open (default) Option [8] ON = PGM2 Normally Closed A PGM toggles to its opposite state (i.e. a normally open PGM will close) when a specific event has occurred in the system. You can program each PGM output to be normally open (N.O.) or normally closed (N.C.) by enabling or disabling options [7] and [8] in section [090]. PGM X10 Option (MG-6160 Only / Onboard Only) After a Wireless PGM activation (see Wireless PGM Activation Event on page 35), the wireless PGM will return to its normal state (deactivate) when the programmed Wireless PGM Deactivation Event occurs. To program a Wireless Deactivation Event: 1. 2. 3. Enter section that represents the desired wireless PGM; Wireless PGM1 = [261], Wireless PGM2 = [263], Wireless PGM3 = [265], Wireless PGM3 = [267]. Enter the [EVENT GROUP #]. Enter the [SUB-GROUP #]. Section [091]: Options [7] (PGM1) and [8] (PGM2) Option [7] OFF = PGM1 used as programmable output (default) Option [7] ON = PGM1 used as X10 output 7 A wireless PGM can also be set to deactivate after a programmed period elapses (see Wireless PGM Delay on page 35). If using the Wireless PGM Delay, sections [280] to [283] can be used as a second Wireless PGM Activation Event. Option [8] OFF = PGM2 used as programmable output (default) Option [8] ON = PGM2 used as X10 output 8 For the complete Event List, see the PGM Table in the Magellan Programming Guide. With section [091] options [7] and [8] enabled (ON), PGMs 1 and 2 will follow the ON/OFF state of X10 outputs 7 and 8. Therefore the PGMs will function as follows: • • When X10 output 7 is enabled, PGM1 will activate. When X10 output 7 is disabled, PGM1 will deactivate. When X10 output 8 is enabled, PGM2 will activate. When X10 output 8 is disabled, PGM2 will deactivate. When section [091] options [7] and [8] are enabled, the PGM outputs will disregard their PGM activation and deactivation events (sections [086] to [089]). Wireless PGM Activation Event Section [260] = Wireless PGM1 Activation Event Section [262] = Wireless PGM2 Activation Event Section [264] = Wireless PGM3 Activation Event Section [266] = Wireless PGM4 Activation Event This feature allows you to program the MG-2WPGM modules to activate a wireless PGM when a specific event occurs in the system. The wireless PGM will remain in its active state until the programmed Wireless PGM Deactivation Event (see page 35) occurs or when the Wireless PGM Delay (see page 35) elapses. To program a Wireless PGM Activation Event: 1. 2. 3. Wireless PGM Delay Section [280] = Wireless PGM1, Section [281] = Wireless PGM2 Section [282] = Wireless PGM3, Section [283] = Wireless PGM4 000 = Follow Deactivation Event; 001 = 1s delay; 002 = 5s delay; 003 = 15s delay; 004 = 30s delay; 005 = 1min delay; 006 = 5min delay; 007 = 15min delay; 008 = 30min delay; Default = 000 Instead of deactivating the wireless PGM on the occurrence of a specific event, the wireless PGM will deactivate after the period programmed in here has elapsed. Enter 000 to have the wireless PGMs deactivate with a Wireless PGM Deactivation Event (see page 35). If a Wireless PGM Delay is programmed, the Wireless PGM Deactivation Event can be used as a second Wireless PGM Activation Event. Enter the section that corresponds to the desired wireless PGM; Wireless PGM1 = [260], Wireless PGM2 = [262], Wireless PGM3 = [264], Wireless PGM3 = [266]. Enter the [EVENT GROUP #]. Enter the [SUB-GROUP #]. The AC Loss PGM event (Event Group #28, Event Sub-group #01) will only occur after the Power Failure Report Delay elapses (see page 33). For the Event List, see the PGM Table in the Magellan Programming Guide. Paradox Magellan Systems 35 System Settings Software Reset Section [199] With section [093] option [8] ON, the Magellan’s radio is turned ON automatically after the system is armed (after the Exit Delay Timer has elapsed). Performing a software reset will reset all programmed sections back to the factory defaults. To perform a software reset: 1. 2. Access the installer programming mode (see page 13). Enter section [199]. You can also perform a software reset by removing power to the console, pressing and holding down the [*] and [#] keys and then reapplying power to the console. Installer Lock Section [180]: 000 = Disabled; 147 = Lock Enabled; Default = Disabled Program 147 into section [180] to lock all programming. Performing a hardware reset will not affect the current console settings. To remove the Installer Lock, enter 000. Console Tamper Supervision Section [090]: Option [5] Option [5] OFF = Console Tamper Supervision disabled (default) Option [5] ON = Console Tamper Supervision enabled Magellan can be programmed to monitor its on-board tamper status. The console will follow its programmed Tamper Recognition options. Refer to Tamper Recognition Options on page 24 for more information. Daylight Savings Time Section [096]: Option [5] Option [5] OFF = Daylight Savings Time disabled (default) Option [5] ON = Daylight Savings Time enabled With section [096] option [5] ON, Magellan adjusts the system’s clock (time) for daylight savings changes. At 2:00AM on the first Sunday of a full weekend in April, the console will add one hour to the programmed time (clock). At 2:00 AM on the last Sunday of a full weekend in October, the console will subtract one hour from the programmed time (clock). AC Power Failure Warning Section [096]: Option [6] Option [6] OFF = AC Power Failure Warning disabled (default) Option [6] ON = AC Power Failure Warning enabled With this feature enabled, the console emits an intermittent beep tone whenever an AC power failure is detected. The intermittent beep tone remains activated until the user enters the Trouble Display by pressing the left [ACTION] key (i). The intermittent beeps will re-initialize whenever the trouble occurs or the trouble restores and re-occurs. This feature must be enabled in UL installations. Console Audible Trouble Warning The Trouble Display Section [090]: Option [2] Option [2] OFF = Console beep on trouble disabled (default) Option [2] ON = Console beep on trouble enabled When the system experiences problems or is tampered with, the When enabled, the console emits an intermittent beep tone whenever a trouble condition occurs in the system. The intermittent beep tone remains activated until the user enters the Trouble Display by pressing the left [ACTION] key (I). The intermittent beeps will re-initialize whenever a new trouble occurs or the trouble restores and re-occurs. The only trouble not covered by this feature is the AC Power Failure trouble. See AC Power Failure Warning on page 36. Information symbol ( ) will appear on the LCD screen and the light will illuminate. The potential troubles that the Magellan system can experience are listed below. To access the Trouble Display: 1. 2. 3. Press the key. Use the [NEXT] key to scroll through the displayed troubles. Press the [OK] key to view details on the desired trouble. Trouble Description Bypass There is a zone (or zones) that is bypassed in the system. Alarm Memory An alarm has occurred in the system. The zones displayed went into alarm. Console Low Bat The backup battery pack is disconnected or needs to be recharged or replaced. Doorbell Low Bat Wireless transmitter being used as a doorbell (see page 19) requires its batteries changed. Zone Low Battery Zone(s) displayed indicate(s) where a wireless transmitter’s battery needs to be replaced. This feature must be enabled in UL installations. FM Tuner Option (MG-6160 only) Section [093]: Option [8] Option [8] OFF = FM tuner is disabled when the system is armed (default) Option [8] ON = FM tuner is enabled when system is armed 36 Reference & Installation Manual Trouble Description Clock Loss The time and date were reset to default. To reprogram: 1. Press the [12HRS] key to display the time using the 12-hour clock or the [24HRS] key to display the time using the 24-hour clock. 2. Enter the desired time and then press [OK]. 3. Enter the date and then press [OK]. AC Failure Power failure detected. The system is running on the backup battery pack. Supervision Trouble Zone(s) and/or wireless output(s) displayed has/have not sent a check-in signal within the programmed interval (see page 24). Console Tamper The Magellan console was tampered with. Zone Tamper Zone(s) and/or wireless output(s) displayed was/were tampered with. Fail to Communicate with Central* The Magellan console has failed to contact the monitoring station. Fail to Communicate with Voice Reporting* The Magellan console has failed to contact telephone number programmed for Voice reporting. Fail to Communicate to Pager* The Magellan console has failed to contact telephone number programmed for Pager reporting. Fail to Communicate with PC* The Magellan console is unable to communicate with the WinLoad software. Fail to Communicate with Voice Utility* The Magellan console has failed to contact telephone number programmed for Voice Utility reporting. * When a communication failure trouble is acknowledged by pressing [OK], you will be given the option to call your service provider. See Service Telephone Number on page 30. Paradox Magellan Systems 37 WinLoad Software Settings Panel Answer Options The following two options define how Magellan answers an incoming call from a computer using the WinLoad Installer Upload/Download Software. Answering Machine Override Section [074]: 010 to 255 seconds; 000 = disabled; Default = disabled When using WinLoad to communicate remotely with an installation site that uses an answering machine or service, the answering machine override must be programmed. Using WinLoad, you will call Magellan, hang up, then call back. If the installation site is called back within the delay programmed in section [074], the console will override the answering machine or service by picking up the line after the first ring on the second call. You must wait at least 10 seconds before attempting the second call, otherwise, the console will think it is the same call. For details on how to use WinLoad, refer to the WinLoad On-line Help. PC Telephone Number Section [115] Magellan will dial the number programmed in section [118] when trying to initiate communication with a computer using WinLoad. You can enter any digit from 0 to 9 and any special keys or functions (see Table 7 on page 29) up to a maximum of 32 digits. Call Back Feature Section [098]: Option [4] Option [4] OFF = Call Back Feature disabled (default) Option [4] ON = Call Back Feature enabled The Call Back feature provides additional security. When section [098] option [4] in ON and a computer using WinLoad attempts to communicate with Magellan, the console hangs up and calls the computer back to re-verify identification codes and re-establish communication. When Magellan hangs up, WinLoad automatically goes into Wait for Call mode, ready to answer when the console calls back. The PC Telephone number must be programmed (see PC Telephone Number on page 38). Example: A security installation is using an answering machine set to answer after three rings. If section [074] has been programmed with 040 (40 seconds) and the second call is made within 40 seconds, Magellan will pick up the line on the first ring. If it takes more than 40 seconds, the console will not answer on the first ring and the answering machine will answer after three rings. Number of Rings Section [072]: 001 to 015 rings; 000 = disabled; Default = 008 This value represents the number of rings Magellan will wait before picking-up the line. If the line is not answered after the number of programmed rings, the console will answer the call. You must wait at least 10 seconds before attempting the second call or Magellan will think it is the same call. Panel Identifier Section [108]: 4-digit Hexadecimal number from 0000 to FFFF This 4-digit code identifies the console to WinLoad before initiating communication. Magellan will verify that the Panel Identifier in the WinLoad software is the same as the code programmed in section [108]. If the codes do not match, the console will not establish communication. Therefore, be sure to program the same panel identifier code into both Magellan and WinLoad. PC Password Section [109]: 4-digit Hexadecimal number from 0000 to FFFF This 4-digit password identifies the PC to Magellan before establishing communication. Program the same PC password into both the console and WinLoad. If the passwords do not match, WinLoad will not establish communication. 38 Reference & Installation Manual Appendix 1: Automatic Report Code List System Event Default Contact ID Report Code when using sections [790] to [795] Default SIA Report Code when using sections [790] to [795] Arming with Master Code (##) 3 4A1 - Close by user CL - Closing Report Arming with User Code (##) 3 4A1 - Close by user CL - Closing Report Arming with Keyswitch (##) 3 4A9 - Keyswitch Close CS - Closing Keyswitch Auto Arming 3 4A3 - Automatic Close CA - Automatic Closing Arm with PC software 3 4A7 - Remote arm/disarm CL - Closing Report Late To Close 3 4A4 - Late to Close OT - Late to Close No Movement 3 4A4 - Late to Close NA - No Activity Partial arming 1 574 - Group bypass CG - Close Area Quick arming 3 408 - Quick arm CL - Closing Report Closing Delinquency 1 654 - System Inactivity CD - System Inactivity Disarm with Master Code (##) 1 4A1 - Open by user OP - Opening Report Disarm with User Code (##) 1 4A1 - Open by user OP - Opening Report Disarm with Keyswitch (##) 1 4A9 - Keyswitch Open OS - Opening Keyswitch Disarm after alarm* with Master Code (##) 1 4A1 - Open by user OP - Opening Report Disarm after alarm* with User Code (##) 1 4A1 - Open by user OP - Opening Report Disarm after alarm* with Keyswitch (##) 1 4A1 - Keyswitch Open OS - Opening Keyswitch Cancel alarm** with Master Code (##) 1 4A6 - Open by user OR - Disarm from Alarm Cancel alarm** with User Code (##) 1 4A6 - Open by user OR - Disarm from Alarm Cancel alarm** with Keyswitch (##) 1 4A6 - Keyswitch Open OS - Opening Keyswitch Auto Arming Cancellation 1 4A5 - Deferred Open/Close CE - Closing Extend Disarm with PC software 1 4A7 - Remote arm/disarm OP - Opening Report Disarm after an alarm with PC software 1 4A7 - Remote arm/disarm OR - Disarm From Alarm Quick disarm 1 408 - Quick disarm OP - Opening Report Zone Bypassed (##) 1 57A - Zone bypass UB - Untyped Zone Bypass Zone alarm (##) 1 13A - Burglary Alarm BA - Burglary Alarm Fire alarm (##) 1 11A - Fire alarm FA - Fire Alarm Zone alarm restore (##) 3 13A - Burglary Alarm Restore BH - Burglary Alarm Restore Fire alarm restore (##) 3 11A - Fire alarm Restore FH - Fire Alarm Restore Panic 1 - Non-Medical Emergency 1 12A - Panic alarm PA - Panic Alarm Panic 2 - Medical 1 1AA - Medical alarm MA - Medical Alarm Panic 3 - Fire 1 115 - Pull Station FA - Fire Alarm Recent closing 3 4AA - Open/Close CR - Recent Closing Global zone shutdown 1 574 - Group bypass CG - Close Area Duress alarm 1 121 - Duress HA - Hold-up Alarm Zone shutdown (##) 1 57A - Zone bypass UB - Untyped Zone Bypass Zone tampered (##) 1 144 - Sensor tamper TA - Tamper Alarm Zone tamper restore (##) 3 144 - Sensor tamper restore TR - Tamper Restoral Keypad Lockout 1 421 - Access denied JA - User Code Tamper * An armed system is or was in alarm and was disarmed by a user. ** A disarmed system is or was in alarm (e.g. 24Hr. zone) and was disarmed by a user. Paradox Magellan Systems 39 System Event Default Contact ID Report Code when using sections [790] to [795] Default SIA Report Code when using sections [790] to [795] AC Failure 1 3A1 - AC loss AT - AC Trouble Battery Failure 1 3A9 - Battery test failure YT - System Battery Trouble Auxiliary supply trouble 1 3AA - System trouble YP - Power Supply Trouble Bell output current limit 1 321 - Bell 1 YA - Bell Fault Bell absent 1 321 - Bell 1 YA - Bell Fault Clock lost 1 626 - Time/Date inaccurate JT - Time Changed Fire loop trouble 1 373 - Fire trouble FT - Fire Trouble TLM trouble restore 3 351 - Telco 1 fault restore LR - Phone Line restoral AC Failure restore 3 3A1 - AC loss restore AR - AC Restoral Battery Failure restore 3 3A9 - Battery test restore YR - System Battery Restoral Auxiliary supply trouble restore 3 3AA - System trouble restore YQ - Power Supply restored Bell output current limit restore 3 321 - Bell 1 restore YH - Bell Restored Bell absent restore 3 321 - Bell 1 restore YH - Bell Restored Clock programmed 3 625 - Time/Date Reset JT - Time Changed Fire loop trouble restore 3 373 - Fire trouble restore FJ - Fire Trouble Restore Combus fault 1 333 - Expansion module failure ET - Expansion Trouble Module tamper 1 145 - Expansion module tamper TA - Tamper Alarm Module ROM_RAM_error 1 3A4 - Rom checksum bad YF - Parameter Checksum Fail Module TLM trouble 1 352 - Telco 2 fault LT - Phone Line trouble Module fail to communicate to monitoring station. 1 354 - Fail to communicate YC - Communication Fails Printer fault 1 336 - Local printer failure VT - Printer Trouble Module AC Failure 1 3A1 - AC loss AT - AC Trouble Module battery failure 1 3A9 - Battery test failure YT - System Battery Trouble Module Auxiliary supply trouble 1 3AA - System trouble YP - Power Supply Trouble Bus fault restore 3 333 - Expansion module failure restore ER - Expansion Restoral Module tamper restore 3 145 - Expansion module tamper restore TR - Tamper Restoral Module ROM_RAM_error restore 3 3A4 - Rom checksum bad restore YG - Parameter Changed Module TLM restore 3 352 - Telco 2 fault restore LR - Phone Line Restoral Printer fault restore 3 336 - Local printer failure restore VR - Printer Restore Module AC restore 3 3A1 - AC loss restore AR - AC Restoral Module battery restore 3 3A9 - Battery test failure restore YR - System Battery Restoral Module Auxiliary supply restore 3 3AA - System trouble restore YQ - Power Supply Restored Fail to communicate with monitoring station 1 354 - Fail to communicate YC - Communication Fails Module RF low battery 1 384 - RF transmitter low battery XT - Transmitter Battery Trouble Module RF battery restore 3 384 - RF transmitter battery restore XR - Transmitter Battery Restoral Module RF supervision trouble 1 381 - Loss of supervision - RF US - Untype Zone Supervision Module RF supervision restore 3 381 - Supervision restore - RF UR - Untyped Zone Restoral Cold Start 1 3A8 - System shutdown RR - Power Up Warm Start 1 3A5 - System reset YW - Watchdog Reset Test Report engaged 1 6A2 - Periodic test report TX - Test Report PC software communication finished 1 412 - Successful - download access RS - Remote Program Success Installer on site 1 627 - Program mode Entry LB - Local Program Installer programming finished 1 628 - Program mode Exit LS - Local Program Success 40 Reference & Installation Manual Appendix 2: Ademco Contact ID Report Code List CID# Reporting Code Programming Value Medical Alarms - 100 100 Medical alarm 01 101 Pendant transmitter 02 102 Fail to report in 03 Fire Alarms - 110 CID# Reporting Code Programming Value 154 Water leakage 29 155 Foil break 2A 156 Day trouble 2B 157 Low bottled gas level 2C 158 High temperature 2D 159 Low temperature 2E 110 Fire alarm 04 161 Loss of air flow 2F 111 Smoke 05 162 Carbon monoxide detected 30 112 Combustion 06 163 Tank level 31 113 Water flow 07 114 Heat 08 115 Pull station 09 116 Duct 0A 117 Flame 0B 118 Near alarm 0C Panic Alarms - 120 120 Panic alarm 0D 121 Duress 0E 122 Silent 0F 123 Audible 10 124 Duress - Access granted 11 125 Duress - Egress granted 12 Burglar Alarms - 130 Fire Supervisory - 200 and 210 200 Fire supervisory 32 201 Low water pressure 33 202 Low CO2 34 203 Gate valve sensor 35 204 Low water level 36 205 Pump activated 37 206 Pump failure 38 System Troubles - 300 and 310 300 System trouble 39 301 AC loss 3A 302 Low system battery 3B 303 RAM checksum bad 3C 304 ROM checksum 3D 130 Burglary 13 305 System reset 3E 131 Perimeter 14 306 Panel program changed 3F 132 Interior 15 307 Self-test failure 40 133 24-hour 16 308 System shutdown 41 134 Entry/Exit 17 309 Battery test failure 42 135 Day/Night 18 310 Ground fault 43 136 Outdoor 19 311 Battery missing/dead 44 137 Tamper 1A 312 Power supply over current limit 45 138 Near alarm 1B 313 Engineer reset 46 139 Intrusion verified 1C General Alarms - 140 Sounder/Relay Troubles - 320 320 Sounder/relay 47 140 General alarm 1D 321 Bell 1 48 141 Polling loop open 1E 322 Bell 2 49 142 Polling loop short 1F 323 Alarm relay 4A 143 Expansion module failure 20 324 Trouble relay 4B 144 Sensor tamper 21 325 Reversing relay 4C 145 Expansion module tamper 22 326 Notification appliance chk. #3 4D 146 Silent burglary 23 327 Notification appliance chk. #4 4E 147 Sensor supervision failure 24 24-hour Non-burglary - 150 and 160 System Peripheral Troubles - 330 and 340 330 System peripheral 4F 150 24-hour non-burglary 25 331 Polling loop open 50 151 Gas detected 26 332 Polling loop short 51 152 Refrigeration 27 333 Expansion module failure 52 153 Loss of heat 28 334 Repeater failure 53 Paradox Magellan Systems 41 CID# Reporting Code Programming Value 335 Local printer paper out 54 336 Local printer failure 55 337 Expansion module DC loss 56 338 Expansion module low battery 57 339 Expansion module reset 58 341 Expansion module tamper 59 342 Expansion module AC loss 5A 343 Expansion module self-test fail 5B 344 RF receiver jam detect 5C Communication Troubles - 350 and 360 Reporting Code Programming Value 408 Quick arm 81 409 Keyswitch open/close 82 Remote Access - 410 411 Call back request made 83 412 Success - download access 84 413 Unsuccessful access 85 414 System shutdown 86 415 Dialer shutdown 87 416 Successful upload 88 Access Control - 420 and 430 350 Communication 5D 351 Telco 1 fault 5E 352 Telco 2 fault 5F 353 Long range radio 60 354 Fail to communicate 61 355 Loss of radio supervision 62 356 Loss of central polling 63 357 Long range radio VSWR problem 64 Protection Loop Troubles - 370 421 Access denied 89 422 Access report by user 8A 423 Forced access 8B 424 Egress denied 8C 425 Egress granted 8D 426 Access door propped open 8E 427 Access point door status monitor trouble 8F 428 Access point request to exit 90 429 Access program mode entry 91 370 Protection loop 65 430 Access program mode exit 92 371 Protection loop open 66 431 Access threat level change 93 372 Protection loop short 67 432 Access relay/trigger fail 94 373 Fire trouble 68 433 Access RTE shunt 95 374 Exit error alarm 69 434 Access DSM shunt 96 375 Panic zone trouble 6A 376 Hold-up zone trouble 6B 377 Swinger trouble 6C 378 Cross-zone trouble 6D Sensor Troubles - 380 and 390 Arming - 440 and 450 441 Armed Stay 97 442 Keyswitch armed Stay 98 450 Exception open/close 99 451 Early open/close 9A 380 Sensor trouble 6E 452 Late open/close 9B 381 Loss of supervision - RF 6F 453 Failed to open 9C 382 Loss of supervision - RPM 70 454 Failed to close 9D 383 Sensor tamper 71 455 Auto-arm failed 9E 384 RF transmitter low battery 72 456 Partial arm 9F 385 Smoke detector Hi sensitivity 73 457 Exit error (user) A0 386 Smoke detector Low sensitivity 74 458 User on premises A1 387 Intrusion detector Hi sensitivity 75 459 Recent close A2 388 Intrusion detector Low sensitivity 76 389 Sensor self-test failure 77 391 Sensor watch trouble 78 392 Drift compensation error 79 393 Maintenance alert 7A Open/Close - 400 42 CID# 400 Open/Close 7B 401 Open/Close by user 7C 402 Group open/close 7D 403 Automatic open/close 7E 406 Cancel 7F 407 Remote arm/disarm 80 System - 460 461 Wrong code entry A3 462 Legal code entry A4 463 Re-arm after alarm A5 464 Auto-arm time extended A6 465 Panic alarm reset A7 466 Service on/off premises A8 Sounder Relay Disabled - 520 520 Sounder/Relay disabled A9 521 Bell 1 disabled AA 522 Bell 2 disabled AB 523 Alarm relay disabled AC 524 Trouble relay disabled AD Reference & Installation Manual CID# Reporting Code Programming Value 525 Reversing relay disabled AE 526 Notification appliance chk. #3 disabled AF 527 Notification appliance chk. #4 disabled B0 Modules - 530 531 Module added B1 532 Module removed B2 Communication Disables - 550 and 560 551 Dialer disabled B3 552 Radio transmitter disabled B4 Bypasses - 570 570 Zone bypass B5 571 Fire bypass B6 572 24Hr. zone bypass B7 573 Burglary bypass B8 574 Group bypass B9 575 Swinger bypass BA 576 Access zone shunt BB 577 Access point bypass BC Test/Misc. - 600 601 Manual trigger test BD 602 Periodic test report BE 603 Periodic RF transmission BF 604 Fire test C0 605 Status report to follow C1 606 Listen-in to follow C2 607 Walk test mode C3 608 Periodic test - system trouble present C4 609 Video transmitter active C5 611 Point test OK C6 612 Point not tested C7 613 Intrusion zone walk tested C8 614 Fire zone walk tested C9 615 Panic zone walk tested CA 616 Service request CB 621 Event log reset CC 622 Event log 50% full CD 623 Event log 90% full CE 624 Event log overflow CF 625 Time/Date reset D0 626 Time/Date inaccurate D1 627 Program mode entry D2 628 Program mode exit D3 629 32-hour event log marker D4 630 Schedule change D5 631 Exception schedule change D6 632 Access schedule change D7 654 System inactivity D8 Paradox Magellan Systems 43 Index Numerics 001 to 016 .................................................................15–18 021 to 036 ...........................................................19, 21, 34 058 .................................................................................19 059 .................................................................................19 060 .................................................................................15 061 .................................................................................15 062 .................................................................................23 063 .................................................................................24 064 .................................................................................22 065 .................................................................................18 066 .................................................................................32 067 .................................................................................17 068 .................................................................................34 069 .................................................................................34 070 .................................................................................33 071 .................................................................................32 072 .................................................................................38 073 .................................................................................32 074 .................................................................................38 075 .................................................................................18 076 .................................................................................31 078 .................................................................................26 079 .................................................................................30 080 .................................................................................23 084 .................................................................................32 085 .................................................................................22 086 .................................................................................34 087 .................................................................................34 088 .................................................................................34 089 .................................................................................34 090 .....................................................................14, 35, 36 091 ...........................................................................26, 35 092 ...........................................................................22, 23 093 .....................................................................23, 33, 36 094 .............................................................. 18, 24, 25, 33 095 .......................................................................9, 18, 23 096 .............................................................. 19, 24, 33, 36 098 .....................................................................31, 32, 38 099 ...........................................................................29, 31 100 .................................................................................31 101 .................................................................................31 102 .................................................................................31 103 .................................................................................24 105 .................................................................................30 106 .................................................................................30 107 .................................................................................30 108 .................................................................................38 109 .................................................................................38 111 .................................................................................29 112 .................................................................................29 113 .................................................................................29 114 .................................................................................29 115 .................................................................................38 116 .................................................................................30 119 .................................................................................30 120 to 123 .......................................................................27 124 ...........................................................................22, 27 125 .................................................................................27 126 to 129 .......................................................................27 44 130 .................................................................................27 131 to 134 .......................................................................27 135 to 138 .......................................................................27 139 .................................................................................27 140 .................................................................... 14, 27, 28 141 to 144 .......................................................................28 145 to 148 .......................................................................28 149 .................................................................................28 150 .......................................................................... 28, 29 151 .......................................................................... 28, 29 154 .......................................................................... 28, 29 155 .................................................................................28 161 to 176 .......................................................................20 173 .................................................................................28 174 .......................................................................... 28, 29 175 .................................................................................29 176 .................................................................................29 180 .................................................................................36 181 .................................................................................14 182 .................................................................................14 187 .................................................................................16 190 .................................................................................16 200 .................................................................................14 201 .......................................................................... 19, 36 210 .................................................................................35 211 .................................................................................35 212 .................................................................................35 213 .................................................................................35 214 .................................................................................35 215 .................................................................................35 216 .................................................................................35 217 .................................................................................35 218 .................................................................................25 232 .................................................................................19 233 .................................................................................19 234 .................................................................................19 240 .................................................................................35 241 .................................................................................35 242 .................................................................................35 243 .......................................................................... 21, 35 246 .................................................................................21 247 .................................................................................21 248 .................................................................................21 24Hr. zone types 24Hr. Burglary Zones .................................................16 24Hr. Buzzer Zones ...................................................16 24Hr. Freeze Zones ...................................................17 24Hr. Gas Zones .......................................................17 24Hr. Heat Zones ......................................................17 24Hr. Hold-up Zones ..................................................16 24Hr. Water Zones ....................................................17 Standard 24Hr. Fire Zones ..........................................16 290 .................................................................................24 291 .................................................................................24 292 .................................................................................24 293 .................................................................................24 295 .................................................................................25 296 .......................................................................... 21, 25 32 ...................................................................................16 Reference & Installation Manual A AC failure report code .......................................................33 AC power ..........................................................................7 AC power failure warning ..................................................36 Account number ...............................................................30 Activation event (onboard) .................................................34 Activation event (wireless) .................................................35 Adding ..............................................................................6 Adding a zone ....................................................................4 Ademco Contact ID ..........................................................31 Ademco slow ...................................................................30 Alarm options Bell Cut-off timer ........................................................24 Check-in Supervision .................................................24 Panic alarms .............................................................26 Tamper Recognition options .......................................24 Wireless PGM Supervision .........................................25 Wireless Transmitter Supervision options .....................24 Alarm types .....................................................................17 Alarms options Backup Alarm Reporting Option ..................................25 Alternate dial options ........................................................31 Answer options, Panel ......................................................38 Answering machine override ..............................................38 Arming options Auto-arm options .......................................................23 Bell Squawk on Arm/Disarm with Remote Control .........23 Closing Delinquency Timer .........................................23 Exit delay ..................................................................23 Exit Delay Termination ...............................................23 Follow Zone switches to Entry Delay 2 .........................23 No Exit Delay when Arming with Remote Control ..........23 No Movement Auto-arming .........................................22 One-touch arming ......................................................23 Regular Arming switches to Force Arming ....................22 Regular Arming switches to Stay Arming ......................22 Stay Arm Siren Delay .................................................23 Stay Arming switches to Force Arming .........................22 Timed Auto-arming ....................................................22 Arming report codes .........................................................27 Assigning remote controls .................................................20 Assigning wireless doorbells ..............................................19 Assigning Wireless Keypads ..............................................21 Assigning wireless repeaters .............................................21 Assigning wireless zones ..................................... 19, 21, 34 Auto-arm timer .................................................................22 Auto-arming options .........................................................23 Auto-test report ................................................................32 Auto-zone Shutdown ........................................................17 Auto-zone Shutdown counter .............................................17 Auxiliary ............................................................................7 Call back feature ............................................................. 38 Call direction ................................................................... 31 Central station telephone numbers .................................... 29 Check-in Supervision time ................................................ 24 Closing Delinquency Timer ............................................... 23 Code length .................................................................... 14 Codes Code length .............................................................. 14 Duress code ............................................................. 14 Installer code ............................................................ 14 Maintenance code ..................................................... 14 System master code .................................................. 14 Connections AC power ................................................................... 7 Backup battery ............................................................ 7 DC power ................................................................... 7 Hardwire zone ............................................................ 9 Paradox Memory Key .......................................... 10, 12 PGMs ........................................................................ 8 Telephone Line ........................................................... 8 UIP-256 ................................................................... 10 WinLoad .................................................................. 10 X10 ......................................................................... 10 Console account number .................................................. 30 Console audible trouble warning ....................................... 36 Console tamper supervision ............................................. 36 Console telephone numbers ............................................. 29 Contact ID ...................................................................... 31 Cut-off, Bell ..................................................................... 24 Backup Alarm Reporting Option .........................................25 Backup telephone number .................................................29 Battery pack ......................................................................7 Bell Cut-off timer ..............................................................24 Bell squawk on Arm/Disarm with Remote Control ................23 Bypass option ..................................................................17 Bypass options, Supervision ..............................................24 Bypass options, Tamper ...................................................25 Paradox Magellan Systems Date entry, single digit ...................................................... 13 Daylight savings time ....................................................... 36 DC Power ......................................................................... 7 Deactivation event (onboard) ............................................ 34 Deactivation event (wireless) ............................................ 35 Definitions, zone 24Hr. Burglary Zones ................................................ 16 24Hr. Buzzer Zones .................................................. 16 24Hr. Freeze Zones .................................................. 17 24Hr. Gas Zones ...................................................... 17 24Hr. Heat Zones ...................................................... 17 24Hr. Hold-up Zones ................................................. 16 24Hr. Water Zones .................................................... 17 Delayed Fire Zones ................................................... 16 Entry Delay 1 ............................................................ 15 Entry Delay 2 ............................................................ 15 Follow Zones ............................................................ 15 Follow/Stay Zones .................................................... 16 Instant Zones ............................................................ 16 Instant/Stay Zones .................................................... 16 Standard 24Hr. Fire Zones ......................................... 16 Delay before Alarm Report Code Transmission ................... 18 Delay between dialing attempts ......................................... 31 Delay Power Failure Report .............................................. 33 Delay, Alarm Transmission ............................................... 18 Delay, Intellizone ............................................................. 18 Delay, PGM (onboard) ..................................................... 34 Delay, PGM (wireless) ..................................................... 35 Delay, Remote Panic Disarm Lock .................................... 26 Delay, Stay Delay Zones .................................................. 18 Delayed Fire Zones ......................................................... 16 45 Deleting ............................................................................6 Deleting wireless zones ....................................................19 Dialer & Reporting Settings Alternate Dial Option ..................................................31 Auto-test report .........................................................32 Console account number ............................................30 Console telephone numbers .......................................29 Delay between dialing attempts ...................................31 Dialing method ..........................................................32 Disarm reporting options ............................................33 event call direction .....................................................31 Force Dial Option ......................................................31 Power failure report delay ...........................................33 Pulse ratio ................................................................32 Recent close delay ....................................................32 Report Codes ............................................................27 Reporting formats ......................................................30 Switch to pulse dialing ................................................32 TLM .........................................................................32 Zone restore report options .........................................33 Dialing method .................................................................32 Direct connect ...................................................................8 Disarm reporting options ...................................................33 Disarming report codes .....................................................27 Display, trouble ................................................................36 Doorbell tones .................................................................19 Duress code ....................................................................14 Entry Delay 1 ...................................................................15 Entry Delay 2 ...................................................................15 EOL zones ......................................................................18 Event Onboard PGM activation ............................................34 Onboard PGM deactivation .........................................34 Wireless PGM activation ............................................35 Wireless PGM deactivation .........................................35 Event call direction ...........................................................31 Exit Delay Termination ......................................................23 Intellizone Delay timer ......................................................18 Line plug connect ...............................................................8 Location ..........................................................................11 Lock system master code ..................................................14 Lock, installer ...................................................................36 Maintenance code ............................................................14 Master code ....................................................................14 Master code lock ..............................................................14 Master code reset ............................................................14 Memory Key ....................................................................10 Memory Key programming ................................................13 Mounting Magellan ...........................................................11 No Exit Delay when Arming with Remote Control .................23 No Movement Auto-arming ................................................22 No Movement timer ..........................................................22 Normal state, PGM ...........................................................35 Number of rings ...............................................................38 Onboard programmable outputs Activation event .........................................................34 Deactivation event .....................................................34 Options ...........................................................................21 Options, zone Alarm types ...............................................................17 Auto-zone Shutdown ..................................................17 Bypass option ...........................................................17 Delay before Alarm Report Code Transmission .............18 Force Zones ..............................................................18 Intellizone .................................................................17 Output ...............................................................................7 Outputs .............................................................................6 Overview, zone programming ............................................15 Feature select programming ..............................................13 Fire zone types Delayed Fire Zones ...................................................16 Standard 24Hr. Fire Zones .........................................16 FM tuner option ...............................................................36 Follow Zone switches to Entry Delay 2 ...............................23 Follow Zones ...................................................................15 Follow/Stay Zones ...........................................................16 Force Dial Option .............................................................31 Force Zones ....................................................................18 Formats, reporting ............................................................30 Hardwire zone connections .................................................9 Indentifier, panel ..............................................................38 Installer code ...................................................................14 Installler lock ...................................................................36 Instant Zones ..................................................................16 Instant/Stay Zones ...........................................................16 Intellizone ........................................................................17 46 Pack, backup battery ..........................................................7 Pager reporting message ..................................................29 Pager telephone number ...................................................29 Panel answer options (WinLoad) Answering machine override .......................................38 Number of rings .........................................................38 Panel identifier .................................................................38 Panic Alarm types ............................................................26 Panic alarms ....................................................................26 Password, PC ..................................................................38 PC password ...................................................................38 PC telephpone number .....................................................38 PGM (Control Panel) Deactivation Event .....................................................34 PGM Delay ...............................................................34 PGMs .............................................................................34 PMC-3 ............................................................................10 Power failure report delay .................................................33 Power, AC .........................................................................7 Power, DC .........................................................................7 Programmable outputs ........................................................8 Reference & Installation Manual Normal state ..............................................................35 Onboard PGM delay ..................................................34 Setting PGM1 & PGM2 Function .................................34 Wireless PGM delay ...................................................35 X10 option ................................................................35 Programming methods Feature select programming .......................................13 Paradox Memory Key .................................................13 Single digit data entry .................................................13 Through the built-in keypads .......................................13 WinLoad ...................................................................13 Programming zones .........................................................15 Pulse ratio .......................................................................32 Ratio, pulse .....................................................................32 Recent close delay ...........................................................32 Regular arming switches to Force arming ...........................22 Regular arming switches to Stay arming .............................22 Remote controls Assigning ..................................................................20 Programming buttons .................................................20 Remote controls, assigning ...............................................20 Repeater .........................................................................21 Report codes AC failure ..................................................................33 Arming ......................................................................27 Disarming .................................................................27 Special .....................................................................28 Special alarm ............................................................27 Special arming ...........................................................27 Special disarming ......................................................27 System trouble ..........................................................28 System trouble restore ...............................................28 Test ..........................................................................32 Zone alarm ................................................................27 Zone alarm restore .....................................................27 Zone tamper ..............................................................28 Zone tamper restore ...................................................28 Report formats Ademco Contact ID format ..........................................31 Ademco slow format ...................................................30 SESCOA format ........................................................30 SIA FSK format .........................................................31 Silent Knight fast format ..............................................30 Standard Pulse format ................................................31 Reporting & Dialer Settings Account number ........................................................30 Alternate dial options ..................................................31 Auto-test report ..........................................................32 Console telephone numbers .......................................29 Delay between dialing attempts ...................................31 Dialing method ..........................................................32 Disarm report options .................................................33 Event call direction .....................................................31 Force Dial Option .......................................................31 Power Failure report delay ..........................................33 Pulse ratio .................................................................32 Recent Close Delay ...................................................32 Report Codes ............................................................27 Reporting formats ......................................................30 Switch to Pulse dialing ................................................32 TLM .........................................................................32 Zone Restore Report options ......................................33 Paradox Magellan Systems Reset software ................................................................ 36 Reset system master code ............................................... 14 RF Interference Detection ................................................. 33 RF Jamming Supervision ................................................. 33 Service telephone number ................................................ 30 SESCOA ........................................................................ 30 Setting PGM 1 & PGM2 Function ...................................... 34 Shutdown, Auto-zone ....................................................... 17 SIA FSK ......................................................................... 31 Silent Knight Fast ............................................................ 30 Single digit data entry method ........................................... 13 Software reset ................................................................. 36 Special alarm report codes ............................................... 27 Special arming report codes ............................................. 27 Special disarming report codes ......................................... 27 Special keys for telephone nos. ......................................... 29 Special report codes ........................................................ 28 Standard 24Hr. Fire Zones ............................................... 16 Stay Arm Siren Delay ....................................................... 23 Stay arming switches to Force arming ............................... 22 Stay zone types Follow/Stay Zones .................................................... 16 Instant/Stay Zones .................................................... 16 Supervision Check-in .................................................................. 24 Console tamper ........................................................ 36 Wireless PGM .......................................................... 25 Wireless transmitters ................................................. 24 Supervision Bypass options .............................................. 24 Switch to Pulse dialing ..................................................... 32 System master code ........................................................ 14 System master code lock ................................................. 14 System master code reset ................................................ 14 System settings AC power failure warning ........................................... 36 Console audible trouble warning ................................. 36 Console tamper supervision ....................................... 36 Daylight savings time ................................................. 36 FM tuner option ........................................................ 36 Installer lock ............................................................. 36 Software reset .......................................................... 36 System trouble report codes ....................................... 28, 29 System trouble restore report codes .................................. 28 Tamper Bypass options .................................................... 25 Tamper Recognition options ............................................. 24 Tamper supervision, console ............................................ 36 Telephone line connection Direct connect ............................................................ 8 Line plug connect ........................................................ 8 Telephone Line Monitoring (TLM) ...................................... 32 Telephone numbers ......................................................... 29 Central station .......................................................... 29 Pager ...................................................................... 29 PC ........................................................................... 38 Service .................................................................... 30 Voice Message ......................................................... 29 Test report code .............................................................. 32 Test Report, Automatic ..................................................... 32 Timed Auto-arming .......................................................... 22 47 Timers Alarm Transmission ...................................................18 Auto-arm ..................................................................22 Auto-zone Shutdown ..................................................17 Bell Cut-off ................................................................24 Check-in Supervision .................................................24 Closing Delinquency ..................................................23 Delay between dialing attempts ...................................31 Entry Delay 1 ............................................................15 Entry Delay 2 ............................................................15 Exit delay ..................................................................23 Intellizone .................................................................18 No Movement ...........................................................22 Onboard PGM delay ..................................................34 Power failure report delay ...........................................33 Recent close .............................................................32 TLM fail ....................................................................32 Wireless PGM delay ..................................................35 TLM fail timer ...................................................................32 Tones, doorbell ................................................................19 Transmitter supervision options .........................................24 Trouble display ................................................................36 Trouble, audible warning ...................................................36 User codes Duress code .............................................................14 Installer code ............................................................14 Maintenance code .....................................................14 System master code ..................................................14 User code length .......................................................14 Viewing ...........................................................................19 Viewing transmitter signal strength .....................................19 Voice message repetitions ................................................30 Voice message telephone numbers ...................................29 Wall plate ........................................................................11 WinLoad .........................................................................13 WinLoad settings Call back feature .......................................................38 Panel answer options .................................................38 Panel identifier ..........................................................38 PC password ............................................................38 PC telephone number ................................................38 Wireless Keypad Supervision Options ................................25 Wireless Module Trouble Report Codes .......................28, 29 Wireless PGM Deactivation Event .....................................................35 PGM Delay ...............................................................35 Wireless PGM Supervision Options ....................................25 Wireless programmable outputs Activation event .........................................................35 Deactivation event .....................................................35 Wireless programming Assigning remote controls ..........................................20 Assigning wireless doorbells .......................................19 Assigning wireless zones .....................................19, 34 Deleting wireless zones ..............................................19 Programming remote control buttons ...........................20 Viewing signal strength ..............................................19 48 Wireless Repeater Supervision Options ....................... 21, 25 Wireless Transmitter Supervision options ............................24 Wireless zones become hardwire .......................................18 Wirless doorbell tones ......................................................19 X10 connections ..............................................................10 X10 PGM option ...............................................................35 Zone alarm report codes ...................................................27 Zone alarm restore report codes ........................................27 Zone definitions 24Hr. Burglary Zones .................................................16 24Hr. Buzzer Zones ...................................................16 24Hr. Freeze Zones ...................................................17 24Hr. Gas Zones .......................................................17 24Hr. Heat Zones ......................................................17 24Hr. Hold-up Zones ..................................................16 24Hr. Water Zones ....................................................17 Delayed Fire Zones ....................................................16 Entry Delay 1 ............................................................15 Entry Delay 2 ............................................................15 Follow Zones .............................................................15 Follow/Stay Zones .....................................................16 Instant Zones ............................................................16 Instant/Stay Zones .....................................................16 Standard 24Hr. Fire Zones ..........................................16 Zone options Alarm types ...............................................................17 Auto-zone Shutdown ..................................................17 Bypass option ...........................................................17 Delay before Alarm Code Transmission .......................18 Force Zones ..............................................................18 Intellizone .................................................................17 Stay Delay Zones ......................................................18 Zone programming ...........................................................15 Zone restore report options ...............................................33 Zone tamper report codes .................................................28 Zone tamper restore report codes ......................................28 Zone, hardwire ...................................................................9 Reference & Installation Manual WARRANTY EQUIPMENT MAINTENANCE FACILITY Paradox Security Systems Ltd. (“Seller”) warrants its products to be free from defects in materials and workmanship under normal use for a period of one year. Except as specifically stated herein, all express or implied warranties whatsoever, statutory or otherwise, including without limitation, any implied warranty of merchantability and fitness for a particular purpose, are expressly excluded. Because Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller, Seller cannot guarantee the performance of the security system and shall not be responsible for circumstances resulting from the product’s inability to operate. Seller obligation and liability under this warranty is expressly limited to repairing or replacing, at Seller's option, any product not meeting the specifications. Returns must include proof of purchase and be within the warranty period. In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental, including without limitation, any damages for lost profits stolen goods, or claims by any other party, caused by defective goods or otherwise arising from the improper, incorrect or otherwise faulty installation or use of the merchandise sold. If you experience trouble with this telephone equipment, please contact facility indicated below for information on obtaining service or repairs. The telephone company may ask that you disconnect this equipment from network until problem is corrected or until you are sure that the equipment is not malfunctioning. Notwithstanding the preceding paragraph, the Seller’s maximum liability will be strictly limited to the purchase price of the defective product. Your use of this product signifies your acceptance of this warranty. BEWARE: Dealers, installers and/or others selling the product are not authorized to modify this warranty or make additional warranties that are binding on the Seller. © 2006 Paradox Security Systems Ltd. All rights reserved. Magellan is a trademark or registered trademark of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries. Windows® is a registered trademark of Microsoft Corporation. All rights reserved. Specifications may change without prior notice. FCC PART 15, WARNINGSINFORMATION TO USER This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to equipment intermittently, the user is encouraged to try to correct the interference by one or more of the following measures: (1) re orient or relocate the receiving antenna; (2) increase the separation between the equipment and receiver; (3) connect the equipment to an outlet on a circuit other than the one to which the receiver is connected, or (4) consult the dealer or an experienced radio/tv technician for assistance. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifications not expressly approved by PARADOX SECURITY SYSTEMS could void the user's authority to operate the equipment. UL WARNINGS IMPORTANT INFORMATION IMPORTANT INFORMATION This equipment should be installed in accordance with Chapter 11 of the National Fire Alarm Code, ANSI/NFPA 72, (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269). This equipment complies with Part 68 of the FCC rules subpart D and CS-03. Inside the cover of this equipment is a label that contains, among other information, the FCC registration number of this equipment. Each console is intended to be checked by a technician at least once every three years. FCC WARNINGS NOTIFICATION TO TELEPHONE COMPANY Upon request, customer shall notify telephone company of particular line to which the connection will be made, and provide the FCC registration number and the ringer equivalence of the protective circuit. FCC REGISTRATION NUMBER:5A7AL01BMG-61606130 RINGER EQUIVALENCE NUMBER:0.1B (U.S. & Canada) USOC JACK:RJ31X (USA), CA31A (CANADA) TELEPHONE CONNECTION REQUIREMENTS Except for telephone company provided ringers, all connections to the telephone network shall be made through standard plugs and telephone company provided jacks, or equivalent, in such a manner as to allow for easy, immediate disconnection of terminal equipment. Standard jacks shall be so arranged that, if plug connected thereto is withdrawn, no interference to operation of equipment at customer's premises which remains connected to telephone network shall occur by reason of such withdrawal. INCIDENCE OF HARM Should terminal equipment/protective circuitry cause harm to telephone network, telephone company shall, where practicable, notify customer that temporary disconnection of service may be required; however, where prior notice is not practicable, the telephone company may temporarily discontinue service if action is deemed reasonable in circumstances. In case of temporary discontinuance, telephone company shall promptly notify customer and will be given opportunity to correct the situation. CHANGES IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES The telephone company may make changes in its communication facilities, equipment operations or procedures, where such actions are reasonably required and proper in its business. Should any such changes render customer's terminal equipment incompatible with the telephone company facilities, the customer shall be given adequate notice to effect the modifications to maintain uninterrupted service. GENERAL This equipment shall not be used on coin telephone lines. Connection to party line service is subject to state tariffs. LIMITATIONS OF ALARM SYSTEMS It must be understood that while your Paradox alarm system is highly advanced and secure, it does not offer any guaranteed protection against burglary, fire or other emergency (fire and emergency options are only available on certain Paradox models). This is due to a number of reasons, including by not limited to inadequate or improper installation/positioning, sensor limitations, battery performance, wireless signal interruption, inadequate maintenance or the potential for the system or telephone lines to be compromised or circumvented. As a result, Paradox does not represent that the alarm system will prevent personal injury or property damage, or in all cases provide adequate warning or protection. Your security system should therefore be considered as one of many tools available to reduce risk and/or damage of burglary, fire or other emergencies, such other tools include but are not limited to insurance coverage, fire prevention and extinguish devices, and sprinkler systems. We also strongly recommend that you regularly maintain your security systems and stay aware of new and improved Paradox products and developments. WARNINGS FOR CONNECTIONS TO NON-TRADITIONAL TELEPHONY (e.g. VoIP) Paradox alarm equipment was designed to work effectively around traditional telephone systems. For those customers who are using a Paradox alarm panel connected to a non-traditional telephone system, such as "Voice Over Internet Protocol" (VoIP) that converts the voice signal from your telephone to a digital signal traveling over the Internet, you should be aware that your alarm system may not function as effectively as with traditional telephone systems. For example, if your VoIP equipment has no battery back-up, during a power failure your system's ability to transmit signals to the central station may be compromised. Or, if your VoIP connection becomes disabled, your telephone line monitoring feature may also be compromised. Other concerns would include, without limitation, Internet connection failures which may be more frequent than regular telephone line outages. We therefore strongly recommend that you discuss these and other limitations involved with operating an alarm system on a VoIP or other non-traditional telephone system with your installation company. They should be able to offer or recommend measures to reduce the risks involved and give you a better understanding. RINGER EQUIVALENCE NUMBER (REN) The ren is useful to determine the quantity of devices that you may connect to your telephone line and still have all of those devices ring when your telephone number is called. In most, but not all areas, sum of the ren's of all devices connected to one line should not exceed five (5.0). To be certain of the number of devices that you may connect to your line, you may want to contact your local telephone company. Paradox Magellan Systems 49 For technical support in Canada or the U.S., call 1-800-7911919, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST. For technical support outside Canada and the U.S., call 00-1-450491-7444, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST. Please feel free to visit our website at www.paradox.com. paradox.com Printed in Canada - 01/2007 MAGELLAN-EI07
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 52 Page Mode : UseOutlines XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:9cf8cfc5-9ca9-4a3d-a2fd-9b880487ae6c Producer : Acrobat Distiller 6.0 (Windows) Modify Date : 2007:02:22 11:20:43-05:00 Create Date : 2003:04:02 13:27:54Z Creator Tool : FrameMaker 7.2 Metadata Date : 2007:02:22 11:20:43-05:00 Document ID : uuid:f0702cec-7d6a-46e6-ac5e-25b42cecb0b2 Format : application/pdf Title : MAGELLAN MG-6160 & MG-6160 : Installation Manual Creator : Author : Keywords : [English], MAGELLAN-EI07EXIF Metadata provided by EXIF.tools